All MIBs › OMNI-gx2dualdrr2x-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 Dual DRR2X dual-port downstream RF receiver card in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2dualdrr2x-MIB?
OMNI-gx2dualdrr2x-MIB is a legacy proprietary MIB (built on GX2HFC-MIB/NLSBBN-TRAPS-MIB) reporting analog/digital telemetry for the gx2dualdrr2x HFC (Hybrid Fiber-Coax) module — a dual optical receiver. Its analog table records per-parameter (e.g., received optical power 1/2) label, unit of measure, major/minor high/low thresholds, current value, state flag, min/max recorded value, and alarm state, with companion digital-status and factory tables. As a status/performance MIB it lets an administrator watch received optical power against alarm thresholds on this legacy HFC dual-receiver module. It is deployed on legacy HFC (Hybrid Fiber-Coax) dual optical-receiver equipment. Engineers can download the OMNI-gx2dualdrr2x-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2dualdrr2x-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (gx2dualdrr2x dual optical receiver module)
Monitoring Examples
An administrator checks dualdrr2xcurrentValueRecdOptPwr1 against dualdrr2xminorLowRecdOptPwr1 to catch a degrading optical receiver on this legacy HFC module.
What Can Be Monitored
- received optical power against alarm thresholds
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2DualDrr2x | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapdualdrrConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.35.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapdualdrrConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.35.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapdualdrr12VCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.3 | This trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapdualdrrModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.4 | This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapdualdrrFanSpeedAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.5 | This trap is issued when the Fan Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapdualdrrFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.6 | This trap is issued when the detects an error during Flash memory operations. | ||
| NTF trapdualdrrBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.7 | This trap is issued when the module detects an error while booting from bank 0 or bank 1. | ||
| NTF trapdualdrrAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.8 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapdualdrrHardwareErrAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.9 | This trap is issued when hardware is abnormal. | ||
| NTF trapdualdrrOpticalSignal1Alarm | 1.3.6.1.4.1.1166.6.1.2.35.0.10 | This trap is issued when the optical signal 1 is beyond the preset range. | ||
| NTF trapdualdrrOpticalSignal2Alarm | 1.3.6.1.4.1.1166.6.1.2.35.0.11 | This trap is issued when the optical signal 2 is beyond the preset range. | ||
| NTF trapdualdrrFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.12 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapdualdrrResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.13 | This trap is issued when the Factory Default Reset occurs. | ||
| NTF trapdualdrrTripPoint1Alarm | 1.3.6.1.4.1.1166.6.1.2.35.0.14 | This trap is issued when the Input 1 optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM. | ||
| NTF trapdualdrrTripPoint2Alarm | 1.3.6.1.4.1.1166.6.1.2.35.0.15 | This trap is issued when the Input 2 optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM. | ||
| NTF trapdualdrrLink1Alarm | 1.3.6.1.4.1.1166.6.1.2.35.0.16 | This trap is issued when receiver 1 is out of SYN with transmitter | ||
| NTF trapdualdrrLink2Alarm | 1.3.6.1.4.1.1166.6.1.2.35.0.17 | This trap is issued when receiver 2 is out of SYN with transmitter | ||
| NTF trapdualdrrCalibrationDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.18 | This trap is issued when the Calibration Data CRC is incorrect | ||
| NTF trapdualdrrSFP1OptPWRAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.19 | This trap is issued when SFP 1's optical power is incorrect | ||
| NTF trapdualdrrDRT1Cur24VAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.20 | This trap is issued when DRT 1's 24 volt current is incorrect | ||
| NTF trapdualdrrDRT1ModTempAarm | 1.3.6.1.4.1.1166.6.1.2.35.0.21 | This trap is issued when DRT 1's Module telperature is incorrect | ||
| NTF trapdualdrrSFP2OptPWRAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.22 | This trap is issued when SFP 2's optical power is incorrect | ||
| NTF trapdualdrrDRT2Cur24VAlarm | 1.3.6.1.4.1.1166.6.1.2.35.0.23 | This trap is issued when DRT 2's 24 volt current is incorrect | ||
| NTF trapdualdrrDRT2ModTempAarm | 1.3.6.1.4.1.1166.6.1.2.35.0.24 | This trap is issued when DRT 2's Module telperature is incorrect | ||
| gx2dualdrr2xDescriptor | 1.3.6.1.4.1.1166.6.1.2.35.1 | |||
| gx2dualdrr2xAnalogTable | 1.3.6.1.4.1.1166.6.1.2.35.2 | not-accessible | This table contains gx2dualdrr2x specific analog parameters with nominal,limits and current values. | |
| gx2dualdrr2xAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.35.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2dualdrr2xAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.35.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR dualdrr2xlabelRecdOptPwr1 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Channel 1 Received Opt power Analog parameter. |
| STR dualdrr2xuomRecdOptPwr1 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Channel 1 Received Opt power Analog parameter. |
| FLO dualdrr2xmajorHighRecdOptPwr1 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.4 | Float | read-only | This object is not used by this module and always returns the value of the Channel 1 Received Opt power Major High Alarm Limit Analog parameter. |
| FLO dualdrr2xmajorLowRecdOptPwr1 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.5 | Float | read-only | This object is not used by this module and always returns the value of the Channel 1 Received Opt power Major High Alarm Limit Analog parameter. |
| FLO dualdrr2xminorHighRecdOptPwr1 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.6 | Float | read-only | This object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence. |
