All MIBs › GE-PARALLELUPS
Description: GE-PARALLELUPS module
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is GE-PARALLELUPS?
GE-PARALLELUPS is a General Electric (enterprise OID 818) proprietary MIB reporting status for parallel-redundant UPS installations, built on generic UPS objects modeled after RFC 1628. Its objects cover a discovered-UPS bitmask, request/reply packet objects, and generic UPS identity (manufacturer, model, software version, agent version, name, attached devices, serial number, protocol version, operating time), battery status (status, seconds on battery, estimated minutes/charge remaining, voltage, current, temperature), and an input-line table (bad-line count, line count, per-line frequency). As a status/performance MIB it lets an administrator watch battery runtime and input-line quality across a GE parallel UPS bank. It is deployed on GE parallel-redundant UPS installations. Engineers can download the GE-PARALLELUPS file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in GE-PARALLELUPS. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- GE parallel-redundant UPS installations
Monitoring Examples
An administrator checks upsEstimatedMinutesRemaining-gen and upsBatteryStatus-gen to confirm runway remaining during a power outage on a GE parallel UPS installation.
What Can Be Monitored
- battery runtime and input-line quality
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-SMI
| Counter32 | |
| Gauge32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE | |
| enterprises |
From SNMPv2-TC
| AutonomousType | |
| DisplayString | |
| TEXTUAL-CONVENTION | |
| TestAndIncr | |
| TimeInterval | |
| TimeStamp |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| imv | 1.3.6.1.4.1.818 | |||
| geHardware | 1.3.6.1.4.1.818.1 | |||
| geUPS | 1.3.6.1.4.1.818.1.1 | |||
| I32 geDiscoveredUPSsMask | 1.3.6.1.4.1.818.1.1.1 | Integer32 | read-only | Reading this variable returns bit mask indicating which UPSs in a parallel system are alive. Management software should poll only these UPSs on their snmp branches 11-18 as follows: 1 FirstUPS alive 2 SecondUPS alive 4 ThirdUPS alive 8 FourthUPS alive 16 FifthUPS alive 32 SixthUPS alive 64 SeventhUPS alive 128 EigthUPS alive Since the management software should always monitor the GenericUPS branch (10), this value has no meaning for single upses (which provide values on that snmp branch), and should be set to zero in that case. |
| STR geRequestPacket | 1.3.6.1.4.1.818.1.1.2 | DisplayString | read-write | Put the string, formatted as a IMV/CP4 packet, directly to internally RS485 bus. This OID could be used for accede directly to the internally RS485 bus from a remote place. |
| STR geReplyPacket | 1.3.6.1.4.1.818.1.1.3 | DisplayString | read-only | Contain the reply of the IMV/CP4 request packet sent using the OID geRequestPacket. Every time that a write command has be made at the OID ge RequestPacket, the value of this OID is erased. |
| geGenericUPS | 1.3.6.1.4.1.818.1.1.10 | |||
| upsIdent_gen | 1.3.6.1.4.1.818.1.1.10.1 | |||
| STR upsIdentManufacturer_gen | 1.3.6.1.4.1.818.1.1.10.1.1 | DisplayString | read-only | The name of the UPS manufacturer.(*) |
| STR upsIdentModel_gen | 1.3.6.1.4.1.818.1.1.10.1.2 | DisplayString | read-only | The UPS Model designation.(*) |
| STR upsIdentUPSSoftwareVersion_gen | 1.3.6.1.4.1.818.1.1.10.1.3 | DisplayString | read-only | The UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.(*) |
| STR upsIdentAgentSoftwareVersion_gen | 1.3.6.1.4.1.818.1.1.10.1.4 | DisplayString | read-only | The UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.(*) |
| STR upsIdentName_gen | 1.3.6.1.4.1.818.1.1.10.1.5 | DisplayString | read-write | A string identifying the UPS. This object should be set by the administrator.(*) |
| STR upsIdentAttachedDevices_gen | 1.3.6.1.4.1.818.1.1.10.1.6 | DisplayString | read-write | A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.(*) |
| STR upsIdentUPSSerialNumber_gen | 1.3.6.1.4.1.818.1.1.10.1.7 | DisplayString | read-only | The UPS serial number |
| STR upsIdentComProtVersion_gen | 1.3.6.1.4.1.818.1.1.10.1.8 | DisplayString | read-only | The IMV communication protocol version |
| NUM upsIdentOperatingTime_gen | 1.3.6.1.4.1.818.1.1.10.1.9 | NonNegativeInteger32 | read-only | The present value of the operating time. total 'on' time since UPS manufactured |
| upsBattery_gen | 1.3.6.1.4.1.818.1.1.10.2 | |||
| INT upsBatteryStatus_gen | 1.3.6.1.4.1.818.1.1.10.2.1 | INTEGER | read-only | The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).(*) |
| NUM upsSecondsOnBattery_gen | 1.3.6.1.4.1.818.1.1.10.2.2 | NonNegativeInteger32 | read-only | If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.(*) |
| NUM upsEstimatedMinutesRemaining_gen | 1.3.6.1.4.1.818.1.1.10.2.3 | PositiveInteger32 | read-only | An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.(*) |
| I32 upsEstimatedChargeRemaining_gen | 1.3.6.1.4.1.818.1.1.10.2.4 | Integer32 | read-only | An estimate of the battery charge remaining expressed as a percent of full charge.(*) |
| NUM upsBatteryVoltage_gen | 1.3.6.1.4.1.818.1.1.10.2.5 | NonNegativeInteger32 | read-only | The magnitude of the present battery voltage.(*) |
| I32 upsBatteryCurrent_gen | 1.3.6.1.4.1.818.1.1.10.2.6 | Integer32 | read-only | The present battery current.(*) |
| I32 upsBatteryTemperature_gen | 1.3.6.1.4.1.818.1.1.10.2.7 | Integer32 | read-only | The ambient temperature at or near the UPS Battery casing.(*) |
| upsInput_gen | 1.3.6.1.4.1.818.1.1.10.3 | |||
| C32 upsInputLineBads_gen | 1.3.6.1.4.1.818.1.1.10.3.1 | Counter32 | read-only | A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.(*) |
| NUM upsInputNumLines_gen | 1.3.6.1.4.1.818.1.1.10.3.2 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This variable indicates the number of rows in the input table.(*) |
| upsInputTable_gen | 1.3.6.1.4.1.818.1.1.10.3.3 | not-accessible | A list of input table entries. The number of entries is given by the value of upsInputNumLines.(*) | |
| upsInputEntry_gen | 1.3.6.1.4.1.818.1.1.10.3.3.1 | not-accessible | An entry containing information applicable to a particular input line.(*) | |
| NUM upsInputLineIndex_gen | 1.3.6.1.4.1.818.1.1.10.3.3.1.1 | PositiveInteger32 | not-accessible | The input line identifier.(*) |
| NUM upsInputFrequency_gen | 1.3.6.1.4.1.818.1.1.10.3.3.1.2 | NonNegativeInteger32 | read-only | The present input frequency.(*) |
| NUM upsInputVoltage_gen | 1.3.6.1.4.1.818.1.1.10.3.3.1.3 | NonNegativeInteger32 | read-only | The magnitude of the present input voltage.(*) |
| NUM upsInputCurrent_gen | 1.3.6.1.4.1.818.1.1.10.3.3.1.4 | NonNegativeInteger32 | read-only | The magnitude of the present input current.(*) |
| NUM upsInputTruePower_gen | 1.3.6.1.4.1.818.1.1.10.3.3.1.5 | NonNegativeInteger32 | read-only | The magnitude of the present input true power.(*) |
| NUM upsInputVoltageMin_gen | 1.3.6.1.4.1.818.1.1.10.3.3.1.6 | NonNegativeInteger32 | read-only | The lowest magnitude of the input voltage since last read out. |
| NUM upsInputVoltageMax_gen | 1.3.6.1.4.1.818.1.1.10.3.3.1.7 | NonNegativeInteger32 | read-only | The highest magnitude of the input voltage since last read out. |
| upsOutput_gen | 1.3.6.1.4.1.818.1.1.10.4 | |||
| INT upsOutputSource_gen | 1.3.6.1.4.1.818.1.1.10.4.1 | INTEGER | read-only | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.(*) |
| NUM upsOutputFrequency_gen | 1.3.6.1.4.1.818.1.1.10.4.2 | NonNegativeInteger32 | read-only | The present output frequency.(*) |
| NUM upsOutputNumLines_gen | 1.3.6.1.4.1.818.1.1.10.4.3 | NonNegativeInteger32 | read-only | The number of output lines utilized in this device. This variable indicates the number of rows in the output table.(*) |
| upsOutputTable_gen | 1.3.6.1.4.1.818.1.1.10.4.4 | not-accessible | A list of output table entries. The number of entries is given by the value of upsOutputNumLines.(*) | |
| upsOutputEntry_gen | 1.3.6.1.4.1.818.1.1.10.4.4.1 | not-accessible | An entry containing information applicable to a particular output line.(*) | |
| NUM upsOutputLineIndex_gen | 1.3.6.1.4.1.818.1.1.10.4.4.1.1 | PositiveInteger32 | not-accessible | The output line identifier.(*) |
| NUM upsOutputVoltage_gen | 1.3.6.1.4.1.818.1.1.10.4.4.1.2 | NonNegativeInteger32 | read-only | The present output voltage.(*) |
| NUM upsOutputCurrent_gen | 1.3.6.1.4.1.818.1.1.10.4.4.1.3 | NonNegativeInteger32 | read-only | The present output current.(*) |
| NUM upsOutputPower_gen | 1.3.6.1.4.1.818.1.1.10.4.4.1.4 | NonNegativeInteger32 | read-only | The present output true power.(*) |
| I32 upsOutputPercentLoad_gen | 1.3.6.1.4.1.818.1.1.10.4.4.1.5 | Integer32 | read-only | The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.(*) |
| upsBypass_gen | 1.3.6.1.4.1.818.1.1.10.5 | |||
| NUM upsBypassFrequency_gen | 1.3.6.1.4.1.818.1.1.10.5.1 | NonNegativeInteger32 | read-only | The present bypass frequency.(*) |
| NUM upsBypassNumLines_gen | 1.3.6.1.4.1.818.1.1.10.5.2 | NonNegativeInteger32 | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.(*) |
| upsBypassTable_gen | 1.3.6.1.4.1.818.1.1.10.5.3 | not-accessible | A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.(*) | |
| upsBypassEntry_gen | 1.3.6.1.4.1.818.1.1.10.5.3.1 | not-accessible | An entry containing information applicable to a particular bypass input.(*) | |
| NUM upsBypassLineIndex_gen | 1.3.6.1.4.1.818.1.1.10.5.3.1.1 | PositiveInteger32 | not-accessible | The bypass line identifier.(*) |
| NUM upsBypassVoltage_gen | 1.3.6.1.4.1.818.1.1.10.5.3.1.2 | NonNegativeInteger32 | read-only | The present bypass voltage.(*) |
| NUM upsBypassCurrent_gen | 1.3.6.1.4.1.818.1.1.10.5.3.1.3 | NonNegativeInteger32 | read-only | The present bypass current.(*) |
| NUM upsBypassPower_gen | 1.3.6.1.4.1.818.1.1.10.5.3.1.4 | NonNegativeInteger32 | read-only | The present true power conveyed by the bypass.(*) |
| upsAlarm_gen | 1.3.6.1.4.1.818.1.1.10.6 | |||
| G32 upsAlarmsPresent_gen | 1.3.6.1.4.1.818.1.1.10.6.1 | Gauge32 | read-only | The present number of active alarm conditions.(*) |
| upsAlarmTable_gen | 1.3.6.1.4.1.818.1.1.10.6.2 | not-accessible | A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent.(*) | |
| upsAlarmEntry_gen | 1.3.6.1.4.1.818.1.1.10.6.2.1 | not-accessible | An entry containing information applicable to a particular alarm.(*) | |
| NUM upsAlarmId_gen | 1.3.6.1.4.1.818.1.1.10.6.2.1.1 | PositiveInteger32 | not-accessible | A unique identifier for an alarm condition. This value must remain constant.(*) |
| OID upsAlarmDescr_gen | 1.3.6.1.4.1.818.1.1.10.6.2.1.2 | AutonomousType | read-only | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.(*) |
| TIM upsAlarmTime_gen | 1.3.6.1.4.1.818.1.1.10.6.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.(*) |
| upsWellKnownAlarms_gen | 1.3.6.1.4.1.818.1.1.10.6.3 | |||
| upsAlarmBatteryBad_gen | 1.3.6.1.4.1.818.1.1.10.6.3.1 | One or more batteries have been determined to require replacement.(*) | ||
| upsAlarmOnBattery_gen | 1.3.6.1.4.1.818.1.1.10.6.3.2 | The UPS is drawing power from the batteries.(*) | ||
| upsAlarmLowBattery_gen | 1.3.6.1.4.1.818.1.1.10.6.3.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime.(*) | ||
| upsAlarmDepletedBattery_gen | 1.3.6.1.4.1.818.1.1.10.6.3.4 | The UPS will be unable to sustain the present load when and if the utility power is lost.(*) | ||
| upsAlarmTempBad_gen | 1.3.6.1.4.1.818.1.1.10.6.3.5 | A temperature is out of tolerance.(*) | ||
| upsAlarmInputBad_gen | 1.3.6.1.4.1.818.1.1.10.6.3.6 | An input condition is out of tolerance.(*) | ||
| upsAlarmOutputBad_gen | 1.3.6.1.4.1.818.1.1.10.6.3.7 | An output condition (other than OutputOverload) is out of tolerance.(*) | ||
| upsAlarmOutputOverload_gen | 1.3.6.1.4.1.818.1.1.10.6.3.8 | The output load exceeds the UPS output capacity.(*) | ||
| upsAlarmOnBypass_gen | 1.3.6.1.4.1.818.1.1.10.6.3.9 | The Bypass is presently engaged on the UPS.(*) | ||
| upsAlarmBypassBad_gen | 1.3.6.1.4.1.818.1.1.10.6.3.10 | The Bypass is out of tolerance.(*) | ||
| upsAlarmOutputOffAsRequested_gen | 1.3.6.1.4.1.818.1.1.10.6.3.11 | The UPS has shutdown as requested, i.e., the output is off.(*) | ||
| upsAlarmUpsOffAsRequested_gen | 1.3.6.1.4.1.818.1.1.10.6.3.12 | The entire UPS has shutdown as commanded.(*) | ||
| upsAlarmChargerFailed_gen | 1.3.6.1.4.1.818.1.1.10.6.3.13 | An uncorrected problem has been detected within the UPS charger subsystem.(*) | ||
| upsAlarmUpsOutputOff_gen | 1.3.6.1.4.1.818.1.1.10.6.3.14 | The output of the UPS is in the off state.(*) | ||
| upsAlarmUpsSystemOff_gen | 1.3.6.1.4.1.818.1.1.10.6.3.15 | The UPS system is in the off state.(*) | ||
| upsAlarmFanFailure_gen | 1.3.6.1.4.1.818.1.1.10.6.3.16 | The failure of one or more fans in the UPS has been detected.(*) | ||
| upsAlarmFuseFailure_gen | 1.3.6.1.4.1.818.1.1.10.6.3.17 | The failure of one or more fuses has been detected.(*) | ||
| upsAlarmGeneralFault_gen | 1.3.6.1.4.1.818.1.1.10.6.3.18 | A general fault in the UPS has been detected.(*) | ||
| upsAlarmDiagnosticTestFailed_gen | 1.3.6.1.4.1.818.1.1.10.6.3.19 | The result of the last diagnostic test indicates a failure.(*) | ||
| upsAlarmCommunicationsLost_gen | 1.3.6.1.4.1.818.1.1.10.6.3.20 | A problem has been encountered in the communications between the agent and the UPS.(*) | ||
| upsAlarmAwaitingPower_gen | 1.3.6.1.4.1.818.1.1.10.6.3.21 | The UPS output is off and the UPS is awaiting the return of input power.(*) | ||
| upsAlarmShutdownPending_gen | 1.3.6.1.4.1.818.1.1.10.6.3.22 | A upsShutdownAfterDelay countdown is underway.(*) | ||
| upsAlarmShutdownImminent_gen | 1.3.6.1.4.1.818.1.1.10.6.3.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.(*) | ||
| upsAlarmTestInProgress_gen | 1.3.6.1.4.1.818.1.1.10.6.3.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY.(*) | ||
| upsAlarmReceptacleOff_gen | 1.3.6.1.4.1.818.1.1.10.6.3.25 | The receptacle are switch off | ||
| NUM upsAlarmMaskA_gen | 1.3.6.1.4.1.818.1.1.10.6.4 | NonNegativeInteger32 | read-only | Specifies which alarm can be handled by the UPS. The 'Mask' parameter is a Long Integer32. The meaning of every bit is the same as for the 'upsAlarmGroupA' command. A bit having value=1 indicates that the corresponding alarm is handled by the UPS. |
| upsTest_gen | 1.3.6.1.4.1.818.1.1.10.7 | |||
| OID upsTestId_gen | 1.3.6.1.4.1.818.1.1.10.7.1 | OBJECT IDENTIFIER | read-write | The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned.(*) |
| TES upsTestSpinLock_gen | 1.3.6.1.4.1.818.1.1.10.7.2 | TestAndIncr | read-write | A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try-again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock-value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock-value, upsTestId = requested-test) if (error-index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try-again } if (error-index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by polling upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock-value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1.(*) |
| INT upsTestResultsSummary_gen | 1.3.6.1.4.1.818.1.1.10.7.3 | INTEGER | read-only | The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.(*) |
| STR upsTestResultsDetail_gen | 1.3.6.1.4.1.818.1.1.10.7.4 | DisplayString | read-only | Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned.(*) |
| TIM upsTestStartTime_gen | 1.3.6.1.4.1.818.1.1.10.7.5 | TimeStamp | read-only | The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0.(*) |
| NUM upsTestElapsedTime_gen | 1.3.6.1.4.1.818.1.1.10.7.6 | TimeInterval | read-only | The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0.(*) |
| upsWellKnownTests_gen | 1.3.6.1.4.1.818.1.1.10.7.7 | |||
| upsTestNoTestsInitiated_gen | 1.3.6.1.4.1.818.1.1.10.7.7.1 | No tests have been initiated and no test is in progress.(*) | ||
| upsTestAbortTestInProgress_gen | 1.3.6.1.4.1.818.1.1.10.7.7.2 | The test in progress is to be aborted / the test in progress was aborted.(*) | ||
| upsTestGeneralSystemsTest_gen | 1.3.6.1.4.1.818.1.1.10.7.7.3 | The manufacturer's standard test of UPS device systems.(*) | ||
| upsTestQuickBatteryTest_gen | 1.3.6.1.4.1.818.1.1.10.7.7.4 | A test that is sufficient to determine if the battery needs replacement.(*) | ||
| upsTestDeepBatteryCalibration_gen | 1.3.6.1.4.1.818.1.1.10.7.7.5 | The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load.(*) | ||
| upsControl_gen | 1.3.6.1.4.1.818.1.1.10.8 | |||
| INT upsShutdownType_gen | 1.3.6.1.4.1.818.1.1.10.8.1 | INTEGER | read-write | This object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.(*) |
| I32 upsShutdownAfterDelay_gen | 1.3.6.1.4.1.818.1.1.10.8.2 | Integer32 | read-write | Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.(*) |
| I32 upsStartupAfterDelay_gen | 1.3.6.1.4.1.818.1.1.10.8.3 | Integer32 | read-write | Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.(*) |
| I32 upsRebootWithDuration_gen | 1.3.6.1.4.1.818.1.1.10.8.4 | Integer32 | read-write | Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.(*) |
| INT upsAutoRestart_gen | 1.3.6.1.4.1.818.1.1.10.8.5 | INTEGER | read-write | Setting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutdownAfterDelay or an internal battery depleted condition. Setting this object to 'off' will prevent the UPS system from restarting after a shutdown until an operator manually or remotely explicitly restarts it. If the UPS is in a startup or reboot countdown, then the UPS will not restart until that delay has been satisfied.(*) |
| NUM upsReceptaclesNum_gen | 1.3.6.1.4.1.818.1.1.10.8.6 | NonNegativeInteger32 | read-only | The number of receptacles utilized in this device. This entry indicates the number of rows in the receptacle table. |
| upsReceptacleTable_gen | 1.3.6.1.4.1.818.1.1.10.8.7 | not-accessible | A list of receptacle table entries. The number of entries is given by the value of upsReceptacleNum. | |
| upsReceptacleEntry_gen | 1.3.6.1.4.1.818.1.1.10.8.7.1 | not-accessible | An entry containing information applicable to a particular receptacle. | |
| NUM upsReceptacleLineIndex_gen | 1.3.6.1.4.1.818.1.1.10.8.7.1.1 | PositiveInteger32 | not-accessible | The receptacle line identifier. |
| INT upsReceptacleOnOff_gen | 1.3.6.1.4.1.818.1.1.10.8.7.1.2 | INTEGER | read-write | The present state of the receptacle. Setting this object to 'on' will cause the receptacle to be turned on. Setting this object to 'off' will turn the receptacle off. If the receptacle is already in the desired state nothing will happen. After an autorestart (see upsAutoRestart) the receptacle will be on. |
| INT upsUPSMode_gen | 1.3.6.1.4.1.818.1.1.10.8.8 | INTEGER | read-write | The operation mode off the UPS. Off-line indicates a mode in which the input power is transferred to the output directly or via a step-up or step-down transformer. On-line mode indicates a mode in which the output power is regenerated through some convertor. the operating mode of the UPS may be fixed, or may be selectable (e.g. an on-line UPS with ecomode) |
| INT upsRectifierOnOff_gen | 1.3.6.1.4.1.818.1.1.10.8.9 | INTEGER | read-write | The present state of the rectifier. Setting this object to 'on' will cause the rectifier to be turned on. Setting this object to 'off' will turn the rectifier off. If the rectifier is already in the desired state nothing will happen. |
| INT upsBatteryChargeMethod_gen | 1.3.6.1.4.1.818.1.1.10.8.10 | INTEGER | read-write | The present state of the charge method. Setting this object to 'Normal charge' will cause the battery to be charged using the normal method. Setting this object to 'Boost charge' will charge the battery in boost mode. If the charge method is already in the desired state nothing will happen. |
| INT upsInverterOnOff_gen | 1.3.6.1.4.1.818.1.1.10.8.11 | INTEGER | read-write | The present state of the inverter. Setting this object to 'on' will cause the inverter to be turned on. Setting this object to 'off' will turn the inverter off. If the inverter is already in the desired state nothing will happen. |
| INT upsBypassOnOff_gen | 1.3.6.1.4.1.818.1.1.10.8.12 | INTEGER | read-write | The present state of the bypass. Setting this object to 'on' will cause the bypass to be activated. Setting this object to 'off' will deactivate the bypass. If the UPS is already in the desired state nothing will happen. |
| INT upsLoadSource_gen | 1.3.6.1.4.1.818.1.1.10.8.13 | INTEGER | read-write | The present source of the load. Setting this object to 'On bypass' will cause the load to be supplied by the bypass. Setting this object to 'On inverter' will cause the load to be supplied by the inverter. If the load is already supplied by the desired source nothing will happen. |
| upsConfig_gen | 1.3.6.1.4.1.818.1.1.10.9 | |||
| NUM upsConfigInputVoltage_gen | 1.3.6.1.4.1.818.1.1.10.9.1 | NonNegativeInteger32 | read-write | The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigInputFreq_gen | 1.3.6.1.4.1.818.1.1.10.9.2 | NonNegativeInteger32 | read-write | The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVoltage_gen | 1.3.6.1.4.1.818.1.1.10.9.3 | NonNegativeInteger32 | read-write | The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputFreq_gen | 1.3.6.1.4.1.818.1.1.10.9.4 | NonNegativeInteger32 | read-write | The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVA_gen | 1.3.6.1.4.1.818.1.1.10.9.5 | NonNegativeInteger32 | read-only | The magnitude of the nominal Volt-Amp rating.(*) |
| NUM upsConfigOutputPower_gen | 1.3.6.1.4.1.818.1.1.10.9.6 | NonNegativeInteger32 | read-only | The magnitude of the nominal true power rating.(*) |
| NUM upsConfigLowBattTime_gen | 1.3.6.1.4.1.818.1.1.10.9.7 | NonNegativeInteger32 | read-write | The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.(*) |
| INT upsConfigAudibleStatus_gen | 1.3.6.1.4.1.818.1.1.10.9.8 | INTEGER | read-write | The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.(*) |
| NUM upsConfigLowVoltageTransferPoint_gen | 1.3.6.1.4.1.818.1.1.10.9.9 | NonNegativeInteger32 | read-write | The minimum input line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigHighVoltageTransferPoint_gen | 1.3.6.1.4.1.818.1.1.10.9.10 | NonNegativeInteger32 | read-write | The maximum line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigBatteryCapacity_gen | 1.3.6.1.4.1.818.1.1.10.9.11 | NonNegativeInteger32 | read-write | The installed battery capacity. This value is the 'factory'-value, not the value after calibration. |
| NUM upsConfigBatteryChargeCurrent_gen | 1.3.6.1.4.1.818.1.1.10.9.12 | NonNegativeInteger32 | read-write | The maximum battery charge current, including external chargers. |
| INT upsConfigNoLoadShutdown_gen | 1.3.6.1.4.1.818.1.1.10.9.13 | INTEGER | read-write | Dis- or enable 'no load' shutdown from the contact interface. |
| NUM upsConfigStartDelay_gen | 1.3.6.1.4.1.818.1.1.10.9.14 | PositiveInteger32 | read-write | Minimum required autonomy time before the UPS may perform an autorestart. |
| upsGetSet_gen | 1.3.6.1.4.1.818.1.1.10.10 | |||
| NUM upsEventGetNext_gen | 1.3.6.1.4.1.818.1.1.10.10.1 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventSetStartingTimeStamp will be used as the start value of the table with the lowest index number. |
| NUM upsEventGetPrevious_gen | 1.3.6.1.4.1.818.1.1.10.10.2 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventLastTime will be used as the last value of the table with the highest index number. Returns SNMP-NOSUCHNAME for UPSs that don't support this command. |
| NUM upsEventSetStartingTimeStamp_gen | 1.3.6.1.4.1.818.1.1.10.10.3 | NonNegativeInteger32 | read-write | The timestamp which is used as starting point for downloading events from the UPS event buffer |
| NUM upsEventRetreiveCurrentTimeStamp_gen | 1.3.6.1.4.1.818.1.1.10.10.4 | NonNegativeInteger32 | read-only | The current timestamp is retreived from the UPS |
| NUM upsEventTableSize_gen | 1.3.6.1.4.1.818.1.1.10.10.5 | NonNegativeInteger32 | read-only | The number of entries in the event table. This object indicates the number of rows in the event table. |
| upsEventTable_gen | 1.3.6.1.4.1.818.1.1.10.10.6 | not-accessible | A list of event table entries. The number of entries is always 10, and the value of upsEventTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..10)): PDU-SET upsSetStartingTimeStamp PDU-SET upsEventGetNext PDU-GET upsEventTableSize PDU-GET upsEventCode,upsEventStatus,upsEventTime 1 PDU-GET upsEventCode,upsEventStatus,upsEventTime 2 .. PDU-GET upsEventCode,upsEventStatus,upsEventTime The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsEventTableSize. | |
| upsEventEntry_gen | 1.3.6.1.4.1.818.1.1.10.10.6.1 | not-accessible | An entry containing information applicable to a particular event. | |
| NUM upsEventLineIndex_gen | 1.3.6.1.4.1.818.1.1.10.10.6.1.1 | PositiveInteger32 | not-accessible | The event line identifier. |
| NUM upsEventCode_gen | 1.3.6.1.4.1.818.1.1.10.10.6.1.2 | NonNegativeInteger32 | read-only | The event code in numerical format. |
| NUM upsEventStatus_gen | 1.3.6.1.4.1.818.1.1.10.10.6.1.3 | NonNegativeInteger32 | read-only | The status of the UPS at the moment that the event was generated. The format is specified at the 'upsStatus' command. If the UPS is not able to deliver status information, then SNMP-NOSUCHNAME is returned. |
| NUM upsEventTime_gen | 1.3.6.1.4.1.818.1.1.10.10.6.1.4 | NonNegativeInteger32 | read-only | The timestamp of the moment the event was generated. |
| NUM upsParametersRead_gen | 1.3.6.1.4.1.818.1.1.10.10.7 | PositiveInteger32 | read-write | The number of parameters to retreive from the UPS. When this object is set the ParameterTable will be filled with the requested number of entries. The value upsParametersStartAddress will be used as the start value of the table with the lowest index number. |
| NUM upsParametersWrite_gen | 1.3.6.1.4.1.818.1.1.10.10.8 | PositiveInteger32 | read-write | The number of parameters to write to the UPS. When this object is set the ParameterTable will be send to the ups. The value upsParametersStartAddress will be used for the first value of the table with the lowest index number. |
| NUM upsParametersStartAddress_gen | 1.3.6.1.4.1.818.1.1.10.10.9 | NonNegativeInteger32 | read-write | The address which is used as starting point for downloading parameters from the UPS |
| NUM upsParameterTableSize_gen | 1.3.6.1.4.1.818.1.1.10.10.10 | NonNegativeInteger32 | read-only | The number of entries in the parameter table. This object indicates the number of rows in the parameter table. |
| upsParameterTable_gen | 1.3.6.1.4.1.818.1.1.10.10.11 | not-accessible | A list of parameter entries. The number of entries is always 16, and the value of upsParameterTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..16)): Read sequence: PDU-SET upsSetStartingAddress PDU-SET upsParametersRead PDU-GET upsParameterTableSize PDU-GET upsParameterValue 1 PDU-GET upsParameterValue 2 .. PDU-GET upsParameterValue The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsParameterTableSize. Write sequence: PDU-SET upsSetStartingAddress PDU-SET upsParameterValue 1 PDU-SET upsParameterValue 2 .. PDU-SET upsParameterValue PDU-SET upsParametersWrite | |
| upsParameterEntry_gen | 1.3.6.1.4.1.818.1.1.10.10.11.1 | not-accessible | An entry containing information applicable to a particular parameter. | |
| NUM upsParameterLineIndex_gen | 1.3.6.1.4.1.818.1.1.10.10.11.1.1 | PositiveInteger32 | not-accessible | The parameter line identifier. |
| I32 upsParameterValue_gen | 1.3.6.1.4.1.818.1.1.10.10.11.1.2 | Integer32 | read-write | The parameter value in numerical format. |
| NUM upsStatus_gen | 1.3.6.1.4.1.818.1.1.10.10.12 | NonNegativeInteger32 | read-only | The global UPS status is returned. Every bit reflects a specific status condition. Unused bits returns as 0. The status value can also be found on other commands. The value SNMP-NOSUCHNAME means 'invalid status' or 'status value non available'. Status 1 0001h upsStatusEcomodeIsOn 2 0002h upsStatusBatteryIsCharging 4 0004h upsStatusBatteryIsDischarging 8 0008h upsStatusAlarmIsActive 16 0010h upsStatusRectifierIsOn 32 0020h upsStatusLowBattery 64 0040h upsStatusOnBypass 128 0080h upsStatusMainsBypassOK 256 0100h upsStatusMainsRectifierOK 512 0200h upsStatusDetourIsOn 1024 0400h upsStatusAcousticAlarmIsOn 2048 0800h - (not used.) 4096 1000h upsStatusInverterIsOn 8192 2000h upsStatusNotInParallel (Q1 open) 16384 4000h upsStatusResetLoadOff 32768 8000h upsStatusLoadOff |
| NUM upsMainsStatisticsMBfail_gen | 1.3.6.1.4.1.818.1.1.10.10.13 | NonNegativeInteger32 | read-only | Count of main bypass failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsMRfail_gen | 1.3.6.1.4.1.818.1.1.10.10.14 | NonNegativeInteger32 | read-only | Count of mains rectifier failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsB2_gen | 1.3.6.1.4.1.818.1.1.10.10.15 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (0..2 ms), during the last 7 days. |
| NUM upsMainsStatisticsB5_gen | 1.3.6.1.4.1.818.1.1.10.10.16 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (2..5 ms), during the last 7 days. |
| NUM upsMainsStatisticsB10_gen | 1.3.6.1.4.1.818.1.1.10.10.17 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (5..10 ms), during the last 7 days. |
| NUM upsMainsStatisticsB200_gen | 1.3.6.1.4.1.818.1.1.10.10.18 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (10..200 ms), during the last 7 days. |
| NUM upsMainsStatisticsBypRel_gen | 1.3.6.1.4.1.818.1.1.10.10.19 | NonNegativeInteger32 | read-only | Bypass reliability degree [0..100%;255]. The value NOSUCHNAME means 'not available'. |
| NUM upsTime_gen | 1.3.6.1.4.1.818.1.1.10.10.20 | NonNegativeInteger32 | read-write | The current timestamp (or real-time) of the UPS. For the format, see 'Timestamp' specifications. The write-command has to comply with the correct timestamp format expected by the UPS (counter value or real-time-clock value). Missing to doing so will result in a SNMP-genERROR, meaning 'command not supported'. It is possible to know which is the timestamp format supported by the UPS, by issuing a read-command or by reading events, which includes timestamps. |
| STR upsRequestPermission_gen | 1.3.6.1.4.1.818.1.1.10.10.21 | DisplayString | write-only | An encrypted code is send to enable use of restricted write objects during a limited period of time. |
| I32 upsEventGetCode_gen | 1.3.6.1.4.1.818.1.1.10.10.22 | Integer32 | write-only | The code which is used as starting point to downloading the events from the UPS event buffer. |
| TES upsEventSpinLock_gen | 1.3.6.1.4.1.818.1.1.10.10.23 | TestAndIncr | read-write | A spin lock on the event subsystem. |
| TES upsParameterSpinLock_gen | 1.3.6.1.4.1.818.1.1.10.10.24 | TestAndIncr | read-write | A spin lock on the parameters subsystem. |
| geUPSTraps_gen | 1.3.6.1.4.1.818.1.1.10.11 | |||
| NTF upsAlarmBatteryBadTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.1 | One or more batteries have been determined to require replacement. | ||
| NTF upsAlarmOnBatteryTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.2 | An On Battery condition is restored. | ||
| NTF upsAlarmLowBatteryTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime. | ||
| NTF upsAlarmDepletedBatteryTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.4 | The UPS will be unable to sustain the present load when and if the utility power is lost) | ||
| NTF upsAlarmTempBadTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.5 | A temperature is out of tolerance. | ||
| NTF upsAlarmInputBadTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.6 | An input condition is out of tolerance. | ||
| NTF upsAlarmOutputBadTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.7 | An output condition (other than OutputOverload) is out of tolerance. | ||
| NTF upsAlarmOutputOverloadTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.8 | The output load exceeds the UPS output capacity. | ||
| NTF upsAlarmOnBypassTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.9 | The Bypass is presently engaged on the UPS. | ||
| NTF upsAlarmBypassBadTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.10 | The Bypass is out of tolerance. | ||
| NTF upsAlarmOutputOffAsRequestedTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.11 | The UPS has shutdown as requested, i.e., the output is off. | ||
| NTF upsAlarmUpsOffAsRequestedTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.12 | The entire UPS has shutdown as commanded. | ||
| NTF upsAlarmChargerFailedTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.13 | An uncorrected problem has been detected within the UPS charger subsystem. | ||
| NTF upsAlarmUpsOutputOffTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.14 | The output of the UPS is in the off state. | ||
| NTF upsAlarmUpsSystemOffTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.15 | The UPS system is in the off state. | ||
| NTF upsAlarmFanFailureTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.16 | The failure of one or more fans in the UPS has been detected. | ||
| NTF upsAlarmFuseFailureTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.17 | The failure of one or more fuses has been detected. | ||
| NTF upsAlarmGeneralFaultTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.18 | A general fault in the UPS has been detected. | ||
| NTF upsAlarmDiagnosticTestFailedTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.19 | The result of the last diagnostic test indicates a failure. | ||
| NTF upsAlarmCommunicationsLostTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.20 | A problem has been encountered in the communication between the agent and the UPS. | ||
| NTF upsAlarmAwaitingPowerTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.21 | The UPS output is off and the UPS is awaiting the return of the input power (*). | ||
| NTF upsAlarmShutdownPendingTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.22 | A upsShutdownAfterDelay countdown is underway. | ||
| NTF upsAlarmShutdownImminentTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | ||
| NTF upsAlarmTestInProgressTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | ||
| NTF upsAlarmReceptacleOffTrap_gen | 1.3.6.1.4.1.818.1.1.10.11.0.25 | A receptacle has been switched off. | ||
| NTF upsAlarmBatteryBadRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.33 | A Battery bad condition is restored. | ||
| NTF upsAlarmOnBatteryRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.34 | The UPS is drawing power from mains again. | ||
| NTF upsAlarmLowBatteryRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.35 | A Low Battery condition is restored. | ||
| NTF upsAlarmDepletedBatteryRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.36 | A Depleted Battery condition is restored. | ||
| NTF upsAlarmTempBadRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.37 | A bad temperature condition is restored. | ||
| NTF upsAlarmInputBadRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.38 | An input bad condition is restored. | ||
| NTF upsAlarmOutputBadRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.39 | An output bad condition is restored. | ||
| NTF upsAlarmOutputOverloadRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.40 | An output overload condition is restored. | ||
| NTF upsAlarmOnBypassRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.41 | An On Bypass condition is restored. | ||
| NTF upsAlarmBypassBadRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.42 | A Bypass bad condition is restored. | ||
| NTF upsAlarmOutputOffAsRequestedRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.43 | A request shutdown has been restored. | ||
| NTF upsAlarmUpsOffAsRequestedRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.44 | A entire UPS command has been restored. | ||
| NTF upsAlarmChargerFailedRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.45 | A Charger Failer condition is restored. | ||
| NTF upsAlarmUpsOutputOn_gen | 1.3.6.1.4.1.818.1.1.10.11.0.46 | The output of the UPS switched in the on state. | ||
| NTF upsAlarmUpsSystemOn_gen | 1.3.6.1.4.1.818.1.1.10.11.0.47 | The UPS system is switched in the on state. | ||
| NTF upsAlarmFanFailureRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.48 | A Fan failure condition is restored. | ||
| NTF upsAlarmFuseFailureRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.49 | A Fuse failure condition is restored. | ||
| NTF upsAlarmGeneralFaultRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.50 | A general fault is restored. | ||
| NTF upsAlarmDiagnosticTestFailedRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.51 | A last diagnostic test indicates a failure is restored. | ||
| NTF upsAlarmCommunicationsLostRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.52 | A problem in the communication between the agent and the UPS is restored. | ||
| NTF upsAlarmAwaitingPowerRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.53 | A awaiting power condition is restored (*). | ||
| NTF upsAlarmShutdownPendingRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.54 | A upsShutdownAfterDelay countdown is restored. | ||
| NTF upsAlarmShutdownImminentRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.55 | A shutdown imminent condition is restored. | ||
| NTF upsAlarmTestInProgressRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.56 | The test is in progress is terminated. | ||
| NTF upsAlarmReceptacleOn_gen | 1.3.6.1.4.1.818.1.1.10.11.0.57 | A receptacle has been switched on. | ||
| NTF upsAlarmValueLow_gen | 1.3.6.1.4.1.818.1.1.10.11.0.129 | A measurement value reached a value below its low-level threshold. | ||
| NTF upsAlarmValueHigh_gen | 1.3.6.1.4.1.818.1.1.10.11.0.130 | A measurement value reached a value higher than its high-level threshold. | ||
| NTF upsAlarmValueLowRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.133 | A ValueLow alarm condition is restored. | ||
| NTF upsAlarmValueHighRestored_gen | 1.3.6.1.4.1.818.1.1.10.11.0.134 | A ValueHigh alarm condition is restored. | ||
| geFirstUPS | 1.3.6.1.4.1.818.1.1.11 | |||
| upsIdent_first | 1.3.6.1.4.1.818.1.1.11.1 | |||
| STR upsIdentManufacturer_first | 1.3.6.1.4.1.818.1.1.11.1.1 | DisplayString | read-only | The name of the UPS manufacturer.(*) |
| STR upsIdentModel_first | 1.3.6.1.4.1.818.1.1.11.1.2 | DisplayString | read-only | The UPS Model designation.(*) |
| STR upsIdentUPSSoftwareVersion_first | 1.3.6.1.4.1.818.1.1.11.1.3 | DisplayString | read-only | The UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.(*) |
| STR upsIdentAgentSoftwareVersion_first | 1.3.6.1.4.1.818.1.1.11.1.4 | DisplayString | read-only | The UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.(*) |
| STR upsIdentName_first | 1.3.6.1.4.1.818.1.1.11.1.5 | DisplayString | read-write | A string identifying the UPS. This object should be set by the administrator.(*) |
| STR upsIdentAttachedDevices_first | 1.3.6.1.4.1.818.1.1.11.1.6 | DisplayString | read-write | A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.(*) |
| STR upsIdentUPSSerialNumber_first | 1.3.6.1.4.1.818.1.1.11.1.7 | DisplayString | read-only | The UPS serial number |
| STR upsIdentComProtVersion_first | 1.3.6.1.4.1.818.1.1.11.1.8 | DisplayString | read-only | The IMV communication protocol version |
| NUM upsIdentOperatingTime_first | 1.3.6.1.4.1.818.1.1.11.1.9 | NonNegativeInteger32 | read-only | The present value of the operating time. total 'on' time since UPS manufactured |
| upsBattery_first | 1.3.6.1.4.1.818.1.1.11.2 | |||
| INT upsBatteryStatus_first | 1.3.6.1.4.1.818.1.1.11.2.1 | INTEGER | read-only | The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).(*) |
| NUM upsSecondsOnBattery_first | 1.3.6.1.4.1.818.1.1.11.2.2 | NonNegativeInteger32 | read-only | If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.(*) |
| NUM upsEstimatedMinutesRemaining_first | 1.3.6.1.4.1.818.1.1.11.2.3 | PositiveInteger32 | read-only | An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.(*) |
| I32 upsEstimatedChargeRemaining_first | 1.3.6.1.4.1.818.1.1.11.2.4 | Integer32 | read-only | An estimate of the battery charge remaining expressed as a percent of full charge.(*) |
| NUM upsBatteryVoltage_first | 1.3.6.1.4.1.818.1.1.11.2.5 | NonNegativeInteger32 | read-only | The magnitude of the present battery voltage.(*) |
| I32 upsBatteryCurrent_first | 1.3.6.1.4.1.818.1.1.11.2.6 | Integer32 | read-only | The present battery current.(*) |
| I32 upsBatteryTemperature_first | 1.3.6.1.4.1.818.1.1.11.2.7 | Integer32 | read-only | The ambient temperature at or near the UPS Battery casing.(*) |
| upsInput_first | 1.3.6.1.4.1.818.1.1.11.3 | |||
| C32 upsInputLineBads_first | 1.3.6.1.4.1.818.1.1.11.3.1 | Counter32 | read-only | A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.(*) |
| NUM upsInputNumLines_first | 1.3.6.1.4.1.818.1.1.11.3.2 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This variable indicates the number of rows in the input table.(*) |
| upsInputTable_first | 1.3.6.1.4.1.818.1.1.11.3.3 | not-accessible | A list of input table entries. The number of entries is given by the value of upsInputNumLines.(*) | |
| upsInputEntry_first | 1.3.6.1.4.1.818.1.1.11.3.3.1 | not-accessible | An entry containing information applicable to a particular input line.(*) | |
| NUM upsInputLineIndex_first | 1.3.6.1.4.1.818.1.1.11.3.3.1.1 | PositiveInteger32 | not-accessible | The input line identifier.(*) |
| NUM upsInputFrequency_first | 1.3.6.1.4.1.818.1.1.11.3.3.1.2 | NonNegativeInteger32 | read-only | The present input frequency.(*) |
| NUM upsInputVoltage_first | 1.3.6.1.4.1.818.1.1.11.3.3.1.3 | NonNegativeInteger32 | read-only | The magnitude of the present input voltage.(*) |
| NUM upsInputCurrent_first | 1.3.6.1.4.1.818.1.1.11.3.3.1.4 | NonNegativeInteger32 | read-only | The magnitude of the present input current.(*) |
| NUM upsInputTruePower_first | 1.3.6.1.4.1.818.1.1.11.3.3.1.5 | NonNegativeInteger32 | read-only | The magnitude of the present input true power.(*) |
| NUM upsInputVoltageMin_first | 1.3.6.1.4.1.818.1.1.11.3.3.1.6 | NonNegativeInteger32 | read-only | The lowest magnitude of the input voltage since last read out. |
| NUM upsInputVoltageMax_first | 1.3.6.1.4.1.818.1.1.11.3.3.1.7 | NonNegativeInteger32 | read-only | The highest magnitude of the input voltage since last read out. |
| upsOutput_first | 1.3.6.1.4.1.818.1.1.11.4 | |||
| INT upsOutputSource_first | 1.3.6.1.4.1.818.1.1.11.4.1 | INTEGER | read-only | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.(*) |
| NUM upsOutputFrequency_first | 1.3.6.1.4.1.818.1.1.11.4.2 | NonNegativeInteger32 | read-only | The present output frequency.(*) |
| NUM upsOutputNumLines_first | 1.3.6.1.4.1.818.1.1.11.4.3 | NonNegativeInteger32 | read-only | The number of output lines utilized in this device. This variable indicates the number of rows in the output table.(*) |
| upsOutputTable_first | 1.3.6.1.4.1.818.1.1.11.4.4 | not-accessible | A list of output table entries. The number of entries is given by the value of upsOutputNumLines.(*) | |
| upsOutputEntry_first | 1.3.6.1.4.1.818.1.1.11.4.4.1 | not-accessible | An entry containing information applicable to a particular output line.(*) | |
| NUM upsOutputLineIndex_first | 1.3.6.1.4.1.818.1.1.11.4.4.1.1 | PositiveInteger32 | not-accessible | The output line identifier.(*) |
| NUM upsOutputVoltage_first | 1.3.6.1.4.1.818.1.1.11.4.4.1.2 | NonNegativeInteger32 | read-only | The present output voltage.(*) |
| NUM upsOutputCurrent_first | 1.3.6.1.4.1.818.1.1.11.4.4.1.3 | NonNegativeInteger32 | read-only | The present output current.(*) |
| NUM upsOutputPower_first | 1.3.6.1.4.1.818.1.1.11.4.4.1.4 | NonNegativeInteger32 | read-only | The present output true power.(*) |
| I32 upsOutputPercentLoad_first | 1.3.6.1.4.1.818.1.1.11.4.4.1.5 | Integer32 | read-only | The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.(*) |
| upsBypass_first | 1.3.6.1.4.1.818.1.1.11.5 | |||
| NUM upsBypassFrequency_first | 1.3.6.1.4.1.818.1.1.11.5.1 | NonNegativeInteger32 | read-only | The present bypass frequency.(*) |
| NUM upsBypassNumLines_first | 1.3.6.1.4.1.818.1.1.11.5.2 | NonNegativeInteger32 | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.(*) |
| upsBypassTable_first | 1.3.6.1.4.1.818.1.1.11.5.3 | not-accessible | A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.(*) | |
| upsBypassEntry_first | 1.3.6.1.4.1.818.1.1.11.5.3.1 | not-accessible | An entry containing information applicable to a particular bypass input.(*) | |
| NUM upsBypassLineIndex_first | 1.3.6.1.4.1.818.1.1.11.5.3.1.1 | PositiveInteger32 | not-accessible | The bypass line identifier.(*) |
| NUM upsBypassVoltage_first | 1.3.6.1.4.1.818.1.1.11.5.3.1.2 | NonNegativeInteger32 | read-only | The present bypass voltage.(*) |
| NUM upsBypassCurrent_first | 1.3.6.1.4.1.818.1.1.11.5.3.1.3 | NonNegativeInteger32 | read-only | The present bypass current.(*) |
| NUM upsBypassPower_first | 1.3.6.1.4.1.818.1.1.11.5.3.1.4 | NonNegativeInteger32 | read-only | The present true power conveyed by the bypass.(*) |
| upsAlarm_first | 1.3.6.1.4.1.818.1.1.11.6 | |||
| G32 upsAlarmsPresent_first | 1.3.6.1.4.1.818.1.1.11.6.1 | Gauge32 | read-only | The present number of active alarm conditions.(*) |
| upsAlarmTable_first | 1.3.6.1.4.1.818.1.1.11.6.2 | not-accessible | A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent.(*) | |
| upsAlarmEntry_first | 1.3.6.1.4.1.818.1.1.11.6.2.1 | not-accessible | An entry containing information applicable to a particular alarm.(*) | |
| NUM upsAlarmId_first | 1.3.6.1.4.1.818.1.1.11.6.2.1.1 | PositiveInteger32 | not-accessible | A unique identifier for an alarm condition. This value must remain constant.(*) |
| OID upsAlarmDescr_first | 1.3.6.1.4.1.818.1.1.11.6.2.1.2 | AutonomousType | read-only | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.(*) |
| TIM upsAlarmTime_first | 1.3.6.1.4.1.818.1.1.11.6.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.(*) |
| upsWellKnownAlarms_first | 1.3.6.1.4.1.818.1.1.11.6.3 | |||
| upsAlarmBatteryBad_first | 1.3.6.1.4.1.818.1.1.11.6.3.1 | One or more batteries have been determined to require replacement.(*) | ||
| upsAlarmOnBattery_first | 1.3.6.1.4.1.818.1.1.11.6.3.2 | The UPS is drawing power from the batteries.(*) | ||
| upsAlarmLowBattery_first | 1.3.6.1.4.1.818.1.1.11.6.3.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime.(*) | ||
| upsAlarmDepletedBattery_first | 1.3.6.1.4.1.818.1.1.11.6.3.4 | The UPS will be unable to sustain the present load when and if the utility power is lost.(*) | ||
| upsAlarmTempBad_first | 1.3.6.1.4.1.818.1.1.11.6.3.5 | A temperature is out of tolerance.(*) | ||
| upsAlarmInputBad_first | 1.3.6.1.4.1.818.1.1.11.6.3.6 | An input condition is out of tolerance.(*) | ||
| upsAlarmOutputBad_first | 1.3.6.1.4.1.818.1.1.11.6.3.7 | An output condition (other than OutputOverload) is out of tolerance.(*) | ||
| upsAlarmOutputOverload_first | 1.3.6.1.4.1.818.1.1.11.6.3.8 | The output load exceeds the UPS output capacity.(*) | ||
| upsAlarmOnBypass_first | 1.3.6.1.4.1.818.1.1.11.6.3.9 | The Bypass is presently engaged on the UPS.(*) | ||
| upsAlarmBypassBad_first | 1.3.6.1.4.1.818.1.1.11.6.3.10 | The Bypass is out of tolerance.(*) | ||
