GE-PARALLELUPS :: upsTestSpinLock_second

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GE-PARALLELUPS › upsTestSpinLock_second

upsTestSpinLock_second

Module: GE-PARALLELUPS

OID (symbolic): GE-PARALLELUPS::upsTestSpinLock_second

OID (numeric): 1.3.6.1.4.1.818.1.1.12.7.2

Node type: OBJECT-TYPE

Type: TestAndIncr

Access: read-write

Description: A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try-again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock-value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock-value, upsTestId = requested-test) if (error-index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try-again } if (error-index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by polling upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock-value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1.(*)

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.818.1.1.12.7.2
snmpwalk -v2c -c public <target> GE-PARALLELUPS::upsTestSpinLock_second

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.818.1.1.12.7.2.1
snmpget -v2c -c public <target> GE-PARALLELUPS::upsTestSpinLock_second.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.818.1.1.12.7.2.1 s <value>

Start monitoring GE parallel-redundant UPS installation with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GE-PARALLELUPS::upsTestSpinLock_second OID value, configure state conditions and alerts, and monitor any GE parallel-redundant UPS installation from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.818imvGE-PARALLELUPS
1.3.6.1.4.1.818.1geHardwareGE-PARALLELUPS
1.3.6.1.4.1.818.1.1geUPSGE-PARALLELUPS
1.3.6.1.4.1.818.1.1.12geSecondUPSGE-PARALLELUPS
1.3.6.1.4.1.818.1.1.12.7upsTest_secondGE-PARALLELUPS
1.3.6.1.4.1.818.1.1.12.7.2upsTestSpinLock_secondGE-PARALLELUPS