OMNI-gx2GS1000-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2Gs1000 FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "0" January 10, 2012 --DESCRIPTION -- Added revision and description comment section -- OMNISTAR GS1000 Laser Module (1550nM Forward Path Transmetter) MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2Gs1000E Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Gs1000E device type. -- These parameters are common across all network elements -- from gx2Gs1000 device type. -- -- The gx2Gs1000 Network Elements subgroup is -- a list of gx2Gs1000 type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Gs1000TableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2Gs1000 type. -- -- Both groups are mandatory for management of gx2Gs1000 devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. The Floating point number 10,000,000 will -- be used as an out of range or un-used limit indicator. It will be in the -- 32 bit hex representation of the IEE number as follows: 0x501502F9 Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2Gs1000 Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Gs1000 device type. -- These parameters are common across all network elements -- from gx2Gs1000 device type. gx2gs1000Descriptor OBJECT IDENTIFIER ::= {gx2Gs1000 1} --***************************************************************************** -- gx2Gs1000 Table -- Contains a list of all gx2Gs1000 type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2gs1000TableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2Gs1000 type. gx2gs1000AnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2gs1000AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Gs1000 specific parameters with nominal and current values." ::= { gx2Gs1000 2 } gx2gs1000AnalogEntry OBJECT-TYPE SYNTAX Gx2gs1000AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains the analog parameters and descriptions." INDEX { gx2gs1000AnalogTableIndex } ::= { gx2gs1000AnalogTable 1} --*********************************************************************** gx2gs1000DigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2gs1000DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Gs1000 specific parameters with nominal and current values." ::= { gx2Gs1000 3 } gx2gs1000DigitalEntry OBJECT-TYPE SYNTAX Gx2gs1000DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital parameters and descriptions." INDEX { gx2gs1000DigitalTableIndex } ::= { gx2gs1000DigitalTable 2} --*********************************************************************** gx2gs1000StatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2gs1000StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Gs1000 specific parameters with nominal and current values." ::= { gx2Gs1000 4 } gx2gs1000StatusEntry OBJECT-TYPE SYNTAX Gx2gs1000StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Status parameters and descriptions." INDEX { gx2gs1000StatusTableIndex } ::= { gx2gs1000StatusTable 3} --*********************************************************************** gx2gs1000FactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2gs1000FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Gs1000 specific parameters with nominal and current values." ::= { gx2Gs1000 5 } gx2gs1000FactoryEntry OBJECT-TYPE SYNTAX Gx2gs1000FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Factory parameters and descriptions." INDEX { gx2gs1000FactoryTableIndex } ::= { gx2gs1000FactoryTable 4} -- **************** Analog Parameters *********************** Gx2gs1000AnalogEntry ::= SEQUENCE { gx2gs1000AnalogTableIndex INTEGER, gs1000labelOffsetNomMonitor DisplayString (SIZE (0..80)), gs1000uomOffsetNomMonitor DisplayString (SIZE (0..80)), gs1000majorHighOffsetNomMonitor Float, gs1000majorLowOffsetNomMonitor Float, gs1000minorHighOffsetNomMonitor Float, gs1000minorLowOffsetNomMonitor Float, gs1000currentValueOffsetNomMonitor Float, gs1000stateFlagOffsetNomMonitor INTEGER, gs1000minValueOffsetNomMonitor Float, gs1000maxValueOffsetNomMonitor Float, gs1000alarmStateOffsetNomMonitor INTEGER, gs1000labelOffsetNomCnt DisplayString (SIZE (0..80)), gs1000uomOffsetNomCnt DisplayString (SIZE (0..80)), gs1000majorHighOffsetNomCnt Float, gs1000majorLowOffsetNomCnt Float, gs1000minorHighOffsetNomCnt Float, gs1000minorLowOffsetNomCnt Float, gs1000currentValueOffsetNomCnt Float, gs1000stateFlagOffsetNomCnt INTEGER, gs1000minValueOffsetNomCnt Float, gs1000maxValueOffsetNomCnt Float, gs1000alarmStateOffsetNomCnt INTEGER, gs1000labelOptPower DisplayString (SIZE (0..80)), gs1000uomOptPower DisplayString (SIZE (0..80)), gs1000majorHighOptPower Float, gs1000majorLowOptPower Float, gs1000minorHighOptPower Float, gs1000minorLowOptPower Float, gs1000currentValueOptPower Float, gs1000stateFlagOptPower INTEGER, gs1000minValueOptPower Float, gs1000maxValueOptPower Float, gs1000alarmStateOptPower INTEGER, gs1000labelLaserTemp DisplayString (SIZE (0..80)), gs1000uomLaserTemp DisplayString (SIZE (0..80)), gs1000majorHighLaserTemp Float, gs1000majorLowLaserTemp Float, gs1000minorHighLaserTemp Float, gs1000minorLowLaserTemp Float, gs1000currentValueLaserTemp Float, gs1000stateFlagLaserTemp