Organization: Cisco Small Business

Last Updated: 2007-01-02

Category: Device Management, Vendor: RADLAN/Cisco SB

Description:

Holds device-level configuration parameters, such as system settings and identification, for Cisco Small Business (formerly Linksys/Radlan) managed switches.

Imported Objects

From CISCOSB-MIB

switch001MODULE-IDENTITY

From SNMPv2-SMI

IpAddress
MODULE-IDENTITY
OBJECT-TYPE

From SNMPv2-TC

DisplayString
PhysAddress
TruthValue

What Is CISCOSB-DEVICEPARAMS-MIB?

CISCOSB-DEVICEPARAMS-MIB is a Cisco Small Business private enterprise MIB (inherited from the Linksys/Radlan switch platform) that defines general device-level parameters for entry-level managed switches. It exposes objects covering bridge/device identity and versioning, error and alarm reporting, SNMP community-based access control, and basic IP host management. Its monitoring value centers on software status and fault visibility: objects like rndBrgVersion and rndBrgFeatures report firmware version and licensed feature set, while rndErrorDesc, rndErrorSeverity, and rndBridgeAlarm surface device fault conditions and their severity. It builds on the underlying Radlan bridge management architecture shared across several Cisco Small Business switch MIBs, rather than standard IETF bridge MIBs alone. It is deployed on small-office/branch Cisco Small Business (formerly Linksys) managed switches where centralized network management tools poll basic device health and access-control settings. Network engineers often consult the CISCOSB-DEVICEPARAMS-MIB MIB Browser view to walk these objects directly when troubleshooting a specific switch's firmware version or alarm condition.

IPNetwork Monitor allows you to monitor SNMP objects defined in CISCOSB-DEVICEPARAMS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • firmware/bridge version
  • licensed feature set
  • error severity and description
  • bridge alarm status
  • SNMP community access control
  • ARP inactivity timeout

Supported Devices

  • Cisco Catalyst 1300-8T (2024) — current successor switch line to the discontinued CBS350 Small Business series
  • Cisco Catalyst 1200-8T-D — current successor switch line to the discontinued CBS250 Small Business series
  • Cisco Small Business switches

Monitoring Examples

An operator can read rndBrgVersion to confirm the switch's firmware version after an upgrade, and watch rndErrorDesc together with rndErrorSeverity for a reported fault whose associated rndBridgeAlarm indicates an active alarm condition. The rndCommunityTable/rndCommunityEntry rows (rndCommunityMngStationAddr, rndCommunityString, rndCommunityAccess) let an administrator audit which management stations have SNMP access and at what privilege level. rndInactiveArpTimeOut and rndIpHost/rndIpHostManagement round out basic ARP aging and device IP identity checks.

