All MIBs › CADANT-CMTS-SYSTEM-MIB
Organization: ARRIS Group, Inc.
Last Updated: 2015-11-11
Category: DOCSIS and Cable, Device Management, Vendor: ARRIS
Description: Manages system-level configuration including software version, boot parameters, and system identity on ARRIS/Cadant CMTS equipment.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CADANT-CMTS-SYSTEM-MIB?
CADANT-CMTS-SYSTEM-MIB is an ARRIS proprietary MIB (successor to the Cadant name) defining system-wide DOCSIS timing and protocol parameters and constants on the Arris E6000 CMTS. Its objects configure synchronization interval, UCD (Upstream Channel Descriptor) interval, maximum pending MAPs, ranging interval, ranging/registration retry limits, and per-message processing-time constants used in DOCSIS cable-modem registration. As a configuration MIB it lets an administrator confirm the CMTS's DOCSIS timing parameters match vendor-recommended values when diagnosing cable-modem registration delays or failures. It is deployed on ARRIS E6000 CMTS platforms in cable operator head-ends. Engineers can download the CADANT-CMTS-SYSTEM-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in CADANT-CMTS-SYSTEM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- ARRIS E6000 CMTS
Monitoring Examples
An administrator checks cadSysRangingInterval and cadSysInvitedRangingRetries against recommended DOCSIS timing values when a batch of cable modems is taking unusually long to complete ranging and registration.
What Can Be Monitored
- DOCSIS timing intervals and registration retry limits
This MIB depends on
Related MIBs
Imported Objects
From CADANT-PRODUCTS-MIB
| cadSystem | OBJECT-IDENTITY |
From CADANT-TC
| AdminSrcAddrType | |
| AdminState | |
| CardId | |
| OverloadThreshold | |
| ServerType |
From DOCS-IF-MIB
| TenthdB |
From DOCS-QOS3-MIB
| BitRate |
From IF-MIB
| InterfaceIndexOrZero |
From INET-ADDRESS-MIB
| InetAddress | |
| InetAddressIPv4 | |
| InetAddressIPv6 | |
| InetAddressType |
From SNMP-FRAMEWORK-MIB
| SnmpAdminString | |
| SnmpEngineID |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| MacAddress | |
| RowStatus | |
| TruthValue |
How to Use in IPNetwork Monitor
Example using cadSysProcRouterControlGlobalPacketsReceivedPassed OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| cadSystemMib | 1.3.6.1.4.1.4998.1.1.5.1 | Arris E6000 system parameters and constants | ||
| cadSysParams | 1.3.6.1.4.1.4998.1.1.5.1.1 | |||
| I32 cadSysSyncInterval | 1.3.6.1.4.1.4998.1.1.5.1.1.1 | Integer32 | read-only | Nominal time between transmission of SYNC messages. (ref 6.3.2) |
| I32 cadSysUCDInterval | 1.3.6.1.4.1.4998.1.1.5.1.1.2 | Integer32 | read-only | Time between transmission of UCD messages. (ref 6.3.3) |
| I32 cadSysMaxMAPPending | 1.3.6.1.4.1.4998.1.1.5.1.1.3 | Integer32 | read-only | The number of mini-slots that a CMTS is allowed to map into the future. (ref 6.3.4) |
| I32 cadSysRangingInterval | 1.3.6.1.4.1.4998.1.1.5.1.1.4 | Integer32 | read-only | Time between transmission of broadcast Ranging requests. (ref 7.3.3) |
| I32 cadSysInvitedRangingRetries | 1.3.6.1.4.1.4998.1.1.5.1.1.5 | Integer32 | read-only | Number of retries on inviting ranging requests. (ref 9.2.4) |
| I32 cadSysRegistrationRequestRetries | 1.3.6.1.4.1.4998.1.1.5.1.1.6 | Integer32 | read-only | Number of retries on registration requests/responses. |
| I32 cadSysCMMAPProcessingTime | 1.3.6.1.4.1.4998.1.1.5.1.1.7 | Integer32 | read-only | Time provided between arrival of the last bit of a MAP at a CM and effectiveness of that MAP. (ref 7.1.1) |
| I32 cadSysCMRangingResponseProcessingTime | 1.3.6.1.4.1.4998.1.1.5.1.1.8 | Integer32 | read-only | Minimum tile allowed fro a CM following receipt of a rangin response before it is expected to reply to an invited ranging request. |
| I32 cadSysCMConfiguration | 1.3.6.1.4.1.4998.1.1.5.1.1.9 | Integer32 | read-write | Maximum time allowed for a CM, following receipt of a configuration file, to send a Registration Request to a CMTS. |
| I32 cadSysT5Timeout | 1.3.6.1.4.1.4998.1.1.5.1.1.10 | Integer32 | read-only | Wait for Upstream CHannel Change response. |
| I32 cadSysT6Timeout | 1.3.6.1.4.1.4998.1.1.5.1.1.11 | Integer32 | read-only | Wait for REG-RSP and REG-ACK |
| I32 cadSysMiniSlotSize | 1.3.6.1.4.1.4998.1.1.5.1.1.12 | Integer32 | read-only | Size of mini-slotfor upstream transmission. Must be a power of 2 (in units of the Timebase Tick). |
| I32 cadSysDSxRequestRetries | 1.3.6.1.4.1.4998.1.1.5.1.1.13 | Integer32 | read-only | Number of Timeout Retries on DSA/DSC/DSD Requests. |
| I32 cadSysDSxResponseRetries | 1.3.6.1.4.1.4998.1.1.5.1.1.14 | Integer32 | read-only | Number of Timeout Retries on DSA/DSC/DSD Responses. |
| I32 cadSysT7Timeout | 1.3.6.1.4.1.4998.1.1.5.1.1.15 | Integer32 | read-only | Wait for DSA/DSC/DSD Response timeout. |
| I32 cadSysT8Timeout | 1.3.6.1.4.1.4998.1.1.5.1.1.16 | Integer32 | read-only | Wait for DSA/DSC/DSD Acknowledge timeout. |
| I32 cadSysT9Timeout | 1.3.6.1.4.1.4998.1.1.5.1.1.17 | Integer32 | read-only | Registration timeout, the time allowed between the CMTS sending a RNG-RSP(success) to a CM, and receiving a REG-REQ from that same CM. |
| I32 cadSysT10Timeout | 1.3.6.1.4.1.4998.1.1.5.1.1.18 | Integer32 | read-only | Wait for Transaction End timeout. |
| I32 cadSysT11Timeout | 1.3.6.1.4.1.4998.1.1.5.1.1.19 | Integer32 | read-only | Wait for a DCC Response on the old channel. |
| I32 cadSysT13Timeout | 1.3.6.1.4.1.4998.1.1.5.1.1.20 | Integer32 | read-only | Maximum holding time for QOS resources for DCC. |
| I32 cadSysDCCREQRetries | 1.3.6.1.4.1.4998.1.1.5.1.1.21 | Integer32 | read-only | Number of retries on Dynamic Channel Change Request. |
| T/F cadSysMICEnable | 1.3.6.1.4.1.4998.1.1.5.1.1.22 | TruthValue | read-write | Enable MIC checking on the CMTS. |
| OCT cadSysMICAuthString | 1.3.6.1.4.1.4998.1.1.5.1.1.23 | OCTET STRING | read-write | Encrypted MIC Authentication |
| T/F cadSysAutoRecoveryEnable | 1.3.6.1.4.1.4998.1.1.5.1.1.24 | TruthValue | read-write | Enable automatic recovery of card/port/software in case of component failure. |
| IP cadSysActiveIpAddress | 1.3.6.1.4.1.4998.1.1.5.1.1.25 | IpAddress | read-write | Ip Address of the active control complex. |
| BIT cadSysSpOperMode | 1.3.6.1.4.1.4998.1.1.5.1.1.26 | Bits | read-write | Special operational mode. Value of 1 indicates the mode is enabled. dqossf10cms - Allow 1.0 CMs to be stored in DocsQosServiceFlowEntry adjrxpwrctl - Allow rx power control to be adjusted by mod type usage enbudptcpfltr - Allow combining of Udp and Tcp messages in a single filter upce - Allow Upstream Packet Classifier Enforcement use16ForDSPeakTrafficRate - use the defunct TLV type 16 for DS peak traffic rate cpeNacksForceCmReset - - Force CM reset upon receiving 3 consecutive CPE NACKs loadBalUnbondedVoipOn - Allow load balancing for non-bonded voice calls limitUsRngRspFreqOff - Prevent CM from using an upstream frequency beyond 42 MHz upDownTrapIfDescrOff - Allow linkup or linkdown trap to include ifDescr ofdmSparingCleanupOff - Allow automatically reset any D3.1 CMs in a cable-mac that has an OFDM channel on that DCAM in the CM's RCS after a failover or fallback cmstatusoperational - Support DOCS-IF-MIB draft-05 (cw26)'s change to docsIfCmtsCmStatusValue, such that online modems take on a value of operational(8) at the CMTS. If disabled, operational(8) is not used and online modems take on a value of registrationComplete(6) at the CMTS. docsis20test - Allow running of DOCSIS 2.0 Tests. showCmFormatCVOff - show cable modem is formatted per CableVision's requirements if set to 0. docsis10plusOff - DOCSIS 1.0+ support is enabled if set to 0. downstreamOverrideOn - downstream overrides are disabled if this is set to 0. supressDCDOff - DCDs are suppressed if set to 0. virtualCmOff - support for virtual modems is enabled if set to 0. bpiHybridOff - Allow DOCSIS 1.1 modems to operate in BPI instead of BPI+ if this is set to 0. oneDCmDSMaxTrafBurstOn - Override Max Traffic Burst for DOCSIS 1.1 modems on a 1D CAM with E6000 setting if this is set to 0. docsis30ReqTxPolicyChkOff - Override DOCSIS 3.0 checking for Request/Transmission Policy TLV on upstream flows. |
