All MIBs › TELECOM-MIB
Category: Telecommunications Equipment
Description: Manages telecommunications equipment configuration, status, and operational parameters for generic telecom devices.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is TELECOM-MIB?
TELECOM-MIB is a vendor-oriented SNMP module for managing generic telecommunications equipment, exposing configuration, inventory, and status data for the chassis/agent and its installed modules. It covers device identification and inventory data (serial numbers, firmware/hardware versions per module) alongside chassis-level warning state and temperature. Its clearest monitoring value is in hardware health: matConWarningState and matConTemperature give a direct signal of thermal or fault conditions on the managed telecom chassis, while matAgentSoftwareVerison lets an operator confirm the running management agent's software version and matInvTable tracks per-module firmware/hardware versions for inventory and upgrade auditing. No explicit dependency on other standard MIBs is indicated in the available module text, suggesting a largely self-contained enterprise tree. It is typically deployed on branded telecom access or transport equipment where an NMS polls chassis temperature, warning flags, and module inventory as part of routine hardware health and asset-tracking checks. Administrators searching for mib telecom use this module to monitor telecom power-system controller, inverter, and dry-contact alarm status via SNMP.
IPNetwork Monitor allows you to monitor SNMP objects defined in TELECOM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- generic telecom access/transport equipment
- vendor telecom chassis with pluggable modules
Monitoring Examples
An administrator would poll matConTemperature and matConWarningState to catch a telecom chassis overheating or entering a warning condition before it causes a service outage. Walking matInvTable (via matInvModuleIndex, matInvSerialNum, matInvFirmwareVersion, matInvHardwareVersion) provides a per-slot inventory that can be diffed after a maintenance window to confirm firmware upgrades landed on the expected modules. matConSerialNum and matAgentSoftwareVerison together let the NMS uniquely identify the device and confirm it is running the expected management agent build.
What Can Be Monitored
- chassis temperature
- chassis warning state
- management agent software version
- per-module serial number
- per-module firmware version
- per-module hardware version
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| enterprises |
From SNMPv2-TC
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| device | 1.3.6.1.4.1.935.10 | |||
| matAgent | 1.3.6.1.4.1.935.10.2 | |||
| STR matAgentSoftwareVerison | 1.3.6.1.4.1.935.10.2.1.1.5 | DisplayString | read-only | The Network Management Card software/firmware version. |
| NTF matConBatteryLow | 1.3.6.1.4.1.935.10.2.2.0.87 | CRITICAL: Controller Battery Low. | ||
| NTF matConBatteryVoltHigh | 1.3.6.1.4.1.935.10.2.2.0.93 | CRITICAL: Controller Battery voltage high. | ||
| NTF matConCanBusOff | 1.3.6.1.4.1.935.10.2.2.0.95 | CRITICAL: Controller CAN bus off. | ||
| NTF matConCommunicationLost | 1.3.6.1.4.1.935.10.2.2.0.97 | CRITICAL: Controller communication lost. | ||
| NTF matConEEPROMFault | 1.3.6.1.4.1.935.10.2.2.0.91 | MAJOR: Controller EEPROM fault. | ||
| matConfig | 1.3.6.1.4.1.935.10.2.1.5 | |||
| NUM matConfInvInputVoltage | 1.3.6.1.4.1.935.10.2.1.2.2.1.20 | NonNegativeInteger | read-only | Rating Input voltage, the unit is 0.1 Volt. |
| NUM matConfInvOutputFreq | 1.3.6.1.4.1.935.10.2.1.2.2.1.24 | NonNegativeInteger | read-only | Rating output frequency, the unit is 0.1 Hz. |
| NUM matConfInvOutputPower | 1.3.6.1.4.1.935.10.2.1.2.2.1.23 | NonNegativeInteger | read-only | Rating output power, the unit is VA. |
