All MIBs › OMNI-gx2RSW1000B-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 RSW1000B 1000 MHz RF switch module in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2RSW1000B-MIB?
OMNI-gx2RSW1000B-MIB is a vendor MIB for the Cisco/Scientific-Atlanta GX2 RSW1000B, a 1000 MHz RF switch module used in HFC optical node deployments to route or protect RF signal paths. It exposes configuration and status objects for the switch module's current path/state and its operating condition within the GX2 chassis. Its principal monitoring role is hardware status of the switch module, letting operators confirm whether the switch is in its expected (e.g., primary vs. protect) position and whether the module itself is healthy, which matters for path-protection schemes in the optical node. It belongs to the OMNI-gx2 family of module MIBs alongside the laser, amplifier, and attenuator modules, sharing a common management framework. It is typically deployed in HFC optical nodes that use RF switching for redundancy or signal routing. Network engineers evaluating or troubleshooting this functionality can download the OMNI-gx2RSW1000B-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2RSW1000B-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 RSW1000B 1000 MHz RF switch module)
Monitoring Examples
No sample object names were provided for this module; in practice an operator would poll the RSW1000B's switch-position and module-status objects within the GX2 chassis tree. An unexpected switch position or a module reporting a fault state would reveal a failed protection switchover or a hardware problem affecting RF path redundancy in the optical node. It is typically monitored alongside the other OMNI-gx2 module MIBs for the same chassis.
What Can Be Monitored
- switch position/state
- module operational status
- path protection status
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Rsw1000b | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapRSW1000bConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.18.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapRSW1000bConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.18.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapRSW1000bRFInputAlarm | 1.3.6.1.4.1.1166.6.1.2.18.0.3 | This trap is issued when the Switch Control signals go out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRSW1000bFanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.18.0.4 | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRSW1000bModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.18.0.5 | This trap is issued when the Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRSW1000bFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.18.0.6 | This trap is issued when the detects an error during Flash memory operations. | ||
| NTF trapRSW1000bBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.18.0.7 | This trap is issued when the detects an error while booting from bank 0 or bank 1. | ||
| NTF trapRSW1000bAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.18.0.8 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapRSW1000bFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.18.0.9 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapRSW1000bInputSwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.18.0.10 | This trap is issued when the RF input switched. | ||
| NTF trapRSW1000bResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.18.0.11 | This trap is issued when the Factory Default Reset occurs. | ||
| NTF trapRSW1000bSecondaryInputActiveAlarm | 1.3.6.1.4.1.1166.6.1.2.18.0.12 | This trap is issued when the scondary input becomes active. | ||
| NTF trapRSW1000bCalibrationDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.18.0.13 | This trap is issued when the calibration data CRC is incorrect. | ||
| gx2Rsw1000bDescriptor | 1.3.6.1.4.1.1166.6.1.2.18.1 | |||
| gx2Rsw1000bAnalogTable | 1.3.6.1.4.1.1166.6.1.2.18.2 | not-accessible | This table contains gx2Rsw1000b specific parameters with nominal and current values. | |
| gx2Rsw1000bAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.18.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2Rsw1000bAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.18.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR rsw1000blabelPriRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Primary RF Input Level Analog parameter. |
| STR rsw1000buomPriRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Primary RF Input Level Analog parameter. For all analog objects for this parameter type, the Unit of Measure is dBmV. |
| FLO rsw1000bmajorHighPriRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.4 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major High alarm value of the Primary RF Input Level Analog parameter. |
| FLO rsw1000bmajorLowPriRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.5 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major Low alarm value of the Primary RF Input Level Analog parameter. |
| FLO rsw1000bminorHighPriRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.6 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Primary RF Input Level Analog parameter. |
| FLO rsw1000bminorLowPriRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.7 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Primary RF Input Level Analog parameter. |
