All MIBs › GESINGLEUPS-MIB › upsReceptacleOnOffgen
upsReceptacleOnOffgen
Module: GESINGLEUPS-MIB
OID (symbolic): GESINGLEUPS-MIB::upsReceptacleOnOffgen
OID (numeric): 1.3.6.1.4.1.818.1.1.10.8.7.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The present state of the receptacle. Setting this object to 'on' will cause the receptacle to be turned on. Setting this object to 'off' will turn the receptacle off. If the receptacle is already in the desired state nothing will happen. After an autorestart (see upsAutoRestart) the receptacle will be on.
What is upsReceptacleOnOffgen?
Controls and reports the on/off state of one switched receptacle: setting it to 'on' or 'off' switches that outlet, with no effect if it's already in the requested state. After an auto-restart (see upsAutoRestartgen), the receptacle always comes back on regardless of its state before the shutdown.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.818.1.1.10.8.7.1.2 snmpwalk -v2c -c public <target> GESINGLEUPS-MIB::upsReceptacleOnOffgen
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.818.1.1.10.8.7.1.2.1 snmpget -v2c -c public <target> GESINGLEUPS-MIB::upsReceptacleOnOffgen.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.818.1.1.10.8.7.1.2.1 i <value>
Start monitoring GE Digital Energy single-unit UPS system with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GESINGLEUPS-MIB::upsReceptacleOnOffgen OID value, configure state conditions and alerts, and monitor any GE Digital Energy single-unit UPS system from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.818 | imv | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1 | geHardware | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1.1 | geUPS | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1.1.10 | geGenericUPS | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1.1.10.8 | upsControl_gen | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1.1.10.8.7 | upsReceptacleTable_gen | GE-PARALLELUPS |
| 1.3.6.1.4.1.818.1.1.10.8.7.1 | upsReceptacleEntry_gen | GE-PARALLELUPS |
| Numeric OID | Name | Module |
|---|---|---|