| NUM matConfInvOutputVoltage | 1.3.6.1.4.1.935.10.2.1.2.2.1.19 | NonNegativeInteger | read-only | Rating Output voltage, the unit is 0.1 Volt. |
| NUM matConfInvOutputVoltHighLoss | 1.3.6.1.4.1.935.10.2.1.2.2.1.21 | NonNegativeInteger | read-only | Output High Loss voltage, the unit is 0.1 Volt. |
| NUM matConfInvOutputVoltLowLoss | 1.3.6.1.4.1.935.10.2.1.2.2.1.22 | NonNegativeInteger | read-only | Output Low loss voltage, the unit is 0.1 Volt. |
| INT matConfInvSysFanSpeed | 1.3.6.1.4.1.935.10.2.1.5.10 | INTEGER | read-write | Inverter System fan speed. |
| NUM matConfInvSysInputVolt | 1.3.6.1.4.1.935.10.2.1.5.5 | NonNegativeInteger | read-write | Inverter System Input Voltage, the unit is 0.1 Volt. This value depends on matConfInvInputVoltage: matConfInvInputVoltage(0.1V)=480: Range(400-440), matConfInvInputVoltage(0.1V)=600: Range(500-550) |
| NUM matConfInvSysLineVoltHighLoss | 1.3.6.1.4.1.935.10.2.1.5.7 | NonNegativeInteger | read-write | High loss for line voltage of 3.5k inverter module, the unit is 0.1 volt. This value depends on matConfInvSysOutputVolt, the least significant digit must be zero, see table: matConfInvSysOutputVolt(0.1V) Range(0.1V) 2080 2180-2650, 2200 2300-2650, 2300 2400-2650, 2400 2500-2650 |
| NUM matConfInvSysLineVoltLowLoss | 1.3.6.1.4.1.935.10.2.1.5.8 | NonNegativeInteger | read-write | Low loss for line voltage of 3.5k inverter module, the unit is 0.1 volt. This value depends on matConfInvSysOutputVolt, the least significant digit must be zero, see table: matConfInvSysOutputVolt(0.1V) Range(0.1V) 2080 1850-1980, 2200 1850-2100, 2300 1850-2200, 2400 1850-2300 |
| NUM matConfInvSysOutputFreq | 1.3.6.1.4.1.935.10.2.1.5.1 | NonNegativeInteger | read-write | Inverter system output frequency, can be 500 or 600, the unit is 0.1 Hz. |
| NUM matConfInvSysOutputVolt | 1.3.6.1.4.1.935.10.2.1.5.2 | NonNegativeInteger | read-write | Inverter system output voltage, can be 1100, 1150,1200,2080,2200,2300,2400. The unit is 0.1 Volt. |
| NUM matConfInvSysOutputVoltHighLoss | 1.3.6.1.4.1.935.10.2.1.5.3 | NonNegativeInteger | read-write | Output voltage high loss of Inverter System, the unit is 0.1 Volt. This value depends on matConfInvSysOutputVolt, the least significant digit must be zero, see table: matConfInvSysOutputVolt(0.1V) Range(0.1V) 1100 1170-1270, 1150 1220-1320, 1200 1270-1380, 2080 2200-2400, 2200 2330-2520, 2300 2440-2640, 2400 2540-2760 |
| NUM matConfInvSysOutputVoltLowLoss | 1.3.6.1.4.1.935.10.2.1.5.4 | NonNegativeInteger | read-write | Output Voltage Low Loss of inverter System, the unit is 0.1 volt. This value depends on matConfInvSysOutputVolt, the least significant digit must be zero, see table: matConfInvSysOutputVolt(0.1V) Range(0.1V) 1100 890-1050, 1150 930-1100, 1200 1000-1140, 2080 1760-1980, 2200 1760-2090, 2300 1850-2180, 2400 1930-2280 |
| NUM matConfInvSysPowerLimit | 1.3.6.1.4.1.935.10.2.1.5.6 | NonNegativeInteger | read-write | Inverter System Power Limited level, format: xxx, range: 50 to 100, the unit is percent. |
| INT matConfInvSysPriority | 1.3.6.1.4.1.935.10.2.1.5.9 | INTEGER | read-write | Priority for 3.5K inverter module. |
| NUM matConfStsAcVoltHighLoss | 1.3.6.1.4.1.935.10.2.1.5.11 | NonNegativeInteger | read-write | STS Module AC Voltage High Loss Volt, the unit is 0.1 volt. This value depends on matConfInvSysOutputVolt, the least significant digit must be zero, see table: matConfInvSysOutputVolt(0.1V) Range(0.1V) 1100 1170-1270, 1150 1220-1320, 1200 1270-1380, 2080 2200-2400, 2200 2330-2520, 2300 2440-2640, 2400 2540-2760 |
| NUM matConfStsAcVoltLowLoss | 1.3.6.1.4.1.935.10.2.1.5.12 | NonNegativeInteger | read-write | STS Module AC Voltage Low Loss Volt, the unit is 0.1 volt. This value depends on matConfInvSysOutputVolt, the least significant digit must be zero, see table: matConfInvSysOutputVolt(0.1V) Range(0.1V) 1100 890-1050, 1150 930-1100, 1200 1000-1140, 2080 1760-1980, 2200 1760-2090, 2300 1850-2180, 2400 1930-2280 |
