CADANT-CMTS-SYSTEM-MIB :: cadSysT5Timeout

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCADANT-CMTS-SYSTEM-MIBcadSysT5Timeout

cadSysT5Timeout

Module: CADANT-CMTS-SYSTEM-MIB

OID (symbolic): CADANT-CMTS-SYSTEM-MIB::cadSysT5Timeout

OID (numeric): 1.3.6.1.4.1.4998.1.1.5.1.1.10

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Wait for Upstream CHannel Change response.

What is cadSysT5Timeout?

Reports the T5 timer value, which is the time the CMTS waits for a response to an Upstream Channel Change (UCC) request sent to a cable modem. If no response arrives within this window, the channel change is considered to have failed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.5.1.1.10
snmpwalk -v2c -c public <target> CADANT-CMTS-SYSTEM-MIB::cadSysT5Timeout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.5.1.1.10.1
snmpget -v2c -c public <target> CADANT-CMTS-SYSTEM-MIB::cadSysT5Timeout.1

Start monitoring ARRIS E6000 CMTS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CADANT-CMTS-SYSTEM-MIB::cadSysT5Timeout OID value, configure state conditions and alerts, and monitor any ARRIS E6000 CMTS from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4998cadantCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1cadObjectsCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1cadCableCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1.5cadSystemCADANT-PRODUCTS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4998.1.1.5.1cadSystemMibCADANT-CMTS-SYSTEM-MIB
1.3.6.1.4.1.4998.1.1.5.1.1cadSysParamsCADANT-CMTS-SYSTEM-MIB
1.3.6.1.4.1.4998.1.1.5.1.1.10cadSysT5TimeoutCADANT-CMTS-SYSTEM-MIB