All MIBs › CPQAPPG80-MIB
Description: Compaq SAN Appliance MIB for HSG80 storage controllers, covering agent state, subsystem, logical and physical disks, storage sets, and snapshots
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CPQAPPG80-MIB?
CPQAPPG80-MIB is Compaq's (later HP's) SNMP MIB for the SAN Appliance product line built around the HSG80 storage controller, providing management of the SAN management agent itself along with the storage subsystems, controllers, logical/physical disks, storage sets, and snapshots it manages. It exposes agent-level data (version, active state, refresh time, host name) as well as per-subsystem tables identifying each storage subsystem, its two redundant controllers, and its EMU (environmental monitoring unit) state. Its monitoring value spans both the health of the management agent software (whether it is active and how current its data is) and the hardware status of the SAN storage subsystem - controller pairing, redundancy state, and environmental/EMU alarms across physical and logical disks. Given its "cpqsmav1"/"cpqSanAppliance" naming, it likely depends on or coexists with other Compaq/HP storage MIBs (e.g., CPQHSV110V3-MIB) for controller-specific detail. It is typically deployed in legacy Compaq/HP StorageWorks SAN environments where administrators rely on CPQAPPG80-MIB SNMP monitoring of HSG80-based storage subsystems for controller failover and environmental faults.
IPNetwork Monitor allows you to monitor SNMP objects defined in CPQAPPG80-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Compaq/HP StorageWorks SAN Appliance (HSV/HSG80-based)
Monitoring Examples
An operator would poll cpqSMAAgentActive and cpqSMAAgentRefreshTime to confirm the SAN management agent is running and its data is current, then walk cpqSMASubsystemTable/cpqSMASubsystemEntry to see each subsystem's cpqSMASubsystemControllerOne/Two identifiers and cpqSMASubsystemEMUState. An EMU state indicating a fault (e.g., over-temperature or fan failure reported through the environmental monitoring unit) alongside a missing or degraded controller pairing would flag a storage subsystem at risk of losing redundancy.
What Can Be Monitored
- SAN management agent status/version
- storage subsystem controller pairing
- environmental monitoring unit (EMU) state
- logical/physical disk and storage set status
- snapshot status
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| enterprises |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| compaq | 1.3.6.1.4.1.232 | |||
| cpqSanAppliance | 1.3.6.1.4.1.232.151 | |||
| cpqsmav1 | 1.3.6.1.4.1.232.151.100 | |||
| cpqSMAAgent | 1.3.6.1.4.1.232.151.100.1 | |||
| INT cpqSMAAgentVersionMajor | 1.3.6.1.4.1.232.151.100.1.1 | INTEGER | read-only | The version of the agent |
| INT cpqSMAAgentVersionMinor | 1.3.6.1.4.1.232.151.100.1.2 | INTEGER | read-only | The version of the agent |
| INT cpqSMAAgentActive | 1.3.6.1.4.1.232.151.100.1.3 | INTEGER | read-only | The state of the agent |
| INT cpqSMAAgentRefreshTime | 1.3.6.1.4.1.232.151.100.1.4 | INTEGER | read-write | The time interval before the next data collection. The information about the HSG80 is collected periodically. A thread gathers the information and stores it in memory. This variable is used to specify the time interval in minutes (MINUTES) between each update. |
| STR cpqSMAAgentHostName | 1.3.6.1.4.1.232.151.100.1.5 | DisplayString | read-only | The name of the local machine where the agent is running. |
| cpqSMASubsystem | 1.3.6.1.4.1.232.151.100.2 | |||
| cpqSMASubsystemTable | 1.3.6.1.4.1.232.151.100.2.1 | not-accessible | The table of Subsystems | |
| cpqSMASubsystemEntry | 1.3.6.1.4.1.232.151.100.2.1.1 | not-accessible | A table entry for a Subsystem | |
| INT cpqSMASubsystemIndex | 1.3.6.1.4.1.232.151.100.2.1.1.1 | INTEGER | read-only | The Subsystem index |