| INT matConfStsFanSpeed | 1.3.6.1.4.1.935.10.2.1.5.16 | INTEGER | read-write | STS fan speed. |
| NUM matConfStsIpvVoltHighLoss | 1.3.6.1.4.1.935.10.2.1.5.13 | NonNegativeInteger | read-write | STS module Inverter IPV High Loss Volt, the unit is 0.1 volt. This value depends on matConfInvSysOutputVolt, the least significant digit must be zero, see table: matConfInvSysOutputVolt(0.1V) Range(0.1V) 1100 1170-1270, 1150 1220-1320, 1200 1270-1380, 2080 2200-2400, 2200 2330-2520, 2300 2440-2640, 2400 2540-2760 |
| NUM matConfStsIpvVoltLowLoss | 1.3.6.1.4.1.935.10.2.1.5.14 | NonNegativeInteger | read-write | STS module Inverter IPV low Loss Volt, the unit is 0.1 volt. This value depends on matConfInvSysOutputVolt, the least significant digit must be zero, see table: matConfInvSysOutputVolt(0.1V) Range(0.1V) 1100 890-1050, 1150 930-1100, 1200 1000-1140, 2080 1760-1980, 2200 1760-2090, 2300 1850-2180, 2400 1930-2280 |
| INT matConfStsPriority | 1.3.6.1.4.1.935.10.2.1.5.15 | INTEGER | read-write | STS output priority. |
| STR matConName | 1.3.6.1.4.1.935.10.2.1.1.2 | DisplayString | read-only | Power system name. |
| STR matConSerialNum | 1.3.6.1.4.1.935.10.2.1.1.1 | DisplayString | read-only | Controller serial number. |
| INT matConTemperature | 1.3.6.1.4.1.935.10.2.1.1.4 | INTEGER | read-only | Temperature of the controller, the unit is 0.1 degree. |
| NTF matConTemperatureHigh | 1.3.6.1.4.1.935.10.2.2.0.89 | CRITICAL: Controller temperature High. | ||
| matController | 1.3.6.1.4.1.935.10.2.1.1 | |||
| STR matConWarningState | 1.3.6.1.4.1.935.10.2.1.1.3 | DisplayString | read-only | The values indicate the unrestored traps. For example, if 'Controller Battery Low' and 'Controller temperature High' the agent send the trap 85 and trap 87 to NMS, so the value of matConWarningState should be '85,87'. And then the two events restored, the value of matConWarningState should change to empty. |
| matDryContact | 1.3.6.1.4.1.935.10.2.1.4 | |||
| matDryContactEntry | 1.3.6.1.4.1.935.10.2.1.4.2.1 | not-accessible | An entry containing information of one dry contact. | |
| NUM matDryContactIndex | 1.3.6.1.4.1.935.10.2.1.4.2.1.1 | PositiveInteger | not-accessible | The index of dry contact. |
| INT matDryContactNum | 1.3.6.1.4.1.935.10.2.1.4.1 | INTEGER | read-only | The number of dry contact. |
| STR matDryContactString | 1.3.6.1.4.1.935.10.2.1.4.2.1.2 | DisplayString | read-write | format: xx xx xx xx xx xx xx xx xx xx, xx: alarm code. If the configured alarm is less than 10, then fill the position with '--' to instead 'xx'. Alarm code: Inverter fault 0x01(for 3.5Kva system and 1.5Kva system), Inverter over load 0x02(for 3.5Kva system and 1.5Kva system), Inverter fan fault 0x03(for 3.5Kva system and 1.5Kva system), Inverter power limit 0x04(for 3.5Kva system and 1.5Kva system), Inverter DC input Abnormal 0x05(for 3.5Kva system and 1.5Kva system), Inverter low volt off 0x06(for 3.5Kva system and 1.5Kva system), Inverter lost 0x07(for 3.5Kva system and 1.5Kva system), Inverter Mains unavailable 0x19(for 3.5Kva system), Inverter Maintenance Bypass 0x1A(for 3.5Kva system), Inverter Output 0x1B(for 3.5Kva system), STS Inv unavailable 0x2A(for 1.5Kva system), STS Main unavailable 0x2B(for 1.5Kva system), STS Output overload 0x2C(for 1.5Kva system), STS OP Short circuit 0x2D(for 1.5Kva system), STS K1 Relay open 0x23(for 1.5Kva system), STS SCR1 short 0x24(for 1.5Kva system), STS SCR2 short 0x25(for 1.5Kva system), STS INV Bypass Mode 0x2F(for 1.5Kva system), STS Over temperature 0x30(for 1.5Kva system), STS MBS Abnormal 0x31(for 1.5Kva system), STS Fan Lock 0x27(for 1.5Kva system), STS Fault Mode 0x26(for 1.5Kva system), STS Eeprom Fault 0x28(for 1.5Kva system), SPS Power Fail 0x32(for 1.5Kva system), STS Output abnormal 0x34(for 1.5Kva system), STS Maintenance Bypass 0x35(for 1.5Kva system), STS Output 0x36(for 1.5Kva system), Controller temperature high 0x42(for 3.5Kva system and 1.5Kva system), Controller eeprom fail 0x43(for 3.5Kva system and 1.5Kva system), Controller CAN Bus Off 0x45(for 3.5Kva system and 1.5Kva system) |
