OMNI-gx2oa100bd-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2OA100BD FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "1" Jan 20, 2003 --DESCRIPTION -- Added revision and description comment section -- OMNISTAR Optical Amplifier (high power, dual pump) MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2oa100bd Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2OA100BD device type. -- These parameters are common across all network elements -- from gx2oa100bd device type. -- -- The gx2oa100bd Network Elements subgroup is -- a list of gx2oa100bd type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2oa100bdTableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2oa100bd type. -- -- Both groups are mandatory for management of gx2oa100bd devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2oa100bd Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2OA100BD device type. -- These parameters are common across all network elements -- from gx2oa100bd device type. gx2OA100BDDescriptor OBJECT IDENTIFIER ::= {gx2OA100BD 1} --***************************************************************************** -- // Section: Table definitions -- gx2OA100BD Table -- Contains a list of all gx2OA100BD type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2OA100BDTableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2OA100BD type. --************************************************************************* -- // Section: Table definitions - Analog gx2OA100BDAnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2OA100BDAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2OA100B specific parameters with nominal and current values." ::= { gx2OA100BD 2 } gx2OA100BDAnalogEntry OBJECT-TYPE SYNTAX Gx2OA100BDAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2OA100BDAnalogTableIndex } ::= { gx2OA100BDAnalogTable 1} --************************************************************************* -- // Section: Table definitions - Digital gx2OA100BDDigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2OA100BDDigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2OA100B specific parameters with nominal and current values." ::= { gx2OA100BD 3 } gx2OA100BDDigitalEntry OBJECT-TYPE SYNTAX Gx2OA100BDDigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2OA100BDDigitalTableIndex } ::= { gx2OA100BDDigitalTable 2} --************************************************************************* -- // Section: Table definitions - Status gx2OA100BDStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2OA100BDStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2OA100B specific parameters with nominal and current values." ::= { gx2OA100BD 4 } gx2OA100BDStatusEntry OBJECT-TYPE SYNTAX Gx2OA100BDStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2OA100BDStatusTableIndex } ::= { gx2OA100BDStatusTable 3} --************************************************************************* -- // Section: Table definitions - Factory gx2OA100BDFactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2OA100BDFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2OA100B specific parameters with nominal and current values." ::= { gx2OA100BD 5 } gx2OA100BDFactoryEntry OBJECT-TYPE SYNTAX Gx2OA100BDFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2OA100BDFactoryTableIndex } ::= { gx2OA100BDFactoryTable 4} --************************************************************************* -- // Section: Table definitions - Hold Time gx2OA100BDHoldTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2OA100BDHoldTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2OA100BD specific parameters with nominal and current values." ::= { gx2OA100BD 6 } gx2OA100BDHoldTimeEntry OBJECT-TYPE SYNTAX Gx2OA100BDHoldTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2OA100BDHoldTimeTableIndex, gx2OA100BDHoldTimeSpecIndex } ::= { gx2OA100BDHoldTimeTable 5} --************************************************************************* -- // Section: Analog parameters Gx2OA100BDAnalogEntry ::= SEQUENCE { gx2OA100BDAnalogTableIndex INTEGER, -- // Analog parameter : Module temperature oa100bdlabelModTemp DisplayString (SIZE (0..80)), oa100bduomModTemp DisplayString (SIZE (0..80)), oa100bdmajorHighModTemp Float, oa100bdmajorLowModTemp Float, oa100bdminorHighModTemp Float, oa100bdminorLowModTemp Float, oa100bdcurrentValueModTemp Float, oa100bdstateFlagModTemp INTEGER, oa100bdminValueModTemp