All MIBs › OMNI-gx2drt4x-MIB › drt4xalarmStateLaserTECTemperature
drt4xalarmStateLaserTECTemperature
Module: OMNI-gx2drt4x-MIB
OID (symbolic): OMNI-gx2drt4x-MIB::drt4xalarmStateLaserTECTemperature
OID (numeric): 1.3.6.1.4.1.1166.6.1.2.25.2.1.78
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The value of this object provides the curent alarm state of the Laser TEC Temperature Analog parameter.
What is drt4xalarmStateLaserTECTemperature?
This is the current alarm severity for laser TEC (thermoelectric cooler) temperature: noAlarm, majorLowAlarm, minorLowAlarm, minorHighAlarm, majorHighAlarm, or informational. A monitoring system reads this directly instead of re-evaluating the raw value against the threshold objects, since the module has already done that comparison internally. An admin scanning for problems can poll just this one object per parameter to know whether it currently needs attention.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.25.2.1.78 snmpwalk -v2c -c public <target> OMNI-gx2drt4x-MIB::drt4xalarmStateLaserTECTemperature
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.25.2.1.78.1 snmpget -v2c -c public <target> OMNI-gx2drt4x-MIB::drt4xalarmStateLaserTECTemperature.1
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRT4X downstream RF transmitter card) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2drt4x-MIB::drt4xalarmStateLaserTECTemperature OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRT4X downstream RF transmitter card) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1166 | gi | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6 | motproxies | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6.1 | hfc | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2 | hfcDevices | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2.25 | gx2Drt4x | GX2HFC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.25.2 | gx2drt4xAnalogTable | OMNI-gx2drt4x-MIB |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1 | gx2drt4xAnalogEntry | OMNI-gx2drt4x-MIB |
| 1.3.6.1.4.1.1166.6.1.2.25.2.1.78 | drt4xalarmStateLaserTECTemperature | OMNI-gx2drt4x-MIB |