| FLO rsw1000bcurrentValuePriRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.8 | Float | read-only | The value of this object provides the current value of the Primary RF Input Level Analog parameter. |
| INT rsw1000bstateFlagPriRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Primary RF Input Level Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO rsw1000bminValuePriRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.10 | Float | read-only | The value of this object represents a gauge minimum limit for the Primary RF Input Level Analog parameter. |
| FLO rsw1000bmaxValuePriRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.11 | Float | read-only | The value of this object represents a gauge maximum limit for the Primary RF Input Level Analog parameter. |
| INT rsw1000balarmStatePriRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Primary RF Input Level Analog parameter. |
| STR rsw1000blabelSecRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Secondary RF Input Level Analog parameter. |
| STR rsw1000buomSecRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Secondary RF Input Level Analog parameter. For all analog objects for this parameter type, the Unit of Measure is dBmV. |
| FLO rsw1000bmajorHighSecRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.15 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major High alarm value of the Secondary RF Input Level Analog parameter. |
| FLO rsw1000bmajorLowSecRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.16 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major Low alarm value of the Secondary RF Input Level Analog parameter. |
| FLO rsw1000bminorHighSecRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.17 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Secondary RF Input Level Analog parameter. |
| FLO rsw1000bminorLowSecRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.18 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Secondary RF Input Level Analog parameter. |
| FLO rsw1000bcurrentValueSecRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.19 | Float | read-only | The value of this object provides the current value of the Secondary RF Input Level Analog parameter. |
| INT rsw1000bstateFlagSecRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Secondary RF Input Level Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO rsw1000bminValueSecRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.21 | Float | read-only | The value of this object represents a gauge minimum limit for the Secondary RF Input Level Analog parameter. |
| FLO rsw1000bmaxValueSecRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.22 | Float | read-only | The value of this object represents a gauge maximum limit for the Secondary RF Input Level Analog parameter. |
| INT rsw1000balarmStateSecRFInputLvl | 1.3.6.1.4.1.1166.6.1.2.18.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Secondary RF Input Level Analog parameter. |
| STR rsw1000blabelPriRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Primary RF Threshold Analog parameter. |
| STR rsw1000buomPriRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Primary RF Threshold Analog parameter. For all analog objects for this parameter type, the Unit of Measure is dBmV. |
| FLO rsw1000bmajorHighPriRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.26 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major High alarm value of the Primary RF Threshold Analog parameter. |
| FLO rsw1000bmajorLowPriRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.27 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major Low alarm value of the Primary RF Threshold Analog parameter. |
| FLO rsw1000bminorHighPriRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.28 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Primary RF Threshold Analog parameter. |
| FLO rsw1000bminorLowPriRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.29 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Primary RF Threshold Analog parameter. |
| FLO rsw1000bcurrentValuePriRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.30 | Float | read-write | The value of this object provides the current value of the Primary RF Threshold Analog parameter. |
| INT rsw1000bstateFlagPriRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Primary RF Threshold Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO rsw1000bminValuePriRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.32 | Float | read-only | The value of this object represents a gauge minimum limit for the Primary RF Threshold Analog parameter. |
| FLO rsw1000bmaxValuePriRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.33 | Float | read-only | The value of this object represents a gauge maximum limit for the Primary RF Threshold Analog parameter. |
| INT rsw1000balarmStatePriRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Primary RF Threshold Analog parameter. |
| STR rsw1000blabelSecRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Secondary RF Threshold Analog parameter. |
| STR rsw1000buomSecRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Secondary RF Threshold Analog parameter. For all analog objects for this parameter type, the Unit of Measure is dBmV. |
| FLO rsw1000bmajorHighSecRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.37 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major High alarm value of the Secondary RF Threshold Analog parameter. |