Float, oa100bdmaxValueModTemp Float, oa100bdalarmStateModTemp INTEGER, -- // Analog parameter : Optical input power oa100bdlabelOptInPower DisplayString (SIZE (0..80)), oa100bduomOptInPower DisplayString (SIZE (0..80)), oa100bdmajorHighOptInPower Float, oa100bdmajorLowOptInPower Float, oa100bdminorHighOptInPower Float, oa100bdminorLowOptInPower Float, oa100bdcurrentValueOptInPower Float, oa100bdstateFlagOptInPower INTEGER, oa100bdminValueOptInPower Float, oa100bdmaxValueOptInPower Float, oa100bdalarmStateOptInPower INTEGER, -- // Analog parameter : Optical output power oa100bdlabelOptOutPower DisplayString (SIZE (0..80)), oa100bduomOptOutPower DisplayString (SIZE (0..80)), oa100bdmajorHighOptOutPower Float, oa100bdmajorLowOptOutPower Float, oa100bdminorHighOptOutPower Float, oa100bdminorLowOptOutPower Float, oa100bdcurrentValueOptOutPower Float, oa100bdstateFlagOptOutPower INTEGER, oa100bdminValueOptOutPower Float, oa100bdmaxValueOptOutPower Float, oa100bdalarmStateOptOutPower INTEGER, -- // Analog parameter : Main TEC temperature oa100bdlabelMainTECTemp DisplayString (SIZE (0..80)), oa100bduomMainTECTemp DisplayString (SIZE (0..80)), oa100bdmajorHighMainTECTemp Float, oa100bdmajorLowMainTECTemp Float, oa100bdminorHighMainTECTemp Float, oa100bdminorLowMainTECTemp Float, oa100bdcurrentValueMainTECTemp Float, oa100bdstateFlagMainTECTemp INTEGER, oa100bdminValueMainTECTemp Float, oa100bdmaxValueMainTECTemp Float, oa100bdalarmStateMainTECTemp INTEGER, -- // Analog parameter : Main LASER power oa100bdlabelMainLaserPower DisplayString (SIZE (0..80)), oa100bduomMainLaserPower DisplayString (SIZE (0..80)), oa100bdmajorHighMainLaserPower Float, oa100bdmajorLowMainLaserPower Float, oa100bdminorHighMainLaserPower Float, oa100bdminorLowMainLaserPower Float, oa100bdcurrentValueMainLaserPower Float, oa100bdstateFlagMainLaserPower INTEGER, oa100bdminValueMainLaserPower Float, oa100bdmaxValueMainLaserPower Float, oa100bdalarmStateMainLaserPower INTEGER, -- // Analog parameter : Aux TEC temperature oa100bdlabelAuxTECTemp DisplayString (SIZE (0..80)), oa100bduomAuxTECTemp DisplayString (SIZE (0..80)), oa100bdmajorHighAuxTECTemp Float, oa100bdmajorLowAuxTECTemp Float, oa100bdminorHighAuxTECTemp Float, oa100bdminorLowAuxTECTemp Float, oa100bdcurrentValueAuxTECTemp Float, oa100bdstateFlagAuxTECTemp INTEGER, oa100bdminValueAuxTECTemp Float, oa100bdmaxValueAuxTECTemp Float, oa100bdalarmStateAuxTECTemp INTEGER, -- // Analog parameter : Aux LASER power oa100bdlabelAuxLaserPower DisplayString (SIZE (0..80)), oa100bduomAuxLaserPower DisplayString (SIZE (0..80)), oa100bdmajorHighAuxLaserPower Float, oa100bdmajorLowAuxLaserPower Float, oa100bdminorHighAuxLaserPower Float, oa100bdminorLowAuxLaserPower Float, oa100bdcurrentValueAuxLaserPower Float, oa100bdstateFlagAuxLaserPower INTEGER, oa100bdminValueAuxLaserPower Float, oa100bdmaxValueAuxLaserPower Float, oa100bdalarmStateAuxLaserPower INTEGER, -- // Analog parameter : Fan current oa100bdlabelFanCurrent DisplayString (SIZE (0..80)), oa100bduomFanCurrent DisplayString (SIZE (0..80)), oa100bdmajorHighFanCurrent Float, oa100bdmajorLowFanCurrent Float, oa100bdminorHighFanCurrent Float, oa100bdminorLowFanCurrent Float, oa100bdcurrentValueFanCurrent Float, oa100bdstateFlagFanCurrent INTEGER, oa100bdminValueFanCurrent Float, oa100bdmaxValueFanCurrent Float, oa100bdalarmStateFanCurrent INTEGER, -- // Analog parameter : Output power setting oa100bdlabelOPSetting DisplayString (SIZE (0..80)), oa100bduomOPSetting DisplayString (SIZE (0..80)), oa100bdmajorHighOPSetting Float, oa100bdmajorLowOPSetting Float, oa100bdminorHighOPSetting Float, oa100bdminorLowOPSetting Float, oa100bdcurrentValueOPSetting Float, oa100bdstateFlagOPSetting INTEGER, oa100bdminValueOPSetting Float, oa100bdmaxValueOPSetting Float, oa100bdalarmStateOPSetting INTEGER, -- // Analog parameter : Laser power setting oa100bdlabelLPSetting DisplayString (SIZE (0..80)), oa100bduomLPSetting DisplayString (SIZE (0..80)), oa100bdmajorHighLPSetting Float, oa100bdmajorLowLPSetting Float, oa100bdminorHighLPSetting Float, oa100bdminorLowLPSetting Float, oa100bdcurrentValueLPSetting Float, oa100bdstateFlagLPSetting INTEGER, oa100bdminValueLPSetting Float, oa100bdmaxValueLPSetting Float, oa100bdalarmStateLPSetting INTEGER, -- // Analog parameter : Constant gain setting oa100bdlabelCGSetting DisplayString (SIZE (0..80)), oa100bduomCGSetting DisplayString (SIZE (0..80)), oa100bdmajorHighCGSetting