Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2RX1000-MIB?
OMNI-gx2RX1000-MIB is a vendor-specific SNMP module for the Cisco/Scientific-Atlanta GX2 RX1000, a 1000 MHz optical receiver card used in hybrid fiber-coax (HFC) optical node deployments within cable television and broadband access networks. Although no sample objects were captured, an optical receiver card MIB of this kind typically models the card's optical input level, RF output level, module temperature, and operational/alarm status. Its monitoring emphasis would be hardware health of the optical receiver: tracking whether received optical power is within range, whether the card is reporting a fault or alarm, and general operational state, which is critical for detecting fiber cuts, laser degradation, or node hardware failure in an HFC plant. As part of the broader Scientific-Atlanta/Cisco optical node product line, it likely coexists with related OMNI-series MIBs covering the node housing and other cards in the same chassis. It is typically deployed by cable operators managing fiber node sites feeding coax distribution networks. Engineers can download the OMNI-gx2RX1000-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2RX1000-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 RX1000 1000 MHz optical receiver card)
Monitoring Examples
Because sample objects were not available for this module, a concrete monitoring scenario cannot be honestly constructed from confirmed object names; in practice an operator would expect to poll optical receive-level, RF output, temperature, and alarm/status objects for the GX2 RX1000 card to detect fiber signal degradation or card hardware faults at an HFC node site. This description is based on the card's known function (a 1000 MHz optical receiver) rather than on verified MIB object names.
What Can Be Monitored
- optical receive signal level (expected)
- RF output level (expected)
- card temperature (expected)
- card operational/alarm status (expected)
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Rx1000 | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapRX1000ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.9.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapRX1000ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.9.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapRX1000OpticalPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.9.0.3 | This trap is issued when the input Optical Power parameter goes out of range. | ||
| NTF trapRX1000ModuleTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.9.0.4 | This trap is issued when the RX1000 Module's Temperature goes out of range. | ||
| NTF trapRX1000HeatSinkTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.9.0.5 | This trap is issued when the RX1000 Heat Sink Temperature goes out of range. | ||
| NTF trapRX1000FanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.9.0.6 | This trap is issued when the RX1000 Module's Fan Currrent parameter goes out of range. | ||
| NTF trapRX1000Plus12CurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.9.0.7 | This trap is issued when the RX1000 Module's positive 12 volt current parameter goes out of range. | ||
| NTF trapRX1000OpticalSwitchAlarm | 1.3.6.1.4.1.1166.6.1.2.9.0.8 | This trap is issued when the RX1000 Redundancy signal indicates a low input signal. | ||
| NTF trapRX1000Boot0Alarm | 1.3.6.1.4.1.1166.6.1.2.9.0.9 | This trap is issued when the RX1000 Module's Bank 0 Boot sequence has detected an error. | ||
| NTF trapRX1000Boot1Alarm | 1.3.6.1.4.1.1166.6.1.2.9.0.10 | This trap is issued when the RX1000 Module's Bank 1 Boot sequence has detected an error. | ||
| NTF trapRX1000FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.9.0.11 | This trap is issued when the RX1000 Module's boot or flash programming sequence has detected a Flash error. | ||
| NTF trapRX1000AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.9.0.12 | This trap is issued when the RX1000 Module detects an error calculating the alarm limit CRC. | ||
| NTF trapRX1000FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.9.0.13 | This trap is issued when the RX1000 Module detects an error calculating the Factory data CRC. | ||
| NTF trapRX1000CalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.9.0.14 | This trap is issued when the RX1000 Module detects an error calculating the Calibration data CRC. | ||
| NTF trapRX1000ResetFacDefault | 1.3.6.1.4.1.1166.6.1.2.9.0.15 | This trap is issued when the RX1000 resets to factory defaults | ||
| NTF trapRX1000FacCalSettingCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.9.0.16 | This trap is issued when the RX1000 Module detects factory calibration setting CRC alarm. | ||
| gx2Rx1000Descriptor | 1.3.6.1.4.1.1166.6.1.2.9.1 | |||
| gx2Rx1000AnalogTable | 1.3.6.1.4.1.1166.6.1.2.9.2 | not-accessible | This table contains gx2Rx1000 specific parameters with nominal and current values. | |
| gx2Rx1000AnalogEntry | 1.3.6.1.4.1.1166.6.1.2.9.2.1 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT fprgx2Rx1000AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.9.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR fprlabelOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR fpruomOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO fprmajorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprmajorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprminorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprminorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprcurrentValueOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.8 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT fprstateFlagOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO fprminValueOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.10 | Float | read-only | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprmaxValueOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.11 | Float | read-only | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT fpralarmStateOptPower | 1.3.6.1.4.1.1166.6.1.2.9.