OMNI-gx2drt4x-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2Drt4x FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. -- ********************************************************************* -- * * -- * REVISION history: * -- * MIB at Rev 0 to support Firmware at Rev A, March 10, 2005 * -- * * -- ********************************************************************* --DESCRIPTION -- OMNISTAR Digital Return Transmitter 4X Module MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2drt4x Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2drt4x device type. -- These parameters are common across all network elements -- from gx2drt4x device type. -- -- The gx2drt4x Network Elements subgroup is -- a list of gx2drt4x type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2drt4xTableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2Lmc type. -- -- Both groups are mandatory for management of gx2Lmc devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2drt4x Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2drt4x device type. -- These parameters are common across all network elements -- from gx2drt4x device type. gx2drt4xDescriptor OBJECT IDENTIFIER ::= {gx2Drt4x 1} --***************************************************************************** -- gx2drt4x Table -- Contains a list of all gx2drt4x type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2drt4xTableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2drt4x type. gx2drt4xAnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2drt4xAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains Gx2drt4x specific analog parameters with nominal,limits and current values." ::= { gx2Drt4x 2 } gx2drt4xAnalogEntry OBJECT-TYPE SYNTAX Gx2drt4xAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains the analog parameters and descriptions." INDEX { gx2drt4xAnalogTableIndex } ::= { gx2drt4xAnalogTable 1} --***************************************************************************** gx2drt4xDigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2drt4xDigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2drt4x specific digital parameters with nominal and current values." ::= { gx2Drt4x 3 } gx2drt4xDigitalEntry OBJECT-TYPE SYNTAX Gx2drt4xDigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital parameters and descriptions." INDEX { gx2drt4xDigitalTableIndex } ::= { gx2drt4xDigitalTable 2} --***************************************************************************** gx2drt4xStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2drt4xStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2drt4x specific status parameters with nominal and current values." ::= { gx2Drt4x 4 } gx2drt4xStatusEntry OBJECT-TYPE SYNTAX Gx2drt4xStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Status parameters and descriptions." INDEX { gx2drt4xStatusTableIndex } ::= { gx2drt4xStatusTable 3} --***************************************************************************** gx2drt4xFactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2drt4xFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2drt4x specific factory setting parameters with nominal and current values." ::= { gx2Drt4x 5 } gx2drt4xFactoryEntry OBJECT-TYPE SYNTAX Gx2drt4xFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Factory setting parameters and descriptions." INDEX { gx2drt4xFactoryTableIndex } ::= { gx2drt4xFactoryTable 4} --***************************************************************************** Gx2drt4xAnalogEntry ::= SEQUENCE { gx2drt4xAnalogTableIndex INTEGER, drt4xlabelRFAAttenuation DisplayString (SIZE (0..80)), drt4xuomRFAAttenuation DisplayString (SIZE (0..80)), drt4xmajorHighRFAAttenuation Float, drt4xmajorLowRFAAttenuation Float, drt4xminorHighRFAAttenuation Float, drt4xminorLowRFAAttenuation Float, drt4xvalueRFAAttenuation Float, drt4xstateFlagRFAAttenuation INTEGER, drt4xminValueRFAAttenuation Float, drt4xmaxValueRFAAttenuation Float, drt4xalarmStateRFAAttenuation INTEGER, drt4xlabelRFBAttenuation DisplayString (SIZE (0..80)), drt4xuomRFBAttenuation DisplayString (SIZE (0..80)), drt4xmajorHighRFBAttenuation Float, drt4xmajorLowRFBAttenuation Float, drt4xminorHighRFBAttenuation Float, drt4xminorLowRFBAttenuation Float, drt4xvalueRFBAttenuation Float, drt4xstateFlagRFBAttenuation INTEGER, drt4xminValueRFBAttenuation Float, drt4xmaxValueRFBAttenuation Float, drt4xalarmStateRFBAttenuation INTEGER, drt4xlabelRFCAttenuation DisplayString (SIZE (0..80)), drt4xuomRFCAttenuation DisplayString (SIZE (0..80)), drt4xmajorHighRFCAttenuation Float, drt4xmajorLowRFCAttenuation Float, drt4xminorHighRFCAttenuation Float, drt4xminorLowRFCAttenuation Float, drt4xvalueRFCAttenuation Float, drt4xstateFlagRFCAttenuation INTEGER, drt4xminValueRFCAttenuation Float, drt4xmaxValueRFCAttenuation Float, drt4xalarmStateRFCAttenuation INTEGER, drt4xlabelRFDAttenuation DisplayString (SIZE (0..80)), drt4xuomRFDAttenuation DisplayString (SIZE (0..80)), drt4xmajorHighRFDAttenuation Float, drt4xmajorLowRFDAttenuation Float, drt4xminorHighRFDAttenuation Float, drt4xminorLowRFDAttenuation Float, drt4xvalueRFDAttenuation Float, drt4xstateFlagRFDAttenuation