Float, oa100bdmajorLowCGSetting Float, oa100bdminorHighCGSetting Float, oa100bdminorLowCGSetting Float, oa100bdcurrentValueCGSetting Float, oa100bdstateFlagCGSetting INTEGER, oa100bdminValueCGSetting Float, oa100bdmaxValueCGSetting Float, oa100bdalarmStateCGSetting INTEGER, -- // Analog parameter : optical input threshold oa100bdlabelOptThreshold DisplayString (SIZE (0..80)), oa100bduomOptThreshold DisplayString (SIZE (0..80)), oa100bdmajorHighOptThreshold Float, oa100bdmajorLowOptThreshold Float, oa100bdminorHighOptThreshold Float, oa100bdminorLowOptThreshold Float, oa100bdcurrentValueOptThreshold Float, oa100bdstateFlagOptThreshold INTEGER, oa100bdminValueOptThreshold Float, oa100bdmaxValueOptThreshold Float, oa100bdalarmStateOptThreshold INTEGER } -- **************** Digital Parameters *********************** -- // Section: Digital parameters Gx2OA100BDDigitalEntry ::= SEQUENCE { gx2OA100BDDigitalTableIndex INTEGER, -- // Digital parameter : Mode setting oa100bdlabelModeSetting DisplayString (SIZE (0..80)), oa100bdvalueModeSetting INTEGER, oa100bdenumModeSetting DisplayString (SIZE (0..80)), oa100bdstateFlagModeSetting INTEGER, -- // Digital parameter : Module state oa100bdlabelModuleState DisplayString (SIZE (0..80)), oa100bdvalueModuleState INTEGER, oa100bdenumModuleState DisplayString (SIZE (0..80)), oa100bdstateFlagModuleState INTEGER, -- // Digital parameter : Factory default oa100bdlabelFactoryDefault DisplayString (SIZE (0..80)), oa100bdvalueFactoryDefault INTEGER, oa100bdenumFactoryDefault DisplayString (SIZE (0..80)), oa100bdstateFlagFactoryDefault INTEGER } -- **************** Status Parameters ************************************ -- // Section: Status parameters Gx2OA100BDStatusEntry ::= SEQUENCE { gx2OA100BDStatusTableIndex INTEGER, -- // Status parameter : boot oa100bdlabelBoot DisplayString (SIZE (0..80)), oa100bdvalueBoot INTEGER, oa100bdstateflagBoot INTEGER, -- // Status parameter : flash oa100bdlabelFlash DisplayString (SIZE (0..80)), oa100bdvalueFlash INTEGER, oa100bdstateflagFlash INTEGER, -- // Status parameter : Factory data crc oa100bdlabelFactoryDataCRC DisplayString (SIZE (0..80)), oa100bdvalueFactoryDataCRC INTEGER, oa100bdstateflagFactoryDataCRC INTEGER, -- // Status parameter : Alarm data crc oa100bdlabelAlarmDataCRC DisplayString (SIZE (0..80)), oa100bdvalueAlarmDataCRC INTEGER, oa100bdstateflagAlarmDataCRC INTEGER, -- // Status parameter : Calibration data crc oa100bdlabelCalibrationDataCRC DisplayString (SIZE (0..80)), oa100bdvalueCalibrationDataCRC INTEGER, oa100bdstateflagCalibrationDataCRC INTEGER, -- // Status parameter : optical power shutdown oa100bdlabelOptInShutdown DisplayString (SIZE (0..80)), oa100bdvalueOptInShutdown INTEGER, oa100bdstateflagOptInShutdown INTEGER, -- // Status parameter : Main TEC temp shutdown oa100bdlabelMainTECTempShutdown DisplayString (SIZE (0..80)), oa100bdvalueMainTECTempShutdown INTEGER, oa100bdstateflagMainTECTempShutdown INTEGER, -- // Status parameter : Aux TEC temp shutdown oa100bdlabelAuxTECTempShutdown DisplayString (SIZE (0..80)), oa100bdvalueAuxTECTempShutdown INTEGER, oa100bdstateflagAuxTECTempShutdown INTEGER, -- // Status parameter : power fail oa100bdlabelPowerFail DisplayString (SIZE (0..80)), oa100bdvaluePowerFail INTEGER, oa100bdstateflagPowerFail INTEGER, -- // Status parameter : Key switch oa100bdlabelKeySwitch DisplayString (SIZE (0..80)), oa100bdvalueKeySwitch INTEGER, oa100bdstateflagKeySwitch INTEGER, -- // Status parameter : Main laser current shutdown oa100bdlabelMainLaserCurrShutdown DisplayString (SIZE (0..80)), oa100bdvalueMainLaserCurrShutdown INTEGER, oa100bdstateflagMainLaserCurrShutdown INTEGER, -- // Status parameter : Aux laser current shutdown oa100bdlabelAuxLaserCurrShutdown DisplayString (SIZE (0..80)), oa100bdvalueAuxLaserCurrShutdown INTEGER, oa100bdstateflagAuxLaserCurrShutdown INTEGER, -- // Status parameter : Main laser power shutdown oa100bdlabelMainLaserPowShutdown DisplayString (SIZE (0..80)), oa100bdvalueMainLaserPowShutdown INTEGER, oa100bdstateflagMainLaserPowShutdown INTEGER, -- // Status parameter : Aux laser power shutdown oa100bdlabelAuxLaserPowShutdown DisplayString (SIZE (0..80)), oa100bdvalueAuxLaserPowShutdown INTEGER, oa100bdstateflagAuxLaserPowShutdown INTEGER, -- // Status parameter : ADC status oa100bdlabelADCStatus DisplayString (SIZE (0..80)), oa100bdvalueADCStatus INTEGER, oa100bdstateflagADCStatus