| OID symbolic | OID numeric | Type | Access | Description |
| powerEthernetMIB | 1.3.6.1.4.1.193.72.601 | | | The MIB module for for managing Powered Devices (PD) or
Power Source Equipment (PSE) working according to the IEEE
802.af Powered Ethernet (DTE Power via MDI) standard.
The following terms are used throughout this
MIB module. For complete formal definitions,
the IEEE 802.3 standards should be consulted
wherever possible:
Group - A recommended, but optional, entity
defined by the IEEE 802.3 management standard,
in order to support a modular numbering scheme.
The classical example allows an implementor to
represent field-replaceable units as groups of
ports, with the port numbering matching the
modular hardware implementation.
Port - This entity identifies the port within the group
for which this entry contains information. The numbering
scheme for ports is implementation specific.
REVISION HISTORY:-
REV DATE NAME DESCRIPTION
A 030225 DXDPJN Put into Ericsson private MIB tree. |
| pethNotifications | 1.3.6.1.4.1.193.72.601.0 | | | |
| NTF pethPsePortOnOffNotification | 1.3.6.1.4.1.193.72.601.0.1 | | | This Notification indicates if Pse Port is delivering or
not power to the PD. This Notification SHOULD be sent on
every status change except in the searching mode. |
| NTF pethPsePortPowerMaintenanceStatusNotification | 1.3.6.1.4.1.193.72.601.0.2 | | | This Notification indicates a Port Change Status and it
SHOULD be sent on every status change. |
| NTF pethMainPowerUsageOnNotification | 1.3.6.1.4.1.193.72.601.0.4 | | | This Notification indicate PSE Threshold usage indication is
on, the usage power is above the threshold. |
| NTF pethMainPowerUsageOffNotification | 1.3.6.1.4.1.193.72.601.0.5 | | | This Notification indicate PSE Threshold usage indication
off, the usage power is below the threshold. |
| pethObjects | 1.3.6.1.4.1.193.72.601.1 | | | |
| pethPsePortTable | 1.3.6.1.4.1.193.72.601.1.1 | | not-accessible | A table of objects that display and control the power
characteristics power Ethernet ports on a Power Source
Entity (PSE) device. This group will be implemented in
managed power Ethernet switches and mid-span devices. |
| pethPsePortEntry | 1.3.6.1.4.1.193.72.601.1.1.1 | | not-accessible | A set of objects that display and control the power
characteristics of a power Ethernet PSE port. |
| I32 pethPsePortGroupIndex | 1.3.6.1.4.1.193.72.601.1.1.1.1 | Integer32 | not-accessible | This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is connected.
Group means box in the stack, module in a rack and the value 1
MUST be used for non-modular devices .
pethPseMidSpanGroupCapacity is the number of Mid-Span PSE
groups that can be contained within the Mid-Span PSE. |
| I32 pethPsePortIndex | 1.3.6.1.4.1.193.72.601.1.1.1.2 | Integer32 | not-accessible | This variable uniquely identifies the power Ethernet PSE
port within group pethPseGroupIndex to which the
power Ethernet PSE entry is connected. |
| INT pethPsePortAdminEnable | 1.3.6.1.4.1.193.72.601.1.1.1.3 | INTEGER | read-write | Enables power supply on this port.
Setting this object at a value enable(1) enables power
and detection mechanism for this port.
Setting this object at a value disable(2) disables power
for this port. |
| T/F pethPsePortPowerPairsControlAbility | 1.3.6.1.4.1.193.72.601.1.1.1.4 | TruthValue | read-only | Describes the capability of controlling the power pairs
functionality to switch pins for sourcing power.
The value true indicate that the device has the capability
to control the power pairs |
| INT pethPsePortPowerPairs | 1.3.6.1.4.1.193.72.601.1.1.1.5 | INTEGER | read-write | Describes or controls the pairs in use. If the value of
pethPsePortPowerPairsControl is true, this object is
writable.
A value of signal(1) means that the signal pairs
only are in use.
A value of spare(2) means that the spare pairs
only are in use. |
| INT pethPsePortPowerDetectionControl | 1.3.6.1.4.1.193.72.601.1.1.1.6 | INTEGER | read-write | Controls the power detection mechanism of the port.