| FLO rsw1000bmajorLowSecRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.38 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major Low alarm value of the Secondary RF Threshold Analog parameter. |
| FLO rsw1000bminorHighSecRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.39 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Secondary RF Threshold Analog parameter. |
| FLO rsw1000bminorLowSecRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.40 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Secondary RF Threshold Analog parameter. |
| FLO rsw1000bcurrentValueSecRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.41 | Float | read-write | The value of this object provides the current value of the Secondary RF Threshold Analog parameter. |
| INT rsw1000bstateFlagSecRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Secondary RF Threshold Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO rsw1000bminValueSecRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.43 | Float | read-only | The value of this object represents a gauge minimum limit for the Secondary RF Threshold Analog parameter. |
| FLO rsw1000bmaxValueSecRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.44 | Float | read-only | The value of this object represents a gauge maximum limit for the Secondary RF Threshold Analog parameter. |
| INT rsw1000balarmStateSecRFThreshold | 1.3.6.1.4.1.1166.6.1.2.18.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Secondary RF Threshold Analog parameter. |
| STR rsw1000blabelModTemp | 1.3.6.1.4.1.1166.6.1.2.18.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR rsw1000buomModTemp | 1.3.6.1.4.1.1166.6.1.2.18.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. For all analog objects for this parameter type, the Unit of Measure is degrees Celsius. |
| FLO rsw1000bmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.18.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. |
| FLO rsw1000bmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.18.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. |
| FLO rsw1000bminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.18.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. |
| FLO rsw1000bminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.18.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. |
| FLO rsw1000bcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.18.2.1.52 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. |
| INT rsw1000bstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.18.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO rsw1000bminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.18.2.1.54 | Float | read-only | The value of this object represents a gauge minimum limit for the Module Temperature Analog parameter. |
| FLO rsw1000bmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.18.2.1.55 | Float | read-only | The value of this object represents a gauge maximum limit for the Module Temperature Analog parameter. |
| INT rsw1000balarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.18.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR rsw1000blabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.18.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR rsw1000buomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.18.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. For all analog objects for this parameter type, the Unit of Measure is mA |
| FLO rsw1000bmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.18.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. |
| FLO rsw1000bmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.18.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. |
| FLO rsw1000bminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.18.2.1.61 | Float | read-only | This object is not used by this module and always returns invalid floating point value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. |
| FLO rsw1000bminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.18.2.1.62 | Float | read-only | This object is not used by this module and always returns invalid floating point value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. |
| FLO rsw1000bcurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.18.2.1.63 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. |
| INT rsw1000bstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.18.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO rsw1000bminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.18.2.1.65 | Float | read-only | The value of this object represents a gauge minimum limit for the Fan Current Analog parameter. |
| FLO rsw1000bmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.18.2.1.66 | Float | read-only | The value of this object represents a gauge maximum limit for the Fan Current Analog parameter. |
| INT rsw1000balarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.18.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| gx2Rsw1000bDigitalTable | 1.3.6.1.4.1.1166.6.1.2.18.3 | not-accessible | This table contains gx2Rsw1000b specific parameters with nominal and current values. | |
| gx2Rsw1000bDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.18.3.2 | not-accessible | This list contains digital parameters and descriptions. | |