INTEGER, -- // Status parameter : Constant gain oa100bdlabelConstGainStatus DisplayString (SIZE (0..80)), oa100bdvalueConstGainStatus INTEGER, oa100bdstateflagConstGainStatus INTEGER, -- // Status parameter : Hardware Error oa100bdlabelHardwareErrorStatus DisplayString (SIZE (0..80)), oa100bdvalueHardwareErrorStatus INTEGER, oa100bdstateflagHardwareErrorStatus INTEGER, -- // Status parameter : standby oa100bdlabelStandbyStatus DisplayString (SIZE (0..80)), oa100bdvalueStandbyStatus INTEGER, oa100bdstateflagStandbyStatus INTEGER } -- **************** Factory Parameters ************************************* -- // Section: Factory parameters Gx2OA100BDFactoryEntry ::= SEQUENCE { gx2OA100BDFactoryTableIndex INTEGER, oa100bdbootControlByte INTEGER, oa100bdbootStatusByte INTEGER, oa100bdbank0CRC INTEGER, oa100bdbank1CRC INTEGER, oa100bdprgEEPROMByte INTEGER, oa100bdfactoryCRC INTEGER, oa100bdcalculateCRC INTEGER, oa100bdhourMeter INTEGER, oa100bdflashPrgCntA INTEGER, oa100bdflashPrgCntB INTEGER, oa100bdfwRev0 DisplayString (SIZE (0..80)), oa100bdfwRev1 DisplayString (SIZE (0..80)) } -- // Section: Analog parameter detail gx2OA100BDAnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2OA100BDAnalogEntry 1} -- // New Parameter - Module Temperature oa100bdlabelModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2OA100BDAnalogEntry 2} oa100bduomModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2OA100BDAnalogEntry 3} oa100bdmajorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 4} oa100bdmajorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 5} oa100bdminorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 6} oa100bdminorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 7} oa100bdcurrentValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 8} oa100bdstateFlagModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDAnalogEntry 9} oa100bdminValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 10} oa100bdmaxValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 11} oa100bdalarmStateModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2OA100BDAnalogEntry 12} -- // New Parameter - Optical Input Power oa100bdlabelOptInPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Input Power Analog parameter." ::= { gx2OA100BDAnalogEntry 13} oa100bduomOptInPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Input Power Analog parameter." ::= { gx2OA100BDAnalogEntry 14} oa100bdmajorHighOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 15} oa100bdmajorLowOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 16} oa100bdminorHighOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 17} oa100bdminorLowOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 18} oa100bdcurrentValueOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 19} oa100bdstateFlagOptInPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDAnalogEntry 20} oa100bdminValueOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 21} oa100bdmaxValueOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 22} oa100bdalarmStateOptInPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Input Power Analog parameter." ::= { gx2OA100BDAnalogEntry 23} -- // New Parameter - Optical Output Power oa100bdlabelOptOutPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Output Power Analog parameter." ::= { gx2OA100BDAnalogEntry 24} oa100bduomOptOutPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Output Power Analog parameter." ::= { gx2OA100BDAnalogEntry 25} oa100bdmajorHighOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 26} oa100bdmajorLowOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 27} oa100bdminorHighOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 28} oa100bdminorLowOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 29} oa100bdcurrentValueOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 30} oa100bdstateFlagOptOutPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDAnalogEntry 31} oa100bdminValueOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 32} oa100bdmaxValueOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 33} oa100bdalarmStateOptOutPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Output Power Analog parameter." ::= { gx2OA100BDAnalogEntry 34} -- // New Parameter - Main TEC temperature oa100bdlabelMainTECTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Temperature Analog parameter." ::= { gx2OA100BDAnalogEntry 