All MIBs › OMNI-gx2EA1000-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 EA1000 Ethernet adapter module in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2EA1000-MIB?
This MIB manages the Cisco/Scientific-Atlanta GX2 EA1000 Ethernet adapter module, a component used in hybrid fiber-coax (HFC) optical node deployments within cable/broadband access networks to bridge Ethernet traffic at the node. No object list was captured for this module in the provided source, but as an OMNI-family GX2 module MIB it would be expected to expose module identity, port/link status, and basic operational alarms for the Ethernet adapter card. Its monitoring value centers on hardware/link status of the Ethernet adapter -- confirming the module is present, its Ethernet port is up, and no alarm conditions are asserted -- rather than exposing rich protocol counters. It is a vendor-specific module tied to the Cisco/Scientific-Atlanta OMNI optical node management architecture rather than IETF standards. It is deployed on Cisco/Scientific-Atlanta GX2 optical nodes in HFC cable network outside-plant deployments, as documented in the OMNI-gx2EA1000-MIB MIB.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2EA1000-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 EA1000 Ethernet adapter module)
Monitoring Examples
No sample objects were available for this MIB in the provided source, so specific object names cannot be cited; based on its stated purpose, an operator would typically poll module presence/identity and Ethernet link-status objects for the EA1000 adapter within the GX2 node's OMNI object tree. A module reporting absent or a port showing link-down status would indicate a failed or disconnected Ethernet adapter in the field node. This module is primarily a hardware-presence and link-status monitor for the Ethernet adapter card rather than a traffic-statistics MIB.
What Can Be Monitored
- module presence/identity
- Ethernet port link status
- module alarm/fault status
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Ea1000 | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapEA1000ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.33.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapEA1000ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.33.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapEA1000RFInputAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.3 | This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEA1000RFOverloadAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.4 | This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEA1000RFOffsetAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.5 | This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEA1000OpticalPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.6 | This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEA1000LaserBiasAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.7 | This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEA1000LaserTempAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.8 | This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEA1000TECCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.9 | This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEA1000Fan1SpeedAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.10 | This trap is issued when the Laser Modules Fan 1 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEA1000Fan2SpeedAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.11 | This trap is issued when the Laser Modules Fan 2 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEA100012vAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.12 | This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEA1000ModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.13 | This trap is issued when the Laser Module Temperature goes out of range. | ||
| NTF trapEA1000FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.14 | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| NTF trapEA1000LaserBiasCntLoopAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.15 | This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation. | ||
| NTF trapEA1000BankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.16 | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| NTF trapEA1000LaserBiasCntLoopInitAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.17 | This trap is issued when the Laser Bias Control loop init fails. | ||
| NTF trapEA1000RFParamInitAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.18 | This trap is issued when the RF parameter Init fails. | ||
| NTF trapEA1000TECParamInitAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.19 | This trap is issued when the TEC Parameter Init fails. | ||
| NTF trapEA1000AttnTableInitAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.20 | This trap is issued when the Attenuator Table Init fails. | ||
| NTF trapEA1000PowerMeterTableInitAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.21 | This trap is issued when the Power Meter Table Init fails. | ||
| NTF trapEA1000LaserDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.22 | This trap is issued when the Laser Data CRC is incorrect. | ||
| NTF trapEA1000AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.23 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapEA1000FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.24 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapEA1000UserRFOffAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.25 | This trap is issued when the the User RF is turned off. | ||
| NTF trapEA1000UserOpticalOffAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.26 | This trap is issued when the User Optical Power is turned off. | ||
| NTF trapEA1000ResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.33.0.27 | This trap is issued when the Factory Default Reset occurs. | ||
| gx2ea1000Descriptor | 1.3.6.1.4.1.1166.6.1.2.33.1 | |||
| gx2ea1000AnalogTable | 1.3.6.1.4.1.1166.6.1.2.33.2 | not-accessible | This table contains gx2Ea1000 specific parameters with nominal and current values. | |
| gx2ea1000AnalogEntry | 1.3.6.1.4.1.1166.6.1.2.33.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2ea1000AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.33.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR ea1000labelOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.33.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Offset Monitor Analog parameter. |
| STR ea1000uomOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.33.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. |
| FLO ea1000majorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.33.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000majorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.33.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000minorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.33.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO ea1000minorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.33.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO ea1000currentValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.33.2.1.8 | Float | read-only | The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| INT ea1000stateFlagOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.33.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO ea1000minValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.33.2.1.10 | Float | read-only | The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number. |
| FLO ea1000maxValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.33.2.1.11 | Float | read-only | The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number. |
| INT ea1000alarmStateOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.33.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Offset Monitor Analog parameter. |
| STR ea1000labelOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Offset Control Analog parameter. |
| STR ea1000uomOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.14 | DisplayString | read-only | The value of this object provides the label of the Offset Control Analog parameter. |
| FLO ea1000majorHighOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000majorLowOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000minorHighOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000minorLowOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000currentValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.19 | Float | read-write | The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000stateFlagOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO ea1000minValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.21 | Float | read-only | The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000maxValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.22 | Float | read-only | The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000alarmStateOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Offset Control Analog parameter. |
| STR ea1000labelOptPower | 1.3.6.1.4.1.1166.6.1.2.33.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR ea1000uomOptPower | 1.3.6.1.4.1.1166.6.1.2.33.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO ea1000majorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.33.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000majorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.33.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000minorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.33.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000minorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.33.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000currentValueOptPower | 1.3.6.1.4.1.1166.6.1.2.33.2.1.30 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000stateFlagOptPower | 1.3.6.1.4.1.1166.6.1.2.33.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO ea1000minValueOptPower | 1.3.6.1.4.1.1166.6.1.2.33.2.1.32 | Float | read-only | The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000maxValueOptPower | 1.3.6.1.4.1.1166.6.1.2.33.2.1.33 | Float | read-only | The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000alarmStateOptPower | 1.3.6.1.4.1.1166.6.1.2.33.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR ea1000labelLaserTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Laser Temperature Analog parameter. |
| STR ea1000uomLaserTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. |
| FLO ea1000majorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000majorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000minorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000minorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000currentValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.41 | Float | read-only | The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000stateFlagLaserTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO ea1000minValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.43 | Float | read-only | The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000maxValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.44 | Float | read-only | The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000alarmStateLaserTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. |
| STR ea1000labelLaserBias | 1.3.6.1.4.1.1166.6.1.2.33.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| STR ea1000uomLaserBias | 1.3.6.1.4.1.1166.6.1.2.33.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
| FLO ea1000majorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.33.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000majorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.33.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000minorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.33.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000minorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.33.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000currentValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.33.2.1.52 | Float | read-only | The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000stateFlagLaserBias | 1.3.6.1.4.1.1166.6.1.2.33.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO ea1000minValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.33.2.1.54 | Float | read-only | The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000maxValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.33.2.1.55 | Float | read-only | The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000alarmStateLaserBias | 1.3.6.1.4.1.1166.6.1.2.33.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Bias Analog parameter. |
| STR ea1000labelTecCurrent | 1.3.6.1.4.1.1166.6.1.2.33.2.1.57 | DisplayString | read-only | The value of this object provides the label of the TEC Current Analog parameter. |
| STR ea1000uomTecCurrent | 1.3.6.1.4.1.1166.6.1.2.33.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the TEC Current Analog parameter.. |
| FLO ea1000majorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.33.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000majorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.33.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000minorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.33.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000minorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.33.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000currentValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.33.2.1.63 | Float | read-only | The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000stateFlagTecCurrent | 1.3.6.1.4.1.1166.6.1.2.33.2.1.64 | INTEGER | read-only | The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO ea1000minValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.33.2.1.65 | Float | read-only | The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000maxValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.33.2.1.66 | Float | read-only | The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000alarmStateTecCurrent | 1.3.6.1.4.1.1166.6.1.2.33.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| STR ea1000labelModuleTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR ea1000uomModuleTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO ea1000majorHighModuleTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000majorLowModuleTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000minorHighModuleTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000minorLowModuleTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000currentValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.74 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000stateFlagModuleTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO ea1000minValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.76 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000maxValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.77 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000alarmStateModuleTemp | 1.3.6.1.4.1.1166.6.1.2.33.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR ea1000labelFan1Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.79 | DisplayString | read-only | The value of this object provides the label of the Fan 1 Speed Analog parameter. |