| U32 cadSysCountsCollectionRate | 1.3.6.1.4.1.4998.1.1.5.1.1.27 | Unsigned32 | read-write | The period, in minutes, in which every count in the CMTS is to be collected. If this object is set to 0, counts collection will be disabled. |
| I32 cadSysMaxQoSActiveTimeout | 1.3.6.1.4.1.4998.1.1.5.1.1.28 | Integer32 | read-write | Defines the maximum QoS Active Timeout the E6000 is willing to allow. If a larger value is received in a CM request the E6000 will return this value instead in the response (Reference DOCSIS RFI Section c.2.2.5.6). Note a value of 0 is infinite and is therefore treated as the largest value in the range. |
| I32 cadSysMaxQoSAdmittedTimeout | 1.3.6.1.4.1.4998.1.1.5.1.1.29 | Integer32 | read-write | Defines the maximum QoS Admitted Timeout the E6000 is willing to allow. If a larger value is received in a CM request the E6000 will return this value instead in the response (Reference DOCSIS RFI Section c.2.2.5.7). Note a value of 0 is infinite and is therefore treated as the largest value in the range. |
| T/F cadSysAllow10CmConcatenation | 1.3.6.1.4.1.4998.1.1.5.1.1.30 | TruthValue | read-write | Defines whether or not the E6000 will allow a modem operating in DOCSIS 1.0 mode to utilize concatenation. If this value is false and a modem operating in 1.0 mode sends up a modem capability indicating concatenation the E6000 will respond by turning that capability off. If this value is true the modem will be returned whatever it requests (on or off). |
| T/F cadSysAllow10CmFragmentation | 1.3.6.1.4.1.4998.1.1.5.1.1.31 | TruthValue | read-write | Defines whether or not the E6000 will allow a modem operating in DOCSIS 1.0 mode to utilize fragmentation. If this value is false and a modem operating in 1.0 mode sends up a modem capability indicating fragmentation the E6000 will respond by turning that capability off. If this value is true the modem will be returned whatever it requests (on or off). |
| I32 cadSysPercentAddtlDsBwAllocated | 1.3.6.1.4.1.4998.1.1.5.1.1.32 | Integer32 | read-write | This value of this setting is used to make a percentage increase to a dynamic downstream service flows maximum traffic rate. This is flexiblity actually causes the E6000 to operate outside the DOCSIS 1.1 specification by allocating and allowing more traffic than was actually requested. The initial reason for providing this capability is to mask problems produced in the Voice environment where devices have been seen to violate the traffic rates. Examples of this are MTAs that overuse the QI bit for long durations thus overdriving the downstream burst interval and the Neura IPDT gateway introducing an additional 0.5% inband signaling to the DS voice flow |
| I32 cadSysMaxTrafBurstFor11CMs | 1.3.6.1.4.1.4998.1.1.5.1.1.33 | Integer32 | read-write | This is the default value that will be used to populate the Maximum Traffic Burst for a 1.1 modem unless the maximum traffic burst TLV is explicitly provided in either the modems Request or in a Service Class Name definition. This value is being made programmable for 2 reasons: 1) So that it can be set to the DOCSIS default of 3044 for CableLabs testing and 2) it can be tuned for real world applications. |
| T/F cadSysFanSpeedControlEnable | 1.3.6.1.4.1.4998.1.1.5.1.1.34 | TruthValue | read-write | Enable automatic fan speed control. |
| TEN cadSysFlaplistPowerAdjustThreshold | 1.3.6.1.4.1.4998.1.1.5.1.1.35 | TenthdB | read-write | The threshold is used to monitor the power adjust in the flap list. For a range request received that results in a power adjust exceeding the threshold value will cause the counter cadIfCmtsCmCountsPowerAdjExceedsThreshold to be incremented. If the threshold is set to 0, the monitoring of power adjustment in the flap list is disabled. |
| T/F cadSysRemoteFSEnable | 1.3.6.1.4.1.4998.1.1.5.1.1.36 | TruthValue | read-write | Indicates whether the active SCM should allow mounting the the filesystems of the standby SCM. |
| T/F cadSysRemotePortEnable | 1.3.6.1.4.1.4998.1.1.5.1.1.37 | TruthValue | read-write | Indicates whether the active SCM should allow redirection of the serial console of the standby SCM. |
| U32 cadSysTcpSmoothingValue1D8U | 1.3.6.1.4.1.4998.1.1.5.1.1.38 | Unsigned32 | read-write | TCP smoothing value to be programmed into hardware on 1D8U CAMs. |
| U32 cadSysTcpSmoothingValue2D12U | 1.3.6.1.4.1.4998.1.1.5.1.1.39 | Unsigned32 | read-write | TCP smoothing value to be programmed into hardware on 2D12U CAMs. |
| U32 cadSysModemLossThreshold | 1.3.6.1.4.1.4998.1.1.5.1.1.40 | Unsigned32 | read-write | Minimum modem threshold triggering detection of an upstream channel lockup. |
| BIT cadSysPeakTrafRateFor11CMs | 1.3.6.1.4.1.4998.1.1.5.1.1.41 | BitRate | read-write | This is the default value that will be used to populate the Peak Traffic Rate for a 1.1 modem configuration file unless the peak traffic rate is explicitly provided by a Service Class Name definition. |
| T/F cadSysCpeHostAuthorization | 1.3.6.1.4.1.4998.1.1.5.1.1.44 | TruthValue | read-write | This variable enables the CPE Host Authorization feature. |
| I32 cadSysMaxUcdBurstLength | 1.3.6.1.4.1.4998.1.1.5.1.1.46 | Integer32 | read-write | This variable limits the maximum UCD burst length. |
| T/F cadSysLO1LeakDetect | 1.3.6.1.4.1.4998.1.1.5.1.1.47 | TruthValue | read-write | This variable controls LO1 leak detection on the DMM. |
| T/F cadMtcmConditionalOverride | 1.3.6.1.4.1.4998.1.1.5.1.1.48 | TruthValue | read-write | If set to 'true', for a MAC Domain configured for MTCM enabled operation, the E6000 will set a registering MTCM-capable CM to be MTCM disabled (via REG-RSP message) unless at least one of the config file's service flows was specifically configured to have the Bonded bit set in the Required attribute mask (in which case the CM will be set to MTCM enabled). If set to false, standard DOCSIS 3.0 operation will result. |
| T/F cadSysDelayedCpeLearning | 1.3.6.1.4.1.4998.1.1.5.1.1.49 | TruthValue | read-write | This setting only applies to modems that have BPI enabled. When set to false(2), CPE learning is enabled during registration when BPI initialization is initiated for those modems using BPI. When set to true(1), CPE learning is delayed during registration until BPI initialization is complete for those modems using BPI. For modems not using BPI, CPE learning is enabled when registration is complete. |
| T/F cadSysModPriDsInRccEnabled | 1.3.6.1.4.1.4998.1.1.5.1.1.52 | TruthValue | read-write | Enable modifying primary Downstream channel in RCC of Reg-Rsp-MP. Refer ECN 690. |
| T/F cadSysSendTccRefIdPerFragment | 1.3.6.1.4.1.4998.1.1.5.1.1.53 | TruthValue | read-write | Settings for sending the Transmit Channel Configuration (TCC) Reference sub-type 46.1 for type 46 TCC fragmentation. If 'true', sends 46.1 Ref ID in every type 46 TCC fragment; If 'false', only sends 46.1 Ref ID in the first TCC fragment (DOCSIS Compliant). |
| T/F cadSysPeakTrRateUpstream | 1.3.6.1.4.1.4998.1.1.5.1.1.54 | TruthValue | read-write | This object enables support for Peak Traffic Rate in the upstream direction. |
| T/F cadSysAllowAmbiguityOverride | 1.3.6.1.4.1.4998.1.1.5.1.1.55 | TruthValue | read-write | This object enables ambiguity resolution channel-override actions. |
| T/F cadSysUnicastNpUsAcquisition | 1.3.6.1.4.1.4998.1.1.5.1.1.56 | TruthValue | read-write | This object enables unicast non-primary upstream channel acquisition. |
| T/F cadSysMacMoveBlockedOnRcptDhcpPkt | 1.3.6.1.4.1.4998.1.1.5.1.1.57 | TruthValue | read-write | MAC movement is blocked on receipt of DHCP packets |
| INT cadSysTftpProxy | 1.3.6.1.4.1.4998.1.1.5.1.1.58 | INTEGER | read-write | This parameter provides a global enable for the TFTP Enforce and Dynamic Shared Secret features. In order for the cadIfMacDomainTftpEnforce and cadIfMacDomainDynamicSecret parameters to take effect, this parameter must also be enabled. This parameter can also limit those features to only IPv4 transfers or IPv6 transfers. |
