All MIBs › GESINGLEUPS-MIB › upsBatteryStatusgen
upsBatteryStatusgen
Module: GESINGLEUPS-MIB
OID (symbolic): GESINGLEUPS-MIB::upsBatteryStatusgen
OID (numeric): 1.3.6.1.4.1.818.1.1.10.2.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).(*)
What is upsBatteryStatusgen?
Indicates the overall condition of the UPS battery: unknown, normal, low, or depleted. A value of batteryLow means the remaining run-time has fallen to or below the configured upsConfigLowBattTimegen threshold, while batteryDepleted warns that the UPS could not sustain the current load if utility power were lost right now.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.818.1.1.10.2.1 snmpwalk -v2c -c public <target> GESINGLEUPS-MIB::upsBatteryStatusgen
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.818.1.1.10.2.1.1 snmpget -v2c -c public <target> GESINGLEUPS-MIB::upsBatteryStatusgen.1
Start monitoring GE Digital Energy single-unit UPS system with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GESINGLEUPS-MIB::upsBatteryStatusgen OID value, configure state conditions and alerts, and monitor any GE Digital Energy single-unit UPS system from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.818 | imv | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1 | geHardware | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1.1 | geUPS | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1.1.10 | geGenericUPS | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1.1.10.2 | upsBattery_gen | GE-PARALLELUPS |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.818.1.1.10.2.1 | upsBatteryStatusgen | GESINGLEUPS-MIB |