All MIBs › OMNI-gx2drt4x-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 DRT4X downstream RF transmitter card in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2drt4x-MIB?
OMNI-gx2drt4x-MIB is a vendor-specific SNMP module from Cisco/Scientific-Atlanta for the GX2 DRT4X, a downstream RF transmitter card used in HFC optical node deployments. It exposes hardware status and configuration data for the RF transmitter card, such as per-port transmit levels, card identity, and operational state, rather than general networking or software data. Its key monitoring purpose is hardware health: surfacing whether the card is present and operating normally, and flagging abnormal RF transmit power that could indicate a failing amplifier or transmitter component. It likely shares indexing and structural conventions with a common GX2 chassis/platform MIB used across the OMNI GX2 card family. It is deployed in cable/MSO HFC networks where optical nodes are remotely monitored via SNMP for outside-plant reliability. Engineers can download the OMNI-gx2drt4x-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2drt4x-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRT4X downstream RF transmitter card)
Monitoring Examples
No sample objects were provided, so specific object names cannot be quoted directly. Based on the module's purpose, monitoring would typically center on a per-port RF transmit level and card status table indexed by slot/port, similar to other GX2 line card MIBs. An engineer would poll such data to detect a transmitter port whose output power has drifted out of tolerance, an early sign of amplifier degradation that could disrupt downstream video/data service. The lack of concrete sample objects means this remains a plausible but unverified scenario.
What Can Be Monitored
- card presence/insertion status
- RF transmit power level
- port operational status
- card operating state
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Drt4x | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapdrt4xConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.25.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapdrt4xConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.25.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapdrt4xModulePlus12CurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.3 | This trap is issued when the Module +12V Supply Current goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapdrt4xModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.4 | This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapdrt4xFanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.5 | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapdrt4xFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.6 | This trap is issued when the detects an error during Flash memory operations. | ||
| NTF trapdrt4xBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.7 | This trap is issued when the detects an error while booting from bank 0 or bank 1. | ||
| NTF trapdrt4xFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.8 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapdrt4xAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.9 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapdrt4xCalibrationDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.10 | This trap is issued when the Calibration Data CRC is incorrect. | ||
| NTF trapdrt4xHardwareErrorAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.11 | This trap is issued when hardware is abnormal. | ||
| NTF trapdrt4xOpticalPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.12 | This trap is issued when the optical power is out of range. | ||
| NTF trapdrt4xTECTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.13 | This trap is issued when the TEC Temperature is out of range. | ||
| NTF trapdrt4xTECCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.14 | This trap is issued when the TEC Current is out of range. | ||
| NTF trapdrt4xLaserBiasCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.15 | This trap is issued when the Laser Bias Current is out of range. | ||
| NTF trapdrt4xResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.25.0.16 | This trap is issued when the Factory Default Reset occurs. | ||
| NTF trapdrt4xLaserOnOffInfo | 1.3.6.1.4.1.1166.6.1.2.25.0.17 | This trap is issued when the When the Laser turns on/off. | ||
| gx2drt4xDescriptor | 1.3.6.1.4.1.1166.6.1.2.25.1 | |||
| gx2drt4xAnalogTable | 1.3.6.1.4.1.1166.6.1.2.25.2 | not-accessible | This table contains Gx2drt4x specific analog parameters with nominal,limits and current values. | |
| gx2drt4xAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.25.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2drt4xAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.25.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR drt4xlabelRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.2 | DisplayString | read-only | The value of this object provides the label of the RF Channel A Attenuation Analog parameter. |
| STR drt4xuomRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter. |
| FLO drt4xmajorHighRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xmajorLowRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xminorHighRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. Set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xminorLowRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. Set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xvalueRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.8 | Float | read-write | The value of this object provides the Current value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xstateFlagRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.9 | INTEGER | read-only | The value of this object provides the state of the RF Channel A Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO drt4xminValueRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.10 | Float | read-only | The value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmaxValueRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.11 | Float | read-only | The value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive.which is 31.0 This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xalarmStateRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter. |
| STR drt4xlabelRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.13 | DisplayString | read-only | The value of this object provides the label of the RF Channel B Attenuation Analog parameter. |
| STR drt4xuomRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter. |
| FLO drt4xmajorHighRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xmajorLowRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xminorHighRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xminorLowRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xvalueRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.19 | Float | read-write | The value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xstateFlagRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.20 | INTEGER | read-only | The value of this object provides the state of the RF Channel B Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO drt4xminValueRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.21 | Float | read-only | The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmaxValueRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.22 | Float | read-only | The value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive.which is 31.0 This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xalarmStateRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter. |
