| OID symbolic | OID numeric | Type | Access | Description |
| dnxStm1Oc3 | 1.3.6.1.4.1.644.2.4.2.7 | | | |
| dnxStm1Oc3Enterprise | 1.3.6.1.4.1.644.2.4.2.7.0 | | | ERI DNX Stm1Oc3 Device Enterprise for Alarms/Events |
| eriDNXStm1Oc3MIB | 1.3.6.1.4.1.644.3.9 | | | The ERI Enterprise MIB Module for the DNX STM1 and OC3 devices. |
| I32 optDevAssignedToNest | 1.3.6.1.4.1.644.2.4.2.7.1.1.1.11 | Integer32 | read-write | Identifies the virtual Nest to use for the STM1-X or
OC3-X modules. Only applicable in DNX-88 systems and can only
be SET for cards configured in even numbered DNX slots. |
| ADR optDevCfgAddr | 1.3.6.1.4.1.644.2.4.2.7.1.1.1.1 | NestSlotAddress | read-only | This number uniquely identifies a STM1/OC3 Device resource.
This number will be used throughout the system to identify
a unique resource. |
| I32 optDevCfgResource | 1.3.6.1.4.1.644.2.4.2.7.1.1.1.2 | Integer32 | read-only | Uniquely identifies an STM1/OC3 Device in the system.
This number is provided as key to allow the manager to
map this entry to a corresponding Resource Table entry. |
| INT optDevCmdStatus | 1.3.6.1.4.1.644.2.4.2.7.1.1.1.9 | INTEGER | read-write | The command status for this link configuration row/record.
The value used in a SET will be replaced by a response
value in the GET RESPONSE indicating success or failure.
Default Response State used in GET RESPONSE Command
ready-for-command (0)
initial default status for a row
Stm1Oc3 Device Cfg Commands used in SET Command (1..99)
update-config(1),
Change existing Stm1Oc3 Device Configuration
Response States used in GET RESPONSE Command (100..199)
update-successful (101)
Device data has been successfully changed
Stm1Oc3 Device Config Error Codes used in GET RESPONSE Command (400..799)
err-general-opt-config-error (400)
Unknown Device configuration error occurred
err-au4Seq-cannot-be-mixed-framing (402)
Au4 sequential mode supports only all-E1 or all-T1 Payloads
err-invalid-opt-dev-command (403)
Unrecognized device command-action
err-device-is-protection-module (414)
Can't configure Device designated as Protection (odd # slot)
err-invalid-multiplex-map (415)
Configured multiplexing structure not valid for device type
err-invalid-payload-framing (416)
Unrecognized payload group type
err-invalid-xlink-nest-num (419)
X-Link cannot be assigned to selected Nest
err-invalid-line-timing (421)
Unrecognized clock setting
err-ts-alloc-not-applicable (424)
Timeslot Alloc can only be configured for STM1 or OC3
cards in Standalone DNX systems
err-xlink-pair-not-applicable (427)
X-Link assignement can only be changed for STM1X or
OC3X cards in DNX88 systems.
err-data-locked-by-another-user (450)
Another administrative user is making changes to this
part of the system via a terminal session. Check Event
Log for user name.
err-snmp-parse-failed (500)
Agent could not parse variable
err-invalid-snmp-type (501)
Variable ASN type does not match Agent defined type
err-invalid-snmp-var-size (502)
Variable size is too big |
| NTF optDevConfigTrap | 1.3.6.1.4.1.644.2.4.2.7.0.1 | | | This trap is used to notify a NMS that a user has updated
the configuration for a given Stm1Oc3 Device entry. |
| INT optDevMultiplexMode | 1.3.6.1.4.1.644.2.4.2.7.1.1.1.4 | INTEGER | read-write | Determines the Stm1Oc3 Multiplexing Map Structure to be used:
For STM1 SDH Device choose au3, au4, or au4-g707:
-------------------------------------------------
(0) au3 - Maps the AUG (Administrative Unit Group) to an AU-3:
C-12VC-12TU-12TUG-2VC-3AU-3AUGSTM-1
(1) au4 - Maps the AUG (Administrative Unit Group) to an AU-4:
C-12VC-12TU-12TUG-2TUG-3VC-4AU-4AUGSTM-1
(4) au4-vc3-Seq - Same format as AU-4 but uses sequential link numbering scheme
For OC3 SONET Device sts-3 or sts-3c:
-------------------------------------
(2) sts-3 - Maps the STS-3 (Synchronous Transport Signal 3) to an SPE:
VT-1.5VT-GSPESTS-3OC-3
(3) sts-3c - Maps the STS-3 (Synchronous Transport Signal 3) to an SPE 3c:
SPE3cSTS-3OC-3 |
| PAY optDevPayload1 | 1.3.6.1.4.1.644.2.4.2.7.1.1.1.6 | PayLoadGroupType | read-write | Indicates the group framing type to be used for links 1 through 28.