| upsAlarmOutputOffAsRequested_first | 1.3.6.1.4.1.818.1.1.11.6.3.11 | The UPS has shutdown as requested, i.e., the output is off.(*) | ||
| upsAlarmUpsOffAsRequested_first | 1.3.6.1.4.1.818.1.1.11.6.3.12 | The entire UPS has shutdown as commanded.(*) | ||
| upsAlarmChargerFailed_first | 1.3.6.1.4.1.818.1.1.11.6.3.13 | An uncorrected problem has been detected within the UPS charger subsystem.(*) | ||
| upsAlarmUpsOutputOff_first | 1.3.6.1.4.1.818.1.1.11.6.3.14 | The output of the UPS is in the off state.(*) | ||
| upsAlarmUpsSystemOff_first | 1.3.6.1.4.1.818.1.1.11.6.3.15 | The UPS system is in the off state.(*) | ||
| upsAlarmFanFailure_first | 1.3.6.1.4.1.818.1.1.11.6.3.16 | The failure of one or more fans in the UPS has been detected.(*) | ||
| upsAlarmFuseFailure_first | 1.3.6.1.4.1.818.1.1.11.6.3.17 | The failure of one or more fuses has been detected.(*) | ||
| upsAlarmGeneralFault_first | 1.3.6.1.4.1.818.1.1.11.6.3.18 | A general fault in the UPS has been detected.(*) | ||
| upsAlarmDiagnosticTestFailed_first | 1.3.6.1.4.1.818.1.1.11.6.3.19 | The result of the last diagnostic test indicates a failure.(*) | ||
| upsAlarmCommunicationsLost_first | 1.3.6.1.4.1.818.1.1.11.6.3.20 | A problem has been encountered in the communications between the agent and the UPS.(*) | ||
| upsAlarmAwaitingPower_first | 1.3.6.1.4.1.818.1.1.11.6.3.21 | The UPS output is off and the UPS is awaiting the return of input power.(*) | ||
| upsAlarmShutdownPending_first | 1.3.6.1.4.1.818.1.1.11.6.3.22 | A upsShutdownAfterDelay countdown is underway.(*) | ||
| upsAlarmShutdownImminent_first | 1.3.6.1.4.1.818.1.1.11.6.3.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.(*) | ||
| upsAlarmTestInProgress_first | 1.3.6.1.4.1.818.1.1.11.6.3.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY.(*) | ||
| upsAlarmReceptacleOff_first | 1.3.6.1.4.1.818.1.1.11.6.3.25 | The receptacle are switch off | ||
| NUM upsAlarmMaskA_first | 1.3.6.1.4.1.818.1.1.11.6.4 | NonNegativeInteger32 | read-only | Specifies which alarm can be handled by the UPS. The 'Mask' parameter is a Long Integer32. The meaning of every bit is the same as for the 'upsAlarmGroupA' command. A bit having value=1 indicates that the corresponding alarm is handled by the UPS. |
| upsTest_first | 1.3.6.1.4.1.818.1.1.11.7 | |||
| OID upsTestId_first | 1.3.6.1.4.1.818.1.1.11.7.1 | OBJECT IDENTIFIER | read-write | The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned.(*) |
| TES upsTestSpinLock_first | 1.3.6.1.4.1.818.1.1.11.7.2 | TestAndIncr | read-write | A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try-again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock-value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock-value, upsTestId = requested-test) if (error-index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try-again } if (error-index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by polling upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock-value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1.(*) |
| INT upsTestResultsSummary_first | 1.3.6.1.4.1.818.1.1.11.7.3 | INTEGER | read-only | The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.(*) |
| STR upsTestResultsDetail_first | 1.3.6.1.4.1.818.1.1.11.7.4 | DisplayString | read-only | Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned.(*) |
| TIM upsTestStartTime_first | 1.3.6.1.4.1.818.1.1.11.7.5 | TimeStamp | read-only | The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0.(*) |
| NUM upsTestElapsedTime_first | 1.3.6.1.4.1.818.1.1.11.7.6 | TimeInterval | read-only | The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0.(*) |
| upsWellKnownTests_first | 1.3.6.1.4.1.818.1.1.11.7.7 | |||
| upsTestNoTestsInitiated_first | 1.3.6.1.4.1.818.1.1.11.7.7.1 | No tests have been initiated and no test is in progress.(*) | ||
| upsTestAbortTestInProgress_first | 1.3.6.1.4.1.818.1.1.11.7.7.2 | The test in progress is to be aborted / the test in progress was aborted.(*) | ||
| upsTestGeneralSystemsTest_first | 1.3.6.1.4.1.818.1.1.11.7.7.3 | The manufacturer's standard test of UPS device systems.(*) | ||
| upsTestQuickBatteryTest_first | 1.3.6.1.4.1.818.1.1.11.7.7.4 | A test that is sufficient to determine if the battery needs replacement.(*) | ||
| upsTestDeepBatteryCalibration_first | 1.3.6.1.4.1.818.1.1.11.7.7.5 | The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load.(*) | ||
| upsControl_first | 1.3.6.1.4.1.818.1.1.11.8 | |||
| INT upsShutdownType_first | 1.3.6.1.4.1.818.1.1.11.8.1 | INTEGER | read-write | This object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.(*) |
| I32 upsShutdownAfterDelay_first | 1.3.6.1.4.1.818.1.1.11.8.2 | Integer32 | read-write | Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.(*) |
| I32 upsStartupAfterDelay_first | 1.3.6.1.4.1.818.1.1.11.8.3 | Integer32 | read-write | Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.(*) |
| I32 upsRebootWithDuration_first | 1.3.6.1.4.1.818.1.1.11.8.4 | Integer32 | read-write | Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.(*) |
| INT upsAutoRestart_first | 1.3.6.1.4.1.818.1.1.11.8.5 | INTEGER | read-write | Setting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutdownAfterDelay or an internal battery depleted condition. Setting this object to 'off' will prevent the UPS system from restarting after a shutdown until an operator manually or remotely explicitly restarts it. If the UPS is in a startup or reboot countdown, then the UPS will not restart until that delay has been satisfied.(*) |
| NUM upsReceptaclesNum_first | 1.3.6.1.4.1.818.1.1.11.8.6 | NonNegativeInteger32 | read-only | The number of receptacles utilized in this device. This entry indicates the number of rows in the receptacle table. |
| upsReceptacleTable_first | 1.3.6.1.4.1.818.1.1.11.8.7 | not-accessible | A list of receptacle table entries. The number of entries is given by the value of upsReceptacleNum. | |
| upsReceptacleEntry_first | 1.3.6.1.4.1.818.1.1.11.8.7.1 | not-accessible | An entry containing information applicable to a particular receptacle. | |
| NUM upsReceptacleLineIndex_first | 1.3.6.1.4.1.818.1.1.11.8.7.1.1 | PositiveInteger32 | not-accessible | The receptacle line identifier. |
| INT upsReceptacleOnOff_first | 1.3.6.1.4.1.818.1.1.11.8.7.1.2 | INTEGER | read-write | The present state of the receptacle. Setting this object to 'on' will cause the receptacle to be turned on. Setting this object to 'off' will turn the receptacle off. If the receptacle is already in the desired state nothing will happen. After an autorestart (see upsAutoRestart) the receptacle will be on. |
| INT upsUPSMode_first | 1.3.6.1.4.1.818.1.1.11.8.8 | INTEGER | read-write | The operation mode off the UPS. Off-line indicates a mode in which the input power is transferred to the output directly or via a step-up or step-down transformer. On-line mode indicates a mode in which the output power is regenerated through some convertor. the operating mode of the UPS may be fixed, or may be selectable (e.g. an on-line UPS with ecomode) |
| INT upsRectifierOnOff_first | 1.3.6.1.4.1.818.1.1.11.8.9 | INTEGER | read-write | The present state of the rectifier. Setting this object to 'on' will cause the rectifier to be turned on. Setting this object to 'off' will turn the rectifier off. If the rectifier is already in the desired state nothing will happen. |
| INT upsBatteryChargeMethod_first | 1.3.6.1.4.1.818.1.1.11.8.10 | INTEGER | read-write | The present state of the charge method. Setting this object to 'Normal charge' will cause the battery to be charged using the normal method. Setting this object to 'Boost charge' will charge the battery in boost mode. If the charge method is already in the desired state nothing will happen. |
| INT upsInverterOnOff_first | 1.3.6.1.4.1.818.1.1.11.8.11 | INTEGER | read-write | The present state of the inverter. Setting this object to 'on' will cause the inverter to be turned on. Setting this object to 'off' will turn the inverter off. If the inverter is already in the desired state nothing will happen. |
| INT upsBypassOnOff_first | 1.3.6.1.4.1.818.1.1.11.8.12 | INTEGER | read-write | The present state of the bypass. Setting this object to 'on' will cause the bypass to be activated. Setting this object to 'off' will deactivate the bypass. If the UPS is already in the desired state nothing will happen. |
| INT upsLoadSource_first | 1.3.6.1.4.1.818.1.1.11.8.13 | INTEGER | read-write | The present source of the load. Setting this object to 'On bypass' will cause the load to be supplied by the bypass. Setting this object to 'On inverter' will cause the load to be supplied by the inverter. If the load is already supplied by the desired source nothing will happen. |
| upsConfig_first | 1.3.6.1.4.1.818.1.1.11.9 | |||
| NUM upsConfigInputVoltage_first | 1.3.6.1.4.1.818.1.1.11.9.1 | NonNegativeInteger32 | read-write | The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigInputFreq_first | 1.3.6.1.4.1.818.1.1.11.9.2 | NonNegativeInteger32 | read-write | The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVoltage_first | 1.3.6.1.4.1.818.1.1.11.9.3 | NonNegativeInteger32 | read-write | The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputFreq_first | 1.3.6.1.4.1.818.1.1.11.9.4 | NonNegativeInteger32 | read-write | The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVA_first | 1.3.6.1.4.1.818.1.1.11.9.5 | NonNegativeInteger32 | read-only | The magnitude of the nominal Volt-Amp rating.(*) |
| NUM upsConfigOutputPower_first | 1.3.6.1.4.1.818.1.1.11.9.6 | NonNegativeInteger32 | read-only | The magnitude of the nominal true power rating.(*) |
| NUM upsConfigLowBattTime_first | 1.3.6.1.4.1.818.1.1.11.9.7 | NonNegativeInteger32 | read-write | The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.(*) |
| INT upsConfigAudibleStatus_first | 1.3.6.1.4.1.818.1.1.11.9.8 | INTEGER | read-write | The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.(*) |
| NUM upsConfigLowVoltageTransferPoint_first | 1.3.6.1.4.1.818.1.1.11.9.9 | NonNegativeInteger32 | read-write | The minimum input line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigHighVoltageTransferPoint_first | 1.3.6.1.4.1.818.1.1.11.9.10 | NonNegativeInteger32 | read-write | The maximum line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigBatteryCapacity_first | 1.3.6.1.4.1.818.1.1.11.9.11 | NonNegativeInteger32 | read-write | The installed battery capacity. This value is the 'factory'-value, not the value after calibration. |
| NUM upsConfigBatteryChargeCurrent_first | 1.3.6.1.4.1.818.1.1.11.9.12 | NonNegativeInteger32 | read-write | The maximum battery charge current, including external chargers. |
| INT upsConfigNoLoadShutdown_first | 1.3.6.1.4.1.818.1.1.11.9.13 | INTEGER | read-write | Dis- or enable 'no load' shutdown from the contact interface. |
| NUM upsConfigStartDelay_first | 1.3.6.1.4.1.818.1.1.11.9.14 | PositiveInteger32 | read-write | Minimum required autonomy time before the UPS may perform an autorestart. |
| upsGetSet_first | 1.3.6.1.4.1.818.1.1.11.10 | |||
| NUM upsEventGetNext_first | 1.3.6.1.4.1.818.1.1.11.10.1 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventSetStartingTimeStamp will be used as the start value of the table with the lowest index number. |
| NUM upsEventGetPrevious_first | 1.3.6.1.4.1.818.1.1.11.10.2 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventLastTime will be used as the last value of the table with the highest index number. Returns SNMP-NOSUCHNAME for UPSs that don't support this command. |
| NUM upsEventSetStartingTimeStamp_first | 1.3.6.1.4.1.818.1.1.11.10.3 | NonNegativeInteger32 | read-write | The timestamp which is used as starting point for downloading events from the UPS event buffer |
| NUM upsEventRetreiveCurrentTimeStamp_first | 1.3.6.1.4.1.818.1.1.11.10.4 | NonNegativeInteger32 | read-only | The current timestamp is retreived from the UPS |
| NUM upsEventTableSize_first | 1.3.6.1.4.1.818.1.1.11.10.5 | NonNegativeInteger32 | read-only | The number of entries in the event table. This object indicates the number of rows in the event table. |
| upsEventTable_first | 1.3.6.1.4.1.818.1.1.11.10.6 | not-accessible | A list of event table entries. The number of entries is always 10, and the value of upsEventTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..10)): PDU-SET upsSetStartingTimeStamp PDU-SET upsEventGetNext PDU-GET upsEventTableSize PDU-GET upsEventCode,upsEventStatus,upsEventTime 1 PDU-GET upsEventCode,upsEventStatus,upsEventTime 2 .. PDU-GET upsEventCode,upsEventStatus,upsEventTime The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsEventTableSize. | |
| upsEventEntry_first | 1.3.6.1.4.1.818.1.1.11.10.6.1 | not-accessible | An entry containing information applicable to a particular event. | |
| NUM upsEventLineIndex_first | 1.3.6.1.4.1.818.1.1.11.10.6.1.1 | PositiveInteger32 | not-accessible | The event line identifier. |
| NUM upsEventCode_first | 1.3.6.1.4.1.818.1.1.11.10.6.1.2 | NonNegativeInteger32 | read-only | The event code in numerical format. |
| NUM upsEventStatus_first | 1.3.6.1.4.1.818.1.1.11.10.6.1.3 | NonNegativeInteger32 | read-only | The status of the UPS at the moment that the event was generated. The format is specified at the 'upsStatus' command. If the UPS is not able to deliver status information, then SNMP-NOSUCHNAME is returned. |
| NUM upsEventTime_first | 1.3.6.1.4.1.818.1.1.11.10.6.1.4 | NonNegativeInteger32 | read-only | The timestamp of the moment the event was generated. |
| NUM upsParametersRead_first | 1.3.6.1.4.1.818.1.1.11.10.7 | PositiveInteger32 | read-write | The number of parameters to retreive from the UPS. When this object is set the ParameterTable will be filled with the requested number of entries. The value upsParametersStartAddress will be used as the start value of the table with the lowest index number. |
| NUM upsParametersWrite_first | 1.3.6.1.4.1.818.1.1.11.10.8 | PositiveInteger32 | read-write | The number of parameters to write to the UPS. When this object is set the ParameterTable will be send to the ups. The value upsParametersStartAddress will be used for the first value of the table with the lowest index number. |
| NUM upsParametersStartAddress_first | 1.3.6.1.4.1.818.1.1.11.10.9 | NonNegativeInteger32 | read-write | The address which is used as starting point for downloading parameters from the UPS |
| NUM upsParameterTableSize_first | 1.3.6.1.4.1.818.1.1.11.10.10 | NonNegativeInteger32 | read-only | The number of entries in the parameter table. This object indicates the number of rows in the parameter table. |
| upsParameterTable_first | 1.3.6.1.4.1.818.1.1.11.10.11 | not-accessible | A list of parameter entries. The number of entries is always 16, and the value of upsParameterTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..16)): Read sequence: PDU-SET upsSetStartingAddress PDU-SET upsParametersRead PDU-GET upsParameterTableSize PDU-GET upsParameterValue 1 PDU-GET upsParameterValue 2 .. PDU-GET upsParameterValue The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsParameterTableSize. Write sequence: PDU-SET upsSetStartingAddress PDU-SET upsParameterValue 1 PDU-SET upsParameterValue 2 .. PDU-SET upsParameterValue PDU-SET upsParametersWrite | |
| upsParameterEntry_first | 1.3.6.1.4.1.818.1.1.11.10.11.1 | not-accessible | An entry containing information applicable to a particular parameter. | |
| NUM upsParameterLineIndex_first | 1.3.6.1.4.1.818.1.1.11.10.11.1.1 | PositiveInteger32 | not-accessible | The parameter line identifier. |
| I32 upsParameterValue_first | 1.3.6.1.4.1.818.1.1.11.10.11.1.2 | Integer32 | read-write | The parameter value in numerical format. |
| NUM upsStatus_first | 1.3.6.1.4.1.818.1.1.11.10.12 | NonNegativeInteger32 | read-only | The global UPS status is returned. Every bit reflects a specific status condition. Unused bits returns as 0. The status value can also be found on other commands. The value SNMP-NOSUCHNAME means 'invalid status' or 'status value non available'. Status 1 0001h upsStatusEcomodeIsOn 2 0002h upsStatusBatteryIsCharging 4 0004h upsStatusBatteryIsDischarging 8 0008h upsStatusAlarmIsActive 16 0010h upsStatusRectifierIsOn 32 0020h upsStatusLowBattery 64 0040h upsStatusOnBypass 128 0080h upsStatusMainsBypassOK 256 0100h upsStatusMainsRectifierOK 512 0200h upsStatusDetourIsOn 1024 0400h upsStatusAcousticAlarmIsOn 2048 0800h - (not used.) 4096 1000h upsStatusInverterIsOn 8192 2000h upsStatusNotInParallel (Q1 open) 16384 4000h upsStatusResetLoadOff 32768 8000h upsStatusLoadOff |
| NUM upsMainsStatisticsMBfail_first | 1.3.6.1.4.1.818.1.1.11.10.13 | NonNegativeInteger32 | read-only | Count of main bypass failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsMRfail_first | 1.3.6.1.4.1.818.1.1.11.10.14 | NonNegativeInteger32 | read-only | Count of mains rectifier failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsB2_first | 1.3.6.1.4.1.818.1.1.11.10.15 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (0..2 ms), during the last 7 days. |
| NUM upsMainsStatisticsB5_first | 1.3.6.1.4.1.818.1.1.11.10.16 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (2..5 ms), during the last 7 days. |
| NUM upsMainsStatisticsB10_first | 1.3.6.1.4.1.818.1.1.11.10.17 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (5..10 ms), during the last 7 days. |
| NUM upsMainsStatisticsB200_first | 1.3.6.1.4.1.818.1.1.11.10.18 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (10..200 ms), during the last 7 days. |
| NUM upsMainsStatisticsBypRel_first | 1.3.6.1.4.1.818.1.1.11.10.19 | NonNegativeInteger32 | read-only | Bypass reliability degree [0..100%;255]. The value NOSUCHNAME means 'not available'. |
| NUM upsTime_first | 1.3.6.1.4.1.818.1.1.11.10.20 | NonNegativeInteger32 | read-write | The current timestamp (or real-time) of the UPS. For the format, see 'Timestamp' specifications. The write-command has to comply with the correct timestamp format expected by the UPS (counter value or real-time-clock value). Missing to doing so will result in a SNMP-firstERROR, meaning 'command not supported'. It is possible to know which is the timestamp format supported by the UPS, by issuing a read-command or by reading events, which includes timestamps. |
| STR upsRequestPermission_first | 1.3.6.1.4.1.818.1.1.11.10.21 | DisplayString | write-only | An encrypted code is send to enable use of restricted write objects during a limited period of time. |
| I32 upsEventGetCode_first | 1.3.6.1.4.1.818.1.1.11.10.22 | Integer32 | write-only | The code which is used as starting point to downloading the events from the UPS event buffer. |
| TES upsEventSpinLock_first | 1.3.6.1.4.1.818.1.1.11.10.23 | TestAndIncr | read-write | A spin lock on the event subsystem. |
| TES upsParameterSpinLock_first | 1.3.6.1.4.1.818.1.1.11.10.24 | TestAndIncr | read-write | A spin lock on the parameters subsystem. |
| geUPSTraps_first | 1.3.6.1.4.1.818.1.1.11.11 | |||
| NTF upsAlarmBatteryBadTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.1 | One or more batteries have been determined to require replacement. | ||
| NTF upsAlarmOnBatteryTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.2 | An On Battery condition is restored. | ||
| NTF upsAlarmLowBatteryTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime. | ||
| NTF upsAlarmDepletedBatteryTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.4 | The UPS will be unable to sustain the present load when and if the utility power is lost) | ||
| NTF upsAlarmTempBadTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.5 | A temperature is out of tolerance. | ||
| NTF upsAlarmInputBadTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.6 | An input condition is out of tolerance. | ||
| NTF upsAlarmOutputBadTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.7 | An output condition (other than OutputOverload) is out of tolerance. | ||
| NTF upsAlarmOutputOverloadTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.8 | The output load exceeds the UPS output capacity. | ||
| NTF upsAlarmOnBypassTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.9 | The Bypass is presently engaged on the UPS. | ||
| NTF upsAlarmBypassBadTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.10 | The Bypass is out of tolerance. | ||
| NTF upsAlarmOutputOffAsRequestedTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.11 | The UPS has shutdown as requested, i.e., the output is off. | ||
| NTF upsAlarmUpsOffAsRequestedTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.12 | The entire UPS has shutdown as commanded. | ||
| NTF upsAlarmChargerFailedTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.13 | An uncorrected problem has been detected within the UPS charger subsystem. | ||
| NTF upsAlarmUpsOutputOffTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.14 | The output of the UPS is in the off state. | ||
| NTF upsAlarmUpsSystemOffTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.15 | The UPS system is in the off state. | ||
| NTF upsAlarmFanFailureTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.16 | The failure of one or more fans in the UPS has been detected. | ||
| NTF upsAlarmFuseFailureTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.17 | The failure of one or more fuses has been detected. | ||
| NTF upsAlarmGeneralFaultTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.18 | A general fault in the UPS has been detected. | ||
| NTF upsAlarmDiagnosticTestFailedTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.19 | The result of the last diagnostic test indicates a failure. | ||
| NTF upsAlarmCommunicationsLostTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.20 | A problem has been encountered in the communication between the agent and the UPS. | ||
| NTF upsAlarmAwaitingPowerTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.21 | The UPS output is off and the UPS is awaiting the return of the input power (*). | ||
| NTF upsAlarmShutdownPendingTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.22 | A upsShutdownAfterDelay countdown is underway. | ||
| NTF upsAlarmShutdownImminentTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | ||
| NTF upsAlarmTestInProgressTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | ||
| NTF upsAlarmReceptacleOffTrap_first | 1.3.6.1.4.1.818.1.1.11.11.0.25 | A receptacle has been switched off. | ||
| NTF upsAlarmBatteryBadRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.33 | A Battery bad condition is restored. | ||
| NTF upsAlarmOnBatteryRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.34 | The UPS is drawing power from mains again. | ||
| NTF upsAlarmLowBatteryRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.35 | A Low Battery condition is restored. | ||
| NTF upsAlarmDepletedBatteryRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.36 | A Depleted Battery condition is restored. | ||
| NTF upsAlarmTempBadRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.37 | A bad temperature condition is restored. | ||
| NTF upsAlarmInputBadRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.38 | An input bad condition is restored. | ||
| NTF upsAlarmOutputBadRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.39 | An output bad condition is restored. | ||
| NTF upsAlarmOutputOverloadRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.40 | An output overload condition is restored. | ||
| NTF upsAlarmOnBypassRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.41 | An On Bypass condition is restored. | ||
| NTF upsAlarmBypassBadRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.42 | A Bypass bad condition is restored. | ||
| NTF upsAlarmOutputOffAsRequestedRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.43 | A request shutdown has been restored. | ||
| NTF upsAlarmUpsOffAsRequestedRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.44 | A entire UPS command has been restored. | ||
| NTF upsAlarmChargerFailedRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.45 | A Charger Failer condition is restored. | ||
| NTF upsAlarmUpsOutputOn_first | 1.3.6.1.4.1.818.1.1.11.11.0.46 | The output of the UPS switched in the on state. | ||
| NTF upsAlarmUpsSystemOn_first | 1.3.6.1.4.1.818.1.1.11.11.0.47 | The UPS system is switched in the on state. | ||
| NTF upsAlarmFanFailureRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.48 | A Fan failure condition is restored. | ||
| NTF upsAlarmFuseFailureRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.49 | A Fuse failure condition is restored. | ||
| NTF upsAlarmGeneralFaultRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.50 | A general fault is restored. | ||
| NTF upsAlarmDiagnosticTestFailedRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.51 | A last diagnostic test indicates a failure is restored. | ||
| NTF upsAlarmCommunicationsLostRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.52 | A problem in the communication between the agent and the UPS is restored. | ||
| NTF upsAlarmAwaitingPowerRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.53 | A awaiting power condition is restored (*). | ||
| NTF upsAlarmShutdownPendingRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.54 | A upsShutdownAfterDelay countdown is restored. | ||
| NTF upsAlarmShutdownImminentRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.55 | A shutdown imminent condition is restored. | ||
| NTF upsAlarmTestInProgressRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.56 | The test is in progress is terminated. | ||
| NTF upsAlarmReceptacleOn_first | 1.3.6.1.4.1.818.1.1.11.11.0.57 | A receptacle has been switched on. | ||
| NTF upsAlarmValueLow_first | 1.3.6.1.4.1.818.1.1.11.11.0.129 | A measurement value reached a value below its low-level threshold. | ||
| NTF upsAlarmValueHigh_first | 1.3.6.1.4.1.818.1.1.11.11.0.130 | A measurement value reached a value higher than its high-level threshold. | ||
| NTF upsAlarmValueLowRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.133 | A ValueLow alarm condition is restored. | ||
| NTF upsAlarmValueHighRestored_first | 1.3.6.1.4.1.818.1.1.11.11.0.134 | A ValueHigh alarm condition is restored. | ||
| geSecondUPS | 1.3.6.1.4.1.818.1.1.12 | |||
| upsIdent_second | 1.3.6.1.4.1.818.1.1.12.1 | |||
| STR upsIdentManufacturer_second | 1.3.6.1.4.1.818.1.1.12.1.1 | DisplayString | read-only | The name of the UPS manufacturer.(*) |
| STR upsIdentModel_second | 1.3.6.1.4.1.818.1.1.12.1.2 | DisplayString | read-only | The UPS Model designation.(*) |
| STR upsIdentUPSSoftwareVersion_second | 1.3.6.1.4.1.818.1.1.12.1.3 | DisplayString | read-only | The UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.(*) |
| STR upsIdentAgentSoftwareVersion_second | 1.3.6.1.4.1.818.1.1.12.1.4 | DisplayString | read-only | The UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.(*) |
| STR upsIdentName_second | 1.3.6.1.4.1.818.1.1.12.1.5 | DisplayString | read-write | A string identifying the UPS. This object should be set by the administrator.(*) |
| STR upsIdentAttachedDevices_second | 1.3.6.1.4.1.818.1.1.12.1.6 | DisplayString | read-write | A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.(*) |
| STR upsIdentUPSSerialNumber_second | 1.3.6.1.4.1.818.1.1.12.1.7 | DisplayString | read-only | The UPS serial number |
| STR upsIdentComProtVersion_second | 1.3.6.1.4.1.818.1.1.12.1.8 | DisplayString | read-only | The IMV communication protocol version |
| NUM upsIdentOperatingTime_second | 1.3.6.1.4.1.818.1.1.12.1.9 | NonNegativeInteger32 | read-only | The present value of the operating time. total 'on' time since UPS manufactured |
| upsBattery_second | 1.3.6.1.4.1.818.1.1.12.2 | |||
| INT upsBatteryStatus_second | 1.3.6.1.4.1.818.1.1.12.2.1 | INTEGER | read-only | The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).(*) |
| NUM upsSecondsOnBattery_second | 1.3.6.1.4.1.818.1.1.12.2.2 | NonNegativeInteger32 | read-only | If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.(*) |
| NUM upsEstimatedMinutesRemaining_second | 1.3.6.1.4.1.818.1.1.12.2.3 | PositiveInteger32 | read-only | An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.(*) |
| I32 upsEstimatedChargeRemaining_second | 1.3.6.1.4.1.818.1.1.12.2.4 | Integer32 | read-only | An estimate of the battery charge remaining expressed as a percent of full charge.(*) |
| NUM upsBatteryVoltage_second | 1.3.6.1.4.1.818.1.1.12.2.5 | NonNegativeInteger32 | read-only | The magnitude of the present battery voltage.(*) |
| I32 upsBatteryCurrent_second | 1.3.6.1.4.1.818.1.1.12.2.6 | Integer32 | read-only | The present battery current.(*) |
| I32 upsBatteryTemperature_second | 1.3.6.1.4.1.818.1.1.12.2.7 | Integer32 | read-only | The ambient temperature at or near the UPS Battery casing.(*) |
| upsInput_second | 1.3.6.1.4.1.818.1.1.12.3 | |||
| C32 upsInputLineBads_second | 1.3.6.1.4.1.818.1.1.12.3.1 | Counter32 | read-only | A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.(*) |
| NUM upsInputNumLines_second | 1.3.6.1.4.1.818.1.1.12.3.2 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This variable indicates the number of rows in the input table.(*) |
| upsInputTable_second | 1.3.6.1.4.1.818.1.1.12.3.3 | not-accessible | A list of input table entries. The number of entries is given by the value of upsInputNumLines.(*) | |
| upsInputEntry_second | 1.3.6.1.4.1.818.1.1.12.3.3.1 | not-accessible | An entry containing information applicable to a particular input line.(*) | |
| NUM upsInputLineIndex_second | 1.3.6.1.4.1.818.1.1.12.3.3.1.1 | PositiveInteger32 | not-accessible | The input line identifier.(*) |
| NUM upsInputFrequency_second | 1.3.6.1.4.1.818.1.1.12.3.3.1.2 | NonNegativeInteger32 | read-only | The present input frequency.(*) |
| NUM upsInputVoltage_second | 1.3.6.1.4.1.818.1.1.12.3.3.1.3 | NonNegativeInteger32 | read-only | The magnitude of the present input voltage.(*) |
| NUM upsInputCurrent_second | 1.3.6.1.4.1.818.1.1.12.3.3.1.4 | NonNegativeInteger32 | read-only | The magnitude of the present input current.(*) |
| NUM upsInputTruePower_second | 1.3.6.1.4.1.818.1.1.12.3.3.1.5 | NonNegativeInteger32 | read-only | The magnitude of the present input true power.(*) |
| NUM upsInputVoltageMin_second | 1.3.6.1.4.1.818.1.1.12.3.3.1.6 | NonNegativeInteger32 | read-only | The lowest magnitude of the input voltage since last read out. |
| NUM upsInputVoltageMax_second | 1.3.6.1.4.1.818.1.1.12.3.3.1.7 | NonNegativeInteger32 | read-only | The highest magnitude of the input voltage since last read out. |
| upsOutput_second | 1.3.6.1.4.1.818.1.1.12.4 | |||
| INT upsOutputSource_second | 1.3.6.1.4.1.818.1.1.12.4.1 | INTEGER | read-only | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.(*) |
| NUM upsOutputFrequency_second | 1.3.6.1.4.1.818.1.1.12.4.2 | NonNegativeInteger32 | read-only | The present output frequency.(*) |
| NUM upsOutputNumLines_second | 1.3.6.1.4.1.818.1.1.12.4.3 | NonNegativeInteger32 | read-only | The number of output lines utilized in this device. This variable indicates the number of rows in the output table.(*) |
| upsOutputTable_second | 1.3.6.1.4.1.818.1.1.12.4.4 | not-accessible | A list of output table entries. The number of entries is given by the value of upsOutputNumLines.(*) | |
| upsOutputEntry_second | 1.3.6.1.4.1.818.1.1.12.4.4.1 | not-accessible | An entry containing information applicable to a particular output line.(*) | |
| NUM upsOutputLineIndex_second | 1.3.6.1.4.1.818.1.1.12.4.4.1.1 | PositiveInteger32 | not-accessible | The output line identifier.(*) |
| NUM upsOutputVoltage_second | 1.3.6.1.4.1.818.1.1.12.4.4.1.2 | NonNegativeInteger32 | read-only | The present output voltage.(*) |
| NUM upsOutputCurrent_second | 1.3.6.1.4.1.818.1.1.12.4.4.1.3 | NonNegativeInteger32 | read-only | The present output current.(*) |
| NUM upsOutputPower_second | 1.3.6.1.4.1.818.1.1.12.4.4.1.4 | NonNegativeInteger32 | read-only | The present output true power.(*) |
| I32 upsOutputPercentLoad_second | 1.3.6.1.4.1.818.1.1.12.4.4.1.5 | Integer32 | read-only | The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.(*) |
| upsBypass_second | 1.3.6.1.4.1.818.1.1.12.5 | |||
| NUM upsBypassFrequency_second | 1.3.6.1.4.1.818.1.1.12.5.1 | NonNegativeInteger32 | read-only | The present bypass frequency.(*) |
| NUM upsBypassNumLines_second | 1.3.6.1.4.1.818.1.1.12.5.2 | NonNegativeInteger32 | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.(*) |
| upsBypassTable_second | 1.3.6.1.4.1.818.1.1.12.5.3 | not-accessible | A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.(*) | |
| upsBypassEntry_second | 1.3.6.1.4.1.818.1.1.12.5.3.1 | not-accessible | An entry containing information applicable to a particular bypass input.(*) | |
| NUM upsBypassLineIndex_second | 1.3.6.1.4.1.818.1.1.12.5.3.1.1 | PositiveInteger32 | not-accessible | The bypass line identifier.(*) |
| NUM upsBypassVoltage_second | 1.3.6.1.4.1.818.1.1.12.5.3.1.2 | NonNegativeInteger32 | read-only | The present bypass voltage.(*) |
| NUM upsBypassCurrent_second | 1.3.6.1.4.1.818.1.1.12.5.3.1.3 | NonNegativeInteger32 | read-only | The present bypass current.(*) |
| NUM upsBypassPower_second | 1.3.6.1.4.1.818.1.1.12.5.3.1.4 | NonNegativeInteger32 | read-only | The present true power conveyed by the bypass.(*) |
| upsAlarm_second | 1.3.6.1.4.1.818.1.1.12.6 | |||
| G32 upsAlarmsPresent_second | 1.3.6.1.4.1.818.1.1.12.6.1 | Gauge32 | read-only | The present number of active alarm conditions.(*) |
| upsAlarmTable_second | 1.3.6.1.4.1.818.1.1.12.6.2 | not-accessible | A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent.(*) | |
| upsAlarmEntry_second | 1.3.6.1.4.1.818.1.1.12.6.2.1 | not-accessible | An entry containing information applicable to a particular alarm.(*) | |
| NUM upsAlarmId_second | 1.3.6.1.4.1.818.1.1.12.6.2.1.1 | PositiveInteger32 | not-accessible | A unique identifier for an alarm condition. This value must remain constant.(*) |
| OID upsAlarmDescr_second | 1.3.6.1.4.1.818.1.1.12.6.2.1.2 | AutonomousType | read-only | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.(*) |
| TIM upsAlarmTime_second | 1.3.6.1.4.1.818.1.1.12.6.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.(*) |
| upsWellKnownAlarms_second | 1.3.6.1.4.1.818.1.1.12.6.3 | |||
| upsAlarmBatteryBad_second | 1.3.6.1.4.1.818.1.1.12.6.3.1 | One or more batteries have been determined to require replacement.(*) | ||
| upsAlarmOnBattery_second | 1.3.6.1.4.1.818.1.1.12.6.3.2 | The UPS is drawing power from the batteries.(*) | ||
| upsAlarmLowBattery_second | 1.3.6.1.4.1.818.1.1.12.6.3.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime.(*) | ||
| upsAlarmDepletedBattery_second | 1.3.6.1.4.1.818.1.1.12.6.3.4 | The UPS will be unable to sustain the present load when and if the utility power is lost.(*) | ||
| upsAlarmTempBad_second | 1.3.6.1.4.1.818.1.1.12.6.3.5 | A temperature is out of tolerance.(*) | ||
| upsAlarmInputBad_second | 1.3.6.1.4.1.818.1.1.12.6.3.6 | An input condition is out of tolerance.(*) | ||
| upsAlarmOutputBad_second | 1.3.6.1.4.1.818.1.1.12.6.3.7 | An output condition (other than OutputOverload) is out of tolerance.(*) | ||
| upsAlarmOutputOverload_second | 1.3.6.1.4.1.818.1.1.12.6.3.8 | The output load exceeds the UPS output capacity.(*) | ||
| upsAlarmOnBypass_second | 1.3.6.1.4.1.818.1.1.12.6.3.9 | The Bypass is presently engaged on the UPS.(*) | ||
| upsAlarmBypassBad_second | 1.3.6.1.4.1.818.1.1.12.6.3.10 | The Bypass is out of tolerance.(*) | ||
| upsAlarmOutputOffAsRequested_second | 1.3.6.1.4.1.818.1.1.12.6.3.11 | The UPS has shutdown as requested, i.e., the output is off.(*) | ||
| upsAlarmUpsOffAsRequested_second | 1.3.6.1.4.1.818.1.1.12.6.3.12 | The entire UPS has shutdown as commanded.(*) | ||
| upsAlarmChargerFailed_second | 1.3.6.1.4.1.818.1.1.12.6.3.13 | An uncorrected problem has been detected within the UPS charger subsystem.(*) | ||
| upsAlarmUpsOutputOff_second | 1.3.6.1.4.1.818.1.1.12.6.3.14 | The output of the UPS is in the off state.(*) | ||
| upsAlarmUpsSystemOff_second | 1.3.6.1.4.1.818.1.1.12.6.3.15 | The UPS system is in the off state.(*) | ||
| upsAlarmFanFailure_second | 1.3.6.1.4.1.818.1.1.12.6.3.16 | The failure of one or more fans in the UPS has been detected.(*) | ||
| upsAlarmFuseFailure_second | 1.3.6.1.4.1.818.1.1.12.6.3.17 | The failure of one or more fuses has been detected.(*) | ||
| upsAlarmGeneralFault_second | 1.3.6.1.4.1.818.1.1.12.6.3.18 | A general fault in the UPS has been detected.(*) | ||
| upsAlarmDiagnosticTestFailed_second | 1.3.6.1.4.1.818.1.1.12.6.3.19 | The result of the last diagnostic test indicates a failure.(*) | ||
| upsAlarmCommunicationsLost_second | 1.3.6.1.4.1.818.1.1.12.6.3.20 | A problem has been encountered in the communications between the agent and the UPS.(*) | ||
| upsAlarmAwaitingPower_second | 1.3.6.1.4.1.818.1.1.12.6.3.21 | The UPS output is off and the UPS is awaiting the return of input power.(*) | ||
| upsAlarmShutdownPending_second | 1.3.6.1.4.1.818.1.1.12.6.3.22 | A upsShutdownAfterDelay countdown is underway.(*) | ||
| upsAlarmShutdownImminent_second | 1.3.6.1.4.1.818.1.1.12.6.3.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.(*) | ||
| upsAlarmTestInProgress_second | 1.3.6.1.4.1.818.1.1.12.6.3.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY.(*) | ||
| upsAlarmReceptacleOff_second | 1.3.6.1.4.1.818.1.1.12.6.3.25 | The receptacle are switch off | ||
| NUM upsAlarmMaskA_second | 1.3.6.1.4.1.818.1.1.12.6.4 | NonNegativeInteger32 | read-only | Specifies which alarm can be handled by the UPS. The 'Mask' parameter is a Long Integer32. The meaning of every bit is the same as for the 'upsAlarmGroupA' command. A bit having value=1 indicates that the corresponding alarm is handled by the UPS. |
| upsTest_second | 1.3.6.1.4.1.818.1.1.12.7 | |||
| OID upsTestId_second | 1.3.6.1.4.1.818.1.1.12.7.1 | OBJECT IDENTIFIER | read-write | The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned.(*) |
| TES upsTestSpinLock_second | 1.3.6.1.4.1.818.1.1.12.7.2 | TestAndIncr | read-write | A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try-again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock-value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock-value, upsTestId = requested-test) if (error-index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try-again } if (error-index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by polling upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock-value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1.(*) |
| INT upsTestResultsSummary_second | 1.3.6.1.4.1.818.1.1.12.7.3 | INTEGER | read-only | The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.(*) |
| STR upsTestResultsDetail_second | 1.3.6.1.4.1.818.1.1.12.7.4 | DisplayString | read-only | Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned.(*) |
| TIM upsTestStartTime_second | 1.3.6.1.4.1.818.1.1.12.7.5 | TimeStamp | read-only | The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0.(*) |
| NUM upsTestElapsedTime_second | 1.3.6.1.4.1.818.1.1.12.7.6 | TimeInterval | read-only | The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0.(*) |
| upsWellKnownTests_second | 1.3.6.1.4.1.818.1.1.12.7.7 | |||
| upsTestNoTestsInitiated_second | 1.3.6.1.4.1.818.1.1.12.7.7.1 | No tests have been initiated and no test is in progress.(*) | ||
| upsTestAbortTestInProgress_second | 1.3.6.1.4.1.818.1.1.12.7.7.2 | The test in progress is to be aborted / the test in progress was aborted.(*) | ||
| upsTestGeneralSystemsTest_second | 1.3.6.1.4.1.818.1.1.12.7.7.3 | The manufacturer's standard test of UPS device systems.(*) | ||
| upsTestQuickBatteryTest_second | 1.3.6.1.4.1.818.1.1.12.7.7.4 | A test that is sufficient to determine if the battery needs replacement.(*) | ||
| upsTestDeepBatteryCalibration_second | 1.3.6.1.4.1.818.1.1.12.7.7.5 | The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load.(*) | ||
| upsControl_second | 1.3.6.1.4.1.818.1.1.12.8 | |||
| INT upsShutdownType_second | 1.3.6.1.4.1.818.1.1.12.8.1 | INTEGER | read-write | This object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.(*) |
| I32 upsShutdownAfterDelay_second | 1.3.6.1.4.1.818.1.1.12.8.2 | Integer32 | read-write | Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.(*) |
| I32 upsStartupAfterDelay_second | 1.3.6.1.4.1.818.1.1.12.8.3 | Integer32 | read-write | Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.(*) |
| I32 upsRebootWithDuration_second | 1.3.6.1.4.1.818.1.1.12.8.4 | Integer32 | read-write | Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.(*) |
| INT upsAutoRestart_second | 1.3.6.1.4.1.818.1.1.12.8.5 | INTEGER | read-write | Setting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutdownAfterDelay or an internal battery depleted condition. Setting this object to 'off' will prevent the UPS system from restarting after a shutdown until an operator manually or remotely explicitly restarts it. If the UPS is in a startup or reboot countdown, then the UPS will not restart until that delay has been satisfied.(*) |
| NUM upsReceptaclesNum_second | 1.3.6.1.4.1.818.1.1.12.8.6 | NonNegativeInteger32 | read-only | The number of receptacles utilized in this device. This entry indicates the number of rows in the receptacle table. |
| upsReceptacleTable_second | 1.3.6.1.4.1.818.1.1.12.8.7 | not-accessible | A list of receptacle table entries. The number of entries is given by the value of upsReceptacleNum. | |
| upsReceptacleEntry_second | 1.3.6.1.4.1.818.1.1.12.8.7.1 | not-accessible | An entry containing information applicable to a particular receptacle. | |
| NUM upsReceptacleLineIndex_second | 1.3.6.1.4.1.818.1.1.12.8.7.1.1 | PositiveInteger32 | not-accessible | The receptacle line identifier. |
| INT upsReceptacleOnOff_second | 1.3.6.1.4.1.818.1.1.12.8.7.1.2 | INTEGER | read-write | The present state of the receptacle. Setting this object to 'on' will cause the receptacle to be turned on. Setting this object to 'off' will turn the receptacle off. If the receptacle is already in the desired state nothing will happen. After an autorestart (see upsAutoRestart) the receptacle will be on. |
| INT upsUPSMode_second | 1.3.6.1.4.1.818.1.1.12.8.8 | INTEGER | read-write | The operation mode off the UPS. Off-line indicates a mode in which the input power is transferred to the output directly or via a step-up or step-down transformer. On-line mode indicates a mode in which the output power is regenerated through some convertor. the operating mode of the UPS may be fixed, or may be selectable (e.g. an on-line UPS with ecomode) |
| INT upsRectifierOnOff_second | 1.3.6.1.4.1.818.1.1.12.8.9 | INTEGER | read-write | The present state of the rectifier. Setting this object to 'on' will cause the rectifier to be turned on. Setting this object to 'off' will turn the rectifier off. If the rectifier is already in the desired state nothing will happen. |
| INT upsBatteryChargeMethod_second | 1.3.6.1.4.1.818.1.1.12.8.10 | INTEGER | read-write | The present state of the charge method. Setting this object to 'Normal charge' will cause the battery to be charged using the normal method. Setting this object to 'Boost charge' will charge the battery in boost mode. If the charge method is already in the desired state nothing will happen. |
| INT upsInverterOnOff_second | 1.3.6.1.4.1.818.1.1.12.8.11 | INTEGER | read-write | The present state of the inverter. Setting this object to 'on' will cause the inverter to be turned on. Setting this object to 'off' will turn the inverter off. If the inverter is already in the desired state nothing will happen. |
| INT upsBypassOnOff_second | 1.3.6.1.4.1.818.1.1.12.8.12 | INTEGER | read-write | The present state of the bypass. Setting this object to 'on' will cause the bypass to be activated. Setting this object to 'off' will deactivate the bypass. If the UPS is already in the desired state nothing will happen. |
| INT upsLoadSource_second | 1.3.6.1.4.1.818.1.1.12.8.13 | INTEGER | read-write | The present source of the load. Setting this object to 'On bypass' will cause the load to be supplied by the bypass. Setting this object to 'On inverter' will cause the load to be supplied by the inverter. If the load is already supplied by the desired source nothing will happen. |
| upsConfig_second | 1.3.6.1.4.1.818.1.1.12.9 | |||
| NUM upsConfigInputVoltage_second | 1.3.6.1.4.1.818.1.1.12.9.1 | NonNegativeInteger32 | read-write | The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigInputFreq_second | 1.3.6.1.4.1.818.1.1.12.9.2 | NonNegativeInteger32 | read-write | The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVoltage_second | 1.3.6.1.4.1.818.1.1.12.9.3 | NonNegativeInteger32 | read-write | The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputFreq_second | 1.3.6.1.4.1.818.1.1.12.9.4 | NonNegativeInteger32 | read-write | The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVA_second | 1.3.6.1.4.1.818.1.1.12.9.5 | NonNegativeInteger32 | read-only | The magnitude of the nominal Volt-Amp rating.(*) |
| NUM upsConfigOutputPower_second | 1.3.6.1.4.1.818.1.1.12.9.6 | NonNegativeInteger32 | read-only | The magnitude of the nominal true power rating.(*) |
| NUM upsConfigLowBattTime_second | 1.3.6.1.4.1.818.1.1.12.9.7 | NonNegativeInteger32 | read-write | The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.(*) |
| INT upsConfigAudibleStatus_second | 1.3.6.1.4.1.818.1.1.12.9.8 | INTEGER | read-write | The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.(*) |
| NUM upsConfigLowVoltageTransferPoint_second | 1.3.6.1.4.1.818.1.1.12.9.9 | NonNegativeInteger32 | read-write | The minimum input line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigHighVoltageTransferPoint_second | 1.3.6.1.4.1.818.1.1.12.9.10 | NonNegativeInteger32 | read-write | The maximum line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigBatteryCapacity_second | 1.3.6.1.4.1.818.1.1.12.9.11 | NonNegativeInteger32 | read-write | The installed battery capacity. This value is the 'factory'-value, not the value after calibration. |
| NUM upsConfigBatteryChargeCurrent_second | 1.3.6.1.4.1.818.1.1.12.9.12 | NonNegativeInteger32 | read-write | The maximum battery charge current, including external chargers. |
| INT upsConfigNoLoadShutdown_second | 1.3.6.1.4.1.818.1.1.12.9.13 | INTEGER | read-write | Dis- or enable 'no load' shutdown from the contact interface. |
| NUM upsConfigStartDelay_second | 1.3.6.1.4.1.818.1.1.12.9.14 | PositiveInteger32 | read-write | Minimum required autonomy time before the UPS may perform an autorestart. |
| upsGetSet_second | 1.3.6.1.4.1.818.1.1.12.10 | |||
| NUM upsEventGetNext_second | 1.3.6.1.4.1.818.1.1.12.10.1 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventSetStartingTimeStamp will be used as the start value of the table with the lowest index number. |
| NUM upsEventGetPrevious_second | 1.3.6.1.4.1.818.1.1.12.10.2 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventLastTime will be used as the last value of the table with the highest index number. Returns SNMP-NOSUCHNAME for UPSs that don't support this command. |
| NUM upsEventSetStartingTimeStamp_second | 1.3.6.1.4.1.818.1.1.12.10.3 | NonNegativeInteger32 | read-write | The timestamp which is used as starting point for downloading events from the UPS event buffer |
