All MIBs › GE-PARALLELUPS › upsAlarmOnBatteryRestored_first
upsAlarmOnBatteryRestored_first
Module: GE-PARALLELUPS
OID (symbolic): GE-PARALLELUPS::upsAlarmOnBatteryRestored_first
OID (numeric): 1.3.6.1.4.1.818.1.1.11.11.0.34
Node type: NOTIFICATION-TYPE
Description: The UPS is drawing power from mains again.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' GE-PARALLELUPS::upsAlarmOnBatteryRestored_first snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.818.1.1.11.11.0.34
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:59974->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (37276230) 4 days, 7:32:42.30 SNMPv2-MIB::snmpTrapOID.0 = OID: GE-PARALLELUPS::upsAlarmOnBatteryRestored_first
SNMPv3 example:
snmptrap -v3 -l authPriv -u snmpv3user -a SHA -A "AuthPass1" -x AES -X "PrivPass1" <manager> '' GE-PARALLELUPS::upsAlarmOnBatteryRestored_first
Start monitoring GE parallel-redundant UPS installation with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GE-PARALLELUPS::upsAlarmOnBatteryRestored_first OID value, configure state conditions and alerts, and monitor any GE parallel-redundant UPS installation from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.818 | imv | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1 | geHardware | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1.1 | geUPS | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1.1.11 | geFirstUPS | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1.1.11.11 | geUPSTraps_first | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1.1.11.11.0.34 | upsAlarmOnBatteryRestored_first | GE-PARALLELUPS |