Module: LIEBERT-GP-ENVIRONMENTAL-MIB

OID (symbolic): LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvConfigSleepMode

OID (numeric): 1.3.6.1.4.1.476.1.42.3.4.4.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The configured mode of the device's sleep function. If 'enabled', the device will sleep, or not operate, for each 'lgpEnvSleepDay' that is enabled and also during the periods defined in the 'lgpEnvSleepTimeTable' each day. If 'disabled', the device will operate continually and not sleep at all. If 'auto', the device will sleep, or not operate, for each 'lgpEnvSleepDay' that is enabled and also during the periods defined in the 'lgpEnvSleepTimeTable' each day unless the environmental conditions fall outside the desired operation ranges.

What is lgpEnvConfigSleepMode?

The configured mode of the unit's sleep function: enabled (sleeps on each configured sleep day/interval), disabled (runs continuously, never sleeps), or auto (sleeps as scheduled unless environmental conditions fall outside the desired range, in which case it overrides sleep to keep controlling). Admins use auto to get energy savings from scheduled sleep while still protecting against conditions drifting out of bounds.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.4.4.17
snmpwalk -v2c -c public <target> LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvConfigSleepMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.4.4.17.1
snmpget -v2c -c public <target> LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvConfigSleepMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.476.1.42.3.4.4.17.1 i <value>

Start monitoring Liebert/Vertiv precision cooling unit (CRAC/CRAH) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvConfigSleepMode OID value, configure state conditions and alerts, and monitor any Liebert/Vertiv precision cooling unit (CRAC/CRAH) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42liebertGlobalProductsLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3lgpFoundationLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3.4lgpEnvironmentalLIEBERT-GP-REGISTRATION-MIB
Numeric OIDNameModule
1.3.6.1.4.1.476.1.42.3.4.4lgpEnvConfigLIEBERT-GP-ENVIRONMENTAL-MIB
1.3.6.1.4.1.476.1.42.3.4.4.17lgpEnvConfigSleepModeLIEBERT-GP-ENVIRONMENTAL-MIB