| matDryContactTable | 1.3.6.1.4.1.935.10.2.1.4.2 | not-accessible | This table list dry contact message. | |
| NTF matInvBackfeedRelayOpen | 1.3.6.1.4.1.935.10.2.2.0.43 | CRITICAL: Inverter Backfeed Relay Open. | ||
| NUM matInvBatteryVoltage | 1.3.6.1.4.1.935.10.2.1.2.2.1.8 | NonNegativeInteger | read-only | Inverter Battery voltage, the unit is 0.1 Volt. |
| NTF matInvBusSoftFail | 1.3.6.1.4.1.935.10.2.2.0.19 | CRITICAL: Inverter Bus Soft Start Fail. | ||
| NTF matInvBusVoltageOverLimit | 1.3.6.1.4.1.935.10.2.2.0.15 | CRITICAL: Inverter Bus voltage over the maximal level. | ||
| NTF matInvBusVoltageUnderLimit | 1.3.6.1.4.1.935.10.2.2.0.17 | CRITICAL: Inverter Bus volt under the minimal level. | ||
| NTF matInvBypassSCRShort | 1.3.6.1.4.1.935.10.2.2.0.39 | CRITICAL: Inverter Bypass SCR Short. | ||
| NTF matInvEEPROMFault | 1.3.6.1.4.1.935.10.2.2.0.37 | MAJOR: Inverter EEPROM fault. | ||
| matInvEntry | 1.3.6.1.4.1.935.10.2.1.2.2.1 | not-accessible | An entry containing information applicable to a particular Inverter module. | |
| NTF matInvEPOShutdown | 1.3.6.1.4.1.935.10.2.2.0.33 | CRITICAL: Inverter EPO shutdown. | ||
| matInverter | 1.3.6.1.4.1.935.10.2.1.2 | |||
| NTF matInvFanFault | 1.3.6.1.4.1.935.10.2.2.0.5 | MAJOR: Inverter Fan fault. | ||
| NTF matInvFault | 1.3.6.1.4.1.935.10.2.2.0.1 | MAJOR: Inverter fault. | ||
| STR matInvFirmwareVersion | 1.3.6.1.4.1.935.10.2.1.2.2.1.3 | DisplayString | read-only | Firmware version. |
| NTF matInvHardwareError | 1.3.6.1.4.1.935.10.2.2.0.45 | CRITICAL: Inverter Hardware Detection Error. | ||
| STR matInvHardwareVersion | 1.3.6.1.4.1.935.10.2.1.2.2.1.4 | DisplayString | read-only | Hardware version. |
| NTF matInvInputAbnormal | 1.3.6.1.4.1.935.10.2.2.0.9 | MAJOR: Inverter input abnormal. | ||
| NUM matInvLineFreq | 1.3.6.1.4.1.935.10.2.1.2.2.1.15 | NonNegativeInteger | read-only | Line frequency of 3.5K, the unit is 0.1 Hz. |
| NUM matInvLineVoltage | 1.3.6.1.4.1.935.10.2.1.2.2.1.14 | NonNegativeInteger | read-only | Line voltage of 3.5K, the unit is 0.1 Volt. |
| NTF matInvLowInputShutdown | 1.3.6.1.4.1.935.10.2.2.0.11 | MAJOR: Inverter shut down due to low input voltage. | ||
| NTF matInvMaintenaceBypass | 1.3.6.1.4.1.935.10.2.2.0.49 | MAJOR: Inverter Maintenance Bypass. | ||
| NTF matInvMainUnavailable | 1.3.6.1.4.1.935.10.2.2.0.47 | MAJOR: Inverter Mains Unavailable. | ||
| NTF matInvMBSPosError | 1.3.6.1.4.1.935.10.2.2.0.41 | CRITICAL: Inverter MBS Position Error. | ||
| INT matInvMbsPosition | 1.3.6.1.4.1.935.10.2.1.2.2.1.16 | INTEGER | read-only | MBS position of 3.5K. |
| NUM matInvModuleIndex | 1.3.6.1.4.1.935.10.2.1.2.2.1.1 | PositiveInteger | not-accessible | The index of Inverter module. |
| INT matInvModuleNum | 1.3.6.1.4.1.935.10.2.1.2.1 | INTEGER | read-only | The number of Inverter modules. |
| NTF matInvNegativePowerProtect | 1.3.6.1.4.1.935.10.2.2.0.29 | CRITICAL: Inverter negative power protection. | ||
| NTF matInvNotRespond | 1.3.6.1.4.1.935.10.2.2.0.13 | CRITICAL: Inverter disconnected. | ||
| INT matInvOnOffStatus | 1.3.6.1.4.1.935.10.2.1.2.2.1.26 | INTEGER | read-write | Inverter module On/Off status. |
| NUM matInvOutputCurrent | 1.3.6.1.4.1.935.10.2.1.2.2.1.7 | NonNegativeInteger | read-only | Inverter Output Current, unit is 0.1 amp. |
| NUM matInvOutputFreq | 1.3.6.1.4.1.935.10.2.1.2.2.1.9 | NonNegativeInteger | read-only | Output frequency, the unit is 0.1 Hz. |
