| OID symbolic | OID numeric | Type | Access | Description |
| polPowerOverLan | 1.3.6.1.4.1.7428 | | | |
| products | 1.3.6.1.4.1.7428.1 | | | |
| description | 1.3.6.1.4.1.7428.1.1 | | | |
| sysObjectID | 1.3.6.1.4.1.7428.1.1.1 | | | |
| midspanUnknown | 1.3.6.1.4.1.7428.1.1.1.1 | | | |
| midspan6portAC | 1.3.6.1.4.1.7428.1.1.1.2 | | | |
| midspan6portACDC | 1.3.6.1.4.1.7428.1.1.1.3 | | | |
| midspan12portAC | 1.3.6.1.4.1.7428.1.1.1.4 | | | |
| midspan12portACDC | 1.3.6.1.4.1.7428.1.1.1.5 | | | |
| midspan24portAC | 1.3.6.1.4.1.7428.1.1.1.6 | | | |
| midspan24portACDC | 1.3.6.1.4.1.7428.1.1.1.7 | | | |
| midspan48portAC | 1.3.6.1.4.1.7428.1.1.1.8 | | | |
| midspan48portACDC | 1.3.6.1.4.1.7428.1.1.1.9 | | | |
| midspan6portHPAC | 1.3.6.1.4.1.7428.1.1.1.10 | | | |
| midspan6portHPACDC | 1.3.6.1.4.1.7428.1.1.1.11 | | | |
| midspan12portHPAC | 1.3.6.1.4.1.7428.1.1.1.12 | | | |
| midspan12portHPACDC | 1.3.6.1.4.1.7428.1.1.1.13 | | | |
| midspanGigabit6portAC | 1.3.6.1.4.1.7428.1.1.1.14 | | | |
| midspanGigabit12portAC | 1.3.6.1.4.1.7428.1.1.1.15 | | | |
| midspanGigabit24portAC | 1.3.6.1.4.1.7428.1.1.1.16 | | | |
| midspanHiPoEGigabit6portAC | 1.3.6.1.4.1.7428.1.1.1.17 | | | |
| midspanHiPoEGigabit12portAC | 1.3.6.1.4.1.7428.1.1.1.18 | | | |
| midspanHiPoEGigabit24portAC | 1.3.6.1.4.1.7428.1.1.1.19 | | | |
| midspanHiPoEATGigabit6portAC | 1.3.6.1.4.1.7428.1.1.1.20 | | | |
| midspanHiPoEATGigabit12portACDC | 1.3.6.1.4.1.7428.1.1.1.21 | | | |
| midspanHiPoEATGigabit24portACDC | 1.3.6.1.4.1.7428.1.1.1.22 | | | |
| midspan4PairATGigabit6portACDC | 1.3.6.1.4.1.7428.1.1.1.23 | | | |
| midspan4PairATGigabit12portACDC | 1.3.6.1.4.1.7428.1.1.1.24 | | | |
| midspanHiPoEATGigabit6portDC | 1.3.6.1.4.1.7428.1.1.1.25 | | | |
| midspanHiPoEATGigabit12portDC | 1.3.6.1.4.1.7428.1.1.1.26 | | | |
| midspanHiPoEATGigabit24portDC | 1.3.6.1.4.1.7428.1.1.1.27 | | | |
| midspan4PairATGigabit24portACDC | 1.3.6.1.4.1.7428.1.1.1.28 | | | |
| midspanEEPoEGigabit24portACDC | 1.3.6.1.4.1.7428.1.1.1.29 | | | |
| midspanPoHGigabit6portACDC | 1.3.6.1.4.1.7428.1.1.1.30 | | | |
| midspanPoHGigabit12portACDC | 1.3.6.1.4.1.7428.1.1.1.31 | | | |
| midspanPoHGigabit24portACDC | 1.3.6.1.4.1.7428.1.1.1.32 | | | |
| pseDevice | 1.3.6.1.4.1.7428.1.2 | | | |
| portObjects | 1.3.6.1.4.1.7428.1.2.1 | | | |
| portTable | 1.3.6.1.4.1.7428.1.2.1.1 | | not-accessible | A table of objects that display and control the power
characteristics of power Ethernet ports on a Power Source
Entity (PSE) device. This group will be implemented in
managed power Ethernet switches and mid-span devices.