Setting the value auto(1) enables the power detection
mechanism of the port.
Setting the value test(2) puts the port in a
testmode: force continuous discovery without applying
power regardless of whether PD detected. |
| INT pethPsePortDetectionStatus | 1.3.6.1.4.1.193.72.601.1.1.1.7 | INTEGER | read-only | Describes the operational status of the port PD detection.
A value of disabled(1)- indicates that the PSE State diagram is in
the state IDLE
A value of searching(2)- indicates that the PSE State diagram is in
the state DETECTION, CLASSIFICATION, SIGNATURE_INVALID or BACKOFF.
A value of deliveringPower(4) - indicates that the PSE State diagram
is in the state POWER_UP, POWER_ON or POWER_OFF.
A value of fault(5) - indicates that the PSE State diagram is in the
state TEST_ERROR or the state IDLE due to the variable error
condition.
Faults detected are vendor specific.
A value of test(7) - indicates that the PSE State diagram is in the
state TEST_MODE.
A value of denyLowPriority(8) indicates that the port was
disabled by the power management system, in order to keep
active higher priority ports. |
| INT pethPsePortPowerPriority | 1.3.6.1.4.1.193.72.601.1.1.1.8 | INTEGER | read-write | This object controls the priority of the port from the point
of view of a power management algorithm. The priority that
is set by this variable could be used by a control mechanism
that prevents over current situations by disconnecting first
ports with lower power priority. Ports that connect devices
critical to the operation of the network - like the E911
telephones ports - should be set to higher priority. |
| INT pethPsePortPowerMaintenanceStatus | 1.3.6.1.4.1.193.72.601.1.1.1.10 | INTEGER | read-only | The value ok(1) indicates the Power Maintenance
Signature is present and the overcurrent condition has not been
detected.
The value overCurrent (2) indicates an overcurrent condition
has been detected.
The value mPSAbsent(3) indicates that the Power Maintenance
Signature is absent. |
| C32 pethPsePortMPSAbsentCounterEx | 1.3.6.1.4.1.193.72.601.1.1.1.11 | Counter32 | read-only | Counts the number of times that the
pethPsePortPowerMaintenanceStatus attribute changes from any
value to the value mPSAbsent(3). |
| C32 pethPsePortOverCurrentCounter | 1.3.6.1.4.1.193.72.601.1.1.1.12 | Counter32 | read-only | Counts the number of times that the aPSEPowerCurrentStatus
attribute changes from any value to the value overCurrent(2). |
| INT pethPsePortType | 1.3.6.1.4.1.193.72.601.1.1.1.13 | INTEGER | read-write | A manager will set the value of this variable to a value
that indicates the type of the device that is connected
to theport. This value can be the result of the mapping
the address of the station connected to the port and of
the value of the pethPdPortType of the respective PD port. |
| INT pethPsePortPowerClassifications | 1.3.6.1.4.1.193.72.601.1.1.1.14 | INTEGER | read-only | Classification is a way to tag different terminals on the
Power over LAN network according to their power consumption.
Devices such as IP telephones, WLAN access points and others,
will be classified according to their power requirements.
The value is only valid while a valid PD is being detected as
indicated by the attribute pethPsePortDetectionStatus reporting
the value or deliveringPower(4). |
| pethPdPortTable | 1.3.6.1.4.1.193.72.601.1.2 | | not-accessible | A table of objects that display and control the power
characteristics power Ethernet ports on a Powered
Device(PD) device. This group will be implemented in
managed powered and mid-span devices. |
| pethPdPortEntry | 1.3.6.1.4.1.193.72.601.1.2.1 | | not-accessible | A set of objects that display and control the power
characteristics of a Powered Device port. |
| NUM pethPdPortIndex | 1.3.6.1.4.1.193.72.601.1.2.1.1 | InterfaceIndex | not-accessible | An index value that uniquely identifies an
interface to a PD device. The
interface identified by a particular value of
this index is the same interface as identified
by the same value of ifIndex. The mapping
between the ifIndex values and the numbering of
the port on the device is an implementation
issue. |
| INT pethPdPortAdminEnable | 1.3.6.1.4.1.193.72.601.1.2.1.2 | INTEGER | read-write | This value identifies the operational state of the PD functions.