| I32 cadSysFanSpeedLevel | 1.3.6.1.4.1.4998.1.1.5.1.1.59 | Integer32 | read-write | Set the fan speed for the chassis. |
| T/F cadSys1x1onCmAcPwrLossEnabled | 1.3.6.1.4.1.4998.1.1.5.1.1.60 | TruthValue | read-write | This object enables/disables the CMTS reaction to a AC Power Loss CM-STATUS. If true, the CMTS will wait until cadSys1x1onCmAcPwrLossHoldoff expires, and then the CMTS will place the CM into a 1x1 (US/DS) channel mode to conserve CM battery power. If false, the CMTS will not place a CM that reports an AC Power Loss into 1x1 mode. |
| I32 cadSysFlapListInsertionThreshold | 1.3.6.1.4.1.4998.1.1.5.1.1.61 | Integer32 | read-write | This object shows the number of seconds between successive ranging attempts that must pass before the modem is counted as flapped. The modem must have also been in a provisioning or registered state before the ranging request. |
| T/F cadSysAES128Enable | 1.3.6.1.4.1.4998.1.1.5.1.1.62 | TruthValue | read-write | Enables AES-128 Cryptography Suite for BPI+ when true. |
| cadSysSystem | 1.3.6.1.4.1.4998.1.1.5.1.2 | |||
| STR cadSysContact | 1.3.6.1.4.1.4998.1.1.5.1.2.1 | DisplayString | read-only | The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
| STR cadSysName | 1.3.6.1.4.1.4998.1.1.5.1.2.2 | DisplayString | read-only | An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
| STR cadSysLocation | 1.3.6.1.4.1.4998.1.1.5.1.2.3 | DisplayString | read-only | The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. |
| cadSysControl | 1.3.6.1.4.1.4998.1.1.5.1.3 | |||
| T/F cadSysWriteMem | 1.3.6.1.4.1.4998.1.1.5.1.3.1 | TruthValue | read-write | This variable always returns FALSE upon reading. When set to TRUE, the configuration data currently resident in volatile memory (RAM) is written to persistent memory (NVRAM). |
| T/F cadSysEraseMem | 1.3.6.1.4.1.4998.1.1.5.1.3.2 | TruthValue | read-write | This variable always returns FALSE upon reading. When set to TRUE, the configuration data currently resident in persistent memory (NVRAM) is erased. |
| cadSysSnmp | 1.3.6.1.4.1.4998.1.1.5.1.4 | |||
| INT cadSysEnableAuthenTraps | 1.3.6.1.4.1.4998.1.1.5.1.4.1 | INTEGER | read-write | Indicates whether the SNMP entity is permitted to generate authentication traps. |
| U32 cadSysSnmpReadAheadMax | 1.3.6.1.4.1.4998.1.1.5.1.4.2 | Unsigned32 | read-write | This value is the maximum number of records to read ahead |
| U32 cadSysSnmpRefreshTime | 1.3.6.1.4.1.4998.1.1.5.1.4.3 | Unsigned32 | read-write | This value represents how old a database record can be to be used. |
| cadSnmpRemoteEngineTable | 1.3.6.1.4.1.4998.1.1.5.1.4.4 | not-accessible | Table containing information of remote SNMP engines. | |
| cadSnmpRemoteEngineEntry | 1.3.6.1.4.1.4998.1.1.5.1.4.4.1 | not-accessible | Entry containing information of remote SNMP engines. | |
| IP cadSnmpRemoteEngineIpAddress | 1.3.6.1.4.1.4998.1.1.5.1.4.4.1.1 | IpAddress | not-accessible | The IP address of a remote SNMP engine with which this user can communicate. |
| I32 cadSnmpRemoteEnginePortNumber | 1.3.6.1.4.1.4998.1.1.5.1.4.4.1.2 | Integer32 | not-accessible | The UDP port of a remote SNMP engine with which this user can communicate. |
| SNM cadSnmpRemoteEngineID | 1.3.6.1.4.1.4998.1.1.5.1.4.4.1.3 | SnmpEngineID | read-create | An SNMP engine's administratively-unique identifier of a remote SNMP engine with which this user can communicate. |
| STR cadSnmpRemoteUserName | 1.3.6.1.4.1.4998.1.1.5.1.4.4.1.4 | SnmpAdminString | read-create | A human readable string representing the name of the user of a remote SNMP engine. |
| INT cadSnmpRemoteEngineType | 1.3.6.1.4.1.4998.1.1.5.1.4.4.1.5 | INTEGER | read-only | The type to indicate the remote engineID is manually configured or internally detected via SNMP V3 Informs probe response. |
| ROW cadSnmpRemoteEngineStatus | 1.3.6.1.4.1.4998.1.1.5.1.4.4.1.6 | RowStatus | read-create | The status of this conceptual row. |
| cadSysBootParams | 1.3.6.1.4.1.4998.1.1.5.1.5 | |||
| MAC cadSysBootMacAddress | 1.3.6.1.4.1.4998.1.1.5.1.5.1 | MacAddress | read-only | Mac address of system controller |
| IP cadSysBootFpIpAddress | 1.3.6.1.4.1.4998.1.1.5.1.5.2 | IpAddress | read-write | Ip address of E6000 front panel ethernet port |
| IP cadSysBootFpSubnetMask | 1.3.6.1.4.1.4998.1.1.5.1.5.3 | IpAddress | read-write | E6000 front port interface subnet mask |
| IP cadSysBootDefaultGateway | 1.3.6.1.4.1.4998.1.1.5.1.5.6 | IpAddress | read-write | Default gateway |
| I32 cadSysBootTimeOffset | 1.3.6.1.4.1.4998.1.1.5.1.5.7 | Integer32 | read-only | Time offset (seconds) from UTC |
| IP cadSysBootTimeServer | 1.3.6.1.4.1.4998.1.1.5.1.5.8 | IpAddress | read-only | Ip address of TOD server |
| INT cadSysBootTimeServerConnType | 1.3.6.1.4.1.4998.1.1.5.1.5.9 | INTEGER | read-only | Protocol (tcp/udp) used to connect to TOD server |
| INT cadSysBootStartupApplication | 1.3.6.1.4.1.4998.1.1.5.1.5.10 | INTEGER | read-only | Startup mode of the E6000 |
| I32 cadSysBootStartupDelay | 1.3.6.1.4.1.4998.1.1.5.1.5.11 | Integer32 | read-only | Delay (in seconds) allowing changes before booting application |
| I32 cadSysBootSelection | 1.3.6.1.4.1.4998.1.1.5.1.5.12 | Integer32 | read-only | Bootloader to use (1 or 2) |
| I32 cadSysBootBaud | 1.3.6.1.4.1.4998.1.1.5.1.5.13 | Integer32 | read-only | Baud rate of front panel serial port |
| IP cadSysBootFpBIpAddress | 1.3.6.1.4.1.4998.1.1.5.1.5.15 | IpAddress | read-write | Ip address of E6000 side B front panel ethernet port |
| OCT cadSysBootParity | 1.3.6.1.4.1.4998.1.1.5.1.5.16 | OCTET STRING | read-only | Serial parity of console port. Valid values are N (no parity), E (even parity), and O (odd parity). |
| cadSysReload | 1.3.6.1.4.1.4998.1.1.5.1.6 | |||
| INT cadSysReloadOperation | 1.3.6.1.4.1.4998.1.1.5.1.6.1 | INTEGER | read-write | Control object for E6000 reload, reading this object always returns none(99) |
| STR cadSysReloadImageName | 1.3.6.1.4.1.4998.1.1.5.1.6.2 | DisplayString | read-write | Image name to use in reloadImage operation |
| BIT cadSysReloadStatus | 1.3.6.1.4.1.4998.1.1.5.1.6.3 | Bits | read-only | Status object for E6000 reload |
| STR cadSysReloadStatusDescription | 1.3.6.1.4.1.4998.1.1.5.1.6.4 | DisplayString | read-write | Textual description of reload status |
| STR cadSysReloadPatchName | 1.3.6.1.4.1.4998.1.1.5.1.6.5 | DisplayString | read-write | Patch image name to use in patch operations |
| cadSysImage | 1.3.6.1.4.1.4998.1.1.5.1.7 | |||
| STR cadSysImageFile | 1.3.6.1.4.1.4998.1.1.5.1.7.1 | DisplayString | read-only | Image filename for current E6000 image |
| I32 cadSysImageId | 1.3.6.1.4.1.4998.1.1.5.1.7.2 | Integer32 | read-only | Image identifier for current E6000 image |
| STR cadSysImageName | 1.3.6.1.4.1.4998.1.1.5.1.7.3 | DisplayString | read-only | Image name for current E6000 image |
| I32 cadSysImageComponentCount | 1.3.6.1.4.1.4998.1.1.5.1.7.4 | Integer32 | read-only | Image component count for current E6000 image |
| cadSysDictionary | 1.3.6.1.4.1.4998.1.1.5.1.8 | |||
| cadSysDictionaryTable | 1.3.6.1.4.1.4998.1.1.5.1.8.1 | not-accessible | Table describing internal state of database. | |
| cadSysDictionaryEntry | 1.3.6.1.4.1.4998.1.1.5.1.8.1.1 | not-accessible | Describes the internal state of an individual table. | |
| U32 cadSysDictionaryTableId | 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.1 | Unsigned32 | not-accessible | Internal identifier for this MIB data. |
| STR cadSysDictionaryName | 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.2 | DisplayString | read-only | Internal name for this MIB data. |
| T/F cadSysDictionaryDynamic | 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.3 | TruthValue | read-only | Indicates whether table is persistent or volatile only. |
| I32 cadSysDictionaryNumberEntries | 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.4 | Integer32 | read-only | Current number of rows contained in the MIB table. |