Using E1, links 22 through 28 are not used. |
| PAY optDevPayload2 | 1.3.6.1.4.1.644.2.4.2.7.1.1.1.7 | PayLoadGroupType | read-write | Indicates the tgroup framing type to be used for links 29 through 56.
Using E1, links 50 through 56 are not used. |
| PAY optDevPayload3 | 1.3.6.1.4.1.644.2.4.2.7.1.1.1.8 | PayLoadGroupType | read-write | Indicates the group framing type to be used for links 57 through 84.
Using E1, links 78 through 84 are not used. |
| INT optDevTsAlloc | 1.3.6.1.4.1.644.2.4.2.7.1.1.1.10 | INTEGER | read-write | Identifies the Timeslot allocation method to use for
the STM-1 or OC-3 module. Only applies for stand-alone
DNX-11 or DNX-4 systems. DNX-88 systems always use NORMAL. |
| INT optDevType | 1.3.6.1.4.1.644.2.4.2.7.1.1.1.3 | INTEGER | read-only | Identifies the Device as an STM1, OC3, STM1X, or OC3X module. |
| opticalConfig | 1.3.6.1.4.1.644.2.4.2.7.1 | | | |
| opticalDevConfigEntry | 1.3.6.1.4.1.644.2.4.2.7.1.1.1 | | not-accessible | The conceptual row of the STM1/OC3 Device Configuration table.
A row in this table cannot be added or deleted, only modified. |
| opticalDevConfigTable | 1.3.6.1.4.1.644.2.4.2.7.1.1 | | not-accessible | This is the STM1/OC3 Device Configuration table which consists
of an entry for each of the STM1/OC3 cards. The total number of
entries depends on the number of STM1/OC3 cards in the Node. |
| opticalDiag | 1.3.6.1.4.1.644.2.4.2.7.2 | | | |
| opticalMapperStatusEntry | 1.3.6.1.4.1.644.2.4.2.7.2.2.1 | | not-accessible | The conceptual row of the Stm1Oc3 Mapper Status table.
A row in this table cannot be added or deleted, only modified. |
| opticalMapperStatusTable | 1.3.6.1.4.1.644.2.4.2.7.2.2 | | not-accessible | This is the Stm1Oc3 Mapper Status table which consists
of an entry for each of the 3 STM1/OC3 Mapper Payloads. The
total number of entries depends on the number of STM1/OC3 cards
in the Node. |
| opticalTransportStatusEntry | 1.3.6.1.4.1.644.2.4.2.7.2.3.1 | | not-accessible | The conceptual row of the Stm1Oc3 Transport Status table.
A row in this table cannot be added or deleted, only modified. |
| opticalTransportStatusTable | 1.3.6.1.4.1.644.2.4.2.7.2.3 | | not-accessible | This is the Stm1Oc3 Transport Status table which consists
of an entry for each of the STM1/OC3 Transport Overhead. The
total number of entries depends on the number of Stm1Oc3 cards
in the Node. |
| opticalTUStatusEntry | 1.3.6.1.4.1.644.2.4.2.7.2.1.1 | | not-accessible | The conceptual row of the Stm1Oc3 Tributary Unit Status table.
A row in this table cannot be added or deleted, only modified. |
| opticalTUStatusTable | 1.3.6.1.4.1.644.2.4.2.7.2.1 | | not-accessible | This is the Stm1Oc3 Tributary Unit Status table which consists
of an entry for each of the card's 84 links. The total number of
entries depends on the number of STM1/OC3 cards in the Node. |
| INT optLineTiming | 1.3.6.1.4.1.644.2.4.2.7.1.1.1.5 | INTEGER | read-write | Identifies the type of Clock Transmit Timing to use for
the STM-1 or OC-3 module. |
| INT optMapperCmdStatus | 1.3.6.1.4.1.644.2.4.2.7.2.2.1.10 | INTEGER | read-write | This is the command status for the Framer Row.
