All MIBs › PDU-MIB
Organization: Raritan
Last Updated: 2016-02-22
Category: Power Management
Description: Manages Raritan intelligent PDU power distribution units, providing per-outlet switching, current, voltage, and power measurements.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is PDU-MIB?
PDU-MIB is a vendor-specific MIB from Raritan for its Dominion PX line of intelligent power distribution units (PDUs), rack-mounted devices that distribute and monitor AC power to connected equipment. It exposes hardware identity/configuration data (firmware version, serial number, IP address, netmask, gateway, MAC address, hardware revision) along with per-outlet/board power measurements and user/group access configuration. As a hardware/software status MIB it is used heavily for monitoring: firmwareVersion and hardwareRev indicate the unit's software/hardware baseline, board-level power objects reveal overload conditions, and trap objects surface fault events such as threshold breaches. It is a self-contained Raritan proprietary MIB but conceptually parallels other vendor PDU MIBs and can coexist with standard entity/physical MIBs for board-level inventory, given its board object. It is typically deployed in data centers and server rooms where Raritan Dominion PX PDUs provide remote power monitoring and per-outlet control for racks of servers and network equipment. Network engineers evaluating or troubleshooting this functionality can download the PDU-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in PDU-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Raritan Dominion PX intelligent PDU
Monitoring Examples
An administrator would poll firmwareVersion and hardwareRev to confirm the PDU is on a supported firmware/hardware baseline, and check ipAddress, netmask, and gateway to verify management network configuration after a redeploy. Board-level power objects (under the board object) would be monitored to detect an overloaded circuit or a failing outlet, and the traps object would notify the NMS of threshold-crossing power events.
What Can Be Monitored
- firmware version and hardware revision
- management IP/network configuration
- per-outlet/board current, voltage, and power draw
- user/group access configuration
- power threshold trap events
This MIB depends on
Related MIBs
Imported Objects
From INET-ADDRESS-MIB
| InetAddress | |
| InetAddressType |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 | |
| enterprises |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| MacAddress | |
| TEXTUAL-CONVENTION | |
| TruthValue |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| raritan | 1.3.6.1.4.1.13742 | This mib describes the SNMP functions of the Dominion PX Power Distribution Unit by Raritan Computer. | ||
| pdu | 1.3.6.1.4.1.13742.4 | |||
| traps | 1.3.6.1.4.1.13742.4.0 | |||
| NTF rebootStarted | 1.3.6.1.4.1.13742.4.0.1 | The reboot process has started | ||
| NTF rebootCompleted | 1.3.6.1.4.1.13742.4.0.2 | The reboot process is complete | ||
| NTF userLogin | 1.3.6.1.4.1.13742.4.0.3 | A user logged in | ||
| NTF userLogout | 1.3.6.1.4.1.13742.4.0.4 | A user logged out | ||
| NTF userAuthenticationFailure | 1.3.6.1.4.1.13742.4.0.5 | A user authentication attempt failed | ||
| NTF userSessionTimeout | 1.3.6.1.4.1.13742.4.0.8 | A user timed out from the device | ||
| NTF userAdded | 1.3.6.1.4.1.13742.4.0.11 | A user was added to the system | ||
| NTF userModified | 1.3.6.1.4.1.13742.4.0.12 | A user account was modified | ||
| NTF userDeleted | 1.3.6.1.4.1.13742.4.0.13 | A user was deleted from the system | ||
| NTF groupAdded | 1.3.6.1.4.1.13742.4.0.14 | A group was added to the system | ||
| NTF groupModified | 1.3.6.1.4.1.13742.4.0.15 | A group was modified | ||
| NTF groupDeleted | 1.3.6.1.4.1.13742.4.0.16 | A group was deleted from the system | ||
| NTF deviceUpdateStarted | 1.3.6.1.4.1.13742.4.0.20 | The device update has started | ||
| NTF userBlocked | 1.3.6.1.4.1.13742.4.0.22 | A blocked user tried to log in | ||
| NTF powerControl | 1.3.6.1.4.1.13742.4.0.23 | An outlet has been switched | ||
| NTF userPasswordChanged | 1.3.6.1.4.1.13742.4.0.24 | A user password was changed | ||
| NTF passwordSettingsChanged | 1.3.6.1.4.1.13742.4.0.28 | Strong password settings changed | ||
| NTF firmwareFileDiscarded | 1.3.6.1.4.1.13742.4.0.36 | A firmware file discarded | ||
| NTF firmwareValidationFailed | 1.3.6.1.4.1.13742.4.0.38 | A firmware validation failed | ||
| NTF securityViolation | 1.3.6.1.4.1.13742.4.0.39 | Security violation. | ||
| NTF logFileCleared | 1.3.6.1.4.1.13742.4.0.41 | The log file has been cleared. | ||
| NTF thresholdAlarm | 1.3.6.1.4.1.13742.4.0.45 | Configured sensor theshold event. The 'thresholdEventType' variable will indicate whether or not the threshold triggered or cleared. thresholdValue and sensorValue have valid values only for external temperature and humidity sensors. | ||
| NTF outletGroupingConnectivityLost | 1.3.6.1.4.1.13742.4.0.50 | Master PDU lost contact with the slave PDU in an outlet grouping configuration. | ||
| NTF circuitBreakerTripped | 1.3.6.1.4.1.13742.4.0.51 | Circuit Breaker Tripped. | ||
| NTF circuitBreakerRecovered | 1.3.6.1.4.1.13742.4.0.52 | Circuit Breaker Recovered. | ||
| NTF bulkConfigurationSaved | 1.3.6.1.4.1.13742.4.0.53 | Bulk Configuration saved. | ||
| NTF bulkConfigurationCopied | 1.3.6.1.4.1.13742.4.0.54 | Bulk Configuration saved. | ||
| NTF environmentalSensorsConnectivityLost | 1.3.6.1.4.1.13742.4.0.55 | lost connectivity to environmental Sensors | ||
| NTF externalOnOffSensorStateChange | 1.3.6.1.4.1.13742.4.0.56 | External OnOff Sensor State Change. | ||
| NTF environmentalSensorsConnectivityRestored | 1.3.6.1.4.1.13742.4.0.57 | connectivity to environmental Sensor was restored | ||
| NTF voltageMeasurementError | 1.3.6.1.4.1.13742.4.0.58 | voltage measurement error, a Psoc (Outlet Controller) reported zero voltage and non-zero current. Voltage, power and energy measurements may be in error | ||
| NTF fipsModeEnabled | 1.3.6.1.4.1.13742.4.0.59 | FIPS Mode Enabled | ||
| NTF fipsModeDisabled | 1.3.6.1.4.1.13742.4.0.60 | FIPS Mode Disabled | ||
| NTF managingenvironmentalSensor | 1.3.6.1.4.1.13742.4.0.61 | begin managing environmental Sensor | ||
| NTF unmanagingenvironmentalSensor | 1.3.6.1.4.1.13742.4.0.62 | cease managing environmental Sensor | ||
| NTF ipmiOverLANEnabled | 1.3.6.1.4.1.13742.4.0.63 | IPMI Over LAN Mode has been Enabled | ||
| NTF ipmiOverLANDisabled | 1.3.6.1.4.1.13742.4.0.64 | IPMI Over LAN Mode has been Disabled | ||
| board | 1.3.6.1.4.1.13742.4.1 | |||
| info | 1.3.6.1.4.1.13742.4.1.1 | |||
| STR firmwareVersion | 1.3.6.1.4.1.13742.4.1.1.1 | DisplayString | read-only | The current firmware version in the following format: major.minor.dot.buildnumber. Example: 1.3.5.7416 |
| STR serialNumber | 1.3.6.1.4.1.13742.4.1.1.2 | DisplayString | read-only | The serial number. |
| IP ipAddress | 1.3.6.1.4.1.13742.4.1.1.3 | IpAddress | read-only | The current IP address. A value of 0.0.0.0 indicates an error or an unset option. |
| IP netmask | 1.3.6.1.4.1.13742.4.1.1.4 | IpAddress | read-only | The current Netmask. A value of 0.0.0.0 indicates an error or an unset option. |
| IP gateway | 1.3.6.1.4.1.13742.4.1.1.5 | IpAddress | read-only | The current Gateway. A value of 0.0.0.0 indicates an error or an unset option. |
| MAC mac | 1.3.6.1.4.1.13742.4.1.1.6 | MacAddress | read-only | The current MAC address. |
| I32 hardwareRev | 1.3.6.1.4.1.13742.4.1.1.7 | Integer32 | read-only | The hardware revision number. |
| STR userName | 1.3.6.1.4.1.13742.4.1.1.10 | DisplayString | accessible-for-notify | The login of a user. |
| STR objectName | 1.3.6.1.4.1.13742.4.1.1.12 | DisplayString | accessible-for-notify | The model type of the device |
| STR objectInstance | 1.3.6.1.4.1.13742.4.1.1.13 | DisplayString | accessible-for-notify | The device name. |
| STR targetUser | 1.3.6.1.4.1.13742.4.1.1.14 | DisplayString | accessible-for-notify | The user record being operated on |
| STR groupName | 1.3.6.1.4.1.13742.4.1.1.15 | DisplayString | accessible-for-notify | The group record being operated on |
| STR imageVersion | 1.3.6.1.4.1.13742.4.1.1.18 | DisplayString | accessible-for-notify | The version of the Upgrade image |
| STR sensorDescr | 1.3.6.1.4.1.13742.4.1.1.19 | DisplayString | accessible-for-notify | Sensor description indicating which sensor experienced a threshold event. When applicable, the description will indicate the sensor number. |
| STR thresholdDescr | 1.3.6.1.4.1.13742.4.1.1.20 | DisplayString | accessible-for-notify | Threshold description indicating which configured threshold has been triggered (or cleared). |
| STR thresholdSeverity | 1.3.6.1.4.1.13742.4.1.1.21 | DisplayString | accessible-for-notify | String (Warning, Critical, etc...) indicating the severity of the threshold which has been triggered (or cleared). |
| STR thresholdEventType | 1.3.6.1.4.1.13742.4.1.1.22 | DisplayString | accessible-for-notify | String (triggered, cleared) indicating if the threshold event indicates that a configured threshold has been triggered or cleared. |
| STR status | 1.3.6.1.4.1.13742.4.1.1.23 | DisplayString | accessible-for-notify | The success status of an operation |