| INT gx2Rsw1000bDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.18.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR rsw1000blabelSwitchControl | 1.3.6.1.4.1.1166.6.1.2.18.3.2.2 | DisplayString | read-only | The value of this object provides the label of the Switch Control Digital parameter. |
| STR rsw1000benumSwitchControl | 1.3.6.1.4.1.1166.6.1.2.18.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rsw1000bvalueSwitchControl | 1.3.6.1.4.1.1166.6.1.2.18.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rsw1000bstateflagSwitchControl | 1.3.6.1.4.1.1166.6.1.2.18.3.2.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR rsw1000blabelSwitchMode | 1.3.6.1.4.1.1166.6.1.2.18.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Revert Mode Digital parameter. |
| STR rsw1000benumSwitchMode | 1.3.6.1.4.1.1166.6.1.2.18.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rsw1000bvalueSwitchMode | 1.3.6.1.4.1.1166.6.1.2.18.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rsw1000bstateflagSwitchMode | 1.3.6.1.4.1.1166.6.1.2.18.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR rsw1000blabelRevertEnable | 1.3.6.1.4.1.1166.6.1.2.18.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Revert Enable Digital parameter. |
| STR rsw1000benumRevertEnable | 1.3.6.1.4.1.1166.6.1.2.18.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rsw1000bvalueRevertEnable | 1.3.6.1.4.1.1166.6.1.2.18.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rsw1000bstateflagRevertEnable | 1.3.6.1.4.1.1166.6.1.2.18.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| STR rsw1000blabelRevertTime | 1.3.6.1.4.1.1166.6.1.2.18.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Revert Time Digital parameter. |
| STR rsw1000benumRevertTime | 1.3.6.1.4.1.1166.6.1.2.18.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rsw1000bvalueRevertTime | 1.3.6.1.4.1.1166.6.1.2.18.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rsw1000bstateflagRevertTime | 1.3.6.1.4.1.1166.6.1.2.18.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable). |
| STR rsw1000blabelSensorMode | 1.3.6.1.4.1.1166.6.1.2.18.3.2.18 | DisplayString | read-only | The value of this object provides the label of the SensorMode Digital parameter. |
| STR rsw1000benumSensorMode | 1.3.6.1.4.1.1166.6.1.2.18.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rsw1000bvalueSensorMode | 1.3.6.1.4.1.1166.6.1.2.18.3.2.20 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rsw1000bstateflagSensorMode | 1.3.6.1.4.1.1166.6.1.2.18.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR rsw1000blabelSwitchMonitor | 1.3.6.1.4.1.1166.6.1.2.18.3.2.22 | DisplayString | read-only | The value of this object provides the label of the Switch Monitor Digital parameter. |
| STR rsw1000benumSwitchMonitor | 1.3.6.1.4.1.1166.6.1.2.18.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rsw1000bvalueSwitchMonitor | 1.3.6.1.4.1.1166.6.1.2.18.3.2.24 | INTEGER | read-only | The value of this object is the current value of the parameter. |
| INT rsw1000bstateflagSwitchMonitor | 1.3.6.1.4.1.1166.6.1.2.18.3.2.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR rsw1000blabelPriStatusSig | 1.3.6.1.4.1.1166.6.1.2.18.3.2.26 | DisplayString | read-only | The value of this object provides the label of the Primary Control Signal Digital parameter. |
| STR rsw1000benumPriStatusSig | 1.3.6.1.4.1.1166.6.1.2.18.3.2.27 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rsw1000bvaluePriStatusSig | 1.3.6.1.4.1.1166.6.1.2.18.3.2.28 | INTEGER | read-only | The value of this object is the current value of the parameter. |
| INT rsw1000bstateflagPriStatusSig | 1.3.6.1.4.1.1166.6.1.2.18.3.2.29 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR rsw1000blabelSecStatusSig | 1.3.6.1.4.1.1166.6.1.2.18.3.2.30 | DisplayString | read-only | The value of this object provides the label of the Secondary Control Signal Digital parameter. |
| STR rsw1000benumSecStatusSig | 1.3.6.1.4.1.1166.6.1.2.18.3.2.31 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rsw1000bvalueSecStatusSig | 1.3.6.1.4.1.1166.6.1.2.18.3.2.32 | INTEGER | read-only | The value of this object is the current value of the parameter. |
| INT rsw1000bstateflagSecStatusSig | 1.3.6.1.4.1.1166.6.1.2.18.3.2.33 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR rsw1000blabelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.18.3.2.34 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR rsw1000benumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.18.3.2.35 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rsw1000bvalueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.18.3.2.36 | INTEGER | read-write | This is a one-shot control value. A read of this value is always the value corresponding to off(1). A write of the value corresponding to on(2) results in effecting the factory default reset. A write of the value corresponding to off(1) has no effect. |
| INT rsw1000bstateflagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.18.3.2.37 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| gx2Rsw1000bStatusTable | 1.3.6.1.4.1.1166.6.1.2.18.4 | not-accessible | This table contains gx2Rsw1000b specific parameters with nominal and current values. | |