Values of all read-write objects in this table are
persistent at restart/reboot. |
| portEntry | 1.3.6.1.4.1.7428.1.2.1.1.1 | | not-accessible | A set of objects that display and control the power
characteristics of a power Ethernet PSE port. |
| I32 portGroupIndex | 1.3.6.1.4.1.7428.1.2.1.1.1.1 | Integer32 | not-accessible | This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected. Group means box in the stack, module in a
rack and the value 1 MUST be used for non-modular devices. |
| I32 portIndex | 1.3.6.1.4.1.7428.1.2.1.1.1.2 | Integer32 | not-accessible | This variable uniquely identifies the power Ethernet PSE
port within group portGroupIndex to which the
power Ethernet PSE entry is connected. |
| G32 portConsumptionPowerEx | 1.3.6.1.4.1.7428.1.2.1.1.1.3 | Gauge32 | read-only | A read-only value indicates the measured usage power expressed in Watts for a specific port |
| I32 portMaxPower | 1.3.6.1.4.1.7428.1.2.1.1.1.4 | Integer32 | read-write | Read/Write maximum power consumption that PD device may consume in Watts
NOTE:
1. For Midspan 60xx,60xxG,6500 series, Max PD power consumption = 17Watt
2. For Midspan 70xxG series, Max PD power consumption = 30Watt
3 .For Midspan 80xx series, this parameter is read-only !!
4. For Midspan 90xxG series, Max PD power consumption = 30/36Watt
5. For Midspan 95xxG series, Max PD power consumption = 60/72Watt (four pair) or 30/36Watt (two pair)
6. For Midspan 55xxG series, Max PD power consumption = 30/36Watt |
| INT portType | 1.3.6.1.4.1.7428.1.2.1.1.1.5 | INTEGER | read-write | Enable/Disable Four-pair/EEPoE PoE
Read : Applicable to all Midspan series
Write: Applicable only to 95xxG/55xxG Midspan series
twopair (1) Two-pair PoE port capable of providing up to 16.8Watt or 30-36Watt.
fourpair (2) Four-pair/EEPoE-mode PoE port capable of providing up to 60-72Watt (95xxG) or 30-36W (55xxG). |
| mainObjects | 1.3.6.1.4.1.7428.1.2.2 | | | |
| mainPseTable | 1.3.6.1.4.1.7428.1.2.2.1 | | not-accessible | A table of objects that display and control attributes
of the main PSE device. |
| mainPseEntry | 1.3.6.1.4.1.7428.1.2.2.1.1 | | not-accessible | A set of objects that display and control the Main PSE device. |
| I32 mainGroupIndex | 1.3.6.1.4.1.7428.1.2.2.1.1.1 | Integer32 | not-accessible | This variable uniquely identifies the group to which
power Ethernet PSE is connected. Group means (box in
the stack, module in a rack) and the value 1 MUST be
used for non-modular devices. |
| G32 mainVoltage | 1.3.6.1.4.1.7428.1.2.2.1.1.2 | Gauge32 | read-only | Power Supply Voltage in Volt. |
| INT mainDetectionMethod | 1.3.6.1.4.1.7428.1.2.2.1.1.3 | INTEGER | read-write | Read/Write PD device detection method (802.3af / 802.3af+Legacy). |
| I32 mainPowerUsageBudget | 1.3.6.1.4.1.7428.1.2.2.1.1.4 | Integer32 | read-write | Allow external SNMP manager to limit maximum power that all PD's may consume
Whenever total power consumption exceeds maximum power, Midspan may turn off
automatically Low priority and High priority PSE ports.
Percentage Value refers to Midspan maximum power. |
| G32 mainPSEMaxPower | 1.3.6.1.4.1.7428.1.2.2.1.1.5 | Gauge32 | read-only | Maximum power that Midspan can provide (Watt), after including power budget percentage limitation.
Example: Midspan maximum power without power limit = 860Watt, and Power Limit = 50%
mainPSEMaxPower = 430Watt |
| INT highPowerLegacyPDSupport | 1.3.6.1.4.1.7428.1.2.2.1.1.6 | INTEGER | read-write | Applicable only for Midspan 90xxG series
enable (1) - Power Cisco 125x access point (pre 802.3at legacy high power PD device).
disable(2) - Power only 802.3at compliant devices.
notsupported(3) - SNMP GET result for Midspan which doesn't support this feature |
| INT highPowerExtendedPortPower | 1.3.6.1.4.1.7428.1.2.2.1.1.7 | INTEGER | read-write | Applicable only for Midspan 90xxG/55xxG series
enable (1) - Extend maximum power to PD device beyond 802.3at specification.
disable(2) - Maximum power to PD device per 802.3at specification.
notsupported(3) - SNMP GET result for Midspan which doesn't support this feature |
| INT powerBackupStatus | 1.3.6.1.4.1.7428.1.2.2.1.1.8 | INTEGER | read-only | Applicable only for Midspan 90xxG/95xxG/55xxG series
standalone - Midspan isn't connected to any power backup device
powerbackupbyrps - Redundant power supply (RPS) backup Midspan device
powerbackupbymidspan - Two Midspan devices backup each other
incompatiblepowerbackupdevice - Midspan was connected to incompatible power backup device.
For example RPS 430Watt to Midspan 950Watt |
| INT internalPowerSourceStatus | 1.3.6.1.4.1.7428.1.2.2.1.1.9 | INTEGER | read-only | Applicable only for Midspan 90xxG/95xxG/55xxG series
ok(1) - Internal Power Source is OK
fail(2) - Internal Power Source failure |
| INT externalPowerSourceStatus | 1.3.6.1.4.1.7428.1.2.2.1.1.10 | INTEGER | read-only | Applicable only for Midspan 90xxG/95xxG/55xxG series
ok(1) - External Power Source is OK
fail(2) - External Power Source failure
notsupported(3) - SNMP GET result for Midspan which doesn't support this feature |
| INT temperature | 1.3.6.1.4.1.7428.1.2.2.1.1.11 | INTEGER | read-only | Unit temperature - Applicable only for Midspan 95xxG series |
| INT temperatureformat | 1.3.6.1.4.1.7428.1.2.2.1.1.12 | INTEGER | read-write | Unit temperature format - Applicable only for Midspan 95xxG series
Celcius(1) - Report unit temperature in Celcius
Fahrenheit(2) - Report unit temperature in Fahrenheit
NotSupported(3) - No temperature sensor inside the Midspan unit |
| poeNotifications | 1.3.6.1.4.1.7428.1.3 | | | |
| NTF powerBackupStatusNotification | 1.3.6.1.4.1.7428.1.3.1 | | | Applicable only for Midspan 90xxG/95xxG/55xxG series
This Notification reports power backup status change, and whenever incompatible
power backup source is connected (as RPS 430Watt to Midspan 950Watt) |
| NTF internalPowerSourceStatusNotification | 1.3.6.1.4.1.7428.1.3.2 | | | Applicable only for Midspan 90xxG/95xxG/55xxG series
This Notification reports internal Power Source failure |
| NTF externalPowerSourceStatusNotification | 1.3.6.1.4.1.7428.1.3.3 | | | Applicable only for Midspan 90xxG/95xxG/55xxG series
This Notification reports external Power Source failure |