All MIBs › OMNI-gx2EDFA-MIB › edfavalueModeSetting
edfavalueModeSetting
Module: OMNI-gx2EDFA-MIB
OID (symbolic): OMNI-gx2EDFA-MIB::edfavalueModeSetting
OID (numeric): 1.3.6.1.4.1.1166.6.1.2.11.3.2.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The value of this object is the current value of the parameter. It is an integer value from 0 to 5 representing the operation mode of the module.
What is edfavalueModeSetting?
The module's current operating mode: power-out-preset(1), power-out-set(2), laser-power-preset(3), laser-power-set(4), constant-gain-preset(5), or constant-gain-set(6). An admin writes this to choose which control loop (output power, laser power, or constant gain) governs the amplifier, and whether it should use a stored factory preset or the operator's own setpoint in edfacurrentValueOPSetting/LPSetting/CGSetting.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.11.3.2.4 snmpwalk -v2c -c public <target> OMNI-gx2EDFA-MIB::edfavalueModeSetting
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.11.3.2.4.1 snmpget -v2c -c public <target> OMNI-gx2EDFA-MIB::edfavalueModeSetting.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.6.1.2.11.3.2.4.1 i <value>
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2EDFA-MIB::edfavalueModeSetting OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1166 | gi | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6 | motproxies | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6.1 | hfc | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2 | hfcDevices | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2.11 | gx2EDFA | GX2HFC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.11.3 | gx2EDFADigitalTable | OMNI-gx2EDFA-MIB |
| 1.3.6.1.4.1.1166.6.1.2.11.3.2 | gx2EDFADigitalEntry | OMNI-gx2EDFA-MIB |
| 1.3.6.1.4.1.1166.6.1.2.11.3.2.4 | edfavalueModeSetting | OMNI-gx2EDFA-MIB |