INTEGER, drt4xminValueRFDAttenuation Float, drt4xmaxValueRFDAttenuation Float, drt4xalarmStateRFDAttenuation INTEGER, drt4xlabelLaserPowerMonitor DisplayString (SIZE (0..80)), drt4xuomLaserPowerMonitor DisplayString (SIZE (0..80)), drt4xmajorHighLaserPowerMonitor Float, drt4xmajorLowLaserPowerMonitor Float, drt4xminorHighLaserPowerMonitor Float, drt4xminorLowLaserPowerMonitor Float, drt4xvalueLaserPowerMonitor Float, drt4xstateFlagLaserPowerMonitor INTEGER, drt4xminValueLaserPowerMonitor Float, drt4xmaxValueLaserPowerMonitor Float, drt4xalarmStateLaserPowerMonitor INTEGER, drt4xlabelLaserBiasCurrent DisplayString (SIZE (0..80)), drt4xuomLaserBiasCurrent DisplayString (SIZE (0..80)), drt4xmajorHighLaserBiasCurrent Float, drt4xmajorLowLaserBiasCurrent Float, drt4xminorHighLaserBiasCurrent Float, drt4xminorLowLaserBiasCurrent Float, drt4xvalueLaserBiasCurrent Float, drt4xstateFlagLaserBiasCurrent INTEGER, drt4xminValueLaserBiasCurrent Float, drt4xmaxValueLaserBiasCurrent Float, drt4xalarmStateLaserBiasCurrent INTEGER, drt4xlabelLaserTECTemperature DisplayString (SIZE (0..80)), drt4xuomLaserTECTemperature DisplayString (SIZE (0..80)), drt4xmajorHighLaserTECTemperature Float, drt4xmajorLowLaserTECTemperature Float, drt4xminorHighLaserTECTemperature Float, drt4xminorLowLaserTECTemperature Float, drt4xvalueLaserTECTemperature Float, drt4xstateFlagLaserTECTemperature INTEGER, drt4xminValueLaserTECTemperature Float, drt4xmaxValueLaserTECTemperature Float, drt4xalarmStateLaserTECTemperature INTEGER, drt4xlabelLaserTECCurrent DisplayString (SIZE (0..80)), drt4xuomLaserTECCurrent DisplayString (SIZE (0..80)), drt4xmajorHighLaserTECCurrent Float, drt4xmajorLowLaserTECCurrent Float, drt4xminorHighLaserTECCurrent Float, drt4xminorLowLaserTECCurrent Float, drt4xvalueLaserTECCurrent Float, drt4xstateFlagLaserTECCurrent INTEGER, drt4xminValueLaserTECCurrent Float, drt4xmaxValueLaserTECCurrent Float, drt4xalarmStateLaserTECCurrent INTEGER, drt4xlabel12VCurrent DisplayString (SIZE (0..80)), drt4xuom12VCurrent DisplayString (SIZE (0..80)), drt4xmajorHigh12VCurrent Float, drt4xmajorLow12VCurrent Float, drt4xminorHigh12VCurrent Float, drt4xminorLow12VCurrent Float, drt4xvalue12VCurrent Float, drt4xstateFlag12VCurrent INTEGER, drt4xminValue12VCurrent Float, drt4xmaxValue12VCurrent Float, drt4xalarmState12VCurrent INTEGER, drt4xlabelModTemp DisplayString (SIZE (0..80)), drt4xuomModTemp DisplayString (SIZE (0..80)), drt4xmajorHighModTemp Float, drt4xmajorLowModTemp Float, drt4xminorHighModTemp Float, drt4xminorLowModTemp Float, drt4xvalueModTemp Float, drt4xstateFlagModTemp INTEGER, drt4xminValueModTemp Float, drt4xmaxValueModTemp Float, drt4xalarmStateModTemp INTEGER, drt4xlabelFanCurrent DisplayString (SIZE (0..80)), drt4xuomFanCurrent DisplayString (SIZE (0..80)), drt4xmajorHighFanCurrent Float, drt4xmajorLowFanCurrent Float, drt4xminorHighFanCurrent Float, drt4xminorLowFanCurrent Float, drt4xvalueFanCurrent Float, drt4xstateFlagFanCurrent INTEGER, drt4xminValueFanCurrent Float, drt4xmaxValueFanCurrent Float, drt4xalarmStateFanCurrent INTEGER } -- **************** Digital Parameters *********************** Gx2drt4xDigitalEntry ::= SEQUENCE { gx2drt4xDigitalTableIndex INTEGER, drt4xlabelBaseITUChannel DisplayString (SIZE (0..80)), drt4xenumBaseITUChannel DisplayString (SIZE (0..80)), drt4xvalueBaseITUChannel INTEGER, drt4xstateflagBaseITUChannel INTEGER, drt4xlabelITUChannelSetting DisplayString (SIZE (0..80)), drt4xenumITUChannelSetting DisplayString (SIZE (0..80)), drt4xvalueITUChannelSetting INTEGER, drt4xstateflagITUChannelSetting INTEGER, drt4xlabelOpticalPowerSetting DisplayString (SIZE (0..80)), drt4xenumOpticalPowerSetting DisplayString (SIZE (0..80)), drt4xvalueOpticalPowerSetting INTEGER, drt4xstateflagOpticalPowerSetting INTEGER, drt4xlabelLaserControl DisplayString (SIZE (0..80)), drt4xenumLaserControl DisplayString (SIZE (0..80)), drt4xvalueLaserControl INTEGER, drt4xstateflagLaserControl INTEGER, drt4xlabelFactoryDefaultReset DisplayString (SIZE (0..80)), drt4xenumFactoryDefaultReset DisplayString (SIZE (0..80)), drt4xvalueFactoryDefaultReset INTEGER, drt4xstateflagFactoryDefaultReset INTEGER } -- **************** Status Parameters ************************************ Gx2drt4xStatusEntry ::= SEQUENCE { gx2drt4xStatusTableIndex INTEGER, drt4xlabelBoot DisplayString (SIZE (0..80)), drt4xvalueBoot INTEGER, drt4xstateflagBoot INTEGER, drt4xlabelFlash DisplayString (SIZE (0..80)), drt4xvalueFlash INTEGER, drt4xstateflagFlash INTEGER, drt4xlabelFactoryDataCRC DisplayString (SIZE (0..80)), drt4xvalueFactoryDataCRC INTEGER, drt4xstateflagFactoryDataCRC INTEGER, drt4xlabelAlarmDataCrc DisplayString (SIZE (0..80)), drt4xvalueAlarmDataCrc INTEGER, drt4xstateflagAlarmDataCrc INTEGER, drt4xlabelCalibrationDataCrc DisplayString (SIZE (0..80)), drt4xvalueCalibrationDataCrc INTEGER, drt4xstateflagCalibrationDataCrc INTEGER, drt4xlabelHardwareStatus DisplayString (SIZE (0..80)), drt4xvalueHardwareStatus INTEGER, drt4xstateflagHardwareStatus INTEGER } -- *************************************************************************** -- ********************************** FACTORY ******************************** -- *************************************************************************** Gx2drt4xFactoryEntry ::= SEQUENCE { gx2drt4xFactoryTableIndex INTEGER, drt4xbootControlByte INTEGER, drt4xbootStatusByte INTEGER, drt4xbank1CRC INTEGER, drt4xbank2CRC INTEGER, drt4xprgEEPROMByte INTEGER, drt4xfactoryCRC INTEGER, drt4xcalculateCRC INTEGER, drt4xhourMeter INTEGER, drt4xflashPrgCntA INTEGER, drt4xflashPrgCntB INTEGER, drt4xflashBankARev DisplayString (SIZE (0..80)), drt4xflashBankBRev DisplayString (SIZE (0..80)), drt4xSubAgentRev DisplayString (SIZE (0..80)) } -- *************************************************************************** -- ********************************** ANALOG ********************************* -- *************************************************************************** gx2drt4xAnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2drt4xAnalogEntry 1} -- *************************************************************************** drt4xlabelRFAAttenuation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Channel A Attenuation Analog parameter." ::= { gx2drt4xAnalogEntry 2} drt4xuomRFAAttenuation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter." ::= { gx2drt4xAnalogEntry 3} drt4xmajorHighRFAAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 4} drt4xmajorLowRFAAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF) " ::= { gx2drt4xAnalogEntry 5} drt4xminorHighRFAAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. Set as the invalid float value (0xFFFFFFFF) " ::= { gx2drt4xAnalogEntry 6} drt4xminorLowRFAAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. Set as the invalid float value (0xFFFFFFFF) " ::= { gx2drt4xAnalogEntry 7} drt4xvalueRFAAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 8} drt4xstateFlagRFAAttenuation OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the RF Channel A Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xAnalogEntry 9} drt4xminValueRFAAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 10} drt4xmaxValueRFAAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive.which is 31.0 This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 11} drt4xalarmStateRFAAttenuation OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter." ::= { gx2drt4xAnalogEntry 12} -- *************************************************************************** drt4xlabelRFBAttenuation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Channel B Attenuation Analog parameter." ::= { gx2drt4xAnalogEntry 13} drt4xuomRFBAttenuation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter." ::= { gx2drt4xAnalogEntry 14} drt4xmajorHighRFBAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 15} drt4xmajorLowRFBAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 16} drt4xminorHighRFBAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 17} drt4xminorLowRFBAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 18} drt4xvalueRFBAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 19} drt4xstateFlagRFBAttenuation OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the RF Channel B Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xAnalogEntry 20} drt4xminValueRFBAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 21} drt4xmaxValueRFBAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive.which is 31.0 This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 22} drt4xalarmStateRFBAttenuation OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter." ::= { gx2drt4xAnalogEntry 23} -- *************************************************************************** drt4xlabelRFCAttenuation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Channel C Attenuation Analog parameter." ::= { gx2drt4xAnalogEntry 24} drt4xuomRFCAttenuation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the RF Channel C Attenuation Analog parameter." ::= { gx2drt4xAnalogEntry 25} drt4xmajorHighRFCAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 26} drt4xmajorLowRFCAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 27} drt4xminorHighRFCAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 28} drt4xminorLowRFCAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 29} drt4xvalueRFCAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 30} drt4xstateFlagRFCAttenuation OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the RF Channel C Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xAnalogEntry 31} drt4xminValueRFCAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the RF Channel C Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 32} drt4xmaxValueRFCAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the RF Channel C Attenuation Analog parameter can achive.which is 31.0 This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 33} drt4xalarmStateRFCAttenuation OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the RF Channel C Attenuation Analog parameter." ::= { gx2drt4xAnalogEntry 34} -- *************************************************************************** drt4xlabelRFDAttenuation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Channel D Attenuation Analog