Description: Manages ADTRAN TSU IQ T1/FT1 service units with integrated quality monitoring capabilities.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is ADTRAN-TSUIQ-MIB?
ADTRAN-TSUIQ-MIB is an ADTRAN vendor MIB for the TSU IQ, a T1/Fractional T1 (FT1) terminal/service unit with integrated quality-monitoring circuitry used to terminate leased-line data circuits. It primarily exposes device configuration objects -- management IP addressing, gateway, trap-manager destination (including DLCI and port for frame-relay-delivered traps), console port baud rate and mode, and system password/date/time -- rather than deep line-quality counters in the sampled data. Its monitoring relevance lies in confirming the unit's management reachability and trap-delivery path are correctly configured, and, as an "IQ" (integrated quality) unit, in the broader product line's ability to report circuit quality and alarm conditions back to a management station via those configured trap destinations. No dependency on external standard MIBs is evident from the available definitions. It would be deployed at customer or network sites terminating T1/FT1 circuits where centralized SNMP trap monitoring of the unit's configuration and link quality is required, and technicians can download the ADTRAN-TSUIQ-MIB file to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ADTRAN-TSUIQ-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- ADTRAN TSU IQ T1/FT1 terminal/service unit
Monitoring Examples
An administrator would set adTSUIQIpAddress, adTSUIQIpAddressMask, and adTSUIQGatewayIpAddress to establish management access to the unit. adTSUIQTrapManagerIpAddress, along with adTSUIQTrapManagerDLCI and adTSUIQTrapManagerPort, would then be configured so trap notifications reach the NMS over the correct frame-relay path. adTSUIQEnableTraps would be checked to confirm traps are actually turned on, and adTSUIQTOD/adTSUIQDate would be read to verify the unit's clock is synchronized for accurate event timestamps.
What Can Be Monitored
- management IP address/mask/gateway configuration
- trap destination IP/DLCI/port
- trap enable status
- control/console port baud rate and mode
- time-of-day and date
This MIB depends on
Related MIBs
Imported Objects
From ADTRAN-MIB
| adMgmt | OBJECT-IDENTITY |
| adProdPhysAddress | OBJECT-TYPE |
| adProducts | OBJECT-IDENTITY |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| Gauge | |
| IpAddress | |
| enterprises |
From RFC1213-MIB
| DisplayString | |
| ifIndex |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| adTSUIQ | 1.3.6.1.4.1.664.1.147 | |||
| NTF adTSUIQNetworkPhysUp | 1.3.6.1.4.1.664.1.147.0.14701 | This trap indicates that the physical layer of the network is now up. | ||
| NTF adTSUIQNetworkPhysDown | 1.3.6.1.4.1.664.1.147.0.14702 | This trap indicates that the physical layer of the network is now down. | ||
| NTF adTSUIQNetworkLMIUp | 1.3.6.1.4.1.664.1.147.0.14703 | This trap indicates that the LMI state of the network is now up. | ||
| NTF adTSUIQNetworkLMIDown | 1.3.6.1.4.1.664.1.147.0.14704 | This trap indicates that the LMI state of the network is now down. | ||
| NTF adTSUIQColdStart | 1.3.6.1.4.1.664.1.147.0.14705 | This trap indicates that a cold start has occurred. | ||
| adTSUIQmg | 1.3.6.1.4.1.664.2.147 | |||
| adTSUIQSystemConfig | 1.3.6.1.4.1.664.2.147.1 | |||
| STR adTSUIQPassword | 1.3.6.1.4.1.664.2.147.1.1 | DisplayString | read-write | Sets the Telnet and Vt100 Control Password. |
| STR adTSUIQTOD | 1.3.6.1.4.1.664.2.147.1.2 | DisplayString | read-write | Sets the Time of Day with format hh:mm. |
| STR adTSUIQDate | 1.3.6.1.4.1.664.2.147.1.3 | DisplayString | read-write | Sets the Date with the format MM-DD-YY. |
| IP adTSUIQIpAddress | 1.3.6.1.4.1.664.2.147.1.4 | IpAddress | read-write | Sets the unit's IP Address. |
| IP adTSUIQIpAddressMask | 1.3.6.1.4.1.664.2.147.1.5 | IpAddress | read-write | Sets the Network Subnet Mask. |
| IP adTSUIQGatewayIpAddress | 1.3.6.1.4.1.664.2.147.1.6 | IpAddress | read-write | Sets the Network Gateway IP Address. |
| IP adTSUIQTrapManagerIpAddress | 1.3.6.1.4.1.664.2.147.1.7 | IpAddress | read-write | Sets the Trap Manager IP Address. |
| INT adTSUIQTrapManagerDLCI | 1.3.6.1.4.1.664.2.147.1.8 | INTEGER | read-write | Sets the Trap Manager DLCI. (Range 16 - 1007). |
| INT adTSUIQTrapManagerPort | 1.3.6.1.4.1.664.2.147.1.9 | INTEGER | read-write | Selects the Trap Manager Port. |
| INT adTSUIQControPortBaud | 1.3.6.1.4.1.664.2.147.1.10 | INTEGER | read-write | Selects the Control Port Baud Rate. |
