LIEBERT-GP-ENVIRONMENTAL-MIB :: lgpEnvTemperatureMeasurementDegC

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LIEBERT-GP-ENVIRONMENTAL-MIB › lgpEnvTemperatureMeasurementDegC

lgpEnvTemperatureMeasurementDegC

Module: LIEBERT-GP-ENVIRONMENTAL-MIB

OID (symbolic): LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvTemperatureMeasurementDegC

OID (numeric): 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The measured temperature value.

What is lgpEnvTemperatureMeasurementDegC?

The measured temperature value, in whole degrees Celsius, for the point identified by lgpEnvTemperatureDescrDegC in the same table row. Admins read this as the primary current-temperature reading for whichever sensor point that row represents, on metric-configured units.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.3
snmpwalk -v2c -c public <target> LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvTemperatureMeasurementDegC

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.3.1
snmpget -v2c -c public <target> LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvTemperatureMeasurementDegC.1

Start monitoring Liebert/Vertiv precision cooling unit (CRAC/CRAH) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvTemperatureMeasurementDegC OID value, configure state conditions and alerts, and monitor any Liebert/Vertiv precision cooling unit (CRAC/CRAH) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42liebertGlobalProductsLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3lgpFoundationLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3.4lgpEnvironmentalLIEBERT-GP-REGISTRATION-MIB
Numeric OIDNameModule
1.3.6.1.4.1.476.1.42.3.4.1lgpEnvTemperatureLIEBERT-GP-ENVIRONMENTAL-MIB
1.3.6.1.4.1.476.1.42.3.4.1.3lgpEnvTemperatureCelsiusLIEBERT-GP-ENVIRONMENTAL-MIB
1.3.6.1.4.1.476.1.42.3.4.1.3.3lgpEnvTemperatureTableDegCLIEBERT-GP-ENVIRONMENTAL-MIB
1.3.6.1.4.1.476.1.42.3.4.1.3.3.1lgpEnvTemperatureEntryDegCLIEBERT-GP-ENVIRONMENTAL-MIB
1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.3lgpEnvTemperatureMeasurementDegCLIEBERT-GP-ENVIRONMENTAL-MIB