| U32 cadSysDictionaryCurrentVer | 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.5 | Unsigned32 | read-only | Current internal dynamic version number of the MIB table. |
| U32 cadSysDictionaryPersistentVer | 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.6 | Unsigned32 | read-only | Current internal version number of the MIB table on flash. |
| U32 cadSysDictionaryModuleVer | 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.7 | Unsigned32 | read-only | Current internal version number of the schema of the MIB table. |
| cadSysConfiguration | 1.3.6.1.4.1.4998.1.1.5.1.9 | |||
| DAT cadSysConfigSaveTime | 1.3.6.1.4.1.4998.1.1.5.1.9.1 | DateAndTime | read-only | The date and time of the last write of the configuration to nvram. |
| cadCosToQosMapping | 1.3.6.1.4.1.4998.1.1.5.1.10 | |||
| cadCosToQosMappingTable | 1.3.6.1.4.1.4998.1.1.5.1.10.9 | not-accessible | Table of COS to QOS Mapping data | |
| cadCosToQosMappingEntry | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1 | not-accessible | This entry contains all of the data to map 1.0 COS to 1.1 QOS parameters. | |
| I32 cadCosToQosMappingIndex | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.1 | Integer32 | not-accessible | The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMaxTrafficBurst |
| U32 cadCosUpMaxTrafficBurst | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.2 | Unsigned32 | read-write | The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMaxTrafficBurst |
| U32 cadCosDnMaxTrafficBurst | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.3 | Unsigned32 | read-write | The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMaxTrafficBurst |
| BIT cadCosDnMinReservedRate | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.4 | BitRate | read-write | The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMinReservedRate |
| I32 cadCosUpMinReservedPkt | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.5 | Integer32 | read-write | The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMinReservedPkt |
| I32 cadCosDnMinReservedPkt | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.6 | Integer32 | read-write | The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMinReservedPkt |
| OCT cadCosUpTosAndMask | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.7 | OCTET STRING | read-write | The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetTosAndMask |
| OCT cadCosUpTosOrMask | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.8 | OCTET STRING | read-write | The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetTosOrMask |
| U32 cadCosDnMaxLatency | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.9 | Unsigned32 | read-write | The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMaxLatency |
| I32 cadCosDnPriority | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.10 | Integer32 | read-write | The downstream channel priority to use. A -1 indicates that the current method of using the upstream channel priority should be used. |
| BIT cadCosDnPeakTrafficRate | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.11 | BitRate | read-write | Peak traffic rate shaped to while traffic still conforms to the policing parameters (Tmax and Burst). If the peak rate is set to a value greater than Tmax, then the traffic will be shaped to the peak rate until the traffic is non-conforming to the policing parameters, and then the traffic will be shaped to the Tmax rate. If the peak rate is less than the Tmax for a flow, then all traffic for that flow will shaped to the Tmax rate. Setting the peak rate to a value of 0 will result in all flows being limited to Tmax at all times. Setting the peak rate to a value of 0xffffffff will result in flows having virtually unlimited bandwidth until their burst size is used up. This parameter only has meaning for flows on downstreams that are shaped. |
| BIT cadCosUpPeakTrafficRate | 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.12 | BitRate | read-write | Peak traffic rate shaped to while traffic still conforms to the policing parameters (Tmax and Burst). If the peak rate is set to a value greater than Tmax, then the traffic will be shaped to the peak rate until the traffic is non-conforming to the policing parameters, and then the traffic will be shaped to the Tmax rate. If the peak rate is less than the Tmax for a flow, then all traffic for that flow will shaped to the Tmax rate. Setting the peak rate to a value of 0 will result in all flows being limited to Tmax at all times. Setting the peak rate to a value of 0xffffffff will result in flows having virtually unlimited bandwidth until their burst size is used up. This parameter only has meaning for upstream flows. |
| cadSysKeyChain | 1.3.6.1.4.1.4998.1.1.5.1.11 | |||
| cadSysKeyChainKeyTable | 1.3.6.1.4.1.4998.1.1.5.1.11.1 | not-accessible | Table describing key-chain key provisioned data. | |
| cadSysKeyChainKeyEntry | 1.3.6.1.4.1.4998.1.1.5.1.11.1.1 | not-accessible | Describes the provisioned data for a key in a key-chain. | |
| OCT cadSysKeyChainName | 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.1 | OCTET STRING | not-accessible | The key-chain name. |
| U32 cadSysKeyChainKeySequenceId | 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.2 | Unsigned32 | not-accessible | The sequence id of the key. |
| OCT cadSysKeyChainKey | 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.3 | OCTET STRING | read-create | The key string. |
| DAT cadSysKeyChainKeyAcceptStartTime | 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.4 | DateAndTime | read-create | The start time when this key is valid for received packets. |
| DAT cadSysKeyChainKeyAcceptStopTime | 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.5 | DateAndTime | read-create | The stop time when this key is no longer valid for received packets. |
| T/F cadSysKeyChainKeyAcceptInfiniteLifetime | 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.6 | TruthValue | read-create | If this value is set to true, the key has an infinite lifetime for received packets. Otherwise use the accept start and stop time to determine the lifetime. |
| DAT cadSysKeyChainKeySendStartTime | 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.7 | DateAndTime | read-create | The start time when this key is valid for sending packets. |
| DAT cadSysKeyChainKeySendStopTime | 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.8 | DateAndTime | read-create | The stop time when this key is no longer valid for sending packets. |
| T/F cadSysKeyChainKeySendInfiniteLifetime | 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.9 | TruthValue | read-create | If this value is set to true, the key has an infinite lifetime for sending packets. Otherwise use the send start and stop time to determine the lifetime. |
| ROW cadSysKeyChainKeyRowStatus | 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.10 | RowStatus | read-create | The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted. |
| cadSystemMibConformance | 1.3.6.1.4.1.4998.1.1.5.1.12 | |||
| cadSystemCompliances | 1.3.6.1.4.1.4998.1.1.5.1.12.1 | |||
| cadSystemCompliance | 1.3.6.1.4.1.4998.1.1.5.1.12.1.1 | Compliance statement for entities implementing the Cadant System Mib. | ||
| cadSystemGroups | 1.3.6.1.4.1.4998.1.1.5.1.12.2 | |||
| cadSysParamsGroup | 1.3.6.1.4.1.4998.1.1.5.1.12.2.1 | System parameter objects | ||
| cadSysSystemGroup | 1.3.6.1.4.1.4998.1.1.5.1.12.2.2 | System description objects | ||
| cadSysControlGroup | 1.3.6.1.4.1.4998.1.1.5.1.12.2.3 | System control objects | ||
| cadSysSnmpGroup | 1.3.6.1.4.1.4998.1.1.5.1.12.2.4 | System snmp control object | ||
| cadSysBootParamsGroup | 1.3.6.1.4.1.4998.1.1.5.1.12.2.5 | System boot parameters objects | ||
| cadSysReloadGroup | 1.3.6.1.4.1.4998.1.1.5.1.12.2.6 | System reload control objects | ||
| cadSysImageGroup | 1.3.6.1.4.1.4998.1.1.5.1.12.2.7 | System image status objects | ||