35} oa100bduomMainTECTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the TEC Temperature Analog parameter." ::= { gx2OA100BDAnalogEntry 36} oa100bdmajorHighMainTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 37} oa100bdmajorLowMainTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 38} oa100bdminorHighMainTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 39} oa100bdminorLowMainTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 40} oa100bdcurrentValueMainTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 41} oa100bdstateFlagMainTECTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDAnalogEntry 42} oa100bdminValueMainTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 43} oa100bdmaxValueMainTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 44} oa100bdalarmStateMainTECTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the TEC Temperature Analog parameter." ::= { gx2OA100BDAnalogEntry 45} -- // New Parameter - Main Laser Power oa100bdlabelMainLaserPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Main Laser Power Analog parameter." ::= { gx2OA100BDAnalogEntry 46} oa100bduomMainLaserPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Main Laser Power Analog parameter." ::= { gx2OA100BDAnalogEntry 47} oa100bdmajorHighMainLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 48} oa100bdmajorLowMainLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 49} oa100bdminorHighMainLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 50} oa100bdminorLowMainLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 51} oa100bdcurrentValueMainLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 52} oa100bdstateFlagMainLaserPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Main Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDAnalogEntry 53} oa100bdminValueMainLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 54} oa100bdmaxValueMainLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 55} oa100bdalarmStateMainLaserPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Main Laser Power Analog parameter." ::= { gx2OA100BDAnalogEntry 56} -- // New Parameter - Aux TEC temperature oa100bdlabelAuxTECTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Temperature Analog parameter." ::= { gx2OA100BDAnalogEntry 57} oa100bduomAuxTECTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the TEC Temperature Analog parameter." ::= { gx2OA100BDAnalogEntry 58} oa100bdmajorHighAuxTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 59} oa100bdmajorLowAuxTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 60} oa100bdminorHighAuxTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 61} oa100bdminorLowAuxTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 62} oa100bdcurrentValueAuxTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 63} oa100bdstateFlagAuxTECTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDAnalogEntry 64} oa100bdminValueAuxTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 65} oa100bdmaxValueAuxTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 66} oa100bdalarmStateAuxTECTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the TEC Temperature Analog parameter." ::= { gx2OA100BDAnalogEntry 67} -- // New Parameter - Aux Laser Power oa100bdlabelAuxLaserPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Aux Laser Power Analog parameter." ::= { gx2OA100BDAnalogEntry 68} oa100bduomAuxLaserPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Aux Laser Power Analog parameter." ::= { gx2OA100BDAnalogEntry 69} oa100bdmajorHighAuxLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 70} oa100bdmajorLowAuxLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 71} oa100bdminorHighAuxLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 72} oa100bdminorLowAuxLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 73} oa100bdcurrentValueAuxLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 74} oa100bdstateFlagAuxLaserPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Aux Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDAnalogEntry 75} oa100bdminValueAuxLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 76} oa100bdmaxValueAuxLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 77} oa100bdalarmStateAuxLaserPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Aux Laser Power Analog parameter." ::= { gx2OA100BDAnalogEntry 78} -- // New Parameter - Fan Current