The value used in a SET will be replaced by a response
value in the GET RESPONSE indicating success or failure.
Default Response State used in GET RESPONSE Command
ready-for-command (0)
initial default status for a row
Mapper Action Commands used in SET Command (1..99)
updateTest (1)
Can be used optionally when activating loops and berts
in order to get status code back in response
clearErrors (14)
Resets all error counters and bert test time to zero
Response States used in GET RESPONSE Command (100..199)
update-successful (101)
Test action has been successfully performed
clear-successful (114)
Error counts have been successfully cleared
The Error Codes used in GET RESPONSE Command (200..799)
err-general-test-error (200)
Unknown Test request error occurred.
err-invalid-loop-type (202)
Unrecognized loop selection
err-field-cannot-be-set (206)
Read-only field was included in SET request
err-snmp-parse-failed (500)
Agent could not parse variable
err-invalid-snmp-type (501)
Variable ASN type does not match Agent defined type
err-invalid-snmp-var-size (502)
Variable size is too big |
| C32 optMapperErrFreeSecs | 1.3.6.1.4.1.644.2.4.2.7.2.2.1.5 | Counter32 | read-only | This is the total number of Mapper Error Free Seconds. |
| C32 optMapperErrSecs | 1.3.6.1.4.1.644.2.4.2.7.2.2.1.4 | Counter32 | read-only | This is the total number of Errored Seconds for this Mapper Payload. |
| INT optMapperLoop | 1.3.6.1.4.1.644.2.4.2.7.2.2.1.6 | INTEGER | read-write | Indicates the loopback status of the Stm1Oc3 Mapper for this device..
off (0) - indicates loopback is disabled
local (1) - indicates Mapper local data is looped back to itself
line (3) - entire Mapper Frame is looped, framing is not regenerated |
| C32 optMapperPathAISErrs | 1.3.6.1.4.1.644.2.4.2.7.2.2.1.8 | Counter32 | read-only | This is the total number of Mapper Path Alarm Indication Signal
Errored Seconds. |
| C32 optMapperPathLOPErrsEx | 1.3.6.1.4.1.644.2.4.2.7.2.2.1.7 | Counter32 | read-only | This is the total number of Mapper Path Loss of Pointer Errored
Seconds. |
| C32 optMapperPathRDIErrs | 1.3.6.1.4.1.644.2.4.2.7.2.2.1.9 | Counter32 | read-only | This is the total number of Mapper Path Remote Defect Indication
Errored Seconds. |
| INT optMapperState | 1.3.6.1.4.1.644.2.4.2.7.2.2.1.3 | INTEGER | read-only | This number uniquely identifies the Mapper Payload State.
ok (0) - In Sync
yel (2) - Yellow Alarm
ais (8) - Sending All Ones
lop (16) - Loss of Ptr
lof (32) - Loss of Frame
los (64) - Loss of Signal
rdi (128) - Receive Defect Indicator
red (2048) - Red Alarm
cfa (4096) - Carrier Frame Alignment
oos (65535) - Out of Service
txSlip (2097152) - Transmit Slip
rxSlip (4194304) - Receive Slip
sef (8388608) - Severely Errored Frames
slip (6291456) - Transmit/Receive Slip
underTest(1073741824) - Running Bit Error Test (BERT)
errors (2147483647) - Multiple Errors displays raw bit field value |
| ADR optMapperStatusAddr | 1.3.6.1.4.1.644.2.4.2.7.2.2.1.1 | LinkPortAddress | read-only | This number uniquely identifies a STM1/OC3 Mapper Payload.
This number will be used throughout the system to identify
a unique resource. |
| I32 optMapperStatusResrcId | 1.3.6.1.4.1.644.2.4.2.7.2.2.1.2 | Integer32 | read-only | This number uniquely identifies a STM1/OC3 Mapper resource.
This number is provided as key to allow the manager to
map this entry to a corresponding Resource Table entry. |
| LIN optT1E1CfgCmdStatus | 1.3.6.1.4.1.644.2.4.2.7.1.2.1.10 | LinkCmdStatus | read-write | The command status for this link configuration row/record.
The value used in a SET will be replaced by a response
value in the GET RESPONSE indicating success or failure.