| STR cpqSMASubsystemName | 1.3.6.1.4.1.232.151.100.2.1.1.2 | DisplayString | read-only | The name of the Subsystem. |
| INT cpqSMASubsystemControllerOne | 1.3.6.1.4.1.232.151.100.2.1.1.3 | INTEGER | read-only | The index of controller one thats belongs to this subsytem. If the value is -1 then either the controller is not installed or not operational. |
| INT cpqSMASubsystemControllerTwo | 1.3.6.1.4.1.232.151.100.2.1.1.4 | INTEGER | read-only | The index of controller two thats belongs to this subsytem. If the value is -1 then either the controller is not installed or not operational. |
| INT cpqSMASubsystemEMUState | 1.3.6.1.4.1.232.151.100.2.1.1.5 | INTEGER | read-only | Subsystem Environmental Monitoring Unit (EMU) State. nooper(1) - EMU is either not installed or not operational. oper(2) - EMU is operational. |
| STR cpqSMASubsystemEMUVersion | 1.3.6.1.4.1.232.151.100.2.1.1.6 | DisplayString | read-only | Subsystem Environmental Monitoring Unit (EMU) Microcode verion. |
| INT cpqSMASubsystemEMUSensor1 | 1.3.6.1.4.1.232.151.100.2.1.1.7 | INTEGER | read-only | Subsystem Environmental Monitoring Unit (EMU) Sensor1 value (in Celsius). Sensor1 sets the maximum operating temperature for the primary subsystem cabinet. |
| INT cpqSMASubsystemEMUSensor2 | 1.3.6.1.4.1.232.151.100.2.1.1.8 | INTEGER | read-only | Subsystem Environmental Monitoring Unit (EMU) Sensor2 value (in Celsius). Sensor2 also sets the maximum operating temperature for the primary subsystem cabinet. |
| INT cpqSMASubsystemEMUSensor3 | 1.3.6.1.4.1.232.151.100.2.1.1.9 | INTEGER | read-only | Subsystem Environmental Monitoring Unit (EMU) Sensor3 value (in Celsius). Sensor3 sets the maximum operating temperature for the EMU unit. |
| INT cpqSMASubsystemEMUFanspeed | 1.3.6.1.4.1.232.151.100.2.1.1.10 | INTEGER | read-only | Subsystem Fanspeed. FANSPEED=HIGH forces the fans in all connected cabinets to operate at high speed continuously. FANSPEED=AUTOMATIC allows the EMU to control the fan speed for the fans in all connected cabinets. The EMU instructs the fans to operate at high speed when any of the temperature setpoints are exceeded or when one or more fans are not functioning. |
| INT cpqSMASubsystemEMUAlarm | 1.3.6.1.4.1.232.151.100.2.1.1.11 | INTEGER | read-only | Subsystem Environmental Monitoring Unit Alarm. Determines whether or not the audible alarm of the EMU will sound in the following cases: drive failure controller restart The EMU alarm will still sound in the event of an adverse environmental condition, such as a power failure or an over-temperature condition. |
| INT cpqSMASubsystemState | 1.3.6.1.4.1.232.151.100.2.1.1.12 | INTEGER | read-only | Gives us the overall state of the HSG80 subsystem. |
| STR cpqSMASubsystemAlias | 1.3.6.1.4.1.232.151.100.2.1.1.13 | DisplayString | read-only | The Subsystem Alias. |
| cpqSMAController | 1.3.6.1.4.1.232.151.100.3 | |||
| cpqSMAControllerTable | 1.3.6.1.4.1.232.151.100.3.1 | not-accessible | The table of controllers | |
| cpqSMAControllerEntry | 1.3.6.1.4.1.232.151.100.3.1.1 | not-accessible | A table entry for a controller | |
| INT cpqSMAControllerIndex | 1.3.6.1.4.1.232.151.100.3.1.1.1 | INTEGER | read-only | The controller index |
| STR cpqSMAControllerName | 1.3.6.1.4.1.232.151.100.3.1.1.2 | DisplayString | read-only | The name of the controller. |
| STR cpqSMAControllerSerialNumber | 1.3.6.1.4.1.232.151.100.3.1.1.3 | DisplayString | read-only | The serial number of the controller. |
| STR cpqSMAControllerFirmware | 1.3.6.1.4.1.232.151.100.3.1.1.4 | DisplayString | read-only | The firmware of the controller. |
| STR cpqSMAControllerHardware | 1.3.6.1.4.1.232.151.100.3.1.1.5 | DisplayString | read-only | The hardware revision of the controller. |
| STR cpqSMAControllerNodeID | 1.3.6.1.4.1.232.151.100.3.1.1.6 | DisplayString | read-only | Manufacturer assigned ID of the controller. |