| gx2Rsw1000bStatusEntry | 1.3.6.1.4.1.1166.6.1.2.18.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2Rsw1000bStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.18.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR rsw1000blabelBoot | 1.3.6.1.4.1.1166.6.1.2.18.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT rsw1000bvalueBoot | 1.3.6.1.4.1.1166.6.1.2.18.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT rsw1000bstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.18.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR rsw1000blabelFlash | 1.3.6.1.4.1.1166.6.1.2.18.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT rsw1000bvalueFlash | 1.3.6.1.4.1.1166.6.1.2.18.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT rsw1000bstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.18.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR rsw1000blabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.18.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT rsw1000bvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.18.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT rsw1000bstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.18.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR rsw1000blabelRFDataCRC | 1.3.6.1.4.1.1166.6.1.2.18.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Radio Frequency Data CRC Status parameter. |
| INT rsw1000bvalueRFDataCRC | 1.3.6.1.4.1.1166.6.1.2.18.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT rsw1000bstateflagRFDataCRC | 1.3.6.1.4.1.1166.6.1.2.18.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR rsw1000blabelAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.18.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT rsw1000bvalueAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.18.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT rsw1000bstateflagAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.18.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR rsw1000blabelRFSignalStatus | 1.3.6.1.4.1.1166.6.1.2.18.4.3.17 | DisplayString | read-only | The value of this object provides the label of the RF Signal Status parameter. |
| INT rsw1000bvalueRFSignalStatus | 1.3.6.1.4.1.1166.6.1.2.18.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT rsw1000bstateflagRFSignalStatus | 1.3.6.1.4.1.1166.6.1.2.18.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR rsw1000blabelPriActiveStatus | 1.3.6.1.4.1.1166.6.1.2.18.4.3.20 | DisplayString | read-only | The value of this object provides the label of the Secondary Active Status parameter. |
| INT rsw1000bvaluePriActiveStatus | 1.3.6.1.4.1.1166.6.1.2.18.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT rsw1000bstateflagPriActiveStatus | 1.3.6.1.4.1.1166.6.1.2.18.4.3.22 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| gx2Rsw1000bFactoryTable | 1.3.6.1.4.1.1166.6.1.2.18.5 | not-accessible | This table contains gx2Rsw1000b specific parameters with nominal and current values. | |
| gx2Rsw1000bFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.18.5.4 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2Rsw1000bFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.18.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT rsw1000bbootControlByte | 1.3.6.1.4.1.1166.6.1.2.18.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT rsw1000bbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.18.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT rsw1000bbank0CRC | 1.3.6.1.4.1.1166.6.1.2.18.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT rsw1000bbank1CRC | 1.3.6.1.4.1.1166.6.1.2.18.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT rsw1000bprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.18.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT rsw1000bfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.18.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT rsw1000bcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.18.5.4.8 | INTEGER | read-only | This oject indicates which of the Emnums will have the CRC calculated. |
| INT rsw1000bhourMeter | 1.3.6.1.4.1.1166.6.1.2.18.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT rsw1000bflashPrgCnt0 | 1.3.6.1.4.1.1166.6.1.2.18.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT rsw1000bflashPrgCnt1 | 1.3.6.1.4.1.1166.6.1.2.18.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR rsw1000bflashBank0Rev | 1.3.6.1.4.1.1166.6.1.2.18.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR rsw1000bflashBank1Rev | 1.3.6.1.4.1.1166.6.1.2.18.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
| STR rsw1000bSubagentRev | 1.3.6.1.4.1.1166.6.1.2.18.5.4.14 | DisplayString | read-only | This object provides the revision of the subagent. |
| gx2Rsw1000bHoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.18.6 | not-accessible | This table contains gx2Rsw1000b specific parameters with nominal and current values. | |
| gx2Rsw1000bHoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.18.6.5 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT rxgx2Rsw1000bHoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.18.6.5.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| INT rxgx2Rsw1000bHoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.18.6.5.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| INT rxgx2Rsw1000bHoldTimeData | 1.3.6.1.4.1.1166.6.1.2.18.6.5.3 | INTEGER | read-write | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds. |
RFC description
Manages RF (radio frequency) switch module monitoring and alarm reporting.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 RSW1000B 1000 MHz RF switch module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.