| STR ea1000uomFan1Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan 1 Speed Analog parameter. |
| FLO ea1000majorHighFan1Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000majorLowFan1Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000minorHighFan1Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000minorLowFan1Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000currentValueFan1Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.85 | Float | read-only | The value of this object provides the Current value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000stateFlagFan1Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.86 | INTEGER | read-only | The value of this object provides the state of the Fan 1 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO ea1000minValueFan1Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.87 | Float | read-only | The value of this object provides the minimum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000maxValueFan1Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.88 | Float | read-only | The value of this object provides the maximum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000alarmStateFan1Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan 1 Speed Analog parameter. |
| STR ea1000labelFan2Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.90 | DisplayString | read-only | The value of this object provides the label of the Fan 2 Speed Analog parameter. |
| STR ea1000uomFan2Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.91 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan 2 Speed Analog parameter. |
| FLO ea1000majorHighFan2Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.92 | Float | read-only | The value of this object provides the Major High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000majorLowFan2Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.93 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000minorHighFan2Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.94 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO ea1000minorLowFan2Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.95 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000currentValueFan2Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.96 | Float | read-only | The value of this object provides the Current value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000stateFlagFan2Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.97 | INTEGER | read-only | The value of this object provides the state of the Fan 2 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO ea1000minValueFan2Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.98 | Float | read-only | The value of this object provides the minimum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000maxValueFan2Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.99 | Float | read-only | The value of this object provides the maximum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000alarmStateFan2Speed | 1.3.6.1.4.1.1166.6.1.2.33.2.1.100 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan 2 Speed Analog parameter. |
| STR ea1000label12Volt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.101 | DisplayString | read-only | The value of this object provides the label of the 12v Current Analog parameter. |
| STR ea1000uom12Volt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.102 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO ea1000majorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.103 | Float | read-only | The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000majorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.104 | Float | read-only | The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000minorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.105 | Float | read-only | The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000minorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.106 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000currentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.107 | Float | read-only | The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000stateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.108 | INTEGER | read-only | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO ea1000minValue12Volt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.109 | Float | read-only | The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO ea1000maxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.110 | Float | read-only | The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT ea1000alarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.33.2.1.111 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| gx2ea1000DigitalTable | 1.3.6.1.4.1.1166.6.1.2.33.3 | not-accessible | This table contains gx2Ea1000 specific parameters with nominal and current values. | |
| gx2ea1000DigitalEntry | 1.3.6.1.4.1.1166.6.1.2.33.3.2 | not-accessible | This list contains digital parameters and descriptions. | |
| INT gx2ea1000DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.33.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR ea1000labelRfInput | 1.3.6.1.4.1.1166.6.1.2.33.3.2.2 | DisplayString | read-only | The value of this object provides the label of the RF Input Control Digital parameter. |
| STR ea1000enumRfInput | 1.3.6.1.4.1.1166.6.1.2.33.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT ea1000valueRfInput | 1.3.6.1.4.1.1166.6.1.2.33.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT ea1000stateflagRfInput | 1.3.6.1.4.1.1166.6.1.2.33.3.2.5 | INTEGER | read-only | The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ea1000labelOptOutput | 1.3.6.1.4.1.1166.6.1.2.33.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Optical Output Control Digital parameter. |
| STR ea1000enumOptOutput | 1.3.6.1.4.1.1166.6.1.2.33.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT ea1000valueOptOutput | 1.3.6.1.4.1.1166.6.1.2.33.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT ea1000stateflagOptOutput | 1.3.6.1.4.1.1166.6.1.2.33.3.2.9 | INTEGER | read-only | The value of this object provides the ea1000state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ea1000labelLaserMode | 1.3.6.1.4.1.1166.6.1.2.33.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Laser Mode Digital parameter. |