| IP slaveIpAddress | 1.3.6.1.4.1.13742.4.1.1.24 | IpAddress | read-only | In an outlet grouping configuration, this is the IP address of slave PDU. A value of 0.0.0.0 indicates an error or an unset option. |
| MIL inputCurrentRating | 1.3.6.1.4.1.13742.4.1.1.25 | MilliAmps | read-only | The input current Rating |
| STR ratedVoltage | 1.3.6.1.4.1.13742.4.1.1.26 | DisplayString | read-only | PDU Rated Voltage |
| STR ratedPower | 1.3.6.1.4.1.13742.4.1.1.27 | DisplayString | read-only | PDU Rated Power |
| STR outletSwitching | 1.3.6.1.4.1.13742.4.1.1.28 | DisplayString | read-write | Outlet switching: enabled/disabled; for non-switched PDUs, this value can be read, but cannot be written |
| STR dataLogging | 1.3.6.1.4.1.13742.4.1.1.29 | DisplayString | read-write | Data Retrieval: enabled/disabled |
| I32 dataLoggingInterval | 1.3.6.1.4.1.13742.4.1.1.30 | Integer32 | read-write | Data Logging periodicity in seconds. This is the periodicity of the data in the buffer. This value must be a multiple of 3 between 3 and 600. For example, 60 is valid, but 64 is not valid This is being deprecated in favor of measurementsPerLogEntry. The mapping is as follows. dataLoggingInterval measurementsPerLogEntry 3n n Example: dataLoggingInterval is 60, so every 60 seconds (or 20th sample) data will be placed in the data log measurementsPerLogEntry is 20, so the data log sill store the minimum, average and maximum of every 20 samples |
| I32 dataCollectionInterval | 1.3.6.1.4.1.13742.4.1.1.31 | Integer32 | read-only | Data Collection periodicity. This is the periodicity of the data collected by the PX. This value is fixed at 3 seconds. |
| STR outletEnergySupport | 1.3.6.1.4.1.13742.4.1.1.32 | DisplayString | read-only | Outlet Energy Support: Yes/No If the value is No, then outletWattHours and dataLogOutletWattHours will be zero |
| STR currentUnbalanceSupport | 1.3.6.1.4.1.13742.4.1.1.33 | DisplayString | read-write | current Unbalance calculations Supported: Yes/No If the value is No, then currentUnbalance will be zero Default is No |
| STR externalSensorsZCoordinateUnits | 1.3.6.1.4.1.13742.4.1.1.34 | DisplayString | read-write | External Sensor Z Coordinate units: Freeform or Rack Units (U) Default is U |
| STR inlineMeter | 1.3.6.1.4.1.13742.4.1.1.35 | DisplayString | read-only | Is this unit an inline meter? Yes/No If Yes, then the folowing pairings hold: Inlet 1 Outlet 1 Inlet 2 Outlet 2 Inlet 3 Outlet 3 Inlet 4 Outlet 4 Use the inletTable to obtain inlet data Use the inletPoleTable to obtain the line data for an inlet. |
| STA oldSensorState | 1.3.6.1.4.1.13742.4.1.1.36 | StateOfSensorEnumeration | accessible-for-notify | The old sensor state used in Sensor State Transition traps. |
| I32 externalSensorNumber | 1.3.6.1.4.1.13742.4.1.1.37 | Integer32 | accessible-for-notify | A unique value for each sensor. Its value ranges between 1 and the value of externalSensorCount. |
| STR sensorIdentificationString | 1.3.6.1.4.1.13742.4.1.1.38 | DisplayString | accessible-for-notify | String that uniquely identifies the external sensor. Format is: SensorType,ChannelNumber,SensorSubtype,SerialNumber Example external temperature sensor: Temperature,,,AEI8160083 Example external smoke detection sensor: onOff,2,contact,AEJ8160085 Example outlet Current: rmsCurrent,,, |
| BIT lastUpgradeStatus | 1.3.6.1.4.1.13742.4.1.1.39 | Bits | read-only | A bit string which indicates which the status of the last upgrade. A value of 1 for a bit position indicates that the corresponding upgrade failed. If all bits are zero, then the upgrade succeeded; otherwise check lastUpgradeErrorDescription for further information. |
| DAT lastUpgradeTimestamp | 1.3.6.1.4.1.13742.4.1.1.40 | DateAndTime | read-only | The time when the last upgrade completed |
| STR lastUpgradeErrorDescription | 1.3.6.1.4.1.13742.4.1.1.41 | DisplayString | read-only | String that describes the upgrade errror. This is an empty string if the upgrade succeeded. Format is Failed PSOCs: 1[O:1,2,3-7];3[O:6-9,10-12] This indicates that upgrade of psocs 1 and 3 failed and psoc1 affects outlets 1,2, 3-7 and psoc2 affects outlets 6-9,10-12 |
| POW powerCIMStatus | 1.3.6.1.4.1.13742.4.1.1.42 | PowerCIMStatusEnumeration | read-write | The status of the Power CIM: on or off |
| I32 measurementsPerLogEntry | 1.3.6.1.4.1.13742.4.1.1.43 | Integer32 | read-write | The number of measurements used for each entry in the log. 1<= Value <= 200 Default is 20 This is related to dataLoggingInterval as shown below dataLoggingInterval measurementsPerLogEntry 3n n Example: dataLoggingInterval is 60, so every 60 seconds (or 20th sample) data will be placed in the data log measurementsPerLogEntry is 20, so the data log sill store the minimum, average and maximum of every 20 samples |
| I32 psocNumber | 1.3.6.1.4.1.13742.4.1.1.44 | Integer32 | accessible-for-notify | The psoc (Outlet Controller) number |
| I32 altitude | 1.3.6.1.4.1.13742.4.1.1.45 | Integer32 | read-write | The altitude (height above sea level) of the PDU in meters. 0 <= Value <= 3000; default value is 0 meters |
| STR configureAlerts | 1.3.6.1.4.1.13742.4.1.1.46 | DisplayString | read-write | This is an operation. It has write-only semantics. GET operation will return the empty string. For SET operations, it configures alerts The format is a comma separated list of the following parameters. sensorClass, eventType, eventDirection, policyName For sensorclass: use the SensorClass eumeration For eventType: use the EventType enumeration For eventDirection: use the EventDirection enumeration For Policy Name: use the name of the policy; the Policy Name is case sensitive Note: setting this variable will overwrite the existing policy Example: if the External Temperature upper non-critical threshold is either asserted and deasserted, then execute the policy named multiple destinations the string would be 0,1,2,multiple destinations |
| ENA fipsMode | 1.3.6.1.4.1.13742.4.1.1.47 | EnabledDisabledEnumeration | read-write | The fips mode: either enabled or disabled. The mode can be set (changed) only if both of the following conditions hold a) the user is admin b) snmpv3 is being used. Changing this mode will result in a reboot of the PX When the PX is in FIPS mode, the follwing conditions hold. a) FIPS approved algorithms must be used b) snmp v1 & v2c are not supported b) snmp v3 must be used with AES and SHA c) https must be used; http is not supported d) Radius authentication is not supported e) Ldaps must be used; ldap is not supported f) ipmi v2.0 must be used |
| ENA synchronizeWithNTPServer | 1.3.6.1.4.1.13742.4.1.1.48 | EnabledDisabledEnumeration | read-write | Will time be obtained using NTP? Deafault is disabled, i.e. time will not be obtained from NTP servers. |
| ENA useDHCPProvidedNTPServer | 1.3.6.1.4.1.13742.4.1.1.49 | EnabledDisabledEnumeration | read-write | Will the NTP server addresses be provided by DHCP/BOOTP? This is used only if synchronizeWithNTPServer is enabled Default is enabled, i.e. DHCP provided NTP servers will be used |
| IPt primaryNTPServerAddressType | 1.3.6.1.4.1.13742.4.1.1.50 | InetAddressType | read-write | Represents the type of the corresponding instance of primaryNTPServerAddress object. |
| IP primaryNTPServerAddress | 1.3.6.1.4.1.13742.4.1.1.51 | InetAddress | read-write | The address of the primary ntp server. |
| IPt secondaryNTPServerAddressType | 1.3.6.1.4.1.13742.4.1.1.52 | InetAddressType | read-write | Represents the type of the corresponding instance of secondaryNTPServerAddress object. Default is ipv4 |
| IP secondaryNTPServerAddress | 1.3.6.1.4.1.13742.4.1.1.53 | InetAddress | read-write | The address of the secondary ntp server. |
| ENA daylightSavingsTime | 1.3.6.1.4.1.13742.4.1.1.55 | EnabledDisabledEnumeration | read-write | Is daylight savings time enabled? Default is disabled |
| STR thresholdValue | 1.3.6.1.4.1.13742.4.1.1.56 | DisplayString | accessible-for-notify | The value of the threshold that has been triggered (or cleared). It is used in the thresholdAlarm trap for external numeric sensors only. |
| STR sensorValue | 1.3.6.1.4.1.13742.4.1.1.57 | DisplayString | accessible-for-notify | The sensor reading that triggered (or cleared) the threshold. It is used in the thresholdAlarm trap for external numeric sensors only. |
| ENA ipmiOverLAN | 1.3.6.1.4.1.13742.4.1.1.58 | EnabledDisabledEnumeration | read-write | IPMI over LAN Mode: either enabled or disabled. It is strongly recommended that SNMPv3 be used to change the mode; SNMPv2c may also be used, but is not recommended. If SNMPv3 is used, then the change can be made only by users belonging to the Admin group. Changing the mode will result in a reboot of the PX. |
| outlets | 1.3.6.1.4.1.13742.4.1.2 | |||
| I32 outletCount | 1.3.6.1.4.1.13742.4.1.2.1 | Integer32 | read-only | The number of outlets (regardless of their current state) present on this pdu. |
| outletTable | 1.3.6.1.4.1.13742.4.1.2.2 | not-accessible | A list of outlet entries. The number of entries is given by the value of outletCount. | |
| outletEntry | 1.3.6.1.4.1.13742.4.1.2.2.1 | not-accessible | An outlet entry containing objects at the for a particular outlet. | |
| I32 outletIndex | 1.3.6.1.4.1.13742.4.1.2.2.1.1 | Integer32 | not-accessible | A unique value for each outlet. Its value ranges between 1 and the value of outletCount. |