OIDs
OID symbolicOID numericTypeAccessDescription
rndDeviceParams1.3.6.1.4.1.9.6.1.101.2This private MIB module defines general Parameters private MIBs.
INT rndBridgeType1.3.6.1.4.1.9.6.1.101.2.1INTEGERread-onlyIdentification of the switch001 bridge type.
INT rndInactiveArpTimeOut1.3.6.1.4.1.9.6.1.101.2.2INTEGERread-writeThis variable defines the maximum time period that can pass between ARP requests concerning an entry in the ARP table. After this time period, the entry is deleted from the table.
rndBridgeAlarm1.3.6.1.4.1.9.6.1.101.2.3
STR rndErrorDesc1.3.6.1.4.1.9.6.1.101.2.3.1DisplayStringread-onlyA textual description of the enterprise-specific trap sent to the Network Management Station by the switch001 managed device.
INT rndErrorSeverity1.3.6.1.4.1.9.6.1.101.2.3.2INTEGERread-onlyThe severity type of the enterprise-specific trap sent to the Network Management Station by the switch001 managed device.
STR rndBrgVersion1.3.6.1.4.1.9.6.1.101.2.4DisplayStringread-onlyThe bridge version.
OCT rndBrgFeatures1.3.6.1.4.1.9.6.1.101.2.5OCTET STRINGread-onlyA bit mask that defines the features supported by a particular configuration of this network element: __________________________________________ | Byte 1|Byte 2 |Byte 3 | ....|Byte 20 | |87654321| | 87654321| |________|_______________________________| Byte1 : bit1: TX Block mask bit2: Source Routing Encapulation bit3: SNA/SDLC bit4: Frame Relay bit5: SNMP bit6: LAN Manager bit7: High Performance bit8: Translation Byte2 : bit1: DEC Router bit2: IPX Router bit3: IP Router Byte3 : bit1: Dial Up Backup bit2: COD bit3: FACS bit4: Load Balance bit5: Remote Configuration bit6: RIP 2 bit7: OSPF bit8: IPX RIP/SAP Filter Byte4 : bit1: BootP Server bit2: BootP Client bit3: Compression bit4: V25.bis bit5: ISDN bit6: CODv2 bit7: NSPF bit8: UDP Relay Byte5 bit1:VirtualLAN bit2:Static IP Multicast bit3:IP Redundancy bit4:CCM2 bit5:ISDN Bonding bit6:Backup Link Selection -- for the VAN/Rdapter ver 4.0 bit7:IP/IPX Forwarding -- for the WANgate ver 4.0 bit8:Improved COD Byte6 bit1: Server Disptacher bit2: ISDN_US -- for the VANSX/WANGATE ver 5.0 bit3: PPP bit4: IP Rip Filter -- for Vgate3 bit5: Zero Hop Routing -- for Vgate3 bit6: ISDN Japan bit7: PPP-Security Byte7 bit1: With unmanaged Switch bit2: 2 LANs bit3: OSPF Ver 2.0 bit4: FACS Ver 2.0 bit5: Multiple WEB Farm bit6: Backup Server bit7: Check Connectivity bit8: WSD multiplexing Byte8 bit1: MRT3 bit2: WSD Redundancy bit3: DHCP Server bit4: WSD Connection Limit bit5: WSD Distributed System bit6: WSD Load Report bit7: WSD super farm bit8: RadWiz leased line Byte9 bit1: PPP IP address negotiaton bit2: DNS bit3: Nat bit4: WSD Static proximity bit5: WSD Dynamic proximity bit6: WSD Proxy bit7: WSD Proximity client bit8: MAC Load balancing Byte10 bit1: Unnum Inf bit2: Power Supply redundancy bit3: MRT PPP Compression bit4: ZHR Apolo bit5: Copy port bit6: UDP Relay 2.0 bit7: NVRAM bit8: URL table Byte11 bit1: URL super farm bit2: NAT on LAN bit3: Remote Con bit4: AP5000 bit5: Session tracking bit6: Mirroring bit7: Alias IP bit8: CSD Nat Byte12 bit1: content check bit2: mlb virtual ip bit3: reserved CISCOSB bit4: csd nat exception bit5: statistics monitor bit6: reserved-for-radware
OCT rndBrgLicense1.3.6.1.4.1.9.6.1.101.2.6OCTET STRINGread-writeThis parameter is used for entering a s/w license number for a device. A separate license number is supplied for each device.
rndIpHost1.3.6.1.4.1.9.6.1.101.2.7
rndCommunityTable1.3.6.1.4.1.9.6.1.101.2.7.2not-accessibleThe community table of the agent
rndCommunityEntry1.3.6.1.4.1.9.6.1.101.2.7.2.1not-accessibleThe row definition for this table.
IP rndCommunityMngStationAddr1.3.6.1.4.1.9.6.1.101.2.7.2.1.1IpAddressread-createThe management station that will be allowed to communicate with the agent IP address
STR rndCommunityString1.3.6.1.4.1.9.6.1.101.2.7.2.1.2DisplayStringread-createThe community string with which the management station will communicate with the agent
INT rndCommunityAccess1.3.6.1.4.1.9.6.1.101.2.7.2.1.3INTEGERread-createThe allowed access to this management station
