OMNI-gx2drt4x-MIB :: drt4xalarmStateLaserPowerMonitor

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2drt4x-MIB › drt4xalarmStateLaserPowerMonitor

drt4xalarmStateLaserPowerMonitor

Module: OMNI-gx2drt4x-MIB

OID (symbolic): OMNI-gx2drt4x-MIB::drt4xalarmStateLaserPowerMonitor

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.25.2.1.56

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The value of this object provides the curent alarm state of the trip point level Analog parameter.

What is drt4xalarmStateLaserPowerMonitor?

This is the current alarm severity for optical input trip point: noAlarm, majorLowAlarm, minorLowAlarm, minorHighAlarm, majorHighAlarm, or informational. A monitoring system reads this directly instead of re-evaluating the raw value against the threshold objects, since the module has already done that comparison internally. An admin scanning for problems can poll just this one object per parameter to know whether it currently needs attention.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.25.2.1.56
snmpwalk -v2c -c public <target> OMNI-gx2drt4x-MIB::drt4xalarmStateLaserPowerMonitor

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.25.2.1.56.1
snmpget -v2c -c public <target> OMNI-gx2drt4x-MIB::drt4xalarmStateLaserPowerMonitor.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRT4X downstream RF transmitter card) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2drt4x-MIB::drt4xalarmStateLaserPowerMonitor OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRT4X downstream RF transmitter card) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.25gx2Drt4xGX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.25.2gx2drt4xAnalogTableOMNI-gx2drt4x-MIB
1.3.6.1.4.1.1166.6.1.2.25.2.1gx2drt4xAnalogEntryOMNI-gx2drt4x-MIB
1.3.6.1.4.1.1166.6.1.2.25.2.1.56drt4xalarmStateLaserPowerMonitorOMNI-gx2drt4x-MIB