| FLO dualdrr2xminorLowRecdOptPwr1 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.7 | Float | read-only | This object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueRecdOptPwr1 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.8 | Float | read-write | The value of this object provides the Current value of the Channel 1 Received Opt power. |
| INT dualdrr2xstateFlagRecdOptPwr1 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Channel 1 Received Opt power Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueRecdOptPwr1 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.10 | Float | read-only | The value of this object provides the minimum value of the Channel 1 Received Opt power. |
| FLO dualdrr2xmaxValueRecdOptPwr1 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.11 | Float | read-only | The value of this object provides the maximum value of the Channel 1 Received Opt power. |
| INT dualdrr2xalarmStateRecdOptPwr1 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Channel 1 Received Opt power. |
| STR dualdrr2xlabelRecdOptPwr2 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Channel 2 Received Opt power Analog parameter. |
| STR dualdrr2xuomRecdOptPwr2 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Channel 2 Received Opt power Analog parameter. |
| FLO dualdrr2xmajorHighRecdOptPwr2 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.15 | Float | read-only | This object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter. |
| FLO dualdrr2xmajorLowRecdOptPwr2 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.16 | Float | read-only | This object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter. |
| FLO dualdrr2xminorHighRecdOptPwr2 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.17 | Float | read-only | This object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence. |
| FLO dualdrr2xminorLowRecdOptPwr2 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.18 | Float | read-only | This object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueRecdOptPwr2 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.19 | Float | read-write | The value of this object provides the Current value of the Channel 2 Received Opt power. |
| INT dualdrr2xstateFlagRecdOptPwr2 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Channel 2 Received Opt power Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueRecdOptPwr2 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.21 | Float | read-only | The value of this object provides the minimum value of the Channel 2 Received Opt power. |
| FLO dualdrr2xmaxValueRecdOptPwr2 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.22 | Float | read-only | The value of this object provides the maximum value of the Channel 2 Received Opt power. |
| INT dualdrr2xalarmStateRecdOptPwr2 | 1.3.6.1.4.1.1166.6.1.2.35.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Channel 2 Received optical power. |
| STR dualdrr2xlabelModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR dualdrr2xuomModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO dualdrr2xmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. |
| FLO dualdrr2xmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. |
| FLO dualdrr2xminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. |
| FLO dualdrr2xminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. |
| FLO dualdrr2xcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.30 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. |
| INT dualdrr2xstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.32 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. |
| FLO dualdrr2xmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.33 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. |
| INT dualdrr2xalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR dualdrr2xlabel12VCurrent | 1.3.6.1.4.1.1166.6.1.2.35.2.1.35 | DisplayString | read-only | The value of this object provides the label of the 12v power supply Current Analog parameter. |
| STR dualdrr2xuom12VCurrent | 1.3.6.1.4.1.1166.6.1.2.35.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter. |
| FLO dualdrr2xmajorHigh12VCurrent | 1.3.6.1.4.1.1166.6.1.2.35.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter. |
| FLO dualdrr2xmajorLow12VCurrent | 1.3.6.1.4.1.1166.6.1.2.35.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter. |
| FLO dualdrr2xminorHigh12VCurrent | 1.3.6.1.4.1.1166.6.1.2.35.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter. |
| FLO dualdrr2xminorLow12VCurrent | 1.3.6.1.4.1.1166.6.1.2.35.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter. |
| FLO dualdrr2xcurrentValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.35.2.1.41 | Float | read-only | The value of this object provides the Current value of the 12v power supply Current parameter. |
| INT dualdrr2xstateFlag12VCurrent | 1.3.6.1.4.1.1166.6.1.2.35.2.1.42 | INTEGER | read-only | The value of this object provides the state of the 12v power supply Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.35.2.1.43 | Float | read-only | The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive. |
| FLO dualdrr2xmaxValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.35.2.1.44 | Float | read-only | The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive. |
| INT dualdrr2xalarmState12VCurrent | 1.3.6.1.4.1.1166.6.1.2.35.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter. |
| STR dualdrr2xlabelFanSpeed | 1.3.6.1.4.1.1166.6.1.2.35.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Fan Speed Analog parameter. |
| STR dualdrr2xuomFanSpeed | 1.3.6.1.4.1.1166.6.1.2.35.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Speed Analog parameter. |
| FLO dualdrr2xmajorHighFanSpeed | 1.3.6.1.4.1.1166.6.1.2.35.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Speed Analog parameter. |
| FLO dualdrr2xmajorLowFanSpeed | 1.3.6.1.4.1.1166.6.1.2.35.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Speed Analog parameter. |
| FLO dualdrr2xminorHighFanSpeed | 1.3.6.1.4.1.1166.6.1.2.35.2.1.50 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xminorLowFanSpeed | 1.3.6.1.4.1.1166.6.1.2.35.2.1.51 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueFanSpeed | 1.3.6.1.4.1.1166.6.1.2.35.2.1.52 | Float | read-only | The value of this object provides the current value of the Fan Speed Analog parameter. |