| STR cpqSMAControllerIdentifier | 1.3.6.1.4.1.232.151.100.3.1.1.7 | DisplayString | read-only | The user assigned identifier if any of the controller. |
| INT cpqSMAControllerAllocationClass | 1.3.6.1.4.1.232.151.100.3.1.1.8 | INTEGER | read-only | The controller allocation class |
| INT cpqSMAControllerScsiVersion | 1.3.6.1.4.1.232.151.100.3.1.1.9 | INTEGER | read-only | The scsi version of the controller |
| INT cpqSMAControllerRedundancy | 1.3.6.1.4.1.232.151.100.3.1.1.10 | INTEGER | read-only | The redundancy type of the controller |
| INT cpqSMAControllerScsiID | 1.3.6.1.4.1.232.151.100.3.1.1.11 | INTEGER | read-only | The device port scsi address of the controller |
| INT cpqSMAControllerCacheSize | 1.3.6.1.4.1.232.151.100.3.1.1.12 | INTEGER | read-only | The cache size in megabytes. Can be either 64, 128, 256 or 512 MB. |
| INT cpqSMAControllerCacheType | 1.3.6.1.4.1.232.151.100.3.1.1.13 | INTEGER | read-only | The cache type of this controller |
| STR cpqSMAControllerCacheVersion | 1.3.6.1.4.1.232.151.100.3.1.1.14 | DisplayString | read-only | The version of this controllers cache. |
| INT cpqSMAControllerCacheFlushTimer | 1.3.6.1.4.1.232.151.100.3.1.1.15 | INTEGER | read-only | The cache flush timer in sec |
| INT cpqSMAControllerMirrorCache | 1.3.6.1.4.1.232.151.100.3.1.1.16 | INTEGER | read-only | The mirror cache state of this controller |
| STR cpqSMAControllerPort_1_ID | 1.3.6.1.4.1.232.151.100.3.1.1.17 | DisplayString | read-only | The ID of port 1. |
| INT cpqSMAControllerPort_1_Topology | 1.3.6.1.4.1.232.151.100.3.1.1.18 | INTEGER | read-only | The topology of this controller |
| INT cpqSMAControllerPort_1_State | 1.3.6.1.4.1.232.151.100.3.1.1.19 | INTEGER | read-only | The state of this port |
| STR cpqSMAControllerPort_2_ID | 1.3.6.1.4.1.232.151.100.3.1.1.20 | DisplayString | read-only | The ID of port 2. |
| INT cpqSMAControllerPort_2_Topology | 1.3.6.1.4.1.232.151.100.3.1.1.21 | INTEGER | read-only | The topology of this controller |
| INT cpqSMAControllerPort_2_State | 1.3.6.1.4.1.232.151.100.3.1.1.22 | INTEGER | read-only | The state of this port |
| INT cpqSMAControllerPairIndex | 1.3.6.1.4.1.232.151.100.3.1.1.23 | INTEGER | read-only | The index of this controller's pair if FAILOVER mode (cpqSMAControllerRedundancy) is mutlibus or transparent. If there is no FAILOVER mode (cpqSMAControllerRedundancy is single or unknown) then the value is -1. |
| INT cpqSMAControllerCacheState | 1.3.6.1.4.1.232.151.100.3.1.1.24 | INTEGER | read-only | The state of the controller cache. |
| INT cpqSMAControllerBatteryCheckState | 1.3.6.1.4.1.232.151.100.3.1.1.25 | INTEGER | read-only | Battery check state. Specifies whether the controller should perform regular battery condition checks. If CACHE_UPS (ups) the controller does not check the condition of the cache batteries and ignores the battery's state. If NOCACHE_UPS (noups) the controller performs regular cache battery checks and evaluates the condition of the cache batteries. |
| INT cpqSMAControllerBatteryChargeState | 1.3.6.1.4.1.232.151.100.3.1.1.26 | INTEGER | read-only | This is the value in % (percentage) of the amount the controller battery is charged. A value of 0 (zero) means DANGER: BATTERY LIFETIME HAS EXPIRED, REPLACE BATTERY NOW!. |
| STR cpqSMAControllerBatteryExpiryDate | 1.3.6.1.4.1.232.151.100.3.1.1.27 | DisplayString | read-only | The expiry date of the controller battery. |
| INT cpqSMAControllerSubsystemIndex | 1.3.6.1.4.1.232.151.100.3.1.1.28 | INTEGER | read-only | The index of the subsystem to which this controller belongs. |
| STR cpqSMAControllerPort_1_Address | 1.3.6.1.4.1.232.151.100.3.1.1.29 | DisplayString | read-only | The Host_Port1 Address. |
| STR cpqSMAControllerPort_2_Address | 1.3.6.1.4.1.232.151.100.3.1.1.30 | DisplayString | read-only | The Host_Port2 Address. |
| STR cpqSMAControllerLogicalDiskIndexes | 1.3.6.1.4.1.232.151.100.3.1.1.31 | DisplayString | read-only | The indexes of all the logical disks associated with the controller. Each index is seperated by a ':' . |