| NUM matInvOutputPower | 1.3.6.1.4.1.935.10.2.1.2.2.1.10 | NonNegativeInteger | read-only | Output power, the unit is VA. |
| NTF matInvOutputShort | 1.3.6.1.4.1.935.10.2.2.0.21 | CRITICAL: Inverter Output Short. | ||
| NUM matInvOutputVoltage | 1.3.6.1.4.1.935.10.2.1.2.2.1.6 | NonNegativeInteger | read-only | Inverter Output Voltage, the unit is 0.1 Volt. |
| NTF matInvOutputVoltHigh | 1.3.6.1.4.1.935.10.2.2.0.25 | CRITICAL: Inverter output voltage high. | ||
| NTF matInvOutputVoltLow | 1.3.6.1.4.1.935.10.2.2.0.23 | CRITICAL: Inverter output voltage low. | ||
| NTF matInvOverLoad | 1.3.6.1.4.1.935.10.2.2.0.3 | MAJOR: Inverter Over-loading. | ||
| INT matInvPhaseType | 1.3.6.1.4.1.935.10.2.1.2.2.1.25 | INTEGER | read-only | Phase type. |
| NUM matInvPowerLimit | 1.3.6.1.4.1.935.10.2.1.2.2.1.11 | NonNegativeInteger | read-only | Power Limit Status of Inverter module, the unit is percent. |
| INT matInvPriority | 1.3.6.1.4.1.935.10.2.1.2.2.1.18 | INTEGER | read-only | Priority of 3.5K. |
| NTF matInvPulseFault | 1.3.6.1.4.1.935.10.2.2.0.31 | CRITICAL: Inverter Sync Pulse Fault. | ||
| INT matInvRunMode | 1.3.6.1.4.1.935.10.2.1.2.2.1.17 | INTEGER | read-only | Currently run mode of 3.5K. |
| NUM matInvRunTime | 1.3.6.1.4.1.935.10.2.1.2.2.1.12 | NonNegativeInteger | read-only | Run time, the unit is Hour. |
| STR matInvSerialNum | 1.3.6.1.4.1.935.10.2.1.2.2.1.2 | DisplayString | read-only | Module serial number. |
| NTF matInvSoftStartFail | 1.3.6.1.4.1.935.10.2.2.0.35 | CRITICAL: Inverter soft start fail. | ||
| matInvTable | 1.3.6.1.4.1.935.10.2.1.2.2 | not-accessible | This table list Inverter message. | |
| INT matInvTemperature | 1.3.6.1.4.1.935.10.2.1.2.2.1.13 | INTEGER | read-only | Temperature of the inverter, the unit is 0.1 degree. |
| NTF matInvTemperatureHigh | 1.3.6.1.4.1.935.10.2.2.0.27 | CRITICAL: Inverter Temperature High. | ||
| NTF matInvTempPowerLimit | 1.3.6.1.4.1.935.10.2.2.0.7 | MAJOR: Inverter power limit. | ||
| STR matInvWarningState | 1.3.6.1.4.1.935.10.2.1.2.2.1.5 | DisplayString | read-only | The values indicate the unrestored traps. For example, if 'Inverter fault' and 'Inverter Over-loading' the agent send the trap 1 and trap 3 to NMS, so the value of matConWarningState should be '1,3'. And then the two events restored, the value of matConWarningState should change to empty. |
| matObjects | 1.3.6.1.4.1.935.10.2.1 | |||
| NTF matReturnFromCommunicationLost | 1.3.6.1.4.1.935.10.2.2.0.98 | OBSERVE: Return from Controller communication lost. | ||
| NTF matReturnFromConBatteryLow | 1.3.6.1.4.1.935.10.2.2.0.88 | OBSERVE: Return from Controller Battery Low. | ||
| NTF matReturnFromConBatteryVoltHigh | 1.3.6.1.4.1.935.10.2.2.0.94 | OBSERVE: Return from Controller Battery voltage high. | ||
| NTF matReturnFromConCanBusOff | 1.3.6.1.4.1.935.10.2.2.0.96 | OBSERVE: Return from Controller CAN bus off. | ||
| NTF matReturnFromConEEPROMFault | 1.3.6.1.4.1.935.10.2.2.0.92 | OBSERVE: Return from Controller EEPROM fault. | ||
| NTF matReturnFromConTemperatureHigh | 1.3.6.1.4.1.935.10.2.2.0.90 | OBSERVE: Return from Controller temperature High. | ||
| NTF matReturnFromInvBackfeedRelayOpen | 1.3.6.1.4.1.935.10.2.2.0.44 | OBSERVE: Return from Inverter Backfeed Relay Open. | ||
| NTF matReturnFromInvBusSoftFail | 1.3.6.1.4.1.935.10.2.2.0.20 | OBSERVE: Return from Inverter Bus Soft Start Fail. | ||
| NTF matReturnFromInvBusVoltOverLimit | 1.3.6.1.4.1.935.10.2.2.0.16 | OBSERVE: Return from Inverter Bus voltage over the maximal level. | ||
| NTF matReturnFromInvBusVoltUnderLimit | 1.3.6.1.4.1.935.10.2.2.0.18 | OBSERVE: Return from Inverter Bus volt under the minimal level. | ||
| NTF matReturnFromInvBypassSCRShort | 1.3.6.1.4.1.935.10.2.2.0.40 | OBSERVE: Return from Inverter Bypass SCR Short. | ||