| INT dualdrr2xstateFlagFanSpeed | 1.3.6.1.4.1.1166.6.1.2.35.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Fan Speed Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueFanSpeed | 1.3.6.1.4.1.1166.6.1.2.35.2.1.54 | Float | read-only | The value of this object provides the minimum value the Fan Speed Analog parameter can achive. |
| FLO dualdrr2xmaxValueFanSpeed | 1.3.6.1.4.1.1166.6.1.2.35.2.1.55 | Float | read-only | The value of this object provides the maximum value the Fan Speed Analog parameter can achive. |
| INT dualdrr2xalarmStateFanSpeed | 1.3.6.1.4.1.1166.6.1.2.35.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Speed Analog parameter. |
| STR dualdrr2xlabelTx0SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Tx 0 SFP Wavelength Analog parameter. |
| STR dualdrr2xuomTx0SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Tx 0 SFP Wavelength Analog parameter. |
| FLO dualdrr2xmajorHighTx0SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Tx 0 SFP Wavelength Analog parameter. |
| FLO dualdrr2xmajorLowTx0SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Tx 0 SFP Wavelength Analog parameter. |
| FLO dualdrr2xminorHighTx0SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.61 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xminorLowTx0SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.62 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueTx0SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.63 | Float | read-only | The value of this object provides the current value of the Tx 0 SFP Wavelength Analog parameter. |
| INT dualdrr2xstateFlagTx0SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Tx 0 SFP Wavelength Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueTx0SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.65 | Float | read-only | The value of this object provides the minimum value the Tx 0 SFP Wavelength Analog parameter can achive. |
| FLO dualdrr2xmaxValueTx0SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.66 | Float | read-only | The value of this object provides the maximum value the Tx 0 SFP Wavelength Analog parameter can achive. |
| INT dualdrr2xalarmStateTx0SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Tx 0 SFP Wavelength Analog parameter. |
| STR dualdrr2xlabelTx0OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Tx 0 Optical Power Analog parameter. |
| STR dualdrr2xuomTx0OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Tx 0 Optical Power Analog parameter. |
| FLO dualdrr2xmajorHighTx0OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Tx 0 Optical Power Analog parameter. |
| FLO dualdrr2xmajorLowTx0OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Tx 0 Optical Power Analog parameter. |
| FLO dualdrr2xminorHighTx0OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.72 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xminorLowTx0OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.73 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueTx0OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.74 | Float | read-only | The value of this object provides the current value of the Tx 0 Optical Power Analog parameter. |
| INT dualdrr2xstateFlagTx0OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Tx 0 Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueTx0OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.76 | Float | read-only | The value of this object provides the minimum value the Tx 0 Optical Power Analog parameter can achive. |
| FLO dualdrr2xmaxValueTx0OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.77 | Float | read-only | The value of this object provides the maximum value the Tx 0 Optical Power Analog parameter can achive. |
| INT dualdrr2xalarmStateTx0OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Tx 0 Optical Power Analog parameter. |
| STR dualdrr2xlabelTx024vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.79 | DisplayString | read-only | The value of this object provides the label of the Tx 0 24 Volt Current Analog parameter. |
| STR dualdrr2xuomTx024vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Tx 0 24 Volt Current Analog parameter. |
| FLO dualdrr2xmajorHighTx024vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the Tx 0 24 Volt Current Analog parameter. |
| FLO dualdrr2xmajorLowTx024vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the Tx 0 24 Volt Current Analog parameter. |
| FLO dualdrr2xminorHighTx024vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.83 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xminorLowTx024vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.84 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueTx024vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.85 | Float | read-only | The value of this object provides the current value of the Tx 0 24 Volt Current Analog parameter. |
| INT dualdrr2xstateFlagTx024vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.86 | INTEGER | read-only | The value of this object provides the state of the Tx 0 24 Volt Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueTx024vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.87 | Float | read-only | The value of this object provides the minimum value the Tx 0 24 Volt Current Analog parameter can achive. |
| FLO dualdrr2xmaxValueTx024vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.88 | Float | read-only | The value of this object provides the maximum value the Tx 0 24 Volt Current Analog parameter can achive. |
| INT dualdrr2xalarmStateTx024vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the Tx 0 24 Volt Current Analog parameter. |
| STR dualdrr2xlabelTx024Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.90 | DisplayString | read-only | The value of this object provides the label of the Tx 0 24 Volt supply voltage Analog parameter. |
| STR dualdrr2xuomTx024Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.91 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Tx 0 24 Volt supply voltage Analog parameter. |
| FLO dualdrr2xmajorHighTx024Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.92 | Float | read-only | The value of this object provides the Major High alarm value of the Tx 0 24 Volt supply voltage Analog parameter. |
| FLO dualdrr2xmajorLowTx024Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.93 | Float | read-only | The value of this object provides the Major Low alarm value of the Tx 0 24 Volt supply voltage Analog parameter. |
