All MIBs › CADANT-CMTS-SYSTEM-MIB › cadSysReloadOperation
cadSysReloadOperation
Module: CADANT-CMTS-SYSTEM-MIB
OID (symbolic): CADANT-CMTS-SYSTEM-MIB::cadSysReloadOperation
OID (numeric): 1.3.6.1.4.1.4998.1.1.5.1.6.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Control object for E6000 reload, reading this object always returns none(99)
What is cadSysReloadOperation?
Acts as a control object for triggering an E6000 chassis reload; writing a specific value initiates the reload operation while reading it always returns none(99) to indicate no active operation. This is used by management systems to programmatically restart the CMTS.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.5.1.6.1 snmpwalk -v2c -c public <target> CADANT-CMTS-SYSTEM-MIB::cadSysReloadOperation
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.5.1.6.1.1 snmpget -v2c -c public <target> CADANT-CMTS-SYSTEM-MIB::cadSysReloadOperation.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4998.1.1.5.1.6.1.1 i <value>
Start monitoring ARRIS E6000 CMTS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CADANT-CMTS-SYSTEM-MIB::cadSysReloadOperation OID value, configure state conditions and alerts, and monitor any ARRIS E6000 CMTS from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4998 | cadant | CADANT-PRODUCTS-MIB |
| 1.3.6.1.4.1.4998.1 | cadObjects | CADANT-PRODUCTS-MIB |
| 1.3.6.1.4.1.4998.1.1 | cadCable | CADANT-PRODUCTS-MIB |
| 1.3.6.1.4.1.4998.1.1.5 | cadSystem | CADANT-PRODUCTS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4998.1.1.5.1 | cadSystemMib | CADANT-CMTS-SYSTEM-MIB |
| 1.3.6.1.4.1.4998.1.1.5.1.6 | cadSysReload | CADANT-CMTS-SYSTEM-MIB |
| 1.3.6.1.4.1.4998.1.1.5.1.6.1 | cadSysReloadOperation | CADANT-CMTS-SYSTEM-MIB |