All MIBs › OMNI-gx2GS1000-MIB › gs1000valueFactoryDataCRC
gs1000valueFactoryDataCRC
Module: OMNI-gx2GS1000-MIB
OID (symbolic): OMNI-gx2GS1000-MIB::gs1000valueFactoryDataCRC
OID (numeric): 1.3.6.1.4.1.1166.6.1.2.36.4.3.9
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
What is gs1000valueFactoryDataCRC?
Reports the checksum status of the factory calibration data block, encoded as ok(1), undetermined(2), warning(3), minor(4), major(5) or critical(6). An admin watches this for anything other than ok/undetermined as a sign of trouble with the module's self-check for this subsystem. Note the DESCRIPTION text's parenthetical numbering ("0-Ok, 1-Undetermined...") is off by one versus the real SYNTAX enumeration used on the wire, which starts at ok(1).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.36.4.3.9 snmpwalk -v2c -c public <target> OMNI-gx2GS1000-MIB::gs1000valueFactoryDataCRC
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.36.4.3.9.1 snmpget -v2c -c public <target> OMNI-gx2GS1000-MIB::gs1000valueFactoryDataCRC.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> gs1000valueFactoryDataCRC.1
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 GS1000 gigabit Ethernet switch module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2GS1000-MIB::gs1000valueFactoryDataCRC OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 GS1000 gigabit Ethernet switch module) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1166 | gi | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6 | motproxies | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6.1 | hfc | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2 | hfcDevices | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2.36 | gx2Gs1000 | GX2HFC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.36.4 | gx2gs1000StatusTable | OMNI-gx2GS1000-MIB |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3 | gx2gs1000StatusEntry | OMNI-gx2GS1000-MIB |
| 1.3.6.1.4.1.1166.6.1.2.36.4.3.9 | gs1000valueFactoryDataCRC | OMNI-gx2GS1000-MIB |