cadSysProcClearPolicingCounts

Module: CADANT-CMTS-SYSTEM-MIB

OID (symbolic): CADANT-CMTS-SYSTEM-MIB::cadSysProcClearPolicingCounts

OID (numeric): 1.3.6.1.4.1.4998.1.1.5.1.13.35

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: This variable always returns false(2) upon reading. When set to true(1), all objects under cadSysProcPolicingCounts are cleared.

What is cadSysProcClearPolicingCounts?

A write-only control object that resets all packet-policing counters under cadSysProcPolicingCounts when set to true. Reading it always returns false, making it a one-shot action trigger rather than a persistent setting.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.5.1.13.35
snmpwalk -v2c -c public <target> CADANT-CMTS-SYSTEM-MIB::cadSysProcClearPolicingCounts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.5.1.13.35.1
snmpget -v2c -c public <target> CADANT-CMTS-SYSTEM-MIB::cadSysProcClearPolicingCounts.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4998.1.1.5.1.13.35.1 s <value>

Start monitoring ARRIS E6000 CMTS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CADANT-CMTS-SYSTEM-MIB::cadSysProcClearPolicingCounts OID value, configure state conditions and alerts, and monitor any ARRIS E6000 CMTS from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4998cadantCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1cadObjectsCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1cadCableCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1.5cadSystemCADANT-PRODUCTS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4998.1.1.5.1cadSystemMibCADANT-CMTS-SYSTEM-MIB
1.3.6.1.4.1.4998.1.1.5.1.13cadSysProcPolicingConfigCADANT-CMTS-SYSTEM-MIB