ERI-DNX-HDS3-MIB :: hds3LIUBertErrSecs

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsERI-DNX-HDS3-MIBhds3LIUBertErrSecs

hds3LIUBertErrSecs

Module: ERI-DNX-HDS3-MIB

OID (symbolic): ERI-DNX-HDS3-MIB::hds3LIUBertErrSecs

OID (numeric): 1.3.6.1.4.1.644.2.4.2.2.2.2.1.4

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This is the number of LIU Bert Errored seconds.

What is hds3LIUBertErrSecs?

This read-only counter reports the number of errored seconds recorded during the LIU's bit error rate test. Admins check this after a BERT run to judge whether the physical line passed or showed unacceptable error activity.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.644.2.4.2.2.2.2.1.4
snmpwalk -v2c -c public <target> ERI-DNX-HDS3-MIB::hds3LIUBertErrSecs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.644.2.4.2.2.2.2.1.4.1
snmpget -v2c -c public <target> ERI-DNX-HDS3-MIB::hds3LIUBertErrSecs.1

Start monitoring Eastern Research Inc. (ERI) DNX digital cross-connect/multiplexer (Hybrid DS3 card) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ERI-DNX-HDS3-MIB::hds3LIUBertErrSecs OID value, configure state conditions and alerts, and monitor any Eastern Research Inc. (ERI) DNX digital cross-connect/multiplexer (Hybrid DS3 card) from a single console.

How to Use in IPNetwork Monitor

Select an Eastern Research Inc. (ERI) DNX digital cross-connect/multiplexer (Hybrid DS3 card) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hds3LIUBertErrSecs into the Find box to locate it in the OID tree, then select it and click OK. This is the number of LIU Bert Errored seconds. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.644eriEnterpriseRootERI-ROOT-SMI
1.3.6.1.4.1.644.2eriProductsERI-ROOT-SMI
1.3.6.1.4.1.644.2.4dnxERI-DNX-SMC-MIB
1.3.6.1.4.1.644.2.4.2devicesERI-DNX-SMC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.644.2.4.2.2dnxHDS3ERI-DNX-HDS3-MIB
1.3.6.1.4.1.644.2.4.2.2.2hds3DiagERI-DNX-HDS3-MIB
1.3.6.1.4.1.644.2.4.2.2.2.2hds3LIUTableERI-DNX-HDS3-MIB
1.3.6.1.4.1.644.2.4.2.2.2.2.1hds3LIUEntryERI-DNX-HDS3-MIB
1.3.6.1.4.1.644.2.4.2.2.2.2.1.4hds3LIUBertErrSecsERI-DNX-HDS3-MIB