| STR outletLabel | 1.3.6.1.4.1.13742.4.1.2.2.1.2 | DisplayString | read-write | A textual string containing information about the outlet. |
| INT outletOperationalState | 1.3.6.1.4.1.13742.4.1.2.2.1.3 | INTEGER | read-write | A value for each outlet which describes the operational state of the outlet. It is also used to set the operational state of the outlet |
| MIL outletCurrent | 1.3.6.1.4.1.13742.4.1.2.2.1.4 | MilliAmps | read-only | A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp) |
| MIL outletMaxCurrent | 1.3.6.1.4.1.13742.4.1.2.2.1.5 | MilliAmps | read-only | A unique value for the max. current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp) |
| MIL outletVoltage | 1.3.6.1.4.1.13742.4.1.2.2.1.6 | MilliVolts | read-only | A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt) |
| WAT outletActivePower | 1.3.6.1.4.1.13742.4.1.2.2.1.7 | Watts | read-only | A unique value for the active power sensor attached to the outlet. This value is reported in Watts. |
| VOL outletApparentPower | 1.3.6.1.4.1.13742.4.1.2.2.1.8 | VoltAmps | read-only | A unique value for the apparent power sensor attached to the outlet. This value is reported in Volt-Amps |
| POW outletPowerFactor | 1.3.6.1.4.1.13742.4.1.2.2.1.9 | PowerFactorPercentage | read-only | A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%. |
| MIL outletCurrentUpperWarning | 1.3.6.1.4.1.13742.4.1.2.2.1.20 | MilliAmps | read-write | The value of the upper warning (non-critical) current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp) |
| MIL outletCurrentUpperCritical | 1.3.6.1.4.1.13742.4.1.2.2.1.21 | MilliAmps | read-write | The value of the upper critical current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp) |
| MIL outletCurrentLowerWarning | 1.3.6.1.4.1.13742.4.1.2.2.1.22 | MilliAmps | read-write | The value of the lower warning (non-critical) current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp) |
| MIL outletCurrentLowerCritical | 1.3.6.1.4.1.13742.4.1.2.2.1.23 | MilliAmps | read-write | The value of the lower critical current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp) |
| U32 outletCurrentHysteresis | 1.3.6.1.4.1.13742.4.1.2.2.1.24 | Unsigned32 | read-write | The hysteresis used for deassertions. This value is reported in milliamps (1/1000th of an amp) |
| MIL outletCurrentRating | 1.3.6.1.4.1.13742.4.1.2.2.1.30 | MilliAmps | read-only | The current rating of the outlet. This value is reported in milliamps (1/1000th of an amp) |
| WAT outletWattHours | 1.3.6.1.4.1.13742.4.1.2.2.1.31 | WattHours | read-only | The value of the cumulative active energy for this outlet. This value is reported in WattHours |
| unit | 1.3.6.1.4.1.13742.4.1.3 | |||
| unitReadings | 1.3.6.1.4.1.13742.4.1.3.1 | |||
| MIL unitCurrent | 1.3.6.1.4.1.13742.4.1.3.1.1 | MilliAmps | read-only | The value for the unit's current sensor in millamps.This object is deprecated in favour of lineCurrent corresponding to lineCurrentLabel = L1 |
| MIL unitVoltage | 1.3.6.1.4.1.13742.4.1.3.1.2 | MilliVolts | read-only | The value for the unit's voltage sensor in millivolts.This object is deprecated in favour of lineVoltage corresponding to lineVoltageLabel = L1 |
| WAT unitActivePower | 1.3.6.1.4.1.13742.4.1.3.1.3 | Watts | read-only | The value for the unit's active power in watts.This object is deprecated in favour of inletTable.inletActivePower |
| VOL unitApparentPower | 1.3.6.1.4.1.13742.4.1.3.1.4 | VoltAmps | read-only | The value for the unit's apparent power in volt-amps. This object is deprecated in favour of inletTable.inletApparentPower |
| TEN unitCpuTemp | 1.3.6.1.4.1.13742.4.1.3.1.5 | TenthDegreesCelsius | read-only | The value for the unit's CPU temperature sensor in tenth degrees celsius. |
| MIL unitVoltageLowerWarning | 1.3.6.1.4.1.13742.4.1.3.1.60 | MilliVolts | read-write | The value of the lower warning (non-critical) unit level voltage threshold.This object is deprecated in favour of unitOrLineVoltageLowerWarning |
| MIL unitVoltageLowerCritical | 1.3.6.1.4.1.13742.4.1.3.1.61 | MilliVolts | read-write | The value of the lower critical unit level voltage threshold.This object is deprecated in favour of unitOrLineVoltageLowerCritical |
| MIL unitVoltageUpperWarning | 1.3.6.1.4.1.13742.4.1.3.1.62 | MilliVolts | read-write | The value of the upper warning (non-critical) unit level voltage threshold.This object is deprecated in favour of unitOrLineVoltageUpperWarning |
| MIL unitVoltageUpperCritical | 1.3.6.1.4.1.13742.4.1.3.1.63 | MilliVolts | read-write | The value of the upper critical unit level voltage threshold.This object is deprecated in favour of unitOrLineVoltageUpperCritical |
| MIL unitCurrentUpperWarning | 1.3.6.1.4.1.13742.4.1.3.1.70 | MilliAmps | read-write | The value of the upper warning (non-critical) unit level current threshold.This object is deprecated in favour of unitOrLineCurrentUpperWarning |
| MIL unitCurrentUpperCritical | 1.3.6.1.4.1.13742.4.1.3.1.71 | MilliAmps | read-only | The value of the upper critical unit level current threshold. NOTE: This particular threshold is NOT settable. This object is deprecated in favour of unitOrLineCurrentUpperCritica |
| DEG unitTempLowerWarning | 1.3.6.1.4.1.13742.4.1.3.1.80 | DegreesCelsius | read-write | The value of the lower warning (non-critical) unit level temperature threshold. |
| DEG unitTempLowerCritical | 1.3.6.1.4.1.13742.4.1.3.1.81 | DegreesCelsius | read-write | The value of the lower critical unit level temperature threshold. |
| DEG unitTempUpperWarning | 1.3.6.1.4.1.13742.4.1.3.1.82 | DegreesCelsius | read-write | The value of the upper warning (non-critical) unit level temperature threshold. |
| DEG unitTempUpperCritical | 1.3.6.1.4.1.13742.4.1.3.1.83 | DegreesCelsius | read-write | The value of the upper critical unit level temperature threshold. |
| STR currentUnbalance | 1.3.6.1.4.1.13742.4.1.3.1.84 | DisplayString | read-only | A string displaying the current unbalance in percent. It will have the value NA if the PX is not a 3-phase unit (inletPoleCount = 1),or the feature is disabled (currentUnbalanceSupport = 'No'), or the average of the line currents is zero (inletPoleCurrent = 0 for 1 <= inlePoleIndex <= 3) |
| PER currentUnbalanceUpperWarning | 1.3.6.1.4.1.13742.4.1.3.1.85 | Percentage | read-write | The value of the upper warning (non-critical) current unbalance threshold. |
| PER currentUnbalanceUpperCritical | 1.3.6.1.4.1.13742.4.1.3.1.86 | Percentage | read-write | The value of the upper critical current Unbalance threshold. |
| MIL unitOrLineVoltageLowerWarning | 1.3.6.1.4.1.13742.4.1.3.1.90 | MilliVolts | read-write | The value of the lower warning (non-critical) unit level voltage threshold. |
| MIL unitOrLineVoltageLowerCritical | 1.3.6.1.4.1.13742.4.1.3.1.91 | MilliVolts | read-write | The value of the lower critical unit level voltage threshold. |
| MIL unitOrLineVoltageUpperWarning | 1.3.6.1.4.1.13742.4.1.3.1.92 | MilliVolts | read-write | The value of the upper warning (non-critical) unit level voltage |
| MIL unitOrLineVoltageUpperCritical | 1.3.6.1.4.1.13742.4.1.3.1.93 | MilliVolts | read-write | The value of the upper critical unit level voltage threshold. |
| MIL unitOrLineCurrentUpperWarning | 1.3.6.1.4.1.13742.4.1.3.1.94 | MilliAmps | read-write | The value of the upper warning (non-critical) unit level current threshold |
| MIL unitOrLineCurrentUpperCritical | 1.3.6.1.4.1.13742.4.1.3.1.95 | MilliAmps | read-write | The value of the upper critical unit level current threshold. |
| MIL neutralCurrentUpperWarning | 1.3.6.1.4.1.13742.4.1.3.1.96 | MilliAmps | read-write | This object has an invalid value if inletPoleCount is not equal to 4. If inletPoleCount = 4, then it is the value of the upper warning (non-critical) threshold for the neutral current |
| MIL neutralCurrentUpperCritical | 1.3.6.1.4.1.13742.4.1.3.1.97 | MilliAmps | read-write | This object has an invalid value if inletPoleCount is not equal to 4. If inletPoleCount = 4, then it is the value of the upper critical threshold for the neutral current. |
| U32 unitOrLineCurrentHysteresis | 1.3.6.1.4.1.13742.4.1.3.1.98 | Unsigned32 | read-write | The hysteresis used for deassertions. This value is reported in milliamps (1/1000th of an amp) |
| U32 unitOrLineVoltageHysteresis | 1.3.6.1.4.1.13742.4.1.3.1.99 | Unsigned32 | read-write | The hysteresis used for deassertions. This value is reported in millivolts (1/1000th of a volt) |
| U32 unitTempHysteresis | 1.3.6.1.4.1.13742.4.1.3.1.100 | Unsigned32 | read-write | The hysteresis used for deassertions |
| U32 currentUnbalanceHysteresis | 1.3.6.1.4.1.13742.4.1.3.1.101 | Unsigned32 | read-write | The hysteresis used for deassertions |
| lineCurrents | 1.3.6.1.4.1.13742.4.1.4 | |||
| I32 lineCurrentCount | 1.3.6.1.4.1.13742.4.1.4.1 | Integer32 | read-only | The number of line currents (1 for single phase, 3 for 3 phase Delta-wired, 4 for 3 phase WYE wired).This object is deprecated in favour of inletPoleTable |
| lineCurrentTable | 1.3.6.1.4.1.13742.4.1.4.2 | not-accessible | A list of line input entries. The number of entries is given by the value of lineInputCount. This object is deprecated in favour of inletPoleTable | |
