LIEBERT-GP-ENVIRONMENTAL-MIB

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LIEBERT-GP-ENVIRONMENTAL-MIB

Organization: Liebert Corporation

Last Updated: 2008-11-17

Category: Domain: Environmental Monitoring, Domain: Power/UPS, Vendor: Liebert

Description: Defines SNMP objects for monitoring environmental conditions (temperature, humidity, airflow) on Liebert precision cooling and environmental control systems.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is LIEBERT-GP-ENVIRONMENTAL-MIB?

LIEBERT-GP-ENVIRONMENTAL-MIB is a Liebert (Vertiv) MIB for their precision cooling and environmental control units used in data centers, part of the data-center facilities/environmental monitoring technology area. It exposes environmental control mode and state data covering cooling, heating, humidifying, dehumidifying, economizer (econo cycle) operation, and fan state, along with alarm outputs and cooling/heating capacity levels. This MIB is squarely aimed at monitoring the operational/hardware status of environmental equipment: lgpEnvStateCooling, lgpEnvStateHeating, lgpEnvStateFan and lgpEnvStateGeneralAlarmOutput reveal whether the unit's core subsystems are actively running or in alarm, while lgpEnvStateCoolingCapacity/HeatingCapacity indicate how hard the unit is working, all critical for preventing data-center overheating incidents. It is a self-contained Liebert enterprise MIB not dependent on other vendor MIBs beyond standard SNMP conventions. It is typically deployed on Liebert/Vertiv computer room air conditioning (CRAC) or precision cooling units in data center and telecom equipment room environments. Engineers can download the LIEBERT-GP-ENVIRONMENTAL-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in LIEBERT-GP-ENVIRONMENTAL-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Liebert/Vertiv precision cooling units (CRAC/CRAH systems)

Monitoring Examples

A facilities engineer would poll lgpEnvStateCooling and lgpEnvStateCoolingCapacity together to see whether the CRAC unit is actively cooling and how much of its capacity is in use, flagging a unit running at sustained high capacity as an early warning of insufficient cooling headroom. lgpEnvStateGeneralAlarmOutput would be checked as a summary alarm flag, and lgpEnvStateFan polled to confirm airflow is active; a fan state showing off while cooling state shows active would indicate a fan failure needing immediate attention. lgpEnvTemperatureControlMode would be reviewed to confirm the unit is in its intended automatic control mode rather than a manual override.

What Can Be Monitored

  • cooling/heating/humidifying/dehumidifying state
  • economizer (econo cycle) state
  • fan operating state
  • general alarm output
  • cooling and heating capacity utilization
  • temperature control mode
Imported Objects

From LIEBERT-GP-REGISTRATION-MIB

lgpEnvironmentalOBJECT-IDENTITY
liebertEnvironmentalModuleRegOBJECT-IDENTITY

From SNMPv2-SMI

Integer32
MODULE-IDENTITY
OBJECT-IDENTITY
OBJECT-TYPE
Unsigned32

How to Use in IPNetwork Monitor

Example using lgpEnvStateSystem OID:

Select a Liebert/Vertiv precision cooling unit (CRAC/CRAH) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type lgpEnvStateSystem into the Find box to locate it in the OID tree, then select it and click OK. The present state of the system. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'on', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Provides environmental monitoring for Liebert power and cooling management equipment.

Start monitoring Liebert/Vertiv precision cooling unit (CRAC/CRAH) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download LIEBERT-GP-ENVIRONMENTAL-MIB