All MIBs › OMNI-gx2RX200-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 RX200 200 MHz optical receiver card in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2RX200-MIB?
This MIB manages the Cisco (originally Scientific-Atlanta) GX2 RX200 200 MHz optical receiver card, a module in GX2-series HFC optical nodes responsible for converting downstream optical signals into RF for distribution over the coax plant. No sample objects were provided in this batch, but receiver-card MIBs in this OMNI family typically expose module presence, received optical power level, RF output level, and an operational/fault status. Its purpose is hardware status monitoring for signal quality: tracking received optical power and card operational status helps detect a degraded fiber link, a failing laser/receiver, or a card fault before it causes visible downstream video/data quality problems for subscribers. It belongs to Cisco/Scientific-Atlanta's proprietary GX2 optical node MIB family rather than any IETF standard, working alongside sibling power-supply and expansion-module MIBs to give a full node picture. It is deployed in cable operator HFC networks on GX2 optical nodes at fiber-to-coax conversion points in the outside plant, monitored through the OMNI-gx2RX200-MIB MIB.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2RX200-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 RX200 200 MHz optical receiver card)
Monitoring Examples
An operator would poll the RX200 card's received optical power level and operational status objects (per the OMNI-gx2 module pattern) to confirm the receiver is within its specified optical input range and reporting no fault. A steadily declining optical power reading typically signals fiber attenuation or connector degradation upstream of the node and would prompt a plant inspection before signal loss occurs. Because no object names were available in this batch, exact object names cannot be confirmed and this description reflects the module's known general purpose within the GX2 product line.
What Can Be Monitored
- received optical power level
- RF output level
- card operational/fault status
- module presence
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Rx200 | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapRX200ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.6.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapRX200ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.6.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapRX200OpticalPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.6.0.3 | This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200ModuleTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.6.0.4 | This trap is issued when the RX200 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200FanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.6.0.5 | This trap is issued when the RX200 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200Plus12CurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.6.0.6 | This trap is issued when the RX200 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200Boot0Alarm | 1.3.6.1.4.1.1166.6.1.2.6.0.7 | This trap is issued when the RX200 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200Boot1Alarm | 1.3.6.1.4.1.1166.6.1.2.6.0.8 | This trap is issued when the RX200 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.6.0.9 | This trap is issued when the RX200 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.6.0.10 | This trap is issued when the RX200 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.6.0.11 | This trap is issued when the RX200 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200CalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.6.0.12 | This trap is issued when the RX200 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200DefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.6.0.13 | This trap is issued when the RX200 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200ModeAlarm | 1.3.6.1.4.1.1166.6.1.2.6.0.14 | This trap is issued when the RX200 Modules mode is changed from normal to off or off to normal. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200OutputSwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.6.0.15 | This trap is issued when the RX200 Module's output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRX200SideStatusAlarm | 1.3.6.1.4.1.1166.6.1.2.6.0.16 | This trap is issued when one of the RX200 Module's outputs are turned on or off. | ||
| gx2Rx200Descriptor | 1.3.6.1.4.1.1166.6.1.2.6.1 | |||
| gx2Rx200AnalogTable | 1.3.6.1.4.1.1166.6.1.2.6.2 | not-accessible | This table contains gx2Rx200 specific parameters with nominal and current values. | |
| gx2Rx200AnalogEntry | 1.3.6.1.4.1.1166.6.1.2.6.2.1 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT rxgx2Rx200AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.6.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR rxlabelModTemp | 1.3.6.1.4.1.1166.6.1.2.6.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR rxuomModTemp | 1.3.6.1.4.1.1166.6.1.2.6.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO rxmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.6.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.6.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.6.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.6.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.6.2.1.8 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rxstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.6.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rxminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.6.2.1.10 | Float | read-only | The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.6.2.1.11 | Float | read-only | The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rxalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.6.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR rxlabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.6.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR rxuomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.6.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO rxmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.6.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.6.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.6.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.6.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxcurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.6.2.1.19 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rxstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.6.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rxminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.6.2.1.21 | Float | read-only | The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.6.2.1.22 | Float | read-only | The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rxalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.6.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR rxlabel12Volt | 1.3.6.1.4.1.1166.6.1.2.6.2.1.24 | DisplayString | read-only | The value of this object provides the label of the 12v Current Analog parameter. |