| FLO dualdrr2xminorHighTx024Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.94 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xminorLowTx024Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.95 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueTx024Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.96 | Float | read-only | The value of this object provides the current value of the Tx 0 24 Volt supply voltage Analog parameter. |
| INT dualdrr2xstateFlagTx024Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.97 | INTEGER | read-only | The value of this object provides the state of the Tx 0 24 Volt supply voltage Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueTx024Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.98 | Float | read-only | The value of this object provides the minimum value the Tx 0 24 Volt supply voltage Analog parameter can achive. |
| FLO dualdrr2xmaxValueTx024Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.99 | Float | read-only | The value of this object provides the maximum value the Tx 0 24 Volt supply voltage Analog parameter can achive. |
| INT dualdrr2xalarmStateTx024Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.100 | INTEGER | read-only | The value of this object provides the curent alarm state of the Tx 0 24 Volt supply voltage Analog parameter. |
| STR dualdrr2xlabelTx0ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.101 | DisplayString | read-only | The value of this object provides the label of the Tx 0 24 Module Temperature Analog parameter. |
| STR dualdrr2xuomTx0ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.102 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Tx 0 Module Temperature Analog parameter. |
| FLO dualdrr2xmajorHighTx0ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.103 | Float | read-only | The value of this object provides the Major High alarm value of the Tx 0 Module Temperature Analog parameter. |
| FLO dualdrr2xmajorLowTx0ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.104 | Float | read-only | The value of this object provides the Major Low alarm value of the Tx 0 Module Temperature Analog parameter. |
| FLO dualdrr2xminorHighTx0ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.105 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xminorLowTx0ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.106 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueTx0ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.107 | Float | read-only | The value of this object provides the current value of the Tx 0 Module Temperature Analog parameter. |
| INT dualdrr2xstateFlagTx0ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.108 | INTEGER | read-only | The value of this object provides the state of the Tx 0 Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueTx0ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.109 | Float | read-only | The value of this object provides the minimum value the Tx 0 Module Temperature Analog parameter can achive. |
| FLO dualdrr2xmaxValueTx0ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.110 | Float | read-only | The value of this object provides the maximum value the Tx 0 Module Temperature Analog parameter can achive. |
| INT dualdrr2xalarmStateTx0ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.111 | INTEGER | read-only | The value of this object provides the curent alarm state of the Tx 0 Module Temperature Analog parameter. |
| STR dualdrr2xlabelTx1SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.112 | DisplayString | read-only | The value of this object provides the label of the Tx 1 SFP Wavelength Analog parameter. |
| STR dualdrr2xuomTx1SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.113 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Tx 1 SFP Wavelength Analog parameter. |
| FLO dualdrr2xmajorHighTx1SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.114 | Float | read-only | The value of this object provides the Major High alarm value of the Tx 1 SFP Wavelength Analog parameter. |
| FLO dualdrr2xmajorLowTx1SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.115 | Float | read-only | The value of this object provides the Major Low alarm value of the Tx 1 SFP Wavelength Analog parameter. |
| FLO dualdrr2xminorHighTx1SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.116 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xminorLowTx1SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.117 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueTx1SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.118 | Float | read-only | The value of this object provides the current value of the Tx 1 SFP Wavelength Analog parameter. |
| INT dualdrr2xstateFlagTx1SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.119 | INTEGER | read-only | The value of this object provides the state of the Tx 1 SFP Wavelength Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueTx1SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.120 | Float | read-only | The value of this object provides the minimum value the Tx 1 SFP Wavelength Analog parameter can achive. |
| FLO dualdrr2xmaxValueTx1SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.121 | Float | read-only | The value of this object provides the maximum value the Tx 1 SFP Wavelength Analog parameter can achive. |
| INT dualdrr2xalarmStateTx1SFPWave | 1.3.6.1.4.1.1166.6.1.2.35.2.1.122 | INTEGER | read-only | The value of this object provides the curent alarm state of the Tx 1 SFP Wavelength Analog parameter. |
| STR dualdrr2xlabelTx1OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.123 | DisplayString | read-only | The value of this object provides the label of the Tx 1 Optical Power Analog parameter. |
| STR dualdrr2xuomTx1OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.124 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Tx 1 Optical Power Analog parameter. |
| FLO dualdrr2xmajorHighTx1OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.125 | Float | read-only | The value of this object provides the Major High alarm value of the Tx 1 Optical Power Analog parameter. |
| FLO dualdrr2xmajorLowTx1OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.126 | Float | read-only | The value of this object provides the Major Low alarm value of the Tx 1 Optical Power Analog parameter. |