| lineCurrentEntry | 1.3.6.1.4.1.13742.4.1.4.2.1 | not-accessible | An entry containing values and threshold settings for a particular line input.This object is deprecated in favour of inletPoleTable | |
| I32 lineCurrentIndex | 1.3.6.1.4.1.13742.4.1.4.2.1.1 | Integer32 | not-accessible | A unique value for each line input. Its value ranges between 1 and lineInputCount. This object is deprecated in favour of inletPoleTable |
| STR lineCurrentLabel | 1.3.6.1.4.1.13742.4.1.4.2.1.2 | DisplayString | read-only | A string identifying the Line For Single Phase: L1 For 3phase Delta wired outlets: L1, L2, L3 For 3phase WYE Wired Outlets: L1, L2, L3, N This object is deprecated in favour of inletPoleTable |
| MIL lineCurrent | 1.3.6.1.4.1.13742.4.1.4.2.1.3 | MilliAmps | read-only | The value of the current reported in MilliAmps. This object is deprecated in favour of inletPoleTable |
| circuitBreaker | 1.3.6.1.4.1.13742.4.1.5 | |||
| I32 circuitBreakerCount | 1.3.6.1.4.1.13742.4.1.5.1 | Integer32 | read-only | The number of circuit breakers. |
| circuitBreakerTable | 1.3.6.1.4.1.13742.4.1.5.2 | not-accessible | A list of line input entries. The number of entries is given by the value of lineInputCount. | |
| circuitBreakerEntry | 1.3.6.1.4.1.13742.4.1.5.2.1 | not-accessible | An entry containing values and threshold settings for a particular line input. | |
| I32 circuitBreakerIndex | 1.3.6.1.4.1.13742.4.1.5.2.1.1 | Integer32 | not-accessible | A unique value for each circuit breaker. Its value ranges between 1 and circuitBreakerCount. |
| STR circuitBreakerLabel | 1.3.6.1.4.1.13742.4.1.5.2.1.2 | DisplayString | read-only | A string identifying the circuit breaker |
| INT circuitBreakerState | 1.3.6.1.4.1.13742.4.1.5.2.1.3 | INTEGER | read-only | The value for the circuit breaker state . |
| MIL circuitBreakerCurrentRating | 1.3.6.1.4.1.13742.4.1.5.2.1.4 | MilliAmps | read-only | The value of the circuit breaker current rating in MilliAmps. |
| MIL circuitBreakerCurrent | 1.3.6.1.4.1.13742.4.1.5.2.1.5 | MilliAmps | read-only | The value of the current reported in MilliAmps. |
| MIL circuitBreakerCurrentUpperWarning | 1.3.6.1.4.1.13742.4.1.5.2.1.7 | MilliAmps | read-write | The value of the upper warning (non-critical) threshold. |
| MIL circuitBreakerCurrentUpperCritical | 1.3.6.1.4.1.13742.4.1.5.2.1.9 | MilliAmps | read-write | The value of the upper critical threshold. |
| U32 circuitBreakerCurrentHysteresis | 1.3.6.1.4.1.13742.4.1.5.2.1.10 | Unsigned32 | read-write | The hysteresis used for deassertions reported in milliamps (1/1000th of an amp) |
| lineVoltages | 1.3.6.1.4.1.13742.4.1.6 | |||
| I32 lineVoltageCount | 1.3.6.1.4.1.13742.4.1.6.1 | Integer32 | read-only | The number of line voltages (1 for single phase, 3 for 3 phase. This object is deprecated in favour of inletPoleTable |
| lineVoltageTable | 1.3.6.1.4.1.13742.4.1.6.2 | not-accessible | A list of line input entries. The number of entries is given by the value of lineInputCount. This object is deprecated in favour of linletPoleTable | |
| lineVoltageEntry | 1.3.6.1.4.1.13742.4.1.6.2.1 | not-accessible | An entry containing values and threshold settings for a particular line input. This object is deprecated in favour of inletPoleTable | |
| I32 lineVoltageIndex | 1.3.6.1.4.1.13742.4.1.6.2.1.1 | Integer32 | not-accessible | A unique value for each line input. Its value ranges between 1 and lineInputCount. This object is deprecated in favour of inletPoleTable |
| STR lineVoltageLabel | 1.3.6.1.4.1.13742.4.1.6.2.1.2 | DisplayString | read-only | A string identifying the Line For Single Phase: L1 For 3phase Delta-wired: L1-L2, L2-L3, L3-L1 For 3phase Wye-wired: L1-N, L2-N, L3-N This object is deprecated in favour of inletPoleTable |
| MIL lineVoltage | 1.3.6.1.4.1.13742.4.1.6.2.1.3 | MilliVolts | read-only | The value of the voltage reported in MilliVolts. This object is deprecated in favour of inletPoleTable |
| dataLog | 1.3.6.1.4.1.13742.4.1.7 | |||
| I32 dataLogCount | 1.3.6.1.4.1.13742.4.1.7.1 | Integer32 | read-only | The number of entries in the dataLog table which is a circular buffer. |
| I32 dataLogLatestIndex | 1.3.6.1.4.1.13742.4.1.7.2 | Integer32 | read-only | The index of the latest (most recent) entry in dataLogTable . |
| dataLogTable | 1.3.6.1.4.1.13742.4.1.7.3 | not-accessible | A list of data log entries. The number of entries is given by the value of dataLogCount. | |
| dataLogEntry | 1.3.6.1.4.1.13742.4.1.7.3.1 | not-accessible | An entry in the dataLog buffer containing the unit data collected at the instant specified by dataLogTimeStamp | |
| I32 dataLogIndex | 1.3.6.1.4.1.13742.4.1.7.3.1.1 | Integer32 | not-accessible | A unique value for each data sample. Its value ranges between 1 and dataLogCount . |
| U32 dataLogTimeStamp | 1.3.6.1.4.1.13742.4.1.7.3.1.2 | Unsigned32 | read-only | The time when the data was collected. It is measured in seconds relative to January 1, 1970 (midnight UTC/GMT), i.e a value of 0 indicates January 1, 1970 (midnight UTC/GMT) |
| WAT dataLogActivePower | 1.3.6.1.4.1.13742.4.1.7.3.1.3 | Watts | read-only | The value for the pdu's active power sensor in watts. This has been deprecated in favor of dataLogAvgActivePower, dataLogMaxActivePower,dataLogMinActivePower |
| VOL dataLogApparentPower | 1.3.6.1.4.1.13742.4.1.7.3.1.4 | VoltAmps | read-only | The value for the pdu's apparent power sensor in volt-amps. This has been deprecated in favor of dataLogAvgApparentPower, dataLogMaxApparentPower,dataLogMinApparentPower |
| WAT dataLogAvgActivePower | 1.3.6.1.4.1.13742.4.1.7.3.1.5 | Watts | read-only | The average active power for this measurement period |
| WAT dataLogMaxActivePower | 1.3.6.1.4.1.13742.4.1.7.3.1.6 | Watts | read-only | The maximum active power for this measurement period |
| WAT dataLogMinActivePower | 1.3.6.1.4.1.13742.4.1.7.3.1.7 | Watts | read-only | The minimum active power for this measurement period |
| VOL dataLogAvgApparentPower | 1.3.6.1.4.1.13742.4.1.7.3.1.8 | VoltAmps | read-only | The average apparent power for this measurement period |
| VOL dataLogMaxApparentPower | 1.3.6.1.4.1.13742.4.1.7.3.1.9 | VoltAmps | read-only | The maximum apparent power for this measurement period |
| VOL dataLogMinApparentPower | 1.3.6.1.4.1.13742.4.1.7.3.1.10 | VoltAmps | read-only | The minimum apparent power for this measurement period |
| dataLogOutlet | 1.3.6.1.4.1.13742.4.1.10 | |||
| dataLogOutletTable | 1.3.6.1.4.1.13742.4.1.10.1 | not-accessible | A list of outlet entries. The number of entries is given by the value of outletCount. | |
| dataLogOutletEntry | 1.3.6.1.4.1.13742.4.1.10.1.1 | not-accessible | An entry in the data log containing outlet level data for a particular outlet. | |
| I32 dataLogOutletIndex | 1.3.6.1.4.1.13742.4.1.10.1.1.1 | Integer32 | not-accessible | A unique value for each outlet. Its value ranges between 1 and the value of outletCount. |
| MIL dataLogOutletCurrent | 1.3.6.1.4.1.13742.4.1.10.1.1.2 | MilliAmps | read-only | A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp) This has been deprecated in favor of dataLogAvgOutletCurrent , dataLogMaxOutletCurrent ,dataLogMinOutletCurrent |
| MIL dataLogOutletVoltage | 1.3.6.1.4.1.13742.4.1.10.1.1.3 | MilliVolts | read-only | A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt) This has been deprecated in favor of dataLogAvgOutletVoltage , dataLogMaxOutletVoltage ,dataLogMinOutletVoltage |
| POW dataLogOutletPowerFactor | 1.3.6.1.4.1.13742.4.1.10.1.1.4 | PowerFactorPercentage | read-only | A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%. This has been deprecated in favor of dataLogAvgOutletPowerFactor, dataLogMaxOutletPowerFactor,dataLogMinOutletPowerFactor |
| U32 dataLogOutletOnTime | 1.3.6.1.4.1.13742.4.1.10.1.1.5 | Unsigned32 | read-only | The amount of time since this outlet was last switched on. This value is reported in seconds. |
| WAT dataLogOutletWattHours | 1.3.6.1.4.1.13742.4.1.10.1.1.6 | WattHours | read-only | The cumulative Active Energy for this outlet. This value is reported in WattHours This has been deprecated in favor of dataLogAvgOutletWattHours , dataLogMaxOutletWattHours ,dataLogMinOutletWattHours |
| MIL dataLogAvgOutletCurrent | 1.3.6.1.4.1.13742.4.1.10.1.1.7 | MilliAmps | read-only | The Average value for the measurement period: A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp) |
| MIL dataLogMaxOutletCurrent | 1.3.6.1.4.1.13742.4.1.10.1.1.8 | MilliAmps | read-only | The Maximum value for the measurement period: A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp) |
| MIL dataLogMinOutletCurrent | 1.3.6.1.4.1.13742.4.1.10.1.1.9 | MilliAmps | read-only | The Minimum value for the measurement period: A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp) |
| MIL dataLogAvgOutletVoltage | 1.3.6.1.4.1.13742.4.1.10.1.1.10 | MilliVolts | read-only | The Average value for the measurement period: A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt) |
| MIL dataLogMaxOutletVoltage | 1.3.6.1.4.1.13742.4.1.10.1.1.11 | MilliVolts | read-only | The Maximum value for the measurement period: A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt) |
| MIL dataLogMinOutletVoltage | 1.3.6.1.4.1.13742.4.1.10.1.1.12 | MilliVolts | read-only | The Minimum value for the measurement period: A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt) |
