LaserJet5Si-MIB :: background_status_msg_line1_part1

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsLaserJet5Si-MIBbackground_status_msg_line1_part1

background_status_msg_line1_part1

Module: LaserJet5Si-MIB

OID (symbolic): LaserJet5Si-MIB::background_status_msg_line1_part1

OID (numeric): 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1.1

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is '00 READY'. Additional information: This object allows a message to be displayed when it is the highest priority message. Setting this objedct does not guarantee the message will be displayed; and reading it returns the value last written, not the currently displayed message (use prtConsoleDisplayBufferText to read the display). The priority assigned for displaying this message is one lower than the PJL RDYMSG. To clear the message, write a null string to this object. While the object prtConsoleLocalization controls the localization and symbol set usage of printer generated messages, this object's message is displayed using the symbol set specified with the string. The default symbol set is Roman-8; additional legal symbol sets are ISOLatin5, ISOLatin2 and Windows31J. When either BACKGROUND-STATUS-MSG-LINE1-PART1 or BACKGROUND-STATUS-MSG-LINE2-PART1 contains a non-null value, both will be displayed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1.1
snmpwalk -v2c -c public <target> LaserJet5Si-MIB::background_status_msg_line1_part1

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1.1.1
snmpget -v2c -c public <target> LaserJet5Si-MIB::background_status_msg_line1_part1.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1.1.1 s <value>

Start monitoring HP LaserJet 5Si laser printer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LaserJet5Si-MIB::background_status_msg_line1_part1 OID value, configure state conditions and alerts, and monitor any HP LaserJet 5Si laser printer from a single console.

OID Breakdown

Upper-level ancestors (17 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.3hpsystemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9net_peripheralCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4netdmCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2dmCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1deviceCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1.1systemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1.1.2status_systemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37background_messageCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1background_message1CLJ8500-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1.1background_status_msg_line1_part1LaserJet5Si-MIB