cpqSMAControllerBatteryCheckState

Module: CPQAPPG80-MIB

OID (symbolic): CPQAPPG80-MIB::cpqSMAControllerBatteryCheckState

OID (numeric): 1.3.6.1.4.1.232.151.100.3.1.1.25

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Battery check state.

Specifies whether the controller should perform regular battery condition checks. If CACHE_UPS (ups) the controller does not check the condition of the cache batteries and ignores the battery's state. If NOCACHE_UPS (noups) the controller performs regular cache battery checks and evaluates the condition of the cache batteries.

What is cpqSMAControllerBatteryCheckState?

This object reports whether the controller performs regular cache battery condition checks: ups(1) means it does not check or evaluate the battery's state, while noups(2) means it actively performs regular checks and evaluates battery condition. An admin relying on the battery-backed cache to protect data during a power outage would want this set to noups so battery health is actively monitored. Seeing it set to ups when battery protection is expected would prompt the admin to review the controller's battery configuration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.151.100.3.1.1.25
snmpwalk -v2c -c public <target> CPQAPPG80-MIB::cpqSMAControllerBatteryCheckState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.151.100.3.1.1.25.1
snmpget -v2c -c public <target> CPQAPPG80-MIB::cpqSMAControllerBatteryCheckState.1

Start monitoring Compaq/HP StorageWorks SAN Appliance (HSG80-based, legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQAPPG80-MIB::cpqSMAControllerBatteryCheckState OID value, configure state conditions and alerts, and monitor any Compaq/HP StorageWorks SAN Appliance (HSG80-based, legacy) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.151cpqSanApplianceCPQAPPG80-MIB
1.3.6.1.4.1.232.151.100cpqsmav1CPQAPPG80-MIB
1.3.6.1.4.1.232.151.100.3cpqSMAControllerCPQAPPG80-MIB
1.3.6.1.4.1.232.151.100.3.1cpqSMAControllerTableCPQAPPG80-MIB
1.3.6.1.4.1.232.151.100.3.1.1cpqSMAControllerEntryCPQAPPG80-MIB
1.3.6.1.4.1.232.151.100.3.1.1.25cpqSMAControllerBatteryCheckStateCPQAPPG80-MIB