| STR cpqSMAControllerSnapshotIndexes | 1.3.6.1.4.1.232.151.100.3.1.1.32 | DisplayString | read-only | The indexes of all the snapshots associated with the controller. Each index is seperated by a ':' . |
| cpqSMALogicalDisk | 1.3.6.1.4.1.232.151.100.4 | |||
| cpqSMALogicalDiskTable | 1.3.6.1.4.1.232.151.100.4.1 | not-accessible | The table of LogicalDisks | |
| cpqSMALogicalDiskEntry | 1.3.6.1.4.1.232.151.100.4.1.1 | not-accessible | A table entry for a LogicalDisk | |
| INT cpqSMALogicalDiskIndex | 1.3.6.1.4.1.232.151.100.4.1.1.1 | INTEGER | read-only | The LogicalDisk index. This is just a ordered sequence done by the agent, has no relationship to the unit offset or unit name/number. |
| STR cpqSMALogicalDiskName | 1.3.6.1.4.1.232.151.100.4.1.1.2 | DisplayString | read-only | The name of the LogicalDisk. |
| INT cpqSMALogicalDiskSize | 1.3.6.1.4.1.232.151.100.4.1.1.3 | INTEGER | read-only | Logical Drive Size. This is the size of the logical drive in blocks. One block equals 512 bytes (1 block = 512 bytes). |
| INT cpqSMALogicalDiskCreatedFromIndex | 1.3.6.1.4.1.232.151.100.4.1.1.4 | INTEGER | read-only | Logical Drive Created From Instance. This gives us the instance of the storageset or physical disk from which this LUN was created. |
| INT cpqSMALogicalDiskReadCache | 1.3.6.1.4.1.232.151.100.4.1.1.5 | INTEGER | read-only | Logical Drive Read Cache. The state of the read cache for the associated logical drives. |
| INT cpqSMALogicalDiskWriteBackCache | 1.3.6.1.4.1.232.151.100.4.1.1.6 | INTEGER | read-only | Logical Drive WriteBack Cache. The state of the writeback cache for the associated logical drives. |
| INT cpqSMALogicalDiskWriteProtectCache | 1.3.6.1.4.1.232.151.100.4.1.1.7 | INTEGER | read-only | Logical Drive WriteProtect Cache. The state of the write protect cache for the associated logical drives. |
| INT cpqSMALogicalDiskReadAheadCache | 1.3.6.1.4.1.232.151.100.4.1.1.8 | INTEGER | read-only | Logical Drive ReadAhead Cache. The state of the readahead cache for the associated logical drives. |
| INT cpqSMALogicalDiskRunState | 1.3.6.1.4.1.232.151.100.4.1.1.9 | INTEGER | read-only | Logical Drive Run State. The run state for the associated logical drives. you specify RUN to make a unit available to the host. |
| INT cpqSMALogicalDiskState | 1.3.6.1.4.1.232.151.100.4.1.1.10 | INTEGER | read-only | Logical Drive State. The state of the associated logical drive. |
| INT cpqSMALogicalDiskCachedTransferSize | 1.3.6.1.4.1.232.151.100.4.1.1.11 | INTEGER | read-only | Logical Drive CachedTransferSize. The largest number of write blocks to be cached by the controller. The controller will not cache any transfers over the specified size. |
| INT cpqSMALogicalDiskPreferredPath | 1.3.6.1.4.1.232.151.100.4.1.1.12 | INTEGER | read-only | Logical Drive PreferredPath. May be set only when dual redundant controllers are operating in a multiple-bus failover configuration. |
| STR cpqSMALogicalDiskHostAccess | 1.3.6.1.4.1.232.151.100.4.1.1.13 | DisplayString | read-only | Logical Drive Host Access. Specifies the access path. |
| STR cpqSMALogicalDiskIdentifier | 1.3.6.1.4.1.232.151.100.4.1.1.14 | DisplayString | read-only | Logical Drive ID (Lun_ID) This ID consists of the controller node ID plus a 64-bit unit ID generated by the subsystem. |
| INT cpqSMALogicalDiskHeads | 1.3.6.1.4.1.232.151.100.4.1.1.15 | INTEGER | read-only | Number of Heads. |
| INT cpqSMALogicalDiskCylinders | 1.3.6.1.4.1.232.151.100.4.1.1.16 | INTEGER | read-only | Number of Cylinders. |
| INT cpqSMALogicalDiskSectors | 1.3.6.1.4.1.232.151.100.4.1.1.17 | INTEGER | read-only | Number of Sectors. |
| INT cpqSMALogicalDiskControllerInstance | 1.3.6.1.4.1.232.151.100.4.1.1.18 | INTEGER | read-only | Logical Drive Controller Instance. This gives us the instance of the controller to which this LUN is online. |