| NTF matReturnFromInvEEPROMFault | 1.3.6.1.4.1.935.10.2.2.0.38 | OBSERVE: Return from Inverter EEPROM fault. | ||
| NTF matReturnFromInvEPOShutdown | 1.3.6.1.4.1.935.10.2.2.0.34 | OBSERVE: Return from Inverter EPO shutdown. | ||
| NTF matReturnFromInvFanFault | 1.3.6.1.4.1.935.10.2.2.0.6 | OBSERVE: Return from Inverter Fan fault. | ||
| NTF matReturnFromInvFault | 1.3.6.1.4.1.935.10.2.2.0.2 | OBSERVE: Return from Inverter fault. | ||
| NTF matReturnFromInvHardwareError | 1.3.6.1.4.1.935.10.2.2.0.46 | OBSERVE: Return from Inverter Hardware Detection Error. | ||
| NTF matReturnFromInvInputAbnormal | 1.3.6.1.4.1.935.10.2.2.0.10 | OBSERVEReturn from Inverter input abnormal. | ||
| NTF matReturnFromInvLowInputShutdown | 1.3.6.1.4.1.935.10.2.2.0.12 | OBSERVE: Return from Inverter shut down due to low input voltage. | ||
| NTF matReturnFromInvMaintenaceBypass | 1.3.6.1.4.1.935.10.2.2.0.50 | OBSERVE: Return from Inverter Maintenance Bypass. | ||
| NTF matReturnFromInvMainUnavailable | 1.3.6.1.4.1.935.10.2.2.0.48 | OBSERVE: Return from Inverter Mains Unavailable. | ||
| NTF matReturnFromInvMBSPosError | 1.3.6.1.4.1.935.10.2.2.0.42 | OBSERVE: Return from Inverter MBS Position Error. | ||
| NTF matReturnFromInvNegativePowerProtect | 1.3.6.1.4.1.935.10.2.2.0.30 | OBSERVE: Return from Inverter negative power protection. | ||
| NTF matReturnFromInvNotRespond | 1.3.6.1.4.1.935.10.2.2.0.14 | OBSERVE: Inverter connected. | ||
| NTF matReturnFromInvOutputShort | 1.3.6.1.4.1.935.10.2.2.0.22 | OBSERVE: Return from Inverter Output Short. | ||
| NTF matReturnFromInvOutputVoltHigh | 1.3.6.1.4.1.935.10.2.2.0.26 | OBSERVE: Return from Inverter output voltage high. | ||
| NTF matReturnFromInvOutputVoltLow | 1.3.6.1.4.1.935.10.2.2.0.24 | OBSERVE: Return from Inverter output voltage low. | ||
| NTF matReturnFromInvOverLoad | 1.3.6.1.4.1.935.10.2.2.0.4 | OBSERVE: Return from Inverter Over-loading. | ||
| NTF matReturnFromInvPulseFault | 1.3.6.1.4.1.935.10.2.2.0.32 | OBSERVE: Return from Inverter Sync Pulse Fault. | ||
| NTF matReturnFromInvSoftStartFail | 1.3.6.1.4.1.935.10.2.2.0.36 | OBSERVE: Return from Inverter soft start fail. | ||
| NTF matReturnFromInvTemperatureHigh | 1.3.6.1.4.1.935.10.2.2.0.28 | OBSERVE: Return from Inverter Temperature High. | ||
| NTF matReturnFromInvTempPowerLimit | 1.3.6.1.4.1.935.10.2.2.0.8 | OBSERVE: Return from Inverter power limit. | ||
| NTF matReturnFromStsBackfeedRelayOpen | 1.3.6.1.4.1.935.10.2.2.0.54 | OBSERVE: Return from STS Back-feed relay open. | ||
| NTF matReturnFromStsBypassUnavailable | 1.3.6.1.4.1.935.10.2.2.0.52 | OBSERVE: Return from STS Bypass unavailable. | ||
| NTF matReturnFromStsControlPowerFail | 1.3.6.1.4.1.935.10.2.2.0.80 | OBSERVE: Return from STS Control power fail. | ||
| NTF matReturnFromStsEEPROMFault | 1.3.6.1.4.1.935.10.2.2.0.64 | OBSERVE: Return from STS EEPROM fault. | ||
| NTF matReturnFromStsFanFault | 1.3.6.1.4.1.935.10.2.2.0.62 | OBSERVE: Return from STS fan fault. | ||
| NTF matReturnFromStsFaultMode | 1.3.6.1.4.1.935.10.2.2.0.60 | OBSERVE: Return from STS running in fault mode. | ||
| NTF matReturnFromStsInvBypassMode | 1.3.6.1.4.1.935.10.2.2.0.74 | OBSERVE: Return from STS Inverter bypass mode. | ||
| NTF matReturnFromStsInvFail | 1.3.6.1.4.1.935.10.2.2.0.66 | OBSERVE: Return from STS Inverter unavailable. | ||
| NTF matReturnFromStsMainFail | 1.3.6.1.4.1.935.10.2.2.0.68 | OBSERVE: Return from STS Mains unavailable. | ||
| NTF matReturnFromStsMaintenanceBypass | 1.3.6.1.4.1.935.10.2.2.0.86 | OBSERVE: Return from STS Maintenance Bypass. | ||
| NTF matReturnFromStsMBSPosFault | 1.3.6.1.4.1.935.10.2.2.0.78 | OBSERVE: Return from STS MBS in abnormal position. | ||
| NTF matReturnFromStsNotRespond | 1.3.6.1.4.1.935.10.2.2.0.82 | OBSERVE: STS connected. | ||