| STR ea1000enumLaserMode | 1.3.6.1.4.1.1166.6.1.2.33.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT ea1000valueLaserMode | 1.3.6.1.4.1.1166.6.1.2.33.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT ea1000stateflagLaserMode | 1.3.6.1.4.1.1166.6.1.2.33.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ea1000labelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.33.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Attenuation Setting Ditital Parameter. |
| STR ea1000enumAttenSetting | 1.3.6.1.4.1.1166.6.1.2.33.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT ea1000valueAttenSetting | 1.3.6.1.4.1.1166.6.1.2.33.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT ea1000stateflagAttenSetting | 1.3.6.1.4.1.1166.6.1.2.33.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ea1000labelLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.33.3.2.18 | DisplayString | read-only | The value of this object provides the label of the Laser Secondary Mode Digital parameter. |
| STR ea1000enumLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.33.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT ea1000valueLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.33.3.2.20 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT ea1000stateflagLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.33.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ea1000labelVideoOffset | 1.3.6.1.4.1.1166.6.1.2.33.3.2.22 | DisplayString | read-only | The value of this object provides the label of the Video Offset Digital parameter. |
| STR ea1000enumVideoOffset | 1.3.6.1.4.1.1166.6.1.2.33.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.. |
| INT ea1000valueVideoOffset | 1.3.6.1.4.1.1166.6.1.2.33.3.2.24 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT ea1000stateflagVideoOffset | 1.3.6.1.4.1.1166.6.1.2.33.3.2.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ea1000labelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.33.3.2.26 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR ea1000enumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.33.3.2.27 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT ea1000valueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.33.3.2.28 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT ea1000stateflagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.33.3.2.29 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2ea1000StatusTable | 1.3.6.1.4.1.1166.6.1.2.33.4 | not-accessible | This table contains gx2Ea1000 specific parameters with nominal and current values. | |
| gx2ea1000StatusEntry | 1.3.6.1.4.1.1166.6.1.2.33.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2ea1000StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.33.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR ea1000labelBoot | 1.3.6.1.4.1.1166.6.1.2.33.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT ea1000valueBoot | 1.3.6.1.4.1.1166.6.1.2.33.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT ea1000stateflagBoot | 1.3.6.1.4.1.1166.6.1.2.33.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ea1000labelFlash | 1.3.6.1.4.1.1166.6.1.2.33.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT ea1000valueFlash | 1.3.6.1.4.1.1166.6.1.2.33.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT ea1000stateflagFlash | 1.3.6.1.4.1.1166.6.1.2.33.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ea1000labelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.33.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT ea1000valueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.33.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT ea1000stateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.33.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ea1000labelLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.33.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Laser Data CRC Status parameter. |
| INT ea1000valueLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.33.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT ea1000stateflagLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.33.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ea1000labelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.33.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT ea1000valueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.33.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT ea1000stateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.33.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ea1000labelRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.33.4.3.17 | DisplayString | read-only | The value of this object provides the label of the RF Input Status parameter. |
| INT ea1000valueRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.33.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT ea1000stateflagRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.33.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2ea1000FactoryTable | 1.3.6.1.4.1.1166.6.1.2.33.5 | not-accessible | This table contains gx2Ea1000 specific parameters with nominal and current values. | |
| gx2ea1000FactoryEntry | 1.3.6.1.4.1.1166.6.1.2.33.5.4 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2ea1000FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.33.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT ea1000bootControlByteValue | 1.3.6.1.4.1.1166.6.1.2.33.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT ea1000bootStatusByteValue | 1.3.6.1.4.1.1166.6.1.2.33.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT ea1000bank1CRCValue | 1.3.6.1.4.1.1166.6.1.2.33.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT ea1000bank2CRCValue | 1.3.6.1.4.1.1166.6.1.2.33.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT ea1000prgEEPROMByteValue | 1.3.6.1.4.1.1166.6.1.2.33.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT ea1000factoryCRCValue | 1.3.6.1.4.1.1166.6.1.2.33.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT ea1000calculateCRCValue | 1.3.6.1.4.1.1166.6.1.2.33.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT ea1000hourMeterValue | 1.3.6.1.4.1.1166.6.1.2.33.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT ea1000flashPrgCntAValue | 1.3.6.1.4.1.1166.6.1.2.33.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT ea1000flashPrgCntBValue | 1.3.6.1.4.1.1166.6.1.2.33.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR ea1000flashBankARevValue | 1.3.6.1.4.1.1166.6.1.2.33.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR ea1000flashBankBRevValue | 1.3.6.1.4.1.1166.6.1.2.33.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
RFC description
Management information base for Omni gx2EA1000 laser module (1550nM forward path transmitter) in HFC networks. Includes device descriptor parameters and network element configuration.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EA1000 Ethernet adapter module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.