| STR drt4xlabelRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.24 | DisplayString | read-only | The value of this object provides the label of the RF Channel C Attenuation Analog parameter. |
| STR drt4xuomRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the RF Channel C Attenuation Analog parameter. |
| FLO drt4xmajorHighRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xmajorLowRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xminorHighRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xminorLowRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xvalueRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.30 | Float | read-write | The value of this object provides the Current value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xstateFlagRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.31 | INTEGER | read-only | The value of this object provides the state of the RF Channel C Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO drt4xminValueRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.32 | Float | read-only | The value of this object provides the minimum value the RF Channel C Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmaxValueRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.33 | Float | read-only | The value of this object provides the maximum value the RF Channel C Attenuation Analog parameter can achive.which is 31.0 This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xalarmStateRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the RF Channel C Attenuation Analog parameter. |
| STR drt4xlabelRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.35 | DisplayString | read-only | The value of this object provides the label of the RF Channel D Attenuation Analog parameter. |
| STR drt4xuomRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the RF Channel D Attenuation Analog parameter. |
| FLO drt4xmajorHighRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xmajorLowRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xminorHighRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xminorLowRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xvalueRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.41 | Float | read-write | The value of this object provides the Current value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xstateFlagRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.42 | INTEGER | read-only | The value of this object provides the state of the RF Channel D Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO drt4xminValueRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.43 | Float | read-only | The value of this object provides the minimum value the RF Channel D Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmaxValueRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.44 | Float | read-only | The value of this object provides the maximum value the RF Channel D Attenuation Analog parameter can achive.which is 31.0 This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xalarmStateRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.25.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the RF Channel D Attenuation Analog parameter. |
| STR drt4xlabelLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.46 | DisplayString | read-only | The value of this object provides the label of the trip point level Analog parameter. |
| STR drt4xuomLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the trip point level Analog parameter. |
| FLO drt4xmajorHighLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the trip point level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xmajorLowLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the trip point level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xminorHighLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the trip point level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xminorLowLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the trip point level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF) |
| FLO drt4xvalueLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.52 | Float | read-only | The value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input level. When trip point mode is ALARM_SWITCH, when optical power level is lower than trip point level (Set by this parameter), trip point alarm will be generated and RF output impedance will be changed to high impedance as >8.2K. This trip point level value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xstateFlagLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.53 | INTEGER | read-only | The value of this object provides the state of the trip point level Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO drt4xminValueLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.54 | Float | read-only | The value of this object provides the minimum value the trip point level Analog parameter can achive. The minimum value is -19dBm This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmaxValueLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.55 | Float | read-only | The value of this object provides the maximum value the trip point level Analog parameter can achive.which is -1dBm This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xalarmStateLaserPowerMonitor | 1.3.6.1.4.1.1166.6.1.2.25.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the trip point level Analog parameter. |
| STR drt4xlabelLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Optical Power Current Analog parameter. |
| STR drt4xuomLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Current Analog parameter. |
| FLO drt4xmajorHighLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmajorLowLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xminorHighLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xminorLowLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xvalueLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.63 | Float | read-only | The value of this object provides the Current value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xstateFlagLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Optical Power Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO drt4xminValueLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.65 | Float | read-only | The value of this object provides the minimum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmaxValueLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.66 | Float | read-only | The value of this object provides the maximum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xalarmStateLaserBiasCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Current Analog parameter. |
| STR drt4xlabelLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Laser TEC Temperature Analog parameter. |
| STR drt4xuomLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser TEC Temperature Analog parameter. |