| FLO dualdrr2xminorHighTx1OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.127 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xminorLowTx1OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.128 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueTx1OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.129 | Float | read-only | The value of this object provides the current value of the Tx 1 Optical Power Analog parameter. |
| INT dualdrr2xstateFlagTx1OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.130 | INTEGER | read-only | The value of this object provides the state of the Tx 1 Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueTx1OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.131 | Float | read-only | The value of this object provides the minimum value the Tx 1 Optical Power Analog parameter can achive. |
| FLO dualdrr2xmaxValueTx1OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.132 | Float | read-only | The value of this object provides the maximum value the Tx 1 Optical Power Analog parameter can achive. |
| INT dualdrr2xalarmStateTx1OptPwr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.133 | INTEGER | read-only | The value of this object provides the curent alarm state of the Tx 1 Optical Power Analog parameter. |
| STR dualdrr2xlabelTx124vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.134 | DisplayString | read-only | The value of this object provides the label of the Tx 1 24 VoltCurrent Analog parameter. |
| STR dualdrr2xuomTx124vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.135 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Tx 1 24 Volt Current Analog parameter. |
| FLO dualdrr2xmajorHighTx124vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.136 | Float | read-only | The value of this object provides the Major High alarm value of the Tx 1 24 Volt Current Analog parameter. |
| FLO dualdrr2xmajorLowTx124vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.137 | Float | read-only | The value of this object provides the Major Low alarm value of the Tx 1 24 Volt Current Analog parameter. |
| FLO dualdrr2xminorHighTx124vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.138 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xminorLowTx124vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.139 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueTx124vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.140 | Float | read-only | The value of this object provides the current value of the Tx 1 24 Volt Current Analog parameter. |
| INT dualdrr2xstateFlagTx124vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.141 | INTEGER | read-only | The value of this object provides the state of the Tx 1 24 Volt Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueTx124vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.142 | Float | read-only | The value of this object provides the minimum value the Tx 1 24 Volt Current Analog parameter can achive. |
| FLO dualdrr2xmaxValueTx124vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.143 | Float | read-only | The value of this object provides the maximum value the Tx 1 24 Volt Current Analog parameter can achive. |
| INT dualdrr2xalarmStateTx124vCurr | 1.3.6.1.4.1.1166.6.1.2.35.2.1.144 | INTEGER | read-only | The value of this object provides the curent alarm state of the Tx 1 24 Volt Current Analog parameter. |
| STR dualdrr2xlabelTx124Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.145 | DisplayString | read-only | The value of this object provides the label of the Tx 1 24 Volt supply voltage Analog parameter. |
| STR dualdrr2xuomTx124Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.146 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Tx 1 24 Volt supply voltage Analog parameter. |
| FLO dualdrr2xmajorHighTx124Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.147 | Float | read-only | The value of this object provides the Major High alarm value of the Tx 1 24 Volt supply voltage Analog parameter. |
| FLO dualdrr2xmajorLowTx124Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.148 | Float | read-only | The value of this object provides the Major Low alarm value of the Tx 1 24 Volt supply voltage Analog parameter. |
| FLO dualdrr2xminorHighTx124Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.149 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xminorLowTx124Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.150 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueTx124Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.151 | Float | read-only | The value of this object provides the current value of the Tx 1 24 Volt supply voltage Analog parameter. |
| INT dualdrr2xstateFlagTx124Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.152 | INTEGER | read-only | The value of this object provides the state of the Tx 1 24 Volt supply voltage Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueTx124Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.153 | Float | read-only | The value of this object provides the minimum value the Tx 1 24 Volt supply voltage Analog parameter can achive. |
| FLO dualdrr2xmaxValueTx124Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.154 | Float | read-only | The value of this object provides the maximum value the Tx 1 24 Volt supply voltage Analog parameter can achive. |
| INT dualdrr2xalarmStateTx124Volt | 1.3.6.1.4.1.1166.6.1.2.35.2.1.155 | INTEGER | read-only | The value of this object provides the curent alarm state of the Tx 1 24 Volt supply voltage Analog parameter. |
| STR dualdrr2xlabelTx1ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.156 | DisplayString | read-only | The value of this object provides the label of the Tx 1 24 Module Temperature Analog parameter. |
| STR dualdrr2xuomTx1ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.157 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Tx 1 Module Temperature Analog parameter. |
| FLO dualdrr2xmajorHighTx1ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.158 | Float | read-only | The value of this object provides the Major High alarm value of the Tx 1 Module Temperature Analog parameter. |
| FLO dualdrr2xmajorLowTx1ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.159 | Float | read-only | The value of this object provides the Major Low alarm value of the Tx 1 Module Temperature Analog parameter. |