| NTF matReturnFromStsOutputAbnormal | 1.3.6.1.4.1.935.10.2.2.0.84 | OBSERVE: Return from STS Output abnormal. | ||
| NTF matReturnFromStsOutputShortCircuit | 1.3.6.1.4.1.935.10.2.2.0.72 | OBSERVE: Return from STS Output short circuit. | ||
| NTF matReturnFromStsOverLoad | 1.3.6.1.4.1.935.10.2.2.0.70 | OBSERVE: Return from STS Output over load. | ||
| NTF matReturnFromStsScr1ShortCurcuit | 1.3.6.1.4.1.935.10.2.2.0.56 | OBSERVE: Return from STS SCR1 short circuit. | ||
| NTF matReturnFromStsScr2ShortCurcuit | 1.3.6.1.4.1.935.10.2.2.0.58 | OBSERVE: Return from STS SCR2 short circuit. | ||
| NTF matReturnFromStsTemperatureHigh | 1.3.6.1.4.1.935.10.2.2.0.76 | OBSERVE: Return from STS temperature high. | ||
| matSts | 1.3.6.1.4.1.935.10.2.1.3 | |||
| NTF matStsBackfeedRelayOpen | 1.3.6.1.4.1.935.10.2.2.0.53 | MAJOR: STS Back-feed relay open. | ||
| NTF matStsBypassUnavailable | 1.3.6.1.4.1.935.10.2.2.0.51 | MAJOR: STS Bypass unavailable. | ||
| NTF matStsControlPowerFail | 1.3.6.1.4.1.935.10.2.2.0.79 | CRITICAL: STS Control power fail. | ||
| NTF matStsEEPROMFault | 1.3.6.1.4.1.935.10.2.2.0.63 | MAJOR: STS EEPROM fault. | ||
| matStsEntry | 1.3.6.1.4.1.935.10.2.1.3.2.1 | not-accessible | An entry containing information applicable to a particular STS module. | |
| NTF matStsFanFault | 1.3.6.1.4.1.935.10.2.2.0.61 | MAJOR: STS fan fault. | ||
| NTF matStsFaultMode | 1.3.6.1.4.1.935.10.2.2.0.59 | CRITICAL: STS running in fault mode. | ||
| STR matStsFirmwareVersion | 1.3.6.1.4.1.935.10.2.1.3.2.1.4 | DisplayString | read-only | Firmware version. |
| STR matStsHardwareVersion | 1.3.6.1.4.1.935.10.2.1.3.2.1.5 | DisplayString | read-only | Hardware version. |
| NTF matStsInvBypassMode | 1.3.6.1.4.1.935.10.2.2.0.73 | CRITICAL: STS Inverter bypass mode. | ||
| NTF matStsInvFail | 1.3.6.1.4.1.935.10.2.2.0.65 | MAJOR: STS Inverter unavailable. | ||
| NUM matStsInvHighLossVoltage | 1.3.6.1.4.1.935.10.2.1.3.2.1.22 | NonNegativeInteger | read-only | STS Inverter high loss voltage, the unit is 0.1 volts. |
| NUM matStsInvInputFreq | 1.3.6.1.4.1.935.10.2.1.3.2.1.10 | NonNegativeInteger | read-only | STS INV I/P frequency, the unit is 0.1 Hz. |
| NUM matStsInvInputVoltage | 1.3.6.1.4.1.935.10.2.1.3.2.1.9 | NonNegativeInteger | read-only | STS INV I/P voltage, the unit is 0.1 volts. |
| NUM matStsInvLosLossVoltage | 1.3.6.1.4.1.935.10.2.1.3.2.1.23 | NonNegativeInteger | read-only | STS Inverter low loss voltage, the unit is 0.1 volts. |
| NUM matStsMainHighLossVoltage | 1.3.6.1.4.1.935.10.2.1.3.2.1.20 | NonNegativeInteger | read-only | STS Main high loss voltage, the unit is 0.1 volts. |
| NUM matStsMainInputFreq | 1.3.6.1.4.1.935.10.2.1.3.2.1.8 | NonNegativeInteger | read-only | STS Mains I/P frequency, the unit is 0.1 Hz. |
| NUM matStsMainInputVoltage | 1.3.6.1.4.1.935.10.2.1.3.2.1.7 | NonNegativeInteger | read-only | STS Mains I/P voltage, the unit is 0.1 Volts. |
| NUM matStsMainLowLossVoltage | 1.3.6.1.4.1.935.10.2.1.3.2.1.21 | NonNegativeInteger | read-only | STS Main low loss voltag, the unit is 0.1 volts. |
| NTF matStsMainsFail | 1.3.6.1.4.1.935.10.2.2.0.67 | MAJOR: STS Mains unavailable. | ||
| NTF matStsMaintenanceBypass | 1.3.6.1.4.1.935.10.2.2.0.85 | MAJOR: STS Maintenance Bypass. | ||
| NTF matStsMBSPosFault | 1.3.6.1.4.1.935.10.2.2.0.77 | CRITICAL: STS MBS in abnormal position. | ||
| INT matStsMbsStatus | 1.3.6.1.4.1.935.10.2.1.3.2.1.17 | INTEGER | read-only | STS MBS status. |
| NUM matStsModuleIndex | 1.3.6.1.4.1.935.10.2.1.3.2.1.1 | PositiveInteger | not-accessible | The index of STS module. |
| INT matStsModuleNum | 1.3.6.1.4.1.935.10.2.1.3.1 | INTEGER | read-only | The number of STS modules. |
| STR matStsModuleType | 1.3.6.1.4.1.935.10.2.1.3.2.1.2 | DisplayString | read-only | Module type, 050 represent 50A, 100 represent 100A. |
| NTF matStsNotRespond | 1.3.6.1.4.1.935.10.2.2.0.81 | CRITICAL: STS disconnected. | ||
