| OID symbolic | OID numeric | Type | Access | Description |
| dnxHDS3 | 1.3.6.1.4.1.644.2.4.2.2 | | | |
| dnxHDS3Enterprise | 1.3.6.1.4.1.644.2.4.2.2.0 | | | ERI DNX HDS3 Enterprise for Alarms/Events |
| eriDNXHybridDS3MIB | 1.3.6.1.4.1.644.3.5 | | | The ERI Enterprise MIB Module for the DNX HDS3 Device. |
| LIN hds3CmdStatus | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.26 | LinkCmdStatus | read-write | The command status for this link configuration row/record.
The value used in a SET will be replaced by a response
value in the GET RESPONSE indicating success or failure.
Default Response State used in GET RESPONSE Command
ready-for-command (0)
initial default status for a row
HDS3 Link Commands used in SET Command (1..199)
update-link-config(1),
Change existing Link Configuration
Response States used in GET RESPONSE Command (200..399)
update-successful (201)
Link data has been successfully changed
HDS3 Port Config Error Codes used in GET RESPONSE Command (400..699)
err-general-link-config-error (400)
Unknown link configuration error occurred
err-invalid-link-status (401)
Unrecognized link status setting
err-invalid-link-framing (402)
Line framing type not valid for link type
err-invalid-link-command (403)
Unrecognized link command-action
err-invalid-link-op-mode (407)
Configured M13 Op mode not valid for port; verify other
link parameters match desired new mode
err-invalid-link-rem-loop (408)
Remote Loop type not valid for hds3 frame type
err-invalid-link-ais (409)
Unrecognized hds3 AIS selection
err-data-locked-by-another-user (450)
Another administrative user is making changes to this
part of the system via a terminal session. Check Event
Log for user name. |
| hds3Config | 1.3.6.1.4.1.644.2.4.2.2.1 | | | |
| hds3Diag | 1.3.6.1.4.1.644.2.4.2.2.2 | | | |
| DS2 hds3DS2Group1 | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.19 | DS2GroupType | read-write | Indicates the type of grouping option used to on links 1 through 4.
Using the VT 2.0, link 4 is not used. |
| DS2 hds3DS2Group2 | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.20 | DS2GroupType | read-write | Indicates the type of grouping option used to on links 5 through 8.
Using the VT 2.0, link 8 is not used. |
| DS2 hds3DS2Group3 | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.21 | DS2GroupType | read-write | Indicates the type of grouping option used to on links 9 through 12.
Using the VT 2.0, link 12 is not used. |
| DS2 hds3DS2Group4 | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.22 | DS2GroupType | read-write | Indicates the type of grouping option used to on links 13 through 16.
Using the VT 2.0, link 16 is not used. |
| DS2 hds3DS2Group5 | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.23 | DS2GroupType | read-write | Indicates the type of grouping option used to on links 17 through 20.
Using the VT 2.0, link 20 is not used. |
| DS2 hds3DS2Group6 | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.24 | DS2GroupType | read-write | Indicates the type of grouping option used to on links 21 through 24.
Using the VT 2.0, link 24 is not used. |
| DS2 hds3DS2Group7 | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.25 | DS2GroupType | read-write | Indicates the type of grouping option used to on links 25 through 28.
Using the VT 2.0, link 28 is not used. |
| STR hds3EquipmentId | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.5 | DisplayString | read-write | This is a description of the equipment in use. |
| STR hds3FacilityId | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.4 | DisplayString | read-write | This is a description of the facility where this equipment
is located. |
| FUN hds3FEACLoopbackReq | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.15 | FunctionSwitch | read-write | Select enabled(1) to allow the module to respond to a Far End
Alarm and Control loopback request. |
| STR hds3FrameId | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.7 | DisplayString | read-write | This is the description of the building where this equipment is
located. |
| ADR hds3FramerStatusAddr | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.1 | LinkPortAddress | read-only | This number uniquely identifies a HDS-3 Framer resource.
This number will be used throughout the system to identify
a unique resource. |
| C32 hds3FramerStatusAISErrSecs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.7 | Counter32 | read-only | This is the number of seconds a Alarm Indication Signal condition was declared.
Declared after optioned AIS pattern is detected for more than 13.5msec. |
| C32 hds3FramerStatusCbitParityErrs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.13 | Counter32 | read-only | The number of C-bit Parity errors detected. |
| C32 hds3FramerStatusCFAErrSecs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.10 | Counter32 | read-only | This is the number of seconds a Frame alignment change was detected. |
| INT hds3FramerStatusCmdStatus | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.19 | INTEGER | read-write | This is the command status for the DS3 Framer Row.
The value used in a SET will be replaced by a response
value in the GET RESPONSE indicating success or failure.
Default Response State used in GET RESPONSE Command
ready-for-command (0)
initial default status for a row
DS3 Framer Action Commands used in SET Command (1..99)
update (1)
Can be used optionally when inserting errors
in order to get status code back in response
clearErrors (14)
Resets all error counters and bert test time to zero
insertError (16)
Inserts the current invalid bit pattern as indicated
by the value of hds3FramerStatusInsErrMode.
Response States used in GET RESPONSE Command (100..199)
update-successful (101)
Action has been successfully performed
clear-successful (114)
Error counts have been successfully cleared
insert-successful (116)
Errored bits have been successfully inserted
The Error Codes used in GET RESPONSE Command (200..799)
err-general-framer-error (200)
Unknown request error occurred.
err-test-in-progress (205)
Requested action cannot be performed during bert
err-field-cannot-be-set (206)
Read-only field was included in SET request
err-invalid-command (208)
Unrecognized framer Command requested
err-snmp-parse-failed (500)
Agent could not parse variable
err-invalid-snmp-type (501)
Variable ASN type does not match Agent defined type
err-invalid-snmp-var-size (502)
Variable size is too big |
| hds3FramerStatusEntry | 1.3.6.1.4.1.644.2.4.2.2.2.1.1 | | not-accessible | The conceptual row of the Framer table.
A row in this table cannot be added or deleted, only modified. |
| C32 hds3FramerStatusExcessZeroErrs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.17 | Counter32 | read-only | The number of Excessive Zero errors detected. |
| C32 hds3FramerStatusFarEndRcvErrSecs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.9 | Counter32 | read-only | This is the number of seconds a Far End Receive Failure condition was declared.
Declared when both X-bits set to 0 in M13 and C-bit Parity frame format
(i.e., yellow alarm indicator) |
| C32 hds3FramerStatusFebeErrs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.14 | Counter32 | read-only | The number of Far End Block errors detected. |
| C32 hds3FramerStatusFramingErrs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.16 | Counter32 | read-only | The number of Framing errors detected. |
| INT hds3FramerStatusInsErrMode | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.18 | INTEGER | read-write | Determines the status of the current Insert Error mode associated
with the framer. In order to insert an error, the hds3FramerStatusCmdStatus
must be sent in a SET PDU with a value of 'insertError'. |
| C32 hds3FramerStatusLCVErrs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.15 | Counter32 | read-only | The number of Line Code Violation errors detected. |
| C32 hds3FramerStatusLOSErrSecs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.5 | Counter32 | read-only | This is the number of seconds a Loss of Signal condition was declared.
Loss of signal declared after receipt of 175 contiguous zeroes. |
| C32 hds3FramerStatusOOFErrSecs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.6 | Counter32 | read-only | This is the number of seconds Frame alignment errors were detected. |
| C32 hds3FramerStatusPbitParityErrs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.12 | Counter32 | read-only | The number of P-bit Parity errors detected. |
| C32 hds3FramerStatusRcvIdleErrSecs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.8 | Counter32 | read-only | This is the number of seconds a Receive Idle Pattern condition was declared.
Declared when DS3 1100 idle pattern detected for more than 13.5ms. |
| C32 hds3FramerStatusRedAlrmErrSecs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.4 | Counter32 | read-only | This is the number of seconds a Red Alarm condition was declared.
Declared when out of frame condition persists for more than 13.5msec. |
| I32 hds3FramerStatusResource | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.2 | Integer32 | read-only | This number uniquely identifies a HDS-3 Framer link resource.
This number is provided as key to allow the manager to map this
entry to a corresponding Resource Table Entry. |
| INT hds3FramerStatusState | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.3 | INTEGER | read-only | Determines the current line condition status of the Framer.
ok (0) - No Alarm
ais (8) - Sending All Ones
lof (32) - Loss/Out of Frame
los (64) - Loss of Signal
errors (2147483647) - Multiple Errors displays raw bit field value |
| hds3FramerStatusTable | 1.3.6.1.4.1.644.2.4.2.2.2.1 | | not-accessible | This is the HDS-3 Framer Status table which consists of a single
entry for each card's Framer Display. The total number of
entries depends on the number of HDS3 cards in the nest. |
| C32 hds3FramerStatusTotErrSecs | 1.3.6.1.4.1.644.2.4.2.2.2.1.1.11 | Counter32 | read-only | Total number of seconds in which any of the errored events have occurred. |
| STR hds3Generator | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.10 | DisplayString | read-write | This is the user description of the number generated by this
equipment. |
| ADR hds3LIUAddr | 1.3.6.1.4.1.644.2.4.2.2.2.2.1.1 | LinkPortAddress | read-only | This number uniquely identifies a HDS-3 LIU resource address.
This number will be used throughout the system to identify
a unique resource. |
| C32 hds3LIUAnalogErrs | 1.3.6.1.4.1.644.2.4.2.2.2.2.1.8 | Counter32 | read-only | This is the number of seconds recorded for the LIU Analog Errors. |
| C32 hds3LIUBertDuration | 1.3.6.1.4.1.644.2.4.2.2.2.2.1.5 | Counter32 | read-only | This is the number of seconds for the LIU Bert Duration. |
| C32 hds3LIUBertErrSecsEx | 1.3.6.1.4.1.644.2.4.2.2.2.2.1.4 | Counter32 | read-only | This is the number of LIU Bert Errored seconds. |
| INT hds3LIUBertState | 1.3.6.1.4.1.644.2.4.2.2.2.2.1.3 | INTEGER | read-write | This is the LIU Bert State indicated by liu-bert(on)/off.
The LIU Bert is an 2^15-1 Unframed BERT. |
| INT hds3LIUCmdStatus | 1.3.6.1.4.1.644.2.4.2.2.2.2.1.12 | INTEGER | read-write | This is the command status for the LIU Framer Row.
The value used in a SET will be replaced by a response
value in the GET RESPONSE indicating success or failure.
Default Response State used in GET RESPONSE Command
ready-for-command (0)
initial default status for a row
Commands used in SET Command (1..99)
update (1)
Can be used optionally when activating loops and berts
in order to get status code back in response
clearErrors (14)
Resets all error counters and bert test time to zero
Response States used in GET RESPONSE Command (100..199)
update-successful (101)
Test action has been successfully performed
clear-successful (114)
Error counts have been successfully cleared
Error Codes used in GET RESPONSE Command (200..799)
err-general-liu-error (200)
Unknown LIU request error occurred.
err-invalid-loop-type (202)
Unrecognized loop selection
err-invalid-bert-type (203)
Unrecognized bert selection
err-test-in-progress (205)
Requested action cannot be performed during bert
err-field-cannot-be-set (206)
Read-only field was included in SET request
err-invalid-command (208)
Unrecognized Test Command requested
err-snmp-parse-failed (500)
Agent could not parse variable
err-invalid-snmp-type (501)
Variable ASN type does not match Agent defined type
err-invalid-snmp-var-size (502)
Variable size is too big |
| C32 hds3LIUCodingViolationErrs | 1.3.6.1.4.1.644.2.4.2.2.2.2.1.10 | Counter32 | read-only | This is the total number of Errored Seconds for the LIU Coding Violation. |
| C32 hds3LIUDigitalErrs | 1.3.6.1.4.1.644.2.4.2.2.2.2.1.7 | Counter32 | read-only | This is the number of seconds recorded for the LIU Digital Errors. |
| hds3LIUEntry | 1.3.6.1.4.1.644.2.4.2.2.2.2.1 | | not-accessible | The conceptual row of the HDS3 LIU table.
A row in this table cannot be added or deleted, only modified. |
| C32 hds3LIUExcessZeroErrs | 1.3.6.1.4.1.644.2.4.2.2.2.2.1.9 | Counter32 | read-only | This is the number of seconds LIU Excess zero errors were detected. |
| INT hds3LIULoopType | 1.3.6.1.4.1.644.2.4.2.2.2.2.1.6 | INTEGER | read-write | Indicates the loopback status of the DS3 Framer/LIU for this device.
off (0) - indicates loopback is disabled
ds3-local (1) - indicates DS3 local data is looped back to itself
ds3-line (36)- entire DS3 Frame is looped, framing is not regenerated
liu (39)- indicates Line Interface Unit local data is looped back
to itself. |
| C32 hds3LIUPRBSCheckErrs | 1.3.6.1.4.1.644.2.4.2.2.2.2.1.11 | Counter32 | read-only | This is the total number of Errored Seconds for the LIU PRBS check. |
| I32 hds3LIUResource | 1.3.6.1.4.1.644.2.4.2.2.2.2.1.2 | Integer32 | read-only | This number uniquely identifies a HDS-3 LIU resource.
This number is provided as a key to allow the manager to map this
entry to a corresponding Resource Table Entry. |
| hds3LIUTable | 1.3.6.1.4.1.644.2.4.2.2.2.2 | | not-accessible | This is the HDS-3 LIU Diagnostic Status Display table which consists
of an entry for each HDS3 card's Line Interface Unit Display. The
number of entries depends on the number of HDS3 cards in the nest. |
| STR hds3Location | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.6 | DisplayString | read-write | This is the user description of the location for this equipment. |
| INT hds3M13OpMode | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.11 | INTEGER | read-write | The framing selection for the DS1 to HDS-3 multiplexing. |
| INT hds3M13RemLoop | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.14 | INTEGER | read-write | Controls line codes used to set and reset DS3 remote line
loopback requests. This setting is provided by the carrier.
These codes cause a DS3 loopback in remote DS3 equipment or
respond to codes from remote DS3 equipment. This applies to
Bellcore M13 mode only. Different manufacturers use different
patterns in M13 mode. |
| ADR hds3PortCfgAddr | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.1 | LinkPortAddress | read-only | This number uniquely identifies a HDS-3 T1/E1 link resource.
This number will be used throughout the system to identify
a unique resource. |
| STR hds3PortCfgName | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.3 | DisplayString | read-write | This is the user friendly text name to identify the circuit. |
| I32 hds3PortCfgResource | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.2 | Integer32 | read-only | Uniquely identifies an HDS3 Port in the system.
This number is provided as key to allow the manager to
map this entry to a corresponding Resource Table entry. |
| hds3PortConfigEntry | 1.3.6.1.4.1.644.2.4.2.2.1.1.1 | | not-accessible | The conceptual row of the HDS-3 Port Configuration table.
A row in this table cannot be added or deleted, only modified. |
| hds3PortConfigTable | 1.3.6.1.4.1.644.2.4.2.2.1.1 | | not-accessible | This is the HDS-3 Port Configuration table which consists
of an entry for each of the HDS-3 cards. The total number of
entries depends on the number of HDS-3 cards in the nest.
This is the HDS-3 DS2/G.747 Configuration table which consists
of an entry for each of the HDS-3 cards. The total number of
entries depends on the number of HDS-3 cards in the nest. |
| NTF hds3PortConfigTrap | 1.3.6.1.4.1.644.2.4.2.2.0.1 | | | This trap is used to notify a NMS that a user has updated
the configuration for a given HDS3 Port entry. |
| STR hds3PortNumber | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.9 | DisplayString | read-write | This is the user description of the HDS-3 port. |
| INT hds3RcvAIS | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.17 | INTEGER | read-write | The Received bit pattern to use to determine when the remote
line is in error. |
| FUN hds3RcvLoopTiming | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.12 | FunctionSwitch | read-write | Enables or disables the HDS-3 transmit timing provided by the
receive clock. When disabled, timing is provided by an on-board
oscillator. |
| DEC hds3ShortCable | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.13 | DecisionType | read-write | Indicates the line build out of the HDS-3 transmitter. 'Yes' when
attached to a cable less than 50 feet long. |
| LIN hds3T1E1CfgCmdStatus | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.12 | LinkCmdStatus | read-write | The command status for this link configuration row/record.
The value used in a SET will be replaced by a response
value in the GET RESPONSE indicating success or failure.
Default Response State used in GET RESPONSE Command
ready-for-command (0)
initial default status for a row
HDS3-T1E1 Link Commands used in SET Command (1..199)
update(1)
Change existing Link Configuration
inServiceAll (7)
Change Link Status to in-service for all 8 links.
copyToAll (9)
Copy T1 Link configuration to all other links
within the same device
outOfServiceAll (12)
Change Link Status to out-of-service for all 8 links.
Response States used in GET RESPONSE Command (100..199)
update-successful (101)
Link data has been successfully changed
insvc-successful (107)
All Links have been successfully placed In Service
copy-successful (109)
T1 Link data has been successfully copied to other links
oos-successful (112)
All Links have been successfully placed Out of Service
HDS3-T1E1 Link Config Error Codes used in GET RESPONSE Command (400..699)
err-general-link-config-error (400)
Unknown link configuration error occurred
err-invalid-link-status (401)
Unrecognized link status setting
err-invalid-link-framing (402)
Line framing type not valid for link type
err-invalid-link-command (403)
Unrecognized link command-action
err-invalid-esf-format (405)
ESF type not applicable to link type
err-invalid-link-density (406)
Unrecognized T1 link density setting
err-invalid-network-loop (410)
Unrecognized network loop setting
err-invalid-yellow-alrm (411)
Unrecognized yellow alarm setting
err-invalid-red-timeout (412)
Unrecognized red alarm timeout
err-invalid-idle-code (413)
Unrecognized idle code
err-device-in-standby (414)
Can't change config for designated Standby device
err-invalid-link-bits (427)
Reserved E1 bits must be left at zero.
err-data-locked-by-another-user (450)
Another administrative user is making changes to this
part of the system via a terminal session. Check Event
Log for user name
err-snmp-parse-failed (500)
Agent could not parse variable
err-invalid-snmp-type (501)
Variable ASN type does not match Agent defined type
err-invalid-snmp-var-size (502)
Variable size is too big |
| ADR hds3T1E1CfgLinkAddr | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.1 | LinkPortAddress | read-only | This number uniquely identifies a HDS-3 T1/E1 link resource.
This number will be used throughout the system to identify
a unique resource. |
| STR hds3T1E1CfgLinkName | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.3 | DisplayString | read-write | This is the user friendly text name to identify the link. |
| I32 hds3T1E1CfgResource | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.2 | Integer32 | read-only | Uniquely identifies an HDS-3 T1/E1 Channel in the system.
This number is provided as key to allow the manager to
map this entry to a corresponding Resource Table entry. |
| INT hds3T1E1Clear | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.5 | INTEGER | read-write | Determines if the port supports T1 or E1 unframed. |
| NTF hds3T1E1ConfigTrap | 1.3.6.1.4.1.644.2.4.2.2.0.2 | | | This trap is used to notify a NMS that a user has updated
the Link configuration for a given HDS3-T1/E1 channel entry. |
| INT hds3T1E1EsfFormat | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.10 | INTEGER | read-write | Determines the type of ESF network commands the T-1 link
will respond to. It has no meaning for D4 networks. With ESF
networks, this information must be obtained from the network
supplier. |
| INT hds3T1E1Framing | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.6 | INTEGER | read-write | Determines the type of framing used on the line.
Choose between T1 SuperFrame 'D4', Extended SuperFrame (ESF),
or T1 Unframed. When value of hds3T1E1Clear is set to
unframed (2), the only valid framing options are: e1Unframed(4)
or t1Unframed(7). |
| DEC hds3T1E1Gr303Facility | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.13 | DecisionType | read-only | Enables link to be configured as a Gr303 Facility |
| INT hds3T1E1IdleCode | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.11 | INTEGER | read-write | Determines the whether the code that will be transmitted over
the unused links will be 'idle' or 'busy' (all 1's). |
| ONE hds3T1E1InterNational | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.15 | OneByteField | read-write | Enables InterNational S(i) Spare bit to be set to zero or one.
This single byte field can be changed to set the values
of the Bit 1 of TS0 G.704 frame as depicted below:
reserved bits S(i)
-------------------------- -----
0 0 0 0 0 0 0 1 = 01 (default)
Values should be entered in Hex. If reserved bits are changed,
an error code (427) will be returned in the command status. |
| hds3T1E1LinkConfigEntry | 1.3.6.1.4.1.644.2.4.2.2.1.2.1 | | not-accessible | The conceptual row of the HDS-3 T-1 Link Configuration table.
A row in this table cannot be added or deleted, only modified. |
| hds3T1E1LinkConfigTable | 1.3.6.1.4.1.644.2.4.2.2.1.2 | | not-accessible | This is the HDS-3 T-1 Link Configuration table which consists
of an entry for each of the card's 28 links. The total number of
entries depends on the number of HDS3 cards in the nest. |
| ONE hds3T1E1NationalBits | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.14 | OneByteField | read-write | Enables E1 National S-bits to be set to zero or one.
This single byte field can be changed to set the values
of the E1 NFA byte in odd frames as depicted below:
sa8 sa7 sa6 sa5 sa4 reserved bits
--- --- --- --- --- -------------
1 1 1 1 1 0 0 0 = F8 (default)
Values should be entered in Hex. If reserved bits are changed,
an error code (427) will be returned in the command status. |
| FUN hds3T1E1NetLoop | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.7 | FunctionSwitch | read-write | Determines whether or not the module should respond to loop
diagnostic commands received from the network supplier. Select
'enable' unless the commands are to be passed to another HDS3
device. |
| INT hds3T1E1RecoverTime | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.9 | INTEGER | read-write | This is the red alarm timeout value. Determines the amount
of seconds the port will wait to stop sending the yellow alarm
when coming out of a red alarm condition. This field does not
apply to E1 links. |
| POR hds3T1E1Status | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.4 | PortStatus | read-write | Dictates the current status of the link, in-service or
out-of-service. |
| DEC hds3T1E1YelAlrm | 1.3.6.1.4.1.644.2.4.2.2.1.2.1.8 | DecisionType | read-write | Causes the module to discard data and send a yellow alarm if it
is in a red alarm condition after a 3 second period. 'Yes' must
be chosen if the network supplier is a common carrier, such as a
telephone company. |
| STR hds3UnitName | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.8 | DisplayString | read-write | This is the description of the bay or device this equipment
is part of. |
| INT hds3XmtAIS | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.18 | INTEGER | read-write | The Transmitted bit pattern that used when the HDS3 port
is in error. |
| INT hds3XmtAISLocalLoop | 1.3.6.1.4.1.644.2.4.2.2.1.1.1.16 | INTEGER | read-write | The Transmitted bit pattern used when the HDS3 port
is in Local Loop. |