parameter." ::= { gx2drt4xAnalogEntry 35} drt4xuomRFDAttenuation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the RF Channel D Attenuation Analog parameter." ::= { gx2drt4xAnalogEntry 36} drt4xmajorHighRFDAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 37} drt4xmajorLowRFDAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 38} drt4xminorHighRFDAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 39} drt4xminorLowRFDAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 40} drt4xvalueRFDAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the RF Channel D Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 41} drt4xstateFlagRFDAttenuation OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the RF Channel D Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xAnalogEntry 42} drt4xminValueRFDAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the RF Channel D Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 43} drt4xmaxValueRFDAttenuation OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the RF Channel D Attenuation Analog parameter can achive.which is 31.0 This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 44} drt4xalarmStateRFDAttenuation OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the RF Channel D Attenuation Analog parameter." ::= { gx2drt4xAnalogEntry 45} -- *************************************************************************** drt4xlabelLaserPowerMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the trip point level Analog parameter." ::= { gx2drt4xAnalogEntry 46} drt4xuomLaserPowerMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the trip point level Analog parameter." ::= { gx2drt4xAnalogEntry 47} drt4xmajorHighLaserPowerMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the trip point level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 48} drt4xmajorLowLaserPowerMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the trip point level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 49} drt4xminorHighLaserPowerMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the trip point level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 50} drt4xminorLowLaserPowerMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the trip point level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. and set as the invalid float value (0xFFFFFFFF)" ::= { gx2drt4xAnalogEntry 51} drt4xvalueLaserPowerMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input level. When trip point mode is ALARM_SWITCH, when optical power level is lower than trip point level (Set by this parameter), trip point alarm will be generated and RF output impedance will be changed to high impedance as >8.2K. This trip point level value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 52} drt4xstateFlagLaserPowerMonitor OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the trip point level Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xAnalogEntry 53} drt4xminValueLaserPowerMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the trip point level Analog parameter can achive. The minimum value is -19dBm This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 54} drt4xmaxValueLaserPowerMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the trip point level Analog parameter can achive.which is -1dBm This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 55} drt4xalarmStateLaserPowerMonitor OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the trip point level Analog parameter." ::= { gx2drt4xAnalogEntry 56} -- *************************************************************************** drt4xlabelLaserBiasCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Current Analog parameter." ::= { gx2drt4xAnalogEntry 57} drt4xuomLaserBiasCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Current Analog parameter." ::= { gx2drt4xAnalogEntry 58} drt4xmajorHighLaserBiasCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 59} drt4xmajorLowLaserBiasCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 60} drt4xminorHighLaserBiasCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 61} drt4xminorLowLaserBiasCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 62} drt4xvalueLaserBiasCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 63} drt4xstateFlagLaserBiasCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xAnalogEntry 64} drt4xminValueLaserBiasCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 65} drt4xmaxValueLaserBiasCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 66} drt4xalarmStateLaserBiasCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Current Analog parameter." ::= { gx2drt4xAnalogEntry 67} -- *************************************************************************** drt4xlabelLaserTECTemperature OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser TEC Temperature Analog parameter." ::= { gx2drt4xAnalogEntry 68} drt4xuomLaserTECTemperature OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser TEC Temperature Analog parameter." ::= { gx2drt4xAnalogEntry 69} drt4xmajorHighLaserTECTemperature OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 70} drt4xmajorLowLaserTECTemperature OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 71} drt4xminorHighLaserTECTemperature OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 72} drt4xminorLowLaserTECTemperature OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 73} drt4xvalueLaserTECTemperature OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 74} drt4xstateFlagLaserTECTemperature OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xAnalogEntry 75} drt4xminValueLaserTECTemperature OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser TEC Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 76} drt4xmaxValueLaserTECTemperature OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser TEC Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 77} drt4xalarmStateLaserTECTemperature OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser TEC Temperature Analog parameter." ::= { gx2drt4xAnalogEntry 78} -- *************************************************************************** drt4xlabelLaserTECCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser TEC Current Analog parameter." ::= { gx2drt4xAnalogEntry 79} drt4xuomLaserTECCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser TEC Current Analog parameter." ::= { gx2drt4xAnalogEntry 80} drt4xmajorHighLaserTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 81} drt4xmajorLowLaserTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 82} drt4xminorHighLaserTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 83} drt4xminorLowLaserTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 84} drt4xvalueLaserTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 85} drt4xstateFlagLaserTECCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xAnalogEntry 86} drt4xminValueLaserTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 87} drt4xmaxValueLaserTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 88} drt4xalarmStateLaserTECCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser TEC Current Analog parameter." ::= { gx2drt4xAnalogEntry 89} -- *************************************************************************** drt4xlabel12VCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the 12v power supply Current Analog parameter." ::= { gx2drt4xAnalogEntry 90} drt4xuom12VCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter." ::= { gx2drt4xAnalogEntry 91} drt4xmajorHigh12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 92} drt4xmajorLow12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 93} drt4xminorHigh12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 94} drt4xminorLow12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 95} drt4xvalue12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the 12v power supply Current parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 96} drt4xstateFlag12VCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the 12v power supply Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xAnalogEntry 97} drt4xminValue12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 98} drt4xmaxValue12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 99} drt4xalarmState12VCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter." ::= { gx2drt4xAnalogEntry 100} -- *************************************************************************** drt4xlabelModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2drt4xAnalogEntry 101} drt4xuomModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2drt4xAnalogEntry 102} drt4xmajorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 103} drt4xmajorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 104} drt4xminorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 105} drt4xminorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 106} drt4xvalueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 107} drt4xstateFlagModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xAnalogEntry 108} drt4xminValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 109} drt4xmaxValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 110} drt4xalarmStateModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2drt4xAnalogEntry 111} -- *************************************************************************** drt4xlabelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2drt4xAnalogEntry 112} drt4xuomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter." ::= { gx2drt4xAnalogEntry 113} drt4xmajorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 114} drt4xmajorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 115} drt4xminorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 116} drt4xminorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 117} drt4xvalueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 118} drt4xstateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xAnalogEntry 119} drt4xminValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 120} drt4xmaxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2drt4xAnalogEntry 121} drt4xalarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2drt4xAnalogEntry 122} -- *************************************************************************** -- ********************************** DIGITAL ******************************** -- *************************************************************************** gx2drt4xDigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2drt4xDigitalEntry 1} -- *************************************************************************** drt4xlabelBaseITUChannel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Base ITU Channel Digital parameter." ::= { gx2drt4xDigitalEntry 2} drt4xenumBaseITUChannel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. " ::= { gx2drt4xDigitalEntry 3} drt4xvalueBaseITUChannel OBJECT-TYPE SYNTAX INTEGER{ ch20(1), ch24(2), ch28(3), ch32(4), ch36(5), ch40(6), ch44(7), ch48(8), ch52(9), ch56(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the value of the Base ITU Channel. There are 10 possible value: 1-ch20, 2-ch24, 3-ch28, 4-ch32, 5-ch36, 6-ch40, 7-ch44, 8-ch48, 9-ch52, 10-ch56." ::= { gx2drt4xDigitalEntry 4} drt4xstateflagBaseITUChannel OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xDigitalEntry 5} -- *************************************************************************** drt4xlabelITUChannelSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-write STATUS optional DESCRIPTION "The value of this object provides the label of the ITU Channel Setting Digital parameter." ::= { gx2drt4xDigitalEntry 6} drt4xenumITUChannelSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. " ::= { gx2drt4xDigitalEntry 7} drt4xvalueITUChannelSetting OBJECT-TYPE SYNTAX INTEGER{ base(1), basePlus1(2), basePlus2(3), basePlus3(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the value of the ITU Channel Setting. There are 4 possible value: 1-base (base ITU channel), 2-basePlus1 (base ITU Channel + 1), 3-basePlus2 (base ITU Channel + 2), and 4-basePlus3 (base ITU Channel + 3)." ::= { gx2drt4xDigitalEntry 8} drt4xstateflagITUChannelSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xDigitalEntry 9} -- *************************************************************************** drt4xlabelOpticalPowerSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Setting Digital parameter. This parameter defines the operating power level of the DRT-4X" ::= { gx2drt4xDigitalEntry 10} drt4xenumOpticalPowerSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. " ::= { gx2drt4xDigitalEntry 11} drt4xvalueOpticalPowerSetting OBJECT-TYPE SYNTAX INTEGER{ low(1), high(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the setting of the Optical Power. There are two possible value: 1-low, and 2-high." ::= { gx2drt4xDigitalEntry 12} drt4xstateflagOpticalPowerSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xDigitalEntry 13} -- *************************************************************************** drt4xlabelLaserControl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Control Digital parameter. The Laser Control allows the DRT-4X laser to be turned off or on." ::= { gx2drt4xDigitalEntry 14} drt4xenumLaserControl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. " ::= { gx2drt4xDigitalEntry 15} drt4xvalueLaserControl OBJECT-TYPE SYNTAX INTEGER{ off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object represents the Laser Control. There are two possible values: 1-off, and 2-on." ::= { gx2drt4xDigitalEntry 16} drt4xstateflagLaserControl OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xDigitalEntry 17} -- *************************************************************************** drt4xlabelFactoryDefaultReset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2drt4xDigitalEntry 18} drt4xenumFactoryDefaultReset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2drt4xDigitalEntry 19} drt4xvalueFactoryDefaultReset OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2drt4xDigitalEntry 20} drt4xstateflagFactoryDefaultReset OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xDigitalEntry 21} -- *************************************************************************** -- ********************************** STATUS ********************************* -- *************************************************************************** gx2drt4xStatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2drt4xStatusEntry 1} -- *************************************************************************** drt4xlabelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status parameter." ::= { gx2drt4xStatusEntry 2} drt4xvalueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2drt4xStatusEntry 3} drt4xstateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xStatusEntry 4} -- *************************************************************************** drt4xlabelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status parameter." ::= { gx2drt4xStatusEntry 5} drt4xvalueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2drt4xStatusEntry 6} drt4xstateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xStatusEntry 7} -- *************************************************************************** drt4xlabelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2drt4xStatusEntry 8} drt4xvalueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2drt4xStatusEntry 