| FLO dualdrr2xminorHighTx1ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.160 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xminorLowTx1ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.161 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO dualdrr2xcurrentValueTx1ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.162 | Float | read-only | The value of this object provides the current value of the Tx 1 Module Temperature Analog parameter. |
| INT dualdrr2xstateFlagTx1ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.163 | INTEGER | read-only | The value of this object provides the state of the Tx 1 Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dualdrr2xminValueTx1ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.164 | Float | read-only | The value of this object provides the minimum value the Tx 1 Module Temperature Analog parameter can achive. |
| FLO dualdrr2xmaxValueTx1ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.165 | Float | read-only | The value of this object provides the maximum value the Tx 1 Module Temperature Analog parameter can achive. |
| INT dualdrr2xalarmStateTx1ModTemp | 1.3.6.1.4.1.1166.6.1.2.35.2.1.166 | INTEGER | read-only | The value of this object provides the curent alarm state of the Tx 1 Module Temperature Analog parameter. |
| gx2dualdrr2xDigitalTable | 1.3.6.1.4.1.1166.6.1.2.35.3 | not-accessible | This table contains gx2dualdrr2x specific digital parameters with nominal and current values. | |
| gx2dualdrr2xDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.35.3.2 | not-accessible | This list contains individual digital parameters and descriptions. | |
| INT gx2dualdrr2xDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.35.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR dualdrr2xlabelTrippoint1Value | 1.3.6.1.4.1.1166.6.1.2.35.3.2.2 | DisplayString | read-only | The value of this object provides the label of the Trip point Value Digital parameter. The trip point Value defines the RF switch point based on the optical power input to the DRR |
| STR dualdrr2xenumTrippoint1Value | 1.3.6.1.4.1.1166.6.1.2.35.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT dualdrr2xvalueTrippoint1Value | 1.3.6.1.4.1.1166.6.1.2.35.3.2.4 | INTEGER | read-write | The value of this object reflects the setting of the threshold at which the Trip point activates. It is in 1 dB increments ranging from -25 to -5 dB. The user can enter a number from 0 to 20, where 0 = -5db and 19 = -25db |
| INT dualdrr2xstateflagTrippoint1Value | 1.3.6.1.4.1.1166.6.1.2.35.3.2.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelTrippoint1Mode | 1.3.6.1.4.1.1166.6.1.2.35.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical power input to the DRR |
| STR dualdrr2xenumTrippoint1Mode | 1.3.6.1.4.1.1166.6.1.2.35.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT dualdrr2xvalueTrippoint1Mode | 1.3.6.1.4.1.1166.6.1.2.35.3.2.8 | INTEGER | read-write | The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical power is higher than the preset trippoint value, no operational difference for these three modes. If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml |
| INT dualdrr2xstateflagTrippoint1Mode | 1.3.6.1.4.1.1166.6.1.2.35.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelTrippoint2Value | 1.3.6.1.4.1.1166.6.1.2.35.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Trip point Value Digital parameter. The trip point Value defines the RF switch point based on the optical power input to the DRR |
| STR dualdrr2xenumTrippoint2Value | 1.3.6.1.4.1.1166.6.1.2.35.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT dualdrr2xvalueTrippoint2Value | 1.3.6.1.4.1.1166.6.1.2.35.3.2.12 | INTEGER | read-write | The value of this object reflects the setting of the threshold at which the Trip point activates. It is in 1 dB increments ranging from -25 to -5 dB. The user can enter a number from 0 to 20, where 0 = -5db and 19 = -25db |
| INT dualdrr2xstateflagTrippoint2Value | 1.3.6.1.4.1.1166.6.1.2.35.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelTrippoint2Mode | 1.3.6.1.4.1.1166.6.1.2.35.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical power input to the DRR |
| STR dualdrr2xenumTrippoint2Mode | 1.3.6.1.4.1.1166.6.1.2.35.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT dualdrr2xvalueTrippoint2Mode | 1.3.6.1.4.1.1166.6.1.2.35.3.2.16 | INTEGER | read-write | The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical power is higher than the preset trippoint value, no operational difference for these three modes. If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml |
| INT dualdrr2xstateflagTrippoint2Mode | 1.3.6.1.4.1.1166.6.1.2.35.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelGainChannel1A | 1.3.6.1.4.1.1166.6.1.2.35.3.2.18 | DisplayString | read-only | The value of this object provides the label of the RF Channel 1A Gain Digital parameter. |
| STR dualdrr2xenumGainChannel1A | 1.3.6.1.4.1.1166.6.1.2.35.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT dualdrr2xvalueGainChannel1A | 1.3.6.1.4.1.1166.6.1.2.35.3.2.20 | INTEGER | read-write | The value of this object reflects the setting of the gain for RF Channel 1A. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from 0 to 20 |
| INT dualdrr2xstateflagGainChannel1A | 1.3.6.1.4.1.1166.6.1.2.35.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelGainChannel1B | 1.3.6.1.4.1.1166.6.1.2.35.3.2.22 | DisplayString | read-only | The value of this object provides the label of the RF Channel 1B Gain Digital parameter. |
| STR dualdrr2xenumGainChannel1B | 1.3.6.1.4.1.1166.6.1.2.35.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT dualdrr2xvalueGainChannel1B | 1.3.6.1.4.1.1166.6.1.2.35.3.2.24 | INTEGER | read-write | The value of this object reflects the setting of the gain for RF Channel 1B. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from 0 to 20 |
| INT dualdrr2xstateflagGainChannel1B | 1.3.6.1.4.1.1166.6.1.2.35.3.2.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelGainChannel2A | 1.3.6.1.4.1.1166.6.1.2.35.3.2.26 | DisplayString | read-only | The value of this object provides the label of the RF Channel 2A Gain Digital parameter. |
| STR dualdrr2xenumGainChannel2A | 1.3.6.1.4.1.1166.6.1.2.35.3.2.27 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT dualdrr2xvalueGainChannel2A | 1.3.6.1.4.1.1166.6.1.2.35.3.2.28 | INTEGER | read-write | The value of this object reflects the setting of the gain for RF Channel 2A. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from 0 to 20 |
