LIEBERT-GP-ENVIRONMENTAL-MIB :: lgpEnvStateSystem

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LIEBERT-GP-ENVIRONMENTAL-MIB › lgpEnvStateSystem

lgpEnvStateSystem

Module: LIEBERT-GP-ENVIRONMENTAL-MIB

OID (symbolic): LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvStateSystem

OID (numeric): 1.3.6.1.4.1.476.1.42.3.4.3.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The present state of the system.

What is lgpEnvStateSystem?

Reports the present operating state of the whole environmental unit: on, off, or standby. Admins poll this as a top-level health check to confirm a CRAC/CRAH unit is actively running rather than sitting idle or in standby during a cooling capacity review.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.4.3.1
snmpwalk -v2c -c public <target> LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvStateSystem

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.4.3.1.1
snmpget -v2c -c public <target> LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvStateSystem.1

Start monitoring Liebert/Vertiv precision cooling unit (CRAC/CRAH) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-ENVIRONMENTAL-MIB::lgpEnvStateSystem OID value, configure state conditions and alerts, and monitor any Liebert/Vertiv precision cooling unit (CRAC/CRAH) from a single console.

How to Use in IPNetwork Monitor

Select a Liebert/Vertiv precision cooling unit (CRAC/CRAH) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type lgpEnvStateSystem into the Find box to locate it in the OID tree, then select it and click OK. The present state of the system. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'on', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42liebertGlobalProductsLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3lgpFoundationLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3.4lgpEnvironmentalLIEBERT-GP-REGISTRATION-MIB
Numeric OIDNameModule
1.3.6.1.4.1.476.1.42.3.4.3lgpEnvStateLIEBERT-GP-ENVIRONMENTAL-MIB
1.3.6.1.4.1.476.1.42.3.4.3.1lgpEnvStateSystemLIEBERT-GP-ENVIRONMENTAL-MIB