INTEGER, gs1000minValueLaserTemp Float, gs1000maxValueLaserTemp Float, gs1000alarmStateLaserTemp INTEGER, gs1000labelLaserBias DisplayString (SIZE (0..80)), gs1000uomLaserBias DisplayString (SIZE (0..80)), gs1000majorHighLaserBias Float, gs1000majorLowLaserBias Float, gs1000minorHighLaserBias Float, gs1000minorLowLaserBias Float, gs1000currentValueLaserBias Float, gs1000stateFlagLaserBias INTEGER, gs1000minValueLaserBias Float, gs1000maxValueLaserBias Float, gs1000alarmStateLaserBias INTEGER, gs1000labelTecCurrent DisplayString (SIZE (0..80)), gs1000uomTecCurrent DisplayString (SIZE (0..80)), gs1000majorHighTecCurrent Float, gs1000majorLowTecCurrent Float, gs1000minorHighTecCurrent Float, gs1000minorLowTecCurrent Float, gs1000currentValueTecCurrent Float, gs1000stateFlagTecCurrent INTEGER, gs1000minValueTecCurrent Float, gs1000maxValueTecCurrent Float, gs1000alarmStateTecCurrent INTEGER, gs1000labelModuleTemp DisplayString (SIZE (0..80)), gs1000uomModuleTemp DisplayString (SIZE (0..80)), gs1000majorHighModuleTemp Float, gs1000majorLowModuleTemp Float, gs1000minorHighModuleTemp Float, gs1000minorLowModuleTemp Float, gs1000currentValueModuleTemp Float, gs1000stateFlagModuleTemp INTEGER, gs1000minValueModuleTemp Float, gs1000maxValueModuleTemp Float, gs1000alarmStateModuleTemp INTEGER, gs1000labelFan1Speed DisplayString (SIZE (0..80)), gs1000uomFan1Speed DisplayString (SIZE (0..80)), gs1000majorHighFan1Speed Float, gs1000majorLowFan1Speed Float, gs1000minorHighFan1Speed Float, gs1000minorLowFan1Speed Float, gs1000currentValueFan1Speed Float, gs1000stateFlagFan1Speed INTEGER, gs1000minValueFan1Speed Float, gs1000maxValueFan1Speed Float, gs1000alarmStateFan1Speed INTEGER, gs1000labelFan2Speed DisplayString (SIZE (0..80)), gs1000uomFan2Speed DisplayString (SIZE (0..80)), gs1000majorHighFan2Speed Float, gs1000majorLowFan2Speed Float, gs1000minorHighFan2Speed Float, gs1000minorLowFan2Speed Float, gs1000currentValueFan2Speed Float, gs1000stateFlagFan2Speed INTEGER, gs1000minValueFan2Speed Float, gs1000maxValueFan2Speed Float, gs1000alarmStateFan2Speed INTEGER, gs1000label12Volt DisplayString (SIZE (0..80)), gs1000uom12Volt DisplayString (SIZE (0..80)), gs1000majorHigh12Volt Float, gs1000majorLow12Volt Float, gs1000minorHigh12Volt Float, gs1000minorLow12Volt Float, gs1000currentValue12Volt Float, gs1000stateFlag12Volt INTEGER, gs1000minValue12Volt Float, gs1000maxValue12Volt Float, gs1000alarmState12Volt INTEGER } -- **************** Digital Parameters *********************** Gx2gs1000DigitalEntry ::= SEQUENCE { gx2gs1000DigitalTableIndex INTEGER, gs1000labelRfInput DisplayString (SIZE (0..80)), gs1000enumRfInput DisplayString (SIZE (0..80)), gs1000valueRfInput INTEGER, gs1000stateflagRfInput INTEGER, gs1000labelOptOutput DisplayString (SIZE (0..80)), gs1000enumOptOutput DisplayString (SIZE (0..80)), gs1000valueOptOutput INTEGER, gs1000stateflagOptOutput INTEGER, gs1000labelLaserMode DisplayString (SIZE (0..80)), gs1000enumLaserMode DisplayString (SIZE (0..80)), gs1000valueLaserMode INTEGER, gs1000stateflagLaserMode INTEGER, gs1000labelAttenSetting DisplayString (SIZE (0..80)), gs1000enumAttenSetting DisplayString (SIZE (0..80)), gs1000valueAttenSetting INTEGER, gs1000stateflagAttenSetting INTEGER, gs1000labelLaserSecMode DisplayString (SIZE (0..80)), gs1000enumLaserSecMode DisplayString (SIZE (0..80)), gs1000valueLaserSecMode INTEGER, gs1000stateflagLaserSecMode INTEGER, gs1000labelVideoOffset DisplayString (SIZE (0..80)), gs1000enumVideoOffset DisplayString (SIZE (0..80)), gs1000valueVideoOffset INTEGER, gs1000stateflagVideoOffset INTEGER, gs1000labelFactoryDefault DisplayString (SIZE (0..80)), gs1000enumFactoryDefault DisplayString (SIZE (0..80)), gs1000valueFactoryDefault INTEGER, gs1000stateflagFactoryDefault INTEGER } -- **************** Status Parameters ************************************ Gx2gs1000StatusEntry ::= SEQUENCE { gx2gs1000StatusTableIndex INTEGER, gs1000labelBoot DisplayString (SIZE (0..80)), gs1000valueBoot INTEGER, gs1000stateflagBoot INTEGER, gs1000labelFlash DisplayString (SIZE (0..80)), gs1000valueFlash INTEGER, gs1000stateflagFlash INTEGER, gs1000labelFactoryDataCRC DisplayString (SIZE (0..80)), gs1000valueFactoryDataCRC INTEGER, gs1000stateflagFactoryDataCRC INTEGER, gs1000labelLaserDataCRC DisplayString (SIZE (0..80)), gs1000valueLaserDataCRC INTEGER, gs1000stateflagLaserDataCRC INTEGER, gs1000labelAlarmDataCrc DisplayString (SIZE (0..80)), gs1000valueAlarmDataCrc INTEGER, gs1000stateflagAlarmDataCrc INTEGER, gs1000labelRFInputStatus DisplayString (SIZE (0..80)), gs1000valueRFInputStatus INTEGER, gs1000stateflagRFInputStatus INTEGER } -- **************** Factory Parameters ************************************* Gx2gs1000FactoryEntry ::= SEQUENCE { gx2gs1000FactoryTableIndex INTEGER, gs1000bootControlByteValue INTEGER, gs1000bootStatusByteValue INTEGER, gs1000bank1CRCValue INTEGER, gs1000bank2CRCValue INTEGER, gs1000prgEEPROMByteValue INTEGER, gs1000factoryCRCValue INTEGER, gs1000calculateCRCValue INTEGER, gs1000hourMeterValue INTEGER, gs1000flashPrgCntAValue INTEGER, gs1000flashPrgCntBValue INTEGER, gs1000flashBankARevValue DisplayString (SIZE (0..80)), gs1000flashBankBRevValue