| INT dualdrr2xstateflagGainChannel2A | 1.3.6.1.4.1.1166.6.1.2.35.3.2.29 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelGainChannel2B | 1.3.6.1.4.1.1166.6.1.2.35.3.2.30 | DisplayString | read-only | The value of this object provides the label of the RF Channel 2B Gain Digital parameter. |
| STR dualdrr2xenumGainChannel2B | 1.3.6.1.4.1.1166.6.1.2.35.3.2.31 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT dualdrr2xvalueGainChannel2B | 1.3.6.1.4.1.1166.6.1.2.35.3.2.32 | INTEGER | read-write | The value of this object reflects the setting of the gain for RF Channel 2B. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from 0 to 20 |
| INT dualdrr2xstateflagGainChannel2B | 1.3.6.1.4.1.1166.6.1.2.35.3.2.33 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelTestpointSelect | 1.3.6.1.4.1.1166.6.1.2.35.3.2.34 | DisplayString | read-only | The value of this object provides the label of the Module's test point select Digital parameter. |
| STR dualdrr2xenumTestpointSelect | 1.3.6.1.4.1.1166.6.1.2.35.3.2.35 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT dualdrr2xvalueTestpointSelect | 1.3.6.1.4.1.1166.6.1.2.35.3.2.36 | INTEGER | read-write | The value of this object reflects the setting of the test point selector for The Module. The user can enter a number from 1 to 4 |
| INT dualdrr2xstateflagTestpointSelect | 1.3.6.1.4.1.1166.6.1.2.35.3.2.37 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelOpFrequency | 1.3.6.1.4.1.1166.6.1.2.35.3.2.38 | DisplayString | read-only | The value of this object provides the label of the Module's active channels Digital parameter. |
| STR dualdrr2xenumOpFrequency | 1.3.6.1.4.1.1166.6.1.2.35.3.2.39 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT dualdrr2xvalueOpFrequency | 1.3.6.1.4.1.1166.6.1.2.35.3.2.40 | INTEGER | read-write | The value of this object reflects which channels are active for The Module. The user can enter a number from 1 to 4 |
| INT dualdrr2xstateflagOpFrequency | 1.3.6.1.4.1.1166.6.1.2.35.3.2.41 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelActChanSelect | 1.3.6.1.4.1.1166.6.1.2.35.3.2.42 | DisplayString | read-only | The value of this object provides the label of the Module's active channels Digital parameter. |
| STR dualdrr2xenumActChanSelect | 1.3.6.1.4.1.1166.6.1.2.35.3.2.43 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT dualdrr2xvalueActChanSelect | 1.3.6.1.4.1.1166.6.1.2.35.3.2.44 | INTEGER | read-write | The value of this object reflects which channels are active for The Module. The user can enter a number from 1 to 4 |
| INT dualdrr2xstateflagActChanSelect | 1.3.6.1.4.1.1166.6.1.2.35.3.2.45 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.35.3.2.46 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR dualdrr2xenumFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.35.3.2.47 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT dualdrr2xvalueFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.35.3.2.48 | INTEGER | read-write | The read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter |
| INT dualdrr2xstateflagFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.35.3.2.49 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| gx2dualdrr2xStatusTable | 1.3.6.1.4.1.1166.6.1.2.35.4 | not-accessible | This table contains gx2dualdrr2x specific status parameters with nominal and current values. | |
| gx2dualdrr2xStatusEntry | 1.3.6.1.4.1.1166.6.1.2.35.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2dualdrr2xStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.35.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR dualdrr2xlabelBoot | 1.3.6.1.4.1.1166.6.1.2.35.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status parameter. |
| INT dualdrr2xvalueBoot | 1.3.6.1.4.1.1166.6.1.2.35.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.35.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelFlash | 1.3.6.1.4.1.1166.6.1.2.35.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status parameter. |
| INT dualdrr2xvalueFlash | 1.3.6.1.4.1.1166.6.1.2.35.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.35.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.35.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT dualdrr2xvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.35.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.35.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.35.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT dualdrr2xvalueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.35.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.35.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.35.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Calibration Data Crc parameter. |
| INT dualdrr2xvalueCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.35.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.35.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.35.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Module Hardware Status parameter. |
| INT dualdrr2xvalueHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.35.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.35.4.3.19 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelCh1TripPointStatus | 1.3.6.1.4.1.1166.6.1.2.35.4.3.20 | DisplayString | read-only | The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip point value |
| INT dualdrr2xvalueCh1TripPointStatus | 1.3.6.1.4.1.1166.6.1.2.35.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagCh1TripPointStatus | 1.3.6.1.4.1.1166.6.1.2.35.4.3.22 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelLink1Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.23 | DisplayString | read-only | The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal. |
| INT dualdrr2xvalueLink1Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.24 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagLink1Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.25 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelCh2TripPointStatus | 1.3.6.1.4.1.1166.6.1.2.35.4.3.26 | DisplayString | read-only | The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip point value |
| INT dualdrr2xvalueCh2TripPointStatus | 1.3.6.1.4.1.1166.6.1.2.35.4.3.27 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagCh2TripPointStatus | 1.3.6.1.4.1.1166.6.1.2.35.4.3.28 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelLink2Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.29 | DisplayString | read-only | The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal. |