9} drt4xstateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xStatusEntry 10} -- *************************************************************************** drt4xlabelAlarmDataCrc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2drt4xStatusEntry 11} drt4xvalueAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2drt4xStatusEntry 12} drt4xstateflagAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xStatusEntry 13} -- *************************************************************************** drt4xlabelCalibrationDataCrc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Calibration Data CRC parameter." ::= { gx2drt4xStatusEntry 14} drt4xvalueCalibrationDataCrc OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2drt4xStatusEntry 15} drt4xstateflagCalibrationDataCrc OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xStatusEntry 16} -- *************************************************************************** drt4xlabelHardwareStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Hardware Status parameter." ::= { gx2drt4xStatusEntry 17} drt4xvalueHardwareStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2drt4xStatusEntry 18} drt4xstateflagHardwareStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2drt4xStatusEntry 19} -- ************ FACTORY DATA **************** gx2drt4xFactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2drt4xFactoryEntry 1} drt4xbootControlByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2drt4xFactoryEntry 2} drt4xbootStatusByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot" ::= { gx2drt4xFactoryEntry 3} drt4xbank1CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0." ::= { gx2drt4xFactoryEntry 4} drt4xbank2CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1." ::= { gx2drt4xFactoryEntry 5} drt4xprgEEPROMByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2drt4xFactoryEntry 6} drt4xfactoryCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2drt4xFactoryEntry 7} drt4xcalculateCRC OBJECT-TYPE SYNTAX INTEGER { factory(1), alarm(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which of the Emnums will have the CRC calculated." ::= { gx2drt4xFactoryEntry 8} drt4xhourMeter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2drt4xFactoryEntry 9} drt4xflashPrgCntA OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 0 flash has been programmed." ::= { gx2drt4xFactoryEntry 10} drt4xflashPrgCntB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2drt4xFactoryEntry 11} drt4xflashBankARev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 0." ::= { gx2drt4xFactoryEntry 12} drt4xflashBankBRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 1." ::= { gx2drt4xFactoryEntry 13} drt4xSubAgentRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the subagent revision of receiver module." ::= { gx2drt4xFactoryEntry 14} -- *************************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- *************************************************************************** -- *************************************************************************** -- *************************************************************************** -- Digital Return Transmitter 4X Module traps -- *************************************************************************** trapdrt4xConfigChangeInteger TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapdrt4xConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapdrt4xModulePlus12CurrentAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Module +12V Supply Current goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapdrt4xModuleTempAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapdrt4xFanCurrentAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 5 trapdrt4xFlashAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the detects an error during Flash memory operations." ::= 6 trapdrt4xBankBootAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the detects an error while booting from bank 0 or bank 1." ::= 7 trapdrt4xFactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Data CRC is incorrect." ::= 8 trapdrt4xAlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Alarm Data CRC is incorrect." ::= 9 trapdrt4xCalibrationDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Calibration Data CRC is incorrect." ::= 10 trapdrt4xHardwareErrorAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when hardware is abnormal." ::= 11 trapdrt4xOpticalPowerAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the optical power is out of range." ::= 12 trapdrt4xTECTemperatureAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the TEC Temperature is out of range." ::= 13 trapdrt4xTECCurrentAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the TEC Current is out of range." ::= 14 trapdrt4xLaserBiasCurrentAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Bias Current is out of range." ::= 15 trapdrt4xResetFactoryDefaultAlarm TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Default Reset occurs." ::= 16 trapdrt4xLaserOnOffInfo TRAP-TYPE ENTERPRISE gx2Drt4x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the When the Laser turns on/off." ::= 17 END