All MIBs › OMNI-gx2drt4x-MIB › drt4xvalueLaserTECCurrent
drt4xvalueLaserTECCurrent
Module: OMNI-gx2drt4x-MIB
OID (symbolic): OMNI-gx2drt4x-MIB::drt4xvalueLaserTECCurrent
OID (numeric): 1.3.6.1.4.1.1166.6.1.2.25.2.1.85
Node type: OBJECT-TYPE
Type: Float
Access: read-only
Description: The value of this object provides the Current value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
What is drt4xvalueLaserTECCurrent?
This is the current live reading for laser TEC (thermoelectric cooler) drive current, stored as an IEEE 32-bit floating point number. This is the current the module is drawing to run the thermoelectric cooler; a rising trend can flag a cooler working harder than normal to hold temperature, often due to ambient heat or a failing TEC. It is read-only over SNMP, so it can only be observed, not changed, through this object.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.25.2.1.85 snmpwalk -v2c -c public <target> OMNI-gx2drt4x-MIB::drt4xvalueLaserTECCurrent
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.25.2.1.85.1 snmpget -v2c -c public <target> OMNI-gx2drt4x-MIB::drt4xvalueLaserTECCurrent.1
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRT4X downstream RF transmitter card) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2drt4x-MIB::drt4xvalueLaserTECCurrent OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRT4X downstream RF transmitter card) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1166 | gi | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6 | motproxies | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6.1 | hfc | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2 | hfcDevices | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2.25 | gx2Drt4x | GX2HFC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.25.2 | gx2drt4xAnalogTable | OMNI-gx2drt4x-MIB |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1 | gx2drt4xAnalogEntry | OMNI-gx2drt4x-MIB |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.85 | drt4xvalueLaserTECCurrent | OMNI-gx2drt4x-MIB |