| STR rxuom12Volt | 1.3.6.1.4.1.1166.6.1.2.6.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO rxmajorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.6.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxmajorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.6.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxminorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.6.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxminorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.6.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxcurrentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.6.2.1.30 | Float | read-only | The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rxstateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.6.2.1.31 | INTEGER | read-only | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rxminValue12Volt | 1.3.6.1.4.1.1166.6.1.2.6.2.1.32 | Float | read-only | The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxmaxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.6.2.1.33 | Float | read-only | The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rxalarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.6.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| STR rxlabelOptPower | 1.3.6.1.4.1.1166.6.1.2.6.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR rxuomOptPower | 1.3.6.1.4.1.1166.6.1.2.6.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO rxmajorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.6.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxmajorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.6.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxminorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.6.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxminorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.6.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxcurrentValueOptPower | 1.3.6.1.4.1.1166.6.1.2.6.2.1.41 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rxstateFlagOptPower | 1.3.6.1.4.1.1166.6.1.2.6.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rxminValueOptPower | 1.3.6.1.4.1.1166.6.1.2.6.2.1.43 | Float | read-only | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rxmaxValueOptPower | 1.3.6.1.4.1.1166.6.1.2.6.2.1.44 | Float | read-only | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rxalarmStateOptPower | 1.3.6.1.4.1.1166.6.1.2.6.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| gx2Rx200DigitalTable | 1.3.6.1.4.1.1166.6.1.2.6.3 | not-accessible | This table contains gx2Rx200 specific parameters with nominal and current values. | |
| gx2Rx200DigitalEntry | 1.3.6.1.4.1.1166.6.1.2.6.3.2 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT rxgx2Rx200DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.6.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR rxlabelMode | 1.3.6.1.4.1.1166.6.1.2.6.3.2.2 | DisplayString | read-only | The value of this object provides the label of the RX200's Mode Digital parameter. |
| STR rxenumMode | 1.3.6.1.4.1.1166.6.1.2.6.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rxvalueMode | 1.3.6.1.4.1.1166.6.1.2.6.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rxstateFlagMode | 1.3.6.1.4.1.1166.6.1.2.6.3.2.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rxlabelWavelength | 1.3.6.1.4.1.1166.6.1.2.6.3.2.6 | DisplayString | read-only | The value of this object provides the label of the RX200's Wavelength Digital parameter. |
| STR rxenumWavelength | 1.3.6.1.4.1.1166.6.1.2.6.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rxvalueWavelength | 1.3.6.1.4.1.1166.6.1.2.6.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rxstateFlagWavelength | 1.3.6.1.4.1.1166.6.1.2.6.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rxlabelAttnSetting | 1.3.6.1.4.1.1166.6.1.2.6.3.2.10 | DisplayString | read-only | The value of this object provides the label of the RX200's AttnSetting Digital parameter. |
| STR rxenumAttnSetting | 1.3.6.1.4.1.1166.6.1.2.6.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rxvalueAttnSetting | 1.3.6.1.4.1.1166.6.1.2.6.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db |
| INT rxstateFlagAttnSetting | 1.3.6.1.4.1.1166.6.1.2.6.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rxlabelSwModeSetting | 1.3.6.1.4.1.1166.6.1.2.6.3.2.14 | DisplayString | read-only | The value of this object provides the label of the RX200's Switch Mode Setting Digital parameter. |
| STR rxenumSwModeSetting | 1.3.6.1.4.1.1166.6.1.2.6.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rxvalueSwModeSetting | 1.3.6.1.4.1.1166.6.1.2.6.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rxstateFlagSwModeSetting | 1.3.6.1.4.1.1166.6.1.2.6.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rxlabelSwModeThreshold | 1.3.6.1.4.1.1166.6.1.2.6.3.2.18 | DisplayString | read-only | The value of this object provides the label of the RX200's Switch Mode Threshold Digital parameter. |
| STR rxenumSwModeThreshold | 1.3.6.1.4.1.1166.6.1.2.6.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rxvalueSwModeThreshold | 1.3.6.1.4.1.1166.6.1.2.6.3.2.20 | INTEGER | read-write | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