| NUM upsEventRetreiveCurrentTimeStamp_second | 1.3.6.1.4.1.818.1.1.12.10.4 | NonNegativeInteger32 | read-only | The current timestamp is retreived from the UPS |
| NUM upsEventTableSize_second | 1.3.6.1.4.1.818.1.1.12.10.5 | NonNegativeInteger32 | read-only | The number of entries in the event table. This object indicates the number of rows in the event table. |
| upsEventTable_second | 1.3.6.1.4.1.818.1.1.12.10.6 | not-accessible | A list of event table entries. The number of entries is always 10, and the value of upsEventTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..10)): PDU-SET upsSetStartingTimeStamp PDU-SET upsEventGetNext PDU-GET upsEventTableSize PDU-GET upsEventCode,upsEventStatus,upsEventTime 1 PDU-GET upsEventCode,upsEventStatus,upsEventTime 2 .. PDU-GET upsEventCode,upsEventStatus,upsEventTime The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsEventTableSize. | |
| upsEventEntry_second | 1.3.6.1.4.1.818.1.1.12.10.6.1 | not-accessible | An entry containing information applicable to a particular event. | |
| NUM upsEventLineIndex_second | 1.3.6.1.4.1.818.1.1.12.10.6.1.1 | PositiveInteger32 | not-accessible | The event line identifier. |
| NUM upsEventCode_second | 1.3.6.1.4.1.818.1.1.12.10.6.1.2 | NonNegativeInteger32 | read-only | The event code in numerical format. |
| NUM upsEventStatus_second | 1.3.6.1.4.1.818.1.1.12.10.6.1.3 | NonNegativeInteger32 | read-only | The status of the UPS at the moment that the event was generated. The format is specified at the 'upsStatus' command. If the UPS is not able to deliver status information, then SNMP-NOSUCHNAME is returned. |
| NUM upsEventTime_second | 1.3.6.1.4.1.818.1.1.12.10.6.1.4 | NonNegativeInteger32 | read-only | The timestamp of the moment the event was generated. |
| NUM upsParametersRead_second | 1.3.6.1.4.1.818.1.1.12.10.7 | PositiveInteger32 | read-write | The number of parameters to retreive from the UPS. When this object is set the ParameterTable will be filled with the requested number of entries. The value upsParametersStartAddress will be used as the start value of the table with the lowest index number. |
| NUM upsParametersWrite_second | 1.3.6.1.4.1.818.1.1.12.10.8 | PositiveInteger32 | read-write | The number of parameters to write to the UPS. When this object is set the ParameterTable will be send to the ups. The value upsParametersStartAddress will be used for the first value of the table with the lowest index number. |
| NUM upsParametersStartAddress_second | 1.3.6.1.4.1.818.1.1.12.10.9 | NonNegativeInteger32 | read-write | The address which is used as starting point for downloading parameters from the UPS |
| NUM upsParameterTableSize_second | 1.3.6.1.4.1.818.1.1.12.10.10 | NonNegativeInteger32 | read-only | The number of entries in the parameter table. This object indicates the number of rows in the parameter table. |
| upsParameterTable_second | 1.3.6.1.4.1.818.1.1.12.10.11 | not-accessible | A list of parameter entries. The number of entries is always 16, and the value of upsParameterTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..16)): Read sequence: PDU-SET upsSetStartingAddress PDU-SET upsParametersRead PDU-GET upsParameterTableSize PDU-GET upsParameterValue 1 PDU-GET upsParameterValue 2 .. PDU-GET upsParameterValue The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsParameterTableSize. Write sequence: PDU-SET upsSetStartingAddress PDU-SET upsParameterValue 1 PDU-SET upsParameterValue 2 .. PDU-SET upsParameterValue PDU-SET upsParametersWrite | |
| upsParameterEntry_second | 1.3.6.1.4.1.818.1.1.12.10.11.1 | not-accessible | An entry containing information applicable to a particular parameter. | |
| NUM upsParameterLineIndex_second | 1.3.6.1.4.1.818.1.1.12.10.11.1.1 | PositiveInteger32 | not-accessible | The parameter line identifier. |
| I32 upsParameterValue_second | 1.3.6.1.4.1.818.1.1.12.10.11.1.2 | Integer32 | read-write | The parameter value in numerical format. |
| NUM upsStatus_second | 1.3.6.1.4.1.818.1.1.12.10.12 | NonNegativeInteger32 | read-only | The global UPS status is returned. Every bit reflects a specific status condition. Unused bits returns as 0. The status value can also be found on other commands. The value SNMP-NOSUCHNAME means 'invalid status' or 'status value non available'. Status 1 0001h upsStatusEcomodeIsOn 2 0002h upsStatusBatteryIsCharging 4 0004h upsStatusBatteryIsDischarging 8 0008h upsStatusAlarmIsActive 16 0010h upsStatusRectifierIsOn 32 0020h upsStatusLowBattery 64 0040h upsStatusOnBypass 128 0080h upsStatusMainsBypassOK 256 0100h upsStatusMainsRectifierOK 512 0200h upsStatusDetourIsOn 1024 0400h upsStatusAcousticAlarmIsOn 2048 0800h - (not used.) 4096 1000h upsStatusInverterIsOn 8192 2000h upsStatusNotInParallel (Q1 open) 16384 4000h upsStatusResetLoadOff 32768 8000h upsStatusLoadOff |
| NUM upsMainsStatisticsMBfail_second | 1.3.6.1.4.1.818.1.1.12.10.13 | NonNegativeInteger32 | read-only | Count of main bypass failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsMRfail_second | 1.3.6.1.4.1.818.1.1.12.10.14 | NonNegativeInteger32 | read-only | Count of mains rectifier failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsB2_second | 1.3.6.1.4.1.818.1.1.12.10.15 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (0..2 ms), during the last 7 days. |
| NUM upsMainsStatisticsB5_second | 1.3.6.1.4.1.818.1.1.12.10.16 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (2..5 ms), during the last 7 days. |
| NUM upsMainsStatisticsB10_second | 1.3.6.1.4.1.818.1.1.12.10.17 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (5..10 ms), during the last 7 days. |
| NUM upsMainsStatisticsB200_second | 1.3.6.1.4.1.818.1.1.12.10.18 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (10..200 ms), during the last 7 days. |
| NUM upsMainsStatisticsBypRel_second | 1.3.6.1.4.1.818.1.1.12.10.19 | NonNegativeInteger32 | read-only | Bypass reliability degree [0..100%;255]. The value NOSUCHNAME means 'not available'. |
| NUM upsTime_second | 1.3.6.1.4.1.818.1.1.12.10.20 | NonNegativeInteger32 | read-write | The current timestamp (or real-time) of the UPS. For the format, see 'Timestamp' specifications. The write-command has to comply with the correct timestamp format expected by the UPS (counter value or real-time-clock value). Missing to doing so will result in a SNMP-secondERROR, meaning 'command not supported'. It is possible to know which is the timestamp format supported by the UPS, by issuing a read-command or by reading events, which includes timestamps. |
| STR upsRequestPermission_second | 1.3.6.1.4.1.818.1.1.12.10.21 | DisplayString | write-only | An encrypted code is send to enable use of restricted write objects during a limited period of time. |
| I32 upsEventGetCode_second | 1.3.6.1.4.1.818.1.1.12.10.22 | Integer32 | write-only | The code which is used as starting point to downloading the events from the UPS event buffer. |
| TES upsEventSpinLock_second | 1.3.6.1.4.1.818.1.1.12.10.23 | TestAndIncr | read-write | A spin lock on the event subsystem. |
| TES upsParameterSpinLock_second | 1.3.6.1.4.1.818.1.1.12.10.24 | TestAndIncr | read-write | A spin lock on the parameters subsystem. |
| geUPSTraps_second | 1.3.6.1.4.1.818.1.1.12.11 | |||
| NTF upsAlarmBatteryBadTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.1 | One or more batteries have been determined to require replacement. | ||
| NTF upsAlarmOnBatteryTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.2 | An On Battery condition is restored. | ||
| NTF upsAlarmLowBatteryTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime. | ||
| NTF upsAlarmDepletedBatteryTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.4 | The UPS will be unable to sustain the present load when and if the utility power is lost) | ||
| NTF upsAlarmTempBadTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.5 | A temperature is out of tolerance. | ||
| NTF upsAlarmInputBadTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.6 | An input condition is out of tolerance. | ||
| NTF upsAlarmOutputBadTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.7 | An output condition (other than OutputOverload) is out of tolerance. | ||
| NTF upsAlarmOutputOverloadTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.8 | The output load exceeds the UPS output capacity. | ||
| NTF upsAlarmOnBypassTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.9 | The Bypass is presently engaged on the UPS. | ||
| NTF upsAlarmBypassBadTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.10 | The Bypass is out of tolerance. | ||
| NTF upsAlarmOutputOffAsRequestedTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.11 | The UPS has shutdown as requested, i.e., the output is off. | ||
| NTF upsAlarmUpsOffAsRequestedTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.12 | The entire UPS has shutdown as commanded. | ||
| NTF upsAlarmChargerFailedTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.13 | An uncorrected problem has been detected within the UPS charger subsystem. | ||
| NTF upsAlarmUpsOutputOffTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.14 | The output of the UPS is in the off state. | ||
| NTF upsAlarmUpsSystemOffTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.15 | The UPS system is in the off state. | ||
| NTF upsAlarmFanFailureTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.16 | The failure of one or more fans in the UPS has been detected. | ||
| NTF upsAlarmFuseFailureTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.17 | The failure of one or more fuses has been detected. | ||
| NTF upsAlarmGeneralFaultTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.18 | A general fault in the UPS has been detected. | ||
| NTF upsAlarmDiagnosticTestFailedTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.19 | The result of the last diagnostic test indicates a failure. | ||
| NTF upsAlarmCommunicationsLostTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.20 | A problem has been encountered in the communication between the agent and the UPS. | ||
| NTF upsAlarmAwaitingPowerTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.21 | The UPS output is off and the UPS is awaiting the return of the input power (*). | ||
| NTF upsAlarmShutdownPendingTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.22 | A upsShutdownAfterDelay countdown is underway. | ||
| NTF upsAlarmShutdownImminentTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | ||
| NTF upsAlarmTestInProgressTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | ||
| NTF upsAlarmReceptacleOffTrap_second | 1.3.6.1.4.1.818.1.1.12.11.0.25 | A receptacle has been switched off. | ||
| NTF upsAlarmBatteryBadRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.33 | A Battery bad condition is restored. | ||
| NTF upsAlarmOnBatteryRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.34 | The UPS is drawing power from mains again. | ||
| NTF upsAlarmLowBatteryRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.35 | A Low Battery condition is restored. | ||
| NTF upsAlarmDepletedBatteryRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.36 | A Depleted Battery condition is restored. | ||
| NTF upsAlarmTempBadRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.37 | A bad temperature condition is restored. | ||
| NTF upsAlarmInputBadRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.38 | An input bad condition is restored. | ||
| NTF upsAlarmOutputBadRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.39 | An output bad condition is restored. | ||
| NTF upsAlarmOutputOverloadRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.40 | An output overload condition is restored. | ||
| NTF upsAlarmOnBypassRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.41 | An On Bypass condition is restored. | ||
| NTF upsAlarmBypassBadRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.42 | A Bypass bad condition is restored. | ||
| NTF upsAlarmOutputOffAsRequestedRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.43 | A request shutdown has been restored. | ||
| NTF upsAlarmUpsOffAsRequestedRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.44 | A entire UPS command has been restored. | ||
| NTF upsAlarmChargerFailedRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.45 | A Charger Failer condition is restored. | ||
| NTF upsAlarmUpsOutputOn_second | 1.3.6.1.4.1.818.1.1.12.11.0.46 | The output of the UPS switched in the on state. | ||
| NTF upsAlarmUpsSystemOn_second | 1.3.6.1.4.1.818.1.1.12.11.0.47 | The UPS system is switched in the on state. | ||
| NTF upsAlarmFanFailureRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.48 | A Fan failure condition is restored. | ||
| NTF upsAlarmFuseFailureRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.49 | A Fuse failure condition is restored. | ||
| NTF upsAlarmGeneralFaultRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.50 | A general fault is restored. | ||
| NTF upsAlarmDiagnosticTestFailedRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.51 | A last diagnostic test indicates a failure is restored. | ||
| NTF upsAlarmCommunicationsLostRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.52 | A problem in the communication between the agent and the UPS is restored. | ||
| NTF upsAlarmAwaitingPowerRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.53 | A awaiting power condition is restored (*). | ||
| NTF upsAlarmShutdownPendingRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.54 | A upsShutdownAfterDelay countdown is restored. | ||
| NTF upsAlarmShutdownImminentRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.55 | A shutdown imminent condition is restored. | ||
| NTF upsAlarmTestInProgressRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.56 | The test is in progress is terminated. | ||
| NTF upsAlarmReceptacleOn_second | 1.3.6.1.4.1.818.1.1.12.11.0.57 | A receptacle has been switched on. | ||
| NTF upsAlarmValueLow_second | 1.3.6.1.4.1.818.1.1.12.11.0.129 | A measurement value reached a value below its low-level threshold. | ||
| NTF upsAlarmValueHigh_second | 1.3.6.1.4.1.818.1.1.12.11.0.130 | A measurement value reached a value higher than its high-level threshold. | ||
| NTF upsAlarmValueLowRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.133 | A ValueLow alarm condition is restored. | ||
| NTF upsAlarmValueHighRestored_second | 1.3.6.1.4.1.818.1.1.12.11.0.134 | A ValueHigh alarm condition is restored. | ||
| geThirdUPS | 1.3.6.1.4.1.818.1.1.13 | |||
| upsIdent_third | 1.3.6.1.4.1.818.1.1.13.1 | |||
| STR upsIdentManufacturer_third | 1.3.6.1.4.1.818.1.1.13.1.1 | DisplayString | read-only | The name of the UPS manufacturer.(*) |
| STR upsIdentModel_third | 1.3.6.1.4.1.818.1.1.13.1.2 | DisplayString | read-only | The UPS Model designation.(*) |
| STR upsIdentUPSSoftwareVersion_third | 1.3.6.1.4.1.818.1.1.13.1.3 | DisplayString | read-only | The UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.(*) |
| STR upsIdentAgentSoftwareVersion_third | 1.3.6.1.4.1.818.1.1.13.1.4 | DisplayString | read-only | The UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.(*) |
| STR upsIdentName_third | 1.3.6.1.4.1.818.1.1.13.1.5 | DisplayString | read-write | A string identifying the UPS. This object should be set by the administrator.(*) |
| STR upsIdentAttachedDevices_third | 1.3.6.1.4.1.818.1.1.13.1.6 | DisplayString | read-write | A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.(*) |
| STR upsIdentUPSSerialNumber_third | 1.3.6.1.4.1.818.1.1.13.1.7 | DisplayString | read-only | The UPS serial number |
| STR upsIdentComProtVersion_third | 1.3.6.1.4.1.818.1.1.13.1.8 | DisplayString | read-only | The IMV communication protocol version |
| NUM upsIdentOperatingTime_third | 1.3.6.1.4.1.818.1.1.13.1.9 | NonNegativeInteger32 | read-only | The present value of the operating time. total 'on' time since UPS manufactured |
| upsBattery_third | 1.3.6.1.4.1.818.1.1.13.2 | |||
| INT upsBatteryStatus_third | 1.3.6.1.4.1.818.1.1.13.2.1 | INTEGER | read-only | The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).(*) |
| NUM upsSecondsOnBattery_third | 1.3.6.1.4.1.818.1.1.13.2.2 | NonNegativeInteger32 | read-only | If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.(*) |
| NUM upsEstimatedMinutesRemaining_third | 1.3.6.1.4.1.818.1.1.13.2.3 | PositiveInteger32 | read-only | An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.(*) |
| I32 upsEstimatedChargeRemaining_third | 1.3.6.1.4.1.818.1.1.13.2.4 | Integer32 | read-only | An estimate of the battery charge remaining expressed as a percent of full charge.(*) |
| NUM upsBatteryVoltage_third | 1.3.6.1.4.1.818.1.1.13.2.5 | NonNegativeInteger32 | read-only | The magnitude of the present battery voltage.(*) |
| I32 upsBatteryCurrent_third | 1.3.6.1.4.1.818.1.1.13.2.6 | Integer32 | read-only | The present battery current.(*) |
| I32 upsBatteryTemperature_third | 1.3.6.1.4.1.818.1.1.13.2.7 | Integer32 | read-only | The ambient temperature at or near the UPS Battery casing.(*) |
| upsInput_third | 1.3.6.1.4.1.818.1.1.13.3 | |||
| C32 upsInputLineBads_third | 1.3.6.1.4.1.818.1.1.13.3.1 | Counter32 | read-only | A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.(*) |
| NUM upsInputNumLines_third | 1.3.6.1.4.1.818.1.1.13.3.2 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This variable indicates the number of rows in the input table.(*) |
| upsInputTable_third | 1.3.6.1.4.1.818.1.1.13.3.3 | not-accessible | A list of input table entries. The number of entries is given by the value of upsInputNumLines.(*) | |
| upsInputEntry_third | 1.3.6.1.4.1.818.1.1.13.3.3.1 | not-accessible | An entry containing information applicable to a particular input line.(*) | |
| NUM upsInputLineIndex_third | 1.3.6.1.4.1.818.1.1.13.3.3.1.1 | PositiveInteger32 | not-accessible | The input line identifier.(*) |
| NUM upsInputFrequency_third | 1.3.6.1.4.1.818.1.1.13.3.3.1.2 | NonNegativeInteger32 | read-only | The present input frequency.(*) |
| NUM upsInputVoltage_third | 1.3.6.1.4.1.818.1.1.13.3.3.1.3 | NonNegativeInteger32 | read-only | The magnitude of the present input voltage.(*) |
| NUM upsInputCurrent_third | 1.3.6.1.4.1.818.1.1.13.3.3.1.4 | NonNegativeInteger32 | read-only | The magnitude of the present input current.(*) |
| NUM upsInputTruePower_third | 1.3.6.1.4.1.818.1.1.13.3.3.1.5 | NonNegativeInteger32 | read-only | The magnitude of the present input true power.(*) |
| NUM upsInputVoltageMin_third | 1.3.6.1.4.1.818.1.1.13.3.3.1.6 | NonNegativeInteger32 | read-only | The lowest magnitude of the input voltage since last read out. |
| NUM upsInputVoltageMax_third | 1.3.6.1.4.1.818.1.1.13.3.3.1.7 | NonNegativeInteger32 | read-only | The highest magnitude of the input voltage since last read out. |
| upsOutput_third | 1.3.6.1.4.1.818.1.1.13.4 | |||
| INT upsOutputSource_third | 1.3.6.1.4.1.818.1.1.13.4.1 | INTEGER | read-only | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.(*) |
| NUM upsOutputFrequency_third | 1.3.6.1.4.1.818.1.1.13.4.2 | NonNegativeInteger32 | read-only | The present output frequency.(*) |
| NUM upsOutputNumLines_third | 1.3.6.1.4.1.818.1.1.13.4.3 | NonNegativeInteger32 | read-only | The number of output lines utilized in this device. This variable indicates the number of rows in the output table.(*) |
| upsOutputTable_third | 1.3.6.1.4.1.818.1.1.13.4.4 | not-accessible | A list of output table entries. The number of entries is given by the value of upsOutputNumLines.(*) | |
| upsOutputEntry_third | 1.3.6.1.4.1.818.1.1.13.4.4.1 | not-accessible | An entry containing information applicable to a particular output line.(*) | |
| NUM upsOutputLineIndex_third | 1.3.6.1.4.1.818.1.1.13.4.4.1.1 | PositiveInteger32 | not-accessible | The output line identifier.(*) |
| NUM upsOutputVoltage_third | 1.3.6.1.4.1.818.1.1.13.4.4.1.2 | NonNegativeInteger32 | read-only | The present output voltage.(*) |
| NUM upsOutputCurrent_third | 1.3.6.1.4.1.818.1.1.13.4.4.1.3 | NonNegativeInteger32 | read-only | The present output current.(*) |
| NUM upsOutputPower_third | 1.3.6.1.4.1.818.1.1.13.4.4.1.4 | NonNegativeInteger32 | read-only | The present output true power.(*) |
| I32 upsOutputPercentLoad_third | 1.3.6.1.4.1.818.1.1.13.4.4.1.5 | Integer32 | read-only | The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.(*) |
| upsBypass_third | 1.3.6.1.4.1.818.1.1.13.5 | |||
| NUM upsBypassFrequency_third | 1.3.6.1.4.1.818.1.1.13.5.1 | NonNegativeInteger32 | read-only | The present bypass frequency.(*) |
| NUM upsBypassNumLines_third | 1.3.6.1.4.1.818.1.1.13.5.2 | NonNegativeInteger32 | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.(*) |
| upsBypassTable_third | 1.3.6.1.4.1.818.1.1.13.5.3 | not-accessible | A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.(*) | |
| upsBypassEntry_third | 1.3.6.1.4.1.818.1.1.13.5.3.1 | not-accessible | An entry containing information applicable to a particular bypass input.(*) | |
| NUM upsBypassLineIndex_third | 1.3.6.1.4.1.818.1.1.13.5.3.1.1 | PositiveInteger32 | not-accessible | The bypass line identifier.(*) |
| NUM upsBypassVoltage_third | 1.3.6.1.4.1.818.1.1.13.5.3.1.2 | NonNegativeInteger32 | read-only | The present bypass voltage.(*) |
| NUM upsBypassCurrent_third | 1.3.6.1.4.1.818.1.1.13.5.3.1.3 | NonNegativeInteger32 | read-only | The present bypass current.(*) |
| NUM upsBypassPower_third | 1.3.6.1.4.1.818.1.1.13.5.3.1.4 | NonNegativeInteger32 | read-only | The present true power conveyed by the bypass.(*) |
| upsAlarm_third | 1.3.6.1.4.1.818.1.1.13.6 | |||
| G32 upsAlarmsPresent_third | 1.3.6.1.4.1.818.1.1.13.6.1 | Gauge32 | read-only | The present number of active alarm conditions.(*) |
| upsAlarmTable_third | 1.3.6.1.4.1.818.1.1.13.6.2 | not-accessible | A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent.(*) | |
| upsAlarmEntry_third | 1.3.6.1.4.1.818.1.1.13.6.2.1 | not-accessible | An entry containing information applicable to a particular alarm.(*) | |
| NUM upsAlarmId_third | 1.3.6.1.4.1.818.1.1.13.6.2.1.1 | PositiveInteger32 | not-accessible | A unique identifier for an alarm condition. This value must remain constant.(*) |
| OID upsAlarmDescr_third | 1.3.6.1.4.1.818.1.1.13.6.2.1.2 | AutonomousType | read-only | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.(*) |
| TIM upsAlarmTime_third | 1.3.6.1.4.1.818.1.1.13.6.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.(*) |
| upsWellKnownAlarms_third | 1.3.6.1.4.1.818.1.1.13.6.3 | |||
| upsAlarmBatteryBad_third | 1.3.6.1.4.1.818.1.1.13.6.3.1 | One or more batteries have been determined to require replacement.(*) | ||
| upsAlarmOnBattery_third | 1.3.6.1.4.1.818.1.1.13.6.3.2 | The UPS is drawing power from the batteries.(*) | ||
| upsAlarmLowBattery_third | 1.3.6.1.4.1.818.1.1.13.6.3.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime.(*) | ||
| upsAlarmDepletedBattery_third | 1.3.6.1.4.1.818.1.1.13.6.3.4 | The UPS will be unable to sustain the present load when and if the utility power is lost.(*) | ||
| upsAlarmTempBad_third | 1.3.6.1.4.1.818.1.1.13.6.3.5 | A temperature is out of tolerance.(*) | ||
| upsAlarmInputBad_third | 1.3.6.1.4.1.818.1.1.13.6.3.6 | An input condition is out of tolerance.(*) | ||
| upsAlarmOutputBad_third | 1.3.6.1.4.1.818.1.1.13.6.3.7 | An output condition (other than OutputOverload) is out of tolerance.(*) | ||
| upsAlarmOutputOverload_third | 1.3.6.1.4.1.818.1.1.13.6.3.8 | The output load exceeds the UPS output capacity.(*) | ||
| upsAlarmOnBypass_third | 1.3.6.1.4.1.818.1.1.13.6.3.9 | The Bypass is presently engaged on the UPS.(*) | ||
| upsAlarmBypassBad_third | 1.3.6.1.4.1.818.1.1.13.6.3.10 | The Bypass is out of tolerance.(*) | ||
| upsAlarmOutputOffAsRequested_third | 1.3.6.1.4.1.818.1.1.13.6.3.11 | The UPS has shutdown as requested, i.e., the output is off.(*) | ||
| upsAlarmUpsOffAsRequested_third | 1.3.6.1.4.1.818.1.1.13.6.3.12 | The entire UPS has shutdown as commanded.(*) | ||
| upsAlarmChargerFailed_third | 1.3.6.1.4.1.818.1.1.13.6.3.13 | An uncorrected problem has been detected within the UPS charger subsystem.(*) | ||
| upsAlarmUpsOutputOff_third | 1.3.6.1.4.1.818.1.1.13.6.3.14 | The output of the UPS is in the off state.(*) | ||
| upsAlarmUpsSystemOff_third | 1.3.6.1.4.1.818.1.1.13.6.3.15 | The UPS system is in the off state.(*) | ||
| upsAlarmFanFailure_third | 1.3.6.1.4.1.818.1.1.13.6.3.16 | The failure of one or more fans in the UPS has been detected.(*) | ||
| upsAlarmFuseFailure_third | 1.3.6.1.4.1.818.1.1.13.6.3.17 | The failure of one or more fuses has been detected.(*) | ||
| upsAlarmGeneralFault_third | 1.3.6.1.4.1.818.1.1.13.6.3.18 | A general fault in the UPS has been detected.(*) | ||
| upsAlarmDiagnosticTestFailed_third | 1.3.6.1.4.1.818.1.1.13.6.3.19 | The result of the last diagnostic test indicates a failure.(*) | ||
| upsAlarmCommunicationsLost_third | 1.3.6.1.4.1.818.1.1.13.6.3.20 | A problem has been encountered in the communications between the agent and the UPS.(*) | ||
| upsAlarmAwaitingPower_third | 1.3.6.1.4.1.818.1.1.13.6.3.21 | The UPS output is off and the UPS is awaiting the return of input power.(*) | ||
| upsAlarmShutdownPending_third | 1.3.6.1.4.1.818.1.1.13.6.3.22 | A upsShutdownAfterDelay countdown is underway.(*) | ||
| upsAlarmShutdownImminent_third | 1.3.6.1.4.1.818.1.1.13.6.3.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.(*) | ||
| upsAlarmTestInProgress_third | 1.3.6.1.4.1.818.1.1.13.6.3.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY.(*) | ||
| upsAlarmReceptacleOff_third | 1.3.6.1.4.1.818.1.1.13.6.3.25 | The receptacle are switch off | ||
| NUM upsAlarmMaskA_third | 1.3.6.1.4.1.818.1.1.13.6.4 | NonNegativeInteger32 | read-only | Specifies which alarm can be handled by the UPS. The 'Mask' parameter is a Long Integer32. The meaning of every bit is the same as for the 'upsAlarmGroupA' command. A bit having value=1 indicates that the corresponding alarm is handled by the UPS. |
| upsTest_third | 1.3.6.1.4.1.818.1.1.13.7 | |||
| OID upsTestId_third | 1.3.6.1.4.1.818.1.1.13.7.1 | OBJECT IDENTIFIER | read-write | The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned.(*) |
| TES upsTestSpinLock_third | 1.3.6.1.4.1.818.1.1.13.7.2 | TestAndIncr | read-write | A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try-again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock-value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock-value, upsTestId = requested-test) if (error-index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try-again } if (error-index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by polling upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock-value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1.(*) |
| INT upsTestResultsSummary_third | 1.3.6.1.4.1.818.1.1.13.7.3 | INTEGER | read-only | The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.(*) |
| STR upsTestResultsDetail_third | 1.3.6.1.4.1.818.1.1.13.7.4 | DisplayString | read-only | Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned.(*) |
| TIM upsTestStartTime_third | 1.3.6.1.4.1.818.1.1.13.7.5 | TimeStamp | read-only | The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0.(*) |
| NUM upsTestElapsedTime_third | 1.3.6.1.4.1.818.1.1.13.7.6 | TimeInterval | read-only | The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0.(*) |
| upsWellKnownTests_third | 1.3.6.1.4.1.818.1.1.13.7.7 | |||
| upsTestNoTestsInitiated_third | 1.3.6.1.4.1.818.1.1.13.7.7.1 | No tests have been initiated and no test is in progress.(*) | ||
| upsTestAbortTestInProgress_third | 1.3.6.1.4.1.818.1.1.13.7.7.2 | The test in progress is to be aborted / the test in progress was aborted.(*) | ||
| upsTestGeneralSystemsTest_third | 1.3.6.1.4.1.818.1.1.13.7.7.3 | The manufacturer's standard test of UPS device systems.(*) | ||
| upsTestQuickBatteryTest_third | 1.3.6.1.4.1.818.1.1.13.7.7.4 | A test that is sufficient to determine if the battery needs replacement.(*) | ||
| upsTestDeepBatteryCalibration_third | 1.3.6.1.4.1.818.1.1.13.7.7.5 | The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load.(*) | ||
| upsControl_third | 1.3.6.1.4.1.818.1.1.13.8 | |||
| INT upsShutdownType_third | 1.3.6.1.4.1.818.1.1.13.8.1 | INTEGER | read-write | This object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.(*) |
| I32 upsShutdownAfterDelay_third | 1.3.6.1.4.1.818.1.1.13.8.2 | Integer32 | read-write | Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.(*) |
| I32 upsStartupAfterDelay_third | 1.3.6.1.4.1.818.1.1.13.8.3 | Integer32 | read-write | Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.(*) |
| I32 upsRebootWithDuration_third | 1.3.6.1.4.1.818.1.1.13.8.4 | Integer32 | read-write | Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.(*) |
| INT upsAutoRestart_third | 1.3.6.1.4.1.818.1.1.13.8.5 | INTEGER | read-write | Setting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutdownAfterDelay or an internal battery depleted condition. Setting this object to 'off' will prevent the UPS system from restarting after a shutdown until an operator manually or remotely explicitly restarts it. If the UPS is in a startup or reboot countdown, then the UPS will not restart until that delay has been satisfied.(*) |
| NUM upsReceptaclesNum_third | 1.3.6.1.4.1.818.1.1.13.8.6 | NonNegativeInteger32 | read-only | The number of receptacles utilized in this device. This entry indicates the number of rows in the receptacle table. |
| upsReceptacleTable_third | 1.3.6.1.4.1.818.1.1.13.8.7 | not-accessible | A list of receptacle table entries. The number of entries is given by the value of upsReceptacleNum. | |
| upsReceptacleEntry_third | 1.3.6.1.4.1.818.1.1.13.8.7.1 | not-accessible | An entry containing information applicable to a particular receptacle. | |
| NUM upsReceptacleLineIndex_third | 1.3.6.1.4.1.818.1.1.13.8.7.1.1 | PositiveInteger32 | not-accessible | The receptacle line identifier. |
| INT upsReceptacleOnOff_third | 1.3.6.1.4.1.818.1.1.13.8.7.1.2 | INTEGER | read-write | The present state of the receptacle. Setting this object to 'on' will cause the receptacle to be turned on. Setting this object to 'off' will turn the receptacle off. If the receptacle is already in the desired state nothing will happen. After an autorestart (see upsAutoRestart) the receptacle will be on. |
| INT upsUPSMode_third | 1.3.6.1.4.1.818.1.1.13.8.8 | INTEGER | read-write | The operation mode off the UPS. Off-line indicates a mode in which the input power is transferred to the output directly or via a step-up or step-down transformer. On-line mode indicates a mode in which the output power is regenerated through some convertor. the operating mode of the UPS may be fixed, or may be selectable (e.g. an on-line UPS with ecomode) |
| INT upsRectifierOnOff_third | 1.3.6.1.4.1.818.1.1.13.8.9 | INTEGER | read-write | The present state of the rectifier. Setting this object to 'on' will cause the rectifier to be turned on. Setting this object to 'off' will turn the rectifier off. If the rectifier is already in the desired state nothing will happen. |
| INT upsBatteryChargeMethod_third | 1.3.6.1.4.1.818.1.1.13.8.10 | INTEGER | read-write | The present state of the charge method. Setting this object to 'Normal charge' will cause the battery to be charged using the normal method. Setting this object to 'Boost charge' will charge the battery in boost mode. If the charge method is already in the desired state nothing will happen. |
| INT upsInverterOnOff_third | 1.3.6.1.4.1.818.1.1.13.8.11 | INTEGER | read-write | The present state of the inverter. Setting this object to 'on' will cause the inverter to be turned on. Setting this object to 'off' will turn the inverter off. If the inverter is already in the desired state nothing will happen. |
| INT upsBypassOnOff_third | 1.3.6.1.4.1.818.1.1.13.8.12 | INTEGER | read-write | The present state of the bypass. Setting this object to 'on' will cause the bypass to be activated. Setting this object to 'off' will deactivate the bypass. If the UPS is already in the desired state nothing will happen. |
| INT upsLoadSource_third | 1.3.6.1.4.1.818.1.1.13.8.13 | INTEGER | read-write | The present source of the load. Setting this object to 'On bypass' will cause the load to be supplied by the bypass. Setting this object to 'On inverter' will cause the load to be supplied by the inverter. If the load is already supplied by the desired source nothing will happen. |
| upsConfig_third | 1.3.6.1.4.1.818.1.1.13.9 | |||
| NUM upsConfigInputVoltage_third | 1.3.6.1.4.1.818.1.1.13.9.1 | NonNegativeInteger32 | read-write | The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigInputFreq_third | 1.3.6.1.4.1.818.1.1.13.9.2 | NonNegativeInteger32 | read-write | The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVoltage_third | 1.3.6.1.4.1.818.1.1.13.9.3 | NonNegativeInteger32 | read-write | The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputFreq_third | 1.3.6.1.4.1.818.1.1.13.9.4 | NonNegativeInteger32 | read-write | The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVA_third | 1.3.6.1.4.1.818.1.1.13.9.5 | NonNegativeInteger32 | read-only | The magnitude of the nominal Volt-Amp rating.(*) |
| NUM upsConfigOutputPower_third | 1.3.6.1.4.1.818.1.1.13.9.6 | NonNegativeInteger32 | read-only | The magnitude of the nominal true power rating.(*) |
| NUM upsConfigLowBattTime_third | 1.3.6.1.4.1.818.1.1.13.9.7 | NonNegativeInteger32 | read-write | The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.(*) |
| INT upsConfigAudibleStatus_third | 1.3.6.1.4.1.818.1.1.13.9.8 | INTEGER | read-write | The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.(*) |
| NUM upsConfigLowVoltageTransferPoint_third | 1.3.6.1.4.1.818.1.1.13.9.9 | NonNegativeInteger32 | read-write | The minimum input line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigHighVoltageTransferPoint_third | 1.3.6.1.4.1.818.1.1.13.9.10 | NonNegativeInteger32 | read-write | The maximum line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigBatteryCapacity_third | 1.3.6.1.4.1.818.1.1.13.9.11 | NonNegativeInteger32 | read-write | The installed battery capacity. This value is the 'factory'-value, not the value after calibration. |
| NUM upsConfigBatteryChargeCurrent_third | 1.3.6.1.4.1.818.1.1.13.9.12 | NonNegativeInteger32 | read-write | The maximum battery charge current, including external chargers. |
| INT upsConfigNoLoadShutdown_third | 1.3.6.1.4.1.818.1.1.13.9.13 | INTEGER | read-write | Dis- or enable 'no load' shutdown from the contact interface. |
| NUM upsConfigStartDelay_third | 1.3.6.1.4.1.818.1.1.13.9.14 | PositiveInteger32 | read-write | Minimum required autonomy time before the UPS may perform an autorestart. |
| upsGetSet_third | 1.3.6.1.4.1.818.1.1.13.10 | |||
| NUM upsEventGetNext_third | 1.3.6.1.4.1.818.1.1.13.10.1 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventSetStartingTimeStamp will be used as the start value of the table with the lowest index number. |
| NUM upsEventGetPrevious_third | 1.3.6.1.4.1.818.1.1.13.10.2 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventLastTime will be used as the last value of the table with the highest index number. Returns SNMP-NOSUCHNAME for UPSs that don't support this command. |
| NUM upsEventSetStartingTimeStamp_third | 1.3.6.1.4.1.818.1.1.13.10.3 | NonNegativeInteger32 | read-write | The timestamp which is used as starting point for downloading events from the UPS event buffer |
| NUM upsEventRetreiveCurrentTimeStamp_third | 1.3.6.1.4.1.818.1.1.13.10.4 | NonNegativeInteger32 | read-only | The current timestamp is retreived from the UPS |
| NUM upsEventTableSize_third | 1.3.6.1.4.1.818.1.1.13.10.5 | NonNegativeInteger32 | read-only | The number of entries in the event table. This object indicates the number of rows in the event table. |
| upsEventTable_third | 1.3.6.1.4.1.818.1.1.13.10.6 | not-accessible | A list of event table entries. The number of entries is always 10, and the value of upsEventTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..10)): PDU-SET upsSetStartingTimeStamp PDU-SET upsEventGetNext PDU-GET upsEventTableSize PDU-GET upsEventCode,upsEventStatus,upsEventTime 1 PDU-GET upsEventCode,upsEventStatus,upsEventTime 2 .. PDU-GET upsEventCode,upsEventStatus,upsEventTime The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsEventTableSize. | |
| upsEventEntry_third | 1.3.6.1.4.1.818.1.1.13.10.6.1 | not-accessible | An entry containing information applicable to a particular event. | |
| NUM upsEventLineIndex_third | 1.3.6.1.4.1.818.1.1.13.10.6.1.1 | PositiveInteger32 | not-accessible | The event line identifier. |
| NUM upsEventCode_third | 1.3.6.1.4.1.818.1.1.13.10.6.1.2 | NonNegativeInteger32 | read-only | The event code in numerical format. |
| NUM upsEventStatus_third | 1.3.6.1.4.1.818.1.1.13.10.6.1.3 | NonNegativeInteger32 | read-only | The status of the UPS at the moment that the event was generated. The format is specified at the 'upsStatus' command. If the UPS is not able to deliver status information, then SNMP-NOSUCHNAME is returned. |
| NUM upsEventTime_third | 1.3.6.1.4.1.818.1.1.13.10.6.1.4 | NonNegativeInteger32 | read-only | The timestamp of the moment the event was generated. |
| NUM upsParametersRead_third | 1.3.6.1.4.1.818.1.1.13.10.7 | PositiveInteger32 | read-write | The number of parameters to retreive from the UPS. When this object is set the ParameterTable will be filled with the requested number of entries. The value upsParametersStartAddress will be used as the start value of the table with the lowest index number. |
| NUM upsParametersWrite_third | 1.3.6.1.4.1.818.1.1.13.10.8 | PositiveInteger32 | read-write | The number of parameters to write to the UPS. When this object is set the ParameterTable will be send to the ups. The value upsParametersStartAddress will be used for the first value of the table with the lowest index number. |
| NUM upsParametersStartAddress_third | 1.3.6.1.4.1.818.1.1.13.10.9 | NonNegativeInteger32 | read-write | The address which is used as starting point for downloading parameters from the UPS |
| NUM upsParameterTableSize_third | 1.3.6.1.4.1.818.1.1.13.10.10 | NonNegativeInteger32 | read-only | The number of entries in the parameter table. This object indicates the number of rows in the parameter table. |
| upsParameterTable_third | 1.3.6.1.4.1.818.1.1.13.10.11 | not-accessible | A list of parameter entries. The number of entries is always 16, and the value of upsParameterTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..16)): Read sequence: PDU-SET upsSetStartingAddress PDU-SET upsParametersRead PDU-GET upsParameterTableSize PDU-GET upsParameterValue 1 PDU-GET upsParameterValue 2 .. PDU-GET upsParameterValue The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsParameterTableSize. Write sequence: PDU-SET upsSetStartingAddress PDU-SET upsParameterValue 1 PDU-SET upsParameterValue 2 .. PDU-SET upsParameterValue PDU-SET upsParametersWrite | |
| upsParameterEntry_third | 1.3.6.1.4.1.818.1.1.13.10.11.1 | not-accessible | An entry containing information applicable to a particular parameter. | |
| NUM upsParameterLineIndex_third | 1.3.6.1.4.1.818.1.1.13.10.11.1.1 | PositiveInteger32 | not-accessible | The parameter line identifier. |
| I32 upsParameterValue_third | 1.3.6.1.4.1.818.1.1.13.10.11.1.2 | Integer32 | read-write | The parameter value in numerical format. |
| NUM upsStatus_third | 1.3.6.1.4.1.818.1.1.13.10.12 | NonNegativeInteger32 | read-only | The global UPS status is returned. Every bit reflects a specific status condition. Unused bits returns as 0. The status value can also be found on other commands. The value SNMP-NOSUCHNAME means 'invalid status' or 'status value non available'. Status 1 0001h upsStatusEcomodeIsOn 2 0002h upsStatusBatteryIsCharging 4 0004h upsStatusBatteryIsDischarging 8 0008h upsStatusAlarmIsActive 16 0010h upsStatusRectifierIsOn 32 0020h upsStatusLowBattery 64 0040h upsStatusOnBypass 128 0080h upsStatusMainsBypassOK 256 0100h upsStatusMainsRectifierOK 512 0200h upsStatusDetourIsOn 1024 0400h upsStatusAcousticAlarmIsOn 2048 0800h - (not used.) 4096 1000h upsStatusInverterIsOn 8192 2000h upsStatusNotInParallel (Q1 open) 16384 4000h upsStatusResetLoadOff 32768 8000h upsStatusLoadOff |
| NUM upsMainsStatisticsMBfail_third | 1.3.6.1.4.1.818.1.1.13.10.13 | NonNegativeInteger32 | read-only | Count of main bypass failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsMRfail_third | 1.3.6.1.4.1.818.1.1.13.10.14 | NonNegativeInteger32 | read-only | Count of mains rectifier failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsB2_third | 1.3.6.1.4.1.818.1.1.13.10.15 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (0..2 ms), during the last 7 days. |
| NUM upsMainsStatisticsB5_third | 1.3.6.1.4.1.818.1.1.13.10.16 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (2..5 ms), during the last 7 days. |
| NUM upsMainsStatisticsB10_third | 1.3.6.1.4.1.818.1.1.13.10.17 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (5..10 ms), during the last 7 days. |
| NUM upsMainsStatisticsB200_third | 1.3.6.1.4.1.818.1.1.13.10.18 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (10..200 ms), during the last 7 days. |
| NUM upsMainsStatisticsBypRel_third | 1.3.6.1.4.1.818.1.1.13.10.19 | NonNegativeInteger32 | read-only | Bypass reliability degree [0..100%;255]. The value NOSUCHNAME means 'not available'. |
| NUM upsTime_third | 1.3.6.1.4.1.818.1.1.13.10.20 | NonNegativeInteger32 | read-write | The current timestamp (or real-time) of the UPS. For the format, see 'Timestamp' specifications. The write-command has to comply with the correct timestamp format expected by the UPS (counter value or real-time-clock value). Missing to doing so will result in a SNMP-thirdERROR, meaning 'command not supported'. It is possible to know which is the timestamp format supported by the UPS, by issuing a read-command or by reading events, which includes timestamps. |
| STR upsRequestPermission_third | 1.3.6.1.4.1.818.1.1.13.10.21 | DisplayString | write-only | An encrypted code is send to enable use of restricted write objects during a limited period of time. |
| I32 upsEventGetCode_third | 1.3.6.1.4.1.818.1.1.13.10.22 | Integer32 | write-only | The code which is used as starting point to downloading the events from the UPS event buffer. |
| TES upsEventSpinLock_third | 1.3.6.1.4.1.818.1.1.13.10.23 | TestAndIncr | read-write | A spin lock on the event subsystem. |
| TES upsParameterSpinLock_third | 1.3.6.1.4.1.818.1.1.13.10.24 | TestAndIncr | read-write | A spin lock on the parameters subsystem. |
| geUPSTraps_third | 1.3.6.1.4.1.818.1.1.13.11 | |||
| NTF upsAlarmBatteryBadTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.1 | One or more batteries have been determined to require replacement. | ||
| NTF upsAlarmOnBatteryTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.2 | An On Battery condition is restored. | ||
| NTF upsAlarmLowBatteryTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime. | ||
| NTF upsAlarmDepletedBatteryTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.4 | The UPS will be unable to sustain the present load when and if the utility power is lost) | ||
| NTF upsAlarmTempBadTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.5 | A temperature is out of tolerance. | ||
| NTF upsAlarmInputBadTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.6 | An input condition is out of tolerance. | ||
| NTF upsAlarmOutputBadTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.7 | An output condition (other than OutputOverload) is out of tolerance. | ||
| NTF upsAlarmOutputOverloadTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.8 | The output load exceeds the UPS output capacity. | ||
| NTF upsAlarmOnBypassTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.9 | The Bypass is presently engaged on the UPS. | ||
| NTF upsAlarmBypassBadTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.10 | The Bypass is out of tolerance. | ||
| NTF upsAlarmOutputOffAsRequestedTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.11 | The UPS has shutdown as requested, i.e., the output is off. | ||
| NTF upsAlarmUpsOffAsRequestedTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.12 | The entire UPS has shutdown as commanded. | ||
| NTF upsAlarmChargerFailedTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.13 | An uncorrected problem has been detected within the UPS charger subsystem. | ||
| NTF upsAlarmUpsOutputOffTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.14 | The output of the UPS is in the off state. | ||
| NTF upsAlarmUpsSystemOffTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.15 | The UPS system is in the off state. | ||
| NTF upsAlarmFanFailureTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.16 | The failure of one or more fans in the UPS has been detected. | ||
| NTF upsAlarmFuseFailureTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.17 | The failure of one or more fuses has been detected. | ||
| NTF upsAlarmGeneralFaultTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.18 | A general fault in the UPS has been detected. | ||
| NTF upsAlarmDiagnosticTestFailedTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.19 | The result of the last diagnostic test indicates a failure. | ||
| NTF upsAlarmCommunicationsLostTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.20 | A problem has been encountered in the communication between the agent and the UPS. | ||
| NTF upsAlarmAwaitingPowerTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.21 | The UPS output is off and the UPS is awaiting the return of the input power (*). | ||
| NTF upsAlarmShutdownPendingTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.22 | A upsShutdownAfterDelay countdown is underway. | ||
| NTF upsAlarmShutdownImminentTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | ||
| NTF upsAlarmTestInProgressTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | ||
| NTF upsAlarmReceptacleOffTrap_third | 1.3.6.1.4.1.818.1.1.13.11.0.25 | A receptacle has been switched off. | ||
| NTF upsAlarmBatteryBadRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.33 | A Battery bad condition is restored. | ||
| NTF upsAlarmOnBatteryRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.34 | The UPS is drawing power from mains again. | ||
| NTF upsAlarmLowBatteryRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.35 | A Low Battery condition is restored. | ||
| NTF upsAlarmDepletedBatteryRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.36 | A Depleted Battery condition is restored. | ||
| NTF upsAlarmTempBadRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.37 | A bad temperature condition is restored. | ||
| NTF upsAlarmInputBadRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.38 | An input bad condition is restored. | ||
| NTF upsAlarmOutputBadRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.39 | An output bad condition is restored. | ||
| NTF upsAlarmOutputOverloadRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.40 | An output overload condition is restored. | ||
| NTF upsAlarmOnBypassRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.41 | An On Bypass condition is restored. | ||