| POW dataLogAvgOutletPowerFactor | 1.3.6.1.4.1.13742.4.1.10.1.1.13 | PowerFactorPercentage | read-only | The Average value for the measurement period: A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100% |
| POW dataLogMaxOutletPowerFactor | 1.3.6.1.4.1.13742.4.1.10.1.1.14 | PowerFactorPercentage | read-only | The Maximum value for the measurement period: A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100% |
| POW dataLogMinOutletPowerFactor | 1.3.6.1.4.1.13742.4.1.10.1.1.15 | PowerFactorPercentage | read-only | The Minimum value for the measurement period: A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100% |
| WAT dataLogAvgOutletWattHours | 1.3.6.1.4.1.13742.4.1.10.1.1.16 | WattHours | read-only | The Average value for the measurement period: The cumulative Active Energy for this outlet. This value is reported in WattHours |
| WAT dataLogMaxOutletWattHours | 1.3.6.1.4.1.13742.4.1.10.1.1.17 | WattHours | read-only | The Maximum value for the measurement period: The cumulative Active Energy for this outlet. This value is reported in WattHours |
| WAT dataLogMinOutletWattHours | 1.3.6.1.4.1.13742.4.1.10.1.1.18 | WattHours | read-only | The Minimum value for the measurement period: The cumulative Active Energy for this outlet. This value is reported in WattHours |
| dataLogInlet | 1.3.6.1.4.1.13742.4.1.12 | |||
| dataLogInletTable | 1.3.6.1.4.1.13742.4.1.12.2 | not-accessible | A list of inlet entries. The number of entries is given by the value of inletCount. | |
| dataLogInletEntry | 1.3.6.1.4.1.13742.4.1.12.2.1 | not-accessible | An inlet entry containing objects at the for a particular outlet. | |
| I32 dataLogInletIndex | 1.3.6.1.4.1.13742.4.1.12.2.1.1 | Integer32 | not-accessible | A unique value for each inlet. Its value ranges between 1 and the value of inletCount. |
| STR dataLogInletCurrentUnbalance | 1.3.6.1.4.1.13742.4.1.12.2.1.10 | DisplayString | read-only | A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zero This has been deprecated in favor of dataLogAvgInletCurrentUnbalance, dataLogMaxInletCurrentUnbalance, dataLogMinInletCurrentUnbalance |
| WAT dataLogInletActivePower | 1.3.6.1.4.1.13742.4.1.12.2.1.11 | Watts | read-only | The active power for the inlet This value is reported in Watts. This has been deprecated in favor of dataLogAvgInletActivePower, dataLogMaxInletActivePower, dataLogMinInletActivePower |
| VOL dataLogInletApparentPower | 1.3.6.1.4.1.13742.4.1.12.2.1.12 | VoltAmps | read-only | The apparent power for the inlet. This value is reported in Volt-Amps This has been deprecated in favor of dataLogAvgInletApparentPower, dataLogMaxInletApparentPower, dataLogMinInletApparentPower |
| WAT dataLogInletActiveEnergy | 1.3.6.1.4.1.13742.4.1.12.2.1.13 | WattHours | read-only | The value of the cumulative active energy for this inlet. This value is reported in WattHours This has been deprecated in favor of dataLogAvgInletActiveEnergy, dataLogMaxInletActiveEnergy, dataLogMinInletActiveEnergy |
| STR dataLogAvgInletCurrentUnbalance | 1.3.6.1.4.1.13742.4.1.12.2.1.14 | DisplayString | read-only | The average value of the current unbalance for this measurement period A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zero |
| STR dataLogMaxInletCurrentUnbalance | 1.3.6.1.4.1.13742.4.1.12.2.1.15 | DisplayString | read-only | The Maximum value for the measurement period: A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zero |
| STR dataLogMinInletCurrentUnbalance | 1.3.6.1.4.1.13742.4.1.12.2.1.16 | DisplayString | read-only | The Minimum value for the measurement period: A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zero |
| WAT dataLogAvgInletActivePower | 1.3.6.1.4.1.13742.4.1.12.2.1.17 | Watts | read-only | The Average value for the measurement period: The active power for the inlet This value is reported in Watts. |
| WAT dataLogMaxInletActivePower | 1.3.6.1.4.1.13742.4.1.12.2.1.18 | Watts | read-only | The Maximum value for the measurement period: The active power for the inlet This value is reported in Watts. |
| WAT dataLogMinInletActivePower | 1.3.6.1.4.1.13742.4.1.12.2.1.19 | Watts | read-only | The Minimum value for the measurement period: The active power for the inlet This value is reported in Watts. |
| VOL dataLogAvgInletApparentPower | 1.3.6.1.4.1.13742.4.1.12.2.1.20 | VoltAmps | read-only | The Average value for the measurement period: The apparent power for the inlet. This value is reported in Volt-Amps |
| VOL dataLogMaxInletApparentPower | 1.3.6.1.4.1.13742.4.1.12.2.1.21 | VoltAmps | read-only | The Maximum value for the measurement period: The apparent power for the inlet. This value is reported in Volt-Amps |
| VOL dataLogMinInletApparentPower | 1.3.6.1.4.1.13742.4.1.12.2.1.22 | VoltAmps | read-only | The Minimum value for the measurement period: The apparent power for the inlet. This value is reported in Volt-Amps |
| WAT dataLogAvgInletActiveEnergy | 1.3.6.1.4.1.13742.4.1.12.2.1.23 | WattHours | read-only | The Average value for the measurement period: The value of the cumulative active energy for this inlet. This value is reported in WattHours |
| WAT dataLogMaxInletActiveEnergy | 1.3.6.1.4.1.13742.4.1.12.2.1.24 | WattHours | read-only | The Maximum value for the measurement period: The value of the cumulative active energy for this inlet. This value is reported in WattHours |
| WAT dataLogMinInletActiveEnergy | 1.3.6.1.4.1.13742.4.1.12.2.1.25 | WattHours | read-only | The Minimum value for the measurement period: The value of the cumulative active energy for this inlet. This value is reported in WattHours |
| dataLogInletPole | 1.3.6.1.4.1.13742.4.1.13 | |||
| dataLogInletPoleTable | 1.3.6.1.4.1.13742.4.1.13.1 | not-accessible | A list of line input entries. The number of entries is given by the value of dataLoginletTable(dataLogInletIndex).inletPoleCount. | |
| dataLogInletPoleEntry | 1.3.6.1.4.1.13742.4.1.13.1.1 | not-accessible | An entry in the data log containing input line values for a particular input line. | |
| I32 dataLogInletPoleIndex | 1.3.6.1.4.1.13742.4.1.13.1.1.1 | Integer32 | not-accessible | A unique value for each line input. Its value ranges between 1 and lineCurrentCount. |
| MIL dataLogInletPoleCurrent | 1.3.6.1.4.1.13742.4.1.13.1.1.2 | MilliAmps | read-only | The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, N This has been deprecated in favor of dataLogAvgInletPoleCurrent, dataLogMaxInletPoleCurrent, dataLogMinInletPoleCurrent |
| MIL dataLogInletPoleVoltage | 1.3.6.1.4.1.13742.4.1.13.1.1.3 | MilliVolts | read-only | The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-N This has been deprecated in favor of dataLogAvgInletPoleVoltage, dataLogMaxInletPoleVoltage, dataLogMinInletPoleVoltage |
| MIL dataLogAvgInletPoleCurrent | 1.3.6.1.4.1.13742.4.1.13.1.1.4 | MilliAmps | read-only | The Average value for the measurement period: The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, N |
| MIL dataLogMaxInletPoleCurrent | 1.3.6.1.4.1.13742.4.1.13.1.1.5 | MilliAmps | read-only | The Maximum value for the measurement period: The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, N |
| MIL dataLogMinInletPoleCurrent | 1.3.6.1.4.1.13742.4.1.13.1.1.6 | MilliAmps | read-only | The Minimum value for the measurement period: The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, N |
| MIL dataLogAvgInletPoleVoltage | 1.3.6.1.4.1.13742.4.1.13.1.1.7 | MilliVolts | read-only | The Average value for the measurement period: The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-N |
| MIL dataLogMaxInletPoleVoltage | 1.3.6.1.4.1.13742.4.1.13.1.1.8 | MilliVolts | read-only | The Maximum value for the measurement period: The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-N |
| MIL dataLogMinInletPoleVoltage | 1.3.6.1.4.1.13742.4.1.13.1.1.9 | MilliVolts | read-only | The Minimum value for the measurement period: The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-N |
| WAT dataLogAvgInletPoleActivePower | 1.3.6.1.4.1.13742.4.1.13.1.1.10 | Watts | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Average value of the active power for the measurement period. The value is reported in Watts. |
| WAT dataLogMaxInletPoleActivePower | 1.3.6.1.4.1.13742.4.1.13.1.1.11 | Watts | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Maximum value of the active power for the measurement period. The value is reported in Watts. |
| WAT dataLogMinInletPoleActivePower | 1.3.6.1.4.1.13742.4.1.13.1.1.12 | Watts | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Minimum value of the active power for the measurement period. The value is reported in Watts. |
| VOL dataLogAvgInletPoleApparentPower | 1.3.6.1.4.1.13742.4.1.13.1.1.13 | VoltAmps | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Average value of the apparent power for the measurement period. The value is reported in Volt-Amps |
| VOL dataLogMaxInletPoleApparentPower | 1.3.6.1.4.1.13742.4.1.13.1.1.14 | VoltAmps | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Maximum value of the apparent power for the measurement period. The value is reported in Volt-Amps |
| VOL dataLogMinInletPoleApparentPower | 1.3.6.1.4.1.13742.4.1.13.1.1.15 | VoltAmps | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Minimum value of the apparent power for the measurement period. The value is reported in Volt-Amps |