| INT rxstateFlagSwModeThreshold | 1.3.6.1.4.1.1166.6.1.2.6.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rxlabelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.6.3.2.22 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR rxenumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.6.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rxvalueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.6.3.2.24 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rxstateFlagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.6.3.2.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Rx200StatusTable | 1.3.6.1.4.1.1166.6.1.2.6.4 | not-accessible | This table contains gx2Rx200 specific parameters with nominal and current values. | |
| gx2Rx200StatusEntry | 1.3.6.1.4.1.1166.6.1.2.6.4.3 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT rxgx2Rx200StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.6.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR rxlabelBoot | 1.3.6.1.4.1.1166.6.1.2.6.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT rxvalueBoot | 1.3.6.1.4.1.1166.6.1.2.6.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rxstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.6.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rxlabelFlash | 1.3.6.1.4.1.1166.6.1.2.6.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT rxvalueFlash | 1.3.6.1.4.1.1166.6.1.2.6.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rxstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.6.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rxlabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.6.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT rxvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.6.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rxstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.6.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rxlabelAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.6.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Alarm Data CRC Status parameter. |
| INT rxvalueAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.6.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rxstateflagAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.6.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rxlabelCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.6.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| INT rxvalueCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.6.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rxstateflagCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.6.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rxlabelThermalCompCRC | 1.3.6.1.4.1.1166.6.1.2.6.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| INT rxvalueThermalCompCRC | 1.3.6.1.4.1.1166.6.1.2.6.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rxstateflagThermalCompCRC | 1.3.6.1.4.1.1166.6.1.2.6.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rxlabelHW | 1.3.6.1.4.1.1166.6.1.2.6.4.3.20 | DisplayString | read-only | The value of this object provides the label of the Hardware Status parameter. |
| INT rxvalueHW | 1.3.6.1.4.1.1166.6.1.2.6.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rxstateflagHW | 1.3.6.1.4.1.1166.6.1.2.6.4.3.22 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rxlabelOptSig | 1.3.6.1.4.1.1166.6.1.2.6.4.3.23 | DisplayString | read-only | The value of this object provides the label of the Optical Signal Status parameter. |
| INT rxvalueOptSig | 1.3.6.1.4.1.1166.6.1.2.6.4.3.24 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rxstateflagOptSig | 1.3.6.1.4.1.1166.6.1.2.6.4.3.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Rx200FactoryTable | 1.3.6.1.4.1.1166.6.1.2.6.5 | not-accessible | This table contains gx2Rx200 specific parameters with nominal and current values. | |
| gx2Rx200FactoryEntry | 1.3.6.1.4.1.1166.6.1.2.6.5.4 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT rxgx2Rx200FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.6.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT rxbootControlByte | 1.3.6.1.4.1.1166.6.1.2.6.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT rxbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.6.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT rxbank0CRC | 1.3.6.1.4.1.1166.6.1.2.6.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT rxbank1CRC | 1.3.6.1.4.1.1166.6.1.2.6.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT rxprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.6.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT rxfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.6.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT rxcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.6.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT rxhourMeter | 1.3.6.1.4.1.1166.6.1.2.6.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT rxflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.6.5.4.10 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side A. |
| INT rxflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.6.5.4.11 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side B. |
| STR rxfwRev0 | 1.3.6.1.4.1.1166.6.1.2.6.5.4.12 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 0. |
| STR rxfwRev1 | 1.3.6.1.4.1.1166.6.1.2.6.5.4.13 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 1. |
| gx2Rx200HoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.6.6 | not-accessible | This table contains gx2Rx200 specific parameters with nominal and current values. | |
| gx2Rx200HoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.6.6.5 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT rxgx2Rx200HoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.6.6.5.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| INT rxgx2Rx200HoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.6.6.5.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| INT rxgx2Rx200HoldTimeData | 1.3.6.1.4.1.1166.6.1.2.6.6.5.3 | INTEGER | read-write | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds. |
RFC description
Manages OMNISTAR gx2 RX200 return path receiver modules in HFC networks with device descriptors and network element parameters.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 RX200 200 MHz optical receiver card) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.