INT rndCommunityTrapsEnable1.3.6.1.4.1.9.6.1.101.2.7.2.1.4INTEGERread-createShould the agent send traps to the management station, and what version is required
INT rndCommunityStatus1.3.6.1.4.1.9.6.1.101.2.7.2.1.5INTEGERread-createThe status of this entry. If the status is invalid the community entry will be deleted
INT rndCommunityPortSecurity1.3.6.1.4.1.9.6.1.101.2.7.2.1.6INTEGERread-createIf enabled the device will only receive SNMP messages from the port, through which this NMS is reachable from the device.
STR rndCommunityOwner1.3.6.1.4.1.9.6.1.101.2.7.2.1.7DisplayStringread-createThe owner of this community
INT rndCommunityTrapDestPort1.3.6.1.4.1.9.6.1.101.2.7.2.1.8INTEGERread-createThe transport protocol (usually UDP) port to which traps to the management station represebted by this entry will be sent. The default is the well-known IANA assigned port number for SNMP traps. This object is relevant only if rndCommunityTrapsEnable has a value different from trapsDisable.
rlMridTable1.3.6.1.4.1.9.6.1.101.2.7.3not-accessibleThe MRID related configurations table of the agent
rlMridEntry1.3.6.1.4.1.9.6.1.101.2.7.3.1not-accessibleThe row definition for this table.
INT rlMridConnection1.3.6.1.4.1.9.6.1.101.2.7.3.1.1INTEGERread-writeThe router instance connecting the NMS who accessed the agent through the community table entry corresponding to the keys of this entry.
INT rlManagedMrid1.3.6.1.4.1.9.6.1.101.2.7.3.1.2INTEGERread-writeThe router instance currently managed by the NMS who accessed the agent through the community table entry corresponding to the keys of this entry
rndIpHostManagement1.3.6.1.4.1.9.6.1.101.2.7.4
T/F rndIpHostManagementSupported1.3.6.1.4.1.9.6.1.101.2.7.4.1TruthValueread-onlyifindex manage supported.
INT rndIpHostManagementIfIndex1.3.6.1.4.1.9.6.1.101.2.7.4.2INTEGERread-writeif supported manage , indicate ifindex, if 0 thaen disable
STR rndManagedTime1.3.6.1.4.1.9.6.1.101.2.8DisplayStringread-writeThe time will be sent in the format hhmmss
STR rndManagedDate1.3.6.1.4.1.9.6.1.101.2.9DisplayStringread-writeThe date will be sent in the format ddmmyy
STR rndBaseBootVersion1.3.6.1.4.1.9.6.1.101.2.10DisplayStringread-onlyDefines the boot version of the product.
genGroup1.3.6.1.4.1.9.6.1.101.2.11
STR genGroupHWVersion1.3.6.1.4.1.9.6.1.101.2.11.1DisplayStringread-onlyDefines the HW version of the product.
STR genGroupConfigurationSymbol1.3.6.1.4.1.9.6.1.101.2.11.2DisplayStringread-onlyDefines the Configuration Symbol attached to any hardware module manufactured by LANNET. One single character A..Z defines the CS version.
INT genGroupHWStatus1.3.6.1.4.1.9.6.1.101.2.11.3INTEGERread-onlyThis attribute describes the status of the group hardware as detected by the sensors software.
PHY rndBasePhysicalAddress1.3.6.1.4.1.9.6.1.101.2.12PhysAddressread-onlyThe Base physical (MAC) address of the device.
rndSoftwareFile1.3.6.1.4.1.9.6.1.101.2.13
rndActiveSoftwareFileTable1.3.6.1.4.1.9.6.1.101.2.13.1not-accessibleThe (conceptual) table listing the active software file of the requested unit.
rndActiveSoftwareFileEntry1.3.6.1.4.1.9.6.1.101.2.13.1.1not-accessibleAn entry (conceptual row) in the rndActiveSoftwareFileTable.
INT rndUnitNumber1.3.6.1.4.1.9.6.1.101.2.13.1.1.1INTEGERread-writeThe unit number (for stackable devices) or 1 for 'stand alone' device.
RLI rndActiveSoftwareFile1.3.6.1.4.1.9.6.1.101.2.13.1.1.2RlImageIdTyperead-onlyIndicates the current active software file, image1 or image2.
INT rndActiveSoftwareFileAfterReset1.3.6.1.4.1.9.6.1.101.2.13.1.1.3INTEGERread-writeIndicates the software file that will be active after reset (image1 or image2). If an error occurred in the download process, resulting in the corruption of the single software file, The value 'invalidImage' will be returned. This value can not be set by the user.
BIT rlResetStatus1.3.6.1.4.1.9.6.1.101.2.13.2Bitsread-onlyA bit mask that specifies system status before reset action is preformed. Reset is prohibited in stackable products if the images selected after reboot are not of the same release version in ALL stack units. Downgrade status specifies that there are some actions to be preformed on the CDB file before reset is preformed. 0x0 - OK 0x1 - noStackIntegrity 0x2 - downgrade