| WAT dataLogAvgInletPoleActiveEnergy | 1.3.6.1.4.1.13742.4.1.13.1.1.16 | WattHours | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Average value of the active energy for the measurement period. The value is reported in WattHours |
| WAT dataLogMaxInletPoleActiveEnergy | 1.3.6.1.4.1.13742.4.1.13.1.1.17 | WattHours | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Maximum value of the active energy for the measurement period. The value is reported in WattHours |
| WAT dataLogMinInletPoleActiveEnergy | 1.3.6.1.4.1.13742.4.1.13.1.1.18 | WattHours | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Minimum value of the active energy for the measurement period. The value is reported in WattHours |
| dataLogInputLine | 1.3.6.1.4.1.13742.4.1.14 | |||
| dataLogInputLineTable | 1.3.6.1.4.1.13742.4.1.14.1 | not-accessible | A list of line input entries. The number of entries is given by the value of lineCurrentCount. This object is deprecated in favour of dataLogInletLineTable | |
| dataLogInputLineEntry | 1.3.6.1.4.1.13742.4.1.14.1.1 | not-accessible | An entry in the data log containing input line values for a particular input line. This object is deprecated in favour of dataLogInletLineTable | |
| I32 dataLogInputLineIndex | 1.3.6.1.4.1.13742.4.1.14.1.1.1 | Integer32 | not-accessible | A unique value for each line input. Its value ranges between 1 and inletTable(inletIndex).inletPoleCount. This object is deprecated in favour of dataLogInletLineTable |
| MIL dataLogInputLineCurrent | 1.3.6.1.4.1.13742.4.1.14.1.1.2 | MilliAmps | read-only | The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, N This object is deprecated in favour of dataLogInletLineTable |
| MIL dataLogInputLineVoltage | 1.3.6.1.4.1.13742.4.1.14.1.1.3 | MilliVolts | read-only | The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-N This object is deprecated in favour of dataLogInletLineTable |
| dataLogCircuitBreaker | 1.3.6.1.4.1.13742.4.1.15 | |||
| dataLogCircuitBreakerTable | 1.3.6.1.4.1.13742.4.1.15.1 | not-accessible | A list of circuit breaker entries. The number of entries is given by the value of circuitBreakerCount. | |
| dataLogCircuitBreakerEntry | 1.3.6.1.4.1.13742.4.1.15.1.1 | not-accessible | An entry in the data log containing circuit breaker values | |
| I32 dataLogCircuitBreakerIndex | 1.3.6.1.4.1.13742.4.1.15.1.1.1 | Integer32 | not-accessible | A unique value for each circuit breaker. Its value ranges between 1 and circuitBreakerCount. |
| MIL dataLogCircuitBreakerCurrent | 1.3.6.1.4.1.13742.4.1.15.1.1.2 | MilliAmps | read-only | The value of the current reported in MilliAmps. This has been deprecated in favor of dataLogAvgCircuitBreakerCurrent, dataLogMaxOutletCircuitBreakerCurrent, dataLogMinCircuitBreakerCurrent |
| MIL dataLogAvgCircuitBreakerCurrent | 1.3.6.1.4.1.13742.4.1.15.1.1.3 | MilliAmps | read-only | The Average value for the measurement period: The value of the current reported in MilliAmps. |
| MIL dataLogMaxCircuitBreakerCurrent | 1.3.6.1.4.1.13742.4.1.15.1.1.4 | MilliAmps | read-only | The Maximum value for the measurement period: The value of the current reported in MilliAmps. |
| MIL dataLogMinCircuitBreakerCurrent | 1.3.6.1.4.1.13742.4.1.15.1.1.5 | MilliAmps | read-only | The Minimum value for the measurement period: The value of the current reported in MilliAmps. |
| dataLogExternalSensor | 1.3.6.1.4.1.13742.4.1.16 | |||
| dataLogExternalSensorTable | 1.3.6.1.4.1.13742.4.1.16.1 | not-accessible | A list of external sensor entries. The number of entries is given by the value of externalSensorCount. | |
| dataLogExternalSensorEntry | 1.3.6.1.4.1.13742.4.1.16.1.1 | not-accessible | An entry in the data log containing external sensor values | |
| I32 dataLogExternalSensorIndex | 1.3.6.1.4.1.13742.4.1.16.1.1.1 | Integer32 | not-accessible | A unique value for each external sensor. Its value ranges between 1 and externalSensorCount. |
| STR dataLogExternalSensorChanged | 1.3.6.1.4.1.13742.4.1.16.1.1.2 | DisplayString | read-only | Indicates whether there has been a change in the sensor type/subtype/channel number for this sensorID. This can occur if sensorIDs have been reassigned as a result of a GUI operation or a SET operation on reorderexternalSensorTableEntries. Format: SerialNumber=xxxxxxxx; SensorType=dd; SensorSubType=d; ChannelNumber=d SensorSubType and ChannelNumber are present only if NewSensorType=onOff If there was no change from the previous sample, then this string is empty. Examples: Sensor changed to Temperature: SerialNumber=AEI8160083; SensorType=10; Sensor changed to onOff/SmokeDetection: SerialNumber=AEI8160083; SensorType=14; SensorSubType= 18; ChannelNumber=1 Sensor Channel Number changed: SerialNumber=AEI8160083; SensorType=14; SensorSubType= 18; ChannelNumber=2 Sensor SubType changed: SerialNumber=AEI8160083; SensorType=14; SensorSubType= 19; ChannelNumber=2 |
| STA dataLogExternalSensorState | 1.3.6.1.4.1.13742.4.1.16.1.1.3 | StateOfSensorEnumeration | read-only | The sensor state. |
| I32 dataLogAvgExternalSensorValue | 1.3.6.1.4.1.13742.4.1.16.1.1.4 | Integer32 | read-only | The Average of the sensor values Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors. This value is not valid if dataLogExternalSensorState is unavailable(-1). |
| I32 dataLogMaxExternalSensorValue | 1.3.6.1.4.1.13742.4.1.16.1.1.5 | Integer32 | read-only | The Maximum of the sensor values Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors This value is not valid if dataLogExternalSensorState is unavailable(-1). |
| I32 dataLogMinExternalSensorValue | 1.3.6.1.4.1.13742.4.1.16.1.1.6 | Integer32 | read-only | The Minimum of the sensor values. Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors This value is not valid if dataLogExternalSensorState is unavailable(-1). |
| inlets | 1.3.6.1.4.1.13742.4.1.20 | |||
| I32 inletCount | 1.3.6.1.4.1.13742.4.1.20.1 | Integer32 | read-only | The number of inlets present on this pdu. |
| inletTable | 1.3.6.1.4.1.13742.4.1.20.2 | not-accessible | A list of inlet entries. The number of entries is given by the value of inletCount. | |
| inletEntry | 1.3.6.1.4.1.13742.4.1.20.2.1 | not-accessible | An inlet entry containing objects for each inlet | |
| I32 inletIndex | 1.3.6.1.4.1.13742.4.1.20.2.1.1 | Integer32 | not-accessible | A unique value for each inlet. Its value ranges between 1 and the value of inletCount. |
| I32 inletPoleCount | 1.3.6.1.4.1.13742.4.1.20.2.1.3 | Integer32 | read-only | The number of poles for an inlet (1 for single phase, 3 for 3 phase Delta-wired, 4 for 3 phase WYE wired). |
| MIL inletCurrentRating | 1.3.6.1.4.1.13742.4.1.20.2.1.4 | MilliAmps | read-only | The input current Rating |
| MIL inletCurrent | 1.3.6.1.4.1.13742.4.1.20.2.1.7 | MilliAmps | read-only | A unique value for the current sensor attached to the inlet. This value is reported in milliamps (1/1000th of an amp). This OID does not apply to 3 phase systems; a value of 0 will be reported for same. |
| MIL inletVoltage | 1.3.6.1.4.1.13742.4.1.20.2.1.8 | MilliVolts | read-only | A unique value for the voltage sensor attached to the intlet.This value is reported in millivolts (1/1000th of a volt). This OID does not apply to 3 phase systems; a value of 0 will be reported for same. |
| WAT inletActivePower | 1.3.6.1.4.1.13742.4.1.20.2.1.9 | Watts | read-only | The active power for the inlet This value is reported in Watts. |
| VOL inletApparentPower | 1.3.6.1.4.1.13742.4.1.20.2.1.10 | VoltAmps | read-only | The apparent power for the inlet. This value is reported in Volt-Amps |
| POW inletPowerFactor | 1.3.6.1.4.1.13742.4.1.20.2.1.11 | PowerFactorPercentage | read-only | A unique value for the power factor of the inlet. The reading represents a percentage in the range of 0% to 100%. |
| WAT inletActiveEnergy | 1.3.6.1.4.1.13742.4.1.20.2.1.12 | WattHours | read-only | This object has an invalid value if outletEnergySupport = 'No'; In all other cases, it is the value of the cumulative active energy for this inlet. This value is reported in WattHours |
| STR inletCurrentUnbalance | 1.3.6.1.4.1.13742.4.1.20.2.1.15 | DisplayString | read-only | A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zero |
| MIL inletCurrentUpperWarning | 1.3.6.1.4.1.13742.4.1.20.2.1.20 | MilliAmps | read-write | The value of the upper warning (non-critical) current threshold for the inlet. This value is reported in milliamps (1/1000th of an amp) |
| MIL inletCurrentUpperCritical | 1.3.6.1.4.1.13742.4.1.20.2.1.21 | MilliAmps | read-write | The value of the upper critical current threshold for the inlet. This value is reported in milliamps (1/1000th of an amp) |
| MIL inletCurrentLowerWarning | 1.3.6.1.4.1.13742.4.1.20.2.1.22 | MilliAmps | read-write | The value of the lower warning (non-critical) current threshold for the inlet. This value is reported in milliamps (1/1000th of an amp). This OID is valid for inline meter PDU's. only |
| MIL inletCurrentLowerCritical | 1.3.6.1.4.1.13742.4.1.20.2.1.23 | MilliAmps | read-write | The value of the lower critical current threshold for the inlet. This value is reported in milliamps (1/1000th of an amp). This OID is valid for inline meter PDU's only. |