| INT adTSUIQControPortMode | 1.3.6.1.4.1.664.2.147.1.11 | INTEGER | read-write | Selects the Control Port Mode. |
| INT adTSUIQEnableTraps | 1.3.6.1.4.1.664.2.147.1.12 | INTEGER | read-write | Overall trap enable/disable. |
| INT adTSUIQAlarmState | 1.3.6.1.4.1.664.2.147.1.13 | INTEGER | read-only | This bit map variable indicates alarm conditions which are currently set. When an alarm condition occurs, the corresponding event bit is set in this variable. If armed, setting the event will generate an Alarm Trap. The various alarm event bit positions are: 1 = Network physical link up. 2 = Network physical link down. 4 = Network signal state up. 8 = Network signal state down. |
| INT adTSUIQArmAlarm | 1.3.6.1.4.1.664.2.147.1.14 | INTEGER | read-write | This bit map variable arms or disarms an individual or group of events identified in adFradAlarmState as a source for generation of an Alarm Trap. The various arm event bit positions are : 1 = Network physical link up. 2 = Network physical link down. 4 = Network signal state up. 8 = Network signal state down. |
| INT adTSUIQAbortConfig | 1.3.6.1.4.1.664.2.147.1.15 | INTEGER | read-write | A Set will cancel current selections and reverts to the last saved configuration. |
| INT adTSUIQSaveConfig | 1.3.6.1.4.1.664.2.147.1.16 | INTEGER | read-write | A Set will reset the unit and Save the current selections. |
| adTSUIQNetPortConfig | 1.3.6.1.4.1.664.2.147.2 | |||
| INT adTSUIQNetPortFrameType | 1.3.6.1.4.1.664.2.147.2.1 | INTEGER | read-write | Frame type for T1 interface |
| INT adTSUIQNetPortClockSource | 1.3.6.1.4.1.664.2.147.2.2 | INTEGER | read-write | Timing source for the transmit side of the T1 interface. |
| INT adTSUIQNetPortLineCode | 1.3.6.1.4.1.664.2.147.2.3 | INTEGER | read-write | Line code for the the T1 interface. |
| INT adTSUIQNetRxSensitivity | 1.3.6.1.4.1.664.2.147.2.4 | INTEGER | read-write | Selects the gain of receiver for the T1 interface. |
| INT adTSUIQNetPortLBO | 1.3.6.1.4.1.664.2.147.2.5 | INTEGER | read-write | Line build out for the transmit side of the T1 interface. |
| INT adTSUIQNetChannelCount | 1.3.6.1.4.1.664.2.147.2.6 | INTEGER | read-write | Selects the number of active channels for the T1 interface. |
| INT adTSUIQNetChannelStart | 1.3.6.1.4.1.664.2.147.2.7 | INTEGER | read-write | Selects the channel that begins the active channel list for the T1 interface. |
| INT adTSUIQNetChannelBandwidth | 1.3.6.1.4.1.664.2.147.2.8 | INTEGER | read-write | Selects the amount of data in each active channel for the T1 interface. |
| INT adTSUIQNetChannelAlignment | 1.3.6.1.4.1.664.2.147.2.9 | INTEGER | read-write | Selects the alignment of active channels for the T1 interface. |
| INT adTSUIQNetTransmitPRM | 1.3.6.1.4.1.664.2.147.2.10 | INTEGER | read-write | Enables performance report generation across the T1 FDL for the T1 interface. |
| INT adTSUIQNetPortSignaling | 1.3.6.1.4.1.664.2.147.2.11 | INTEGER | read-write | Signaling type for the frame relay management interface. |
| INT adTSUIQNetPortt391 | 1.3.6.1.4.1.664.2.147.2.12 | INTEGER | read-write | Sets the polling interval in seconds for the frame relay management interface. (Range 5 - 30). |
| INT adTSUIQNetPortn391 | 1.3.6.1.4.1.664.2.147.2.13 | INTEGER | read-write | Sets the interval between full status polls for the frame relay management interface. (Range 1 - 255). |
| INT adTSUIQNetPortn392 | 1.3.6.1.4.1.664.2.147.2.14 | INTEGER | read-write | Sets the error count for the frame relay management interface. (Range 1 - 10). |
| INT adTSUIQNetPortn393 | 1.3.6.1.4.1.664.2.147.2.15 | INTEGER | read-write | Sets the event window for the frame relay management interface. ( Range 1 - 10). |
| INT adTSUIQNetPortMgmtDlci1Mode | 1.3.6.1.4.1.664.2.147.2.16 | INTEGER | read-write | Sets the mode for the managent DLCI 1. If set for shared, management DLCI 1 is used for customer data and IQ management data. If set for dedicated, management DLCI 1 is used only for IQ management data and is not passed to the attached frame relay DTE device. |
| INT adTSUIQNetPortMgmtDlci2Mode | 1.3.6.1.4.1.664.2.147.2.17 | INTEGER | read-write | Sets the mode for the managent DLCI 2. If set for shared, management DLCI 2 is used for customer data and IQ management data. If set for dedicated, management DLCI 2 is used only for IQ management data and is not passed to the attached frame relay DTE device. |
| INT adTSUIQNetMgmtDlci1 | 1.3.6.1.4.1.664.2.147.2.18 | INTEGER | read-write | Sets the address for management PVC 1. (Range 16 - 1007). |