Default Response State used in GET RESPONSE Command
ready-for-command (0)
initial default status for a row
optical T1E1 Link Commands used in SET Command (1..199)
update(1)
Change existing Link Configuration
inServiceAll (7)
Change Link Status to in-service for all links
within the same payload.
copyToAll (9)
Copy T1/E1 Link configuration to all other links
within the same payload
outOfServiceAll (12)
Change Link Status to out-of-service for all links
within the same payload.
Response States used in GET RESPONSE Command (100..199)
update-successful (101)
Link data has been successfully changed
insvc-successful (107)
All Payload Links have been successfully placed In Service
copy-successful (109)
Link data has been successfully copied to other links
oos-successful (112)
All Payload Links have been successfully placed Out of Service
optical T1E1 Link Config Error Codes used in GET RESPONSE Command (400..699)
err-general-link-config-error (400)
Unknown link configuration error occurred
err-invalid-link-status (401)
Unrecognized link status setting
err-invalid-link-framing (402)
Line framing type not valid for link type
err-invalid-link-command (403)
Unrecognized link command-action
err-invalid-esf-format (405)
ESF type not applicable to link type
err-invalid-red-timeout (412)
Unrecognized red alarm timeout
err-invalid-idle-code (413)
Unrecognized unused TSs code
err-device-in-standby (414)
Can't change config for designated Standby device
err-data-locked-by-another-user (450)
Another administrative user is making changes to this
part of the system via a terminal session. Check Event
Log for user name
err-snmp-parse-failed (500)
Agent could not parse variable
err-invalid-snmp-type (501)
Variable ASN type does not match Agent defined type
err-invalid-snmp-var-size (502)
Variable size is too big |
| ADR optT1E1CfgLinkAddr | 1.3.6.1.4.1.644.2.4.2.7.1.2.1.1 | LinkPortAddress | read-only | This number uniquely identifies a Stm1Oc3 T1/E1 Link resource.
This number will be used throughout the system to identify
a unique resource. |
| STR optT1E1CfgLinkName | 1.3.6.1.4.1.644.2.4.2.7.1.2.1.3 | DisplayString | read-write | This is the user friendly text name to identify the link. |
| I32 optT1E1CfgResource | 1.3.6.1.4.1.644.2.4.2.7.1.2.1.2 | Integer32 | read-only | Uniquely identifies an Stm1Oc3 T1/E1 Link in the system.
This number is provided as key to allow the manager to
map this entry to a corresponding Resource Table entry. |
| INT optT1E1Clear | 1.3.6.1.4.1.644.2.4.2.7.1.2.1.5 | INTEGER | read-write | Determines if the port supports T1 or E1 unframed clear mode
or framed clear mode. |
| NTF optT1E1ConfigTrap | 1.3.6.1.4.1.644.2.4.2.7.0.2 | | | This trap is used to notify a NMS that a user has updated
the configuration for a given Stm1Oc3 T1/E1 Link entry. |
| INT optT1E1EsfFormat | 1.3.6.1.4.1.644.2.4.2.7.1.2.1.8 | INTEGER | read-write | Determines the type of ESF network commands the T-1 link
will respond to. It has no meaning for D4 or E1 networks.
With ESF networks, this information must be obtained from
the network supplier. |
| INT optT1E1Framing | 1.3.6.1.4.1.644.2.4.2.7.1.2.1.6 | INTEGER | read-write | Determines the type of framing used on the line.
Choose between T1 SuperFrame 'D4', Extended SuperFrame (ESF),
or T1 Unframed. When value of optT1E1Clear is set to
unframed (2), the only valid framing options are: e1Unframed(4)
or t1Unframed(7). |
| ONE optT1E1InterNational | 1.3.6.1.4.1.644.2.4.2.7.1.2.1.12 | OneByteField | read-write | Enables InterNational S(i) Spare bit to be set to zero or one.
This single byte field can be changed to set the values
of the Bit 1 of TS0 G.704 frame as depicted below:
reserved bits S(i)
-------------------------- -----
0 0 0 0 0 0 0 1 = 01 (default)
Values should be entered in Hex. If reserved bits are changed,
an error code (427) will be returned in the command status. |
| optT1E1LinkConfigEntry | 1.3.6.1.4.1.644.2.4.2.7.1.2.1 | | not-accessible | The conceptual row of the Stm1Oc3 T1/E1 Link Configuration table.
A row in this table cannot be added or deleted, only modified. |
| optT1E1LinkConfigTable | 1.3.6.1.4.1.644.2.4.2.7.1.2 | | not-accessible | This is the Stm1Oc3 T1/E1 Link Configuration table which consists
of an entry for each of the card's 84 links. The total number of
entries depends on the number of STM1 and/or OC3 cards in the Node. |
| ONE optT1E1NationalBits | 1.3.6.1.4.1.644.2.4.2.7.1.2.1.11 | OneByteField | read-write | Enables E1 National S-bits to be set to zero or one.
This single byte field can be changed to set the values
of the E1 NFA byte in odd frames as depicted below:
sa8 sa7 sa6 sa5 sa4 reserved bits
--- --- --- --- --- -------------
1 1 1 1 1 0 0 0 = F8 (default)
Values should be entered in Hex. If reserved bits are changed,
an error code (427) will be returned in the command status. |
| INT optT1E1RecoverTime | 1.3.6.1.4.1.644.2.4.2.7.1.2.1.7 | INTEGER | read-write | This is the red alarm timeout value. Determines the amount
of seconds the port will wait to stop sending the yellow alarm
when coming out of a red alarm condition. |
| POR optT1E1Status | 1.3.6.1.4.1.644.2.4.2.7.1.2.1.4 | PortStatus | read-write | Dictates the current status of the link, in-service or
out-of-service. |
| INT optT1E1UnusedTSs | 1.3.6.1.4.1.644.2.4.2.7.1.2.1.9 | INTEGER | read-write | Determines the whether the code that will be transmitted over
the unused timeslots will be 'idle' or 'busy' (all 1's). |
| INT optTransportCmdStatus | 1.3.6.1.4.1.644.2.4.2.7.2.3.1.12 | INTEGER | read-write | This is the command status for the Framer Row.
The value used in a SET will be replaced by a response
value in the GET RESPONSE indicating success or failure.
Default Response State used in GET RESPONSE Command
ready-for-command (0)
initial default status for a row
Transport Action Commands used in SET Command (1..99)
updateTest (1)
Can be used optionally when activating loops and berts
in order to get status code back in response
clearErrors (14)
Resets all error counters and bert test time to zero
Response States used in GET RESPONSE Command (100..199)
update-successful (101)
Test action has been successfully performed
clear-successful (114)
Error counts have been successfully cleared
The Error Codes used in GET RESPONSE Command (400..799)
err-general-test-error (400)
Unknown Test request error occurred.
err-invalid-loop-type (402)
Unrecognized loop selection
err-field-cannot-be-set (406)
Read-only field was included in SET request
err-snmp-parse-failed (500)
Agent could not parse variable
err-invalid-snmp-type (501)
Variable ASN type does not match Agent defined type
err-invalid-snmp-var-size (502)
Variable size is too big |
| C32 optTransportErrFreeSecs | 1.3.6.1.4.1.644.2.4.2.7.2.3.1.5 | Counter32 | read-only | This is the total number of Transport Error Free Seconds. |
| C32 optTransportErrSecs | 1.3.6.1.4.1.644.2.4.2.7.2.3.1.4 | Counter32 | read-only | This is the total number of Errored Seconds for this Transport Overhead. |
| INT optTransportLaserState | 1.3.6.1.4.1.644.2.4.2.7.2.3.1.3 | INTEGER | read-write | This specifies the State of the Laser Interface. |
| C32 optTransportLineAISErrs | 1.3.6.1.4.1.644.2.4.2.7.2.3.1.7 | Counter32 | read-only | This is the total number of Transport Line Alarm Indication Signal
Errored Seconds. |
| C32 optTransportLineLOFErrs | 1.3.6.1.4.1.644.2.4.2.7.2.3.1.10 | Counter32 | read-only | This is the total number of Transport Line Loss of Frame Errored
Seconds. |
| C32 optTransportLineLOSErrs | 1.3.6.1.4.1.644.2.4.2.7.2.3.1.11 | Counter32 | read-only | This is the total number of Transport Line Loss of Signal Errored
Seconds. |
| C32 optTransportLineOOFErrs | 1.3.6.1.4.1.644.2.4.2.7.2.3.1.9 | Counter32 | read-only | This is the total number of Transport Line Out of Frame Errored
Seconds. |
| C32 optTransportLineRDIErrs | 1.3.6.1.4.1.644.2.4.2.7.2.3.1.8 | Counter32 | read-only | This is the total number of Transport Line Remote Defect Indication
Errored Seconds. |
| INT optTransportLoop | 1.3.6.1.4.1.644.2.4.2.7.2.3.1.6 | INTEGER | read-write | Indicates the loopback status of the Stm1Oc3 Transport for this device.
off (0) - indicates Transport loopback is disabled
terminal (1) - The optical line interface transmit driver is looped back
to the optical receiver. Ultimately the payload is reflected
back to the Switch Fabric and the PCM Highway of the DNX
Backplane.
facility (2) - The Fiber Optic path is looped back to the facility.
pathFacility (3) - The Stm1Oc3 incoming data (Rx) is transmitted back to its source
via the Tx path. The bus that interfaces to the mappers is in
loopback, and the entire payload is returned to its source with a
refreshed frame structure. |
| ADR optTransportStatusAddr | 1.3.6.1.4.1.644.2.4.2.7.2.3.1.1 | NestSlotAddress | read-only | This number uniquely identifies a STM1/OC3 Transport Overhead
Nest and Slot number. This number format will be used throughout
the system to identify a resource. |
| I32 optTransportStatusResrcId | 1.3.6.1.4.1.644.2.4.2.7.2.3.1.2 | Integer32 | read-only | This number uniquely identifies a STM1/OC3 Transport resource.
This number is provided as key to allow the manager to
map this entry to a corresponding Resource Table entry. |
| ADR optTUStatusAddr | 1.3.6.1.4.1.644.2.4.2.7.2.1.1.1 | LinkPortAddress | read-only | This number uniquely identifies a Stm1Oc3 TU link.
This number will be used throughout the system to identify
a unique resource. |
| C32 optTUStatusAisErrs | 1.3.6.1.4.1.644.2.4.2.7.2.1.1.5 | Counter32 | read-only | This is the total number of TU Alarm Indication Signal Errored Seconds. |
| C32 optTUStatusErrFreeSecs | 1.3.6.1.4.1.644.2.4.2.7.2.1.1.11 | Counter32 | read-only | This is the total number of Error-Free seconds for the Tributary Unit. |
| C32 optTUStatusErrSecs | 1.3.6.1.4.1.644.2.4.2.7.2.1.1.4 | Counter32 | read-only | This is the total number of Errored Seconds for the Tributary Unit. |
| INT optTUStatusLinkState | 1.3.6.1.4.1.644.2.4.2.7.2.1.1.3 | INTEGER | read-only | Determines the current STM1/OC3 Tributary Unit status of the link.
ok (0) - In Sync
yel (2) - Yellow Alarm
ais (8) - Sending All Ones
lof (32) - Loss of Frame
los (64) - Loss of Signal
red (2048) - Red Alarm
cfa (4096) - Carrier Frame Alignment
oos (65535) - Out of Service
txSlip (2097152) - Transmit Slip
rxSlip (4194304) - Receive Slip
sef (8388608) - Severely Errored Frames
slip (6291456) - Transmit/Receive Slip
underTest(1073741824) - Running Bit Error Test (BERT)
errors (2147483647) - Multiple Errors displays raw bit field value |
| C32 optTUStatusLopErrs | 1.3.6.1.4.1.644.2.4.2.7.2.1.1.6 | Counter32 | read-only | This is the total number of TU Loss of Pointer Errored Seconds. |
| C32 optTUStatusPSLMErrs | 1.3.6.1.4.1.644.2.4.2.7.2.1.1.9 | Counter32 | read-only | This is the total number of TU Path Signal Label Mismatch Errored Seconds. |
| C32 optTUStatusPSLUErrs | 1.3.6.1.4.1.644.2.4.2.7.2.1.1.10 | Counter32 | read-only | This is the total number of TU Path Signal Label Unstable Errored Seconds. |
| C32 optTUStatusRdiTUErrs | 1.3.6.1.4.1.644.2.4.2.7.2.1.1.7 | Counter32 | read-only | This is the total number of TU Remote Defect Indication Errored Seconds. |
| I32 optTUStatusResrcId | 1.3.6.1.4.1.644.2.4.2.7.2.1.1.2 | Integer32 | read-only | This number uniquely identifies a Stm1Oc3 TU resource.
This number is provided as key to allow the manager to
map this entry to a corresponding Resource Table entry. |
| C32 optTUStatusRfiTUErrs | 1.3.6.1.4.1.644.2.4.2.7.2.1.1.8 | Counter32 | read-only | This is the total number of TU Remote Failure Indication Errored Seconds. |