| NTF upsAlarmBypassBadRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.42 | A Bypass bad condition is restored. | ||
| NTF upsAlarmOutputOffAsRequestedRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.43 | A request shutdown has been restored. | ||
| NTF upsAlarmUpsOffAsRequestedRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.44 | A entire UPS command has been restored. | ||
| NTF upsAlarmChargerFailedRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.45 | A Charger Failer condition is restored. | ||
| NTF upsAlarmUpsOutputOn_third | 1.3.6.1.4.1.818.1.1.13.11.0.46 | The output of the UPS switched in the on state. | ||
| NTF upsAlarmUpsSystemOn_third | 1.3.6.1.4.1.818.1.1.13.11.0.47 | The UPS system is switched in the on state. | ||
| NTF upsAlarmFanFailureRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.48 | A Fan failure condition is restored. | ||
| NTF upsAlarmFuseFailureRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.49 | A Fuse failure condition is restored. | ||
| NTF upsAlarmGeneralFaultRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.50 | A general fault is restored. | ||
| NTF upsAlarmDiagnosticTestFailedRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.51 | A last diagnostic test indicates a failure is restored. | ||
| NTF upsAlarmCommunicationsLostRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.52 | A problem in the communication between the agent and the UPS is restored. | ||
| NTF upsAlarmAwaitingPowerRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.53 | A awaiting power condition is restored (*). | ||
| NTF upsAlarmShutdownPendingRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.54 | A upsShutdownAfterDelay countdown is restored. | ||
| NTF upsAlarmShutdownImminentRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.55 | A shutdown imminent condition is restored. | ||
| NTF upsAlarmTestInProgressRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.56 | The test is in progress is terminated. | ||
| NTF upsAlarmReceptacleOn_third | 1.3.6.1.4.1.818.1.1.13.11.0.57 | A receptacle has been switched on. | ||
| NTF upsAlarmValueLow_third | 1.3.6.1.4.1.818.1.1.13.11.0.129 | A measurement value reached a value below its low-level threshold. | ||
| NTF upsAlarmValueHigh_third | 1.3.6.1.4.1.818.1.1.13.11.0.130 | A measurement value reached a value higher than its high-level threshold. | ||
| NTF upsAlarmValueLowRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.133 | A ValueLow alarm condition is restored. | ||
| NTF upsAlarmValueHighRestored_third | 1.3.6.1.4.1.818.1.1.13.11.0.134 | A ValueHigh alarm condition is restored. | ||
| geFourthUPS | 1.3.6.1.4.1.818.1.1.14 | |||
| upsIdent_fourth | 1.3.6.1.4.1.818.1.1.14.1 | |||
| STR upsIdentManufacturer_fourth | 1.3.6.1.4.1.818.1.1.14.1.1 | DisplayString | read-only | The name of the UPS manufacturer.(*) |
| STR upsIdentModel_fourth | 1.3.6.1.4.1.818.1.1.14.1.2 | DisplayString | read-only | The UPS Model designation.(*) |
| STR upsIdentUPSSoftwareVersion_fourth | 1.3.6.1.4.1.818.1.1.14.1.3 | DisplayString | read-only | The UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.(*) |
| STR upsIdentAgentSoftwareVersion_fourth | 1.3.6.1.4.1.818.1.1.14.1.4 | DisplayString | read-only | The UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.(*) |
| STR upsIdentName_fourth | 1.3.6.1.4.1.818.1.1.14.1.5 | DisplayString | read-write | A string identifying the UPS. This object should be set by the administrator.(*) |
| STR upsIdentAttachedDevices_fourth | 1.3.6.1.4.1.818.1.1.14.1.6 | DisplayString | read-write | A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.(*) |
| STR upsIdentUPSSerialNumber_fourth | 1.3.6.1.4.1.818.1.1.14.1.7 | DisplayString | read-only | The UPS serial number |
| STR upsIdentComProtVersion_fourth | 1.3.6.1.4.1.818.1.1.14.1.8 | DisplayString | read-only | The IMV communication protocol version |
| NUM upsIdentOperatingTime_fourth | 1.3.6.1.4.1.818.1.1.14.1.9 | NonNegativeInteger32 | read-only | The present value of the operating time. total 'on' time since UPS manufactured |
| upsBattery_fourth | 1.3.6.1.4.1.818.1.1.14.2 | |||
| INT upsBatteryStatus_fourth | 1.3.6.1.4.1.818.1.1.14.2.1 | INTEGER | read-only | The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).(*) |
| NUM upsSecondsOnBattery_fourth | 1.3.6.1.4.1.818.1.1.14.2.2 | NonNegativeInteger32 | read-only | If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.(*) |
| NUM upsEstimatedMinutesRemaining_fourth | 1.3.6.1.4.1.818.1.1.14.2.3 | PositiveInteger32 | read-only | An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.(*) |
| I32 upsEstimatedChargeRemaining_fourth | 1.3.6.1.4.1.818.1.1.14.2.4 | Integer32 | read-only | An estimate of the battery charge remaining expressed as a percent of full charge.(*) |
| NUM upsBatteryVoltage_fourth | 1.3.6.1.4.1.818.1.1.14.2.5 | NonNegativeInteger32 | read-only | The magnitude of the present battery voltage.(*) |
| I32 upsBatteryCurrent_fourth | 1.3.6.1.4.1.818.1.1.14.2.6 | Integer32 | read-only | The present battery current.(*) |
| I32 upsBatteryTemperature_fourth | 1.3.6.1.4.1.818.1.1.14.2.7 | Integer32 | read-only | The ambient temperature at or near the UPS Battery casing.(*) |
| upsInput_fourth | 1.3.6.1.4.1.818.1.1.14.3 | |||
| C32 upsInputLineBads_fourth | 1.3.6.1.4.1.818.1.1.14.3.1 | Counter32 | read-only | A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.(*) |
| NUM upsInputNumLines_fourth | 1.3.6.1.4.1.818.1.1.14.3.2 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This variable indicates the number of rows in the input table.(*) |
| upsInputTable_fourth | 1.3.6.1.4.1.818.1.1.14.3.3 | not-accessible | A list of input table entries. The number of entries is given by the value of upsInputNumLines.(*) | |
| upsInputEntry_fourth | 1.3.6.1.4.1.818.1.1.14.3.3.1 | not-accessible | An entry containing information applicable to a particular input line.(*) | |
| NUM upsInputLineIndex_fourth | 1.3.6.1.4.1.818.1.1.14.3.3.1.1 | PositiveInteger32 | not-accessible | The input line identifier.(*) |
| NUM upsInputFrequency_fourth | 1.3.6.1.4.1.818.1.1.14.3.3.1.2 | NonNegativeInteger32 | read-only | The present input frequency.(*) |
| NUM upsInputVoltage_fourth | 1.3.6.1.4.1.818.1.1.14.3.3.1.3 | NonNegativeInteger32 | read-only | The magnitude of the present input voltage.(*) |
| NUM upsInputCurrent_fourth | 1.3.6.1.4.1.818.1.1.14.3.3.1.4 | NonNegativeInteger32 | read-only | The magnitude of the present input current.(*) |
| NUM upsInputTruePower_fourth | 1.3.6.1.4.1.818.1.1.14.3.3.1.5 | NonNegativeInteger32 | read-only | The magnitude of the present input true power.(*) |
| NUM upsInputVoltageMin_fourth | 1.3.6.1.4.1.818.1.1.14.3.3.1.6 | NonNegativeInteger32 | read-only | The lowest magnitude of the input voltage since last read out. |
| NUM upsInputVoltageMax_fourth | 1.3.6.1.4.1.818.1.1.14.3.3.1.7 | NonNegativeInteger32 | read-only | The highest magnitude of the input voltage since last read out. |
| upsOutput_fourth | 1.3.6.1.4.1.818.1.1.14.4 | |||
| INT upsOutputSource_fourth | 1.3.6.1.4.1.818.1.1.14.4.1 | INTEGER | read-only | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.(*) |
| NUM upsOutputFrequency_fourth | 1.3.6.1.4.1.818.1.1.14.4.2 | NonNegativeInteger32 | read-only | The present output frequency.(*) |
| NUM upsOutputNumLines_fourth | 1.3.6.1.4.1.818.1.1.14.4.3 | NonNegativeInteger32 | read-only | The number of output lines utilized in this device. This variable indicates the number of rows in the output table.(*) |
| upsOutputTable_fourth | 1.3.6.1.4.1.818.1.1.14.4.4 | not-accessible | A list of output table entries. The number of entries is given by the value of upsOutputNumLines.(*) | |
| upsOutputEntry_fourth | 1.3.6.1.4.1.818.1.1.14.4.4.1 | not-accessible | An entry containing information applicable to a particular output line.(*) | |
| NUM upsOutputLineIndex_fourth | 1.3.6.1.4.1.818.1.1.14.4.4.1.1 | PositiveInteger32 | not-accessible | The output line identifier.(*) |
| NUM upsOutputVoltage_fourth | 1.3.6.1.4.1.818.1.1.14.4.4.1.2 | NonNegativeInteger32 | read-only | The present output voltage.(*) |
| NUM upsOutputCurrent_fourth | 1.3.6.1.4.1.818.1.1.14.4.4.1.3 | NonNegativeInteger32 | read-only | The present output current.(*) |
| NUM upsOutputPower_fourth | 1.3.6.1.4.1.818.1.1.14.4.4.1.4 | NonNegativeInteger32 | read-only | The present output true power.(*) |
| I32 upsOutputPercentLoad_fourth | 1.3.6.1.4.1.818.1.1.14.4.4.1.5 | Integer32 | read-only | The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.(*) |
| upsBypass_fourth | 1.3.6.1.4.1.818.1.1.14.5 | |||
| NUM upsBypassFrequency_fourth | 1.3.6.1.4.1.818.1.1.14.5.1 | NonNegativeInteger32 | read-only | The present bypass frequency.(*) |
| NUM upsBypassNumLines_fourth | 1.3.6.1.4.1.818.1.1.14.5.2 | NonNegativeInteger32 | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.(*) |
| upsBypassTable_fourth | 1.3.6.1.4.1.818.1.1.14.5.3 | not-accessible | A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.(*) | |
| upsBypassEntry_fourth | 1.3.6.1.4.1.818.1.1.14.5.3.1 | not-accessible | An entry containing information applicable to a particular bypass input.(*) | |
| NUM upsBypassLineIndex_fourth | 1.3.6.1.4.1.818.1.1.14.5.3.1.1 | PositiveInteger32 | not-accessible | The bypass line identifier.(*) |
| NUM upsBypassVoltage_fourth | 1.3.6.1.4.1.818.1.1.14.5.3.1.2 | NonNegativeInteger32 | read-only | The present bypass voltage.(*) |
| NUM upsBypassCurrent_fourth | 1.3.6.1.4.1.818.1.1.14.5.3.1.3 | NonNegativeInteger32 | read-only | The present bypass current.(*) |
| NUM upsBypassPower_fourth | 1.3.6.1.4.1.818.1.1.14.5.3.1.4 | NonNegativeInteger32 | read-only | The present true power conveyed by the bypass.(*) |
| upsAlarm_fourth | 1.3.6.1.4.1.818.1.1.14.6 | |||
| G32 upsAlarmsPresent_fourth | 1.3.6.1.4.1.818.1.1.14.6.1 | Gauge32 | read-only | The present number of active alarm conditions.(*) |
| upsAlarmTable_fourth | 1.3.6.1.4.1.818.1.1.14.6.2 | not-accessible | A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent.(*) | |
| upsAlarmEntry_fourth | 1.3.6.1.4.1.818.1.1.14.6.2.1 | not-accessible | An entry containing information applicable to a particular alarm.(*) | |
| NUM upsAlarmId_fourth | 1.3.6.1.4.1.818.1.1.14.6.2.1.1 | PositiveInteger32 | not-accessible | A unique identifier for an alarm condition. This value must remain constant.(*) |
| OID upsAlarmDescr_fourth | 1.3.6.1.4.1.818.1.1.14.6.2.1.2 | AutonomousType | read-only | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.(*) |
| TIM upsAlarmTime_fourth | 1.3.6.1.4.1.818.1.1.14.6.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.(*) |
| upsWellKnownAlarms_fourth | 1.3.6.1.4.1.818.1.1.14.6.3 | |||
| upsAlarmBatteryBad_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.1 | One or more batteries have been determined to require replacement.(*) | ||
| upsAlarmOnBattery_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.2 | The UPS is drawing power from the batteries.(*) | ||
| upsAlarmLowBattery_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime.(*) | ||
| upsAlarmDepletedBattery_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.4 | The UPS will be unable to sustain the present load when and if the utility power is lost.(*) | ||
| upsAlarmTempBad_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.5 | A temperature is out of tolerance.(*) | ||
| upsAlarmInputBad_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.6 | An input condition is out of tolerance.(*) | ||
| upsAlarmOutputBad_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.7 | An output condition (other than OutputOverload) is out of tolerance.(*) | ||
| upsAlarmOutputOverload_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.8 | The output load exceeds the UPS output capacity.(*) | ||
| upsAlarmOnBypass_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.9 | The Bypass is presently engaged on the UPS.(*) | ||
| upsAlarmBypassBad_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.10 | The Bypass is out of tolerance.(*) | ||
| upsAlarmOutputOffAsRequested_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.11 | The UPS has shutdown as requested, i.e., the output is off.(*) | ||
| upsAlarmUpsOffAsRequested_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.12 | The entire UPS has shutdown as commanded.(*) | ||
| upsAlarmChargerFailed_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.13 | An uncorrected problem has been detected within the UPS charger subsystem.(*) | ||
| upsAlarmUpsOutputOff_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.14 | The output of the UPS is in the off state.(*) | ||
| upsAlarmUpsSystemOff_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.15 | The UPS system is in the off state.(*) | ||
| upsAlarmFanFailure_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.16 | The failure of one or more fans in the UPS has been detected.(*) | ||
| upsAlarmFuseFailure_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.17 | The failure of one or more fuses has been detected.(*) | ||
| upsAlarmGeneralFault_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.18 | A general fault in the UPS has been detected.(*) | ||
| upsAlarmDiagnosticTestFailed_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.19 | The result of the last diagnostic test indicates a failure.(*) | ||
| upsAlarmCommunicationsLost_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.20 | A problem has been encountered in the communications between the agent and the UPS.(*) | ||
| upsAlarmAwaitingPower_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.21 | The UPS output is off and the UPS is awaiting the return of input power.(*) | ||
| upsAlarmShutdownPending_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.22 | A upsShutdownAfterDelay countdown is underway.(*) | ||
| upsAlarmShutdownImminent_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.(*) | ||
| upsAlarmTestInProgress_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY.(*) | ||
| upsAlarmReceptacleOff_fourth | 1.3.6.1.4.1.818.1.1.14.6.3.25 | The receptacle are switch off | ||
| NUM upsAlarmMaskA_fourth | 1.3.6.1.4.1.818.1.1.14.6.4 | NonNegativeInteger32 | read-only | Specifies which alarm can be handled by the UPS. The 'Mask' parameter is a Long Integer32. The meaning of every bit is the same as for the 'upsAlarmGroupA' command. A bit having value=1 indicates that the corresponding alarm is handled by the UPS. |
| upsTest_fourth | 1.3.6.1.4.1.818.1.1.14.7 | |||
| OID upsTestId_fourth | 1.3.6.1.4.1.818.1.1.14.7.1 | OBJECT IDENTIFIER | read-write | The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned.(*) |
| TES upsTestSpinLock_fourth | 1.3.6.1.4.1.818.1.1.14.7.2 | TestAndIncr | read-write | A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try-again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock-value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock-value, upsTestId = requested-test) if (error-index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try-again } if (error-index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by polling upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock-value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1.(*) |
| INT upsTestResultsSummary_fourth | 1.3.6.1.4.1.818.1.1.14.7.3 | INTEGER | read-only | The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.(*) |
| STR upsTestResultsDetail_fourth | 1.3.6.1.4.1.818.1.1.14.7.4 | DisplayString | read-only | Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned.(*) |
| TIM upsTestStartTime_fourth | 1.3.6.1.4.1.818.1.1.14.7.5 | TimeStamp | read-only | The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0.(*) |
| NUM upsTestElapsedTime_fourth | 1.3.6.1.4.1.818.1.1.14.7.6 | TimeInterval | read-only | The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0.(*) |
| upsWellKnownTests_fourth | 1.3.6.1.4.1.818.1.1.14.7.7 | |||
| upsTestNoTestsInitiated_fourth | 1.3.6.1.4.1.818.1.1.14.7.7.1 | No tests have been initiated and no test is in progress.(*) | ||
| upsTestAbortTestInProgress_fourth | 1.3.6.1.4.1.818.1.1.14.7.7.2 | The test in progress is to be aborted / the test in progress was aborted.(*) | ||
| upsTestGeneralSystemsTest_fourth | 1.3.6.1.4.1.818.1.1.14.7.7.3 | The manufacturer's standard test of UPS device systems.(*) | ||
| upsTestQuickBatteryTest_fourth | 1.3.6.1.4.1.818.1.1.14.7.7.4 | A test that is sufficient to determine if the battery needs replacement.(*) | ||
| upsTestDeepBatteryCalibration_fourth | 1.3.6.1.4.1.818.1.1.14.7.7.5 | The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load.(*) | ||
| upsControl_fourth | 1.3.6.1.4.1.818.1.1.14.8 | |||
| INT upsShutdownType_fourth | 1.3.6.1.4.1.818.1.1.14.8.1 | INTEGER | read-write | This object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.(*) |
| I32 upsShutdownAfterDelay_fourth | 1.3.6.1.4.1.818.1.1.14.8.2 | Integer32 | read-write | Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.(*) |
| I32 upsStartupAfterDelay_fourth | 1.3.6.1.4.1.818.1.1.14.8.3 | Integer32 | read-write | Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.(*) |
| I32 upsRebootWithDuration_fourth | 1.3.6.1.4.1.818.1.1.14.8.4 | Integer32 | read-write | Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.(*) |
| INT upsAutoRestart_fourth | 1.3.6.1.4.1.818.1.1.14.8.5 | INTEGER | read-write | Setting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutdownAfterDelay or an internal battery depleted condition. Setting this object to 'off' will prevent the UPS system from restarting after a shutdown until an operator manually or remotely explicitly restarts it. If the UPS is in a startup or reboot countdown, then the UPS will not restart until that delay has been satisfied.(*) |
| NUM upsReceptaclesNum_fourth | 1.3.6.1.4.1.818.1.1.14.8.6 | NonNegativeInteger32 | read-only | The number of receptacles utilized in this device. This entry indicates the number of rows in the receptacle table. |
| upsReceptacleTable_fourth | 1.3.6.1.4.1.818.1.1.14.8.7 | not-accessible | A list of receptacle table entries. The number of entries is given by the value of upsReceptacleNum. | |
| upsReceptacleEntry_fourth | 1.3.6.1.4.1.818.1.1.14.8.7.1 | not-accessible | An entry containing information applicable to a particular receptacle. | |
| NUM upsReceptacleLineIndex_fourth | 1.3.6.1.4.1.818.1.1.14.8.7.1.1 | PositiveInteger32 | not-accessible | The receptacle line identifier. |
| INT upsReceptacleOnOff_fourth | 1.3.6.1.4.1.818.1.1.14.8.7.1.2 | INTEGER | read-write | The present state of the receptacle. Setting this object to 'on' will cause the receptacle to be turned on. Setting this object to 'off' will turn the receptacle off. If the receptacle is already in the desired state nothing will happen. After an autorestart (see upsAutoRestart) the receptacle will be on. |
| INT upsUPSMode_fourth | 1.3.6.1.4.1.818.1.1.14.8.8 | INTEGER | read-write | The operation mode off the UPS. Off-line indicates a mode in which the input power is transferred to the output directly or via a step-up or step-down transformer. On-line mode indicates a mode in which the output power is regenerated through some convertor. the operating mode of the UPS may be fixed, or may be selectable (e.g. an on-line UPS with ecomode) |
| INT upsRectifierOnOff_fourth | 1.3.6.1.4.1.818.1.1.14.8.9 | INTEGER | read-write | The present state of the rectifier. Setting this object to 'on' will cause the rectifier to be turned on. Setting this object to 'off' will turn the rectifier off. If the rectifier is already in the desired state nothing will happen. |
| INT upsBatteryChargeMethod_fourth | 1.3.6.1.4.1.818.1.1.14.8.10 | INTEGER | read-write | The present state of the charge method. Setting this object to 'Normal charge' will cause the battery to be charged using the normal method. Setting this object to 'Boost charge' will charge the battery in boost mode. If the charge method is already in the desired state nothing will happen. |
| INT upsInverterOnOff_fourth | 1.3.6.1.4.1.818.1.1.14.8.11 | INTEGER | read-write | The present state of the inverter. Setting this object to 'on' will cause the inverter to be turned on. Setting this object to 'off' will turn the inverter off. If the inverter is already in the desired state nothing will happen. |
| INT upsBypassOnOff_fourth | 1.3.6.1.4.1.818.1.1.14.8.12 | INTEGER | read-write | The present state of the bypass. Setting this object to 'on' will cause the bypass to be activated. Setting this object to 'off' will deactivate the bypass. If the UPS is already in the desired state nothing will happen. |
| INT upsLoadSource_fourth | 1.3.6.1.4.1.818.1.1.14.8.13 | INTEGER | read-write | The present source of the load. Setting this object to 'On bypass' will cause the load to be supplied by the bypass. Setting this object to 'On inverter' will cause the load to be supplied by the inverter. If the load is already supplied by the desired source nothing will happen. |
| upsConfig_fourth | 1.3.6.1.4.1.818.1.1.14.9 | |||
| NUM upsConfigInputVoltage_fourth | 1.3.6.1.4.1.818.1.1.14.9.1 | NonNegativeInteger32 | read-write | The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigInputFreq_fourth | 1.3.6.1.4.1.818.1.1.14.9.2 | NonNegativeInteger32 | read-write | The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVoltage_fourth | 1.3.6.1.4.1.818.1.1.14.9.3 | NonNegativeInteger32 | read-write | The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputFreq_fourth | 1.3.6.1.4.1.818.1.1.14.9.4 | NonNegativeInteger32 | read-write | The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVA_fourth | 1.3.6.1.4.1.818.1.1.14.9.5 | NonNegativeInteger32 | read-only | The magnitude of the nominal Volt-Amp rating.(*) |
| NUM upsConfigOutputPower_fourth | 1.3.6.1.4.1.818.1.1.14.9.6 | NonNegativeInteger32 | read-only | The magnitude of the nominal true power rating.(*) |
| NUM upsConfigLowBattTime_fourth | 1.3.6.1.4.1.818.1.1.14.9.7 | NonNegativeInteger32 | read-write | The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.(*) |
| INT upsConfigAudibleStatus_fourth | 1.3.6.1.4.1.818.1.1.14.9.8 | INTEGER | read-write | The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.(*) |
| NUM upsConfigLowVoltageTransferPoint_fourth | 1.3.6.1.4.1.818.1.1.14.9.9 | NonNegativeInteger32 | read-write | The minimum input line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigHighVoltageTransferPoint_fourth | 1.3.6.1.4.1.818.1.1.14.9.10 | NonNegativeInteger32 | read-write | The maximum line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigBatteryCapacity_fourth | 1.3.6.1.4.1.818.1.1.14.9.11 | NonNegativeInteger32 | read-write | The installed battery capacity. This value is the 'factory'-value, not the value after calibration. |
| NUM upsConfigBatteryChargeCurrent_fourth | 1.3.6.1.4.1.818.1.1.14.9.12 | NonNegativeInteger32 | read-write | The maximum battery charge current, including external chargers. |
| INT upsConfigNoLoadShutdown_fourth | 1.3.6.1.4.1.818.1.1.14.9.13 | INTEGER | read-write | Dis- or enable 'no load' shutdown from the contact interface. |
| NUM upsConfigStartDelay_fourth | 1.3.6.1.4.1.818.1.1.14.9.14 | PositiveInteger32 | read-write | Minimum required autonomy time before the UPS may perform an autorestart. |
| upsGetSet_fourth | 1.3.6.1.4.1.818.1.1.14.10 | |||
| NUM upsEventGetNext_fourth | 1.3.6.1.4.1.818.1.1.14.10.1 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventSetStartingTimeStamp will be used as the start value of the table with the lowest index number. |
| NUM upsEventGetPrevious_fourth | 1.3.6.1.4.1.818.1.1.14.10.2 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventLastTime will be used as the last value of the table with the highest index number. Returns SNMP-NOSUCHNAME for UPSs that don't support this command. |
| NUM upsEventSetStartingTimeStamp_fourth | 1.3.6.1.4.1.818.1.1.14.10.3 | NonNegativeInteger32 | read-write | The timestamp which is used as starting point for downloading events from the UPS event buffer |
| NUM upsEventRetreiveCurrentTimeStamp_fourth | 1.3.6.1.4.1.818.1.1.14.10.4 | NonNegativeInteger32 | read-only | The current timestamp is retreived from the UPS |
| NUM upsEventTableSize_fourth | 1.3.6.1.4.1.818.1.1.14.10.5 | NonNegativeInteger32 | read-only | The number of entries in the event table. This object indicates the number of rows in the event table. |
| upsEventTable_fourth | 1.3.6.1.4.1.818.1.1.14.10.6 | not-accessible | A list of event table entries. The number of entries is always 10, and the value of upsEventTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..10)): PDU-SET upsSetStartingTimeStamp PDU-SET upsEventGetNext PDU-GET upsEventTableSize PDU-GET upsEventCode,upsEventStatus,upsEventTime 1 PDU-GET upsEventCode,upsEventStatus,upsEventTime 2 .. PDU-GET upsEventCode,upsEventStatus,upsEventTime The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsEventTableSize. | |
| upsEventEntry_fourth | 1.3.6.1.4.1.818.1.1.14.10.6.1 | not-accessible | An entry containing information applicable to a particular event. | |
| NUM upsEventLineIndex_fourth | 1.3.6.1.4.1.818.1.1.14.10.6.1.1 | PositiveInteger32 | not-accessible | The event line identifier. |
| NUM upsEventCode_fourth | 1.3.6.1.4.1.818.1.1.14.10.6.1.2 | NonNegativeInteger32 | read-only | The event code in numerical format. |
| NUM upsEventStatus_fourth | 1.3.6.1.4.1.818.1.1.14.10.6.1.3 | NonNegativeInteger32 | read-only | The status of the UPS at the moment that the event was generated. The format is specified at the 'upsStatus' command. If the UPS is not able to deliver status information, then SNMP-NOSUCHNAME is returned. |
| NUM upsEventTime_fourth | 1.3.6.1.4.1.818.1.1.14.10.6.1.4 | NonNegativeInteger32 | read-only | The timestamp of the moment the event was generated. |
| NUM upsParametersRead_fourth | 1.3.6.1.4.1.818.1.1.14.10.7 | PositiveInteger32 | read-write | The number of parameters to retreive from the UPS. When this object is set the ParameterTable will be filled with the requested number of entries. The value upsParametersStartAddress will be used as the start value of the table with the lowest index number. |
| NUM upsParametersWrite_fourth | 1.3.6.1.4.1.818.1.1.14.10.8 | PositiveInteger32 | read-write | The number of parameters to write to the UPS. When this object is set the ParameterTable will be send to the ups. The value upsParametersStartAddress will be used for the first value of the table with the lowest index number. |
| NUM upsParametersStartAddress_fourth | 1.3.6.1.4.1.818.1.1.14.10.9 | NonNegativeInteger32 | read-write | The address which is used as starting point for downloading parameters from the UPS |
| NUM upsParameterTableSize_fourth | 1.3.6.1.4.1.818.1.1.14.10.10 | NonNegativeInteger32 | read-only | The number of entries in the parameter table. This object indicates the number of rows in the parameter table. |
| upsParameterTable_fourth | 1.3.6.1.4.1.818.1.1.14.10.11 | not-accessible | A list of parameter entries. The number of entries is always 16, and the value of upsParameterTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..16)): Read sequence: PDU-SET upsSetStartingAddress PDU-SET upsParametersRead PDU-GET upsParameterTableSize PDU-GET upsParameterValue 1 PDU-GET upsParameterValue 2 .. PDU-GET upsParameterValue The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsParameterTableSize. Write sequence: PDU-SET upsSetStartingAddress PDU-SET upsParameterValue 1 PDU-SET upsParameterValue 2 .. PDU-SET upsParameterValue PDU-SET upsParametersWrite | |
| upsParameterEntry_fourth | 1.3.6.1.4.1.818.1.1.14.10.11.1 | not-accessible | An entry containing information applicable to a particular parameter. | |
| NUM upsParameterLineIndex_fourth | 1.3.6.1.4.1.818.1.1.14.10.11.1.1 | PositiveInteger32 | not-accessible | The parameter line identifier. |
| I32 upsParameterValue_fourth | 1.3.6.1.4.1.818.1.1.14.10.11.1.2 | Integer32 | read-write | The parameter value in numerical format. |
| NUM upsStatus_fourth | 1.3.6.1.4.1.818.1.1.14.10.12 | NonNegativeInteger32 | read-only | The global UPS status is returned. Every bit reflects a specific status condition. Unused bits returns as 0. The status value can also be found on other commands. The value SNMP-NOSUCHNAME means 'invalid status' or 'status value non available'. Status 1 0001h upsStatusEcomodeIsOn 2 0002h upsStatusBatteryIsCharging 4 0004h upsStatusBatteryIsDischarging 8 0008h upsStatusAlarmIsActive 16 0010h upsStatusRectifierIsOn 32 0020h upsStatusLowBattery 64 0040h upsStatusOnBypass 128 0080h upsStatusMainsBypassOK 256 0100h upsStatusMainsRectifierOK 512 0200h upsStatusDetourIsOn 1024 0400h upsStatusAcousticAlarmIsOn 2048 0800h - (not used.) 4096 1000h upsStatusInverterIsOn 8192 2000h upsStatusNotInParallel (Q1 open) 16384 4000h upsStatusResetLoadOff 32768 8000h upsStatusLoadOff |
| NUM upsMainsStatisticsMBfail_fourth | 1.3.6.1.4.1.818.1.1.14.10.13 | NonNegativeInteger32 | read-only | Count of main bypass failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsMRfail_fourth | 1.3.6.1.4.1.818.1.1.14.10.14 | NonNegativeInteger32 | read-only | Count of mains rectifier failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsB2_fourth | 1.3.6.1.4.1.818.1.1.14.10.15 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (0..2 ms), during the last 7 days. |
| NUM upsMainsStatisticsB5_fourth | 1.3.6.1.4.1.818.1.1.14.10.16 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (2..5 ms), during the last 7 days. |
| NUM upsMainsStatisticsB10_fourth | 1.3.6.1.4.1.818.1.1.14.10.17 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (5..10 ms), during the last 7 days. |
| NUM upsMainsStatisticsB200_fourth | 1.3.6.1.4.1.818.1.1.14.10.18 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (10..200 ms), during the last 7 days. |
| NUM upsMainsStatisticsBypRel_fourth | 1.3.6.1.4.1.818.1.1.14.10.19 | NonNegativeInteger32 | read-only | Bypass reliability degree [0..100%;255]. The value NOSUCHNAME means 'not available'. |
| NUM upsTime_fourth | 1.3.6.1.4.1.818.1.1.14.10.20 | NonNegativeInteger32 | read-write | The current timestamp (or real-time) of the UPS. For the format, see 'Timestamp' specifications. The write-command has to comply with the correct timestamp format expected by the UPS (counter value or real-time-clock value). Missing to doing so will result in a SNMP-fourthERROR, meaning 'command not supported'. It is possible to know which is the timestamp format supported by the UPS, by issuing a read-command or by reading events, which includes timestamps. |
| STR upsRequestPermission_fourth | 1.3.6.1.4.1.818.1.1.14.10.21 | DisplayString | write-only | An encrypted code is send to enable use of restricted write objects during a limited period of time. |
| I32 upsEventGetCode_fourth | 1.3.6.1.4.1.818.1.1.14.10.22 | Integer32 | write-only | The code which is used as starting point to downloading the events from the UPS event buffer. |
| TES upsEventSpinLock_fourth | 1.3.6.1.4.1.818.1.1.14.10.23 | TestAndIncr | read-write | A spin lock on the event subsystem. |
| TES upsParameterSpinLock_fourth | 1.3.6.1.4.1.818.1.1.14.10.24 | TestAndIncr | read-write | A spin lock on the parameters subsystem. |
| geUPSTraps_fourth | 1.3.6.1.4.1.818.1.1.14.11 | |||
| NTF upsAlarmBatteryBadTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.1 | One or more batteries have been determined to require replacement. | ||
| NTF upsAlarmOnBatteryTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.2 | An On Battery condition is restored. | ||
| NTF upsAlarmLowBatteryTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime. | ||
| NTF upsAlarmDepletedBatteryTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.4 | The UPS will be unable to sustain the present load when and if the utility power is lost) | ||
| NTF upsAlarmTempBadTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.5 | A temperature is out of tolerance. | ||
| NTF upsAlarmInputBadTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.6 | An input condition is out of tolerance. | ||
| NTF upsAlarmOutputBadTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.7 | An output condition (other than OutputOverload) is out of tolerance. | ||
| NTF upsAlarmOutputOverloadTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.8 | The output load exceeds the UPS output capacity. | ||
| NTF upsAlarmOnBypassTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.9 | The Bypass is presently engaged on the UPS. | ||
| NTF upsAlarmBypassBadTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.10 | The Bypass is out of tolerance. | ||
| NTF upsAlarmOutputOffAsRequestedTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.11 | The UPS has shutdown as requested, i.e., the output is off. | ||
| NTF upsAlarmUpsOffAsRequestedTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.12 | The entire UPS has shutdown as commanded. | ||
| NTF upsAlarmChargerFailedTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.13 | An uncorrected problem has been detected within the UPS charger subsystem. | ||
| NTF upsAlarmUpsOutputOffTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.14 | The output of the UPS is in the off state. | ||
| NTF upsAlarmUpsSystemOffTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.15 | The UPS system is in the off state. | ||
| NTF upsAlarmFanFailureTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.16 | The failure of one or more fans in the UPS has been detected. | ||
| NTF upsAlarmFuseFailureTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.17 | The failure of one or more fuses has been detected. | ||
| NTF upsAlarmGeneralFaultTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.18 | A general fault in the UPS has been detected. | ||
| NTF upsAlarmDiagnosticTestFailedTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.19 | The result of the last diagnostic test indicates a failure. | ||
| NTF upsAlarmCommunicationsLostTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.20 | A problem has been encountered in the communication between the agent and the UPS. | ||
| NTF upsAlarmAwaitingPowerTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.21 | The UPS output is off and the UPS is awaiting the return of the input power (*). | ||
| NTF upsAlarmShutdownPendingTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.22 | A upsShutdownAfterDelay countdown is underway. | ||
| NTF upsAlarmShutdownImminentTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | ||
| NTF upsAlarmTestInProgressTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | ||
| NTF upsAlarmReceptacleOffTrap_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.25 | A receptacle has been switched off. | ||
| NTF upsAlarmBatteryBadRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.33 | A Battery bad condition is restored. | ||
| NTF upsAlarmOnBatteryRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.34 | The UPS is drawing power from mains again. | ||
| NTF upsAlarmLowBatteryRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.35 | A Low Battery condition is restored. | ||
| NTF upsAlarmDepletedBatteryRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.36 | A Depleted Battery condition is restored. | ||
| NTF upsAlarmTempBadRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.37 | A bad temperature condition is restored. | ||
| NTF upsAlarmInputBadRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.38 | An input bad condition is restored. | ||
| NTF upsAlarmOutputBadRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.39 | An output bad condition is restored. | ||
| NTF upsAlarmOutputOverloadRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.40 | An output overload condition is restored. | ||
| NTF upsAlarmOnBypassRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.41 | An On Bypass condition is restored. | ||
| NTF upsAlarmBypassBadRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.42 | A Bypass bad condition is restored. | ||
| NTF upsAlarmOutputOffAsRequestedRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.43 | A request shutdown has been restored. | ||
| NTF upsAlarmUpsOffAsRequestedRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.44 | A entire UPS command has been restored. | ||
| NTF upsAlarmChargerFailedRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.45 | A Charger Failer condition is restored. | ||
| NTF upsAlarmUpsOutputOn_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.46 | The output of the UPS switched in the on state. | ||
| NTF upsAlarmUpsSystemOn_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.47 | The UPS system is switched in the on state. | ||
| NTF upsAlarmFanFailureRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.48 | A Fan failure condition is restored. | ||
| NTF upsAlarmFuseFailureRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.49 | A Fuse failure condition is restored. | ||
| NTF upsAlarmGeneralFaultRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.50 | A general fault is restored. | ||
| NTF upsAlarmDiagnosticTestFailedRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.51 | A last diagnostic test indicates a failure is restored. | ||
| NTF upsAlarmCommunicationsLostRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.52 | A problem in the communication between the agent and the UPS is restored. | ||
| NTF upsAlarmAwaitingPowerRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.53 | A awaiting power condition is restored (*). | ||
| NTF upsAlarmShutdownPendingRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.54 | A upsShutdownAfterDelay countdown is restored. | ||
| NTF upsAlarmShutdownImminentRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.55 | A shutdown imminent condition is restored. | ||
| NTF upsAlarmTestInProgressRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.56 | The test is in progress is terminated. | ||
| NTF upsAlarmReceptacleOn_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.57 | A receptacle has been switched on. | ||
| NTF upsAlarmValueLow_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.129 | A measurement value reached a value below its low-level threshold. | ||
| NTF upsAlarmValueHigh_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.130 | A measurement value reached a value higher than its high-level threshold. | ||
| NTF upsAlarmValueLowRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.133 | A ValueLow alarm condition is restored. | ||
| NTF upsAlarmValueHighRestored_fourth | 1.3.6.1.4.1.818.1.1.14.11.0.134 | A ValueHigh alarm condition is restored. | ||
| geFifthUPS | 1.3.6.1.4.1.818.1.1.15 | |||
| upsIdent_fifth | 1.3.6.1.4.1.818.1.1.15.1 | |||
| STR upsIdentManufacturer_fifth | 1.3.6.1.4.1.818.1.1.15.1.1 | DisplayString | read-only | The name of the UPS manufacturer.(*) |
| STR upsIdentModel_fifth | 1.3.6.1.4.1.818.1.1.15.1.2 | DisplayString | read-only | The UPS Model designation.(*) |
| STR upsIdentUPSSoftwareVersion_fifth | 1.3.6.1.4.1.818.1.1.15.1.3 | DisplayString | read-only | The UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.(*) |
| STR upsIdentAgentSoftwareVersion_fifth | 1.3.6.1.4.1.818.1.1.15.1.4 | DisplayString | read-only | The UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.(*) |
| STR upsIdentName_fifth | 1.3.6.1.4.1.818.1.1.15.1.5 | DisplayString | read-write | A string identifying the UPS. This object should be set by the administrator.(*) |
| STR upsIdentAttachedDevices_fifth | 1.3.6.1.4.1.818.1.1.15.1.6 | DisplayString | read-write | A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.(*) |
| STR upsIdentUPSSerialNumber_fifth | 1.3.6.1.4.1.818.1.1.15.1.7 | DisplayString | read-only | The UPS serial number |
| STR upsIdentComProtVersion_fifth | 1.3.6.1.4.1.818.1.1.15.1.8 | DisplayString | read-only | The IMV communication protocol version |
| NUM upsIdentOperatingTime_fifth | 1.3.6.1.4.1.818.1.1.15.1.9 | NonNegativeInteger32 | read-only | The present value of the operating time. total 'on' time since UPS manufactured |
| upsBattery_fifth | 1.3.6.1.4.1.818.1.1.15.2 | |||
| INT upsBatteryStatus_fifth | 1.3.6.1.4.1.818.1.1.15.2.1 | INTEGER | read-only | The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).(*) |
| NUM upsSecondsOnBattery_fifth | 1.3.6.1.4.1.818.1.1.15.2.2 | NonNegativeInteger32 | read-only | If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.(*) |
| NUM upsEstimatedMinutesRemaining_fifth | 1.3.6.1.4.1.818.1.1.15.2.3 | PositiveInteger32 | read-only | An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.(*) |
| I32 upsEstimatedChargeRemaining_fifth | 1.3.6.1.4.1.818.1.1.15.2.4 | Integer32 | read-only | An estimate of the battery charge remaining expressed as a percent of full charge.(*) |
| NUM upsBatteryVoltage_fifth | 1.3.6.1.4.1.818.1.1.15.2.5 | NonNegativeInteger32 | read-only | The magnitude of the present battery voltage.(*) |
| I32 upsBatteryCurrent_fifth | 1.3.6.1.4.1.818.1.1.15.2.6 | Integer32 | read-only | The present battery current.(*) |
| I32 upsBatteryTemperature_fifth | 1.3.6.1.4.1.818.1.1.15.2.7 | Integer32 | read-only | The ambient temperature at or near the UPS Battery casing.(*) |
| upsInput_fifth | 1.3.6.1.4.1.818.1.1.15.3 | |||
| C32 upsInputLineBads_fifth | 1.3.6.1.4.1.818.1.1.15.3.1 | Counter32 | read-only | A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.(*) |
| NUM upsInputNumLines_fifth | 1.3.6.1.4.1.818.1.1.15.3.2 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This variable indicates the number of rows in the input table.(*) |
| upsInputTable_fifth | 1.3.6.1.4.1.818.1.1.15.3.3 | not-accessible | A list of input table entries. The number of entries is given by the value of upsInputNumLines.(*) | |
| upsInputEntry_fifth | 1.3.6.1.4.1.818.1.1.15.3.3.1 | not-accessible | An entry containing information applicable to a particular input line.(*) | |
| NUM upsInputLineIndex_fifth | 1.3.6.1.4.1.818.1.1.15.3.3.1.1 | PositiveInteger32 | not-accessible | The input line identifier.(*) |
| NUM upsInputFrequency_fifth | 1.3.6.1.4.1.818.1.1.15.3.3.1.2 | NonNegativeInteger32 | read-only | The present input frequency.(*) |
| NUM upsInputVoltage_fifth | 1.3.6.1.4.1.818.1.1.15.3.3.1.3 | NonNegativeInteger32 | read-only | The magnitude of the present input voltage.(*) |
| NUM upsInputCurrent_fifth | 1.3.6.1.4.1.818.1.1.15.3.3.1.4 | NonNegativeInteger32 | read-only | The magnitude of the present input current.(*) |
| NUM upsInputTruePower_fifth | 1.3.6.1.4.1.818.1.1.15.3.3.1.5 | NonNegativeInteger32 | read-only | The magnitude of the present input true power.(*) |
| NUM upsInputVoltageMin_fifth | 1.3.6.1.4.1.818.1.1.15.3.3.1.6 | NonNegativeInteger32 | read-only | The lowest magnitude of the input voltage since last read out. |
| NUM upsInputVoltageMax_fifth | 1.3.6.1.4.1.818.1.1.15.3.3.1.7 | NonNegativeInteger32 | read-only | The highest magnitude of the input voltage since last read out. |
| upsOutput_fifth | 1.3.6.1.4.1.818.1.1.15.4 | |||
| INT upsOutputSource_fifth | 1.3.6.1.4.1.818.1.1.15.4.1 | INTEGER | read-only | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.(*) |
| NUM upsOutputFrequency_fifth | 1.3.6.1.4.1.818.1.1.15.4.2 | NonNegativeInteger32 | read-only | The present output frequency.(*) |
| NUM upsOutputNumLines_fifth | 1.3.6.1.4.1.818.1.1.15.4.3 | NonNegativeInteger32 | read-only | The number of output lines utilized in this device. This variable indicates the number of rows in the output table.(*) |
| upsOutputTable_fifth | 1.3.6.1.4.1.818.1.1.15.4.4 | not-accessible | A list of output table entries. The number of entries is given by the value of upsOutputNumLines.(*) | |
| upsOutputEntry_fifth | 1.3.6.1.4.1.818.1.1.15.4.4.1 | not-accessible | An entry containing information applicable to a particular output line.(*) | |
| NUM upsOutputLineIndex_fifth | 1.3.6.1.4.1.818.1.1.15.4.4.1.1 | PositiveInteger32 | not-accessible | The output line identifier.(*) |
| NUM upsOutputVoltage_fifth | 1.3.6.1.4.1.818.1.1.15.4.4.1.2 | NonNegativeInteger32 | read-only | The present output voltage.(*) |
| NUM upsOutputCurrent_fifth | 1.3.6.1.4.1.818.1.1.15.4.4.1.3 | NonNegativeInteger32 | read-only | The present output current.(*) |
| NUM upsOutputPower_fifth | 1.3.6.1.4.1.818.1.1.15.4.4.1.4 | NonNegativeInteger32 | read-only | The present output true power.(*) |
| I32 upsOutputPercentLoad_fifth | 1.3.6.1.4.1.818.1.1.15.4.4.1.5 | Integer32 | read-only | The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.(*) |
| upsBypass_fifth | 1.3.6.1.4.1.818.1.1.15.5 | |||
| NUM upsBypassFrequency_fifth | 1.3.6.1.4.1.818.1.1.15.5.1 | NonNegativeInteger32 | read-only | The present bypass frequency.(*) |
| NUM upsBypassNumLines_fifth | 1.3.6.1.4.1.818.1.1.15.5.2 | NonNegativeInteger32 | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.(*) |
| upsBypassTable_fifth | 1.3.6.1.4.1.818.1.1.15.5.3 | not-accessible | A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.(*) | |
| upsBypassEntry_fifth | 1.3.6.1.4.1.818.1.1.15.5.3.1 | not-accessible | An entry containing information applicable to a particular bypass input.(*) | |
| NUM upsBypassLineIndex_fifth | 1.3.6.1.4.1.818.1.1.15.5.3.1.1 | PositiveInteger32 | not-accessible | The bypass line identifier.(*) |
| NUM upsBypassVoltage_fifth | 1.3.6.1.4.1.818.1.1.15.5.3.1.2 | NonNegativeInteger32 | read-only | The present bypass voltage.(*) |
| NUM upsBypassCurrent_fifth | 1.3.6.1.4.1.818.1.1.15.5.3.1.3 | NonNegativeInteger32 | read-only | The present bypass current.(*) |
| NUM upsBypassPower_fifth | 1.3.6.1.4.1.818.1.1.15.5.3.1.4 | NonNegativeInteger32 | read-only | The present true power conveyed by the bypass.(*) |
| upsAlarm_fifth | 1.3.6.1.4.1.818.1.1.15.6 | |||
| G32 upsAlarmsPresent_fifth | 1.3.6.1.4.1.818.1.1.15.6.1 | Gauge32 | read-only | The present number of active alarm conditions.(*) |
| upsAlarmTable_fifth | 1.3.6.1.4.1.818.1.1.15.6.2 | not-accessible | A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent.(*) | |
| upsAlarmEntry_fifth | 1.3.6.1.4.1.818.1.1.15.6.2.1 | not-accessible | An entry containing information applicable to a particular alarm.(*) | |
| NUM upsAlarmId_fifth | 1.3.6.1.4.1.818.1.1.15.6.2.1.1 | PositiveInteger32 | not-accessible | A unique identifier for an alarm condition. This value must remain constant.(*) |
| OID upsAlarmDescr_fifth | 1.3.6.1.4.1.818.1.1.15.6.2.1.2 | AutonomousType | read-only | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.(*) |
| TIM upsAlarmTime_fifth | 1.3.6.1.4.1.818.1.1.15.6.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.(*) |
| upsWellKnownAlarms_fifth | 1.3.6.1.4.1.818.1.1.15.6.3 | |||
| upsAlarmBatteryBad_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.1 | One or more batteries have been determined to require replacement.(*) | ||
| upsAlarmOnBattery_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.2 | The UPS is drawing power from the batteries.(*) | ||
| upsAlarmLowBattery_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime.(*) | ||
| upsAlarmDepletedBattery_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.4 | The UPS will be unable to sustain the present load when and if the utility power is lost.(*) | ||