An interface which can provide the PD functions will be enabled
to do so when this attribute has the value enable. When this
attribute has the value disable the interface will act
as it would if it had no PD function. |
| pethMainPseObjects | 1.3.6.1.4.1.193.72.601.1.3 | | | |
| pethMainPseTable | 1.3.6.1.4.1.193.72.601.1.3.1 | | not-accessible | A table of objects that display and control the Main power
on a PSE device. Example - an Ethernet switch midspan device can
control an Ethnternet port and the Main Power supply unit's. |
| pethMainPseEntry | 1.3.6.1.4.1.193.72.601.1.3.1.1 | | not-accessible | A set of objects that display and control the Main power
of a PSE. |
| I32 pethMainPseGroupIndex | 1.3.6.1.4.1.193.72.601.1.3.1.1.1 | Integer32 | not-accessible | This variable uniquely identifies the group to which
power Ethernet PSE is connected.Group means (box in the stack,
module in a rack) and the value 1 MUST be used for non-modular
devices |
| G32 pethMainPsePower | 1.3.6.1.4.1.193.72.601.1.3.1.1.2 | Gauge32 | read-only | The nominal power of the PSE expressed in Watts. |
| INT pethMainPseOperStatus | 1.3.6.1.4.1.193.72.601.1.3.1.1.3 | INTEGER | read-only | The operational status of the main PSE. |
| G32 pethMainPseConsumptionPower | 1.3.6.1.4.1.193.72.601.1.3.1.1.4 | Gauge32 | read-only | Measured usage power expressed in Watts. |
| I32 pethMainPseUsageThreshold | 1.3.6.1.4.1.193.72.601.1.3.1.1.7 | Integer32 | read-write | The usage threshold expressed in percents for
comparing the measured power and initiating
an alarm if the threshold is exceeded. |
| pethNotificationControl | 1.3.6.1.4.1.193.72.601.1.4 | | | |
| pethNotificationControlTable | 1.3.6.1.4.1.193.72.601.1.4.1 | | not-accessible | A table of objects that display and control the Notification
on a PSE device. |
| pethNotificationControlEntry | 1.3.6.1.4.1.193.72.601.1.4.1.1 | | not-accessible | A set of objects that control the Notification events. |
| I32 pethNotificationControlGroupIndex | 1.3.6.1.4.1.193.72.601.1.4.1.1.1 | Integer32 | not-accessible | This variable uniquely identifies the group. Group means
box in the stack, module in a rack and it is RECOMENDED
that the value 1 be used for non-modular devices |
| INT pethNotificationControlEnable | 1.3.6.1.4.1.193.72.601.1.4.1.1.2 | INTEGER | read-write | Enable Notification from Agent |
| pethConformance | 1.3.6.1.4.1.193.72.601.2 | | | |
| pethCompliances | 1.3.6.1.4.1.193.72.601.2.1 | | | |
| pethCompliance | 1.3.6.1.4.1.193.72.601.2.1.1 | | | Describes the requirements for conformance to the
Power Ethernet MIB. |
| pethPseCompliance | 1.3.6.1.4.1.193.72.601.2.1.2 | | | Describes the requirements for conformance to the PSE and MID-
Span. |
| pethPdCompliance | 1.3.6.1.4.1.193.72.601.2.1.3 | | | Describes the requirements for conformance to the PD. |
| pethPsePortNotificationGroup | 1.3.6.1.4.1.193.72.601.2.1.4 | | | Pse Notification indications |
| pethMainPowerNotificationGroup | 1.3.6.1.4.1.193.72.601.2.1.5 | | | Pse Notification indications |
| pethGroups | 1.3.6.1.4.1.193.72.601.2.2 | | | |
| pethPsePortGroup | 1.3.6.1.4.1.193.72.601.2.2.1 | | | The pethPsePortGroup is mandatory for systems which
implement PSE ports. |
| pethPdPortGroup | 1.3.6.1.4.1.193.72.601.2.2.2 | | | The pethPdPortGroup is mandatory for systems which
implement PD Ports. |
| pethMainPseGroup | 1.3.6.1.4.1.193.72.601.2.2.3 | | | Main PSE Objects. |
| pethNotificationControlGroup | 1.3.6.1.4.1.193.72.601.2.2.4 | | | Notification Control Objects. |