| cadSysConfigurationGroup | 1.3.6.1.4.1.4998.1.1.5.1.12.2.8 | Configuration objects | ||
| cadSysDataServerGroup | 1.3.6.1.4.1.4998.1.1.5.1.12.2.9 | Configuration objects | ||
| cadSysSourceAddressGroup | 1.3.6.1.4.1.4998.1.1.5.1.12.2.10 | Source Interface objects. | ||
| cadSysProcPolicingConfig | 1.3.6.1.4.1.4998.1.1.5.1.13 | |||
| U32 cadSysProcRouterControlGlobalPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.1 | Unsigned32 | read-write | The maximum permitted global protocol packet throttle rate to the Router Control processor. |
| U32 cadSysProcArpPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.2 | Unsigned32 | read-write | The maximum permitted ARP packet rate to the Router Control processor. |
| U32 cadSysProcDhcpPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.3 | Unsigned32 | read-write | The maxmimu permitted DHCP packet rate to the Router Control processor. |
| U32 cadSysProcIcmpPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.4 | Unsigned32 | read-write | The maximum permitted ICMP(IPv4) packet rate to the Router Control processor. |
| U32 cadSysProcOspfPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.5 | Unsigned32 | read-write | The maximum permitted OSPFv2 packet rate to the Router Control processor. |
| U32 cadSysProcRipPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.6 | Unsigned32 | read-write | The maximum permitted RIP packet rate to the Router Control processor. |
| U32 cadSysProcIgmpPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.7 | Unsigned32 | read-write | The maximum permitted IGMP packet rate to the Router Control processor. |
| U32 cadSysProcRouterControlOtherPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.8 | Unsigned32 | read-write | The other protocol packet rate to the Router Control processor. |
| U32 cadSysProcSnmpPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.10 | Unsigned32 | read-write | The SNMP packet rate to the System Control processor. |
| U32 cadSysProcTftpPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.11 | Unsigned32 | read-write | The TFTP packet rate to the processor. |
| U32 cadSysProcIsisPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.12 | Unsigned32 | read-write | The IS-IS packet rate to the processor. |
| U32 cadSysProcNdPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.13 | Unsigned32 | read-write | The maximum permitted Neighbor Discover (ND) packet throttle rate to the Router Control processor. This includes IPv6 Router Solicitation, Router Advertise, Neighbor Solicitation, Neighbor Advertise, and Redirect messages. |
| U32 cadSysProcDhcpIpv6PacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.14 | Unsigned32 | read-write | The maximum permitted DHCP (Ipv6) packet throttle rate to the Router Control processor. |
| U32 cadSysProcIcmpIpv6PacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.15 | Unsigned32 | read-write | The maximum permitted ICMP (Ipv6 other than Neighbor Discover and MLD) packet throttle rate to the Router Control processor. |
| U32 cadSysProcMldPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.16 | Unsigned32 | read-write | The maximum permitted MLD (version 1 and version 2) packet throttle rate to the Router Control processor. |
| U32 cadSysProcBgpPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.17 | Unsigned32 | read-write | The maximum permitted BGP packet throttle rate to the Router Control processor. |
| U32 cadSysProcPimPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.18 | Unsigned32 | read-write | The maximum permitted PIM packet throttle rate to the Router Control processor. |
| U32 cadSysProcSnmpCmPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.19 | Unsigned32 | read-write | The maximum permitted SNMP (from CMs) packet throttle rate to the Router Control processor. |
| U32 cadSysProcCopsPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.20 | Unsigned32 | read-write | The maximum permitted Cops packet throttle rate to the Router Control processor. |
| U32 cadSysProcTelnetPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.21 | Unsigned32 | read-write | The maximum permitted Telnet packet throttle rate to the Router Control processor. |
| U32 cadSysProcOspfv3PacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.22 | Unsigned32 | read-write | The maximum permitted OSPFv3 packet rate to the Router Control processor. |
| U32 cadSysProcTftpIpv6PacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.23 | Unsigned32 | read-write | The TFTP (IPv6) packet rate to the processor. |
| U32 cadSysProcEventIcmpPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.24 | Unsigned32 | read-write | The maximum permitted ICMP event packet rate to the Router Control processor. |
| U32 cadSysProcEventNoRoutePacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.25 | Unsigned32 | read-write | The maximum permitted No Route event packet rate to the Router Control processor. |
| U32 cadSysProcEventIcmpIpv6PacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.26 | Unsigned32 | read-write | The maximum permitted ICMP (IPv6) event packet rate to the Router Control processor. |
| U32 cadSysProcEventNoRouteIpv6PacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.27 | Unsigned32 | read-write | The maximum permitted No Route (IPv6) event packet rate to the Router Control processor. |
| U32 cadSysProcEventArpPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.28 | Unsigned32 | read-write | The maximum permitted ARP event packet rate to the Router Control processor. |
| U32 cadSysProcEventNdPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.29 | Unsigned32 | read-write | The maximum permitted ND event packet rate to the Router Control processor. |
| U32 cadSysProcEventTtlPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.30 | Unsigned32 | read-write | The maximum permitted TTL event packet rate to the Router Control processor. |
| U32 cadSysProcEventTtlIpv6PacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.31 | Unsigned32 | read-write | The maximum permitted TTL (IPv6) event packet rate to the Router Control processor. |
| U32 cadSysProcEventDadPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.32 | Unsigned32 | read-write | The maximum permitted DAD event packet rate to the Router Control processor. |
| U32 cadSysProcEventDefaultPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.33 | Unsigned32 | read-write | The maximum permitted Default event packet rate to the Router Control processor. |
| U32 cadSysProcLdpPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.34 | Unsigned32 | read-write | The LDP (UDP and TCP) packet rate to the processor. |
| T/F cadSysProcClearPolicingCounts | 1.3.6.1.4.1.4998.1.1.5.1.13.35 | TruthValue | read-write | This variable always returns false(2) upon reading. When set to true(1), all objects under cadSysProcPolicingCounts are cleared. |
| U32 cadSysProcLacpPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.36 | Unsigned32 | read-write | The total LACP packet rate to the processor. |
| U32 cadSysProcVrepPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.37 | Unsigned32 | read-write | The maximum permitted D6/VREP packet rate to the processor. |
| U32 cadSysProcVpmePacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.38 | Unsigned32 | read-write | The maximum permitted VPME packet rate to the processor. |
| U32 cadSysProcErmRpcPacketRate | 1.3.6.1.4.1.4998.1.1.5.1.13.39 | Unsigned32 | read-write | The maximum permitted RPC packet rate from an RPC ERM processor. |
| cadSysProcPolicingCounts | 1.3.6.1.4.1.4998.1.1.5.1.14 | |||
| C32 cadSysProcRouterControlGlobalPacketsReceivedPassedEx | 1.3.6.1.4.1.4998.1.1.5.1.14.1 | Counter32 | read-only | The number of packets received passed to the Router Control processor. |
| C32 cadSysProcRouterControlGlobalPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.2 | Counter32 | read-only | The number of packets received that are dropped by the Router Control processor. |