| upsAlarmTempBad_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.5 | A temperature is out of tolerance.(*) | ||
| upsAlarmInputBad_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.6 | An input condition is out of tolerance.(*) | ||
| upsAlarmOutputBad_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.7 | An output condition (other than OutputOverload) is out of tolerance.(*) | ||
| upsAlarmOutputOverload_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.8 | The output load exceeds the UPS output capacity.(*) | ||
| upsAlarmOnBypass_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.9 | The Bypass is presently engaged on the UPS.(*) | ||
| upsAlarmBypassBad_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.10 | The Bypass is out of tolerance.(*) | ||
| upsAlarmOutputOffAsRequested_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.11 | The UPS has shutdown as requested, i.e., the output is off.(*) | ||
| upsAlarmUpsOffAsRequested_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.12 | The entire UPS has shutdown as commanded.(*) | ||
| upsAlarmChargerFailed_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.13 | An uncorrected problem has been detected within the UPS charger subsystem.(*) | ||
| upsAlarmUpsOutputOff_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.14 | The output of the UPS is in the off state.(*) | ||
| upsAlarmUpsSystemOff_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.15 | The UPS system is in the off state.(*) | ||
| upsAlarmFanFailure_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.16 | The failure of one or more fans in the UPS has been detected.(*) | ||
| upsAlarmFuseFailure_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.17 | The failure of one or more fuses has been detected.(*) | ||
| upsAlarmGeneralFault_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.18 | A general fault in the UPS has been detected.(*) | ||
| upsAlarmDiagnosticTestFailed_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.19 | The result of the last diagnostic test indicates a failure.(*) | ||
| upsAlarmCommunicationsLost_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.20 | A problem has been encountered in the communications between the agent and the UPS.(*) | ||
| upsAlarmAwaitingPower_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.21 | The UPS output is off and the UPS is awaiting the return of input power.(*) | ||
| upsAlarmShutdownPending_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.22 | A upsShutdownAfterDelay countdown is underway.(*) | ||
| upsAlarmShutdownImminent_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.(*) | ||
| upsAlarmTestInProgress_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY.(*) | ||
| upsAlarmReceptacleOff_fifth | 1.3.6.1.4.1.818.1.1.15.6.3.25 | The receptacle are switch off | ||
| NUM upsAlarmMaskA_fifth | 1.3.6.1.4.1.818.1.1.15.6.4 | NonNegativeInteger32 | read-only | Specifies which alarm can be handled by the UPS. The 'Mask' parameter is a Long Integer32. The meaning of every bit is the same as for the 'upsAlarmGroupA' command. A bit having value=1 indicates that the corresponding alarm is handled by the UPS. |
| upsTest_fifth | 1.3.6.1.4.1.818.1.1.15.7 | |||
| OID upsTestId_fifth | 1.3.6.1.4.1.818.1.1.15.7.1 | OBJECT IDENTIFIER | read-write | The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned.(*) |
| TES upsTestSpinLock_fifth | 1.3.6.1.4.1.818.1.1.15.7.2 | TestAndIncr | read-write | A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try-again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock-value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock-value, upsTestId = requested-test) if (error-index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try-again } if (error-index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by polling upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock-value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1.(*) |
| INT upsTestResultsSummary_fifth | 1.3.6.1.4.1.818.1.1.15.7.3 | INTEGER | read-only | The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.(*) |
| STR upsTestResultsDetail_fifth | 1.3.6.1.4.1.818.1.1.15.7.4 | DisplayString | read-only | Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned.(*) |
| TIM upsTestStartTime_fifth | 1.3.6.1.4.1.818.1.1.15.7.5 | TimeStamp | read-only | The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0.(*) |
| NUM upsTestElapsedTime_fifth | 1.3.6.1.4.1.818.1.1.15.7.6 | TimeInterval | read-only | The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0.(*) |
| upsWellKnownTests_fifth | 1.3.6.1.4.1.818.1.1.15.7.7 | |||
| upsTestNoTestsInitiated_fifth | 1.3.6.1.4.1.818.1.1.15.7.7.1 | No tests have been initiated and no test is in progress.(*) | ||
| upsTestAbortTestInProgress_fifth | 1.3.6.1.4.1.818.1.1.15.7.7.2 | The test in progress is to be aborted / the test in progress was aborted.(*) | ||
| upsTestGeneralSystemsTest_fifth | 1.3.6.1.4.1.818.1.1.15.7.7.3 | The manufacturer's standard test of UPS device systems.(*) | ||
| upsTestQuickBatteryTest_fifth | 1.3.6.1.4.1.818.1.1.15.7.7.4 | A test that is sufficient to determine if the battery needs replacement.(*) | ||
| upsTestDeepBatteryCalibration_fifth | 1.3.6.1.4.1.818.1.1.15.7.7.5 | The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load.(*) | ||
| upsControl_fifth | 1.3.6.1.4.1.818.1.1.15.8 | |||
| INT upsShutdownType_fifth | 1.3.6.1.4.1.818.1.1.15.8.1 | INTEGER | read-write | This object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.(*) |
| I32 upsShutdownAfterDelay_fifth | 1.3.6.1.4.1.818.1.1.15.8.2 | Integer32 | read-write | Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.(*) |
| I32 upsStartupAfterDelay_fifth | 1.3.6.1.4.1.818.1.1.15.8.3 | Integer32 | read-write | Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.(*) |
| I32 upsRebootWithDuration_fifth | 1.3.6.1.4.1.818.1.1.15.8.4 | Integer32 | read-write | Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.(*) |
| INT upsAutoRestart_fifth | 1.3.6.1.4.1.818.1.1.15.8.5 | INTEGER | read-write | Setting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutdownAfterDelay or an internal battery depleted condition. Setting this object to 'off' will prevent the UPS system from restarting after a shutdown until an operator manually or remotely explicitly restarts it. If the UPS is in a startup or reboot countdown, then the UPS will not restart until that delay has been satisfied.(*) |
| NUM upsReceptaclesNum_fifth | 1.3.6.1.4.1.818.1.1.15.8.6 | NonNegativeInteger32 | read-only | The number of receptacles utilized in this device. This entry indicates the number of rows in the receptacle table. |
| upsReceptacleTable_fifth | 1.3.6.1.4.1.818.1.1.15.8.7 | not-accessible | A list of receptacle table entries. The number of entries is given by the value of upsReceptacleNum. | |
| upsReceptacleEntry_fifth | 1.3.6.1.4.1.818.1.1.15.8.7.1 | not-accessible | An entry containing information applicable to a particular receptacle. | |
| NUM upsReceptacleLineIndex_fifth | 1.3.6.1.4.1.818.1.1.15.8.7.1.1 | PositiveInteger32 | not-accessible | The receptacle line identifier. |
| INT upsReceptacleOnOff_fifth | 1.3.6.1.4.1.818.1.1.15.8.7.1.2 | INTEGER | read-write | The present state of the receptacle. Setting this object to 'on' will cause the receptacle to be turned on. Setting this object to 'off' will turn the receptacle off. If the receptacle is already in the desired state nothing will happen. After an autorestart (see upsAutoRestart) the receptacle will be on. |
| INT upsUPSMode_fifth | 1.3.6.1.4.1.818.1.1.15.8.8 | INTEGER | read-write | The operation mode off the UPS. Off-line indicates a mode in which the input power is transferred to the output directly or via a step-up or step-down transformer. On-line mode indicates a mode in which the output power is regenerated through some convertor. the operating mode of the UPS may be fixed, or may be selectable (e.g. an on-line UPS with ecomode) |
| INT upsRectifierOnOff_fifth | 1.3.6.1.4.1.818.1.1.15.8.9 | INTEGER | read-write | The present state of the rectifier. Setting this object to 'on' will cause the rectifier to be turned on. Setting this object to 'off' will turn the rectifier off. If the rectifier is already in the desired state nothing will happen. |
| INT upsBatteryChargeMethod_fifth | 1.3.6.1.4.1.818.1.1.15.8.10 | INTEGER | read-write | The present state of the charge method. Setting this object to 'Normal charge' will cause the battery to be charged using the normal method. Setting this object to 'Boost charge' will charge the battery in boost mode. If the charge method is already in the desired state nothing will happen. |
| INT upsInverterOnOff_fifth | 1.3.6.1.4.1.818.1.1.15.8.11 | INTEGER | read-write | The present state of the inverter. Setting this object to 'on' will cause the inverter to be turned on. Setting this object to 'off' will turn the inverter off. If the inverter is already in the desired state nothing will happen. |
| INT upsBypassOnOff_fifth | 1.3.6.1.4.1.818.1.1.15.8.12 | INTEGER | read-write | The present state of the bypass. Setting this object to 'on' will cause the bypass to be activated. Setting this object to 'off' will deactivate the bypass. If the UPS is already in the desired state nothing will happen. |
| INT upsLoadSource_fifth | 1.3.6.1.4.1.818.1.1.15.8.13 | INTEGER | read-write | The present source of the load. Setting this object to 'On bypass' will cause the load to be supplied by the bypass. Setting this object to 'On inverter' will cause the load to be supplied by the inverter. If the load is already supplied by the desired source nothing will happen. |
| upsConfig_fifth | 1.3.6.1.4.1.818.1.1.15.9 | |||
| NUM upsConfigInputVoltage_fifth | 1.3.6.1.4.1.818.1.1.15.9.1 | NonNegativeInteger32 | read-write | The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigInputFreq_fifth | 1.3.6.1.4.1.818.1.1.15.9.2 | NonNegativeInteger32 | read-write | The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVoltage_fifth | 1.3.6.1.4.1.818.1.1.15.9.3 | NonNegativeInteger32 | read-write | The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputFreq_fifth | 1.3.6.1.4.1.818.1.1.15.9.4 | NonNegativeInteger32 | read-write | The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVA_fifth | 1.3.6.1.4.1.818.1.1.15.9.5 | NonNegativeInteger32 | read-only | The magnitude of the nominal Volt-Amp rating.(*) |
| NUM upsConfigOutputPower_fifth | 1.3.6.1.4.1.818.1.1.15.9.6 | NonNegativeInteger32 | read-only | The magnitude of the nominal true power rating.(*) |
| NUM upsConfigLowBattTime_fifth | 1.3.6.1.4.1.818.1.1.15.9.7 | NonNegativeInteger32 | read-write | The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.(*) |
| INT upsConfigAudibleStatus_fifth | 1.3.6.1.4.1.818.1.1.15.9.8 | INTEGER | read-write | The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.(*) |
| NUM upsConfigLowVoltageTransferPoint_fifth | 1.3.6.1.4.1.818.1.1.15.9.9 | NonNegativeInteger32 | read-write | The minimum input line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigHighVoltageTransferPoint_fifth | 1.3.6.1.4.1.818.1.1.15.9.10 | NonNegativeInteger32 | read-write | The maximum line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigBatteryCapacity_fifth | 1.3.6.1.4.1.818.1.1.15.9.11 | NonNegativeInteger32 | read-write | The installed battery capacity. This value is the 'factory'-value, not the value after calibration. |
| NUM upsConfigBatteryChargeCurrent_fifth | 1.3.6.1.4.1.818.1.1.15.9.12 | NonNegativeInteger32 | read-write | The maximum battery charge current, including external chargers. |
| INT upsConfigNoLoadShutdown_fifth | 1.3.6.1.4.1.818.1.1.15.9.13 | INTEGER | read-write | Dis- or enable 'no load' shutdown from the contact interface. |
| NUM upsConfigStartDelay_fifth | 1.3.6.1.4.1.818.1.1.15.9.14 | PositiveInteger32 | read-write | Minimum required autonomy time before the UPS may perform an autorestart. |
| upsGetSet_fifth | 1.3.6.1.4.1.818.1.1.15.10 | |||
| NUM upsEventGetNext_fifth | 1.3.6.1.4.1.818.1.1.15.10.1 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventSetStartingTimeStamp will be used as the start value of the table with the lowest index number. |
| NUM upsEventGetPrevious_fifth | 1.3.6.1.4.1.818.1.1.15.10.2 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventLastTime will be used as the last value of the table with the highest index number. Returns SNMP-NOSUCHNAME for UPSs that don't support this command. |
| NUM upsEventSetStartingTimeStamp_fifth | 1.3.6.1.4.1.818.1.1.15.10.3 | NonNegativeInteger32 | read-write | The timestamp which is used as starting point for downloading events from the UPS event buffer |
| NUM upsEventRetreiveCurrentTimeStamp_fifth | 1.3.6.1.4.1.818.1.1.15.10.4 | NonNegativeInteger32 | read-only | The current timestamp is retreived from the UPS |
| NUM upsEventTableSize_fifth | 1.3.6.1.4.1.818.1.1.15.10.5 | NonNegativeInteger32 | read-only | The number of entries in the event table. This object indicates the number of rows in the event table. |
| upsEventTable_fifth | 1.3.6.1.4.1.818.1.1.15.10.6 | not-accessible | A list of event table entries. The number of entries is always 10, and the value of upsEventTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..10)): PDU-SET upsSetStartingTimeStamp PDU-SET upsEventGetNext PDU-GET upsEventTableSize PDU-GET upsEventCode,upsEventStatus,upsEventTime 1 PDU-GET upsEventCode,upsEventStatus,upsEventTime 2 .. PDU-GET upsEventCode,upsEventStatus,upsEventTime The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsEventTableSize. | |
| upsEventEntry_fifth | 1.3.6.1.4.1.818.1.1.15.10.6.1 | not-accessible | An entry containing information applicable to a particular event. | |
| NUM upsEventLineIndex_fifth | 1.3.6.1.4.1.818.1.1.15.10.6.1.1 | PositiveInteger32 | not-accessible | The event line identifier. |
| NUM upsEventCode_fifth | 1.3.6.1.4.1.818.1.1.15.10.6.1.2 | NonNegativeInteger32 | read-only | The event code in numerical format. |
| NUM upsEventStatus_fifth | 1.3.6.1.4.1.818.1.1.15.10.6.1.3 | NonNegativeInteger32 | read-only | The status of the UPS at the moment that the event was generated. The format is specified at the 'upsStatus' command. If the UPS is not able to deliver status information, then SNMP-NOSUCHNAME is returned. |
| NUM upsEventTime_fifth | 1.3.6.1.4.1.818.1.1.15.10.6.1.4 | NonNegativeInteger32 | read-only | The timestamp of the moment the event was generated. |
| NUM upsParametersRead_fifth | 1.3.6.1.4.1.818.1.1.15.10.7 | PositiveInteger32 | read-write | The number of parameters to retreive from the UPS. When this object is set the ParameterTable will be filled with the requested number of entries. The value upsParametersStartAddress will be used as the start value of the table with the lowest index number. |
| NUM upsParametersWrite_fifth | 1.3.6.1.4.1.818.1.1.15.10.8 | PositiveInteger32 | read-write | The number of parameters to write to the UPS. When this object is set the ParameterTable will be send to the ups. The value upsParametersStartAddress will be used for the first value of the table with the lowest index number. |
| NUM upsParametersStartAddress_fifth | 1.3.6.1.4.1.818.1.1.15.10.9 | NonNegativeInteger32 | read-write | The address which is used as starting point for downloading parameters from the UPS |
| NUM upsParameterTableSize_fifth | 1.3.6.1.4.1.818.1.1.15.10.10 | NonNegativeInteger32 | read-only | The number of entries in the parameter table. This object indicates the number of rows in the parameter table. |
| upsParameterTable_fifth | 1.3.6.1.4.1.818.1.1.15.10.11 | not-accessible | A list of parameter entries. The number of entries is always 16, and the value of upsParameterTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..16)): Read sequence: PDU-SET upsSetStartingAddress PDU-SET upsParametersRead PDU-GET upsParameterTableSize PDU-GET upsParameterValue 1 PDU-GET upsParameterValue 2 .. PDU-GET upsParameterValue The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsParameterTableSize. Write sequence: PDU-SET upsSetStartingAddress PDU-SET upsParameterValue 1 PDU-SET upsParameterValue 2 .. PDU-SET upsParameterValue PDU-SET upsParametersWrite | |
| upsParameterEntry_fifth | 1.3.6.1.4.1.818.1.1.15.10.11.1 | not-accessible | An entry containing information applicable to a particular parameter. | |
| NUM upsParameterLineIndex_fifth | 1.3.6.1.4.1.818.1.1.15.10.11.1.1 | PositiveInteger32 | not-accessible | The parameter line identifier. |
| I32 upsParameterValue_fifth | 1.3.6.1.4.1.818.1.1.15.10.11.1.2 | Integer32 | read-write | The parameter value in numerical format. |
| NUM upsStatus_fifth | 1.3.6.1.4.1.818.1.1.15.10.12 | NonNegativeInteger32 | read-only | The global UPS status is returned. Every bit reflects a specific status condition. Unused bits returns as 0. The status value can also be found on other commands. The value SNMP-NOSUCHNAME means 'invalid status' or 'status value non available'. Status 1 0001h upsStatusEcomodeIsOn 2 0002h upsStatusBatteryIsCharging 4 0004h upsStatusBatteryIsDischarging 8 0008h upsStatusAlarmIsActive 16 0010h upsStatusRectifierIsOn 32 0020h upsStatusLowBattery 64 0040h upsStatusOnBypass 128 0080h upsStatusMainsBypassOK 256 0100h upsStatusMainsRectifierOK 512 0200h upsStatusDetourIsOn 1024 0400h upsStatusAcousticAlarmIsOn 2048 0800h - (not used.) 4096 1000h upsStatusInverterIsOn 8192 2000h upsStatusNotInParallel (Q1 open) 16384 4000h upsStatusResetLoadOff 32768 8000h upsStatusLoadOff |
| NUM upsMainsStatisticsMBfail_fifth | 1.3.6.1.4.1.818.1.1.15.10.13 | NonNegativeInteger32 | read-only | Count of main bypass failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsMRfail_fifth | 1.3.6.1.4.1.818.1.1.15.10.14 | NonNegativeInteger32 | read-only | Count of mains rectifier failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsB2_fifth | 1.3.6.1.4.1.818.1.1.15.10.15 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (0..2 ms), during the last 7 days. |
| NUM upsMainsStatisticsB5_fifth | 1.3.6.1.4.1.818.1.1.15.10.16 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (2..5 ms), during the last 7 days. |
| NUM upsMainsStatisticsB10_fifth | 1.3.6.1.4.1.818.1.1.15.10.17 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (5..10 ms), during the last 7 days. |
| NUM upsMainsStatisticsB200_fifth | 1.3.6.1.4.1.818.1.1.15.10.18 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (10..200 ms), during the last 7 days. |
| NUM upsMainsStatisticsBypRel_fifth | 1.3.6.1.4.1.818.1.1.15.10.19 | NonNegativeInteger32 | read-only | Bypass reliability degree [0..100%;255]. The value NOSUCHNAME means 'not available'. |
| NUM upsTime_fifth | 1.3.6.1.4.1.818.1.1.15.10.20 | NonNegativeInteger32 | read-write | The current timestamp (or real-time) of the UPS. For the format, see 'Timestamp' specifications. The write-command has to comply with the correct timestamp format expected by the UPS (counter value or real-time-clock value). Missing to doing so will result in a SNMP-fifthERROR, meaning 'command not supported'. It is possible to know which is the timestamp format supported by the UPS, by issuing a read-command or by reading events, which includes timestamps. |
| STR upsRequestPermission_fifth | 1.3.6.1.4.1.818.1.1.15.10.21 | DisplayString | write-only | An encrypted code is send to enable use of restricted write objects during a limited period of time. |
| I32 upsEventGetCode_fifth | 1.3.6.1.4.1.818.1.1.15.10.22 | Integer32 | write-only | The code which is used as starting point to downloading the events from the UPS event buffer. |
| TES upsEventSpinLock_fifth | 1.3.6.1.4.1.818.1.1.15.10.23 | TestAndIncr | read-write | A spin lock on the event subsystem. |
| TES upsParameterSpinLock_fifth | 1.3.6.1.4.1.818.1.1.15.10.24 | TestAndIncr | read-write | A spin lock on the parameters subsystem. |
| geUPSTraps_fifth | 1.3.6.1.4.1.818.1.1.15.11 | |||
| NTF upsAlarmBatteryBadTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.1 | One or more batteries have been determined to require replacement. | ||
| NTF upsAlarmOnBatteryTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.2 | An On Battery condition is restored. | ||
| NTF upsAlarmLowBatteryTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime. | ||
| NTF upsAlarmDepletedBatteryTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.4 | The UPS will be unable to sustain the present load when and if the utility power is lost) | ||
| NTF upsAlarmTempBadTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.5 | A temperature is out of tolerance. | ||
| NTF upsAlarmInputBadTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.6 | An input condition is out of tolerance. | ||
| NTF upsAlarmOutputBadTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.7 | An output condition (other than OutputOverload) is out of tolerance. | ||
| NTF upsAlarmOutputOverloadTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.8 | The output load exceeds the UPS output capacity. | ||
| NTF upsAlarmOnBypassTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.9 | The Bypass is presently engaged on the UPS. | ||
| NTF upsAlarmBypassBadTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.10 | The Bypass is out of tolerance. | ||
| NTF upsAlarmOutputOffAsRequestedTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.11 | The UPS has shutdown as requested, i.e., the output is off. | ||
| NTF upsAlarmUpsOffAsRequestedTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.12 | The entire UPS has shutdown as commanded. | ||
| NTF upsAlarmChargerFailedTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.13 | An uncorrected problem has been detected within the UPS charger subsystem. | ||
| NTF upsAlarmUpsOutputOffTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.14 | The output of the UPS is in the off state. | ||
| NTF upsAlarmUpsSystemOffTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.15 | The UPS system is in the off state. | ||
| NTF upsAlarmFanFailureTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.16 | The failure of one or more fans in the UPS has been detected. | ||
| NTF upsAlarmFuseFailureTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.17 | The failure of one or more fuses has been detected. | ||
| NTF upsAlarmGeneralFaultTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.18 | A general fault in the UPS has been detected. | ||
| NTF upsAlarmDiagnosticTestFailedTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.19 | The result of the last diagnostic test indicates a failure. | ||
| NTF upsAlarmCommunicationsLostTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.20 | A problem has been encountered in the communication between the agent and the UPS. | ||
| NTF upsAlarmAwaitingPowerTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.21 | The UPS output is off and the UPS is awaiting the return of the input power (*). | ||
| NTF upsAlarmShutdownPendingTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.22 | A upsShutdownAfterDelay countdown is underway. | ||
| NTF upsAlarmShutdownImminentTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | ||
| NTF upsAlarmTestInProgressTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | ||
| NTF upsAlarmReceptacleOffTrap_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.25 | A receptacle has been switched off. | ||
| NTF upsAlarmBatteryBadRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.33 | A Battery bad condition is restored. | ||
| NTF upsAlarmOnBatteryRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.34 | The UPS is drawing power from mains again. | ||
| NTF upsAlarmLowBatteryRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.35 | A Low Battery condition is restored. | ||
| NTF upsAlarmDepletedBatteryRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.36 | A Depleted Battery condition is restored. | ||
| NTF upsAlarmTempBadRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.37 | A bad temperature condition is restored. | ||
| NTF upsAlarmInputBadRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.38 | An input bad condition is restored. | ||
| NTF upsAlarmOutputBadRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.39 | An output bad condition is restored. | ||
| NTF upsAlarmOutputOverloadRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.40 | An output overload condition is restored. | ||
| NTF upsAlarmOnBypassRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.41 | An On Bypass condition is restored. | ||
| NTF upsAlarmBypassBadRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.42 | A Bypass bad condition is restored. | ||
| NTF upsAlarmOutputOffAsRequestedRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.43 | A request shutdown has been restored. | ||
| NTF upsAlarmUpsOffAsRequestedRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.44 | A entire UPS command has been restored. | ||
| NTF upsAlarmChargerFailedRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.45 | A Charger Failer condition is restored. | ||
| NTF upsAlarmUpsOutputOn_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.46 | The output of the UPS switched in the on state. | ||
| NTF upsAlarmUpsSystemOn_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.47 | The UPS system is switched in the on state. | ||
| NTF upsAlarmFanFailureRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.48 | A Fan failure condition is restored. | ||
| NTF upsAlarmFuseFailureRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.49 | A Fuse failure condition is restored. | ||
| NTF upsAlarmGeneralFaultRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.50 | A general fault is restored. | ||
| NTF upsAlarmDiagnosticTestFailedRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.51 | A last diagnostic test indicates a failure is restored. | ||
| NTF upsAlarmCommunicationsLostRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.52 | A problem in the communication between the agent and the UPS is restored. | ||
| NTF upsAlarmAwaitingPowerRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.53 | A awaiting power condition is restored (*). | ||
| NTF upsAlarmShutdownPendingRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.54 | A upsShutdownAfterDelay countdown is restored. | ||
| NTF upsAlarmShutdownImminentRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.55 | A shutdown imminent condition is restored. | ||
| NTF upsAlarmTestInProgressRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.56 | The test is in progress is terminated. | ||
| NTF upsAlarmReceptacleOn_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.57 | A receptacle has been switched on. | ||
| NTF upsAlarmValueLow_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.129 | A measurement value reached a value below its low-level threshold. | ||
| NTF upsAlarmValueHigh_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.130 | A measurement value reached a value higher than its high-level threshold. | ||
| NTF upsAlarmValueLowRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.133 | A ValueLow alarm condition is restored. | ||
| NTF upsAlarmValueHighRestored_fifth | 1.3.6.1.4.1.818.1.1.15.11.0.134 | A ValueHigh alarm condition is restored. | ||
| geSixthUPS | 1.3.6.1.4.1.818.1.1.16 | |||
| upsIdent_sixth | 1.3.6.1.4.1.818.1.1.16.1 | |||
| STR upsIdentManufacturer_sixth | 1.3.6.1.4.1.818.1.1.16.1.1 | DisplayString | read-only | The name of the UPS manufacturer.(*) |
| STR upsIdentModel_sixth | 1.3.6.1.4.1.818.1.1.16.1.2 | DisplayString | read-only | The UPS Model designation.(*) |
| STR upsIdentUPSSoftwareVersion_sixth | 1.3.6.1.4.1.818.1.1.16.1.3 | DisplayString | read-only | The UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.(*) |
| STR upsIdentAgentSoftwareVersion_sixth | 1.3.6.1.4.1.818.1.1.16.1.4 | DisplayString | read-only | The UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.(*) |
| STR upsIdentName_sixth | 1.3.6.1.4.1.818.1.1.16.1.5 | DisplayString | read-write | A string identifying the UPS. This object should be set by the administrator.(*) |
| STR upsIdentAttachedDevices_sixth | 1.3.6.1.4.1.818.1.1.16.1.6 | DisplayString | read-write | A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.(*) |
| STR upsIdentUPSSerialNumber_sixth | 1.3.6.1.4.1.818.1.1.16.1.7 | DisplayString | read-only | The UPS serial number |
| STR upsIdentComProtVersion_sixth | 1.3.6.1.4.1.818.1.1.16.1.8 | DisplayString | read-only | The IMV communication protocol version |
| NUM upsIdentOperatingTime_sixth | 1.3.6.1.4.1.818.1.1.16.1.9 | NonNegativeInteger32 | read-only | The present value of the operating time. total 'on' time since UPS manufactured |
| upsBattery_sixth | 1.3.6.1.4.1.818.1.1.16.2 | |||
| INT upsBatteryStatus_sixth | 1.3.6.1.4.1.818.1.1.16.2.1 | INTEGER | read-only | The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).(*) |
| NUM upsSecondsOnBattery_sixth | 1.3.6.1.4.1.818.1.1.16.2.2 | NonNegativeInteger32 | read-only | If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.(*) |
| NUM upsEstimatedMinutesRemaining_sixth | 1.3.6.1.4.1.818.1.1.16.2.3 | PositiveInteger32 | read-only | An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.(*) |
| I32 upsEstimatedChargeRemaining_sixth | 1.3.6.1.4.1.818.1.1.16.2.4 | Integer32 | read-only | An estimate of the battery charge remaining expressed as a percent of full charge.(*) |
| NUM upsBatteryVoltage_sixth | 1.3.6.1.4.1.818.1.1.16.2.5 | NonNegativeInteger32 | read-only | The magnitude of the present battery voltage.(*) |
| I32 upsBatteryCurrent_sixth | 1.3.6.1.4.1.818.1.1.16.2.6 | Integer32 | read-only | The present battery current.(*) |
| I32 upsBatteryTemperature_sixth | 1.3.6.1.4.1.818.1.1.16.2.7 | Integer32 | read-only | The ambient temperature at or near the UPS Battery casing.(*) |
| upsInput_sixth | 1.3.6.1.4.1.818.1.1.16.3 | |||
| C32 upsInputLineBads_sixth | 1.3.6.1.4.1.818.1.1.16.3.1 | Counter32 | read-only | A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.(*) |
| NUM upsInputNumLines_sixth | 1.3.6.1.4.1.818.1.1.16.3.2 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This variable indicates the number of rows in the input table.(*) |
| upsInputTable_sixth | 1.3.6.1.4.1.818.1.1.16.3.3 | not-accessible | A list of input table entries. The number of entries is given by the value of upsInputNumLines.(*) | |
| upsInputEntry_sixth | 1.3.6.1.4.1.818.1.1.16.3.3.1 | not-accessible | An entry containing information applicable to a particular input line.(*) | |
| NUM upsInputLineIndex_sixth | 1.3.6.1.4.1.818.1.1.16.3.3.1.1 | PositiveInteger32 | not-accessible | The input line identifier.(*) |
| NUM upsInputFrequency_sixth | 1.3.6.1.4.1.818.1.1.16.3.3.1.2 | NonNegativeInteger32 | read-only | The present input frequency.(*) |
| NUM upsInputVoltage_sixth | 1.3.6.1.4.1.818.1.1.16.3.3.1.3 | NonNegativeInteger32 | read-only | The magnitude of the present input voltage.(*) |
| NUM upsInputCurrent_sixth | 1.3.6.1.4.1.818.1.1.16.3.3.1.4 | NonNegativeInteger32 | read-only | The magnitude of the present input current.(*) |
| NUM upsInputTruePower_sixth | 1.3.6.1.4.1.818.1.1.16.3.3.1.5 | NonNegativeInteger32 | read-only | The magnitude of the present input true power.(*) |
| NUM upsInputVoltageMin_sixth | 1.3.6.1.4.1.818.1.1.16.3.3.1.6 | NonNegativeInteger32 | read-only | The lowest magnitude of the input voltage since last read out. |
| NUM upsInputVoltageMax_sixth | 1.3.6.1.4.1.818.1.1.16.3.3.1.7 | NonNegativeInteger32 | read-only | The highest magnitude of the input voltage since last read out. |
| upsOutput_sixth | 1.3.6.1.4.1.818.1.1.16.4 | |||
| INT upsOutputSource_sixth | 1.3.6.1.4.1.818.1.1.16.4.1 | INTEGER | read-only | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.(*) |
| NUM upsOutputFrequency_sixth | 1.3.6.1.4.1.818.1.1.16.4.2 | NonNegativeInteger32 | read-only | The present output frequency.(*) |
| NUM upsOutputNumLines_sixth | 1.3.6.1.4.1.818.1.1.16.4.3 | NonNegativeInteger32 | read-only | The number of output lines utilized in this device. This variable indicates the number of rows in the output table.(*) |
| upsOutputTable_sixth | 1.3.6.1.4.1.818.1.1.16.4.4 | not-accessible | A list of output table entries. The number of entries is given by the value of upsOutputNumLines.(*) | |
| upsOutputEntry_sixth | 1.3.6.1.4.1.818.1.1.16.4.4.1 | not-accessible | An entry containing information applicable to a particular output line.(*) | |
| NUM upsOutputLineIndex_sixth | 1.3.6.1.4.1.818.1.1.16.4.4.1.1 | PositiveInteger32 | not-accessible | The output line identifier.(*) |
| NUM upsOutputVoltage_sixth | 1.3.6.1.4.1.818.1.1.16.4.4.1.2 | NonNegativeInteger32 | read-only | The present output voltage.(*) |
| NUM upsOutputCurrent_sixth | 1.3.6.1.4.1.818.1.1.16.4.4.1.3 | NonNegativeInteger32 | read-only | The present output current.(*) |
| NUM upsOutputPower_sixth | 1.3.6.1.4.1.818.1.1.16.4.4.1.4 | NonNegativeInteger32 | read-only | The present output true power.(*) |
| I32 upsOutputPercentLoad_sixth | 1.3.6.1.4.1.818.1.1.16.4.4.1.5 | Integer32 | read-only | The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.(*) |
| upsBypass_sixth | 1.3.6.1.4.1.818.1.1.16.5 | |||
| NUM upsBypassFrequency_sixth | 1.3.6.1.4.1.818.1.1.16.5.1 | NonNegativeInteger32 | read-only | The present bypass frequency.(*) |
| NUM upsBypassNumLines_sixth | 1.3.6.1.4.1.818.1.1.16.5.2 | NonNegativeInteger32 | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.(*) |
| upsBypassTable_sixth | 1.3.6.1.4.1.818.1.1.16.5.3 | not-accessible | A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.(*) | |
| upsBypassEntry_sixth | 1.3.6.1.4.1.818.1.1.16.5.3.1 | not-accessible | An entry containing information applicable to a particular bypass input.(*) | |
| NUM upsBypassLineIndex_sixth | 1.3.6.1.4.1.818.1.1.16.5.3.1.1 | PositiveInteger32 | not-accessible | The bypass line identifier.(*) |
| NUM upsBypassVoltage_sixth | 1.3.6.1.4.1.818.1.1.16.5.3.1.2 | NonNegativeInteger32 | read-only | The present bypass voltage.(*) |
| NUM upsBypassCurrent_sixth | 1.3.6.1.4.1.818.1.1.16.5.3.1.3 | NonNegativeInteger32 | read-only | The present bypass current.(*) |
| NUM upsBypassPower_sixth | 1.3.6.1.4.1.818.1.1.16.5.3.1.4 | NonNegativeInteger32 | read-only | The present true power conveyed by the bypass.(*) |
| upsAlarm_sixth | 1.3.6.1.4.1.818.1.1.16.6 | |||
| G32 upsAlarmsPresent_sixth | 1.3.6.1.4.1.818.1.1.16.6.1 | Gauge32 | read-only | The present number of active alarm conditions.(*) |
| upsAlarmTable_sixth | 1.3.6.1.4.1.818.1.1.16.6.2 | not-accessible | A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent.(*) | |
| upsAlarmEntry_sixth | 1.3.6.1.4.1.818.1.1.16.6.2.1 | not-accessible | An entry containing information applicable to a particular alarm.(*) | |
| NUM upsAlarmId_sixth | 1.3.6.1.4.1.818.1.1.16.6.2.1.1 | PositiveInteger32 | not-accessible | A unique identifier for an alarm condition. This value must remain constant.(*) |
| OID upsAlarmDescr_sixth | 1.3.6.1.4.1.818.1.1.16.6.2.1.2 | AutonomousType | read-only | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.(*) |
| TIM upsAlarmTime_sixth | 1.3.6.1.4.1.818.1.1.16.6.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.(*) |
| upsWellKnownAlarms_sixth | 1.3.6.1.4.1.818.1.1.16.6.3 | |||
| upsAlarmBatteryBad_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.1 | One or more batteries have been determined to require replacement.(*) | ||
| upsAlarmOnBattery_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.2 | The UPS is drawing power from the batteries.(*) | ||
| upsAlarmLowBattery_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime.(*) | ||
| upsAlarmDepletedBattery_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.4 | The UPS will be unable to sustain the present load when and if the utility power is lost.(*) | ||
| upsAlarmTempBad_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.5 | A temperature is out of tolerance.(*) | ||
| upsAlarmInputBad_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.6 | An input condition is out of tolerance.(*) | ||
| upsAlarmOutputBad_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.7 | An output condition (other than OutputOverload) is out of tolerance.(*) | ||
| upsAlarmOutputOverload_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.8 | The output load exceeds the UPS output capacity.(*) | ||
| upsAlarmOnBypass_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.9 | The Bypass is presently engaged on the UPS.(*) | ||
| upsAlarmBypassBad_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.10 | The Bypass is out of tolerance.(*) | ||
| upsAlarmOutputOffAsRequested_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.11 | The UPS has shutdown as requested, i.e., the output is off.(*) | ||
| upsAlarmUpsOffAsRequested_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.12 | The entire UPS has shutdown as commanded.(*) | ||
| upsAlarmChargerFailed_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.13 | An uncorrected problem has been detected within the UPS charger subsystem.(*) | ||
| upsAlarmUpsOutputOff_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.14 | The output of the UPS is in the off state.(*) | ||
| upsAlarmUpsSystemOff_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.15 | The UPS system is in the off state.(*) | ||
| upsAlarmFanFailure_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.16 | The failure of one or more fans in the UPS has been detected.(*) | ||
| upsAlarmFuseFailure_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.17 | The failure of one or more fuses has been detected.(*) | ||
| upsAlarmGeneralFault_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.18 | A general fault in the UPS has been detected.(*) | ||
| upsAlarmDiagnosticTestFailed_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.19 | The result of the last diagnostic test indicates a failure.(*) | ||
| upsAlarmCommunicationsLost_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.20 | A problem has been encountered in the communications between the agent and the UPS.(*) | ||
| upsAlarmAwaitingPower_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.21 | The UPS output is off and the UPS is awaiting the return of input power.(*) | ||
| upsAlarmShutdownPending_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.22 | A upsShutdownAfterDelay countdown is underway.(*) | ||
| upsAlarmShutdownImminent_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.(*) | ||
| upsAlarmTestInProgress_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY.(*) | ||
| upsAlarmReceptacleOff_sixth | 1.3.6.1.4.1.818.1.1.16.6.3.25 | The receptacle are switch off | ||
| NUM upsAlarmMaskA_sixth | 1.3.6.1.4.1.818.1.1.16.6.4 | NonNegativeInteger32 | read-only | Specifies which alarm can be handled by the UPS. The 'Mask' parameter is a Long Integer32. The meaning of every bit is the same as for the 'upsAlarmGroupA' command. A bit having value=1 indicates that the corresponding alarm is handled by the UPS. |
| upsTest_sixth | 1.3.6.1.4.1.818.1.1.16.7 | |||
| OID upsTestId_sixth | 1.3.6.1.4.1.818.1.1.16.7.1 | OBJECT IDENTIFIER | read-write | The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned.(*) |
| TES upsTestSpinLock_sixth | 1.3.6.1.4.1.818.1.1.16.7.2 | TestAndIncr | read-write | A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try-again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock-value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock-value, upsTestId = requested-test) if (error-index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try-again } if (error-index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by polling upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock-value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1.(*) |
| INT upsTestResultsSummary_sixth | 1.3.6.1.4.1.818.1.1.16.7.3 | INTEGER | read-only | The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.(*) |
| STR upsTestResultsDetail_sixth | 1.3.6.1.4.1.818.1.1.16.7.4 | DisplayString | read-only | Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned.(*) |
| TIM upsTestStartTime_sixth | 1.3.6.1.4.1.818.1.1.16.7.5 | TimeStamp | read-only | The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0.(*) |
| NUM upsTestElapsedTime_sixth | 1.3.6.1.4.1.818.1.1.16.7.6 | TimeInterval | read-only | The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0.(*) |
| upsWellKnownTests_sixth | 1.3.6.1.4.1.818.1.1.16.7.7 | |||
| upsTestNoTestsInitiated_sixth | 1.3.6.1.4.1.818.1.1.16.7.7.1 | No tests have been initiated and no test is in progress.(*) | ||
| upsTestAbortTestInProgress_sixth | 1.3.6.1.4.1.818.1.1.16.7.7.2 | The test in progress is to be aborted / the test in progress was aborted.(*) | ||
| upsTestGeneralSystemsTest_sixth | 1.3.6.1.4.1.818.1.1.16.7.7.3 | The manufacturer's standard test of UPS device systems.(*) | ||
| upsTestQuickBatteryTest_sixth | 1.3.6.1.4.1.818.1.1.16.7.7.4 | A test that is sufficient to determine if the battery needs replacement.(*) | ||
| upsTestDeepBatteryCalibration_sixth | 1.3.6.1.4.1.818.1.1.16.7.7.5 | The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load.(*) | ||
| upsControl_sixth | 1.3.6.1.4.1.818.1.1.16.8 | |||
| INT upsShutdownType_sixth | 1.3.6.1.4.1.818.1.1.16.8.1 | INTEGER | read-write | This object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.(*) |
| I32 upsShutdownAfterDelay_sixth | 1.3.6.1.4.1.818.1.1.16.8.2 | Integer32 | read-write | Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.(*) |
| I32 upsStartupAfterDelay_sixth | 1.3.6.1.4.1.818.1.1.16.8.3 | Integer32 | read-write | Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.(*) |
| I32 upsRebootWithDuration_sixth | 1.3.6.1.4.1.818.1.1.16.8.4 | Integer32 | read-write | Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.(*) |
| INT upsAutoRestart_sixth | 1.3.6.1.4.1.818.1.1.16.8.5 | INTEGER | read-write | Setting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutdownAfterDelay or an internal battery depleted condition. Setting this object to 'off' will prevent the UPS system from restarting after a shutdown until an operator manually or remotely explicitly restarts it. If the UPS is in a startup or reboot countdown, then the UPS will not restart until that delay has been satisfied.(*) |
| NUM upsReceptaclesNum_sixth | 1.3.6.1.4.1.818.1.1.16.8.6 | NonNegativeInteger32 | read-only | The number of receptacles utilized in this device. This entry indicates the number of rows in the receptacle table. |
| upsReceptacleTable_sixth | 1.3.6.1.4.1.818.1.1.16.8.7 | not-accessible | A list of receptacle table entries. The number of entries is given by the value of upsReceptacleNum. | |
| upsReceptacleEntry_sixth | 1.3.6.1.4.1.818.1.1.16.8.7.1 | not-accessible | An entry containing information applicable to a particular receptacle. | |
| NUM upsReceptacleLineIndex_sixth | 1.3.6.1.4.1.818.1.1.16.8.7.1.1 | PositiveInteger32 | not-accessible | The receptacle line identifier. |
| INT upsReceptacleOnOff_sixth | 1.3.6.1.4.1.818.1.1.16.8.7.1.2 | INTEGER | read-write | The present state of the receptacle. Setting this object to 'on' will cause the receptacle to be turned on. Setting this object to 'off' will turn the receptacle off. If the receptacle is already in the desired state nothing will happen. After an autorestart (see upsAutoRestart) the receptacle will be on. |
| INT upsUPSMode_sixth | 1.3.6.1.4.1.818.1.1.16.8.8 | INTEGER | read-write | The operation mode off the UPS. Off-line indicates a mode in which the input power is transferred to the output directly or via a step-up or step-down transformer. On-line mode indicates a mode in which the output power is regenerated through some convertor. the operating mode of the UPS may be fixed, or may be selectable (e.g. an on-line UPS with ecomode) |
| INT upsRectifierOnOff_sixth | 1.3.6.1.4.1.818.1.1.16.8.9 | INTEGER | read-write | The present state of the rectifier. Setting this object to 'on' will cause the rectifier to be turned on. Setting this object to 'off' will turn the rectifier off. If the rectifier is already in the desired state nothing will happen. |
| INT upsBatteryChargeMethod_sixth | 1.3.6.1.4.1.818.1.1.16.8.10 | INTEGER | read-write | The present state of the charge method. Setting this object to 'Normal charge' will cause the battery to be charged using the normal method. Setting this object to 'Boost charge' will charge the battery in boost mode. If the charge method is already in the desired state nothing will happen. |
| INT upsInverterOnOff_sixth | 1.3.6.1.4.1.818.1.1.16.8.11 | INTEGER | read-write | The present state of the inverter. Setting this object to 'on' will cause the inverter to be turned on. Setting this object to 'off' will turn the inverter off. If the inverter is already in the desired state nothing will happen. |
| INT upsBypassOnOff_sixth | 1.3.6.1.4.1.818.1.1.16.8.12 | INTEGER | read-write | The present state of the bypass. Setting this object to 'on' will cause the bypass to be activated. Setting this object to 'off' will deactivate the bypass. If the UPS is already in the desired state nothing will happen. |
| INT upsLoadSource_sixth | 1.3.6.1.4.1.818.1.1.16.8.13 | INTEGER | read-write | The present source of the load. Setting this object to 'On bypass' will cause the load to be supplied by the bypass. Setting this object to 'On inverter' will cause the load to be supplied by the inverter. If the load is already supplied by the desired source nothing will happen. |
| upsConfig_sixth | 1.3.6.1.4.1.818.1.1.16.9 | |||
| NUM upsConfigInputVoltage_sixth | 1.3.6.1.4.1.818.1.1.16.9.1 | NonNegativeInteger32 | read-write | The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigInputFreq_sixth | 1.3.6.1.4.1.818.1.1.16.9.2 | NonNegativeInteger32 | read-write | The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVoltage_sixth | 1.3.6.1.4.1.818.1.1.16.9.3 | NonNegativeInteger32 | read-write | The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputFreq_sixth | 1.3.6.1.4.1.818.1.1.16.9.4 | NonNegativeInteger32 | read-write | The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVA_sixth | 1.3.6.1.4.1.818.1.1.16.9.5 | NonNegativeInteger32 | read-only | The magnitude of the nominal Volt-Amp rating.(*) |
| NUM upsConfigOutputPower_sixth | 1.3.6.1.4.1.818.1.1.16.9.6 | NonNegativeInteger32 | read-only | The magnitude of the nominal true power rating.(*) |
| NUM upsConfigLowBattTime_sixth | 1.3.6.1.4.1.818.1.1.16.9.7 | NonNegativeInteger32 | read-write | The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.(*) |
| INT upsConfigAudibleStatus_sixth | 1.3.6.1.4.1.818.1.1.16.9.8 | INTEGER | read-write | The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.(*) |
| NUM upsConfigLowVoltageTransferPoint_sixth | 1.3.6.1.4.1.818.1.1.16.9.9 | NonNegativeInteger32 | read-write | The minimum input line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigHighVoltageTransferPoint_sixth | 1.3.6.1.4.1.818.1.1.16.9.10 | NonNegativeInteger32 | read-write | The maximum line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigBatteryCapacity_sixth | 1.3.6.1.4.1.818.1.1.16.9.11 | NonNegativeInteger32 | read-write | The installed battery capacity. This value is the 'factory'-value, not the value after calibration. |