| INT cpqSMALogicalDiskCreatedFromType | 1.3.6.1.4.1.232.151.100.4.1.1.19 | INTEGER | read-only | Logical Drive Created from type. Tells us whether the LUN was created from an entire physical disk, entire storageset or from a partition(logical or physical). cpqSMALogicalDiskCreatedFromIndex gives us the instance of the object. |
| INT cpqSMALogicalDiskIdentifierSwitch | 1.3.6.1.4.1.232.151.100.4.1.1.20 | INTEGER | read-only | Logical Drive Identifier switch. This is used with the SCSI_VERSION switch when the SCSI version is set to SCSI-3 mode. The IDENTIFIER switch creates a unique unit identifier makes the unit visible to the host.This number can be a value between 1-9999. The value 0 means NOIDENTIFIER. |
| INT cpqSMALogicalDiskSnapped | 1.3.6.1.4.1.232.151.100.4.1.1.21 | INTEGER | read-only | Logical Drive Snapped. This tells us if a snapshot of this disk exists. |
| INT cpqSMALogicalDiskSnapshotInstance | 1.3.6.1.4.1.232.151.100.4.1.1.22 | INTEGER | read-only | Logical Drive Snapshot instance. If the disk has a snapshot ie. cpqSMALogicalDiskSnapped is yes, then this gives us the instance of the snapshot else -1. |
| INT cpqSMALogicalDiskSubsystemIndex | 1.3.6.1.4.1.232.151.100.4.1.1.23 | INTEGER | read-only | The index of the subsystem where this logical disk resides. |
| cpqSMAPhysicalDisk | 1.3.6.1.4.1.232.151.100.5 | |||
| cpqSMAPhysicalDiskTable | 1.3.6.1.4.1.232.151.100.5.1 | not-accessible | The table of PhysicalDisks | |
| cpqSMAPhysicalDiskEntry | 1.3.6.1.4.1.232.151.100.5.1.1 | not-accessible | A table entry for a PhysicalDisk | |
| INT cpqSMAPhysicalDiskIndex | 1.3.6.1.4.1.232.151.100.5.1.1.1 | INTEGER | read-only | The PhysicalDisk index |
| STR cpqSMAPhysicalDiskName | 1.3.6.1.4.1.232.151.100.5.1.1.2 | DisplayString | read-only | The name of the PhysicalDisk. |
| STR cpqSMAPhysicalDiskModel | 1.3.6.1.4.1.232.151.100.5.1.1.3 | DisplayString | read-only | The model of the PhysicalDisk. |
| INT cpqSMAPhysicalDiskPort | 1.3.6.1.4.1.232.151.100.5.1.1.4 | INTEGER | read-only | The PhysicalDisk Port |
| INT cpqSMAPhysicalDiskTarget | 1.3.6.1.4.1.232.151.100.5.1.1.5 | INTEGER | read-only | The PhysicalDisk target |
| INT cpqSMAPhysicalDiskLun | 1.3.6.1.4.1.232.151.100.5.1.1.6 | INTEGER | read-only | The PhysicalDisk LUN |
| INT cpqSMAPhysicalDiskSize | 1.3.6.1.4.1.232.151.100.5.1.1.7 | INTEGER | read-only | Physical Disk Size. This is the size of the physical disk in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this value may differ from the advertised size of a drive. |
| INT cpqSMAPhysicalDiskTransportable | 1.3.6.1.4.1.232.151.100.5.1.1.8 | INTEGER | read-only | PhysicalDisk Transportable. Indicates whether a disk drive can be accessed exclusively by StorageWorks. |
| INT cpqSMAPhysicalDiskTransferRate | 1.3.6.1.4.1.232.151.100.5.1.1.9 | INTEGER | read-only | PhysicalDisk Transportable. Indicates whether a disk drive can be accessed exclusively by StorageWorks. |
| INT cpqSMAPhysicalDiskState | 1.3.6.1.4.1.232.151.100.5.1.1.10 | INTEGER | read-only | PhysicalDisk State. Indicates whether a disk drive has been assigend to a storageset, lun or not. |
| INT cpqSMAPhysicalDiskUsedByIndex | 1.3.6.1.4.1.232.151.100.5.1.1.11 | INTEGER | read-only | PhysicalDisk Used by index. This is the index of the lun or storageset that was created by using this physical disk. If the disk is unassigned or free ie. cpqSMAPhysicalDiskState = 1 then the index is of the this controller. |
| INT cpqSMAPhysicalDiskNoofPartitions | 1.3.6.1.4.1.232.151.100.5.1.1.12 | INTEGER | read-only | The number of partitions on this PhysicalDisk. |
| INT cpqSMAPhysicalDiskUsedByType | 1.3.6.1.4.1.232.151.100.5.1.1.13 | INTEGER | read-only | PhysicalDisk UsedByType. If this disk has been assigned ie. cpqSMAPhysicalDiskState = 2, then this indicates the type of object that was created using this disk ie. whether it is a storageset or a lun and cpqSMAPhysicalDiskUsedByIndex gives you the instance of that object. |
| INT cpqSMAPhysicalDiskSubsystemIndex | 1.3.6.1.4.1.232.151.100.5.1.1.14 | INTEGER | read-only | The index of the subsystem where this physical disk resides. |
| cpqSMAStorageSet | 1.3.6.1.4.1.232.151.100.6 | |||
| cpqSMAStorageSetTable | 1.3.6.1.4.1.232.151.100.6.1 | not-accessible | The table of StorageSets | |
| cpqSMAStorageSetEntry | 1.3.6.1.4.1.232.151.100.6.1.1 | not-accessible | A table entry for a StorageSet | |
| INT cpqSMAStorageSetIndex | 1.3.6.1.4.1.232.151.100.6.1.1.1 | INTEGER | read-only | The StorageSet index |
| STR cpqSMAStorageSetName | 1.3.6.1.4.1.232.151.100.6.1.1.2 | DisplayString | read-only | The name of the StorageSet. |
| INT cpqSMAStorageSetRaidType | 1.3.6.1.4.1.232.151.100.6.1.1.3 | INTEGER | read-only | The StorageSet Raid Type |
| INT cpqSMAStorageSetSize | 1.3.6.1.4.1.232.151.100.6.1.1.4 | INTEGER | read-only | Storageset Size. This is the size of the storagset disk in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this value may differ from the advertised size of a drive. |
| INT cpqSMAStorageSetPolicy | 1.3.6.1.4.1.232.151.100.6.1.1.5 | INTEGER | read-only | The StorageSet Policy switch. Sets the selection criteria the contoller uses to choose a replacement disk from the spareset. This policy only pertains to MIRRORSETs and RAIDSETs. For the other types it will be set to unknown. |
| INT cpqSMAStorageSetReconstruct | 1.3.6.1.4.1.232.151.100.6.1.1.6 | INTEGER | read-only | The StorageSet Reconstruct switch. Sets the speed at which the contoller reconstructs data ti a new RAIDset disk that replaces the failed disk. This policy only pertains to RAIDSETs. For the other types it will be set to unknown. |
| INT cpqSMAStorageSetCopy | 1.3.6.1.4.1.232.151.100.6.1.1.7 | INTEGER | read-only | The StorageSet Copy switch. Sets the speed at which the controller copies data to a new member from normal mirrorset members when data is being mirrored to the storageset's disk drives. This policy only pertains to MIRRORSETs. For the other types it will be set to unknown. |
| STR cpqSMAStorageSetReadSource | 1.3.6.1.4.1.232.151.100.6.1.1.8 | DisplayString | read-only | The Storageset ReadSource switch. Selects the mirrorset member used by the controller to satisfy a read request. The values will be either - disk-name (name of the specific member to which you want the controller to direct all read requests) - least_busy - round_robin This policy only pertains to MIRRORSETs. For the other types it will be set to unknown. |
| INT cpqSMAStorageSetAutospare | 1.3.6.1.4.1.232.151.100.6.1.1.9 | INTEGER | read-only | The StorageSet Autospare switch. With autospare enabled on a failedset, any new disk drive that is inserted into the PTL location of a failed dusk drive is automatically initialized and placed into the spareset. This policy only pertains to FAILEDSET. For the other types it will be set to unknown. |
| INT cpqSMAStorageSetChunkSize | 1.3.6.1.4.1.232.151.100.6.1.1.10 | INTEGER | read-only | The StorageSet ChunkSize switch. Specify a chunk size to control the stripesize used for RAIDsets and stripesets in blocks. This policy only pertains to RAIDSETs and STRIPESETs. For the other types it will be set to zero. |
| INT cpqSMAStorageSetNoOfDisks | 1.3.6.1.4.1.232.151.100.6.1.1.11 | INTEGER | read-only | The number of the physical disks that was used to create this StorageSet. |
| STR cpqSMAStorageSetDisksIndex | 1.3.6.1.4.1.232.151.100.6.1.1.12 | DisplayString | read-only | The indexes of the physical disks from which this StorageSet was created. Each index is seperated by a ':' . |
| INT cpqSMAStorageSetState | 1.3.6.1.4.1.232.151.100.6.1.1.13 | INTEGER | read-only | Storageset State. Indicates whether a lun has been created from the storageset. |
| INT cpqSMAStorageSetUsedByIndex | 1.3.6.1.4.1.232.151.100.6.1.1.14 | INTEGER | read-only | Storageset Used by index. This is the index of the lun or snapshot that was created from this storageset. If the storageset is unassigned or free ie. cpqSMAStorageSetState = 1 then the index is of the this controller. If the storageset has multiple (>1) partitions then the value is -1. |
| INT cpqSMAStorageSetNoofPartitions | 1.3.6.1.4.1.232.151.100.6.1.1.15 | INTEGER | read-only | The number of partitions on this Storageset. |
| INT cpqSMAStorageSetSubsystemIndex | 1.3.6.1.4.1.232.151.100.6.1.1.16 | INTEGER | read-only | The index of the subsystem where this storageset resides. |
| INT cpqSMAStorageSetUsedByType | 1.3.6.1.4.1.232.151.100.6.1.1.17 | INTEGER | read-only | Storageset Used by index. This tells us whether the type of disk created from this storageset is a lun or a snapshot. ie. if cpqSMAStorageSetState = 2 (assigned) then this tells you the type (lun or snapshot) and cpqSMAStorageSetUsedByIndex gives the index of that object. |
| cpqSMAPartition | 1.3.6.1.4.1.232.151.100.7 | |||
| cpqSMAPartitionTable | 1.3.6.1.4.1.232.151.100.7.1 | not-accessible | The table of Partitions | |
| cpqSMAPartitionEntry | 1.3.6.1.4.1.232.151.100.7.1.1 | not-accessible | A table entry for a Partition | |
| INT cpqSMAPartitionIndex | 1.3.6.1.4.1.232.151.100.7.1.1.1 | INTEGER | read-only | The Partition index |
| STR cpqSMAPartitionName | 1.3.6.1.4.1.232.151.100.7.1.1.2 | DisplayString | read-only | The name of the Partition. |
| INT cpqSMAPartitionNumber | 1.3.6.1.4.1.232.151.100.7.1.1.3 | INTEGER | read-only | The Partition number |
| INT cpqSMAPartitionDeviceIndex | 1.3.6.1.4.1.232.151.100.7.1.1.4 | INTEGER | read-only | The Partition Device Index. This is the index of the device (physical) or storageset (logical) from which this partition was created. |
| INT cpqSMAPartitionState | 1.3.6.1.4.1.232.151.100.7.1.1.5 | INTEGER | read-only | The Partition number |
| INT cpqSMAPartitionUsedByIndex | 1.3.6.1.4.1.232.151.100.7.1.1.6 | INTEGER | read-only | The Partition Used By Index. This is the index of the lun that was created from this partition. If the parition is unassigned or free ie. cpqSMAPartitionDeviceState = 1 then the index is of the this controller. |
| INT cpqSMAPartitionSize | 1.3.6.1.4.1.232.151.100.7.1.1.7 | INTEGER | read-only | Partition Size. This is the size of the partition in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this value may differ from the advertised size of a drive. |
| INT cpqSMAPartitionType | 1.3.6.1.4.1.232.151.100.7.1.1.8 | INTEGER | read-only | The type of Partition. If its a partition created from a device(disk) its a physical partition if its created from a storageset then its a logical partition. |
| INT cpqSMAPartitionSubsystemIndex | 1.3.6.1.4.1.232.151.100.7.1.1.9 | INTEGER | read-only | The index of the subsystem where this partition resides. |
| cpqSMAConnection | 1.3.6.1.4.1.232.151.100.8 | |||
| cpqSMAConnectionTable | 1.3.6.1.4.1.232.151.100.8.1 | not-accessible | The table of Connections | |
| cpqSMAConnectionEntry | 1.3.6.1.4.1.232.151.100.8.1.1 | not-accessible | A table entry for a Connection | |
| INT cpqSMAConnectionIndex | 1.3.6.1.4.1.232.151.100.8.1.1.1 | INTEGER | read-only | The Connection index |
| STR cpqSMAConnectionName | 1.3.6.1.4.1.232.151.100.8.1.1.2 | DisplayString | read-only | The name of the Connection. |
| STR cpqSMAConnectionOSName | 1.3.6.1.4.1.232.151.100.8.1.1.3 | DisplayString | read-only | The Operating System name. |
| INT cpqSMAConnectionController | 1.3.6.1.4.1.232.151.100.8.1.1.4 | INTEGER | read-only | The instance of the controller to which there is a connection. |
| INT cpqSMAConnectionControllerPortNumber | 1.3.6.1.4.1.232.151.100.8.1.1.5 | INTEGER | read-only | The port number on the controller to which there is a connection. |
| INT cpqSMAConnectionStatus | 1.3.6.1.4.1.232.151.100.8.1.1.6 | INTEGER | read-only | The status of connection. |
| INT cpqSMAConnectionOnlineTo | 1.3.6.1.4.1.232.151.100.8.1.1.7 | INTEGER | read-only | The instance of the controller to which it is online. |
| INT cpqSMAConnectionLunOffset | 1.3.6.1.4.1.232.151.100.8.1.1.8 | INTEGER | read-only | The LUN offset for this connection. |
| STR cpqSMAConnectionHostID | 1.3.6.1.4.1.232.151.100.8.1.1.9 | DisplayString | read-only | The HOST ID. |
| STR cpqSMAConnectionAdapterID | 1.3.6.1.4.1.232.151.100.8.1.1.10 | DisplayString | read-only | The Adapter ID. |
| STR cpqSMAConnectionUnitAddress | 1.3.6.1.4.1.232.151.100.8.1.1.11 | DisplayString | read-only | The Unit Address. |
| INT cpqSMAConnectionSubsystemIndex | 1.3.6.1.4.1.232.151.100.8.1.1.12 | INTEGER | read-only | The index of the subsystem where this connection exists. |
| cpqSMASnapshot | 1.3.6.1.4.1.232.151.100.9 | |||
| cpqSMASnapshotTable | 1.3.6.1.4.1.232.151.100.9.1 | not-accessible | The table of Snapshots | |
| cpqSMASnapshotEntry | 1.3.6.1.4.1.232.151.100.9.1.1 | not-accessible | A table entry for a Snapshot | |
| INT cpqSMASnapshotIndex | 1.3.6.1.4.1.232.151.100.9.1.1.1 | INTEGER | read-only | The Snapshot index |
| STR cpqSMASnapshotName | 1.3.6.1.4.1.232.151.100.9.1.1.2 | DisplayString | read-only | The name of the Snapshot. |
| INT cpqSMASnapshotSize | 1.3.6.1.4.1.232.151.100.9.1.1.3 | INTEGER | read-only | Snapshot Drive Size. This is the size of the snapshot in blocks. One block equals 512 bytes (1 block = 512 bytes). |
| INT cpqSMASnapshotCreatedFromIndex | 1.3.6.1.4.1.232.151.100.9.1.1.4 | INTEGER | read-only | Snapshot Created From Instance. This gives us the instance of the storageset from which this snapshot was created. |
| INT cpqSMASnapshotOf | 1.3.6.1.4.1.232.151.100.9.1.1.5 | INTEGER | read-only | This is the instance of the logical disk for which this is a snapshot. |
| INT cpqSMASnapshotState | 1.3.6.1.4.1.232.151.100.9.1.1.6 | INTEGER | read-only | Snapshot State. The state of the snapshot. |
| INT cpqSMASnapshotPreferredPath | 1.3.6.1.4.1.232.151.100.9.1.1.7 | INTEGER | read-only | Snapshot PreferredPath. May be set only when dual redundant controllers are operating in a multiple-bus failover configuration. |
| STR cpqSMASnapshotHostAccess | 1.3.6.1.4.1.232.151.100.9.1.1.8 | DisplayString | read-only | Snapshot Host Access. Specifies the access path. |
| STR cpqSMASnapshotIdentifier | 1.3.6.1.4.1.232.151.100.9.1.1.9 | DisplayString | read-only | Snapshot ID This ID consists of the controller node ID plus a 64-bit unit ID generated by the subsystem. |
| INT cpqSMASnapshotHeads | 1.3.6.1.4.1.232.151.100.9.1.1.10 | INTEGER | read-only | Number of Heads. |
| INT cpqSMASnapshotCylinders | 1.3.6.1.4.1.232.151.100.9.1.1.11 | INTEGER | read-only | Number of Cylinders. |
| INT cpqSMASnapshotSectors | 1.3.6.1.4.1.232.151.100.9.1.1.12 | INTEGER | read-only | Number of Sectors. |
| INT cpqSMASnapshotControllerInstance | 1.3.6.1.4.1.232.151.100.9.1.1.13 | INTEGER | read-only | Snapshot Controller Instance. This gives us the instance of the controller to which this snapshot is online. |
| INT cpqSMASnapshotIdentifierSwitch | 1.3.6.1.4.1.232.151.100.9.1.1.14 | INTEGER | read-only | Snapshot Identifier switch. This is used with the SCSI_VERSION switch when the SCSI version is set to SCSI-3 mode. The IDENTIFIER switch creates a unique unit identifier makes the unit visible to the host.This number can be a value between 1-9999. The value 0 means NOIDENTIFIER. |
| INT cpqSMASnapshotSubsystemIndex | 1.3.6.1.4.1.232.151.100.9.1.1.15 | INTEGER | read-only | The index of the subsystem where this snapshot resides. |
RFC description
Manages Compaq SAN (Storage Area Network) appliance components including controllers, disks, snapshots, and subsystem status monitoring.
Start monitoring Compaq/HP StorageWorks SAN Appliance (HSG80-based, legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.