| INT dualdrr2xvalueLink2Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.30 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagLink2Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.31 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelDRT1Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.32 | DisplayString | read-only | The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal. |
| INT dualdrr2xvalueDRT1Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.33 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagDRT1Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.34 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelSFP0Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.35 | DisplayString | read-only | The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal. |
| INT dualdrr2xvalueSFP0Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.36 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagSFP0Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.37 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelDRT2Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.38 | DisplayString | read-only | The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal. |
| INT dualdrr2xvalueDRT2Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.39 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagDRT2Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.40 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR dualdrr2xlabelSFP1Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.41 | DisplayString | read-only | The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal. |
| INT dualdrr2xvalueSFP1Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.42 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT dualdrr2xstateflagSFP1Status | 1.3.6.1.4.1.1166.6.1.2.35.4.3.43 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| gx2dualdrr2xFactoryTable | 1.3.6.1.4.1.1166.6.1.2.35.5 | not-accessible | This table contains gx2dualdrr2x specific factory setting parameters with nominal and current values. | |
| gx2dualdrr2xFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.35.5.4 | not-accessible | This list contains Factory setting parameters and descriptions. | |
| INT gx2dualdrr2xFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.35.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT dualdrr2xbootControlByte | 1.3.6.1.4.1.1166.6.1.2.35.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT dualdrr2xbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.35.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT dualdrr2xbank1CRC | 1.3.6.1.4.1.1166.6.1.2.35.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT dualdrr2xbank2CRC | 1.3.6.1.4.1.1166.6.1.2.35.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT dualdrr2xprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.35.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT dualdrr2xfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.35.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT dualdrr2xcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.35.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated (1-factory, 2-alarm, 3-calibration). |
| INT dualdrr2xhourMeter | 1.3.6.1.4.1.1166.6.1.2.35.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT dualdrr2xflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.35.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 0 flash has been programmed. |
| INT dualdrr2xflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.35.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR dualdrr2xflashBankARev | 1.3.6.1.4.1.1166.6.1.2.35.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR dualdrr2xflashBankBRev | 1.3.6.1.4.1.1166.6.1.2.35.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
| STR dualdrr2xSubAgentRev | 1.3.6.1.4.1.1166.6.1.2.35.5.4.14 | DisplayString | read-only | This object provides the subagent revision of receiver module. |
| STR dualdrr2xFPGA0FwRev | 1.3.6.1.4.1.1166.6.1.2.35.5.4.15 | DisplayString | read-only | This object provides the Firmware revision of the first DRR FPGA. |
| STR dualdrr2xFPGA1FwRev | 1.3.6.1.4.1.1166.6.1.2.35.5.4.16 | DisplayString | read-only | This object provides the Firmware revision of the second DRR FPGA. |
| STR dualdrr2xDRT1SerialNo | 1.3.6.1.4.1.1166.6.1.2.35.5.4.17 | DisplayString | read-only | This object provides the Serial Number of the DRT attached to channel 1. |
| STR dualdrr2xDRT1SFPSerialNo | 1.3.6.1.4.1.1166.6.1.2.35.5.4.18 | DisplayString | read-only | This object provides the Serial Number of the SFP in the DRT attached to channel 1. |
| STR dualdrr2xDRT1SFPPartNo | 1.3.6.1.4.1.1166.6.1.2.35.5.4.19 | DisplayString | read-only | This object provides the Part number of the SFP in the DRT attached to channel 1. |
| STR dualdrr2xDRT1FwRev | 1.3.6.1.4.1.1166.6.1.2.35.5.4.20 | DisplayString | read-only | This object provides the Firmware revision of the DRT attached to channel 1. |
| STR dualdrr2xDRT1FpgaFwRev | 1.3.6.1.4.1.1166.6.1.2.35.5.4.21 | DisplayString | read-only | This object provides the Firmware revision of the FPGA in the DRT attached to channel 1. |
| STR dualdrr2xDRT2SerialNo | 1.3.6.1.4.1.1166.6.1.2.35.5.4.22 | DisplayString | read-only | This object provides the Serial Number of the DRT attached to channel 2 |
| STR dualdrr2xDRT2SFPSerialNo | 1.3.6.1.4.1.1166.6.1.2.35.5.4.23 | DisplayString | read-only | This object provides the Serial Number of the SFP in the DRT attached to channel 2 |
| STR dualdrr2xDRT2SFPPartNo | 1.3.6.1.4.1.1166.6.1.2.35.5.4.24 | DisplayString | read-only | This object provides the Part number of the SFP in the DRT attached to channel 2. |
| STR dualdrr2xDRT2FwRev | 1.3.6.1.4.1.1166.6.1.2.35.5.4.25 | DisplayString | read-only | This object provides the Firmware revision of the DRT attached to channel 2. |
| STR dualdrr2xDRT2FpgaFwRev | 1.3.6.1.4.1.1166.6.1.2.35.5.4.26 | DisplayString | read-only | This object provides the Firmware revision of the FPGA in the DRT attached to channel 2. |
RFC description
Manages OMNISTAR GX2 Dual Digital Return 2X receiver modules in HFC cable networks with device type descriptors.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (gx2dualdrr2x dual optical receiver module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.