| INT adTSUIQNetMgmtDlci2 | 1.3.6.1.4.1.664.2.147.2.19 | INTEGER | read-write | Sets the address for management PVC 2. (Range 16 - 1007). |
| INT adTSUIQNetPortMaxPVCs | 1.3.6.1.4.1.664.2.147.2.20 | INTEGER | read-write | Sets the maxium PVCs supported by the IQ unit. (Range 1 - 100). |
| INT adTSUIQNetPortHistIntervals | 1.3.6.1.4.1.664.2.147.2.21 | INTEGER | read-write | Sets the number of history intervals for storage. |
| INT adTSUIQNetPortHistIntervalsAvailable | 1.3.6.1.4.1.664.2.147.2.22 | INTEGER | read-only | Returns the number of history intervals allowed based on the maxium number of PVCs selected. |
| adTSUIQDtePortConfig | 1.3.6.1.4.1.664.2.147.3 | |||
| INT adTSUIQDteCTSOption | 1.3.6.1.4.1.664.2.147.3.1 | INTEGER | read-write | Selects the Clear to Send (CTS) option. |
| INT adTSUIQDteCDOption | 1.3.6.1.4.1.664.2.147.3.2 | INTEGER | read-write | Selects the Carrier Detect (CD) option. |
| INT adTSUIQDteDSROption | 1.3.6.1.4.1.664.2.147.3.3 | INTEGER | read-write | Selects the Data Set Ready (DSR) option. |
| INT adTSUIQDtePortMgmtDLCI | 1.3.6.1.4.1.664.2.147.3.4 | INTEGER | read-write | Selects the DTE Port Management DLCI. (Range 16 - 1007). |
| INT adTSUIQDtePortt392 | 1.3.6.1.4.1.664.2.147.3.5 | INTEGER | read-write | Sets the timeout in seconds between polling intervals. (Range 5 - 30).. |
| INT adTSUIQDtePortn392 | 1.3.6.1.4.1.664.2.147.3.6 | INTEGER | read-write | Sets the number of error events for the frame relay management. (Range 1 - 10).. |
| INT adTSUIQDtePortn393 | 1.3.6.1.4.1.664.2.147.3.7 | INTEGER | read-write | Sets the error window (polling events) for the frame relay management. (Range 1 - 10). |
| INT adTSUIQDteTCClockOption | 1.3.6.1.4.1.664.2.147.3.8 | INTEGER | read-write | Sets the phase of the DTE Transmit clock. |
| INT adTSUIQDteManagementPvcOption | 1.3.6.1.4.1.664.2.147.3.9 | INTEGER | read-write | Controls the presence of the DTE management PVC in a full status response to the DTE device. |
| INT adTSUIQDteSignalingResponsesOption | 1.3.6.1.4.1.664.2.147.3.10 | INTEGER | read-write | Determines how the IQ device will respond to polls from the DTE device during a network failure. If set to always on, the IQ will respond to polls during a network failure. If set to follow network, the IQ will not respond thus emulating a failure to the DTE device. If the IQ is responsible for dial backup, this option should be set to always on. |
| INT adTSUIQDteFlowControlOption | 1.3.6.1.4.1.664.2.147.3.11 | INTEGER | read-write | Determines how the IQ device will respond to congestion during DBU operation. If set for none, the IQ will drop frames during DBU operation when severe congestion occurs. If set for hardware, the IQ will vary the DTE TC clock in order to control the amount of data offered to the IQ when severe congestion occurs. FECN/BECN mode will set the FECN bit in outbound frames and set BECN bit for inbound frames leaving flow control up to the DTE devices. |
| adTSUIQPvcConfig | 1.3.6.1.4.1.664.2.147.4 | |||
| adTSUIQPvcConfigTable | 1.3.6.1.4.1.664.2.147.4.1 | not-accessible | n/a. | |
| adTSUIQPvcConfigEntry | 1.3.6.1.4.1.664.2.147.4.1.1 | not-accessible | n/a | |
| INT adTSUIQPvcConfigIndex | 1.3.6.1.4.1.664.2.147.4.1.1.1 | INTEGER | read-only | n/a. |
| INT adTSUIQPvcDLCI | 1.3.6.1.4.1.664.2.147.4.1.1.2 | INTEGER | read-write | Address for this PVC entry. (Range 16 - 1007). |
| INT adTSUIQPvcCIR | 1.3.6.1.4.1.664.2.147.4.1.1.3 | INTEGER | read-write | Commited Information Rate for this PVC in Kbps. (Range 0 - 1536). |
| INT adTSUIQPvcSequenceOption | 1.3.6.1.4.1.664.2.147.4.1.1.4 | INTEGER | read-write | Sequence number allows the IQ to detect lost frames across the frame relay service. This option should be disabled for PVCs that do not have IQ on both ends. |
| INT adTSUIQPvcDelayPacketOption | 1.3.6.1.4.1.664.2.147.4.1.1.5 | INTEGER | read-write | Delay packet option for this PVC allows the IQ to sample round trip delay across the frame relay service. This option should be disabled for PVCs that do not have IQ on both ends. |
| INT adTSUIQPvcDBUDLCI | 1.3.6.1.4.1.664.2.147.4.1.1.6 | INTEGER | read-write | Used when this PVC entry is used for dial backup. This value should contain the PVC address as seen on the far end of the PVC. |
| INT adTSUIQPvcStatsControl | 1.3.6.1.4.1.664.2.147.4.1.1.7 | INTEGER | read-write | Stats Control option determines how the IQ will track statistics for this PVC entry. Auto will allow the IQ to track statistics for a PVC if enough memory is available. |
| adTSUIQCurrentStatus | 1.3.6.1.4.1.664.2.147.5 | |||