| FLO drt4xmajorHighLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmajorLowLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xminorHighLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xminorLowLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xvalueLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.74 | Float | read-only | The value of this object provides the Current value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xstateFlagLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Laser TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO drt4xminValueLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.76 | Float | read-only | The value of this object provides the minimum value the Laser TEC Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmaxValueLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.77 | Float | read-only | The value of this object provides the maximum value the Laser TEC Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xalarmStateLaserTECTemperature | 1.3.6.1.4.1.1166.6.1.2.25.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser TEC Temperature Analog parameter. |
| STR drt4xlabelLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.79 | DisplayString | read-only | The value of this object provides the label of the Laser TEC Current Analog parameter. |
| STR drt4xuomLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser TEC Current Analog parameter. |
| FLO drt4xmajorHighLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmajorLowLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xminorHighLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xminorLowLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xvalueLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.85 | Float | read-only | The value of this object provides the Current value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xstateFlagLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.86 | INTEGER | read-only | The value of this object provides the state of the Laser TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO drt4xminValueLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.87 | Float | read-only | The value of this object provides the minimum value the Laser TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmaxValueLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.88 | Float | read-only | The value of this object provides the maximum value the Laser TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xalarmStateLaserTECCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser TEC Current Analog parameter. |
| STR drt4xlabel12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.90 | DisplayString | read-only | The value of this object provides the label of the 12v power supply Current Analog parameter. |
| STR drt4xuom12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.91 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter. |
| FLO drt4xmajorHigh12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.92 | Float | read-only | The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmajorLow12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.93 | Float | read-only | The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xminorHigh12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.94 | Float | read-only | The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xminorLow12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.95 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xvalue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.96 | Float | read-only | The value of this object provides the Current value of the 12v power supply Current parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xstateFlag12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.97 | INTEGER | read-only | The value of this object provides the state of the 12v power supply Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO drt4xminValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.98 | Float | read-only | The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmaxValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.99 | Float | read-only | The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xalarmState12VCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.100 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter. |
| STR drt4xlabelModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.101 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR drt4xuomModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.102 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO drt4xmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.103 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.104 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.105 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.106 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xvalueModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.107 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.108 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO drt4xminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.109 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.110 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.25.2.1.111 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR drt4xlabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.112 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR drt4xuomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.113 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO drt4xmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.114 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.115 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.116 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.117 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xvalueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.118 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.119 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO drt4xminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.120 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO drt4xmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.121 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drt4xalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.25.2.1.122 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| gx2drt4xDigitalTable | 1.3.6.1.4.1.1166.6.1.2.25.3 | not-accessible | This table contains gx2drt4x specific digital parameters with nominal and current values. | |
| gx2drt4xDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.25.3.2 | not-accessible | This list contains digital parameters and descriptions. | |
| INT gx2drt4xDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.25.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR drt4xlabelBaseITUChannel | 1.3.6.1.4.1.1166.6.1.2.25.3.2.2 | DisplayString | read-only | The value of this object provides the label of the Base ITU Channel Digital parameter. |
| STR drt4xenumBaseITUChannel | 1.3.6.1.4.1.1166.6.1.2.25.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. |
| INT drt4xvalueBaseITUChannel | 1.3.6.1.4.1.1166.6.1.2.25.3.2.4 | INTEGER | read-only | The value of this object is the value of the Base ITU Channel. There are 10 possible value: 1-ch20, 2-ch24, 3-ch28, 4-ch32, 5-ch36, 6-ch40, 7-ch44, 8-ch48, 9-ch52, 10-ch56. |