INT rndImageSize1.3.6.1.4.1.9.6.1.101.2.14INTEGERread-onlyMax number of sectors currently allocated for image(s).
T/F rndBackupConfigurationEnabled1.3.6.1.4.1.9.6.1.101.2.15TruthValueread-onlySpecifies whether the device supports backup-config parameters in lcli commands.
rndImageInfo1.3.6.1.4.1.9.6.1.101.2.16
rndImageInfoTable1.3.6.1.4.1.9.6.1.101.2.16.1not-accessibleThe table contains information about images.
rndImageInfoEntry1.3.6.1.4.1.9.6.1.101.2.16.1.1not-accessibleAn entry in the rndImageInfoTable.
INT rndStackUnitNumber1.3.6.1.4.1.9.6.1.101.2.16.1.1.1INTEGERread-writeThe unit number (for stackable devices) or 1 for 'stand alone' device.
STR rndImage1Name1.3.6.1.4.1.9.6.1.101.2.16.1.1.2DisplayStringread-onlyIndicates the file name of image-1 in the system.
STR rndImage2Name1.3.6.1.4.1.9.6.1.101.2.16.1.1.3DisplayStringread-onlyIndicates the file name of image-2 (if present) in the system.If image-2 is not present show 'no info' text
STR rndImage1Version1.3.6.1.4.1.9.6.1.101.2.16.1.1.4DisplayStringread-onlyIndicates the version of image-1 in the system.
STR rndImage2Version1.3.6.1.4.1.9.6.1.101.2.16.1.1.5DisplayStringread-onlyIndicates the version of image-2 (if present) in the system.If image-2 is not present show 'no info' text
STR rndImage1Date1.3.6.1.4.1.9.6.1.101.2.16.1.1.6DisplayStringread-onlyIndicates the compilation date of image-1 in the system.
STR rndImage2Date1.3.6.1.4.1.9.6.1.101.2.16.1.1.7DisplayStringread-onlyIndicates the compilation date of image-2 (if present) in the system.If image-2 is not present show 'no info' text
STR rndImage1Time1.3.6.1.4.1.9.6.1.101.2.16.1.1.8DisplayStringread-onlyIndicates the compilation time of image-1 in the system.
STR rndImage2Time1.3.6.1.4.1.9.6.1.101.2.16.1.1.9DisplayStringread-onlyIndicates the compilation time of image-2 (if present) in the system.If image-2 is not present show 'no info' text
STR rndImage1Description1.3.6.1.4.1.9.6.1.101.2.16.1.1.10DisplayStringread-writeIndicates the description of image-1 in the system.
STR rndImage2Description1.3.6.1.4.1.9.6.1.101.2.16.1.1.11DisplayStringread-writeIndicates the description of image-2 in the system.
rlComponentsInfoTable1.3.6.1.4.1.9.6.1.101.2.16.2not-accessibleThe table contains information about components, their streams and baselines in the device images.
rlComponentsInfoEntry1.3.6.1.4.1.9.6.1.101.2.16.2.1not-accessibleAn entry in the rlComponentsInfoTable.
INT rlComponentsInfoStackUnitNumber1.3.6.1.4.1.9.6.1.101.2.16.2.1.1INTEGERnot-accessibleThe unit number (for stackable devices) or 1 for 'stand alone' device.
RLI rlComponentsInfoImageId1.3.6.1.4.1.9.6.1.101.2.16.2.1.2RlImageIdTypenot-accessibleIndicates the image id in the unit
STR rlComponentsInfoComponent1.3.6.1.4.1.9.6.1.101.2.16.2.1.3DisplayStringnot-accessibleIndicates the SW component name.
STR rlComponentsInfoBaseline1.3.6.1.4.1.9.6.1.101.2.16.2.1.5DisplayStringread-onlyIndicates the version control baseline of the SW component name.

FAQ

How would I use CISCOSB-DEVICEPARAMS-MIB to check firmware version and alarm status on a Cisco Small Business switch?
rndBrgVersion and rndBrgFeatures report firmware version and licensed feature set, while rndErrorDesc, rndErrorSeverity, and rndBridgeAlarm surface fault conditions and their severity, giving a quick way to check both software version and current alarm state.

Can CISCOSB-DEVICEPARAMS-MIB help control SNMP access on these switches?
Yes, it includes SNMP community-based access control objects alongside basic IP host management, so you can review which communities have access as part of managing the switch's device-level parameters.

RFC description

Defines device-level configuration parameters for Cisco Small Business (formerly Linksys/Radlan) managed switches, including system settings and device identification.

Start monitoring Cisco Small Business switches with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download CISCOSB-DEVICEPARAMS-MIB