| NUM upsConfigBatteryChargeCurrent_sixth | 1.3.6.1.4.1.818.1.1.16.9.12 | NonNegativeInteger32 | read-write | The maximum battery charge current, including external chargers. |
| INT upsConfigNoLoadShutdown_sixth | 1.3.6.1.4.1.818.1.1.16.9.13 | INTEGER | read-write | Dis- or enable 'no load' shutdown from the contact interface. |
| NUM upsConfigStartDelay_sixth | 1.3.6.1.4.1.818.1.1.16.9.14 | PositiveInteger32 | read-write | Minimum required autonomy time before the UPS may perform an autorestart. |
| upsGetSet_sixth | 1.3.6.1.4.1.818.1.1.16.10 | |||
| NUM upsEventGetNext_sixth | 1.3.6.1.4.1.818.1.1.16.10.1 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventSetStartingTimeStamp will be used as the start value of the table with the lowest index number. |
| NUM upsEventGetPrevious_sixth | 1.3.6.1.4.1.818.1.1.16.10.2 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventLastTime will be used as the last value of the table with the highest index number. Returns SNMP-NOSUCHNAME for UPSs that don't support this command. |
| NUM upsEventSetStartingTimeStamp_sixth | 1.3.6.1.4.1.818.1.1.16.10.3 | NonNegativeInteger32 | read-write | The timestamp which is used as starting point for downloading events from the UPS event buffer |
| NUM upsEventRetreiveCurrentTimeStamp_sixth | 1.3.6.1.4.1.818.1.1.16.10.4 | NonNegativeInteger32 | read-only | The current timestamp is retreived from the UPS |
| NUM upsEventTableSize_sixth | 1.3.6.1.4.1.818.1.1.16.10.5 | NonNegativeInteger32 | read-only | The number of entries in the event table. This object indicates the number of rows in the event table. |
| upsEventTable_sixth | 1.3.6.1.4.1.818.1.1.16.10.6 | not-accessible | A list of event table entries. The number of entries is always 10, and the value of upsEventTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..10)): PDU-SET upsSetStartingTimeStamp PDU-SET upsEventGetNext PDU-GET upsEventTableSize PDU-GET upsEventCode,upsEventStatus,upsEventTime 1 PDU-GET upsEventCode,upsEventStatus,upsEventTime 2 .. PDU-GET upsEventCode,upsEventStatus,upsEventTime The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsEventTableSize. | |
| upsEventEntry_sixth | 1.3.6.1.4.1.818.1.1.16.10.6.1 | not-accessible | An entry containing information applicable to a particular event. | |
| NUM upsEventLineIndex_sixth | 1.3.6.1.4.1.818.1.1.16.10.6.1.1 | PositiveInteger32 | not-accessible | The event line identifier. |
| NUM upsEventCode_sixth | 1.3.6.1.4.1.818.1.1.16.10.6.1.2 | NonNegativeInteger32 | read-only | The event code in numerical format. |
| NUM upsEventStatus_sixth | 1.3.6.1.4.1.818.1.1.16.10.6.1.3 | NonNegativeInteger32 | read-only | The status of the UPS at the moment that the event was generated. The format is specified at the 'upsStatus' command. If the UPS is not able to deliver status information, then SNMP-NOSUCHNAME is returned. |
| NUM upsEventTime_sixth | 1.3.6.1.4.1.818.1.1.16.10.6.1.4 | NonNegativeInteger32 | read-only | The timestamp of the moment the event was generated. |
| NUM upsParametersRead_sixth | 1.3.6.1.4.1.818.1.1.16.10.7 | PositiveInteger32 | read-write | The number of parameters to retreive from the UPS. When this object is set the ParameterTable will be filled with the requested number of entries. The value upsParametersStartAddress will be used as the start value of the table with the lowest index number. |
| NUM upsParametersWrite_sixth | 1.3.6.1.4.1.818.1.1.16.10.8 | PositiveInteger32 | read-write | The number of parameters to write to the UPS. When this object is set the ParameterTable will be send to the ups. The value upsParametersStartAddress will be used for the first value of the table with the lowest index number. |
| NUM upsParametersStartAddress_sixth | 1.3.6.1.4.1.818.1.1.16.10.9 | NonNegativeInteger32 | read-write | The address which is used as starting point for downloading parameters from the UPS |
| NUM upsParameterTableSize_sixth | 1.3.6.1.4.1.818.1.1.16.10.10 | NonNegativeInteger32 | read-only | The number of entries in the parameter table. This object indicates the number of rows in the parameter table. |
| upsParameterTable_sixth | 1.3.6.1.4.1.818.1.1.16.10.11 | not-accessible | A list of parameter entries. The number of entries is always 16, and the value of upsParameterTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..16)): Read sequence: PDU-SET upsSetStartingAddress PDU-SET upsParametersRead PDU-GET upsParameterTableSize PDU-GET upsParameterValue 1 PDU-GET upsParameterValue 2 .. PDU-GET upsParameterValue The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsParameterTableSize. Write sequence: PDU-SET upsSetStartingAddress PDU-SET upsParameterValue 1 PDU-SET upsParameterValue 2 .. PDU-SET upsParameterValue PDU-SET upsParametersWrite | |
| upsParameterEntry_sixth | 1.3.6.1.4.1.818.1.1.16.10.11.1 | not-accessible | An entry containing information applicable to a particular parameter. | |
| NUM upsParameterLineIndex_sixth | 1.3.6.1.4.1.818.1.1.16.10.11.1.1 | PositiveInteger32 | not-accessible | The parameter line identifier. |
| I32 upsParameterValue_sixth | 1.3.6.1.4.1.818.1.1.16.10.11.1.2 | Integer32 | read-write | The parameter value in numerical format. |
| NUM upsStatus_sixth | 1.3.6.1.4.1.818.1.1.16.10.12 | NonNegativeInteger32 | read-only | The global UPS status is returned. Every bit reflects a specific status condition. Unused bits returns as 0. The status value can also be found on other commands. The value SNMP-NOSUCHNAME means 'invalid status' or 'status value non available'. Status 1 0001h upsStatusEcomodeIsOn 2 0002h upsStatusBatteryIsCharging 4 0004h upsStatusBatteryIsDischarging 8 0008h upsStatusAlarmIsActive 16 0010h upsStatusRectifierIsOn 32 0020h upsStatusLowBattery 64 0040h upsStatusOnBypass 128 0080h upsStatusMainsBypassOK 256 0100h upsStatusMainsRectifierOK 512 0200h upsStatusDetourIsOn 1024 0400h upsStatusAcousticAlarmIsOn 2048 0800h - (not used.) 4096 1000h upsStatusInverterIsOn 8192 2000h upsStatusNotInParallel (Q1 open) 16384 4000h upsStatusResetLoadOff 32768 8000h upsStatusLoadOff |
| NUM upsMainsStatisticsMBfail_sixth | 1.3.6.1.4.1.818.1.1.16.10.13 | NonNegativeInteger32 | read-only | Count of main bypass failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsMRfail_sixth | 1.3.6.1.4.1.818.1.1.16.10.14 | NonNegativeInteger32 | read-only | Count of mains rectifier failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsB2_sixth | 1.3.6.1.4.1.818.1.1.16.10.15 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (0..2 ms), during the last 7 days. |
| NUM upsMainsStatisticsB5_sixth | 1.3.6.1.4.1.818.1.1.16.10.16 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (2..5 ms), during the last 7 days. |
| NUM upsMainsStatisticsB10_sixth | 1.3.6.1.4.1.818.1.1.16.10.17 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (5..10 ms), during the last 7 days. |
| NUM upsMainsStatisticsB200_sixth | 1.3.6.1.4.1.818.1.1.16.10.18 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (10..200 ms), during the last 7 days. |
| NUM upsMainsStatisticsBypRel_sixth | 1.3.6.1.4.1.818.1.1.16.10.19 | NonNegativeInteger32 | read-only | Bypass reliability degree [0..100%;255]. The value NOSUCHNAME means 'not available'. |
| NUM upsTime_sixth | 1.3.6.1.4.1.818.1.1.16.10.20 | NonNegativeInteger32 | read-write | The current timestamp (or real-time) of the UPS. For the format, see 'Timestamp' specifications. The write-command has to comply with the correct timestamp format expected by the UPS (counter value or real-time-clock value). Missing to doing so will result in a SNMP-sixthERROR, meaning 'command not supported'. It is possible to know which is the timestamp format supported by the UPS, by issuing a read-command or by reading events, which includes timestamps. |
| STR upsRequestPermission_sixth | 1.3.6.1.4.1.818.1.1.16.10.21 | DisplayString | write-only | An encrypted code is send to enable use of restricted write objects during a limited period of time. |
| I32 upsEventGetCode_sixth | 1.3.6.1.4.1.818.1.1.16.10.22 | Integer32 | write-only | The code which is used as starting point to downloading the events from the UPS event buffer. |
| TES upsEventSpinLock_sixth | 1.3.6.1.4.1.818.1.1.16.10.23 | TestAndIncr | read-write | A spin lock on the event subsystem. |
| TES upsParameterSpinLock_sixth | 1.3.6.1.4.1.818.1.1.16.10.24 | TestAndIncr | read-write | A spin lock on the parameters subsystem. |
| geUPSTraps_sixth | 1.3.6.1.4.1.818.1.1.16.11 | |||
| NTF upsAlarmBatteryBadTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.1 | One or more batteries have been determined to require replacement. | ||
| NTF upsAlarmOnBatteryTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.2 | An On Battery condition is restored. | ||
| NTF upsAlarmLowBatteryTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime. | ||
| NTF upsAlarmDepletedBatteryTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.4 | The UPS will be unable to sustain the present load when and if the utility power is lost) | ||
| NTF upsAlarmTempBadTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.5 | A temperature is out of tolerance. | ||
| NTF upsAlarmInputBadTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.6 | An input condition is out of tolerance. | ||
| NTF upsAlarmOutputBadTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.7 | An output condition (other than OutputOverload) is out of tolerance. | ||
| NTF upsAlarmOutputOverloadTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.8 | The output load exceeds the UPS output capacity. | ||
| NTF upsAlarmOnBypassTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.9 | The Bypass is presently engaged on the UPS. | ||
| NTF upsAlarmBypassBadTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.10 | The Bypass is out of tolerance. | ||
| NTF upsAlarmOutputOffAsRequestedTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.11 | The UPS has shutdown as requested, i.e., the output is off. | ||
| NTF upsAlarmUpsOffAsRequestedTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.12 | The entire UPS has shutdown as commanded. | ||
| NTF upsAlarmChargerFailedTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.13 | An uncorrected problem has been detected within the UPS charger subsystem. | ||
| NTF upsAlarmUpsOutputOffTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.14 | The output of the UPS is in the off state. | ||
| NTF upsAlarmUpsSystemOffTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.15 | The UPS system is in the off state. | ||
| NTF upsAlarmFanFailureTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.16 | The failure of one or more fans in the UPS has been detected. | ||
| NTF upsAlarmFuseFailureTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.17 | The failure of one or more fuses has been detected. | ||
| NTF upsAlarmGeneralFaultTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.18 | A general fault in the UPS has been detected. | ||
| NTF upsAlarmDiagnosticTestFailedTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.19 | The result of the last diagnostic test indicates a failure. | ||
| NTF upsAlarmCommunicationsLostTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.20 | A problem has been encountered in the communication between the agent and the UPS. | ||
| NTF upsAlarmAwaitingPowerTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.21 | The UPS output is off and the UPS is awaiting the return of the input power (*). | ||
| NTF upsAlarmShutdownPendingTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.22 | A upsShutdownAfterDelay countdown is underway. | ||
| NTF upsAlarmShutdownImminentTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | ||
| NTF upsAlarmTestInProgressTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | ||
| NTF upsAlarmReceptacleOffTrap_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.25 | A receptacle has been switched off. | ||
| NTF upsAlarmBatteryBadRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.33 | A Battery bad condition is restored. | ||
| NTF upsAlarmOnBatteryRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.34 | The UPS is drawing power from mains again. | ||
| NTF upsAlarmLowBatteryRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.35 | A Low Battery condition is restored. | ||
| NTF upsAlarmDepletedBatteryRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.36 | A Depleted Battery condition is restored. | ||
| NTF upsAlarmTempBadRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.37 | A bad temperature condition is restored. | ||
| NTF upsAlarmInputBadRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.38 | An input bad condition is restored. | ||
| NTF upsAlarmOutputBadRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.39 | An output bad condition is restored. | ||
| NTF upsAlarmOutputOverloadRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.40 | An output overload condition is restored. | ||
| NTF upsAlarmOnBypassRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.41 | An On Bypass condition is restored. | ||
| NTF upsAlarmBypassBadRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.42 | A Bypass bad condition is restored. | ||
| NTF upsAlarmOutputOffAsRequestedRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.43 | A request shutdown has been restored. | ||
| NTF upsAlarmUpsOffAsRequestedRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.44 | A entire UPS command has been restored. | ||
| NTF upsAlarmChargerFailedRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.45 | A Charger Failer condition is restored. | ||
| NTF upsAlarmUpsOutputOn_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.46 | The output of the UPS switched in the on state. | ||
| NTF upsAlarmUpsSystemOn_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.47 | The UPS system is switched in the on state. | ||
| NTF upsAlarmFanFailureRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.48 | A Fan failure condition is restored. | ||
| NTF upsAlarmFuseFailureRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.49 | A Fuse failure condition is restored. | ||
| NTF upsAlarmGeneralFaultRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.50 | A general fault is restored. | ||
| NTF upsAlarmDiagnosticTestFailedRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.51 | A last diagnostic test indicates a failure is restored. | ||
| NTF upsAlarmCommunicationsLostRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.52 | A problem in the communication between the agent and the UPS is restored. | ||
| NTF upsAlarmAwaitingPowerRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.53 | A awaiting power condition is restored (*). | ||
| NTF upsAlarmShutdownPendingRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.54 | A upsShutdownAfterDelay countdown is restored. | ||
| NTF upsAlarmShutdownImminentRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.55 | A shutdown imminent condition is restored. | ||
| NTF upsAlarmTestInProgressRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.56 | The test is in progress is terminated. | ||
| NTF upsAlarmReceptacleOn_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.57 | A receptacle has been switched on. | ||
| NTF upsAlarmValueLow_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.129 | A measurement value reached a value below its low-level threshold. | ||
| NTF upsAlarmValueHigh_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.130 | A measurement value reached a value higher than its high-level threshold. | ||
| NTF upsAlarmValueLowRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.133 | A ValueLow alarm condition is restored. | ||
| NTF upsAlarmValueHighRestored_sixth | 1.3.6.1.4.1.818.1.1.16.11.0.134 | A ValueHigh alarm condition is restored. | ||
| geSeventhUPS | 1.3.6.1.4.1.818.1.1.17 | |||
| upsIdent_seventh | 1.3.6.1.4.1.818.1.1.17.1 | |||
| STR upsIdentManufacturer_seventh | 1.3.6.1.4.1.818.1.1.17.1.1 | DisplayString | read-only | The name of the UPS manufacturer.(*) |
| STR upsIdentModel_seventh | 1.3.6.1.4.1.818.1.1.17.1.2 | DisplayString | read-only | The UPS Model designation.(*) |
| STR upsIdentUPSSoftwareVersion_seventh | 1.3.6.1.4.1.818.1.1.17.1.3 | DisplayString | read-only | The UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.(*) |
| STR upsIdentAgentSoftwareVersion_seventh | 1.3.6.1.4.1.818.1.1.17.1.4 | DisplayString | read-only | The UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.(*) |
| STR upsIdentName_seventh | 1.3.6.1.4.1.818.1.1.17.1.5 | DisplayString | read-write | A string identifying the UPS. This object should be set by the administrator.(*) |
| STR upsIdentAttachedDevices_seventh | 1.3.6.1.4.1.818.1.1.17.1.6 | DisplayString | read-write | A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.(*) |
| STR upsIdentUPSSerialNumber_seventh | 1.3.6.1.4.1.818.1.1.17.1.7 | DisplayString | read-only | The UPS serial number |
| STR upsIdentComProtVersion_seventh | 1.3.6.1.4.1.818.1.1.17.1.8 | DisplayString | read-only | The IMV communication protocol version |
| NUM upsIdentOperatingTime_seventh | 1.3.6.1.4.1.818.1.1.17.1.9 | NonNegativeInteger32 | read-only | The present value of the operating time. total 'on' time since UPS manufactured |
| upsBattery_seventh | 1.3.6.1.4.1.818.1.1.17.2 | |||
| INT upsBatteryStatus_seventh | 1.3.6.1.4.1.818.1.1.17.2.1 | INTEGER | read-only | The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).(*) |
| NUM upsSecondsOnBattery_seventh | 1.3.6.1.4.1.818.1.1.17.2.2 | NonNegativeInteger32 | read-only | If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.(*) |
| NUM upsEstimatedMinutesRemaining_seventh | 1.3.6.1.4.1.818.1.1.17.2.3 | PositiveInteger32 | read-only | An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.(*) |
| I32 upsEstimatedChargeRemaining_seventh | 1.3.6.1.4.1.818.1.1.17.2.4 | Integer32 | read-only | An estimate of the battery charge remaining expressed as a percent of full charge.(*) |
| NUM upsBatteryVoltage_seventh | 1.3.6.1.4.1.818.1.1.17.2.5 | NonNegativeInteger32 | read-only | The magnitude of the present battery voltage.(*) |
| I32 upsBatteryCurrent_seventh | 1.3.6.1.4.1.818.1.1.17.2.6 | Integer32 | read-only | The present battery current.(*) |
| I32 upsBatteryTemperature_seventh | 1.3.6.1.4.1.818.1.1.17.2.7 | Integer32 | read-only | The ambient temperature at or near the UPS Battery casing.(*) |
| upsInput_seventh | 1.3.6.1.4.1.818.1.1.17.3 | |||
| C32 upsInputLineBads_seventh | 1.3.6.1.4.1.818.1.1.17.3.1 | Counter32 | read-only | A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.(*) |
| NUM upsInputNumLines_seventh | 1.3.6.1.4.1.818.1.1.17.3.2 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This variable indicates the number of rows in the input table.(*) |
| upsInputTable_seventh | 1.3.6.1.4.1.818.1.1.17.3.3 | not-accessible | A list of input table entries. The number of entries is given by the value of upsInputNumLines.(*) | |
| upsInputEntry_seventh | 1.3.6.1.4.1.818.1.1.17.3.3.1 | not-accessible | An entry containing information applicable to a particular input line.(*) | |
| NUM upsInputLineIndex_seventh | 1.3.6.1.4.1.818.1.1.17.3.3.1.1 | PositiveInteger32 | not-accessible | The input line identifier.(*) |
| NUM upsInputFrequency_seventh | 1.3.6.1.4.1.818.1.1.17.3.3.1.2 | NonNegativeInteger32 | read-only | The present input frequency.(*) |
| NUM upsInputVoltage_seventh | 1.3.6.1.4.1.818.1.1.17.3.3.1.3 | NonNegativeInteger32 | read-only | The magnitude of the present input voltage.(*) |
| NUM upsInputCurrent_seventh | 1.3.6.1.4.1.818.1.1.17.3.3.1.4 | NonNegativeInteger32 | read-only | The magnitude of the present input current.(*) |
| NUM upsInputTruePower_seventh | 1.3.6.1.4.1.818.1.1.17.3.3.1.5 | NonNegativeInteger32 | read-only | The magnitude of the present input true power.(*) |
| NUM upsInputVoltageMin_seventh | 1.3.6.1.4.1.818.1.1.17.3.3.1.6 | NonNegativeInteger32 | read-only | The lowest magnitude of the input voltage since last read out. |
| NUM upsInputVoltageMax_seventh | 1.3.6.1.4.1.818.1.1.17.3.3.1.7 | NonNegativeInteger32 | read-only | The highest magnitude of the input voltage since last read out. |
| upsOutput_seventh | 1.3.6.1.4.1.818.1.1.17.4 | |||
| INT upsOutputSource_seventh | 1.3.6.1.4.1.818.1.1.17.4.1 | INTEGER | read-only | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.(*) |
| NUM upsOutputFrequency_seventh | 1.3.6.1.4.1.818.1.1.17.4.2 | NonNegativeInteger32 | read-only | The present output frequency.(*) |
| NUM upsOutputNumLines_seventh | 1.3.6.1.4.1.818.1.1.17.4.3 | NonNegativeInteger32 | read-only | The number of output lines utilized in this device. This variable indicates the number of rows in the output table.(*) |
| upsOutputTable_seventh | 1.3.6.1.4.1.818.1.1.17.4.4 | not-accessible | A list of output table entries. The number of entries is given by the value of upsOutputNumLines.(*) | |
| upsOutputEntry_seventh | 1.3.6.1.4.1.818.1.1.17.4.4.1 | not-accessible | An entry containing information applicable to a particular output line.(*) | |
| NUM upsOutputLineIndex_seventh | 1.3.6.1.4.1.818.1.1.17.4.4.1.1 | PositiveInteger32 | not-accessible | The output line identifier.(*) |
| NUM upsOutputVoltage_seventh | 1.3.6.1.4.1.818.1.1.17.4.4.1.2 | NonNegativeInteger32 | read-only | The present output voltage.(*) |
| NUM upsOutputCurrent_seventh | 1.3.6.1.4.1.818.1.1.17.4.4.1.3 | NonNegativeInteger32 | read-only | The present output current.(*) |
| NUM upsOutputPower_seventh | 1.3.6.1.4.1.818.1.1.17.4.4.1.4 | NonNegativeInteger32 | read-only | The present output true power.(*) |
| I32 upsOutputPercentLoad_seventh | 1.3.6.1.4.1.818.1.1.17.4.4.1.5 | Integer32 | read-only | The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.(*) |
| upsBypass_seventh | 1.3.6.1.4.1.818.1.1.17.5 | |||
| NUM upsBypassFrequency_seventh | 1.3.6.1.4.1.818.1.1.17.5.1 | NonNegativeInteger32 | read-only | The present bypass frequency.(*) |
| NUM upsBypassNumLines_seventh | 1.3.6.1.4.1.818.1.1.17.5.2 | NonNegativeInteger32 | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.(*) |
| upsBypassTable_seventh | 1.3.6.1.4.1.818.1.1.17.5.3 | not-accessible | A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.(*) | |
| upsBypassEntry_seventh | 1.3.6.1.4.1.818.1.1.17.5.3.1 | not-accessible | An entry containing information applicable to a particular bypass input.(*) | |
| NUM upsBypassLineIndex_seventh | 1.3.6.1.4.1.818.1.1.17.5.3.1.1 | PositiveInteger32 | not-accessible | The bypass line identifier.(*) |
| NUM upsBypassVoltage_seventh | 1.3.6.1.4.1.818.1.1.17.5.3.1.2 | NonNegativeInteger32 | read-only | The present bypass voltage.(*) |
| NUM upsBypassCurrent_seventh | 1.3.6.1.4.1.818.1.1.17.5.3.1.3 | NonNegativeInteger32 | read-only | The present bypass current.(*) |
| NUM upsBypassPower_seventh | 1.3.6.1.4.1.818.1.1.17.5.3.1.4 | NonNegativeInteger32 | read-only | The present true power conveyed by the bypass.(*) |
| upsAlarm_seventh | 1.3.6.1.4.1.818.1.1.17.6 | |||
| G32 upsAlarmsPresent_seventh | 1.3.6.1.4.1.818.1.1.17.6.1 | Gauge32 | read-only | The present number of active alarm conditions.(*) |
| upsAlarmTable_seventh | 1.3.6.1.4.1.818.1.1.17.6.2 | not-accessible | A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent.(*) | |
| upsAlarmEntry_seventh | 1.3.6.1.4.1.818.1.1.17.6.2.1 | not-accessible | An entry containing information applicable to a particular alarm.(*) | |
| NUM upsAlarmId_seventh | 1.3.6.1.4.1.818.1.1.17.6.2.1.1 | PositiveInteger32 | not-accessible | A unique identifier for an alarm condition. This value must remain constant.(*) |
| OID upsAlarmDescr_seventh | 1.3.6.1.4.1.818.1.1.17.6.2.1.2 | AutonomousType | read-only | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.(*) |
| TIM upsAlarmTime_seventh | 1.3.6.1.4.1.818.1.1.17.6.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.(*) |
| upsWellKnownAlarms_seventh | 1.3.6.1.4.1.818.1.1.17.6.3 | |||
| upsAlarmBatteryBad_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.1 | One or more batteries have been determined to require replacement.(*) | ||
| upsAlarmOnBattery_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.2 | The UPS is drawing power from the batteries.(*) | ||
| upsAlarmLowBattery_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime.(*) | ||
| upsAlarmDepletedBattery_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.4 | The UPS will be unable to sustain the present load when and if the utility power is lost.(*) | ||
| upsAlarmTempBad_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.5 | A temperature is out of tolerance.(*) | ||
| upsAlarmInputBad_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.6 | An input condition is out of tolerance.(*) | ||
| upsAlarmOutputBad_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.7 | An output condition (other than OutputOverload) is out of tolerance.(*) | ||
| upsAlarmOutputOverload_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.8 | The output load exceeds the UPS output capacity.(*) | ||
| upsAlarmOnBypass_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.9 | The Bypass is presently engaged on the UPS.(*) | ||
| upsAlarmBypassBad_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.10 | The Bypass is out of tolerance.(*) | ||
| upsAlarmOutputOffAsRequested_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.11 | The UPS has shutdown as requested, i.e., the output is off.(*) | ||
| upsAlarmUpsOffAsRequested_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.12 | The entire UPS has shutdown as commanded.(*) | ||
| upsAlarmChargerFailed_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.13 | An uncorrected problem has been detected within the UPS charger subsystem.(*) | ||
| upsAlarmUpsOutputOff_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.14 | The output of the UPS is in the off state.(*) | ||
| upsAlarmUpsSystemOff_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.15 | The UPS system is in the off state.(*) | ||
| upsAlarmFanFailure_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.16 | The failure of one or more fans in the UPS has been detected.(*) | ||
| upsAlarmFuseFailure_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.17 | The failure of one or more fuses has been detected.(*) | ||
| upsAlarmGeneralFault_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.18 | A general fault in the UPS has been detected.(*) | ||
| upsAlarmDiagnosticTestFailed_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.19 | The result of the last diagnostic test indicates a failure.(*) | ||
| upsAlarmCommunicationsLost_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.20 | A problem has been encountered in the communications between the agent and the UPS.(*) | ||
| upsAlarmAwaitingPower_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.21 | The UPS output is off and the UPS is awaiting the return of input power.(*) | ||
| upsAlarmShutdownPending_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.22 | A upsShutdownAfterDelay countdown is underway.(*) | ||
| upsAlarmShutdownImminent_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.(*) | ||
| upsAlarmTestInProgress_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY.(*) | ||
| upsAlarmReceptacleOff_seventh | 1.3.6.1.4.1.818.1.1.17.6.3.25 | The receptacle are switch off | ||
| NUM upsAlarmMaskA_seventh | 1.3.6.1.4.1.818.1.1.17.6.4 | NonNegativeInteger32 | read-only | Specifies which alarm can be handled by the UPS. The 'Mask' parameter is a Long Integer32. The meaning of every bit is the same as for the 'upsAlarmGroupA' command. A bit having value=1 indicates that the corresponding alarm is handled by the UPS. |
| upsTest_seventh | 1.3.6.1.4.1.818.1.1.17.7 | |||
| OID upsTestId_seventh | 1.3.6.1.4.1.818.1.1.17.7.1 | OBJECT IDENTIFIER | read-write | The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned.(*) |
| TES upsTestSpinLock_seventh | 1.3.6.1.4.1.818.1.1.17.7.2 | TestAndIncr | read-write | A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try-again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock-value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock-value, upsTestId = requested-test) if (error-index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try-again } if (error-index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by polling upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock-value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1.(*) |
| INT upsTestResultsSummary_seventh | 1.3.6.1.4.1.818.1.1.17.7.3 | INTEGER | read-only | The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.(*) |
| STR upsTestResultsDetail_seventh | 1.3.6.1.4.1.818.1.1.17.7.4 | DisplayString | read-only | Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned.(*) |
| TIM upsTestStartTime_seventh | 1.3.6.1.4.1.818.1.1.17.7.5 | TimeStamp | read-only | The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0.(*) |
| NUM upsTestElapsedTime_seventh | 1.3.6.1.4.1.818.1.1.17.7.6 | TimeInterval | read-only | The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0.(*) |
| upsWellKnownTests_seventh | 1.3.6.1.4.1.818.1.1.17.7.7 | |||
| upsTestNoTestsInitiated_seventh | 1.3.6.1.4.1.818.1.1.17.7.7.1 | No tests have been initiated and no test is in progress.(*) | ||
| upsTestAbortTestInProgress_seventh | 1.3.6.1.4.1.818.1.1.17.7.7.2 | The test in progress is to be aborted / the test in progress was aborted.(*) | ||
| upsTestGeneralSystemsTest_seventh | 1.3.6.1.4.1.818.1.1.17.7.7.3 | The manufacturer's standard test of UPS device systems.(*) | ||
| upsTestQuickBatteryTest_seventh | 1.3.6.1.4.1.818.1.1.17.7.7.4 | A test that is sufficient to determine if the battery needs replacement.(*) | ||
| upsTestDeepBatteryCalibration_seventh | 1.3.6.1.4.1.818.1.1.17.7.7.5 | The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load.(*) | ||
| upsControl_seventh | 1.3.6.1.4.1.818.1.1.17.8 | |||
| INT upsShutdownType_seventh | 1.3.6.1.4.1.818.1.1.17.8.1 | INTEGER | read-write | This object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.(*) |
| I32 upsShutdownAfterDelay_seventh | 1.3.6.1.4.1.818.1.1.17.8.2 | Integer32 | read-write | Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.(*) |
| I32 upsStartupAfterDelay_seventh | 1.3.6.1.4.1.818.1.1.17.8.3 | Integer32 | read-write | Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.(*) |
| I32 upsRebootWithDuration_seventh | 1.3.6.1.4.1.818.1.1.17.8.4 | Integer32 | read-write | Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.(*) |
| INT upsAutoRestart_seventh | 1.3.6.1.4.1.818.1.1.17.8.5 | INTEGER | read-write | Setting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutdownAfterDelay or an internal battery depleted condition. Setting this object to 'off' will prevent the UPS system from restarting after a shutdown until an operator manually or remotely explicitly restarts it. If the UPS is in a startup or reboot countdown, then the UPS will not restart until that delay has been satisfied.(*) |
| NUM upsReceptaclesNum_seventh | 1.3.6.1.4.1.818.1.1.17.8.6 | NonNegativeInteger32 | read-only | The number of receptacles utilized in this device. This entry indicates the number of rows in the receptacle table. |
| upsReceptacleTable_seventh | 1.3.6.1.4.1.818.1.1.17.8.7 | not-accessible | A list of receptacle table entries. The number of entries is given by the value of upsReceptacleNum. | |
| upsReceptacleEntry_seventh | 1.3.6.1.4.1.818.1.1.17.8.7.1 | not-accessible | An entry containing information applicable to a particular receptacle. | |
| NUM upsReceptacleLineIndex_seventh | 1.3.6.1.4.1.818.1.1.17.8.7.1.1 | PositiveInteger32 | not-accessible | The receptacle line identifier. |
| INT upsReceptacleOnOff_seventh | 1.3.6.1.4.1.818.1.1.17.8.7.1.2 | INTEGER | read-write | The present state of the receptacle. Setting this object to 'on' will cause the receptacle to be turned on. Setting this object to 'off' will turn the receptacle off. If the receptacle is already in the desired state nothing will happen. After an autorestart (see upsAutoRestart) the receptacle will be on. |
| INT upsUPSMode_seventh | 1.3.6.1.4.1.818.1.1.17.8.8 | INTEGER | read-write | The operation mode off the UPS. Off-line indicates a mode in which the input power is transferred to the output directly or via a step-up or step-down transformer. On-line mode indicates a mode in which the output power is regenerated through some convertor. the operating mode of the UPS may be fixed, or may be selectable (e.g. an on-line UPS with ecomode) |
| INT upsRectifierOnOff_seventh | 1.3.6.1.4.1.818.1.1.17.8.9 | INTEGER | read-write | The present state of the rectifier. Setting this object to 'on' will cause the rectifier to be turned on. Setting this object to 'off' will turn the rectifier off. If the rectifier is already in the desired state nothing will happen. |
| INT upsBatteryChargeMethod_seventh | 1.3.6.1.4.1.818.1.1.17.8.10 | INTEGER | read-write | The present state of the charge method. Setting this object to 'Normal charge' will cause the battery to be charged using the normal method. Setting this object to 'Boost charge' will charge the battery in boost mode. If the charge method is already in the desired state nothing will happen. |
| INT upsInverterOnOff_seventh | 1.3.6.1.4.1.818.1.1.17.8.11 | INTEGER | read-write | The present state of the inverter. Setting this object to 'on' will cause the inverter to be turned on. Setting this object to 'off' will turn the inverter off. If the inverter is already in the desired state nothing will happen. |
| INT upsBypassOnOff_seventh | 1.3.6.1.4.1.818.1.1.17.8.12 | INTEGER | read-write | The present state of the bypass. Setting this object to 'on' will cause the bypass to be activated. Setting this object to 'off' will deactivate the bypass. If the UPS is already in the desired state nothing will happen. |
| INT upsLoadSource_seventh | 1.3.6.1.4.1.818.1.1.17.8.13 | INTEGER | read-write | The present source of the load. Setting this object to 'On bypass' will cause the load to be supplied by the bypass. Setting this object to 'On inverter' will cause the load to be supplied by the inverter. If the load is already supplied by the desired source nothing will happen. |
| upsConfig_seventh | 1.3.6.1.4.1.818.1.1.17.9 | |||
| NUM upsConfigInputVoltage_seventh | 1.3.6.1.4.1.818.1.1.17.9.1 | NonNegativeInteger32 | read-write | The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigInputFreq_seventh | 1.3.6.1.4.1.818.1.1.17.9.2 | NonNegativeInteger32 | read-write | The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVoltage_seventh | 1.3.6.1.4.1.818.1.1.17.9.3 | NonNegativeInteger32 | read-write | The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputFreq_seventh | 1.3.6.1.4.1.818.1.1.17.9.4 | NonNegativeInteger32 | read-write | The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVA_seventh | 1.3.6.1.4.1.818.1.1.17.9.5 | NonNegativeInteger32 | read-only | The magnitude of the nominal Volt-Amp rating.(*) |
| NUM upsConfigOutputPower_seventh | 1.3.6.1.4.1.818.1.1.17.9.6 | NonNegativeInteger32 | read-only | The magnitude of the nominal true power rating.(*) |
| NUM upsConfigLowBattTime_seventh | 1.3.6.1.4.1.818.1.1.17.9.7 | NonNegativeInteger32 | read-write | The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.(*) |
| INT upsConfigAudibleStatus_seventh | 1.3.6.1.4.1.818.1.1.17.9.8 | INTEGER | read-write | The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.(*) |
| NUM upsConfigLowVoltageTransferPoint_seventh | 1.3.6.1.4.1.818.1.1.17.9.9 | NonNegativeInteger32 | read-write | The minimum input line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigHighVoltageTransferPoint_seventh | 1.3.6.1.4.1.818.1.1.17.9.10 | NonNegativeInteger32 | read-write | The maximum line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigBatteryCapacity_seventh | 1.3.6.1.4.1.818.1.1.17.9.11 | NonNegativeInteger32 | read-write | The installed battery capacity. This value is the 'factory'-value, not the value after calibration. |
| NUM upsConfigBatteryChargeCurrent_seventh | 1.3.6.1.4.1.818.1.1.17.9.12 | NonNegativeInteger32 | read-write | The maximum battery charge current, including external chargers. |
| INT upsConfigNoLoadShutdown_seventh | 1.3.6.1.4.1.818.1.1.17.9.13 | INTEGER | read-write | Dis- or enable 'no load' shutdown from the contact interface. |
| NUM upsConfigStartDelay_seventh | 1.3.6.1.4.1.818.1.1.17.9.14 | PositiveInteger32 | read-write | Minimum required autonomy time before the UPS may perform an autorestart. |
| upsGetSet_seventh | 1.3.6.1.4.1.818.1.1.17.10 | |||
| NUM upsEventGetNext_seventh | 1.3.6.1.4.1.818.1.1.17.10.1 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventSetStartingTimeStamp will be used as the start value of the table with the lowest index number. |
| NUM upsEventGetPrevious_seventh | 1.3.6.1.4.1.818.1.1.17.10.2 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventLastTime will be used as the last value of the table with the highest index number. Returns SNMP-NOSUCHNAME for UPSs that don't support this command. |
| NUM upsEventSetStartingTimeStamp_seventh | 1.3.6.1.4.1.818.1.1.17.10.3 | NonNegativeInteger32 | read-write | The timestamp which is used as starting point for downloading events from the UPS event buffer |
| NUM upsEventRetreiveCurrentTimeStamp_seventh | 1.3.6.1.4.1.818.1.1.17.10.4 | NonNegativeInteger32 | read-only | The current timestamp is retreived from the UPS |
| NUM upsEventTableSize_seventh | 1.3.6.1.4.1.818.1.1.17.10.5 | NonNegativeInteger32 | read-only | The number of entries in the event table. This object indicates the number of rows in the event table. |
| upsEventTable_seventh | 1.3.6.1.4.1.818.1.1.17.10.6 | not-accessible | A list of event table entries. The number of entries is always 10, and the value of upsEventTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..10)): PDU-SET upsSetStartingTimeStamp PDU-SET upsEventGetNext PDU-GET upsEventTableSize PDU-GET upsEventCode,upsEventStatus,upsEventTime 1 PDU-GET upsEventCode,upsEventStatus,upsEventTime 2 .. PDU-GET upsEventCode,upsEventStatus,upsEventTime The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsEventTableSize. | |
| upsEventEntry_seventh | 1.3.6.1.4.1.818.1.1.17.10.6.1 | not-accessible | An entry containing information applicable to a particular event. | |
| NUM upsEventLineIndex_seventh | 1.3.6.1.4.1.818.1.1.17.10.6.1.1 | PositiveInteger32 | not-accessible | The event line identifier. |
| NUM upsEventCode_seventh | 1.3.6.1.4.1.818.1.1.17.10.6.1.2 | NonNegativeInteger32 | read-only | The event code in numerical format. |
| NUM upsEventStatus_seventh | 1.3.6.1.4.1.818.1.1.17.10.6.1.3 | NonNegativeInteger32 | read-only | The status of the UPS at the moment that the event was generated. The format is specified at the 'upsStatus' command. If the UPS is not able to deliver status information, then SNMP-NOSUCHNAME is returned. |
| NUM upsEventTime_seventh | 1.3.6.1.4.1.818.1.1.17.10.6.1.4 | NonNegativeInteger32 | read-only | The timestamp of the moment the event was generated. |
| NUM upsParametersRead_seventh | 1.3.6.1.4.1.818.1.1.17.10.7 | PositiveInteger32 | read-write | The number of parameters to retreive from the UPS. When this object is set the ParameterTable will be filled with the requested number of entries. The value upsParametersStartAddress will be used as the start value of the table with the lowest index number. |
| NUM upsParametersWrite_seventh | 1.3.6.1.4.1.818.1.1.17.10.8 | PositiveInteger32 | read-write | The number of parameters to write to the UPS. When this object is set the ParameterTable will be send to the ups. The value upsParametersStartAddress will be used for the first value of the table with the lowest index number. |
| NUM upsParametersStartAddress_seventh | 1.3.6.1.4.1.818.1.1.17.10.9 | NonNegativeInteger32 | read-write | The address which is used as starting point for downloading parameters from the UPS |
| NUM upsParameterTableSize_seventh | 1.3.6.1.4.1.818.1.1.17.10.10 | NonNegativeInteger32 | read-only | The number of entries in the parameter table. This object indicates the number of rows in the parameter table. |
| upsParameterTable_seventh | 1.3.6.1.4.1.818.1.1.17.10.11 | not-accessible | A list of parameter entries. The number of entries is always 16, and the value of upsParameterTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..16)): Read sequence: PDU-SET upsSetStartingAddress PDU-SET upsParametersRead PDU-GET upsParameterTableSize PDU-GET upsParameterValue 1 PDU-GET upsParameterValue 2 .. PDU-GET upsParameterValue The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsParameterTableSize. Write sequence: PDU-SET upsSetStartingAddress PDU-SET upsParameterValue 1 PDU-SET upsParameterValue 2 .. PDU-SET upsParameterValue PDU-SET upsParametersWrite | |
| upsParameterEntry_seventh | 1.3.6.1.4.1.818.1.1.17.10.11.1 | not-accessible | An entry containing information applicable to a particular parameter. | |
| NUM upsParameterLineIndex_seventh | 1.3.6.1.4.1.818.1.1.17.10.11.1.1 | PositiveInteger32 | not-accessible | The parameter line identifier. |
| I32 upsParameterValue_seventh | 1.3.6.1.4.1.818.1.1.17.10.11.1.2 | Integer32 | read-write | The parameter value in numerical format. |
| NUM upsStatus_seventh | 1.3.6.1.4.1.818.1.1.17.10.12 | NonNegativeInteger32 | read-only | The global UPS status is returned. Every bit reflects a specific status condition. Unused bits returns as 0. The status value can also be found on other commands. The value SNMP-NOSUCHNAME means 'invalid status' or 'status value non available'. Status 1 0001h upsStatusEcomodeIsOn 2 0002h upsStatusBatteryIsCharging 4 0004h upsStatusBatteryIsDischarging 8 0008h upsStatusAlarmIsActive 16 0010h upsStatusRectifierIsOn 32 0020h upsStatusLowBattery 64 0040h upsStatusOnBypass 128 0080h upsStatusMainsBypassOK 256 0100h upsStatusMainsRectifierOK 512 0200h upsStatusDetourIsOn 1024 0400h upsStatusAcousticAlarmIsOn 2048 0800h - (not used.) 4096 1000h upsStatusInverterIsOn 8192 2000h upsStatusNotInParallel (Q1 open) 16384 4000h upsStatusResetLoadOff 32768 8000h upsStatusLoadOff |
| NUM upsMainsStatisticsMBfail_seventh | 1.3.6.1.4.1.818.1.1.17.10.13 | NonNegativeInteger32 | read-only | Count of main bypass failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsMRfail_seventh | 1.3.6.1.4.1.818.1.1.17.10.14 | NonNegativeInteger32 | read-only | Count of mains rectifier failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsB2_seventh | 1.3.6.1.4.1.818.1.1.17.10.15 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (0..2 ms), during the last 7 days. |
| NUM upsMainsStatisticsB5_seventh | 1.3.6.1.4.1.818.1.1.17.10.16 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (2..5 ms), during the last 7 days. |
| NUM upsMainsStatisticsB10_seventh | 1.3.6.1.4.1.818.1.1.17.10.17 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (5..10 ms), during the last 7 days. |
| NUM upsMainsStatisticsB200_seventh | 1.3.6.1.4.1.818.1.1.17.10.18 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (10..200 ms), during the last 7 days. |
| NUM upsMainsStatisticsBypRel_seventh | 1.3.6.1.4.1.818.1.1.17.10.19 | NonNegativeInteger32 | read-only | Bypass reliability degree [0..100%;255]. The value NOSUCHNAME means 'not available'. |
| NUM upsTime_seventh | 1.3.6.1.4.1.818.1.1.17.10.20 | NonNegativeInteger32 | read-write | The current timestamp (or real-time) of the UPS. For the format, see 'Timestamp' specifications. The write-command has to comply with the correct timestamp format expected by the UPS (counter value or real-time-clock value). Missing to doing so will result in a SNMP-seventhERROR, meaning 'command not supported'. It is possible to know which is the timestamp format supported by the UPS, by issuing a read-command or by reading events, which includes timestamps. |
| STR upsRequestPermission_seventh | 1.3.6.1.4.1.818.1.1.17.10.21 | DisplayString | write-only | An encrypted code is send to enable use of restricted write objects during a limited period of time. |
| I32 upsEventGetCode_seventh | 1.3.6.1.4.1.818.1.1.17.10.22 | Integer32 | write-only | The code which is used as starting point to downloading the events from the UPS event buffer. |
| TES upsEventSpinLock_seventh | 1.3.6.1.4.1.818.1.1.17.10.23 | TestAndIncr | read-write | A spin lock on the event subsystem. |
| TES upsParameterSpinLock_seventh | 1.3.6.1.4.1.818.1.1.17.10.24 | TestAndIncr | read-write | A spin lock on the parameters subsystem. |
| geUPSTraps_seventh | 1.3.6.1.4.1.818.1.1.17.11 | |||
| NTF upsAlarmBatteryBadTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.1 | One or more batteries have been determined to require replacement. | ||
| NTF upsAlarmOnBatteryTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.2 | An On Battery condition is restored. | ||
| NTF upsAlarmLowBatteryTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime. | ||
| NTF upsAlarmDepletedBatteryTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.4 | The UPS will be unable to sustain the present load when and if the utility power is lost) | ||
| NTF upsAlarmTempBadTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.5 | A temperature is out of tolerance. | ||
| NTF upsAlarmInputBadTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.6 | An input condition is out of tolerance. | ||
| NTF upsAlarmOutputBadTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.7 | An output condition (other than OutputOverload) is out of tolerance. | ||
| NTF upsAlarmOutputOverloadTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.8 | The output load exceeds the UPS output capacity. | ||
| NTF upsAlarmOnBypassTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.9 | The Bypass is presently engaged on the UPS. | ||
| NTF upsAlarmBypassBadTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.10 | The Bypass is out of tolerance. | ||
| NTF upsAlarmOutputOffAsRequestedTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.11 | The UPS has shutdown as requested, i.e., the output is off. | ||
| NTF upsAlarmUpsOffAsRequestedTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.12 | The entire UPS has shutdown as commanded. | ||
| NTF upsAlarmChargerFailedTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.13 | An uncorrected problem has been detected within the UPS charger subsystem. | ||
| NTF upsAlarmUpsOutputOffTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.14 | The output of the UPS is in the off state. | ||
| NTF upsAlarmUpsSystemOffTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.15 | The UPS system is in the off state. | ||
| NTF upsAlarmFanFailureTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.16 | The failure of one or more fans in the UPS has been detected. | ||
| NTF upsAlarmFuseFailureTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.17 | The failure of one or more fuses has been detected. | ||
| NTF upsAlarmGeneralFaultTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.18 | A general fault in the UPS has been detected. | ||
| NTF upsAlarmDiagnosticTestFailedTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.19 | The result of the last diagnostic test indicates a failure. | ||
| NTF upsAlarmCommunicationsLostTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.20 | A problem has been encountered in the communication between the agent and the UPS. | ||
| NTF upsAlarmAwaitingPowerTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.21 | The UPS output is off and the UPS is awaiting the return of the input power (*). | ||
| NTF upsAlarmShutdownPendingTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.22 | A upsShutdownAfterDelay countdown is underway. | ||
| NTF upsAlarmShutdownImminentTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | ||
| NTF upsAlarmTestInProgressTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | ||
| NTF upsAlarmReceptacleOffTrap_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.25 | A receptacle has been switched off. | ||
| NTF upsAlarmBatteryBadRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.33 | A Battery bad condition is restored. | ||
| NTF upsAlarmOnBatteryRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.34 | The UPS is drawing power from mains again. | ||
| NTF upsAlarmLowBatteryRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.35 | A Low Battery condition is restored. | ||
| NTF upsAlarmDepletedBatteryRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.36 | A Depleted Battery condition is restored. | ||
| NTF upsAlarmTempBadRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.37 | A bad temperature condition is restored. | ||
| NTF upsAlarmInputBadRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.38 | An input bad condition is restored. | ||
| NTF upsAlarmOutputBadRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.39 | An output bad condition is restored. | ||
| NTF upsAlarmOutputOverloadRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.40 | An output overload condition is restored. | ||
| NTF upsAlarmOnBypassRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.41 | An On Bypass condition is restored. | ||
| NTF upsAlarmBypassBadRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.42 | A Bypass bad condition is restored. | ||
| NTF upsAlarmOutputOffAsRequestedRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.43 | A request shutdown has been restored. | ||
| NTF upsAlarmUpsOffAsRequestedRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.44 | A entire UPS command has been restored. | ||
| NTF upsAlarmChargerFailedRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.45 | A Charger Failer condition is restored. | ||
| NTF upsAlarmUpsOutputOn_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.46 | The output of the UPS switched in the on state. | ||
| NTF upsAlarmUpsSystemOn_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.47 | The UPS system is switched in the on state. | ||
| NTF upsAlarmFanFailureRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.48 | A Fan failure condition is restored. | ||
| NTF upsAlarmFuseFailureRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.49 | A Fuse failure condition is restored. | ||
| NTF upsAlarmGeneralFaultRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.50 | A general fault is restored. | ||
| NTF upsAlarmDiagnosticTestFailedRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.51 | A last diagnostic test indicates a failure is restored. | ||
| NTF upsAlarmCommunicationsLostRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.52 | A problem in the communication between the agent and the UPS is restored. | ||
| NTF upsAlarmAwaitingPowerRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.53 | A awaiting power condition is restored (*). | ||
| NTF upsAlarmShutdownPendingRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.54 | A upsShutdownAfterDelay countdown is restored. | ||
| NTF upsAlarmShutdownImminentRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.55 | A shutdown imminent condition is restored. | ||
| NTF upsAlarmTestInProgressRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.56 | The test is in progress is terminated. | ||
| NTF upsAlarmReceptacleOn_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.57 | A receptacle has been switched on. | ||
| NTF upsAlarmValueLow_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.129 | A measurement value reached a value below its low-level threshold. | ||
| NTF upsAlarmValueHigh_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.130 | A measurement value reached a value higher than its high-level threshold. | ||
| NTF upsAlarmValueLowRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.133 | A ValueLow alarm condition is restored. | ||
| NTF upsAlarmValueHighRestored_seventh | 1.3.6.1.4.1.818.1.1.17.11.0.134 | A ValueHigh alarm condition is restored. | ||
| geEighthUPS | 1.3.6.1.4.1.818.1.1.18 | |||
| upsIdent_eighth | 1.3.6.1.4.1.818.1.1.18.1 | |||
| STR upsIdentManufacturer_eighth | 1.3.6.1.4.1.818.1.1.18.1.1 | DisplayString | read-only | The name of the UPS manufacturer.(*) |
| STR upsIdentModel_eighth | 1.3.6.1.4.1.818.1.1.18.1.2 | DisplayString | read-only | The UPS Model designation.(*) |
| STR upsIdentUPSSoftwareVersion_eighth | 1.3.6.1.4.1.818.1.1.18.1.3 | DisplayString | read-only | The UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.(*) |
| STR upsIdentAgentSoftwareVersion_eighth | 1.3.6.1.4.1.818.1.1.18.1.4 | DisplayString | read-only | The UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.(*) |
| STR upsIdentName_eighth | 1.3.6.1.4.1.818.1.1.18.1.5 | DisplayString | read-write | A string identifying the UPS. This object should be set by the administrator.(*) |
| STR upsIdentAttachedDevices_eighth | 1.3.6.1.4.1.818.1.1.18.1.6 | DisplayString | read-write | A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.(*) |
| STR upsIdentUPSSerialNumber_eighth | 1.3.6.1.4.1.818.1.1.18.1.7 | DisplayString | read-only | The UPS serial number |
| STR upsIdentComProtVersion_eighth | 1.3.6.1.4.1.818.1.1.18.1.8 | DisplayString | read-only | The IMV communication protocol version |
| NUM upsIdentOperatingTime_eighth | 1.3.6.1.4.1.818.1.1.18.1.9 | NonNegativeInteger32 | read-only | The present value of the operating time. total 'on' time since UPS manufactured |
| upsBattery_eighth | 1.3.6.1.4.1.818.1.1.18.2 | |||
| INT upsBatteryStatus_eighth | 1.3.6.1.4.1.818.1.1.18.2.1 | INTEGER | read-only | The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).(*) |
| NUM upsSecondsOnBattery_eighth | 1.3.6.1.4.1.818.1.1.18.2.2 | NonNegativeInteger32 | read-only | If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.(*) |
| NUM upsEstimatedMinutesRemaining_eighth | 1.3.6.1.4.1.818.1.1.18.2.3 | PositiveInteger32 | read-only | An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.(*) |
| I32 upsEstimatedChargeRemaining_eighth | 1.3.6.1.4.1.818.1.1.18.2.4 | Integer32 | read-only | An estimate of the battery charge remaining expressed as a percent of full charge.(*) |
| NUM upsBatteryVoltage_eighth | 1.3.6.1.4.1.818.1.1.18.2.5 | NonNegativeInteger32 | read-only | The magnitude of the present battery voltage.(*) |
| I32 upsBatteryCurrent_eighth | 1.3.6.1.4.1.818.1.1.18.2.6 | Integer32 | read-only | The present battery current.(*) |
| I32 upsBatteryTemperature_eighth | 1.3.6.1.4.1.818.1.1.18.2.7 | Integer32 | read-only | The ambient temperature at or near the UPS Battery casing.(*) |
| upsInput_eighth | 1.3.6.1.4.1.818.1.1.18.3 | |||
| C32 upsInputLineBads_eighth | 1.3.6.1.4.1.818.1.1.18.3.1 | Counter32 | read-only | A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.(*) |
| NUM upsInputNumLines_eighth | 1.3.6.1.4.1.818.1.1.18.3.2 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This variable indicates the number of rows in the input table.(*) |
| upsInputTable_eighth | 1.3.6.1.4.1.818.1.1.18.3.3 | not-accessible | A list of input table entries. The number of entries is given by the value of upsInputNumLines.(*) | |
| upsInputEntry_eighth | 1.3.6.1.4.1.818.1.1.18.3.3.1 | not-accessible | An entry containing information applicable to a particular input line.(*) | |
| NUM upsInputLineIndex_eighth | 1.3.6.1.4.1.818.1.1.18.3.3.1.1 | PositiveInteger32 | not-accessible | The input line identifier.(*) |
| NUM upsInputFrequency_eighth | 1.3.6.1.4.1.818.1.1.18.3.3.1.2 | NonNegativeInteger32 | read-only | The present input frequency.(*) |
| NUM upsInputVoltage_eighth | 1.3.6.1.4.1.818.1.1.18.3.3.1.3 | NonNegativeInteger32 | read-only | The magnitude of the present input voltage.(*) |
| NUM upsInputCurrent_eighth | 1.3.6.1.4.1.818.1.1.18.3.3.1.4 | NonNegativeInteger32 | read-only | The magnitude of the present input current.(*) |
| NUM upsInputTruePower_eighth | 1.3.6.1.4.1.818.1.1.18.3.3.1.5 | NonNegativeInteger32 | read-only | The magnitude of the present input true power.(*) |
| NUM upsInputVoltageMin_eighth | 1.3.6.1.4.1.818.1.1.18.3.3.1.6 | NonNegativeInteger32 | read-only | The lowest magnitude of the input voltage since last read out. |
| NUM upsInputVoltageMax_eighth | 1.3.6.1.4.1.818.1.1.18.3.3.1.7 | NonNegativeInteger32 | read-only | The highest magnitude of the input voltage since last read out. |
| upsOutput_eighth | 1.3.6.1.4.1.818.1.1.18.4 | |||
| INT upsOutputSource_eighth | 1.3.6.1.4.1.818.1.1.18.4.1 | INTEGER | read-only | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.(*) |
| NUM upsOutputFrequency_eighth | 1.3.6.1.4.1.818.1.1.18.4.2 | NonNegativeInteger32 | read-only | The present output frequency.(*) |
| NUM upsOutputNumLines_eighth | 1.3.6.1.4.1.818.1.1.18.4.3 | NonNegativeInteger32 | read-only | The number of output lines utilized in this device. This variable indicates the number of rows in the output table.(*) |
| upsOutputTable_eighth | 1.3.6.1.4.1.818.1.1.18.4.4 | not-accessible | A list of output table entries. The number of entries is given by the value of upsOutputNumLines.(*) | |
| upsOutputEntry_eighth | 1.3.6.1.4.1.818.1.1.18.4.4.1 | not-accessible | An entry containing information applicable to a particular output line.(*) | |
| NUM upsOutputLineIndex_eighth | 1.3.6.1.4.1.818.1.1.18.4.4.1.1 | PositiveInteger32 | not-accessible | The output line identifier.(*) |
| NUM upsOutputVoltage_eighth | 1.3.6.1.4.1.818.1.1.18.4.4.1.2 | NonNegativeInteger32 | read-only | The present output voltage.(*) |
| NUM upsOutputCurrent_eighth | 1.3.6.1.4.1.818.1.1.18.4.4.1.3 | NonNegativeInteger32 | read-only | The present output current.(*) |
| NUM upsOutputPower_eighth | 1.3.6.1.4.1.818.1.1.18.4.4.1.4 | NonNegativeInteger32 | read-only | The present output true power.(*) |
| I32 upsOutputPercentLoad_eighth | 1.3.6.1.4.1.818.1.1.18.4.4.1.5 | Integer32 | read-only | The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.(*) |
| upsBypass_eighth | 1.3.6.1.4.1.818.1.1.18.5 | |||
| NUM upsBypassFrequency_eighth | 1.3.6.1.4.1.818.1.1.18.5.1 | NonNegativeInteger32 | read-only | The present bypass frequency.(*) |
| NUM upsBypassNumLines_eighth | 1.3.6.1.4.1.818.1.1.18.5.2 | NonNegativeInteger32 | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.(*) |
| upsBypassTable_eighth | 1.3.6.1.4.1.818.1.1.18.5.3 | not-accessible | A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.(*) | |
| upsBypassEntry_eighth | 1.3.6.1.4.1.818.1.1.18.5.3.1 | not-accessible | An entry containing information applicable to a particular bypass input.(*) | |
| NUM upsBypassLineIndex_eighth | 1.3.6.1.4.1.818.1.1.18.5.3.1.1 | PositiveInteger32 | not-accessible | The bypass line identifier.(*) |
| NUM upsBypassVoltage_eighth | 1.3.6.1.4.1.818.1.1.18.5.3.1.2 | NonNegativeInteger32 | read-only | The present bypass voltage.(*) |
| NUM upsBypassCurrent_eighth | 1.3.6.1.4.1.818.1.1.18.5.3.1.3 | NonNegativeInteger32 | read-only | The present bypass current.(*) |
| NUM upsBypassPower_eighth | 1.3.6.1.4.1.818.1.1.18.5.3.1.4 | NonNegativeInteger32 | read-only | The present true power conveyed by the bypass.(*) |
| upsAlarm_eighth | 1.3.6.1.4.1.818.1.1.18.6 | |||
| G32 upsAlarmsPresent_eighth | 1.3.6.1.4.1.818.1.1.18.6.1 | Gauge32 | read-only | The present number of active alarm conditions.(*) |
| upsAlarmTable_eighth | 1.3.6.1.4.1.818.1.1.18.6.2 | not-accessible | A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent.(*) | |
| upsAlarmEntry_eighth | 1.3.6.1.4.1.818.1.1.18.6.2.1 | not-accessible | An entry containing information applicable to a particular alarm.(*) | |
| NUM upsAlarmId_eighth | 1.3.6.1.4.1.818.1.1.18.6.2.1.1 | PositiveInteger32 | not-accessible | A unique identifier for an alarm condition. This value must remain constant.(*) |
| OID upsAlarmDescr_eighth | 1.3.6.1.4.1.818.1.1.18.6.2.1.2 | AutonomousType | read-only | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.(*) |
| TIM upsAlarmTime_eighth | 1.3.6.1.4.1.818.1.1.18.6.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.(*) |
| upsWellKnownAlarms_eighth | 1.3.6.1.4.1.818.1.1.18.6.3 | |||
| upsAlarmBatteryBad_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.1 | One or more batteries have been determined to require replacement.(*) | ||
| upsAlarmOnBattery_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.2 | The UPS is drawing power from the batteries.(*) | ||
| upsAlarmLowBattery_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime.(*) | ||
| upsAlarmDepletedBattery_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.4 | The UPS will be unable to sustain the present load when and if the utility power is lost.(*) | ||
| upsAlarmTempBad_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.5 | A temperature is out of tolerance.(*) | ||
| upsAlarmInputBad_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.6 | An input condition is out of tolerance.(*) | ||
| upsAlarmOutputBad_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.7 | An output condition (other than OutputOverload) is out of tolerance.(*) | ||
| upsAlarmOutputOverload_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.8 | The output load exceeds the UPS output capacity.(*) | ||
| upsAlarmOnBypass_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.9 | The Bypass is presently engaged on the UPS.(*) | ||
| upsAlarmBypassBad_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.10 | The Bypass is out of tolerance.(*) | ||
| upsAlarmOutputOffAsRequested_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.11 | The UPS has shutdown as requested, i.e., the output is off.(*) | ||
| upsAlarmUpsOffAsRequested_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.12 | The entire UPS has shutdown as commanded.(*) | ||
| upsAlarmChargerFailed_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.13 | An uncorrected problem has been detected within the UPS charger subsystem.(*) | ||
| upsAlarmUpsOutputOff_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.14 | The output of the UPS is in the off state.(*) | ||
| upsAlarmUpsSystemOff_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.15 | The UPS system is in the off state.(*) | ||
| upsAlarmFanFailure_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.16 | The failure of one or more fans in the UPS has been detected.(*) | ||
| upsAlarmFuseFailure_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.17 | The failure of one or more fuses has been detected.(*) | ||
| upsAlarmGeneralFault_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.18 | A general fault in the UPS has been detected.(*) | ||
| upsAlarmDiagnosticTestFailed_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.19 | The result of the last diagnostic test indicates a failure.(*) | ||
| upsAlarmCommunicationsLost_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.20 | A problem has been encountered in the communications between the agent and the UPS.(*) | ||
| upsAlarmAwaitingPower_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.21 | The UPS output is off and the UPS is awaiting the return of input power.(*) | ||
| upsAlarmShutdownPending_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.22 | A upsShutdownAfterDelay countdown is underway.(*) | ||
| upsAlarmShutdownImminent_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.(*) | ||
| upsAlarmTestInProgress_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY.(*) | ||
| upsAlarmReceptacleOff_eighth | 1.3.6.1.4.1.818.1.1.18.6.3.25 | The receptacle are switch off | ||
| NUM upsAlarmMaskA_eighth | 1.3.6.1.4.1.818.1.1.18.6.4 | NonNegativeInteger32 | read-only | Specifies which alarm can be handled by the UPS. The 'Mask' parameter is a Long Integer32. The meaning of every bit is the same as for the 'upsAlarmGroupA' command. A bit having value=1 indicates that the corresponding alarm is handled by the UPS. |
| upsTest_eighth | 1.3.6.1.4.1.818.1.1.18.7 | |||
| OID upsTestId_eighth | 1.3.6.1.4.1.818.1.1.18.7.1 | OBJECT IDENTIFIER | read-write | The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned.(*) |
| TES upsTestSpinLock_eighth | 1.3.6.1.4.1.818.1.1.18.7.2 | TestAndIncr | read-write | A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try-again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock-value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock-value, upsTestId = requested-test) if (error-index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try-again } if (error-index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by polling upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock-value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1.(*) |
| INT upsTestResultsSummary_eighth | 1.3.6.1.4.1.818.1.1.18.7.3 | INTEGER | read-only | The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.(*) |
| STR upsTestResultsDetail_eighth | 1.3.6.1.4.1.818.1.1.18.7.4 | DisplayString | read-only | Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned.(*) |
| TIM upsTestStartTime_eighth | 1.3.6.1.4.1.818.1.1.18.7.5 | TimeStamp | read-only | The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0.(*) |
| NUM upsTestElapsedTime_eighth | 1.3.6.1.4.1.818.1.1.18.7.6 | TimeInterval | read-only | The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0.(*) |
| upsWellKnownTests_eighth | 1.3.6.1.4.1.818.1.1.18.7.7 | |||
| upsTestNoTestsInitiated_eighth | 1.3.6.1.4.1.818.1.1.18.7.7.1 | No tests have been initiated and no test is in progress.(*) | ||
| upsTestAbortTestInProgress_eighth | 1.3.6.1.4.1.818.1.1.18.7.7.2 | The test in progress is to be aborted / the test in progress was aborted.(*) | ||
| upsTestGeneralSystemsTest_eighth | 1.3.6.1.4.1.818.1.1.18.7.7.3 | The manufacturer's standard test of UPS device systems.(*) | ||
| upsTestQuickBatteryTest_eighth | 1.3.6.1.4.1.818.1.1.18.7.7.4 | A test that is sufficient to determine if the battery needs replacement.(*) | ||
| upsTestDeepBatteryCalibration_eighth | 1.3.6.1.4.1.818.1.1.18.7.7.5 | The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load.(*) | ||
| upsControl_eighth | 1.3.6.1.4.1.818.1.1.18.8 | |||
| INT upsShutdownType_eighth | 1.3.6.1.4.1.818.1.1.18.8.1 | INTEGER | read-write | This object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.(*) |
| I32 upsShutdownAfterDelay_eighth | 1.3.6.1.4.1.818.1.1.18.8.2 | Integer32 | read-write | Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.(*) |
| I32 upsStartupAfterDelay_eighth | 1.3.6.1.4.1.818.1.1.18.8.3 | Integer32 | read-write | Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.(*) |
| I32 upsRebootWithDuration_eighth | 1.3.6.1.4.1.818.1.1.18.8.4 | Integer32 | read-write | Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.(*) |
| INT upsAutoRestart_eighth | 1.3.6.1.4.1.818.1.1.18.8.5 | INTEGER | read-write | Setting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutdownAfterDelay or an internal battery depleted condition. Setting this object to 'off' will prevent the UPS system from restarting after a shutdown until an operator manually or remotely explicitly restarts it. If the UPS is in a startup or reboot countdown, then the UPS will not restart until that delay has been satisfied.(*) |
| NUM upsReceptaclesNum_eighth | 1.3.6.1.4.1.818.1.1.18.8.6 | NonNegativeInteger32 | read-only | The number of receptacles utilized in this device. This entry indicates the number of rows in the receptacle table. |
| upsReceptacleTable_eighth | 1.3.6.1.4.1.818.1.1.18.8.7 | not-accessible | A list of receptacle table entries. The number of entries is given by the value of upsReceptacleNum. | |
| upsReceptacleEntry_eighth | 1.3.6.1.4.1.818.1.1.18.8.7.1 | not-accessible | An entry containing information applicable to a particular receptacle. | |
| NUM upsReceptacleLineIndex_eighth | 1.3.6.1.4.1.818.1.1.18.8.7.1.1 | PositiveInteger32 | not-accessible | The receptacle line identifier. |
| INT upsReceptacleOnOff_eighth | 1.3.6.1.4.1.818.1.1.18.8.7.1.2 | INTEGER | read-write | The present state of the receptacle. Setting this object to 'on' will cause the receptacle to be turned on. Setting this object to 'off' will turn the receptacle off. If the receptacle is already in the desired state nothing will happen. After an autorestart (see upsAutoRestart) the receptacle will be on. |
| INT upsUPSMode_eighth | 1.3.6.1.4.1.818.1.1.18.8.8 | INTEGER | read-write | The operation mode off the UPS. Off-line indicates a mode in which the input power is transferred to the output directly or via a step-up or step-down transformer. On-line mode indicates a mode in which the output power is regenerated through some convertor. the operating mode of the UPS may be fixed, or may be selectable (e.g. an on-line UPS with ecomode) |
| INT upsRectifierOnOff_eighth | 1.3.6.1.4.1.818.1.1.18.8.9 | INTEGER | read-write | The present state of the rectifier. Setting this object to 'on' will cause the rectifier to be turned on. Setting this object to 'off' will turn the rectifier off. If the rectifier is already in the desired state nothing will happen. |
| INT upsBatteryChargeMethod_eighth | 1.3.6.1.4.1.818.1.1.18.8.10 | INTEGER | read-write | The present state of the charge method. Setting this object to 'Normal charge' will cause the battery to be charged using the normal method. Setting this object to 'Boost charge' will charge the battery in boost mode. If the charge method is already in the desired state nothing will happen. |
| INT upsInverterOnOff_eighth | 1.3.6.1.4.1.818.1.1.18.8.11 | INTEGER | read-write | The present state of the inverter. Setting this object to 'on' will cause the inverter to be turned on. Setting this object to 'off' will turn the inverter off. If the inverter is already in the desired state nothing will happen. |
| INT upsBypassOnOff_eighth | 1.3.6.1.4.1.818.1.1.18.8.12 | INTEGER | read-write | The present state of the bypass. Setting this object to 'on' will cause the bypass to be activated. Setting this object to 'off' will deactivate the bypass. If the UPS is already in the desired state nothing will happen. |
| INT upsLoadSource_eighth | 1.3.6.1.4.1.818.1.1.18.8.13 | INTEGER | read-write | The present source of the load. Setting this object to 'On bypass' will cause the load to be supplied by the bypass. Setting this object to 'On inverter' will cause the load to be supplied by the inverter. If the load is already supplied by the desired source nothing will happen. |
| upsConfig_eighth | 1.3.6.1.4.1.818.1.1.18.9 | |||
| NUM upsConfigInputVoltage_eighth | 1.3.6.1.4.1.818.1.1.18.9.1 | NonNegativeInteger32 | read-write | The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigInputFreq_eighth | 1.3.6.1.4.1.818.1.1.18.9.2 | NonNegativeInteger32 | read-write | The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVoltage_eighth | 1.3.6.1.4.1.818.1.1.18.9.3 | NonNegativeInteger32 | read-write | The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputFreq_eighth | 1.3.6.1.4.1.818.1.1.18.9.4 | NonNegativeInteger32 | read-write | The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*) |
| NUM upsConfigOutputVA_eighth | 1.3.6.1.4.1.818.1.1.18.9.5 | NonNegativeInteger32 | read-only | The magnitude of the nominal Volt-Amp rating.(*) |
| NUM upsConfigOutputPower_eighth | 1.3.6.1.4.1.818.1.1.18.9.6 | NonNegativeInteger32 | read-only | The magnitude of the nominal true power rating.(*) |
| NUM upsConfigLowBattTime_eighth | 1.3.6.1.4.1.818.1.1.18.9.7 | NonNegativeInteger32 | read-write | The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.(*) |
| INT upsConfigAudibleStatus_eighth | 1.3.6.1.4.1.818.1.1.18.9.8 | INTEGER | read-write | The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.(*) |
| NUM upsConfigLowVoltageTransferPoint_eighth | 1.3.6.1.4.1.818.1.1.18.9.9 | NonNegativeInteger32 | read-write | The minimum input line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigHighVoltageTransferPoint_eighth | 1.3.6.1.4.1.818.1.1.18.9.10 | NonNegativeInteger32 | read-write | The maximum line voltage allowed before the UPS system transfers to battery backup.(*) |
| NUM upsConfigBatteryCapacity_eighth | 1.3.6.1.4.1.818.1.1.18.9.11 | NonNegativeInteger32 | read-write | The installed battery capacity. This value is the 'factory'-value, not the value after calibration. |
| NUM upsConfigBatteryChargeCurrent_eighth | 1.3.6.1.4.1.818.1.1.18.9.12 | NonNegativeInteger32 | read-write | The maximum battery charge current, including external chargers. |
| INT upsConfigNoLoadShutdown_eighth | 1.3.6.1.4.1.818.1.1.18.9.13 | INTEGER | read-write | Dis- or enable 'no load' shutdown from the contact interface. |
| NUM upsConfigStartDelay_eighth | 1.3.6.1.4.1.818.1.1.18.9.14 | PositiveInteger32 | read-write | Minimum required autonomy time before the UPS may perform an autorestart. |
| upsGetSet_eighth | 1.3.6.1.4.1.818.1.1.18.10 | |||
| NUM upsEventGetNext_eighth | 1.3.6.1.4.1.818.1.1.18.10.1 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventSetStartingTimeStamp will be used as the start value of the table with the lowest index number. |
| NUM upsEventGetPrevious_eighth | 1.3.6.1.4.1.818.1.1.18.10.2 | PositiveInteger32 | read-write | The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventLastTime will be used as the last value of the table with the highest index number. Returns SNMP-NOSUCHNAME for UPSs that don't support this command. |
| NUM upsEventSetStartingTimeStamp_eighth | 1.3.6.1.4.1.818.1.1.18.10.3 | NonNegativeInteger32 | read-write | The timestamp which is used as starting point for downloading events from the UPS event buffer |
| NUM upsEventRetreiveCurrentTimeStamp_eighth | 1.3.6.1.4.1.818.1.1.18.10.4 | NonNegativeInteger32 | read-only | The current timestamp is retreived from the UPS |
| NUM upsEventTableSize_eighth | 1.3.6.1.4.1.818.1.1.18.10.5 | NonNegativeInteger32 | read-only | The number of entries in the event table. This object indicates the number of rows in the event table. |
| upsEventTable_eighth | 1.3.6.1.4.1.818.1.1.18.10.6 | not-accessible | A list of event table entries. The number of entries is always 10, and the value of upsEventTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..10)): PDU-SET upsSetStartingTimeStamp PDU-SET upsEventGetNext PDU-GET upsEventTableSize PDU-GET upsEventCode,upsEventStatus,upsEventTime 1 PDU-GET upsEventCode,upsEventStatus,upsEventTime 2 .. PDU-GET upsEventCode,upsEventStatus,upsEventTime The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsEventTableSize. | |
| upsEventEntry_eighth | 1.3.6.1.4.1.818.1.1.18.10.6.1 | not-accessible | An entry containing information applicable to a particular event. | |
| NUM upsEventLineIndex_eighth | 1.3.6.1.4.1.818.1.1.18.10.6.1.1 | PositiveInteger32 | not-accessible | The event line identifier. |
| NUM upsEventCode_eighth | 1.3.6.1.4.1.818.1.1.18.10.6.1.2 | NonNegativeInteger32 | read-only | The event code in numerical format. |
| NUM upsEventStatus_eighth | 1.3.6.1.4.1.818.1.1.18.10.6.1.3 | NonNegativeInteger32 | read-only | The status of the UPS at the moment that the event was generated. The format is specified at the 'upsStatus' command. If the UPS is not able to deliver status information, then SNMP-NOSUCHNAME is returned. |
| NUM upsEventTime_eighth | 1.3.6.1.4.1.818.1.1.18.10.6.1.4 | NonNegativeInteger32 | read-only | The timestamp of the moment the event was generated. |
| NUM upsParametersRead_eighth | 1.3.6.1.4.1.818.1.1.18.10.7 | PositiveInteger32 | read-write | The number of parameters to retreive from the UPS. When this object is set the ParameterTable will be filled with the requested number of entries. The value upsParametersStartAddress will be used as the start value of the table with the lowest index number. |
| NUM upsParametersWrite_eighth | 1.3.6.1.4.1.818.1.1.18.10.8 | PositiveInteger32 | read-write | The number of parameters to write to the UPS. When this object is set the ParameterTable will be send to the ups. The value upsParametersStartAddress will be used for the first value of the table with the lowest index number. |
| NUM upsParametersStartAddress_eighth | 1.3.6.1.4.1.818.1.1.18.10.9 | NonNegativeInteger32 | read-write | The address which is used as starting point for downloading parameters from the UPS |
| NUM upsParameterTableSize_eighth | 1.3.6.1.4.1.818.1.1.18.10.10 | NonNegativeInteger32 | read-only | The number of entries in the parameter table. This object indicates the number of rows in the parameter table. |
| upsParameterTable_eighth | 1.3.6.1.4.1.818.1.1.18.10.11 | not-accessible | A list of parameter entries. The number of entries is always 16, and the value of upsParameterTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..16)): Read sequence: PDU-SET upsSetStartingAddress PDU-SET upsParametersRead PDU-GET upsParameterTableSize PDU-GET upsParameterValue 1 PDU-GET upsParameterValue 2 .. PDU-GET upsParameterValue The table is read up to requested number of events and the management software afterwards decides which entries are valid, as indicated by the upsParameterTableSize. Write sequence: PDU-SET upsSetStartingAddress PDU-SET upsParameterValue 1 PDU-SET upsParameterValue 2 .. PDU-SET upsParameterValue PDU-SET upsParametersWrite | |
| upsParameterEntry_eighth | 1.3.6.1.4.1.818.1.1.18.10.11.1 | not-accessible | An entry containing information applicable to a particular parameter. | |
| NUM upsParameterLineIndex_eighth | 1.3.6.1.4.1.818.1.1.18.10.11.1.1 | PositiveInteger32 | not-accessible | The parameter line identifier. |
| I32 upsParameterValue_eighth | 1.3.6.1.4.1.818.1.1.18.10.11.1.2 | Integer32 | read-write | The parameter value in numerical format. |
| NUM upsStatus_eighth | 1.3.6.1.4.1.818.1.1.18.10.12 | NonNegativeInteger32 | read-only | The global UPS status is returned. Every bit reflects a specific status condition. Unused bits returns as 0. The status value can also be found on other commands. The value SNMP-NOSUCHNAME means 'invalid status' or 'status value non available'. Status 1 0001h upsStatusEcomodeIsOn 2 0002h upsStatusBatteryIsCharging 4 0004h upsStatusBatteryIsDischarging 8 0008h upsStatusAlarmIsActive 16 0010h upsStatusRectifierIsOn 32 0020h upsStatusLowBattery 64 0040h upsStatusOnBypass 128 0080h upsStatusMainsBypassOK 256 0100h upsStatusMainsRectifierOK 512 0200h upsStatusDetourIsOn 1024 0400h upsStatusAcousticAlarmIsOn 2048 0800h - (not used.) 4096 1000h upsStatusInverterIsOn 8192 2000h upsStatusNotInParallel (Q1 open) 16384 4000h upsStatusResetLoadOff 32768 8000h upsStatusLoadOff |
| NUM upsMainsStatisticsMBfail_eighth | 1.3.6.1.4.1.818.1.1.18.10.13 | NonNegativeInteger32 | read-only | Count of main bypass failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsMRfail_eighth | 1.3.6.1.4.1.818.1.1.18.10.14 | NonNegativeInteger32 | read-only | Count of mains rectifier failures (>200 ms), since UPS installation. |
| NUM upsMainsStatisticsB2_eighth | 1.3.6.1.4.1.818.1.1.18.10.15 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (0..2 ms), during the last 7 days. |
| NUM upsMainsStatisticsB5_eighth | 1.3.6.1.4.1.818.1.1.18.10.16 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (2..5 ms), during the last 7 days. |
| NUM upsMainsStatisticsB10_eighth | 1.3.6.1.4.1.818.1.1.18.10.17 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (5..10 ms), during the last 7 days. |
| NUM upsMainsStatisticsB200_eighth | 1.3.6.1.4.1.818.1.1.18.10.18 | NonNegativeInteger32 | read-only | Count of transients on the mains bypass (10..200 ms), during the last 7 days. |
| NUM upsMainsStatisticsBypRel_eighth | 1.3.6.1.4.1.818.1.1.18.10.19 | NonNegativeInteger32 | read-only | Bypass reliability degree [0..100%;255]. The value NOSUCHNAME means 'not available'. |
| NUM upsTime_eighth | 1.3.6.1.4.1.818.1.1.18.10.20 | NonNegativeInteger32 | read-write | The current timestamp (or real-time) of the UPS. For the format, see 'Timestamp' specifications. The write-command has to comply with the correct timestamp format expected by the UPS (counter value or real-time-clock value). Missing to doing so will result in a SNMP-eighthERROR, meaning 'command not supported'. It is possible to know which is the timestamp format supported by the UPS, by issuing a read-command or by reading events, which includes timestamps. |
| STR upsRequestPermission_eighth | 1.3.6.1.4.1.818.1.1.18.10.21 | DisplayString | write-only | An encrypted code is send to enable use of restricted write objects during a limited period of time. |
| I32 upsEventGetCode_eighth | 1.3.6.1.4.1.818.1.1.18.10.22 | Integer32 | write-only | The code which is used as starting point to downloading the events from the UPS event buffer. |
| TES upsEventSpinLock_eighth | 1.3.6.1.4.1.818.1.1.18.10.23 | TestAndIncr | read-write | A spin lock on the event subsystem. |
| TES upsParameterSpinLock_eighth | 1.3.6.1.4.1.818.1.1.18.10.24 | TestAndIncr | read-write | A spin lock on the parameters subsystem. |
| geUPSTraps_eighth | 1.3.6.1.4.1.818.1.1.18.11 | |||
| NTF upsAlarmBatteryBadTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.1 | One or more batteries have been determined to require replacement. | ||
| NTF upsAlarmOnBatteryTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.2 | An On Battery condition is restored. | ||
| NTF upsAlarmLowBatteryTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.3 | The remaining battery run-time is less than or equal to upsConfigLowBattTime. | ||
| NTF upsAlarmDepletedBatteryTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.4 | The UPS will be unable to sustain the present load when and if the utility power is lost) | ||
| NTF upsAlarmTempBadTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.5 | A temperature is out of tolerance. | ||
| NTF upsAlarmInputBadTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.6 | An input condition is out of tolerance. | ||
| NTF upsAlarmOutputBadTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.7 | An output condition (other than OutputOverload) is out of tolerance. | ||
| NTF upsAlarmOutputOverloadTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.8 | The output load exceeds the UPS output capacity. | ||
| NTF upsAlarmOnBypassTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.9 | The Bypass is presently engaged on the UPS. | ||
| NTF upsAlarmBypassBadTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.10 | The Bypass is out of tolerance. | ||
| NTF upsAlarmOutputOffAsRequestedTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.11 | The UPS has shutdown as requested, i.e., the output is off. | ||
| NTF upsAlarmUpsOffAsRequestedTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.12 | The entire UPS has shutdown as commanded. | ||
| NTF upsAlarmChargerFailedTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.13 | An uncorrected problem has been detected within the UPS charger subsystem. | ||
| NTF upsAlarmUpsOutputOffTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.14 | The output of the UPS is in the off state. | ||
| NTF upsAlarmUpsSystemOffTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.15 | The UPS system is in the off state. | ||
| NTF upsAlarmFanFailureTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.16 | The failure of one or more fans in the UPS has been detected. | ||
| NTF upsAlarmFuseFailureTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.17 | The failure of one or more fuses has been detected. | ||
| NTF upsAlarmGeneralFaultTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.18 | A general fault in the UPS has been detected. | ||
| NTF upsAlarmDiagnosticTestFailedTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.19 | The result of the last diagnostic test indicates a failure. | ||
| NTF upsAlarmCommunicationsLostTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.20 | A problem has been encountered in the communication between the agent and the UPS. | ||
| NTF upsAlarmAwaitingPowerTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.21 | The UPS output is off and the UPS is awaiting the return of the input power (*). | ||
| NTF upsAlarmShutdownPendingTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.22 | A upsShutdownAfterDelay countdown is underway. | ||
| NTF upsAlarmShutdownImminentTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.23 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | ||
| NTF upsAlarmTestInProgressTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.24 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | ||
| NTF upsAlarmReceptacleOffTrap_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.25 | A receptacle has been switched off. | ||
| NTF upsAlarmBatteryBadRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.33 | A Battery bad condition is restored. | ||
| NTF upsAlarmOnBatteryRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.34 | The UPS is drawing power from mains again. | ||
| NTF upsAlarmLowBatteryRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.35 | A Low Battery condition is restored. | ||
| NTF upsAlarmDepletedBatteryRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.36 | A Depleted Battery condition is restored. | ||
| NTF upsAlarmTempBadRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.37 | A bad temperature condition is restored. | ||
| NTF upsAlarmInputBadRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.38 | An input bad condition is restored. | ||
| NTF upsAlarmOutputBadRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.39 | An output bad condition is restored. | ||
| NTF upsAlarmOutputOverloadRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.40 | An output overload condition is restored. | ||
| NTF upsAlarmOnBypassRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.41 | An On Bypass condition is restored. | ||
| NTF upsAlarmBypassBadRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.42 | A Bypass bad condition is restored. | ||
| NTF upsAlarmOutputOffAsRequestedRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.43 | A request shutdown has been restored. | ||
| NTF upsAlarmUpsOffAsRequestedRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.44 | A entire UPS command has been restored. | ||
| NTF upsAlarmChargerFailedRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.45 | A Charger Failer condition is restored. | ||
| NTF upsAlarmUpsOutputOn_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.46 | The output of the UPS switched in the on state. | ||
| NTF upsAlarmUpsSystemOn_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.47 | The UPS system is switched in the on state. | ||
| NTF upsAlarmFanFailureRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.48 | A Fan failure condition is restored. | ||
| NTF upsAlarmFuseFailureRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.49 | A Fuse failure condition is restored. | ||
| NTF upsAlarmGeneralFaultRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.50 | A general fault is restored. | ||
| NTF upsAlarmDiagnosticTestFailedRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.51 | A last diagnostic test indicates a failure is restored. | ||
| NTF upsAlarmCommunicationsLostRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.52 | A problem in the communication between the agent and the UPS is restored. | ||
| NTF upsAlarmAwaitingPowerRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.53 | A awaiting power condition is restored (*). | ||
| NTF upsAlarmShutdownPendingRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.54 | A upsShutdownAfterDelay countdown is restored. | ||
| NTF upsAlarmShutdownImminentRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.55 | A shutdown imminent condition is restored. | ||
| NTF upsAlarmTestInProgressRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.56 | The test is in progress is terminated. | ||
| NTF upsAlarmReceptacleOn_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.57 | A receptacle has been switched on. | ||
| NTF upsAlarmValueLow_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.129 | A measurement value reached a value below its low-level threshold. | ||
| NTF upsAlarmValueHigh_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.130 | A measurement value reached a value higher than its high-level threshold. | ||
| NTF upsAlarmValueLowRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.133 | A ValueLow alarm condition is restored. | ||
| NTF upsAlarmValueHighRestored_eighth | 1.3.6.1.4.1.818.1.1.18.11.0.134 | A ValueHigh alarm condition is restored. | ||
| geEnvironmental | 1.3.6.1.4.1.818.1.2 | |||
| ioInterface_First | 1.3.6.1.4.1.818.1.2.1 | |||
| ioInterfaceInputLine_First | 1.3.6.1.4.1.818.1.2.1.1 | |||
| NUM ioInterfaceNumInputs_First | 1.3.6.1.4.1.818.1.2.1.1.1 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This entry indicates the number of rows in the input table. |
| ioInterfaceInputTable_First | 1.3.6.1.4.1.818.1.2.1.1.2 | not-accessible | A list of input line table entries. The number of entries is given by the value of ioInterfaceNumInputs. | |
| ioInterfaceInputEntry_First | 1.3.6.1.4.1.818.1.2.1.1.2.1 | not-accessible | An entry containing information applicable to a particular input line. | |
| NUM ioInterfaceInputLineIndex_First | 1.3.6.1.4.1.818.1.2.1.1.2.1.1 | PositiveInteger32 | not-accessible | The input line identifier. |
| STR ioInterfaceInputDescription_First | 1.3.6.1.4.1.818.1.2.1.1.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this input line. |
| INT ioInterfaceInputStatus_First | 1.3.6.1.4.1.818.1.2.1.1.2.1.3 | INTEGER | read-only | The status of the input lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| INT ioInterfaceEdgeMode_First | 1.3.6.1.4.1.818.1.2.1.1.2.1.4 | INTEGER | read-write | Edge mode for input lines. This object specifies if the corresponding input line should be recognised immediately as active (edge mode on), or only when the state remains stable for at least the time specified by ioInterfaceAlarmDelay (edge mode off). EdgeMode is only meaningful when the object ioInterfaceAlarmMask is active. |
| INT ioInterfaceAlarmMask_First | 1.3.6.1.4.1.818.1.2.1.1.2.1.5 | INTEGER | read-write | Alarm functionality for the input line can be set active or inactive. |
| NUM ioInterfaceAlarmDelay_First | 1.3.6.1.4.1.818.1.2.1.1.3 | NonNegativeInteger32 | read-write | Time delay during which an active input line has to be stable, prior to issue an alarm. Effective only when EdgeMode=off for the corresponding line. |
| ioInterfaceOutputLine_First | 1.3.6.1.4.1.818.1.2.1.2 | |||
| NUM ioInterfaceNumOutput_First | 1.3.6.1.4.1.818.1.2.1.2.1 | NonNegativeInteger32 | read-only | The number of output lines utilized by this device. This entry indicates the number of rows in the output line table. |
| ioInterfaceOutputTable_First | 1.3.6.1.4.1.818.1.2.1.2.2 | not-accessible | A list of output line table entries. The number of entries is given by the value of ioInterfaceNumOutputs. | |
| ioInterfaceOutputEntry_First | 1.3.6.1.4.1.818.1.2.1.2.2.1 | not-accessible | An entry containing information applicable to a particular output line. | |
| NUM ioInterfaceOutputLineIndex_First | 1.3.6.1.4.1.818.1.2.1.2.2.1.1 | PositiveInteger32 | not-accessible | The output line identifier. |
| STR ioInterfaceOutputDescription_First | 1.3.6.1.4.1.818.1.2.1.2.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this output line. |
| INT ioInterfaceOutputStatus_First | 1.3.6.1.4.1.818.1.2.1.2.2.1.3 | INTEGER | read-write | The status of the output lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| ioInterfaceAnalogueLine_First | 1.3.6.1.4.1.818.1.2.1.3 | |||
| NUM ioInterfaceNumAnalogue_First | 1.3.6.1.4.1.818.1.2.1.3.1 | NonNegativeInteger32 | read-only | The number of analogue lines utilized by this device. This entry indicates the number of rows in the analogue line table. |
| ioInterfaceAnalogueTable_First | 1.3.6.1.4.1.818.1.2.1.3.2 | not-accessible | A list of analogue line table entries. The number of entries is given by the value of ioInterfaceNumAnalogue. | |
| ioInterfaceAnalogueEntry_First | 1.3.6.1.4.1.818.1.2.1.3.2.1 | not-accessible | An entry containing information applicable to a particular analogue line. | |
| NUM ioInterfaceAnalogueLineIndex_First | 1.3.6.1.4.1.818.1.2.1.3.2.1.1 | PositiveInteger32 | not-accessible | The analogue line identifier. |
| STR ioInterfaceAnalogueDescription_First | 1.3.6.1.4.1.818.1.2.1.3.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this analogue line. |
| I32 ioInterfaceAnalogueStatus_First | 1.3.6.1.4.1.818.1.2.1.3.2.1.3 | Integer32 | read-only | Read analogue value 1, when the board support such functionality |
| I32 ioInterfaceAnalogueLowThreshold_First | 1.3.6.1.4.1.818.1.2.1.3.2.1.4 | Integer32 | read-write | Low limit for the analogical value. When the analogical measurement comes under this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueHighThreshold_First | 1.3.6.1.4.1.818.1.2.1.3.2.1.5 | Integer32 | read-write | High limit for the analogical value. When the analogical measurement comes higher than this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueResetLowThreshold_First | 1.3.6.1.4.1.818.1.2.1.3.2.1.6 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the low alarm condition (hysteresis) |
| I32 ioInterfaceAnalogueResetHighThreshold_First | 1.3.6.1.4.1.818.1.2.1.3.2.1.7 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the high alarm condition (hysteresis) |
| ioInterfaceTraps_First | 1.3.6.1.4.1.818.1.2.1.4 | |||
| NTF ioAlarmGenericChange_First | 1.3.6.1.4.1.818.1.2.1.4.0.1 | An generic change of a digital input/digital output/analog input has become active. | ||
| ioInterface_Second | 1.3.6.1.4.1.818.1.2.2 | |||
| ioInterfaceInputLine_Second | 1.3.6.1.4.1.818.1.2.2.1 | |||
| NUM ioInterfaceNumInputs_Second | 1.3.6.1.4.1.818.1.2.2.1.1 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This entry indicates the number of rows in the input table. |
| ioInterfaceInputTable_Second | 1.3.6.1.4.1.818.1.2.2.1.2 | not-accessible | A list of input line table entries. The number of entries is given by the value of ioInterfaceNumInputs. | |
| ioInterfaceInputEntry_Second | 1.3.6.1.4.1.818.1.2.2.1.2.1 | not-accessible | An entry containing information applicable to a particular input line. | |
| NUM ioInterfaceInputLineIndex_Second | 1.3.6.1.4.1.818.1.2.2.1.2.1.1 | PositiveInteger32 | not-accessible | The input line identifier. |
| STR ioInterfaceInputDescription_Second | 1.3.6.1.4.1.818.1.2.2.1.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this input line. |