DisplayString (SIZE (0..80)) } -- ************** Analog Parameters **************************** gx2gs1000AnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2gs1000AnalogEntry 1} -- New Parameter gs1000labelOffsetNomMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Monitor Analog parameter." ::= { gx2gs1000AnalogEntry 2} gs1000uomOffsetNomMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter." ::= { gx2gs1000AnalogEntry 3} gs1000majorHighOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 4} gs1000majorLowOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 5} gs1000minorHighOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 6} gs1000minorLowOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 7} gs1000currentValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 8} gs1000stateFlagOffsetNomMonitor OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)" ::= { gx2gs1000AnalogEntry 9} gs1000minValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 10} gs1000maxValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 11} gs1000alarmStateOffsetNomMonitor OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Offset Monitor Analog parameter." ::= { gx2gs1000AnalogEntry 12} -- New Parameter gs1000labelOffsetNomCnt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Control Analog parameter." ::= { gx2gs1000AnalogEntry 13} gs1000uomOffsetNomCnt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Control Analog parameter." ::= { gx2gs1000AnalogEntry 14} gs1000majorHighOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 15} gs1000majorLowOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 16} gs1000minorHighOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 17} gs1000minorLowOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 18} gs1000currentValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 19} gs1000stateFlagOffsetNomCnt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)" ::= { gx2gs1000AnalogEntry 20} gs1000minValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 21} gs1000maxValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 22} gs1000alarmStateOffsetNomCnt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Offset Control Analog parameter." ::= { gx2gs1000AnalogEntry 23} -- New Parameter gs1000labelOptPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2gs1000AnalogEntry 24} gs1000uomOptPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2gs1000AnalogEntry 25} gs1000majorHighOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 26} gs1000majorLowOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 27} gs1000minorHighOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 28} gs1000minorLowOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 29} gs1000currentValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 30} gs1000stateFlagOptPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000AnalogEntry 31} gs1000minValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 32} gs1000maxValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 33} gs1000alarmStateOptPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2gs1000AnalogEntry 34} -- New Parameter gs1000labelLaserTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Temperature Analog parameter." ::= { gx2gs1000AnalogEntry 35} gs1000uomLaserTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter." ::= { gx2gs1000AnalogEntry 36} gs1000majorHighLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 37} gs1000majorLowLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 38} gs1000minorHighLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 39} gs1000minorLowLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 40} gs1000currentValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 41} gs1000stateFlagLaserTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000AnalogEntry 42} gs1000minValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 43} gs1000maxValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 44} gs1000alarmStateLaserTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Temperature Analog parameter." ::= { gx2gs1000AnalogEntry 45} -- New Parameter gs1000labelLaserBias OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Bias Current Analog parameter." ::= { gx2gs1000AnalogEntry 46} gs1000uomLaserBias OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Bias Analog parameter." ::= { gx2gs1000AnalogEntry 47} gs1000majorHighLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 48} gs1000majorLowLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 49} gs1000minorHighLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 50} gs1000minorLowLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 51} gs1000currentValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 52} gs1000stateFlagLaserBias OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000AnalogEntry 53} gs1000minValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 54} gs1000maxValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 55} gs1000alarmStateLaserBias OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Bias Analog parameter." ::= { gx2gs1000AnalogEntry 