| C32 cadSysProcArpPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.4 | Counter32 | read-only | The number of ARP packets received passed to the processor. |
| C32 cadSysProcArpPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.5 | Counter32 | read-only | The number of ARP packets received that are dropped. |
| C32 cadSysProcDhcpPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.7 | Counter32 | read-only | The number of DHCP packets received passed to the processor. |
| C32 cadSysProcDhcpPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.8 | Counter32 | read-only | The number of DHCP packets received that are dropped. |
| C32 cadSysProcIcmpPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.10 | Counter32 | read-only | The number of ICMP packets received passed to the processor. |
| C32 cadSysProcIcmpPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.11 | Counter32 | read-only | The number of ICMP packets received that are dropped. |
| C32 cadSysProcOspfPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.13 | Counter32 | read-only | The number of OSPFv2 packets received passed to the processor. |
| C32 cadSysProcOspfPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.14 | Counter32 | read-only | The number of OSPFv2 packets received that are dropped. |
| C32 cadSysProcRipPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.16 | Counter32 | read-only | The number of RIP packets received passed to the processor. |
| C32 cadSysProcRipPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.17 | Counter32 | read-only | The number of RIP packets received that are dropped. |
| C32 cadSysProcIgmpPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.19 | Counter32 | read-only | The number of IGMP packets received passed to the processor. |
| C32 cadSysProcIgmpPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.20 | Counter32 | read-only | The number of IGMP packets received that are dropped. |
| C32 cadSysProcRouterControlOtherPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.22 | Counter32 | read-only | The number of other packets received passed to the Router Control processor. |
| C32 cadSysProcRouterControlOtherPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.23 | Counter32 | read-only | The number of other packets received that are dropped by the Router Control processor. |
| C32 cadSysProcSnmpPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.25 | Counter32 | read-only | The number of SNMP packets received passed to the System Control processor. |
| C32 cadSysProcSnmpPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.26 | Counter32 | read-only | The number of SNMP packets received that are dropped. |
| C32 cadSysProcTftpPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.28 | Counter32 | read-only | The number of TFTP packets received passed to the processor. |
| C32 cadSysProcTftpPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.29 | Counter32 | read-only | The number of TFTP packets received that are dropped. |
| C32 cadSysProcIsisPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.31 | Counter32 | read-only | The number of IS-IS packets received passed to the processor. |
| C32 cadSysProcIsisPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.32 | Counter32 | read-only | The number of IS-IS packets received that are dropped. |
| C32 cadSysProcNdPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.37 | Counter32 | read-only | The number of Neighbor Discover packets received passed to the processor. |
| C32 cadSysProcNdPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.38 | Counter32 | read-only | The number of Neighbor Discover packets received that are dropped. |
| C32 cadSysProcDhcpIpv6PacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.40 | Counter32 | read-only | The number of DHCP(Ipv6) packets received passed to the processor. |
| C32 cadSysProcDhcpIpv6PacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.41 | Counter32 | read-only | The number of DHCP(IPv6) packets received that are dropped. |
| C32 cadSysProcIcmpIpv6PacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.43 | Counter32 | read-only | The number of ICMP(Ipv6) packets received passed to the processor. |
| C32 cadSysProcIcmpIpv6PacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.44 | Counter32 | read-only | The number of ICMP(IPv6) packets received that are dropped. |
| C32 cadSysProcMldPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.46 | Counter32 | read-only | The number of MLD packets received passed to the processor. |
| C32 cadSysProcMldPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.47 | Counter32 | read-only | The number of MLD packets received that are dropped. |
| C32 cadSysProcBgpPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.49 | Counter32 | read-only | The number of BGP packets received passed to the processor. |
| C32 cadSysProcBgpPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.50 | Counter32 | read-only | The number of BGP packets received that are dropped. |
| C32 cadSysProcPimPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.52 | Counter32 | read-only | The number of PIM packets received passed to the processor. |
| C32 cadSysProcPimPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.53 | Counter32 | read-only | The number of PIM packets received that are dropped. |
| C32 cadSysProcSnmpCmPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.55 | Counter32 | read-only | The number of SNMP (from CMs) packets received passed to the processor. |
| C32 cadSysProcSnmpCmPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.56 | Counter32 | read-only | The number of SNMP (from CMs) packets received that are dropped. |
| C32 cadSysProcCopsPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.58 | Counter32 | read-only | The number of COPS packets received passed to the System Control processor. |
| C32 cadSysProcCopsPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.59 | Counter32 | read-only | The number of COPS packets received that are dropped. |
| C32 cadSysProcTelnetPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.61 | Counter32 | read-only | The number of TELNET packets received passed to the System Control processor. |
| C32 cadSysProcTelnetPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.62 | Counter32 | read-only | The number of TELNET packets received that are dropped. |
| C32 cadSysProcOspfv3PacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.64 | Counter32 | read-only | The number of OSPFv3 packets received passed to the processor. |
| C32 cadSysProcOspfv3PacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.65 | Counter32 | read-only | The number of OSPFv3 packets received that are dropped. |
| C32 cadSysProcTftpIpv6PacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.67 | Counter32 | read-only | The number of TFTP (IPv6) packets received passed to the processor. |
| C32 cadSysProcTftpIpv6PacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.68 | Counter32 | read-only | The number of TFTP (IPv6) packets received that are dropped. |
| C32 cadSysProcLdpPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.70 | Counter32 | read-only | The number of LDP (UDP and TCP) packets received passed to the processor. |
| C32 cadSysProcLdpPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.71 | Counter32 | read-only | The number of LDP (UDP and TCP) packets received that are dropped. |
| C32 cadSysProcEventIcmpPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.73 | Counter32 | read-only | The number of ICMP event packets received passed to the processor. |
| C32 cadSysProcEventIcmpPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.74 | Counter32 | read-only | The number of ICMP event packets received that are dropped. |
| C32 cadSysProcEventNoRoutePacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.75 | Counter32 | read-only | The number of No Route event packets received passed to the processor. |
| C32 cadSysProcEventNoRoutePacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.76 | Counter32 | read-only | The number of No Route event packets received that are dropped. |
| C32 cadSysProcEventIcmpIpv6PacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.77 | Counter32 | read-only | The number of ICMP (IPv6) event packets received passed to the processor. |
| C32 cadSysProcEventIcmpIpv6PacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.78 | Counter32 | read-only | The number of ICMP (IPv6) event packets received that are dropped. |
| C32 cadSysProcEventNoRouteIpv6PacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.79 | Counter32 | read-only | The number of No Route (IPv6) event packets received passed to the processor. |
| C32 cadSysProcEventNoRouteIpv6PacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.80 | Counter32 | read-only | The number of No Route (IPv6) event packets received that are dropped. |
| C32 cadSysProcEventArpPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.81 | Counter32 | read-only | The number of ARP event packets received passed to the processor. |
| C32 cadSysProcEventArpPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.82 | Counter32 | read-only | The number of ARP event packets received that are dropped. |
| C32 cadSysProcEventNdPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.83 | Counter32 | read-only | The number of ND event packets received passed to the processor. |
| C32 cadSysProcEventNdPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.84 | Counter32 | read-only | The number of ND event packets received that are dropped. |
| C32 cadSysProcEventTtlPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.85 | Counter32 | read-only | The number of TTL event packets received passed to the processor. |
| C32 cadSysProcEventTtlPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.86 | Counter32 | read-only | The number of TTL event packets received that are dropped. |
| C32 cadSysProcEventTtlIpv6PacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.87 | Counter32 | read-only | The number of TTL (IPv6) event packets received passed to the processor. |
| C32 cadSysProcEventTtlIpv6PacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.88 | Counter32 | read-only | The number of TTL (IPv6) event packets received that are dropped. |
| C32 cadSysProcEventDadPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.89 | Counter32 | read-only | The number of DAD event packets received passed to the processor. |
| C32 cadSysProcEventDadPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.90 | Counter32 | read-only | The number of DAD event packets received that are dropped. |
| C32 cadSysProcEventDefaultPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.91 | Counter32 | read-only | The number of Default event packets received passed to the processor. |
| C32 cadSysProcEventDefaultPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.92 | Counter32 | read-only | The number of Default event packets received that are dropped. |
| C32 cadSysProcLacpPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.93 | Counter32 | read-only | The number of LACP packets received passed to the processor. |
| C32 cadSysProcLacpPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.94 | Counter32 | read-only | The number of LACP packets received that are dropped. |
| C32 cadSysProcVrepPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.95 | Counter32 | read-only | The number of D6/VREP packets received passed to the processor. |
| C32 cadSysProcVrepPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.96 | Counter32 | read-only | The number of D6/VREP packets received that are dropped. |
| C32 cadSysProcVpmePacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.97 | Counter32 | read-only | The number of VPME packets received passed to the processor. |
| C32 cadSysProcVpmePacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.98 | Counter32 | read-only | The number of VPME packets received that are dropped. |
| C32 cadSysProcErmRpcPacketsReceivedPassed | 1.3.6.1.4.1.4998.1.1.5.1.14.99 | Counter32 | read-only | The number of ERM RPC packets received passed to the processor. |
| C32 cadSysProcErmRpcPacketsReceivedDropped | 1.3.6.1.4.1.4998.1.1.5.1.14.100 | Counter32 | read-only | The number of ERM RPC packets received that are dropped. |
| cadSysBanner | 1.3.6.1.4.1.4998.1.1.5.1.15 | |||
| cadSysBannerMotdTable | 1.3.6.1.4.1.4998.1.1.5.1.15.1 | not-accessible | Table describing the MOTD banner that is displayed before the login: prompt | |
| cadSysBannerMotdEntry | 1.3.6.1.4.1.4998.1.1.5.1.15.1.1 | not-accessible | Describes a line in the MOTD banner | |
| I32 cadSysBannerMotdLine | 1.3.6.1.4.1.4998.1.1.5.1.15.1.1.1 | Integer32 | not-accessible | The line number |
| STR cadSysBannerMotdText | 1.3.6.1.4.1.4998.1.1.5.1.15.1.1.2 | DisplayString | read-create | The MOTD banner text |
| ROW cadSysBannerMotdRowStatus | 1.3.6.1.4.1.4998.1.1.5.1.15.1.1.3 | RowStatus | read-create | The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted. |
| cadSysBannerLoginTable | 1.3.6.1.4.1.4998.1.1.5.1.15.2 | not-accessible | Table describing the login banner that is displayed after the MOTD banner and before the login: prompt | |
| cadSysBannerLoginEntry | 1.3.6.1.4.1.4998.1.1.5.1.15.2.1 | not-accessible | Describes a line in the login banner | |
| I32 cadSysBannerLoginLine | 1.3.6.1.4.1.4998.1.1.5.1.15.2.1.1 | Integer32 | not-accessible | The line number |
| STR cadSysBannerLoginText | 1.3.6.1.4.1.4998.1.1.5.1.15.2.1.2 | DisplayString | read-create | The login banner text |
| ROW cadSysBannerLoginRowStatus | 1.3.6.1.4.1.4998.1.1.5.1.15.2.1.3 | RowStatus | read-create | The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted. |
| cadSysBannerExecTable | 1.3.6.1.4.1.4998.1.1.5.1.15.3 | not-accessible | ||
| cadSysBannerExecEntry | 1.3.6.1.4.1.4998.1.1.5.1.15.3.1 | not-accessible | ||
| I32 cadSysBannerExecLine | 1.3.6.1.4.1.4998.1.1.5.1.15.3.1.1 | Integer32 | not-accessible | Index of this banner line. |
| STR cadSysBannerExecText | 1.3.6.1.4.1.4998.1.1.5.1.15.3.1.2 | DisplayString | read-create | Ascii text of this banner line. |
| ROW cadSysBannerExecRowStatus | 1.3.6.1.4.1.4998.1.1.5.1.15.3.1.3 | RowStatus | read-create | The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted. |
| cadSysBannerIncomingTable | 1.3.6.1.4.1.4998.1.1.5.1.15.4 | not-accessible | ||
| cadSysBannerIncomingEntry | 1.3.6.1.4.1.4998.1.1.5.1.15.4.1 | not-accessible | ||
| I32 cadSysBannerIncomingLine | 1.3.6.1.4.1.4998.1.1.5.1.15.4.1.1 | Integer32 | not-accessible | |
| STR cadSysBannerIncomingText | 1.3.6.1.4.1.4998.1.1.5.1.15.4.1.2 | DisplayString | read-create | |
| ROW cadSysBannerIncomingRowStatus | 1.3.6.1.4.1.4998.1.1.5.1.15.4.1.3 | RowStatus | read-create | The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted. |
| cadSysServer | 1.3.6.1.4.1.4998.1.1.5.1.16 | |||
| cadSysServerTable | 1.3.6.1.4.1.4998.1.1.5.1.16.1 | not-accessible | Table describing the (INET) services that should run on the SCM. | |
| cadSysServerEntry | 1.3.6.1.4.1.4998.1.1.5.1.16.1.1 | not-accessible | Describes an INET service and whether it is enabled | |
| SER cadSysServerType | 1.3.6.1.4.1.4998.1.1.5.1.16.1.1.1 | ServerType | not-accessible | The service type |
| ADM cadSysServerAdminState | 1.3.6.1.4.1.4998.1.1.5.1.16.1.1.2 | AdminState | read-create | The administrative state of the server. |
| cadSysPatchParams | 1.3.6.1.4.1.4998.1.1.5.1.17 | |||
| cadSysPatchParamTable | 1.3.6.1.4.1.4998.1.1.5.1.17.1 | not-accessible | Table of patch parameters. | |
| cadSysPatchParamEntry | 1.3.6.1.4.1.4998.1.1.5.1.17.1.1 | not-accessible | Entry of an individual patch parameter. | |
| I32 cadSysPatchParamIndex | 1.3.6.1.4.1.4998.1.1.5.1.17.1.1.1 | Integer32 | not-accessible | The patch parameter index. |
| STR cadSysPatchParamName | 1.3.6.1.4.1.4998.1.1.5.1.17.1.1.2 | DisplayString | read-create | The patch parameter name. |