| MIL inletVoltageUpperWarning | 1.3.6.1.4.1.13742.4.1.20.2.1.24 | MilliVolts | read-write | The value of the upper warning (non-critical) current threshold for the inlet. This value is reported in millivolts (1/1000th of a volt) |
| MIL inletVoltageUpperCritical | 1.3.6.1.4.1.13742.4.1.20.2.1.25 | MilliVolts | read-write | The value of the upper critical current threshold for the inlet. This value is reported in millivolts (1/1000th of a volt) |
| MIL inletVoltageLowerWarning | 1.3.6.1.4.1.13742.4.1.20.2.1.26 | MilliVolts | read-write | The value of the lower warning (non-critical) current threshold for the inlet. This value is reported in millivolts (1/1000th of a volt) |
| MIL inletVoltageLowerCritical | 1.3.6.1.4.1.13742.4.1.20.2.1.27 | MilliVolts | read-write | The value of the lower critical current threshold for the inlet. This value is reported in millivolts (1/1000th of a volt) |
| PER inletCurrentUnbalanceUpperCritical | 1.3.6.1.4.1.13742.4.1.20.2.1.28 | Percentage | read-write | The value of the upper critical current Unbalance threshold. |
| PER inletCurrentUnbalanceUpperWarning | 1.3.6.1.4.1.13742.4.1.20.2.1.29 | Percentage | read-write | The value of the upper warning current Unbalance threshold. |
| U32 inletCurrentHysteresis | 1.3.6.1.4.1.13742.4.1.20.2.1.30 | Unsigned32 | read-write | The hysteresis used for deassertions. This value is reported in milliamps (1/1000th of an amp) |
| U32 inletVoltageHysteresis | 1.3.6.1.4.1.13742.4.1.20.2.1.31 | Unsigned32 | read-write | The hysteresis used for deassertions. This value is reported in millivolts (1/1000th of a volt) |
| U32 inletCurrentUnbalanceHysteresis | 1.3.6.1.4.1.13742.4.1.20.2.1.32 | Unsigned32 | read-write | The hysteresis used for deassertions. This value is reported in percent |
| inletPole | 1.3.6.1.4.1.13742.4.1.21 | |||
| inletPoleTable | 1.3.6.1.4.1.13742.4.1.21.2 | not-accessible | A list of line input entries. The number of entries is given by the value of inletTable(inletIndex).inletPoleCount. | |
| inletPoleEntry | 1.3.6.1.4.1.13742.4.1.21.2.1 | not-accessible | An entry in the data log containing input line values for a particular input line. | |
| I32 inletPoleIndex | 1.3.6.1.4.1.13742.4.1.21.2.1.1 | Integer32 | not-accessible | A unique value for each line input. Its value ranges between 1 and of inletTable(inletIndex).inletPoleCount. |
| STR inletPoleLabel | 1.3.6.1.4.1.13742.4.1.21.2.1.2 | DisplayString | read-only | A string identifying the Line For Single Phase: L1 For 3phase Delta wired outlets: L1, L2, L3 For 3phase WYE Wired Outlets: L1, L2, L3 |
| MIL inletPoleCurrent | 1.3.6.1.4.1.13742.4.1.21.2.1.3 | MilliAmps | read-only | The value of the line current reported in MilliAmps. inletPoleIndex = 1; For Single Phase, Input Line Current; For 3-phase, L1 Current inletPoleIndex = 2; For 3-phase, L2 Current inletPoleIndex = 3; For 3-phase, L3 Current |
| MIL inletPoleVoltage | 1.3.6.1.4.1.13742.4.1.21.2.1.4 | MilliVolts | read-only | The value of the line-line voltage reported in MilliVolts. inletPoleIndex = 1; Single Phase Input Line Voltage 3-phase, L1-L2 Voltage or L1-N voltage inletPoleIndex = 2; 3-phase L2-L3 Voltage or L2-N voltage inletPoleaIndex = 3; 3-phase L3-L1 Voltage or L3-N voltage |
| MIL inletPoleMaxCurrent | 1.3.6.1.4.1.13742.4.1.21.2.1.5 | MilliAmps | read-only | This object has an invalid value for a single-phase PDU. If inletPoleCount = 1, then the value is invalid; In all other cases, it is the value of the max. current sensor attached to the inlet Pole. This value is reported in milliamps (1/1000th of an amp) |
| WAT inletPoleActivePower | 1.3.6.1.4.1.13742.4.1.21.2.1.7 | Watts | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the active power for the line/pole. The value is reported in Watts. |
| VOL inletPoleApparentPower | 1.3.6.1.4.1.13742.4.1.21.2.1.8 | VoltAmps | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the apparent power for the line/pole. The value is reported in Volt-Amps |
| POW inletPolePowerFactor | 1.3.6.1.4.1.13742.4.1.21.2.1.9 | PowerFactorPercentage | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the power factor for the line/pole The reading represents a percentage in the range of 0% to 100%. |
| WAT inletPoleActiveEnergy | 1.3.6.1.4.1.13742.4.1.21.2.1.11 | WattHours | read-only | This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the cumulative active energy for the line/pole. The value is reported in WattHours |
| environmental | 1.3.6.1.4.1.13742.4.2 | |||
| I32 tempSensorCount | 1.3.6.1.4.1.13742.4.2.1 | Integer32 | read-only | The number of external temperature sensors (regardless of their current state) present on this pdu. This is deprecated in favor of externalSensors |
| tempSensorTable | 1.3.6.1.4.1.13742.4.2.2 | not-accessible | A list of temperature sensor entries. The number of entries is given by the value of tempSensorCount. This is deprecated in favor of externalSensors | |
| tempSensorEntry | 1.3.6.1.4.1.13742.4.2.2.1 | not-accessible | An entry containing sensor reading and threshold settings for a particular temperature sensor. This is deprecated in favor of externalSensors | |
| I32 tempSensorIndex | 1.3.6.1.4.1.13742.4.2.2.1.1 | Integer32 | not-accessible | A unique value for each temperature sensor. Its value ranges between 1 and tempSensorCount. This is deprecated in favor of externalSensors |
| STR tempSensorLabel | 1.3.6.1.4.1.13742.4.2.2.1.2 | DisplayString | read-write | A settable human-readable label for the external temperature sensor. One possible use for this label is to convey sensor location. This is deprecated in favor of externalSensors |
| TEN temperature | 1.3.6.1.4.1.13742.4.2.2.1.3 | TenthDegreesCelsius | read-only | The value of the external temperature sensor reported in tenth degrees celsius. This is deprecated in favor of externalSensors |
| DEG tempLowerWarning | 1.3.6.1.4.1.13742.4.2.2.1.4 | DegreesCelsius | read-write | The value of the lower warning (non-critical) threshold. This is deprecated in favor of externalSensors |
| DEG tempUpperWarning | 1.3.6.1.4.1.13742.4.2.2.1.5 | DegreesCelsius | read-write | The value of the upper warning (non-critical) threshold. This is deprecated in favor of externalSensors |
| DEG tempLowerCritical | 1.3.6.1.4.1.13742.4.2.2.1.6 | DegreesCelsius | read-write | The value of the lower critical threshold. This is deprecated in favor of externalSensors |
| DEG tempUpperCritical | 1.3.6.1.4.1.13742.4.2.2.1.7 | DegreesCelsius | read-write | The value of the upper critical threshold. This is deprecated in favor of externalSensors |
| STR tempXCoordinate | 1.3.6.1.4.1.13742.4.2.2.1.8 | DisplayString | read-write | The value of X coordinate in freeform with number of characters <= 24 This is deprecated in favor of externalSensors |
| STR tempYCoordinate | 1.3.6.1.4.1.13742.4.2.2.1.9 | DisplayString | read-write | The value of Y coordinate in freeform with number of characters <= 24 This is deprecated in favor of externalSensors |
| STR tempZCoordinate | 1.3.6.1.4.1.13742.4.2.2.1.10 | DisplayString | read-write | The value of Z coordinate in one of two formats: either freeform with number of characters <= 24 or in Z units so that 0 =< integer value <= 60 This is deprecated in favor of externalSensors |
| I32 humiditySensorCount | 1.3.6.1.4.1.13742.4.2.3 | Integer32 | read-only | The number of external humidity sensors (regardless of their current state) present on this pdu. This is deprecated in favor of externalSensors |
| humiditySensorTable | 1.3.6.1.4.1.13742.4.2.4 | not-accessible | A list of humidity sensor entries. The number of entries is given by the value of humiditySensorCount. This is deprecated in favor of externalSensors | |
| humiditySensorEntry | 1.3.6.1.4.1.13742.4.2.4.1 | not-accessible | An entry containing sensor reading and threshold settings for a particular humidity sensor. This is deprecated in favor of externalSensors | |
| I32 humiditySensorIndex | 1.3.6.1.4.1.13742.4.2.4.1.1 | Integer32 | not-accessible | A unique value for each humidity sensor. Its value ranges between 1 and humiditySensorCount. This is deprecated in favor of externalSensors |
| STR humiditySensorLabel | 1.3.6.1.4.1.13742.4.2.4.1.2 | DisplayString | read-write | A settable human-readable label for the external humidity sensor. One possible use for this label is to convey sensor location. This is deprecated in favor of externalSensors |
| REL humidity | 1.3.6.1.4.1.13742.4.2.4.1.3 | RelativeHumidity | read-only | The value of the external humidity sensor reported as relative humidity (a percentage). This is deprecated in favor of externalSensors |
| REL humidityLowerWarning | 1.3.6.1.4.1.13742.4.2.4.1.4 | RelativeHumidity | read-write | The value of the lower warning (non-critical) threshold. This is deprecated in favor of externalSensors |
| REL humidityUpperWarning | 1.3.6.1.4.1.13742.4.2.4.1.5 | RelativeHumidity | read-write | The value of the upper warning (non-critical) threshold. This is deprecated in favor of externalSensors |
| REL humidityLowerCritical | 1.3.6.1.4.1.13742.4.2.4.1.6 | RelativeHumidity | read-write | The value of the lower critical threshold. This is deprecated in favor of externalSensors |
| REL humidityUpperCritical | 1.3.6.1.4.1.13742.4.2.4.1.7 | RelativeHumidity | read-write | The value of the upper critical threshold. This is deprecated in favor of externalSensors |