56} -- New Parameter gs1000labelTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Current Analog parameter." ::= { gx2gs1000AnalogEntry 57} gs1000uomTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the TEC Current Analog parameter.." ::= { gx2gs1000AnalogEntry 58} gs1000majorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 59} gs1000majorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 60} gs1000minorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 61} gs1000minorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 62} gs1000currentValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 63} gs1000stateFlagTecCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000AnalogEntry 64} gs1000minValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 65} gs1000maxValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 66} gs1000alarmStateTecCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the TEC Current Analog parameter." ::= { gx2gs1000AnalogEntry 67} -- New Parameter gs1000labelModuleTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2gs1000AnalogEntry 68} gs1000uomModuleTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2gs1000AnalogEntry 69} gs1000majorHighModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 70} gs1000majorLowModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 71} gs1000minorHighModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 72} gs1000minorLowModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 73} gs1000currentValueModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 74} gs1000stateFlagModuleTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000AnalogEntry 75} gs1000minValueModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 76} gs1000maxValueModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 77} gs1000alarmStateModuleTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2gs1000AnalogEntry 78} -- New Parameter gs1000labelFan1Speed OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan 1 Speed Analog parameter." ::= { gx2gs1000AnalogEntry 79} gs1000uomFan1Speed OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan 1 Speed Analog parameter." ::= { gx2gs1000AnalogEntry 80} gs1000majorHighFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Major High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 81} gs1000majorLowFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 82} gs1000minorHighFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 83} gs1000minorLowFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 84} gs1000currentValueFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 85} gs1000stateFlagFan1Speed OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan 1 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000AnalogEntry 86} gs1000minValueFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 87} gs1000maxValueFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 88} gs1000alarmStateFan1Speed OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan 1 Speed Analog parameter." ::= { gx2gs1000AnalogEntry 89 } -- New Parameter gs1000labelFan2Speed OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan 2 Speed Analog parameter." ::= { gx2gs1000AnalogEntry 90 } gs1000uomFan2Speed OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan 2 Speed Analog parameter." ::= { gx2gs1000AnalogEntry 91 } gs1000majorHighFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Major High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 92 } gs1000majorLowFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 93 } gs1000minorHighFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2gs1000AnalogEntry 94 } gs1000minorLowFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 95 } gs1000currentValueFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 96 } gs1000stateFlagFan2Speed OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan 2 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000AnalogEntry 97 } gs1000minValueFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 98 } gs1000maxValueFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 99 } gs1000alarmStateFan2Speed OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan 2 Speed Analog parameter." ::= { gx2gs1000AnalogEntry 100} -- New Parameter gs1000label12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the 12v Current Analog parameter." ::= { gx2gs1000AnalogEntry 101} gs1000uom12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v Current Analog parameter." ::= { gx2gs1000AnalogEntry 102} gs1000majorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 103} gs1000majorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 104} gs1000minorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 105} gs1000minorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 106} gs1000currentValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 107} gs1000stateFlag12Volt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000AnalogEntry 108} gs1000minValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 109} gs1000maxValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2gs1000AnalogEntry 110} gs1000alarmState12Volt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the 12v Current Analog parameter." ::= { gx2gs1000AnalogEntry 111} -- ************************ Digital parameters ********************************** gx2gs1000DigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2gs1000DigitalEntry 1} -- New parameter gs1000labelRfInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Input Control Digital parameter." ::= { gx2gs1000DigitalEntry 2} gs1000enumRfInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2gs1000DigitalEntry 3} gs1000valueRfInput OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2gs1000DigitalEntry 4} gs1000stateflagRfInput OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000DigitalEntry 5} -- New parameter gs1000labelOptOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Output Control Digital parameter." ::= { gx2gs1000DigitalEntry 6} gs1000enumOptOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2gs1000DigitalEntry 7} gs1000valueOptOutput OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2gs1000DigitalEntry 8} gs1000stateflagOptOutput OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the gs1000state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000DigitalEntry 9} -- New parameter gs1000labelLaserMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Mode Digital parameter." ::= { gx2gs1000DigitalEntry 10} gs1000enumLaserMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2gs1000DigitalEntry 11} gs1000valueLaserMode OBJECT-TYPE SYNTAX INTEGER { preset(1), set(2), setEquate(3), manual(4), manualEquate(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2gs1000DigitalEntry 12} gs1000stateflagLaserMode OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000DigitalEntry 13} -- New parameter gs1000labelAttenSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Attenuation Setting Ditital Parameter." ::= { gx2gs1000DigitalEntry 14} gs1000enumAttenSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2gs1000DigitalEntry 15} gs1000valueAttenSetting OBJECT-TYPE SYNTAX INTEGER { attn0pt0(1), attn0pt5(2), attn1pt0(3), attn1pt5(4), attn2pt0(5), attn2pt5(6), attn3pt0(7), attn3pt5(8), attn4pt0(9), attn4pt5(10), attn5pt0(11), attn5pt5(12), attn6pt0(13), attn6pt5(14), attn7pt0(15), attn7pt5(16), attn8pt0(17), attn8pt5(18), attn9pt0(19), attn9pt5(20), attn10pt0(21), attn10pt5(22), attn11pt0(23), attn11pt5(24), attn12pt0(25) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2gs1000DigitalEntry 16} gs1000stateflagAttenSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000DigitalEntry 17} -- New parameter gs1000labelLaserSecMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Secondary Mode Digital parameter." ::= { gx2gs1000DigitalEntry 18} gs1000enumLaserSecMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2gs1000DigitalEntry 19} gs1000valueLaserSecMode OBJECT-TYPE SYNTAX INTEGER { cw(1), video(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2gs1000DigitalEntry 20} gs1000stateflagLaserSecMode OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000DigitalEntry 21} -- New parameter gs1000labelVideoOffset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Video Offset Digital parameter." ::= { gx2gs1000DigitalEntry 22} gs1000enumVideoOffset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.." ::= { gx2gs1000DigitalEntry 23} gs1000valueVideoOffset OBJECT-TYPE SYNTAX INTEGER { minus1dB(1), minus2dB(2), minus3dB(3), minus4dB(4), minus5dB(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2gs1000DigitalEntry 24} gs1000stateflagVideoOffset OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000DigitalEntry 25} -- New parameter gs1000labelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2gs1000DigitalEntry 26} gs1000enumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2gs1000DigitalEntry 27} gs1000valueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2gs1000DigitalEntry 28} gs1000stateflagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000DigitalEntry 29} --*********** STATUS ***************** gx2gs1000StatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2gs1000StatusEntry 1} --New Parameter gs1000labelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2gs1000StatusEntry 2} gs1000valueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2gs1000StatusEntry 3} gs1000stateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000StatusEntry 4} --New Parameter gs1000labelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2gs1000StatusEntry 5} gs1000valueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2gs1000StatusEntry 6} gs1000stateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000StatusEntry 7} --New Parameter gs1000labelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2gs1000StatusEntry 8} gs1000valueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2gs1000StatusEntry 9} gs1000stateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000StatusEntry 10} --New Parameter gs1000labelLaserDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Data CRC Status parameter." ::= { gx2gs1000StatusEntry 11} gs1000valueLaserDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2gs1000StatusEntry 