| INT ioInterfaceInputStatus_Second | 1.3.6.1.4.1.818.1.2.2.1.2.1.3 | INTEGER | read-only | The status of the input lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| INT ioInterfaceEdgeMode_Second | 1.3.6.1.4.1.818.1.2.2.1.2.1.4 | INTEGER | read-write | Edge mode for input lines. This object specifies if the corresponding input line should be recognised immediately as active (edge mode on), or only when the state remains stable for at least the time specified by ioInterfaceAlarmDelay (edge mode off). EdgeMode is only meaningful when the object ioInterfaceAlarmMask is active. |
| INT ioInterfaceAlarmMask_Second | 1.3.6.1.4.1.818.1.2.2.1.2.1.5 | INTEGER | read-write | Alarm functionality for the input line can be set active or inactive. |
| NUM ioInterfaceAlarmDelay_Second | 1.3.6.1.4.1.818.1.2.2.1.2.1.6 | NonNegativeInteger32 | read-write | Time delay during which an active input line has to be stable, prior to issue an alarm. Effective only when EdgeMode=off for the corresponding line. |
| ioInterfaceOutputLine_Second | 1.3.6.1.4.1.818.1.2.2.2 | |||
| NUM ioInterfaceNumOutput_Second | 1.3.6.1.4.1.818.1.2.2.2.1 | NonNegativeInteger32 | read-only | The number of output lines utilized by this device. This entry indicates the number of rows in the output line table. |
| ioInterfaceOutputTable_Second | 1.3.6.1.4.1.818.1.2.2.2.2 | not-accessible | A list of output line table entries. The number of entries is given by the value of ioInterfaceNumOutputs. | |
| ioInterfaceOutputEntry_Second | 1.3.6.1.4.1.818.1.2.2.2.2.1 | not-accessible | An entry containing information applicable to a particular output line. | |
| NUM ioInterfaceOutputLineIndex_Second | 1.3.6.1.4.1.818.1.2.2.2.2.1.1 | PositiveInteger32 | not-accessible | The output line identifier. |
| STR ioInterfaceOutputDescription_Second | 1.3.6.1.4.1.818.1.2.2.2.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this output line. |
| INT ioInterfaceOutputStatus_Second | 1.3.6.1.4.1.818.1.2.2.2.2.1.3 | INTEGER | read-write | The status of the output lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| ioInterfaceAnalogueLine_Second | 1.3.6.1.4.1.818.1.2.2.3 | |||
| NUM ioInterfaceNumAnalogue_Second | 1.3.6.1.4.1.818.1.2.2.3.1 | NonNegativeInteger32 | read-only | The number of analogue lines utilized by this device. This entry indicates the number of rows in the analogue line table. |
| ioInterfaceAnalogueTable_Second | 1.3.6.1.4.1.818.1.2.2.3.2 | not-accessible | A list of analogue line table entries. The number of entries is given by the value of ioInterfaceNumAnalogue. | |
| ioInterfaceAnalogueEntry_Second | 1.3.6.1.4.1.818.1.2.2.3.2.1 | not-accessible | An entry containing information applicable to a particular analogue line. | |
| NUM ioInterfaceAnalogueLineIndex_Second | 1.3.6.1.4.1.818.1.2.2.3.2.1.1 | PositiveInteger32 | not-accessible | The analogue line identifier. |
| STR ioInterfaceAnalogueDescription_Second | 1.3.6.1.4.1.818.1.2.2.3.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this analogue line. |
| I32 ioInterfaceAnalogueStatus_Second | 1.3.6.1.4.1.818.1.2.2.3.2.1.3 | Integer32 | read-only | Read analogue value 1, when the board support such functionality |
| I32 ioInterfaceAnalogueLowThreshold_Second | 1.3.6.1.4.1.818.1.2.2.3.2.1.4 | Integer32 | read-write | Low limit for the analogical value. When the analogical measurement comes under this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueHighThreshold_Second | 1.3.6.1.4.1.818.1.2.2.3.2.1.5 | Integer32 | read-write | High limit for the analogical value. When the analogical measurement comes higher than this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueResetLowThreshold_Second | 1.3.6.1.4.1.818.1.2.2.3.2.1.6 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the low alarm condition (hysteresis) |
| I32 ioInterfaceAnalogueResetHighThreshold_Second | 1.3.6.1.4.1.818.1.2.2.3.2.1.7 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the high alarm condition (hysteresis) |
| ioInterfaceTraps_Second | 1.3.6.1.4.1.818.1.2.2.4 | |||
| NTF ioAlarmGenericChange_Second | 1.3.6.1.4.1.818.1.2.2.4.0.1 | An generic change of a digital input/digital output/analog input has become active. | ||
| ioInterface_Third | 1.3.6.1.4.1.818.1.2.3 | |||
| ioInterfaceInputLine_Third | 1.3.6.1.4.1.818.1.2.3.1 | |||
| NUM ioInterfaceNumInputs_Third | 1.3.6.1.4.1.818.1.2.3.1.1 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This entry indicates the number of rows in the input table. |
| ioInterfaceInputTable_Third | 1.3.6.1.4.1.818.1.2.3.1.2 | not-accessible | A list of input line table entries. The number of entries is given by the value of ioInterfaceNumInputs. | |
| ioInterfaceInputEntry_Third | 1.3.6.1.4.1.818.1.2.3.1.2.1 | not-accessible | An entry containing information applicable to a particular input line. | |
| NUM ioInterfaceInputLineIndex_Third | 1.3.6.1.4.1.818.1.2.3.1.2.1.1 | PositiveInteger32 | not-accessible | The input line identifier. |
| STR ioInterfaceInputDescription_Third | 1.3.6.1.4.1.818.1.2.3.1.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this input line. |
| INT ioInterfaceInputStatus_Third | 1.3.6.1.4.1.818.1.2.3.1.2.1.3 | INTEGER | read-only | The status of the input lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| INT ioInterfaceEdgeMode_Third | 1.3.6.1.4.1.818.1.2.3.1.2.1.4 | INTEGER | read-write | Edge mode for input lines. This object specifies if the corresponding input line should be recognised immediately as active (edge mode on), or only when the state remains stable for at least the time specified by ioInterfaceAlarmDelay (edge mode off). EdgeMode is only meaningful when the object ioInterfaceAlarmMask is active. |
| INT ioInterfaceAlarmMask_Third | 1.3.6.1.4.1.818.1.2.3.1.2.1.5 | INTEGER | read-write | Alarm functionality for the input line can be set active or inactive. |
| NUM ioInterfaceAlarmDelay_Third | 1.3.6.1.4.1.818.1.2.3.1.2.1.6 | NonNegativeInteger32 | read-write | Time delay during which an active input line has to be stable, prior to issue an alarm. Effective only when EdgeMode=off for the corresponding line. |
| ioInterfaceOutputLine_Third | 1.3.6.1.4.1.818.1.2.3.2 | |||
| NUM ioInterfaceNumOutput_Third | 1.3.6.1.4.1.818.1.2.3.2.1 | NonNegativeInteger32 | read-only | The number of output lines utilized by this device. This entry indicates the number of rows in the output line table. |
| ioInterfaceOutputTable_Third | 1.3.6.1.4.1.818.1.2.3.2.2 | not-accessible | A list of output line table entries. The number of entries is given by the value of ioInterfaceNumOutputs. | |
| ioInterfaceOutputEntry_Third | 1.3.6.1.4.1.818.1.2.3.2.2.1 | not-accessible | An entry containing information applicable to a particular output line. | |
| NUM ioInterfaceOutputLineIndex_Third | 1.3.6.1.4.1.818.1.2.3.2.2.1.1 | PositiveInteger32 | not-accessible | The output line identifier. |
| STR ioInterfaceOutputDescription_Third | 1.3.6.1.4.1.818.1.2.3.2.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this output line. |
| INT ioInterfaceOutputStatus_Third | 1.3.6.1.4.1.818.1.2.3.2.2.1.3 | INTEGER | read-write | The status of the output lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| ioInterfaceAnalogueLine_Third | 1.3.6.1.4.1.818.1.2.3.3 | |||
| NUM ioInterfaceNumAnalogue_Third | 1.3.6.1.4.1.818.1.2.3.3.1 | NonNegativeInteger32 | read-only | The number of analogue lines utilized by this device. This entry indicates the number of rows in the analogue line table. |
| ioInterfaceAnalogueTable_Third | 1.3.6.1.4.1.818.1.2.3.3.2 | not-accessible | A list of analogue line table entries. The number of entries is given by the value of ioInterfaceNumAnalogue. | |
| ioInterfaceAnalogueEntry_Third | 1.3.6.1.4.1.818.1.2.3.3.2.1 | not-accessible | An entry containing information applicable to a particular analogue line. | |
| NUM ioInterfaceAnalogueLineIndex_Third | 1.3.6.1.4.1.818.1.2.3.3.2.1.1 | PositiveInteger32 | not-accessible | The analogue line identifier. |
| STR ioInterfaceAnalogueDescription_Third | 1.3.6.1.4.1.818.1.2.3.3.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this analogue line. |
| I32 ioInterfaceAnalogueStatus_Third | 1.3.6.1.4.1.818.1.2.3.3.2.1.3 | Integer32 | read-only | Read analogue value 1, when the board support such functionality |
| I32 ioInterfaceAnalogueLowThreshold_Third | 1.3.6.1.4.1.818.1.2.3.3.2.1.4 | Integer32 | read-write | Low limit for the analogical value. When the analogical measurement comes under this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueHighThreshold_Third | 1.3.6.1.4.1.818.1.2.3.3.2.1.5 | Integer32 | read-write | High limit for the analogical value. When the analogical measurement comes higher than this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueResetLowThreshold_Third | 1.3.6.1.4.1.818.1.2.3.3.2.1.6 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the low alarm condition (hysteresis) |
| I32 ioInterfaceAnalogueResetHighThreshold_Third | 1.3.6.1.4.1.818.1.2.3.3.2.1.7 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the high alarm condition (hysteresis) |
| ioInterfaceTraps_Third | 1.3.6.1.4.1.818.1.2.3.4 | |||
| NTF ioAlarmGenericChange_Third | 1.3.6.1.4.1.818.1.2.3.4.0.1 | An generic change of a digital input/digital output/analog input has become active. | ||
| ioInterface_Fourth | 1.3.6.1.4.1.818.1.2.4 | |||
| ioInterfaceInputLine_Fourth | 1.3.6.1.4.1.818.1.2.4.1 | |||
| NUM ioInterfaceNumInputs_Fourth | 1.3.6.1.4.1.818.1.2.4.1.1 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This entry indicates the number of rows in the input table. |
| ioInterfaceInputTable_Fourth | 1.3.6.1.4.1.818.1.2.4.1.2 | not-accessible | A list of input line table entries. The number of entries is given by the value of ioInterfaceNumInputs. | |
| ioInterfaceInputEntry_Fourth | 1.3.6.1.4.1.818.1.2.4.1.2.1 | not-accessible | An entry containing information applicable to a particular input line. | |
| NUM ioInterfaceInputLineIndex_Fourth | 1.3.6.1.4.1.818.1.2.4.1.2.1.1 | PositiveInteger32 | not-accessible | The input line identifier. |
| STR ioInterfaceInputDescription_Fourth | 1.3.6.1.4.1.818.1.2.4.1.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this input line. |
| INT ioInterfaceInputStatus_Fourth | 1.3.6.1.4.1.818.1.2.4.1.2.1.3 | INTEGER | read-only | The status of the input lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| INT ioInterfaceEdgeMode_Fourth | 1.3.6.1.4.1.818.1.2.4.1.2.1.4 | INTEGER | read-write | Edge mode for input lines. This object specifies if the corresponding input line should be recognised immediately as active (edge mode on), or only when the state remains stable for at least the time specified by ioInterfaceAlarmDelay (edge mode off). EdgeMode is only meaningful when the object ioInterfaceAlarmMask is active. |
| INT ioInterfaceAlarmMask_Fourth | 1.3.6.1.4.1.818.1.2.4.1.2.1.5 | INTEGER | read-write | Alarm functionality for the input line can be set active or inactive. |
| NUM ioInterfaceAlarmDelay_Fourth | 1.3.6.1.4.1.818.1.2.4.1.2.1.6 | NonNegativeInteger32 | read-write | Time delay during which an active input line has to be stable, prior to issue an alarm. Effective only when EdgeMode=off for the corresponding line. |
| ioInterfaceOutputLine_Fourth | 1.3.6.1.4.1.818.1.2.4.2 | |||
| NUM ioInterfaceNumOutput_Fourth | 1.3.6.1.4.1.818.1.2.4.2.1 | NonNegativeInteger32 | read-only | The number of output lines utilized by this device. This entry indicates the number of rows in the output line table. |
| ioInterfaceOutputTable_Fourth | 1.3.6.1.4.1.818.1.2.4.2.2 | not-accessible | A list of output line table entries. The number of entries is given by the value of ioInterfaceNumOutputs. | |
| ioInterfaceOutputEntry_Fourth | 1.3.6.1.4.1.818.1.2.4.2.2.1 | not-accessible | An entry containing information applicable to a particular output line. | |
| NUM ioInterfaceOutputLineIndex_Fourth | 1.3.6.1.4.1.818.1.2.4.2.2.1.1 | PositiveInteger32 | not-accessible | The output line identifier. |
| STR ioInterfaceOutputDescription_Fourth | 1.3.6.1.4.1.818.1.2.4.2.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this output line. |
| INT ioInterfaceOutputStatus_Fourth | 1.3.6.1.4.1.818.1.2.4.2.2.1.3 | INTEGER | read-write | The status of the output lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| ioInterfaceAnalogueLine_Fourth | 1.3.6.1.4.1.818.1.2.4.3 | |||
| NUM ioInterfaceNumAnalogue_Fourth | 1.3.6.1.4.1.818.1.2.4.3.1 | NonNegativeInteger32 | read-only | The number of analogue lines utilized by this device. This entry indicates the number of rows in the analogue line table. |
| ioInterfaceAnalogueTable_Fourth | 1.3.6.1.4.1.818.1.2.4.3.2 | not-accessible | A list of analogue line table entries. The number of entries is given by the value of ioInterfaceNumAnalogue. | |
| ioInterfaceAnalogueEntry_Fourth | 1.3.6.1.4.1.818.1.2.4.3.2.1 | not-accessible | An entry containing information applicable to a particular analogue line. | |
| NUM ioInterfaceAnalogueLineIndex_Fourth | 1.3.6.1.4.1.818.1.2.4.3.2.1.1 | PositiveInteger32 | not-accessible | The analogue line identifier. |
| STR ioInterfaceAnalogueDescription_Fourth | 1.3.6.1.4.1.818.1.2.4.3.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this analogue line. |
| I32 ioInterfaceAnalogueStatus_Fourth | 1.3.6.1.4.1.818.1.2.4.3.2.1.3 | Integer32 | read-only | Read analogue value 1, when the board support such functionality |
| I32 ioInterfaceAnalogueLowThreshold_Fourth | 1.3.6.1.4.1.818.1.2.4.3.2.1.4 | Integer32 | read-write | Low limit for the analogical value. When the analogical measurement comes under this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueHighThreshold_Fourth | 1.3.6.1.4.1.818.1.2.4.3.2.1.5 | Integer32 | read-write | High limit for the analogical value. When the analogical measurement comes higher than this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueResetLowThreshold_Fourth | 1.3.6.1.4.1.818.1.2.4.3.2.1.6 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the low alarm condition (hysteresis) |
| I32 ioInterfaceAnalogueResetHighThreshold_Fourth | 1.3.6.1.4.1.818.1.2.4.3.2.1.7 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the high alarm condition (hysteresis) |
| ioInterfaceTraps_Fourth | 1.3.6.1.4.1.818.1.2.4.4 | |||
| NTF ioAlarmGenericChange_Fourth | 1.3.6.1.4.1.818.1.2.4.4.0.1 | An generic change of a digital input/digital output/analog input has become active. | ||
| ioInterface_Fifth | 1.3.6.1.4.1.818.1.2.5 | |||
| ioInterfaceInputLine_Fifth | 1.3.6.1.4.1.818.1.2.5.1 | |||
| NUM ioInterfaceNumInputs_Fifth | 1.3.6.1.4.1.818.1.2.5.1.1 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This entry indicates the number of rows in the input table. |
| ioInterfaceInputTable_Fifth | 1.3.6.1.4.1.818.1.2.5.1.2 | not-accessible | A list of input line table entries. The number of entries is given by the value of ioInterfaceNumInputs. | |
| ioInterfaceInputEntry_Fifth | 1.3.6.1.4.1.818.1.2.5.1.2.1 | not-accessible | An entry containing information applicable to a particular input line. | |
| NUM ioInterfaceInputLineIndex_Fifth | 1.3.6.1.4.1.818.1.2.5.1.2.1.1 | PositiveInteger32 | not-accessible | The input line identifier. |
| STR ioInterfaceInputDescription_Fifth | 1.3.6.1.4.1.818.1.2.5.1.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this input line. |
| INT ioInterfaceInputStatus_Fifth | 1.3.6.1.4.1.818.1.2.5.1.2.1.3 | INTEGER | read-only | The status of the input lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| INT ioInterfaceEdgeMode_Fifth | 1.3.6.1.4.1.818.1.2.5.1.2.1.4 | INTEGER | read-write | Edge mode for input lines. This object specifies if the corresponding input line should be recognised immediately as active (edge mode on), or only when the state remains stable for at least the time specified by ioInterfaceAlarmDelay (edge mode off). EdgeMode is only meaningful when the object ioInterfaceAlarmMask is active. |
| INT ioInterfaceAlarmMask_Fifth | 1.3.6.1.4.1.818.1.2.5.1.2.1.5 | INTEGER | read-write | Alarm functionality for the input line can be set active or inactive. |
| NUM ioInterfaceAlarmDelay_Fifth | 1.3.6.1.4.1.818.1.2.5.1.2.1.6 | NonNegativeInteger32 | read-write | Time delay during which an active input line has to be stable, prior to issue an alarm. Effective only when EdgeMode=off for the corresponding line. |
| ioInterfaceOutputLine_Fifth | 1.3.6.1.4.1.818.1.2.5.2 | |||
| NUM ioInterfaceNumOutput_Fifth | 1.3.6.1.4.1.818.1.2.5.2.1 | NonNegativeInteger32 | read-only | The number of output lines utilized by this device. This entry indicates the number of rows in the output line table. |
| ioInterfaceOutputTable_Fifth | 1.3.6.1.4.1.818.1.2.5.2.2 | not-accessible | A list of output line table entries. The number of entries is given by the value of ioInterfaceNumOutputs. | |
| ioInterfaceOutputEntry_Fifth | 1.3.6.1.4.1.818.1.2.5.2.2.1 | not-accessible | An entry containing information applicable to a particular output line. | |
| NUM ioInterfaceOutputLineIndex_Fifth | 1.3.6.1.4.1.818.1.2.5.2.2.1.1 | PositiveInteger32 | not-accessible | The output line identifier. |
| STR ioInterfaceOutputDescription_Fifth | 1.3.6.1.4.1.818.1.2.5.2.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this output line. |
| INT ioInterfaceOutputStatus_Fifth | 1.3.6.1.4.1.818.1.2.5.2.2.1.3 | INTEGER | read-write | The status of the output lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| ioInterfaceAnalogueLine_Fifth | 1.3.6.1.4.1.818.1.2.5.3 | |||
| NUM ioInterfaceNumAnalogue_Fifth | 1.3.6.1.4.1.818.1.2.5.3.1 | NonNegativeInteger32 | read-only | The number of analogue lines utilized by this device. This entry indicates the number of rows in the analogue line table. |
| ioInterfaceAnalogueTable_Fifth | 1.3.6.1.4.1.818.1.2.5.3.2 | not-accessible | A list of analogue line table entries. The number of entries is given by the value of ioInterfaceNumAnalogue. | |
| ioInterfaceAnalogueEntry_Fifth | 1.3.6.1.4.1.818.1.2.5.3.2.1 | not-accessible | An entry containing information applicable to a particular analogue line. | |
| NUM ioInterfaceAnalogueLineIndex_Fifth | 1.3.6.1.4.1.818.1.2.5.3.2.1.1 | PositiveInteger32 | not-accessible | The analogue line identifier. |
| STR ioInterfaceAnalogueDescription_Fifth | 1.3.6.1.4.1.818.1.2.5.3.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this analogue line. |
| I32 ioInterfaceAnalogueStatus_Fifth | 1.3.6.1.4.1.818.1.2.5.3.2.1.3 | Integer32 | read-only | Read analogue value 1, when the board support such functionality |
| I32 ioInterfaceAnalogueLowThreshold_Fifth | 1.3.6.1.4.1.818.1.2.5.3.2.1.4 | Integer32 | read-write | Low limit for the analogical value. When the analogical measurement comes under this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueHighThreshold_Fifth | 1.3.6.1.4.1.818.1.2.5.3.2.1.5 | Integer32 | read-write | High limit for the analogical value. When the analogical measurement comes higher than this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueResetLowThreshold_Fifth | 1.3.6.1.4.1.818.1.2.5.3.2.1.6 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the low alarm condition (hysteresis) |
| I32 ioInterfaceAnalogueResetHighThreshold_Fifth | 1.3.6.1.4.1.818.1.2.5.3.2.1.7 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the high alarm condition (hysteresis) |
| ioInterfaceTraps_Fifth | 1.3.6.1.4.1.818.1.2.5.4 | |||
| NTF ioAlarmGenericChange_Fifth | 1.3.6.1.4.1.818.1.2.5.4.0.1 | An generic change of a digital input/digital output/analog input has become active. | ||
| ioInterface_Sixth | 1.3.6.1.4.1.818.1.2.6 | |||
| ioInterfaceInputLine_Sixth | 1.3.6.1.4.1.818.1.2.6.1 | |||
| NUM ioInterfaceNumInputs_Sixth | 1.3.6.1.4.1.818.1.2.6.1.1 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This entry indicates the number of rows in the input table. |
| ioInterfaceInputTable_Sixth | 1.3.6.1.4.1.818.1.2.6.1.2 | not-accessible | A list of input line table entries. The number of entries is given by the value of ioInterfaceNumInputs. | |
| ioInterfaceInputEntry_Sixth | 1.3.6.1.4.1.818.1.2.6.1.2.1 | not-accessible | An entry containing information applicable to a particular input line. | |
| NUM ioInterfaceInputLineIndex_Sixth | 1.3.6.1.4.1.818.1.2.6.1.2.1.1 | PositiveInteger32 | not-accessible | The input line identifier. |
| STR ioInterfaceInputDescription_Sixth | 1.3.6.1.4.1.818.1.2.6.1.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this input line. |
| INT ioInterfaceInputStatus_Sixth | 1.3.6.1.4.1.818.1.2.6.1.2.1.3 | INTEGER | read-only | The status of the input lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| INT ioInterfaceEdgeMode_Sixth | 1.3.6.1.4.1.818.1.2.6.1.2.1.4 | INTEGER | read-write | Edge mode for input lines. This object specifies if the corresponding input line should be recognised immediately as active (edge mode on), or only when the state remains stable for at least the time specified by ioInterfaceAlarmDelay (edge mode off). EdgeMode is only meaningful when the object ioInterfaceAlarmMask is active. |
| INT ioInterfaceAlarmMask_Sixth | 1.3.6.1.4.1.818.1.2.6.1.2.1.5 | INTEGER | read-write | Alarm functionality for the input line can be set active or inactive. |
| NUM ioInterfaceAlarmDelay_Sixth | 1.3.6.1.4.1.818.1.2.6.1.2.1.6 | NonNegativeInteger32 | read-write | Time delay during which an active input line has to be stable, prior to issue an alarm. Effective only when EdgeMode=off for the corresponding line. |
| ioInterfaceOutputLine_Sixth | 1.3.6.1.4.1.818.1.2.6.2 | |||
| NUM ioInterfaceNumOutput_Sixth | 1.3.6.1.4.1.818.1.2.6.2.1 | NonNegativeInteger32 | read-only | The number of output lines utilized by this device. This entry indicates the number of rows in the output line table. |
| ioInterfaceOutputTable_Sixth | 1.3.6.1.4.1.818.1.2.6.2.2 | not-accessible | A list of output line table entries. The number of entries is given by the value of ioInterfaceNumOutputs. | |
| ioInterfaceOutputEntry_Sixth | 1.3.6.1.4.1.818.1.2.6.2.2.1 | not-accessible | An entry containing information applicable to a particular output line. | |
| NUM ioInterfaceOutputLineIndex_Sixth | 1.3.6.1.4.1.818.1.2.6.2.2.1.1 | PositiveInteger32 | not-accessible | The output line identifier. |
| STR ioInterfaceOutputDescription_Sixth | 1.3.6.1.4.1.818.1.2.6.2.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this output line. |
| INT ioInterfaceOutputStatus_Sixth | 1.3.6.1.4.1.818.1.2.6.2.2.1.3 | INTEGER | read-write | The status of the output lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| ioInterfaceAnalogueLine_Sixth | 1.3.6.1.4.1.818.1.2.6.3 | |||
| NUM ioInterfaceNumAnalogue_Sixth | 1.3.6.1.4.1.818.1.2.6.3.1 | NonNegativeInteger32 | read-only | The number of analogue lines utilized by this device. This entry indicates the number of rows in the analogue line table. |
| ioInterfaceAnalogueTable_Sixth | 1.3.6.1.4.1.818.1.2.6.3.2 | not-accessible | A list of analogue line table entries. The number of entries is given by the value of ioInterfaceNumAnalogue. | |
| ioInterfaceAnalogueEntry_Sixth | 1.3.6.1.4.1.818.1.2.6.3.2.1 | not-accessible | An entry containing information applicable to a particular analogue line. | |
| NUM ioInterfaceAnalogueLineIndex_Sixth | 1.3.6.1.4.1.818.1.2.6.3.2.1.1 | PositiveInteger32 | not-accessible | The analogue line identifier. |
| STR ioInterfaceAnalogueDescription_Sixth | 1.3.6.1.4.1.818.1.2.6.3.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this analogue line. |
| I32 ioInterfaceAnalogueStatus_Sixth | 1.3.6.1.4.1.818.1.2.6.3.2.1.3 | Integer32 | read-only | Read analogue value 1, when the board support such functionality |
| I32 ioInterfaceAnalogueLowThreshold_Sixth | 1.3.6.1.4.1.818.1.2.6.3.2.1.4 | Integer32 | read-write | Low limit for the analogical value. When the analogical measurement comes under this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueHighThreshold_Sixth | 1.3.6.1.4.1.818.1.2.6.3.2.1.5 | Integer32 | read-write | High limit for the analogical value. When the analogical measurement comes higher than this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueResetLowThreshold_Sixth | 1.3.6.1.4.1.818.1.2.6.3.2.1.6 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the low alarm condition (hysteresis) |
| I32 ioInterfaceAnalogueResetHighThreshold_Sixth | 1.3.6.1.4.1.818.1.2.6.3.2.1.7 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the high alarm condition (hysteresis) |
| ioInterfaceTraps_Sixth | 1.3.6.1.4.1.818.1.2.6.4 | |||
| NTF ioAlarmGenericChange_Sixth | 1.3.6.1.4.1.818.1.2.6.4.0.1 | An generic change of a digital input/digital output/analog input has become active. | ||
| ioInterface_Seventh | 1.3.6.1.4.1.818.1.2.7 | |||
| ioInterfaceInputLine_Seventh | 1.3.6.1.4.1.818.1.2.7.1 | |||
| NUM ioInterfaceNumInputs_Seventh | 1.3.6.1.4.1.818.1.2.7.1.1 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This entry indicates the number of rows in the input table. |
| ioInterfaceInputTable_Seventh | 1.3.6.1.4.1.818.1.2.7.1.2 | not-accessible | A list of input line table entries. The number of entries is given by the value of ioInterfaceNumInputs. | |
| ioInterfaceInputEntry_Seventh | 1.3.6.1.4.1.818.1.2.7.1.2.1 | not-accessible | An entry containing information applicable to a particular input line. | |
| NUM ioInterfaceInputLineIndex_Seventh | 1.3.6.1.4.1.818.1.2.7.1.2.1.1 | PositiveInteger32 | not-accessible | The input line identifier. |
| STR ioInterfaceInputDescription_Seventh | 1.3.6.1.4.1.818.1.2.7.1.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this input line. |
| INT ioInterfaceInputStatus_Seventh | 1.3.6.1.4.1.818.1.2.7.1.2.1.3 | INTEGER | read-only | The status of the input lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| INT ioInterfaceEdgeMode_Seventh | 1.3.6.1.4.1.818.1.2.7.1.2.1.4 | INTEGER | read-write | Edge mode for input lines. This object specifies if the corresponding input line should be recognised immediately as active (edge mode on), or only when the state remains stable for at least the time specified by ioInterfaceAlarmDelay (edge mode off). EdgeMode is only meaningful when the object ioInterfaceAlarmMask is active. |
| INT ioInterfaceAlarmMask_Seventh | 1.3.6.1.4.1.818.1.2.7.1.2.1.5 | INTEGER | read-write | Alarm functionality for the input line can be set active or inactive. |
| NUM ioInterfaceAlarmDelay_Seventh | 1.3.6.1.4.1.818.1.2.7.1.2.1.6 | NonNegativeInteger32 | read-write | Time delay during which an active input line has to be stable, prior to issue an alarm. Effective only when EdgeMode=off for the corresponding line. |
| ioInterfaceOutputLine_Seventh | 1.3.6.1.4.1.818.1.2.7.2 | |||
| NUM ioInterfaceNumOutput_Seventh | 1.3.6.1.4.1.818.1.2.7.2.1 | NonNegativeInteger32 | read-only | The number of output lines utilized by this device. This entry indicates the number of rows in the output line table. |
| ioInterfaceOutputTable_Seventh | 1.3.6.1.4.1.818.1.2.7.2.2 | not-accessible | A list of output line table entries. The number of entries is given by the value of ioInterfaceNumOutputs. | |
| ioInterfaceOutputEntry_Seventh | 1.3.6.1.4.1.818.1.2.7.2.2.1 | not-accessible | An entry containing information applicable to a particular output line. | |
| NUM ioInterfaceOutputLineIndex_Seventh | 1.3.6.1.4.1.818.1.2.7.2.2.1.1 | PositiveInteger32 | not-accessible | The output line identifier. |
| STR ioInterfaceOutputDescription_Seventh | 1.3.6.1.4.1.818.1.2.7.2.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this output line. |
| INT ioInterfaceOutputStatus_Seventh | 1.3.6.1.4.1.818.1.2.7.2.2.1.3 | INTEGER | read-write | The status of the output lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| ioInterfaceAnalogueLine_Seventh | 1.3.6.1.4.1.818.1.2.7.3 | |||
| NUM ioInterfaceNumAnalogue_Seventh | 1.3.6.1.4.1.818.1.2.7.3.1 | NonNegativeInteger32 | read-only | The number of analogue lines utilized by this device. This entry indicates the number of rows in the analogue line table. |
| ioInterfaceAnalogueTable_Seventh | 1.3.6.1.4.1.818.1.2.7.3.2 | not-accessible | A list of analogue line table entries. The number of entries is given by the value of ioInterfaceNumAnalogue. | |
| ioInterfaceAnalogueEntry_Seventh | 1.3.6.1.4.1.818.1.2.7.3.2.1 | not-accessible | An entry containing information applicable to a particular analogue line. | |
| NUM ioInterfaceAnalogueLineIndex_Seventh | 1.3.6.1.4.1.818.1.2.7.3.2.1.1 | PositiveInteger32 | not-accessible | The analogue line identifier. |
| STR ioInterfaceAnalogueDescription_Seventh | 1.3.6.1.4.1.818.1.2.7.3.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this analogue line. |
| I32 ioInterfaceAnalogueStatus_Seventh | 1.3.6.1.4.1.818.1.2.7.3.2.1.3 | Integer32 | read-only | Read analogue value 1, when the board support such functionality |
| I32 ioInterfaceAnalogueLowThreshold_Seventh | 1.3.6.1.4.1.818.1.2.7.3.2.1.4 | Integer32 | read-write | Low limit for the analogical value. When the analogical measurement comes under this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueHighThreshold_Seventh | 1.3.6.1.4.1.818.1.2.7.3.2.1.5 | Integer32 | read-write | High limit for the analogical value. When the analogical measurement comes higher than this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueResetLowThreshold_Seventh | 1.3.6.1.4.1.818.1.2.7.3.2.1.6 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the low alarm condition (hysteresis) |
| I32 ioInterfaceAnalogueResetHighThreshold_Seventh | 1.3.6.1.4.1.818.1.2.7.3.2.1.7 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the high alarm condition (hysteresis) |
| ioInterfaceTraps_Seventh | 1.3.6.1.4.1.818.1.2.7.4 | |||
| NTF ioAlarmGenericChange_Seventh | 1.3.6.1.4.1.818.1.2.7.4.0.1 | An generic change of a digital input/digital output/analog input has become active. | ||
| ioInterface_Eighth | 1.3.6.1.4.1.818.1.2.8 | |||
| ioInterfaceInputLine_Eighth | 1.3.6.1.4.1.818.1.2.8.1 | |||
| NUM ioInterfaceNumInputs_Eighth | 1.3.6.1.4.1.818.1.2.8.1.1 | NonNegativeInteger32 | read-only | The number of input lines utilized in this device. This entry indicates the number of rows in the input table. |
| ioInterfaceInputTable_Eighth | 1.3.6.1.4.1.818.1.2.8.1.2 | not-accessible | A list of input line table entries. The number of entries is given by the value of ioInterfaceNumInputs. | |
| ioInterfaceInputEntry_Eighth | 1.3.6.1.4.1.818.1.2.8.1.2.1 | not-accessible | An entry containing information applicable to a particular input line. | |
| NUM ioInterfaceInputLineIndex_Eighth | 1.3.6.1.4.1.818.1.2.8.1.2.1.1 | PositiveInteger32 | not-accessible | The input line identifier. |
| STR ioInterfaceInputDescription_Eighth | 1.3.6.1.4.1.818.1.2.8.1.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this input line. |
| INT ioInterfaceInputStatus_Eighth | 1.3.6.1.4.1.818.1.2.8.1.2.1.3 | INTEGER | read-only | The status of the input lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| INT ioInterfaceEdgeMode_Eighth | 1.3.6.1.4.1.818.1.2.8.1.2.1.4 | INTEGER | read-write | Edge mode for input lines. This object specifies if the corresponding input line should be recognised immediately as active (edge mode on), or only when the state remains stable for at least the time specified by ioInterfaceAlarmDelay (edge mode off). EdgeMode is only meaningful when the object ioInterfaceAlarmMask is active. |
| INT ioInterfaceAlarmMask_Eighth | 1.3.6.1.4.1.818.1.2.8.1.2.1.5 | INTEGER | read-write | Alarm functionality for the input line can be set active or inactive. |
| NUM ioInterfaceAlarmDelay_Eighth | 1.3.6.1.4.1.818.1.2.8.1.2.1.6 | NonNegativeInteger32 | read-write | Time delay during which an active input line has to be stable, prior to issue an alarm. Effective only when EdgeMode=off for the corresponding line. |
| ioInterfaceOutputLine_Eighth | 1.3.6.1.4.1.818.1.2.8.2 | |||
| NUM ioInterfaceNumOutput_Eighth | 1.3.6.1.4.1.818.1.2.8.2.1 | NonNegativeInteger32 | read-only | The number of output lines utilized by this device. This entry indicates the number of rows in the output line table. |
| ioInterfaceOutputTable_Eighth | 1.3.6.1.4.1.818.1.2.8.2.2 | not-accessible | A list of output line table entries. The number of entries is given by the value of ioInterfaceNumOutputs. | |
| ioInterfaceOutputEntry_Eighth | 1.3.6.1.4.1.818.1.2.8.2.2.1 | not-accessible | An entry containing information applicable to a particular output line. | |
| NUM ioInterfaceOutputLineIndex_Eighth | 1.3.6.1.4.1.818.1.2.8.2.2.1.1 | PositiveInteger32 | not-accessible | The output line identifier. |
| STR ioInterfaceOutputDescription_Eighth | 1.3.6.1.4.1.818.1.2.8.2.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this output line. |
| INT ioInterfaceOutputStatus_Eighth | 1.3.6.1.4.1.818.1.2.8.2.2.1.3 | INTEGER | read-write | The status of the output lines controlled by the device. When a bit is high (1), the associated line is 'active' |
| ioInterfaceAnalogueLine_Eighth | 1.3.6.1.4.1.818.1.2.8.3 | |||
| NUM ioInterfaceNumAnalogue_Eighth | 1.3.6.1.4.1.818.1.2.8.3.1 | NonNegativeInteger32 | read-only | The number of analogue lines utilized by this device. This entry indicates the number of rows in the analogue line table. |
| ioInterfaceAnalogueTable_Eighth | 1.3.6.1.4.1.818.1.2.8.3.2 | not-accessible | A list of analogue line table entries. The number of entries is given by the value of ioInterfaceNumAnalogue. | |
| ioInterfaceAnalogueEntry_Eighth | 1.3.6.1.4.1.818.1.2.8.3.2.1 | not-accessible | An entry containing information applicable to a particular analogue line. | |
| NUM ioInterfaceAnalogueLineIndex_Eighth | 1.3.6.1.4.1.818.1.2.8.3.2.1.1 | PositiveInteger32 | not-accessible | The analogue line identifier. |
| STR ioInterfaceAnalogueDescription_Eighth | 1.3.6.1.4.1.818.1.2.8.3.2.1.2 | DisplayString | read-write | A description of the alarm monitored by this analogue line. |
| I32 ioInterfaceAnalogueStatus_Eighth | 1.3.6.1.4.1.818.1.2.8.3.2.1.3 | Integer32 | read-only | Read analogue value 1, when the board support such functionality |
| I32 ioInterfaceAnalogueLowThreshold_Eighth | 1.3.6.1.4.1.818.1.2.8.3.2.1.4 | Integer32 | read-write | Low limit for the analogical value. When the analogical measurement comes under this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueHighThreshold_Eighth | 1.3.6.1.4.1.818.1.2.8.3.2.1.5 | Integer32 | read-write | High limit for the analogical value. When the analogical measurement comes higher than this limit, an alarm is issued. The limit can be disabled specifying the special floating point value which means 'not available'. |
| I32 ioInterfaceAnalogueResetLowThreshold_Eighth | 1.3.6.1.4.1.818.1.2.8.3.2.1.6 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the low alarm condition (hysteresis) |
| I32 ioInterfaceAnalogueResetHighThreshold_Eighth | 1.3.6.1.4.1.818.1.2.8.3.2.1.7 | Integer32 | read-write | After an alarm, value which has to be crossed by the analogue input, in order to remove the high alarm condition (hysteresis) |
| ioInterfaceTraps_Eighth | 1.3.6.1.4.1.818.1.2.8.4 | |||
| NTF ioAlarmGenericChange_Eighth | 1.3.6.1.4.1.818.1.2.8.4.0.1 | An generic change of a digital input/digital output/analog input has become active. | ||
| geModem | 1.3.6.1.4.1.818.1.3 | |||
| NUM geModemStatus | 1.3.6.1.4.1.818.1.3.1 | NonNegativeInteger32 | read-only | The status of the modem, controlled by the addressed device. The status word is a collection of bits, as specified below. The SNMP value NOSUCHNAME means 'status not (yet) available'. 1 modemStatOnline. There is a valid online connection. 2 modemStatError. The last operation has failed. The device will clear this bit when a new modem command is received. 4 unused (should be defined = 0). 8 unused (should be defined = 0). 16 modemStatDialling. The dialling procedure is pending. 32 modemStatBusy. The device is performing some operation, and can not be accessed, temporarily. 64 unused (should be defined = 0). 128 modemStatNoModem. The modem is not connected or not responding. 256 modemStatDCD. The DCD line status signal is on. 512 modemStatRing. The RING line status signal is on. 1024 modemStatCTS. The CTS line status signal is on. 2048 modemStatDSR. The DSR line status signal is on. 4096 unused (should be defined = 0). 8192 unused (should be defined = 0). 16384 unused (should be defined = 0). 32768 unused (should be defined = 0). |
| NUM geModemNumInitString | 1.3.6.1.4.1.818.1.3.2 | NonNegativeInteger32 | read-only | The number of modem init strings utilized by this ups. This entry indicates the number of rows in the init string table. |
| geModemInitStringTable | 1.3.6.1.4.1.818.1.3.3 | not-accessible | A list of init string table entries. The number of entries is given by the value of geModemNumInitString. | |
| geModemInitStringEntry | 1.3.6.1.4.1.818.1.3.3.1 | not-accessible | An entry containing information applicable to a particular Init string. | |
| NUM geModemInitStringLineIndex | 1.3.6.1.4.1.818.1.3.3.1.1 | PositiveInteger32 | not-accessible | The Init string line identifier. |
| STR geModemInitstring | 1.3.6.1.4.1.818.1.3.3.1.2 | DisplayString | read-write | A modem Init string. |
| NUM geModemNumPhoneNumber | 1.3.6.1.4.1.818.1.3.4 | NonNegativeInteger32 | read-only | The number of modem phone numbers utilized by this ups. This entry indicates the number of rows in the table. |
| geModemPhoneNumberTable | 1.3.6.1.4.1.818.1.3.5 | not-accessible | A list of phone number table entries. The number of entries is given by the value of geModemNumPhoneNumber. | |
| geModemPhoneNumberEntry | 1.3.6.1.4.1.818.1.3.5.1 | not-accessible | An entry containing information applicable to a particular phone number. | |
| NUM geModemPhoneNumberLineIndex | 1.3.6.1.4.1.818.1.3.5.1.1 | PositiveInteger32 | not-accessible | The phone number line identifier. |
| STR geModemPhoneNumber | 1.3.6.1.4.1.818.1.3.5.1.2 | DisplayString | read-write | A phone number. |
| geDevices | 1.3.6.1.4.1.818.1.100 | |||
| geDevicesDescriptions | 1.3.6.1.4.1.818.1.100.1 | |||
| advSNMPWebIntCard | 1.3.6.1.4.1.818.1.100.1.1 | |||
| snmpPWebIntCard | 1.3.6.1.4.1.818.1.100.1.2 | |||
| snmpWebIntBox | 1.3.6.1.4.1.818.1.100.1.3 | |||
| snmpSWPFAgent | 1.3.6.1.4.1.818.1.100.1.4 | |||
| snmpSWJUMPAgent | 1.3.6.1.4.1.818.1.100.1.5 | |||
| geSoftware | 1.3.6.1.4.1.818.2 | |||
| geClient | 1.3.6.1.4.1.818.2.1 | |||
| STR geClientProcessor | 1.3.6.1.4.1.818.2.1.1 | DisplayString | read-only | The processor used by the clients machine. |
| STR geClientOperatingSystem | 1.3.6.1.4.1.818.2.1.2 | DisplayString | read-only | Operating system on which the client runs. |
| STR geClientJavaRuntimeVersion | 1.3.6.1.4.1.818.2.1.3 | DisplayString | read-only | JavaRuntimeVersion of the client machine. |
| NUM geClientMaxSizeOfLogfiles | 1.3.6.1.4.1.818.2.1.4 | NonNegativeInteger32 | read-write | The max. size of the logfiles in Kb. |
| STR geClientLanguageSelection | 1.3.6.1.4.1.818.2.1.5 | DisplayString | read-only | Shows the currently activated language of the client. |
| NUM geClientInternalCommunicationPort | 1.3.6.1.4.1.818.2.1.6 | NonNegativeInteger32 | read-write | UDP port used between server and client part. |
| INT geClientReboot | 1.3.6.1.4.1.818.2.1.7 | INTEGER | write-only | setting this object causes the protection client to reboot and activate new settings. |
| NUM geClientNumUPS | 1.3.6.1.4.1.818.2.1.8 | NonNegativeInteger32 | read-only | The number of UPSs utilized by this client. This entry indicates the number of rows in the table. |
| geClientUPSTable | 1.3.6.1.4.1.818.2.1.9 | not-accessible | A list of UPS table entries. The number of entries is given by the value of geClientNumUPS. | |
| geClientUPSEntry | 1.3.6.1.4.1.818.2.1.9.1 | not-accessible | An entry containing information applicable to a particular UPS. | |
| NUM geClientUPSLineIndex | 1.3.6.1.4.1.818.2.1.9.1.1 | PositiveInteger32 | not-accessible | The UPS line identifier. |
| STR geClientUPSName | 1.3.6.1.4.1.818.2.1.9.1.2 | DisplayString | read-write | The administrative name of the UPS. |
| INT geClientUPSCommunicationType | 1.3.6.1.4.1.818.2.1.9.1.3 | INTEGER | read-write | The method of communication. |
| STR geClientUPSCommunicationPort | 1.3.6.1.4.1.818.2.1.9.1.4 | DisplayString | read-write | The communication port. |
| STR geClientUPSReadCommName | 1.3.6.1.4.1.818.2.1.9.1.5 | DisplayString | read-write | The Read community string. Used when communication method is SNMP. |
| STR geClientUPSWriteCommName | 1.3.6.1.4.1.818.2.1.9.1.6 | DisplayString | read-write | The Write community string. Used when communication method is SNMP. |
| NUM geClientUPSCommRetries | 1.3.6.1.4.1.818.2.1.9.1.7 | NonNegativeInteger32 | read-write | Number of retries in case an answer times out. When the max. number of retries is reached a lost communication alarm will be raised. |
| INT geClientAlarmManagement | 1.3.6.1.4.1.818.2.1.9.1.8 | INTEGER | read-write | Alarm Management enabled or disabled. |
| NUM geClientPreDelay | 1.3.6.1.4.1.818.2.1.9.1.9 | NonNegativeInteger32 | read-only | The number of second an alarm needs to be active before action is taken. |
| INT geClientSystemShutdown | 1.3.6.1.4.1.818.2.1.9.1.10 | INTEGER | read-only | Specifies whether the client should shutdown the machine when an alarm situation occurs. |
| NUM geClientRuntime | 1.3.6.1.4.1.818.2.1.9.1.11 | NonNegativeInteger32 | read-only | The user defined preferable runtime. |
| INT geClientUPSShutdown | 1.3.6.1.4.1.818.2.1.9.1.12 | INTEGER | read-only | Defines whether the UPS will be shut down after an Operating System shutdown. |
| NUM geClientMaxScriptExecutionTime | 1.3.6.1.4.1.818.2.1.9.1.13 | NonNegativeInteger32 | read-only | The max. number of seconds the script file is allowed to run. |
| NUM geClientGraceperiod | 1.3.6.1.4.1.818.2.1.9.1.14 | NonNegativeInteger32 | read-only | The time between start of the Operating System shutdown and the UPS shutdown. |
| NUM geClientNumTests | 1.3.6.1.4.1.818.2.1.20 | NonNegativeInteger32 | read-only | The number of scheduled tests. This entry indicates the number of rows in the table. |
| geClientTestTable | 1.3.6.1.4.1.818.2.1.21 | not-accessible | A list of test table entries. The number of entries is given by the value of geClientNumTests. | |
| geClientTestEntry | 1.3.6.1.4.1.818.2.1.21.1 | not-accessible | An entry containing information applicable to a particular Test. | |
| NUM geClientTestLineIndex | 1.3.6.1.4.1.818.2.1.21.1.1 | PositiveInteger32 | not-accessible | The test line identifier. |
| I32 geClientTestId | 1.3.6.1.4.1.818.2.1.21.1.2 | Integer32 | read-write | The test Id. |
| I32 geClientTestDayTime | 1.3.6.1.4.1.818.2.1.21.1.3 | Integer32 | read-write | The time on which the test is due to be performed. |
| I32 geClientTestWeekDay | 1.3.6.1.4.1.818.2.1.21.1.4 | Integer32 | read-write | The day in the week on which the test will be performed. |
| I32 geClientTestMonthDay | 1.3.6.1.4.1.818.2.1.21.1.5 | Integer32 | read-write | The month day on which the test will be performed. |
| NUM geClientNumShutdowns | 1.3.6.1.4.1.818.2.1.30 | NonNegativeInteger32 | read-only | The number of scheduled Shutdowns. This entry indicates the number of rows in the table. |
| geClientShutdownTable | 1.3.6.1.4.1.818.2.1.31 | not-accessible | A list of Shutdown table entries. The number of entries is given by the value of geClientNumShutdowns. | |
| geClientShutdownEntry | 1.3.6.1.4.1.818.2.1.31.1 | not-accessible | An entry containing information applicable to a particular Shutdown. | |
| NUM geClientShutdownLineIndex | 1.3.6.1.4.1.818.2.1.31.1.1 | PositiveInteger32 | not-accessible | The Shutdown line identifier. |
| I32 geClientShutdownDelay | 1.3.6.1.4.1.818.2.1.31.1.2 | Integer32 | read-write | The delay before start of the Shutdown. |
| I32 geClientShutdownDuration | 1.3.6.1.4.1.818.2.1.31.1.3 | Integer32 | read-write | The duration of the Shutdown. |
| I32 geClientShutdownDayTime | 1.3.6.1.4.1.818.2.1.31.1.4 | Integer32 | read-write | The time on which the Shutdown is due to be performed. |
| I32 geClientShutdownWeekDay | 1.3.6.1.4.1.818.2.1.31.1.5 | Integer32 | read-write | The day in the week on which the Shutdown will be performed. |
| I32 geClientShutdownMonthDay | 1.3.6.1.4.1.818.2.1.31.1.6 | Integer32 | read-write | The month day on which the Shutdown will be performed. |
| I32 geClientShutdownPreWarnTime | 1.3.6.1.4.1.818.2.1.31.1.7 | Integer32 | read-write | The number of seconds before start of the shutdown a pre warning will be raised. |
| geAgent | 1.3.6.1.4.1.818.3 | |||
| geAgentConfig | 1.3.6.1.4.1.818.3.1 | |||
| NUM geAgentUDPPort | 1.3.6.1.4.1.818.3.1.1 | NonNegativeInteger32 | read-write | The UDP port number used by agent. |
| NUM geAgentWebServerPort | 1.3.6.1.4.1.818.3.1.2 | NonNegativeInteger32 | read-write | The UDP port number used by the HTTP server. |
| STR geAgentComPort | 1.3.6.1.4.1.818.3.1.3 | DisplayString | read-write | The COM port used by the agent. |
| NUM geAgentComTimeout | 1.3.6.1.4.1.818.3.1.4 | NonNegativeInteger32 | read-write | The Timeout delay in seconds of the serial communication. |
| NUM geAgentComRetries | 1.3.6.1.4.1.818.3.1.5 | NonNegativeInteger32 | read-write | The number of retries when serial communication fails. |
| STR geAgentReadCommunity | 1.3.6.1.4.1.818.3.1.6 | DisplayString | read-write | The read community string of the agent. |
| STR geAgentWriteCommunity | 1.3.6.1.4.1.818.3.1.7 | DisplayString | read-write | The write community string of the agent. |
| STR geAgentResponsibleEmailAddress | 1.3.6.1.4.1.818.3.1.8 | DisplayString | read-write | The email address of the responsible person for this agent. |
| INT geRFCTrapsToSend | 1.3.6.1.4.1.818.3.1.9 | INTEGER | read-write | This object defines whether RFC traps need to be send. The bit value 1 indicates that the traps needs to be send, while value 0 does not result in a trap to send. |
| NUM geIMVTrapsToSend | 1.3.6.1.4.1.818.3.1.10 | NonNegativeInteger32 | read-write | This object defines for which device(s) IMV traps need to be send. The bit value 1 indicates that the trap needs to be send, while value 0 does not result in a trap to send. The value presents the devices as a mask: 1 GenericUPS 2 FirstUPS 4 SecondUPS 8 ThirdUPS 16 FourthUPS 32 FifthUPS 64 SixthUPS 128 SeventhUPS 256 EigthUPS 512 IOInterface |
| geAgentTraps | 1.3.6.1.4.1.818.3.2 | |||
| NUM geAgentNumTraps | 1.3.6.1.4.1.818.3.2.1 | NonNegativeInteger32 | read-only | The number of configured traps. This entry indicates the number of rows in the table. |
| geAgentTrapTable | 1.3.6.1.4.1.818.3.2.2 | not-accessible | A list of trap table entries. The number of entries is given by the value of geAgentNumTraps. | |
| geAgentTrapEntry | 1.3.6.1.4.1.818.3.2.2.1 | not-accessible | An entry containing information applicable to a particular trap target. | |
| NUM geAgentTrapLineIndex | 1.3.6.1.4.1.818.3.2.2.1.1 | PositiveInteger32 | not-accessible | The Trap line identifier. |
| STR geAgentTrapAddress | 1.3.6.1.4.1.818.3.2.2.1.2 | DisplayString | read-write | The destination IP-address of the trap. |
| STR geAgentTrapCommunity | 1.3.6.1.4.1.818.3.2.2.1.3 | DisplayString | read-write | The communication string used by the trap. |
| I32 geAgentTrapPort | 1.3.6.1.4.1.818.3.2.2.1.4 | Integer32 | read-write | The UDP port on the receiving side. |
RFC description
UPS system monitoring and control for General Electric parallel uninterruptible power supplies.
Start monitoring GE parallel-redundant UPS installation with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.