CPQAPPG80-MIB :: cpqSMAStorageSetReconstruct

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › CPQAPPG80-MIB › cpqSMAStorageSetReconstruct

cpqSMAStorageSetReconstruct

Module: CPQAPPG80-MIB

OID (symbolic): CPQAPPG80-MIB::cpqSMAStorageSetReconstruct

OID (numeric): 1.3.6.1.4.1.232.151.100.6.1.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The StorageSet Reconstruct switch.

Sets the speed at which the contoller reconstructs data ti a new RAIDset disk that replaces the failed disk. This policy only pertains to RAIDSETs. For the other types it will be set to unknown.

What is cpqSMAStorageSetReconstruct?

This object reports the reconstruct speed setting of the storageset: fast(1), normal(2), or unknown(3), a setting that only pertains to raidsets and is set to unknown for other types. It controls how quickly the controller rebuilds data onto a replacement disk after a raidset member fails. An admin balancing rebuild time against production I/O performance would set this to normal to reduce impact on live workloads, or fast to minimize the window of reduced redundancy.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.151.100.6.1.1.6
snmpwalk -v2c -c public <target> CPQAPPG80-MIB::cpqSMAStorageSetReconstruct

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.151.100.6.1.1.6.1
snmpget -v2c -c public <target> CPQAPPG80-MIB::cpqSMAStorageSetReconstruct.1

Start monitoring Compaq/HP StorageWorks SAN Appliance (HSG80-based, legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQAPPG80-MIB::cpqSMAStorageSetReconstruct OID value, configure state conditions and alerts, and monitor any Compaq/HP StorageWorks SAN Appliance (HSG80-based, legacy) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.151cpqSanApplianceCPQAPPG80-MIB
1.3.6.1.4.1.232.151.100cpqsmav1CPQAPPG80-MIB
1.3.6.1.4.1.232.151.100.6cpqSMAStorageSetCPQAPPG80-MIB
1.3.6.1.4.1.232.151.100.6.1cpqSMAStorageSetTableCPQAPPG80-MIB
1.3.6.1.4.1.232.151.100.6.1.1cpqSMAStorageSetEntryCPQAPPG80-MIB
1.3.6.1.4.1.232.151.100.6.1.1.6cpqSMAStorageSetReconstructCPQAPPG80-MIB