12} gs1000stateflagLaserDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000StatusEntry 13} --New Parameter gs1000labelAlarmDataCrc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2gs1000StatusEntry 14} gs1000valueAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2gs1000StatusEntry 15} gs1000stateflagAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000StatusEntry 16} --New Parameter gs1000labelRFInputStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Input Status parameter." ::= { gx2gs1000StatusEntry 17} gs1000valueRFInputStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2gs1000StatusEntry 18} gs1000stateflagRFInputStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2gs1000StatusEntry 19} -- ************ FACTORY DATA **************** gx2gs1000FactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2gs1000FactoryEntry 1} gs1000bootControlByteValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2gs1000FactoryEntry 2} gs1000bootStatusByteValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot" ::= { gx2gs1000FactoryEntry 3} gs1000bank1CRCValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0." ::= { gx2gs1000FactoryEntry 4} gs1000bank2CRCValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1." ::= { gx2gs1000FactoryEntry 5} gs1000prgEEPROMByteValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2gs1000FactoryEntry 6} gs1000factoryCRCValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2gs1000FactoryEntry 7} gs1000calculateCRCValue OBJECT-TYPE SYNTAX INTEGER { factory(1), laserData(2), alarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which of the Emnums will have the CRC calculated." ::= { gx2gs1000FactoryEntry 8} gs1000hourMeterValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2gs1000FactoryEntry 9} gs1000flashPrgCntAValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2gs1000FactoryEntry 10} gs1000flashPrgCntBValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2gs1000FactoryEntry 11} gs1000flashBankARevValue OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 0." ::= { gx2gs1000FactoryEntry 12} gs1000flashBankBRevValue OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 1." ::= { gx2gs1000FactoryEntry 13} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** -- ************************************************************************** -- GS 1000 Laser Module traps -- ************************************************************************** trapGS1000ConfigChangeInteger TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapGS1000ConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapGS1000RFInputAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapGS1000RFOverloadAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapGS1000RFOffsetAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 5 trapGS1000OpticalPowerAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 6 trapGS1000LaserBiasAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 7 trapGS1000LaserTempAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 8 trapGS1000TECCurrentAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 9 trapGS1000Fan1SpeedAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules Fan 1 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 10 trapGS1000Fan2SpeedAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules Fan 2 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 11 trapGS100012vAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 12 trapGS1000ModuleTempAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Module Temperature goes out of range." ::= 13 trapGS1000FlashAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error during Flash memory operations." ::= 14 trapGS1000LaserBiasCntLoopAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation." ::= 15 trapGS1000BankBootAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1." ::= 16 trapGS1000LaserBiasCntLoopInitAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Bias Control loop init fails." ::= 17 trapGS1000RFParamInitAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RF parameter Init fails." ::= 18 trapGS1000TECParamInitAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the TEC Parameter Init fails." ::= 19 trapGS1000AttnTableInitAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Attenuator Table Init fails." ::= 20 trapGS1000PowerMeterTableInitAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Power Meter Table Init fails." ::= 21 trapGS1000LaserDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Data CRC is incorrect." ::= 22 trapGS1000AlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Alarm Data CRC is incorrect." ::= 23 trapGS1000FactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Data CRC is incorrect." ::= 24 trapGS1000UserRFOffAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the the User RF is turned off." ::= 25 trapGS1000UserOpticalOffAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the User Optical Power is turned off." ::= 26 trapGS1000ResetFactoryDefaultAlarm TRAP-TYPE ENTERPRISE gx2Gs1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Default Reset occurs." ::= 27 END