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR fprlabelModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR fpruomModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO fprmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.19 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT fprstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO fprminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.21 | Float | read-only | The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.22 | Float | read-only | The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT fpralarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR fprlabelSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR fpruomSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO fprmajorHighSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprmajorLowSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprminorHighSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprminorLowSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprcurrentValueSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.30 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT fprstateFlagSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO fprminValueSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.32 | Float | read-only | The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprmaxValueSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.33 | Float | read-only | The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT fpralarmStateSinkTemp | 1.3.6.1.4.1.1166.6.1.2.9.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR fprlabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR fpruomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO fprmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprcurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.41 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT fprstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO fprminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.43 | Float | read-only | The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.44 | Float | read-only | The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT fpralarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.9.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR fprlabel12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.46 | DisplayString | read-only | The value of this object provides the label of the 12v Current Analog parameter. |
| STR fpruom12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO fprmajorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprmajorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprminorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprminorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprcurrentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.52 | Float | read-only | The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT fprstateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.53 | INTEGER | read-only | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO fprminValue12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.54 | Float | read-only | The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO fprmaxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.55 | Float | read-only | The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT fpralarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.9.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| gx2Rx1000DigitalTable | 1.3.6.1.4.1.1166.6.1.2.9.3 | not-accessible | This table contains gx2Rx1000 specific parameters with nominal and current values. | |
| gx2Rx1000DigitalEntry | 1.3.6.1.4.1.1166.6.1.2.9.3.2 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT fprgx2Rx1000DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.9.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR fprlabelSlopeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.2 | DisplayString | read-only | The value of this object provides the label of the RX1000's AttnSetting Digital parameter. |
| STR fprenumSlopeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0. |
| INT fprvalueSlopeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 6. Each increment represents 1/2 dB of slope from 0 to 3 dB. Where 0 = 0db and 6 = 3db |
| INT fprstateFlagSlopeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR fprlabelAttnSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.6 | DisplayString | read-only | The value of this object provides the label of the RX1000's AttnSetting Digital parameter. |
| STR fprenumAttnSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0. |
| INT fprvalueAttnSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/4 dB of attenuation from 0 to 10 dB. Where 0 = 0db and 40 = 10db |
| INT fprstateFlagAttnSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR fprlabelWavelength | 1.3.6.1.4.1.1166.6.1.2.9.3.2.10 | DisplayString | read-only | The value of this object provides the label of the RX1000's Wavelength Digital parameter. |
| STR fprenumWavelength | 1.3.6.1.4.1.1166.6.1.2.9.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. The first value has a enumerated value of 0. |
| INT fprvalueWavelength | 1.3.6.1.4.1.1166.6.1.2.9.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT fprstateFlagWavelength | 1.3.6.1.4.1.1166.6.1.2.9.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR fprlabelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.9.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR fprenumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.9.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT fprvalueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.9.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT fprstateFlagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.9.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR fprlabelSwModeThreshold | 1.3.6.1.4.1.1166.6.1.2.9.3.2.18 | DisplayString | read-only | The value of this object provides the label of the RX1000's Switch Mode Threshold Digital parameter. |