| NTF matStsOutputAbnormal | 1.3.6.1.4.1.935.10.2.2.0.83 | MAJOR: STS Output abnormal. | ||
| NUM matStsOutputCurrent | 1.3.6.1.4.1.935.10.2.1.3.2.1.12 | NonNegativeInteger | read-only | STS O/P Current, the unit is 0.1 amp. |
| NUM matStsOutputFreq | 1.3.6.1.4.1.935.10.2.1.3.2.1.14 | NonNegativeInteger | read-only | STS O/P frequency, the unit is 0.1 Hz. |
| NUM matStsOutputPower | 1.3.6.1.4.1.935.10.2.1.3.2.1.13 | NonNegativeInteger | read-only | STS O/P Power, the unit is VA. |
| NTF matStsOutputShortCircuit | 1.3.6.1.4.1.935.10.2.2.0.71 | CRITICAL: STS Output short circuit. | ||
| NUM matStsOutputVoltage | 1.3.6.1.4.1.935.10.2.1.3.2.1.11 | NonNegativeInteger | read-only | STS O/P voltage, the unit is 0.1 volts. |
| NTF matStsOverLoad | 1.3.6.1.4.1.935.10.2.2.0.69 | MAJOR: STS Output over load. | ||
| INT matStsRunningMode | 1.3.6.1.4.1.935.10.2.1.3.2.1.19 | INTEGER | read-only | STS Running Mode. |
| NUM matStsRuntime | 1.3.6.1.4.1.935.10.2.1.3.2.1.15 | NonNegativeInteger | read-only | STS Runtime, the unit is Hour. |
| NTF matStsScr1ShortCurcuit | 1.3.6.1.4.1.935.10.2.2.0.55 | CRITICAL: STS SCR1 short circuit. | ||
| NTF matStsScr2ShortCurcuit | 1.3.6.1.4.1.935.10.2.2.0.57 | CRITICAL: STS SCR2 short circuit. | ||
| STR matStsSerialNum | 1.3.6.1.4.1.935.10.2.1.3.2.1.3 | DisplayString | read-only | Module serial number. |
| INT matStsStatus | 1.3.6.1.4.1.935.10.2.1.3.2.1.18 | INTEGER | read-only | STS status. |
| matStsTable | 1.3.6.1.4.1.935.10.2.1.3.2 | not-accessible | This table list STS message. | |
| INT matStsTemperature | 1.3.6.1.4.1.935.10.2.1.3.2.1.16 | INTEGER | read-only | STS module's Temperature, the unit is 0.1 degree. |
| NTF matStsTemperatureHigh | 1.3.6.1.4.1.935.10.2.2.0.75 | MAJOR: STS temperature high. | ||
| STR matStsWarningState | 1.3.6.1.4.1.935.10.2.1.3.2.1.6 | DisplayString | read-only | The values indicate the unrestored traps. For example, if 'STS running in fault mode' and 'STS fan fault' the agent send the trap 59 and trap 61 to NMS, so the value of matConWarningState should be '59,61'. And then the two events restored, the value of matConWarningState should change to empty. |
| matTraps | 1.3.6.1.4.1.935.10.2.2 | |||
| INT matTrapSeverityLevel | 1.3.6.1.4.1.935.10.2.1.6.2.1.5 | INTEGER | read-write | The severity level of traps to be received by this manager. |
| matTrapTargets | 1.3.6.1.4.1.935.10.2.1.6 | |||
| STR matTrapTargetsAddress | 1.3.6.1.4.1.935.10.2.1.6.2.1.2 | DisplayString | read-write | The IP address of the manager to send a trap to. |
| STR matTrapTargetsCommunity | 1.3.6.1.4.1.935.10.2.1.6.2.1.3 | DisplayString | read-write | The community name to use in the trap when sent to the manager. |
| STR matTrapTargetsDesc | 1.3.6.1.4.1.935.10.2.1.6.2.1.6 | DisplayString | read-write | Description of trap receivers |
| matTrapTargetsEntry | 1.3.6.1.4.1.935.10.2.1.6.2.1 | not-accessible | An entry containing information of one trap target. | |
| NUM matTrapTargetsIndex | 1.3.6.1.4.1.935.10.2.1.6.2.1.1 | PositiveInteger | not-accessible | The index to a trap receiver entry |
| INT matTrapTargetsNum | 1.3.6.1.4.1.935.10.2.1.6.1 | INTEGER | read-only | The number of trap targets. |
| matTrapTargetsTable | 1.3.6.1.4.1.935.10.2.1.6.2 | not-accessible | This table list the managers'IP to send traps to. | |
| INT matTrapType | 1.3.6.1.4.1.935.10.2.1.6.2.1.4 | INTEGER | read-write | The type of trap to be received by the manager. |
| ppc | 1.3.6.1.4.1.935 |
RFC description
Telecom device management MIB for monitoring power systems, controllers, inverters, and dry contacts.
Start monitoring generic telecom access/transport equipment, vendor telecom chassis with pluggable modules (chassis temperature/warning/module-inventory status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.