GE-PARALLELUPS :: upsShutdownAfterDelay_seventh

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GE-PARALLELUPS › upsShutdownAfterDelay_seventh

upsShutdownAfterDelay_seventh

Module: GE-PARALLELUPS

OID (symbolic): GE-PARALLELUPS::upsShutdownAfterDelay_seventh

OID (numeric): 1.3.6.1.4.1.818.1.1.17.8.2

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.(*)

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.818.1.1.17.8.2
snmpwalk -v2c -c public <target> GE-PARALLELUPS::upsShutdownAfterDelay_seventh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.818.1.1.17.8.2.1
snmpget -v2c -c public <target> GE-PARALLELUPS::upsShutdownAfterDelay_seventh.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.818.1.1.17.8.2.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> upsShutdownAfterDelay_seventh.1

Start monitoring GE parallel-redundant UPS installation with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GE-PARALLELUPS::upsShutdownAfterDelay_seventh OID value, configure state conditions and alerts, and monitor any GE parallel-redundant UPS installation from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.818imvGE-PARALLELUPS
1.3.6.1.4.1.818.1geHardwareGE-PARALLELUPS
1.3.6.1.4.1.818.1.1geUPSGE-PARALLELUPS
1.3.6.1.4.1.818.1.1.17geSeventhUPSGE-PARALLELUPS
1.3.6.1.4.1.818.1.1.17.8upsControl_seventhGE-PARALLELUPS
1.3.6.1.4.1.818.1.1.17.8.2upsShutdownAfterDelay_seventhGE-PARALLELUPS