| INT adTSUIQT1State | 1.3.6.1.4.1.664.2.147.5.1 | INTEGER | read-only | Current status of the T1 interface |
| INT adTSUIQDteControlLeads | 1.3.6.1.4.1.664.2.147.5.2 | INTEGER | read-only | This bit map integer reflects the current state of the DTE control leads as follows: bit meaning 0 CTS 1 RTS 2 DSR 3 DTR 4 DCD A 1 means the lead is on. |
| INT adTSUIQDBUPortType | 1.3.6.1.4.1.664.2.147.5.3 | INTEGER | read-only | Returns the DBU card type installed. |
| INT adTSUIQLANPortStatus | 1.3.6.1.4.1.664.2.147.5.4 | INTEGER | read-only | Returns the LAN card type installed. |
| INT adTSUIQLEDstatus | 1.3.6.1.4.1.664.2.147.5.5 | INTEGER | read-only | This bit map integer reflects TSUIQ front panel LED state as follows: bit meaning 0 TEST 1 ALARM 2 ERROR 3 RD 4 TD 5 CTS 6 RTS |
| INT adTSUIQDTESignalingState | 1.3.6.1.4.1.664.2.147.5.6 | INTEGER | read-only | Current state of the PVC signaling between the TSUIQ and the attached frame relay dte. |
| INT adTSUIQNETSignalingState | 1.3.6.1.4.1.664.2.147.5.7 | INTEGER | read-only | Current state of the PVC signaling between the TSUIQ and the frame relay service. |
| INT adTSUIQNETPVCCount | 1.3.6.1.4.1.664.2.147.5.8 | INTEGER | read-only | Current count of network pvcs. |
| INT adTSUIQNETPVCConfigTableSize | 1.3.6.1.4.1.664.2.147.5.9 | INTEGER | read-only | Current count of rows in the PVC config table. |
| INT adTSUIQDBUState | 1.3.6.1.4.1.664.2.147.5.10 | INTEGER | read-only | Current state of the DBU interface. |
| adTSUIQIntT1Status | 1.3.6.1.4.1.664.2.147.6 | |||
| adTSUIQIntT1StatusTable | 1.3.6.1.4.1.664.2.147.6.1 | not-accessible | n/a. | |
| adTSUIQIntT1StatusEntry | 1.3.6.1.4.1.664.2.147.6.1.1 | not-accessible | n/a | |
| INT adTSUIQIntT1SlotIndex | 1.3.6.1.4.1.664.2.147.6.1.1.1 | INTEGER | read-only | n/a. |
| CTR adTSUIQIntT1UnavailableTime | 1.3.6.1.4.1.664.2.147.6.1.1.2 | Counter | read-only | Amount of time in seconds the T1 port is unavailable due to test or in an inactive state. |
| CTR adTSUIQIntT1StateChange | 1.3.6.1.4.1.664.2.147.6.1.1.3 | Counter | read-only | Number of changes in the T1 port state. This includes all normal, inactive, and test state transitions. |
| INT adTSUIQIntT1SignalLossEvent | 1.3.6.1.4.1.664.2.147.6.1.1.4 | INTEGER | read-only | Active state represents one or more signal loss events. |
| INT adTSUIQIntT1LoopBackEvent | 1.3.6.1.4.1.664.2.147.6.1.1.5 | INTEGER | read-only | Active state represents one or more loopback events. |
| INT adTSUIQIntT1AISEvent | 1.3.6.1.4.1.664.2.147.6.1.1.6 | INTEGER | read-only | Active state represents one or more AIS events. AIS is triggered by unframed all ones condition from the T1 service provider. |
| INT adTSUIQIntT1RedAlarmEvent | 1.3.6.1.4.1.664.2.147.6.1.1.7 | INTEGER | read-only | Active state represents one or more red alarm events. Red alarm is triggered by loss of frame alignment on the receive T1 signal. |
| INT adTSUIQIntT1YellowAlarmEvent | 1.3.6.1.4.1.664.2.147.6.1.1.8 | INTEGER | read-only | Active state represents one or more yellow alarm events. Yellow alarm is an indication the service provider has lost frame alignmnet. |
| INT adTSUIQIntT1PLLAlarmEvent | 1.3.6.1.4.1.664.2.147.6.1.1.9 | INTEGER | read-only | Active state represents one or more PLL alarm events. PLL alarm is an indication that the transmit and receive side of the T1 interface are not looped timed. This will occur when both ends of the T1 are set to provide timing. |
| CTR adTSUIQIntT1PathCodeViolation | 1.3.6.1.4.1.664.2.147.6.1.1.10 | Counter | read-only | Count of path code violations received. Path code violations are a errors in the frame bit postions for D4 and ESF CRC errors when set for ESF. |
| CTR adTSUIQIntT1LineCodeViolation | 1.3.6.1.4.1.664.2.147.6.1.1.11 | Counter | read-only | Count of line code violations received. Line code violations are a combination of BPVs that are not part of B8ZS code and excess zeros. Excess zeros are 8 or more consecutive zeros when set for B8ZS and 15 or more consecutive zeros when set for AMI. |
| adTSUIQDayT1Status | 1.3.6.1.4.1.664.2.147.7 | |||
| adTSUIQDayT1StatusTable | 1.3.6.1.4.1.664.2.147.7.1 | not-accessible | n/a. | |
| adTSUIQDayT1StatusEntry | 1.3.6.1.4.1.664.2.147.7.1.1 | not-accessible | n/a | |
| INT adTSUIQDayT1SlotIndex | 1.3.6.1.4.1.664.2.147.7.1.1.1 | INTEGER | read-only | n/a. |
| CTR adTSUIQDayT1UnavailableTime | 1.3.6.1.4.1.664.2.147.7.1.1.2 | Counter | read-only | Amount of time in seconds the T1 port is unavailable due to test or in an inactive state. |
| CTR adTSUIQDayT1StateChange | 1.3.6.1.4.1.664.2.147.7.1.1.3 | Counter | read-only | Number of changes in the T1 port state. This includes all normal, inactive, and test state transitions. |
| INT adTSUIQDayT1SignalLossEvent | 1.3.6.1.4.1.664.2.147.7.1.1.4 | INTEGER | read-only | Active state represents one or more signal loss events. |
| INT adTSUIQDayT1LoopBackEvent | 1.3.6.1.4.1.664.2.147.7.1.1.5 | INTEGER | read-only | Active state represents one or more loopback events. |
| INT adTSUIQDayT1AISEvent | 1.3.6.1.4.1.664.2.147.7.1.1.6 | INTEGER | read-only | Active state represents one or more AIS events. AIS is triggered by unframed all ones condition from the T1 service provider. |
| INT adTSUIQDayT1RedAlarmEvent | 1.3.6.1.4.1.664.2.147.7.1.1.7 | INTEGER | read-only | Active state represents one or more red alarm events. Red alarm is triggered by loss of frame alignment on the receive T1 signal. |
| INT adTSUIQDayT1YellowAlarmEvent | 1.3.6.1.4.1.664.2.147.7.1.1.8 | INTEGER | read-only | Active state represents one or more yellow alarm events. Yellow alarm is an indication the service provider has lost frame alignmnet. |
| INT adTSUIQDayT1PLLAlarmEvent | 1.3.6.1.4.1.664.2.147.7.1.1.9 | INTEGER | read-only | Active state represents one or more PLL alarm events. PLL alarm is an indication that the transmit and receive side of the T1 interface are not looped timed. This will occur when both ends of the T1 are set to provide timing. |
| CTR adTSUIQDayT1PathCodeViolation | 1.3.6.1.4.1.664.2.147.7.1.1.10 | Counter | read-only | Count of path code violations received. Path code violations are a errors in the frame bit postions for D4 and ESF CRC errors when set for ESF. |
| CTR adTSUIQDayT1LineCodeViolation | 1.3.6.1.4.1.664.2.147.7.1.1.11 | Counter | read-only | Count of line code violations received. Line code violations are a combination of BPVs that are not part of B8ZS code and excess zeros. Excess zeros are 8 or more consecutive zeros when set for B8ZS and 15 or more consecutive zeros when set for AMI. |
| adTSUIQDiagnostic | 1.3.6.1.4.1.664.2.147.8 | |||
| adTSUIQDiagnosticTable | 1.3.6.1.4.1.664.2.147.8.1 | not-accessible | n/a. | |
| adTSUIQDiagnosticEntry | 1.3.6.1.4.1.664.2.147.8.1.1 | not-accessible | n/a | |
| INT adTSUIQDiagnosticIndex | 1.3.6.1.4.1.664.2.147.8.1.1.1 | INTEGER | read-only | n/a. |
| INT adTSUIQDiagnosticDlci | 1.3.6.1.4.1.664.2.147.8.1.1.2 | INTEGER | read-only | Sets the DLCI for PVC Loopback. (Range 16 - 1007). |
| INT adTSUIQDiagnosticControl | 1.3.6.1.4.1.664.2.147.8.1.1.3 | INTEGER | read-write | Starts or Stops the PVC Loopback Test. |
| INT adTSUIQDiagnosticDuration | 1.3.6.1.4.1.664.2.147.8.1.1.4 | INTEGER | read-write | Test duration in seconds. |
| INT adTSUIQDiagnosticStatus | 1.3.6.1.4.1.664.2.147.8.1.1.5 | INTEGER | read-write | PVC Loopback Test Status. (Active/Inactive). |
| INT adTSUIQDiagnosticSecondsRemaining | 1.3.6.1.4.1.664.2.147.8.1.1.6 | INTEGER | read-only | PVC Loopback Test time remaining in seconds. |
| CTR adTSUIQDiagnosticFramesTx | 1.3.6.1.4.1.664.2.147.8.1.1.7 | Counter | read-only | Diagnostic Frames transmitted. |
| CTR adTSUIQDiagnosticFramesRx | 1.3.6.1.4.1.664.2.147.8.1.1.8 | Counter | read-only | Diagnostic Frames received. |
| CTR adTSUIQDiagnosticLostFrames | 1.3.6.1.4.1.664.2.147.8.1.1.9 | Counter | read-only | Diagnostic Frames Lost. |
| GAU adTSUIQDiagnosticMaxDelay | 1.3.6.1.4.1.664.2.147.8.1.1.10 | Gauge | read-only | Diagnostic Maximum Delay measurement. |
| GAU adTSUIQDiagnosticMinDelay | 1.3.6.1.4.1.664.2.147.8.1.1.11 | Gauge | read-only | Diagnostic Minimum Delay measurement. |
| GAU adTSUIQDiagnosticAvgDelay | 1.3.6.1.4.1.664.2.147.8.1.1.12 | Gauge | read-only | Diagnostic Average Delay measurement. |
| adTSUIQ1406Time | 1.3.6.1.4.1.664.2.147.9 | |||
| adTSUIQ1406TimeTable | 1.3.6.1.4.1.664.2.147.9.1 | not-accessible | n/a. | |
| adTSUIQ1406TimeEntry | 1.3.6.1.4.1.664.2.147.9.1.1 | not-accessible | n/a | |
| INT adTSUIQ1406TimeSlotIndex | 1.3.6.1.4.1.664.2.147.9.1.1.1 | INTEGER | read-only | n/a. |
| STR adTSUIQ1406TimeStamp | 1.3.6.1.4.1.664.2.147.9.1.1.2 | DisplayString | read-only | Time interval started. Format H:M if not midnight else M-D |
| adTSUIQDBUConfig | 1.3.6.1.4.1.664.2.147.10 | |||
| INT adTSUIQDBUOption | 1.3.6.1.4.1.664.2.147.10.1 | INTEGER | read-write | This option specifies whether the unit automatically enters dial backup mode or waits for manual setup. |
| INT adTSUIQDBUStartLockout | 1.3.6.1.4.1.664.2.147.10.2 | INTEGER | read-write | This option selects the hour to begin disabling dial backup operation when daily or weekend lockout mode is active. |
| INT adTSUIQDBUEndLockout | 1.3.6.1.4.1.664.2.147.10.3 | INTEGER | read-write | This option selects the hour to end dial backup lockout when daily or weekend lockout mode is active. |
| INT adTSUIQDBUMode | 1.3.6.1.4.1.664.2.147.10.4 | INTEGER | read-write | This option specifies the dial backup operating mode for the unit as orginate or answer. One end must be set to originate and the other end to answer. |
| INT adTSUIQDBUWithNetworkFailure | 1.3.6.1.4.1.664.2.147.10.5 | INTEGER | read-write | This option enables the unit to enter backup mode when T1 network failure occurs. |
| INT adTSUIQDBUNoLMI | 1.3.6.1.4.1.664.2.147.10.6 | INTEGER | read-write | This option enables the unit to enter backup mode when network PVC signaling state goes down. |
| INT adTSUIQAutoRestoreTimer | 1.3.6.1.4.1.664.2.147.10.7 | INTEGER | read-write | This option selects the amount of time that the TSUIQ circuit must be active before the unit switches from backup to normal mode of operation. The timer value is in minutes from 0 to 60. A zero value disables automatic restore, TSUIQ operation must be restored manually. |
| INT adTSUIQRedialCount | 1.3.6.1.4.1.664.2.147.10.8 | INTEGER | read-write | This option allows the selection of the number of times the unit will redial the Far End unit when attempting to go to backup and a busy or reorder condition occurs. Redial count can be set for a maximum of 60. |
| INT adTSUIQDBUFailTimeout | 1.3.6.1.4.1.664.2.147.10.9 | INTEGER | read-write | This option allows the selection of the amount of time that the dedicated circuit failure condition is active before attempting to enter dial backup mode. The Fail Timeout value is in increments of 10 seconds up to a maximum of 600 seconds. |
| INT adTSUIQDBURedialTimer | 1.3.6.1.4.1.664.2.147.10.10 | INTEGER | read-write | This option works in conjunction with the Redial Counter option. The Redial Timer specifies the amount of time between redial attempts. The Redial Timer value is seconds, up to a maximum of 60 seconds. |
| INT adTSUIQDBUPassCheck | 1.3.6.1.4.1.664.2.147.10.11 | INTEGER | read-write | This option allows the unit to send and verify a dial backup passcode for an additional level of security. When enabled, the originate unit sends the passcode and the answer unit checks the passcode before the backup connection is considered valid. |
| STR adTSUIQDBUPassCode | 1.3.6.1.4.1.664.2.147.10.12 | DisplayString | read-write | This option sets the dial backup passcode used to provide an additional level of security. A passcode of one to ten digit characters can be set. If enabled, the originate unit sends the passcode and the answer unit checks the passcode to verify the connection. |
| INT adTSUIQWeekendLockout | 1.3.6.1.4.1.664.2.147.10.13 | INTEGER | read-write | This option enables or disables Weekend Lockout for Dial Backup operation. If enabled, no backup will occur from midnight Friday to midnight Sunday. |
| INT adTSUIQDailyLockout | 1.3.6.1.4.1.664.2.147.10.14 | INTEGER | read-write | This option enables or disables Daily Lockout for Dial Backup operation. If enabled, no backup will occur between Lockout Start hour and Lockout End hour. |
| INT adTSUIQAnswerAlways | 1.3.6.1.4.1.664.2.147.10.15 | INTEGER | read-write | This option enables or disables Answer Always for Dial Backup operation. If enabled, the answer unit answers any incoming call regardless of failed conditions. |
| INT adTSUIQBeeperOption | 1.3.6.1.4.1.664.2.147.10.16 | INTEGER | read-write | This option enables or disables the audible alarm when the IQ unit goes into dial backup mode. |
| STR adTSUIQDBUPhoneNumber1 | 1.3.6.1.4.1.664.2.147.10.17 | DisplayString | read-write | This option is used to set a phone number to place a DBU call. |
| STR adTSUIQDBUPhoneNumber2 | 1.3.6.1.4.1.664.2.147.10.18 | DisplayString | read-write | This option is used to set a phone number to place a DBU call. |
| STR adTSUIQDBUPhoneNumber3 | 1.3.6.1.4.1.664.2.147.10.19 | DisplayString | read-write | This option is used to set a phone number to place a DBU call. |
| STR adTSUIQDBUPhoneNumber4 | 1.3.6.1.4.1.664.2.147.10.20 | DisplayString | read-write | This option is used to set a phone number to place a DBU call. |
| STR adTSUIQDBUPhoneNumber5 | 1.3.6.1.4.1.664.2.147.10.21 | DisplayString | read-write | This option is used to set a phone number to place a DBU call. |
| INT adTSUIQDBUISDNSwitch | 1.3.6.1.4.1.664.2.147.10.22 | INTEGER | read-write | This option is used to select the ISDN switch type. |
| INT adTSUIQDBUISDNBChannelRate | 1.3.6.1.4.1.664.2.147.10.23 | INTEGER | read-write | This option is used to select the ISDN channel rate. |
| INT adTSUIQDBUISDNBChannelCount | 1.3.6.1.4.1.664.2.147.10.24 | INTEGER | read-write | This option is used to select the number ISDN channels to use. |
| STR adTSUIQDBUISDNSPID1 | 1.3.6.1.4.1.664.2.147.10.25 | DisplayString | read-write | This option is used to set the SPID for the ISDN interface. |
| STR adTSUIQDBUISDNSPID2 | 1.3.6.1.4.1.664.2.147.10.26 | DisplayString | read-write | This option is used to set the SPID for the ISDN interface. |
| STR adTSUIQDBUISDNLDN1 | 1.3.6.1.4.1.664.2.147.10.27 | DisplayString | read-write | This option is used to set LDN for the ISDN interface. |
| STR adTSUIQDBUISDNLDN2 | 1.3.6.1.4.1.664.2.147.10.28 | DisplayString | read-write | This option is used to set LDN for the ISDN interface. |
| INT adTSUIQV34LineType | 1.3.6.1.4.1.664.2.147.10.29 | INTEGER | read-write | This option selects the type of analog phone line. |
| INT adTSUIQDCEInterfaceType | 1.3.6.1.4.1.664.2.147.10.30 | INTEGER | read-write | This option enables or disables Answer Always for Dial Backup operation. If enabled, the answer unit answers any incoming call regardless of failed conditions. |
| INT adTSUIQDCEBitRate | 1.3.6.1.4.1.664.2.147.10.31 | INTEGER | read-write | This option is uses for utilization measurement of the DBU port when an external DCE device is used. Set this parameter in KBPS close to the connection rate. |
| adTSUIQIntDBUStatus | 1.3.6.1.4.1.664.2.147.11 | |||
| adTSUIQIntDBUStatusTable | 1.3.6.1.4.1.664.2.147.11.1 | not-accessible | n/a. | |
| adTSUIQIntDBUStatusEntry | 1.3.6.1.4.1.664.2.147.11.1.1 | not-accessible | n/a | |
| INT adTSUIQIntDBUSlotIndex | 1.3.6.1.4.1.664.2.147.11.1.1.1 | INTEGER | read-only | n/a. |
| CTR adTSUIQIntDBUFramesRx | 1.3.6.1.4.1.664.2.147.11.1.1.2 | Counter | read-only | The number of Frames the Port received for the interval. |
| CTR adTSUIQIntDBUFramesTx | 1.3.6.1.4.1.664.2.147.11.1.1.3 | Counter | read-only | The number of Frames the Port transmitted for the interval. |
| CTR adTSUIQIntDBUBytesRx | 1.3.6.1.4.1.664.2.147.11.1.1.4 | Counter | read-only | The number of Bytes the Port received for the interval. |
| CTR adTSUIQIntDBUBytesTx | 1.3.6.1.4.1.664.2.147.11.1.1.5 | Counter | read-only | The number of Bytes the Port transmitted for the interval. |
| GAU adTSUIQIntDBUAvgThruputTx | 1.3.6.1.4.1.664.2.147.11.1.1.6 | Gauge | read-only | The Average Throughput the Port transmitted for the interval. |
| GAU adTSUIQIntDBUAvgThruputRx | 1.3.6.1.4.1.664.2.147.11.1.1.7 | Gauge | read-only | The Average Throughput the Port received for the interval. |
| CTR adTSUIQIntDBUMaxThruputTx | 1.3.6.1.4.1.664.2.147.11.1.1.8 | Counter | read-only | The Maximum Throughput the Port transmitted for the interval. |
| CTR adTSUIQIntDBUMaxThruputRx | 1.3.6.1.4.1.664.2.147.11.1.1.9 | Counter | read-only | The Maximum Throughput the Port received for the interval. |
| GAU adTSUIQIntDBUAvgUtilizationTx | 1.3.6.1.4.1.664.2.147.11.1.1.10 | Gauge | read-only | The Average Utilization the Port transmitted for the interval. |
| GAU adTSUIQIntDBUAvgUtilizationRx | 1.3.6.1.4.1.664.2.147.11.1.1.11 | Gauge | read-only | The Average Utilization the Port received for the interval. |
| CTR adTSUIQIntDBUMaxUtilizationTx | 1.3.6.1.4.1.664.2.147.11.1.1.12 | Counter | read-only | The Maximum Utilization the Port transmitted for the interval. |
| CTR adTSUIQIntDBUMaxUtilizationRx | 1.3.6.1.4.1.664.2.147.11.1.1.13 | Counter | read-only | The Maximum Utilization the Port received for the interval. |
| CTR adTSUIQIntTimeInDBU | 1.3.6.1.4.1.664.2.147.11.1.1.14 | Counter | read-only | Time in seconds the DBU port was active. |
| CTR adTSUIQIntDBUCrcErrors | 1.3.6.1.4.1.664.2.147.11.1.1.15 | Counter | read-only | Number of frames received with CRC errors. |
| CTR adTSUIQIntDBUAbortFrames | 1.3.6.1.4.1.664.2.147.11.1.1.16 | Counter | read-only | Number of frames received without proper flag termination. |
| CTR adTSUIQIntDBUOctectViolations | 1.3.6.1.4.1.664.2.147.11.1.1.17 | Counter | read-only | Number of frames received with a bit count not divisible by eigth. |
| CTR adTSUIQIntDBUDiscardFrames | 1.3.6.1.4.1.664.2.147.11.1.1.18 | Counter | read-only | Number of frames discarded by the IQ unit |
| CTR adTSUIQIntDBULengthErrors | 1.3.6.1.4.1.664.2.147.11.1.1.19 | Counter | read-only | Number of frames received that is less than 5 bytes or greater than 4500 bytes. |
| CTR adTSUIQIntDBUEncapsulationErrors | 1.3.6.1.4.1.664.2.147.11.1.1.20 | Counter | read-only | Number of frames destined for the IQ IP stack with that does not meet the FRF.3 IA. |
| CTR adTSUIQIntDBUUnroutable | 1.3.6.1.4.1.664.2.147.11.1.1.21 | Counter | read-only | Number of frames received on a management DLCI destined for the IQ unit and have the wrong IP address. |
| adTSUIQDayDBUStatus | 1.3.6.1.4.1.664.2.147.12 | |||
| adTSUIQDayDBUStatusTable | 1.3.6.1.4.1.664.2.147.12.1 | not-accessible | n/a. | |
| adTSUIQDayDBUStatusEntry | 1.3.6.1.4.1.664.2.147.12.1.1 | not-accessible | n/a | |
| INT adTSUIQDayDBUSlotIndex | 1.3.6.1.4.1.664.2.147.12.1.1.1 | INTEGER | read-only | n/a. |
| CTR adTSUIQDayDBUFramesRx | 1.3.6.1.4.1.664.2.147.12.1.1.2 | Counter | read-only | The number of Frames the Port received for the interval. |
| CTR adTSUIQDayDBUFramesTx | 1.3.6.1.4.1.664.2.147.12.1.1.3 | Counter | read-only | The number of Frames the Port transmitted for the interval. |
| CTR adTSUIQDayDBUBytesRx | 1.3.6.1.4.1.664.2.147.12.1.1.4 | Counter | read-only | The number of Bytes the Port received for the interval. |
| CTR adTSUIQDayDBUBytesTx | 1.3.6.1.4.1.664.2.147.12.1.1.5 | Counter | read-only | The number of Bytes the Port transmitted for the interval. |
| GAU adTSUIQDayDBUAvgThruputTx | 1.3.6.1.4.1.664.2.147.12.1.1.6 | Gauge | read-only | The Average Throughput the Port transmitted for the interval. |
| GAU adTSUIQDayDBUAvgThruputRx | 1.3.6.1.4.1.664.2.147.12.1.1.7 | Gauge | read-only | The Average Throughput the Port received for the interval. |
| CTR adTSUIQDayDBUMaxThruputTx | 1.3.6.1.4.1.664.2.147.12.1.1.8 | Counter | read-only | The Maximum Throughput the Port transmitted for the interval. |
| CTR adTSUIQDayDBUMaxThruputRx | 1.3.6.1.4.1.664.2.147.12.1.1.9 | Counter | read-only | The Maximum Throughput the Port received for the interval. |
| GAU adTSUIQDayDBUAvgUtilizationTx | 1.3.6.1.4.1.664.2.147.12.1.1.10 | Gauge | read-only | The Average Utilization the Port transmitted for the interval. |
| GAU adTSUIQDayDBUAvgUtilizationRx | 1.3.6.1.4.1.664.2.147.12.1.1.11 | Gauge | read-only | The Average Utilization the Port received for the interval. |
| CTR adTSUIQDayDBUMaxUtilizationTx | 1.3.6.1.4.1.664.2.147.12.1.1.12 | Counter | read-only | The Maximum Utilization the Port transmitted for the interval. |
| CTR adTSUIQDayDBUMaxUtilizationRx | 1.3.6.1.4.1.664.2.147.12.1.1.13 | Counter | read-only | The Maximum Utilization the Port received for the interval. |
| CTR adTSUIQDayTimeInDBU | 1.3.6.1.4.1.664.2.147.12.1.1.14 | Counter | read-only | Time in seconds the DBU port was active. |
| CTR adTSUIQDayDBUCrcErrors | 1.3.6.1.4.1.664.2.147.12.1.1.15 | Counter | read-only | Number of frames received with CRC errors. |
| CTR adTSUIQDayDBUAbortFrames | 1.3.6.1.4.1.664.2.147.12.1.1.16 | Counter | read-only | Number of frames received without proper flag termination. |
| CTR adTSUIQDayDBUOctectViolations | 1.3.6.1.4.1.664.2.147.12.1.1.17 | Counter | read-only | Number of frames received with a bit count not divisible by eigth. |
| CTR adTSUIQDayDBUDiscardFrames | 1.3.6.1.4.1.664.2.147.12.1.1.18 | Counter | read-only | Number of frames discarded by the IQ unit |
| CTR adTSUIQDayDBULengthErrors | 1.3.6.1.4.1.664.2.147.12.1.1.19 | Counter | read-only | Number of frames received that is less than 5 bytes or greater than 4500 bytes. |
| CTR adTSUIQDayDBUEncapsulationErrors | 1.3.6.1.4.1.664.2.147.12.1.1.20 | Counter | read-only | Number of frames destined for the IQ IP stack with that does not meet the FRF.3 IA. |
| CTR adTSUIQDayDBUUnroutable | 1.3.6.1.4.1.664.2.147.12.1.1.21 | Counter | read-only | Number of frames received on a management DLCI destined for the IQ unit and have the wrong IP address. |
| adTSUIQTrapManager | 1.3.6.1.4.1.664.2.147.13 | |||
| adTSUIQTrapManagerTable | 1.3.6.1.4.1.664.2.147.13.1 | not-accessible | The trap manger route table. | |
| adTSUIQTrapManagerEntry | 1.3.6.1.4.1.664.2.147.13.1.1 | not-accessible | n/a | |
| INT adTSUIQTrapManagerRouteIndex | 1.3.6.1.4.1.664.2.147.13.1.1.1 | INTEGER | read-only | n/a. |
| IP adTSUIQTrapManagerRouteIPAddress | 1.3.6.1.4.1.664.2.147.13.1.1.2 | IpAddress | read-write | Sets the Trap Manager IP Address. |
| INT adTSUIQTrapManagerRouteDLCI | 1.3.6.1.4.1.664.2.147.13.1.1.3 | INTEGER | read-write | Sets the Trap Manager DLCI. (Range 16 - 1007). |
| INT adTSUIQTrapManagerRoutePort | 1.3.6.1.4.1.664.2.147.13.1.1.4 | INTEGER | read-write | Selects the Trap Manager Port. |
RFC description
ADTRAN TSUIQ system configuration and monitoring including network ports, DTE ports, PVCs, T1 status, and diagnostics.