| STR humidityXCoordinate | 1.3.6.1.4.1.13742.4.2.4.1.8 | DisplayString | read-write | The value of X coordinate in freeform with number of characters <= 24 This is deprecated in favor of externalSensors |
| STR humidityYCoordinate | 1.3.6.1.4.1.13742.4.2.4.1.9 | DisplayString | read-write | The value of Y coordinate in freeform with number of characters <= 24 This is deprecated in favor of externalSensors |
| STR humidityZCoordinate | 1.3.6.1.4.1.13742.4.2.4.1.10 | DisplayString | read-write | The value of Z coordinate in one of two formats: either freeform with number of characters <= 24 or in Z units so that 0 =< integer value <= 60 This is deprecated in favor of externalSensors |
| externalSensors | 1.3.6.1.4.1.13742.4.3 | |||
| I32 externalSensorCount | 1.3.6.1.4.1.13742.4.3.1 | Integer32 | read-only | The number of external sensors |
| STR reorderexternalSensorTableEntries | 1.3.6.1.4.1.13742.4.3.2 | DisplayString | read-write | This is an operation. It has write-only semantics. GET operation will return the empty string. For SET operations, it specifies the new order of the externalSensorTable entries. a) The list must contain entries for each managed sensor, even if the sensor is not being moved. b) The list must not have more than 16 entries. c) 1 13 2 --> 8 3 --> 9 4 --> 4 5 --> 2 Since the largest sensorID before the move is 5, the length of the list is 5 Comma separated list is 13,8,9,4,2 EXAMPLE 2: Managed sensors have IDs 2,5,6,7,11 Sensor IDs 1,3,4,8,9,10 do not appear in the list. These positions must be indicated by commas. Move 2 to 13; 5 to 8; 6 to 9; 7 to 16; 11 does not move Existing Position New Position 2 --> 13 5 --> 8 6 --> 9 7 --> 16 11 --> 11 Since the largest sensorID before the move is 11, the length of the list is 11 Comma separated list is ,13,,,8,9,16,,,,11 |
| externalSensorTable | 1.3.6.1.4.1.13742.4.3.3 | not-accessible | A list of externalSensor entries. The number of entries is given by the value of externalSensorCount for the pdu. | |
| externalSensorEntry | 1.3.6.1.4.1.13742.4.3.3.1 | not-accessible | An externalSensor entry containing objects at the for a particular PDU. | |
| I32 sensorID | 1.3.6.1.4.1.13742.4.3.3.1.1 | Integer32 | not-accessible | A unique value for each sesnor. Its value ranges between 1 and the value of externalSensorCount. |
| TYP externalSensorType | 1.3.6.1.4.1.13742.4.3.3.1.2 | TypeOfSensorEnumeration | read-only | The type of sensor |
| STR externalSensorSerialNumber | 1.3.6.1.4.1.13742.4.3.3.1.3 | DisplayString | read-only | The sensor serial number |
| STR externalSensorName | 1.3.6.1.4.1.13742.4.3.3.1.4 | DisplayString | read-write | The user given name |
| I32 externalSensorChannelNumber | 1.3.6.1.4.1.13742.4.3.3.1.5 | Integer32 | read-only | The channel number, applies only to contact sensors; -1 for other sensors |
| STR externalSensorXCoordinate | 1.3.6.1.4.1.13742.4.3.3.1.6 | DisplayString | read-write | The X coordinate |
| STR externalSensorYCoordinate | 1.3.6.1.4.1.13742.4.3.3.1.7 | DisplayString | read-write | The Y coordinate |
| STR externalSensorZCoordinate | 1.3.6.1.4.1.13742.4.3.3.1.8 | DisplayString | read-write | The Z coordinate |
| TYP externalBinarySensorSubtype | 1.3.6.1.4.1.13742.4.3.3.1.9 | TypeOfSensorEnumeration | read-only | The subtype of the binary sensor This OID is valid for discrete sensors only. |
| SEN externalSensorUnits | 1.3.6.1.4.1.13742.4.3.3.1.16 | SensorUnitsEnumeration | read-only | The base units. Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors |
| U32 externalSensorDecimalDigits | 1.3.6.1.4.1.13742.4.3.3.1.17 | Unsigned32 | read-only | The number of digits displayed to the right of the decimal point. Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors |
| I32 externalSensorLowerCriticalThreshold | 1.3.6.1.4.1.13742.4.3.3.1.31 | Integer32 | read-write | The lower critical threshold The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is .01 Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors |
| I32 externalSensorLowerWarningThreshold | 1.3.6.1.4.1.13742.4.3.3.1.32 | Integer32 | read-write | The lower non-critical (warning) threshold The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is .01 Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors |
| I32 externalSensorUpperCriticalThreshold | 1.3.6.1.4.1.13742.4.3.3.1.33 | Integer32 | read-write | The upper critical threshold The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is .01 Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors |
| I32 externalSensorUpperWarningThreshold | 1.3.6.1.4.1.13742.4.3.3.1.34 | Integer32 | read-write | The upper non-critical (warning) threshold The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is .01 Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors |
| U32 externalSensorHysteresis | 1.3.6.1.4.1.13742.4.3.3.1.35 | Unsigned32 | read-write | The hysteresis used for deassertions The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to onOff, trip, vibration, waterDetection, smokeDetection sensors. |
| STA externalSensorState | 1.3.6.1.4.1.13742.4.3.3.1.40 | StateOfSensorEnumeration | read-only | The sensor state |
| I32 externalSensorValue | 1.3.6.1.4.1.13742.4.3.3.1.41 | Integer32 | read-only | The sensor reading Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors |
| compliances | 1.3.6.1.4.1.13742.4.9.1 | |||
| compliance | 1.3.6.1.4.1.13742.4.9.1.1 | The requirements for conformance to the PDU-MIB. This is deprecated and the new compliance ComplianceRev1 has been added | ||
| complianceRev1 | 1.3.6.1.4.1.13742.4.9.1.2 | The requirements for conformance to the PDU-MIB. This is deprecated and the new compliance ComplianceRev2 has been added | ||
| complianceRev2 | 1.3.6.1.4.1.13742.4.9.1.3 | The requirements for conformance to the PDU-MIB. This is deprecated and the new compliance ComplianceRev3 has been added | ||
| complianceRev3 | 1.3.6.1.4.1.13742.4.9.1.4 | The requirements for conformance to the PDU-MIB.This is deprecated and the new compliance ComplianceRev4 has been added | ||
| complianceRev4 | 1.3.6.1.4.1.13742.4.9.1.5 | The requirements for conformance to the PDU-MIB. This is deprecated and the new compliance ComplianceRev5 has been added | ||
| complianceRev5 | 1.3.6.1.4.1.13742.4.9.1.6 | The requirements for conformance to the PDU-MIB. | ||
| groups | 1.3.6.1.4.1.13742.4.9.2 | |||
| infoGroup | 1.3.6.1.4.1.13742.4.9.2.1 | A collection of objects providing basic information about the pdu. | ||
| outletsGroup | 1.3.6.1.4.1.13742.4.9.2.2 | A collection of objects providing basic information about the outlets, including sensor readings. | ||
| unitSensorsGroup | 1.3.6.1.4.1.13742.4.9.2.4 | A collection of objects providing unit level sensor readings.This group is deprecated in favor of unitSensorsGroupRev | ||
| externalTemperatureGroup | 1.3.6.1.4.1.13742.4.9.2.6 | A collection of objects providing external temperature sensor readings and threshold settings. This group is deprecated in favor of the externalSensorsGroup | ||
| externalHumidityGroup | 1.3.6.1.4.1.13742.4.9.2.7 | A collection of objects providing external humidity sensor readings and threshold settings. This group is deprecated in favor of the externalSensorsGroup | ||
| trapsGroup | 1.3.6.1.4.1.13742.4.9.2.9 | A collection of traps. | ||
| lineCurrentGroup | 1.3.6.1.4.1.13742.4.9.2.10 | A collection of objects describing the line inputs. This group is deprecated in favor of inletPoleGroup | ||
| circuitBreakerGroup | 1.3.6.1.4.1.13742.4.9.2.11 | A collection of objects describing the circuit breakers. | ||
| lineVoltageGroup | 1.3.6.1.4.1.13742.4.9.2.12 | A collection of objects describing the line voltages. This group is deprecated in favor of inletPoleGroup | ||
| unitSensorsGroupRev | 1.3.6.1.4.1.13742.4.9.2.13 | A collection of objects providing unit level sensor readings.This group is deprecated in favor of unitSensorsGroupRev2 | ||
| dataLogGroup | 1.3.6.1.4.1.13742.4.9.2.14 | A collection of objects describing the pdu data. This group is being deprecated in favor of dataLogGroupRev | ||
| inletPoleGroup | 1.3.6.1.4.1.13742.4.9.2.15 | A collection of objects describing the inlet poles. | ||
| inletsGroup | 1.3.6.1.4.1.13742.4.9.2.16 | A collection of objects providing basic information about the inlets, including sensor readings. | ||
| dataLogGroupRev | 1.3.6.1.4.1.13742.4.9.2.17 | A collection of objects describing the pdu data. This group is being deprecated in favor of dataLogGroupRev2 | ||
| unitSensorsGroupRev2 | 1.3.6.1.4.1.13742.4.9.2.18 | A collection of objects providing unit level sensor readings. | ||
| externalSensorsGroup | 1.3.6.1.4.1.13742.4.9.2.20 | A collection of objects providing external sensor readings and configuration settings. | ||
| dataLogGroupRev2 | 1.3.6.1.4.1.13742.4.9.2.21 | A collection of objects describing the pdu data. | ||
| infoGroupRev2 | 1.3.6.1.4.1.13742.4.9.2.22 | A collection of objects providing basic information about the pdu. |
RFC description
Monitors Raritan Power Distribution Units including power, environmental sensors, and outlet management.
Start monitoring Raritan Dominion PX intelligent power distribution unit (PDU) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.