EdgeSwitch-ROUTING6-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › EdgeSwitch-ROUTING6-MIB

Organization: Broadcom Inc

Last Updated: 2011-01-26

Category: Technology: IPv6, Vendor: EdgeSwitch/Ubiquiti

Description: Ubiquiti EdgeSwitch IPv6 routing MIB for managing IPv6 static routes, router advertisements, and IPv6 forwarding.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is EdgeSwitch-ROUTING6-MIB?

EdgeSwitch-ROUTING6-MIB is a private Ubiquiti Networks MIB module for the FastPath-based EdgeSwitch line, covering IPv6 routing functionality. It exposes configuration and state for IPv6 static routes, router advertisement (RA) parameters, and IPv6 forwarding behavior on the switch. Rather than hardware health, its monitoring value is mainly in software/protocol status: whether IPv6 forwarding is enabled, whether the route table matches the intended design, and whether router advertisements are being sent as configured, which helps detect misconfigured or stalled IPv6 routing. It builds on the FastPath routing MIB conventions common across Broadcom-based switch silicon and is typically used alongside the standard IP-MIB and IPv6 MIBs rather than in isolation. It is deployed on Ubiquiti EdgeSwitch and EdgeMax devices in SMB and prosumer networks running dual-stack IPv4/IPv6, where the EdgeSwitch-ROUTING6-MIB MIB exposes IPv6 routing state via SNMP.

IPNetwork Monitor allows you to monitor SNMP objects defined in EdgeSwitch-ROUTING6-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Ubiquiti EdgeSwitch
  • Ubiquiti EdgeMax network switch

Monitoring Examples

No sample objects were provided for this module in the source, so specific object or table names cannot be confirmed here. In practice a MIB of this kind would be expected to expose an IPv6 static route table and RA configuration objects, and an administrator would poll them to confirm that configured routes are active and that RA intervals match the intended network design. An anomaly such as a missing expected route or an unexpectedly disabled forwarding flag would indicate a configuration drift or a routing failure.

What Can Be Monitored

  • IPv6 static route configuration
  • IPv6 forwarding enable state
  • router advertisement configuration
  • IPv6 routing table status
Imported Objects

From EdgeSwitch-REF-MIB

fastPathOBJECT-IDENTITY

From IPV6-TC

Ipv6Address
Ipv6AddressIfIdentifier
Ipv6AddressPrefix
Ipv6IfIndex
Ipv6IfIndexOrZero

From SNMPv2-CONF

MODULE-COMPLIANCE
NOTIFICATION-GROUP
OBJECT-GROUP

From SNMPv2-SMI

Counter32
Gauge32
Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
Unsigned32

From SNMPv2-TC

DisplayString
MacAddress
PhysAddress
RowPointer
RowStatus
TimeStamp
TruthValue
VariablePointer

How to Use in IPNetwork Monitor

Example using agentIpv6RouteAdds OID:

Select an Ubiquiti EdgeSwitch (Broadcom FastPath-based) switch (IPv6 routing/RA config) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type agentIpv6RouteAdds into the Find box to locate it in the OID tree, then select it and click OK. The number of routes added to the IPv6 routing table. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

IPv6 unicast routing configuration and monitoring for EdgeSwitch, managing IPv6 interfaces and routing tables.

Start monitoring Ubiquiti EdgeSwitch (Broadcom FastPath-based) switch (IPv6 routing/RA config) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download EdgeSwitch-ROUTING6-MIB