| OID symbolic | OID numeric | Type | Access | Description |
| NTF trapLitepsConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.23.0.1 | | | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
| NTF trapLitepsConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.23.0.2 | | | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
| NTF trapLitepsFanCurrent1 | 1.3.6.1.4.1.1166.6.1.2.23.0.3 | | | This trap is issued when Fan 1 is in an alarm condition. |
| NTF trapLitepsFanCurrent2 | 1.3.6.1.4.1.1166.6.1.2.23.0.4 | | | This trap is issued when Fan 2 is in an alarm condition. |
| NTF trapLiteps12Volt | 1.3.6.1.4.1.1166.6.1.2.23.0.5 | | | This trap is issued when the 12 Volts is in an alarm condition. |
| NTF trapLiteps5Volt | 1.3.6.1.4.1.1166.6.1.2.23.0.6 | | | This trap is issued when the 5.1 Volts is in an alarm condition. |
| NTF trapLiteps3Volt | 1.3.6.1.4.1.1166.6.1.2.23.0.7 | | | This trap is issued when the 3.7 Volts is in an alarm condition. |
| gx2LitepsDescriptor | 1.3.6.1.4.1.1166.6.1.2.23.1 | | | |
| gx2LitepsAnalogTable | 1.3.6.1.4.1.1166.6.1.2.23.2 | | not-accessible | This table contains gx2Liteps specific parameters with
nominal and current values. |
| gx2LitepsAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.23.2.1 | | not-accessible | This list contains digital product class and the
associated RF channel parameters and descriptions. |
| INT gx2LitepsAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.23.2.1.1 | INTEGER | read-only | The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
| STR litepslabel12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.2 | DisplayString | read-only | The value of this object provides the label of the 12 Volt Analog parameter. |
| STR litepsuom12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.3 | DisplayString | read-only | The value of this object provides the unit of measure of the 12 Volt
Analog parameter. |
| FLO litepsmajorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
| FLO litepsmajorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
| FLO litepsminorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
| FLO litepsminorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
| FLO litepscurrentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.8 | Float | read-only | The value of this object provides the Current value of the 12 Volt Analog
parameter. This value is a floating point number that is represented as an
IEEE 32 Bit number. |
| INT litepsstateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.9 | INTEGER | read-only | The value of this object provides the state of the 12 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable) |
| FLO litepsminValue12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.10 | Float | read-only | The value of this object provides the minimum value the 12 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
| FLO litepsmaxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.11 | Float | read-only | The value of this object provides the maximum value the 12 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
| INT litepsalarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12 Volt Analog
parameter. |
| STR litepslabel5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Attenuator Setting Analog
parameter. |
| STR litepsuom5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 5 Volt Analog
parameter. |
| FLO litepsmajorHigh5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
| FLO litepsmajorLow5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
| FLO litepsminorHigh5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
| FLO litepsminorLow5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
| FLO litepscurrentValue5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.19 | Float | read-only | The value of this object provides the Current value of the 5 Volt Analog
parameter. This value is a floating point number that is represented as
an IEEE 32 Bit number. |
| INT litepsstateFlag5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.20 | INTEGER | read-only | The value of this object provides the state of the 5 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable). |
| FLO litepsminValue5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.21 | Float | read-only | The value of this object provides the minimum value the 5 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
| FLO litepsmaxValue5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.22 | Float | read-only | The value of this object provides the maximum value the 5 Volt Analog parameter
can achieve. This value is a floating point number that is represented as an
IEEE 32 Bit number. |
| INT litepsalarmState5Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the 5 Volt
Analog parameter. |
| STR litepslabel3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.24 | DisplayString | read-only | The value of this object provides the label of the
3 Anode Volt Analog parameter. |
| STR litepsuom3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 3.7V anode voltage
analog parameter. |
| FLO litepsmajorHigh3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
| FLO litepsmajorLow3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
| FLO litepsminorHigh3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
| FLO litepsminorLow3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
| FLO litepscurrentValue3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.30 | Float | read-only | The value of this object provides the Current value of the 3.7V anode voltage
analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
| INT litepsstateFlag3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.31 | INTEGER | read-only | The value of this object provides the state of the 3 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable). |
| FLO litepsminValue3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.32 | Float | read-only | The value of this object provides the minimum value that the 3.7V anode voltage
analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
| FLO litepsmaxValue3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.33 | Float | read-only | The value of this object provides the maximum value that the 3.7V anode voltage
analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
| INT litepsalarmState3Volt | 1.3.6.1.4.1.1166.6.1.2.23.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the 3.7V anode
voltage analog parameter. |
| gx2LitepsStatusTable | 1.3.6.1.4.1.1166.6.1.2.23.3 | | not-accessible | This table contains gx2Liteps specific parameters with
nominal and current values. |
| gx2LitepsStatusEntry | 1.3.6.1.4.1.1166.6.1.2.23.3.2 | | not-accessible | This list contains digital product class and the
associated RF channel parameters and descriptions. |
| INT gx2LitepsStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.23.3.2.1 | INTEGER | read-only | The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
| STR litepslabelFan1Status | 1.3.6.1.4.1.1166.6.1.2.23.3.2.2 | DisplayString | read-only | The value of this object provides the label of the
Fan 1 Status parameter. |
| INT litepsvalueFan1Status | 1.3.6.1.4.1.1166.6.1.2.23.3.2.3 | INTEGER | read-only | The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT litepsstateflagFan1Status | 1.3.6.1.4.1.1166.6.1.2.23.3.2.4 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR litepslabelFan2Status | 1.3.6.1.4.1.1166.6.1.2.23.3.2.5 | DisplayString | read-only | The value of this object provides the label of the
Fan 2 Status parameter. |
| INT litepsvalueFan2Status | 1.3.6.1.4.1.1166.6.1.2.23.3.2.6 | INTEGER | read-only | The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT litepsstateflagFan2Status | 1.3.6.1.4.1.1166.6.1.2.23.3.2.7 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |