ERI-DNX-HDS3-MIB :: hds3T1E1EsfFormat

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsERI-DNX-HDS3-MIBhds3T1E1EsfFormat

hds3T1E1EsfFormat

Module: ERI-DNX-HDS3-MIB

OID (symbolic): ERI-DNX-HDS3-MIB::hds3T1E1EsfFormat

OID (numeric): 1.3.6.1.4.1.644.2.4.2.2.1.2.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Determines the type of ESF network commands the T-1 link will respond to. It has no meaning for D4 networks. With ESF networks, this information must be obtained from the network supplier.

What is hds3T1E1EsfFormat?

This read-write setting picks which ESF network command convention the T1 link responds to, AT&T 54016 or ANSI T1.403; it has no effect on D4-framed links. Admins must get this value from the network/carrier since it has to match the far end's ESF signaling.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.644.2.4.2.2.1.2.1.10
snmpwalk -v2c -c public <target> ERI-DNX-HDS3-MIB::hds3T1E1EsfFormat

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.644.2.4.2.2.1.2.1.10.1
snmpget -v2c -c public <target> ERI-DNX-HDS3-MIB::hds3T1E1EsfFormat.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.644.2.4.2.2.1.2.1.10.1 i <value>

Start monitoring Eastern Research Inc. (ERI) DNX digital cross-connect/multiplexer (Hybrid DS3 card) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ERI-DNX-HDS3-MIB::hds3T1E1EsfFormat OID value, configure state conditions and alerts, and monitor any Eastern Research Inc. (ERI) DNX digital cross-connect/multiplexer (Hybrid DS3 card) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.644eriEnterpriseRootERI-ROOT-SMI
1.3.6.1.4.1.644.2eriProductsERI-ROOT-SMI
1.3.6.1.4.1.644.2.4dnxERI-DNX-SMC-MIB
1.3.6.1.4.1.644.2.4.2devicesERI-DNX-SMC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.644.2.4.2.2dnxHDS3ERI-DNX-HDS3-MIB
1.3.6.1.4.1.644.2.4.2.2.1hds3ConfigERI-DNX-HDS3-MIB
1.3.6.1.4.1.644.2.4.2.2.1.2hds3T1E1LinkConfigTableERI-DNX-HDS3-MIB
1.3.6.1.4.1.644.2.4.2.2.1.2.1hds3T1E1LinkConfigEntryERI-DNX-HDS3-MIB
1.3.6.1.4.1.644.2.4.2.2.1.2.1.10hds3T1E1EsfFormatERI-DNX-HDS3-MIB