| INT drt4xstateflagBaseITUChannel | 1.3.6.1.4.1.1166.6.1.2.25.3.2.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR drt4xlabelITUChannelSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.6 | DisplayString | read-write | The value of this object provides the label of the ITU Channel Setting Digital parameter. |
| STR drt4xenumITUChannelSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. |
| INT drt4xvalueITUChannelSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.8 | INTEGER | read-write | The value of this object is the value of the ITU Channel Setting. There are 4 possible value: 1-base (base ITU channel), 2-basePlus1 (base ITU Channel + 1), 3-basePlus2 (base ITU Channel + 2), and 4-basePlus3 (base ITU Channel + 3). |
| INT drt4xstateflagITUChannelSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR drt4xlabelOpticalPowerSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Optical Power Setting Digital parameter. This parameter defines the operating power level of the DRT-4X |
| STR drt4xenumOpticalPowerSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT drt4xvalueOpticalPowerSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.12 | INTEGER | read-write | The value of this object is the setting of the Optical Power. There are two possible value: 1-low, and 2-high. |
| INT drt4xstateflagOpticalPowerSetting | 1.3.6.1.4.1.1166.6.1.2.25.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR drt4xlabelLaserControl | 1.3.6.1.4.1.1166.6.1.2.25.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Laser Control Digital parameter. The Laser Control allows the DRT-4X laser to be turned off or on. |
| STR drt4xenumLaserControl | 1.3.6.1.4.1.1166.6.1.2.25.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. |
| INT drt4xvalueLaserControl | 1.3.6.1.4.1.1166.6.1.2.25.3.2.16 | INTEGER | read-write | The value of this object represents the Laser Control. There are two possible values: 1-off, and 2-on. |
| INT drt4xstateflagLaserControl | 1.3.6.1.4.1.1166.6.1.2.25.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR drt4xlabelFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.25.3.2.18 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR drt4xenumFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.25.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT drt4xvalueFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.25.3.2.20 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT drt4xstateflagFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.25.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2drt4xStatusTable | 1.3.6.1.4.1.1166.6.1.2.25.4 | not-accessible | This table contains gx2drt4x specific status parameters with nominal and current values. | |
| gx2drt4xStatusEntry | 1.3.6.1.4.1.1166.6.1.2.25.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2drt4xStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.25.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR drt4xlabelBoot | 1.3.6.1.4.1.1166.6.1.2.25.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status parameter. |
| INT drt4xvalueBoot | 1.3.6.1.4.1.1166.6.1.2.25.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT drt4xstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.25.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR drt4xlabelFlash | 1.3.6.1.4.1.1166.6.1.2.25.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status parameter. |
| INT drt4xvalueFlash | 1.3.6.1.4.1.1166.6.1.2.25.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT drt4xstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.25.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR drt4xlabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.25.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT drt4xvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.25.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT drt4xstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.25.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR drt4xlabelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.25.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT drt4xvalueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.25.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT drt4xstateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.25.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR drt4xlabelCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.25.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Calibration Data CRC parameter. |
| INT drt4xvalueCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.25.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT drt4xstateflagCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.25.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR drt4xlabelHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.25.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Module Hardware Status parameter. |
| INT drt4xvalueHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.25.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT drt4xstateflagHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.25.4.3.19 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2drt4xFactoryTable | 1.3.6.1.4.1.1166.6.1.2.25.5 | not-accessible | This table contains gx2drt4x specific factory setting parameters with nominal and current values. | |
| gx2drt4xFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.25.5.4 | not-accessible | This list contains Factory setting parameters and descriptions. | |
| INT gx2drt4xFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.25.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT drt4xbootControlByte | 1.3.6.1.4.1.1166.6.1.2.25.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT drt4xbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.25.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT drt4xbank1CRC | 1.3.6.1.4.1.1166.6.1.2.25.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT drt4xbank2CRC | 1.3.6.1.4.1.1166.6.1.2.25.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT drt4xprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.25.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT drt4xfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.25.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT drt4xcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.25.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT drt4xhourMeter | 1.3.6.1.4.1.1166.6.1.2.25.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT drt4xflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.25.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 0 flash has been programmed. |
| INT drt4xflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.25.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR drt4xflashBankARev | 1.3.6.1.4.1.1166.6.1.2.25.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR drt4xflashBankBRev | 1.3.6.1.4.1.1166.6.1.2.25.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
| STR drt4xSubAgentRev | 1.3.6.1.4.1.1166.6.1.2.25.5.4.14 | DisplayString | read-only | This object provides the subagent revision of receiver module. |
RFC description
Manages OMNISTAR Digital Return Transmitter 4X module devices in HFC networks with device descriptor and element status monitoring.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRT4X downstream RF transmitter card) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.