| STR fprenumSwModeThreshold | 1.3.6.1.4.1.1166.6.1.2.9.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. The first value has a enumerated value of 0. |
| INT fprvalueSwModeThreshold | 1.3.6.1.4.1.1166.6.1.2.9.3.2.20 | INTEGER | read-write | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 0.5 dB increments ranging from -9 to +1 dB. The user can enter a number from 0 to 20, where 0 = -9db and 20= +1db |
| INT fprstateFlagSwModeThreshold | 1.3.6.1.4.1.1166.6.1.2.9.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR fprlabelSwModeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.22 | DisplayString | read-only | The value of this object provides the label of the RX1000's Switch Mode Setting Digital parameter. |
| STR fprenumSwModeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0. |
| INT fprvalueSwModeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.24 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT fprstateFlagSwModeSetting | 1.3.6.1.4.1.1166.6.1.2.9.3.2.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Rx1000StatusTable | 1.3.6.1.4.1.1166.6.1.2.9.4 | not-accessible | This table contains gx2Rx1000 specific parameters with nominal and current values. | |
| gx2Rx1000StatusEntry | 1.3.6.1.4.1.1166.6.1.2.9.4.3 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT fprgx2Rx1000StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.9.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR fprlabelBoot | 1.3.6.1.4.1.1166.6.1.2.9.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT fprvalueBoot | 1.3.6.1.4.1.1166.6.1.2.9.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT fprstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.9.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR fprlabelFlash | 1.3.6.1.4.1.1166.6.1.2.9.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT fprvalueFlash | 1.3.6.1.4.1.1166.6.1.2.9.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT fprstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.9.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR fprlabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT fprvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT fprstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR fprlabelAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Alarm Data CRC Status parameter. |
| INT fprvalueAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT fprstateflagAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR fprlabelCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| INT fprvalueCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT fprstateflagCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR fprlabelFacCalSettingCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Factor Cal Setting CRC Status parameter. |
| INT fprvalueFacCalSettingCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT fprstateflagFacCalSettingCRC | 1.3.6.1.4.1.1166.6.1.2.9.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR fprlabelInputSig | 1.3.6.1.4.1.1166.6.1.2.9.4.3.20 | DisplayString | read-only | The value of this object provides the label of the Input Sig Status parameter. |
| INT fprvalueInputSig | 1.3.6.1.4.1.1166.6.1.2.9.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT fprstateflagInputSig | 1.3.6.1.4.1.1166.6.1.2.9.4.3.22 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Rx1000FactoryTable | 1.3.6.1.4.1.1166.6.1.2.9.5 | not-accessible | This table contains gx2Rx1000 specific parameters with nominal and current values. | |
| gx2Rx1000FactoryEntry | 1.3.6.1.4.1.1166.6.1.2.9.5.4 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT fprgx2Rx1000FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.9.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT fprbootControlByte | 1.3.6.1.4.1.1166.6.1.2.9.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT fprbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.9.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT fprbank0CRC | 1.3.6.1.4.1.1166.6.1.2.9.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT fprbank1CRC | 1.3.6.1.4.1.1166.6.1.2.9.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT fprprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.9.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT fprfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.9.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT fprcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.9.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT fprhourMeter | 1.3.6.1.4.1.1166.6.1.2.9.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT fprflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.9.5.4.10 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side A. |
| INT fprflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.9.5.4.11 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side B. |
| STR fprfwRev0 | 1.3.6.1.4.1.1166.6.1.2.9.5.4.12 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 0. |
| STR fprfwRev1 | 1.3.6.1.4.1.1166.6.1.2.9.5.4.13 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 1. |
| gx2Rx1000HoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.9.6 | not-accessible | This table contains gx2Rx1000 specific parameters with nominal and current values. | |
| gx2Rx1000HoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.9.6.5 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Rx1000HoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.9.6.5.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| INT gx2Rx1000HoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.9.6.5.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| INT gx2Rx1000HoldTimeData | 1.3.6.1.4.1.1166.6.1.2.9.6.5.3 | INTEGER | read-write | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds. |
RFC description
Manages OMNISTAR GX2RX1000 forward path receiver modules in HFC networks with device descriptors and network element monitoring.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 RX1000 1000 MHz optical receiver card) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.