Description: The measured temperature value.

What is lgpEnvTemperatureMeasurementTenthsDegF?

The measured temperature value for this row's point, expressed in tenths of a degree Fahrenheit for finer resolution than lgpEnvTemperatureMeasurementDegF. Admins use this when a monitoring tool needs more precision than whole-degree readings provide, for example detecting a slow upward drift.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.50
snmpwalk -v2c -c public <target> LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvTemperatureMeasurementTenthsDegF

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.50.1
snmpget -v2c -c public <target> LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvTemperatureMeasurementTenthsDegF.1

Start monitoring Liebert/Vertiv precision cooling unit (CRAC/CRAH) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvTemperatureMeasurementTenthsDegF OID value, configure state conditions and alerts, and monitor any Liebert/Vertiv precision cooling unit (CRAC/CRAH) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42liebertGlobalProductsLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3lgpFoundationLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3.4lgpEnvironmentalLIEBERT-GP-REGISTRATION-MIB
Numeric OIDNameModule
1.3.6.1.4.1.476.1.42.3.4.1lgpEnvTemperatureLIEBERT-GP-ENVIRONMENTAL-MIB
1.3.6.1.4.1.476.1.42.3.4.1.2lgpEnvTemperatureFahrenheitLIEBERT-GP-ENVIRONMENTAL-MIB
1.3.6.1.4.1.476.1.42.3.4.1.2.3lgpEnvTemperatureTableDegFLIEBERT-GP-ENVIRONMENTAL-MIB
1.3.6.1.4.1.476.1.42.3.4.1.2.3.1lgpEnvTemperatureEntryDegFLIEBERT-GP-ENVIRONMENTAL-MIB
1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.50lgpEnvTemperatureMeasurementTenthsDegFLIEBERT-GP-ENVIRONMENTAL-MIB