| STR cadSysPatchParamValue | 1.3.6.1.4.1.4998.1.1.5.1.17.1.1.3 | DisplayString | read-create | The patch parameter value. |
| STR cadSysPatchParamDescription | 1.3.6.1.4.1.4998.1.1.5.1.17.1.1.4 | DisplayString | read-create | The patch parameter description. |
| ROW cadSysPatchParamRowStatus | 1.3.6.1.4.1.4998.1.1.5.1.17.1.1.5 | RowStatus | read-create | The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted. |
| cadSysMtceParams | 1.3.6.1.4.1.4998.1.1.5.1.19 | |||
| U32 cadSysMtceStatusCloneMonitorThreshold | 1.3.6.1.4.1.4998.1.1.5.1.19.8 | Unsigned32 | read-write | Timeout during normal operation. |
| U32 cadSysMtceStatusCloneInitThreshold | 1.3.6.1.4.1.4998.1.1.5.1.19.9 | Unsigned32 | read-write | Timeout on initialization for first status message. |
| U32 cadSysMtceStatusCloneRcvyThreshold | 1.3.6.1.4.1.4998.1.1.5.1.19.10 | Unsigned32 | read-write | Timeout following clone side recovery. |
| U32 cadSysMtceBasePingRate | 1.3.6.1.4.1.4998.1.1.5.1.19.11 | Unsigned32 | read-write | Interval between system maintenance polling of monitored threads. |
| OVE cadSysMtceOvSensitivity | 1.3.6.1.4.1.4998.1.1.5.1.19.12 | OverloadThreshold | read-write | Defines the sensitivity of user overload to changes in internal work load. Higher sensitivity results in more rapid change of user overload in response to a change in the internal work load. |
| OVE cadSysMtceOvThreshold | 1.3.6.1.4.1.4998.1.1.5.1.19.13 | OverloadThreshold | read-write | Defines the overall threshold of user overload transitions. Higher thresholds require a longer time in an internal overload state before user overload transitions occur. |
| U32 cadSysMtceDULPacketInterval | 1.3.6.1.4.1.4998.1.1.5.1.19.14 | Unsigned32 | read-write | Interval between maintenance polling of monitored BroadCom devices. Setting the value to zero will disable BroadCom device monitoring. |
| cadSysDataServer | 1.3.6.1.4.1.4998.1.1.5.1.21 | |||
| U32 cadSysDataServerDataTimeout | 1.3.6.1.4.1.4998.1.1.5.1.21.1 | Unsigned32 | read-write | Time allowed for Data Query/Update to be processed. |
| U32 cadSysDataServerDataEventsPerCycle | 1.3.6.1.4.1.4998.1.1.5.1.21.2 | Unsigned32 | read-write | Number of data events allowed per cycle. |
| U32 cadSysDataServerDataSyncTimeout | 1.3.6.1.4.1.4998.1.1.5.1.21.3 | Unsigned32 | read-write | Number of data events allowed per cycle. |
| T/F cadSysDataServerSnmpReadAheadEnable | 1.3.6.1.4.1.4998.1.1.5.1.21.4 | TruthValue | read-write | When this value is set to true Snmp read ahead is performed. |
| U32 cadSysDataServerSnmpReadAheadMax | 1.3.6.1.4.1.4998.1.1.5.1.21.5 | Unsigned32 | read-write | This value is the maximum number of records to read ahead |
| U32 cadSysDataServerSnmpRefreshTime | 1.3.6.1.4.1.4998.1.1.5.1.21.6 | Unsigned32 | read-write | This value represents how old a database record can be to be used. |
| U32 cadSysDataServerSyncDataEventsPerCycle | 1.3.6.1.4.1.4998.1.1.5.1.21.7 | Unsigned32 | read-write | This value is the maximum number of Sync events that will be processed per cycle. |
| U32 cadSysDataServerLoPriDataEventsPerCycle | 1.3.6.1.4.1.4998.1.1.5.1.21.8 | Unsigned32 | read-write | This value is the maximum number of Low Priority Sync events to be processed per cycle. |
| cadSysSourceAddress | 1.3.6.1.4.1.4998.1.1.5.1.22 | |||
| cadSysSourceAddressTable | 1.3.6.1.4.1.4998.1.1.5.1.22.1 | not-accessible | Table of source interface addresses for administrative services | |
| cadSysSourceAddressEntry | 1.3.6.1.4.1.4998.1.1.5.1.22.1.1 | not-accessible | This entry contains the configured source IPv4 and/or IPv6 address for each administrative service. If configured, it also contains the global default address. | |
| ADM cadSysSourceAddressIndex | 1.3.6.1.4.1.4998.1.1.5.1.22.1.1.1 | AdminSrcAddrType | not-accessible | The type of administrative service. |
| NUM cadSysSourceInterfaceIpv4IfIndex | 1.3.6.1.4.1.4998.1.1.5.1.22.1.1.2 | InterfaceIndexOrZero | read-write | The ifIndex of the interface from which all IPv4 packets are sourced. For a server service, it is also the only DIP allowed for incoming requests. A value of 0 indicates no source interface override. |
| ADR cadSysSourceAddressIpv4Address | 1.3.6.1.4.1.4998.1.1.5.1.22.1.1.3 | InetAddressIPv4 | read-only | The IPv4 address of the IPv4 interface at the time the row ipv4 ifIndex was populated. Used as the source address for the service if the state is in-service. For a server service, it is also the only DIP allowed for incoming requests. A value of null indicates no source address has been assigned. |
| NUM cadSysSourceInterfaceIpv6IfIndex | 1.3.6.1.4.1.4998.1.1.5.1.22.1.1.4 | InterfaceIndexOrZero | read-write | The ifIndex of the interface from which all IPv6 packets are sourced (not currently supported). For a server service, it is also the only DIP allowed for incoming requests. A value of 0 indicates no source interface override. |
| ADR cadSysSourceAddressIpv6Address | 1.3.6.1.4.1.4998.1.1.5.1.22.1.1.5 | InetAddressIPv6 | read-only | The IPv6 address of the IPv6 interface at the time the ipv6 ifIndex was populated. Used as the source address for the service if the state is in-service. For a server service, it is also the only DIP allowed for incoming requests. A value of null indicates no source address has been assigned. |
| cadSysLicenseControl | 1.3.6.1.4.1.4998.1.1.5.1.23 | |||
| CAR cadSysLicenseCardId | 1.3.6.1.4.1.4998.1.1.5.1.23.1 | CardId | not-accessible | CAM to be licensed. |
| OCT cadSysLicenseKey | 1.3.6.1.4.1.4998.1.1.5.1.23.2 | OCTET STRING | not-accessible | License key to apply to the CAM. |
| I32 cadSysLicensePorts | 1.3.6.1.4.1.4998.1.1.5.1.23.3 | Integer32 | not-accessible | Number of CAM ports associated with the license. |
| INT cadSysLicenseAnnex | 1.3.6.1.4.1.4998.1.1.5.1.23.4 | INTEGER | not-accessible | This attribute defines the ITU-J-83 Annex being used for this E6000 CMTS License. |
| INT cadSysLicenseStatus | 1.3.6.1.4.1.4998.1.1.5.1.23.5 | INTEGER | read-only | Current status of licensing operation. |
| cadLaesMdTimestampMode | 1.3.6.1.4.1.4998.1.1.5.1.24 | |||
| cadLaesMdTimestampModeTable | 1.3.6.1.4.1.4998.1.1.5.1.24.1 | not-accessible | Table of LAES Mediation Device Timestamp mode table | |
| cadLaesMdTimestampModeEntry | 1.3.6.1.4.1.4998.1.1.5.1.24.1.1 | not-accessible | This entry contains the configured MD IPv4. If configured, then all encapsulated tap packets going to that MD will contain a timestamp in the tap header. | |
| IPt cadLaesMdTimestampModeInetAddrType | 1.3.6.1.4.1.4998.1.1.5.1.24.1.1.1 | InetAddressType | not-accessible | The IP Address type of Mediation Device |
| IP cadLaesMdTimestampModeInetAddr | 1.3.6.1.4.1.4998.1.1.5.1.24.1.1.2 | InetAddress | not-accessible | The IP Address of the Mediation Device. |
| ROW cadLaesMdTimestampModRowStatus | 1.3.6.1.4.1.4998.1.1.5.1.24.1.1.3 | RowStatus | read-create | The row status of this entry |
| cadSysSharedSecret | 1.3.6.1.4.1.4998.1.1.5.1.25 | |||
| cadSysMICSecondarySecretTable | 1.3.6.1.4.1.4998.1.1.5.1.25.1 | not-accessible | Table containing secondary shared secret strings for cable modem configuration file authentication. This table is not used unless cadSysMICEnable is set to true. | |
| cadSysMICSecondarySecretEntry | 1.3.6.1.4.1.4998.1.1.5.1.25.1.1 | not-accessible | Entry containing secondary shared secret strings for cable modem configuration file authentication. | |
| INT cadSysMICSecondarySecretIndex | 1.3.6.1.4.1.4998.1.1.5.1.25.1.1.1 | INTEGER | not-accessible | Internal index for this MIB row. |
| OCT cadSysMICSecondarySecretString | 1.3.6.1.4.1.4998.1.1.5.1.25.1.1.2 | OCTET STRING | read-create | Encrypted MIC Authentication shared secret string. |
| ROW cadSysMICSecondarySecretStatus | 1.3.6.1.4.1.4998.1.1.5.1.25.1.1.3 | RowStatus | read-create | The status of this conceptual row. |
RFC description
ARRIS (formerly Cadant) vendor-private MIB for CMTS system parameters, constants, and overall E6000 platform management.
Start monitoring ARRIS E6000 CMTS with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.