oa100bdlabelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2OA100BDAnalogEntry 79} oa100bduomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter." ::= { gx2OA100BDAnalogEntry 80} oa100bdmajorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 81} oa100bdmajorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 82} oa100bdminorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 83} oa100bdminorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 84} oa100bdcurrentValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 85} oa100bdstateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDAnalogEntry 86} oa100bdminValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 87} oa100bdmaxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 88} oa100bdalarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2OA100BDAnalogEntry 89} -- // New Parameter - Output Power Setting oa100bdlabelOPSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Output Power Setting Analog parameter." ::= { gx2OA100BDAnalogEntry 90} oa100bduomOPSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v Current Analog parameter." ::= { gx2OA100BDAnalogEntry 91} oa100bdmajorHighOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 92} oa100bdmajorLowOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 93} oa100bdminorHighOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 94} oa100bdminorLowOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 95} oa100bdcurrentValueOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 96} oa100bdstateFlagOPSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Output Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDAnalogEntry 97} oa100bdminValueOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 98} oa100bdmaxValueOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 99} oa100bdalarmStateOPSetting OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Output Power Setting Analog parameter." ::= { gx2OA100BDAnalogEntry 100} -- // New Parameter - Laser Power Setting oa100bdlabelLPSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Power Setting Analog parameter." ::= { gx2OA100BDAnalogEntry 101} oa100bduomLPSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Power Setting Analog parameter." ::= { gx2OA100BDAnalogEntry 102} oa100bdmajorHighLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 103} oa100bdmajorLowLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 104} oa100bdminorHighLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 105} oa100bdminorLowLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 106} oa100bdcurrentValueLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 107} oa100bdstateFlagLPSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDAnalogEntry 108} oa100bdminValueLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 109} oa100bdmaxValueLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 110} oa100bdalarmStateLPSetting OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Power Setting Analog parameter." ::= { gx2OA100BDAnalogEntry 111} -- // New Parameter - Constant Gain Setting oa100bdlabelCGSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Constant Gain Setting Analog parameter." ::= { gx2OA100BDAnalogEntry 112} oa100bduomCGSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Constant Gain Setting Analog parameter." ::= { gx2OA100BDAnalogEntry 113} oa100bdmajorHighCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 114} oa100bdmajorLowCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 115} oa100bdminorHighCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 116} oa100bdminorLowCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 117} oa100bdcurrentValueCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 118} oa100bdstateFlagCGSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Constant Gain Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDAnalogEntry 119} oa100bdminValueCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 120} oa100bdmaxValueCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 121} oa100bdalarmStateCGSetting OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Constant Gain Setting Analog parameter." ::= { gx2OA100BDAnalogEntry 122} -- // New Parameter - Optical Input Threshold oa100bdlabelOptThreshold OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Input Threshold Analog parameter." ::= { gx2OA100BDAnalogEntry 123} oa100bduomOptThreshold OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Input Threshold Analog parameter." ::= { gx2OA100BDAnalogEntry 124} oa100bdmajorHighOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 125} oa100bdmajorLowOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 126} oa100bdminorHighOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 127} oa100bdminorLowOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 128} oa100bdcurrentValueOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 129} oa100bdstateFlagOptThreshold OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Input Threshold Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDAnalogEntry 130} oa100bdminValueOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 131} oa100bdmaxValueOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2OA100BDAnalogEntry 132} oa100bdalarmStateOptThreshold OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Input Threshold Analog parameter." ::= { gx2OA100BDAnalogEntry 133} -- // Section: Digital parameter detail gx2OA100BDDigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2OA100BDDigitalEntry 1} -- // New parameter - Mode Setting oa100bdlabelModeSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the OA100BD's Mode Digital parameter." ::= { gx2OA100BDDigitalEntry 2} oa100bdenumModeSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0." ::= { gx2OA100BDDigitalEntry 3} oa100bdvalueModeSetting OBJECT-TYPE SYNTAX INTEGER { power-out-preset(1), power-out-set(2), laser-power-preset(3), laser-power-set(4), constant-gain-preset(5), constant-gain-set(6), invalid-mode(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is an integer value from 0 to 5 representing the operation mode of the module." ::= { gx2OA100BDDigitalEntry 4} oa100bdstateFlagModeSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDDigitalEntry 5} -- // New parameter - Module State oa100bdlabelModuleState OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module State Digital parameter." ::= { gx2OA100BDDigitalEntry 6} oa100bdenumModuleState OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2OA100BDDigitalEntry 7} oa100bdvalueModuleState OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2OA100BDDigitalEntry 8} oa100bdstateFlagModuleState OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDDigitalEntry 9} -- // New parameter - Factory Default oa100bdlabelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2OA100BDDigitalEntry 10} oa100bdenumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2OA100BDDigitalEntry 11} oa100bdvalueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2OA100BDDigitalEntry 12} oa100bdstateFlagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDDigitalEntry 13} -- // Section: Status parameter detail gx2OA100BDStatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2OA100BDStatusEntry 1} -- // New Parameter - Boot status oa100bdlabelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2OA100BDStatusEntry 2} oa100bdvalueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 3} oa100bdstateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 4} -- // New Parameter - Flash status oa100bdlabelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2OA100BDStatusEntry 5} oa100bdvalueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 6} oa100bdstateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 7} -- // New Parameter - Factory Data CRC status oa100bdlabelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2OA100BDStatusEntry 8} oa100bdvalueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 9} oa100bdstateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 10} -- // New Parameter - Alarm Data CRC status oa100bdlabelAlarmDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data CRC Status parameter." ::= { gx2OA100BDStatusEntry 11} oa100bdvalueAlarmDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 12} oa100bdstateflagAlarmDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 13} -- // New Parameter - Calibration Data CRC status oa100bdlabelCalibrationDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Calibration Data CRC Status parameter." ::= { gx2OA100BDStatusEntry 14} oa100bdvalueCalibrationDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 15} oa100bdstateflagCalibrationDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 16} -- // New Parameter - Optical power in shutdown status oa100bdlabelOptInShutdown OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Input Power Shutdown Status parameter." ::= { gx2OA100BDStatusEntry 17} oa100bdvalueOptInShutdown OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 18} oa100bdstateflagOptInShutdown OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 19} -- // New Parameter - Main TEC temperature in shutdown status oa100bdlabelMainTECTempShutdown OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Main TEC Temperature Shutdown Status parameter." ::= { gx2OA100BDStatusEntry 20} oa100bdvalueMainTECTempShutdown OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 21} oa100bdstateflagMainTECTempShutdown OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 22} -- // New Parameter - Aux TEC temperature in shutdown status oa100bdlabelAuxTECTempShutdown OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Aux TEC Temperature Shutdown Status parameter." ::= { gx2OA100BDStatusEntry 23} oa100bdvalueAuxTECTempShutdown OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 24} oa100bdstateflagAuxTECTempShutdown OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 25} -- // New Parameter - Power Supply Failure status oa100bdlabelPowerFail OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Power Supply Fail Status parameter." ::= { gx2OA100BDStatusEntry 26} oa100bdvaluePowerFail OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 27} oa100bdstateflagPowerFail OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 28} -- // New Parameter - Key Switch status oa100bdlabelKeySwitch OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Key Switch Setting Status parameter." ::= { gx2OA100BDStatusEntry 29} oa100bdvalueKeySwitch OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 30} oa100bdstateflagKeySwitch OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 31} -- // New Parameter - Main Laser Current Shutdown status oa100bdlabelMainLaserCurrShutdown OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Main Laser Current Shutdown Status parameter." ::= { gx2OA100BDStatusEntry 32} oa100bdvalueMainLaserCurrShutdown OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 33} oa100bdstateflagMainLaserCurrShutdown OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 34} -- // New Parameter - Aux Laser Current Shutdown status oa100bdlabelAuxLaserCurrShutdown OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the AuxLaser Current Shutdown Status parameter." ::= { gx2OA100BDStatusEntry 35} oa100bdvalueAuxLaserCurrShutdown OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 36} oa100bdstateflagAuxLaserCurrShutdown OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 37} -- // New Parameter - Main Laser Power Shutdown oa100bdlabelMainLaserPowShutdown OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Main Laser Power Shutdown Status parameter." ::= { gx2OA100BDStatusEntry 38} oa100bdvalueMainLaserPowShutdown OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 39} oa100bdstateflagMainLaserPowShutdown OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 40} -- // New Parameter - Aux Laser Power Shutdown oa100bdlabelAuxLaserPowShutdown OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Aux Laser Power Shutdown Status parameter." ::= { gx2OA100BDStatusEntry 41} oa100bdvalueAuxLaserPowShutdown OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 42} oa100bdstateflagAuxLaserPowShutdown OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 43} -- // New Parameter - ADC status oa100bdlabelADCStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the ADC Operation Status parameter." ::= { gx2OA100BDStatusEntry 44} oa100bdvalueADCStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 45} oa100bdstateflagADCStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 46} -- // New Parameter - Constant Gain status oa100bdlabelConstGainStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Constant Gain Status parameter." ::= { gx2OA100BDStatusEntry 47} oa100bdvalueConstGainStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 48} oa100bdstateflagConstGainStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 49} -- // New Parameter - Hardware Error status oa100bdlabelHardwareErrorStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Hardware Error Status parameter." ::= { gx2OA100BDStatusEntry 50} oa100bdvalueHardwareErrorStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 51} oa100bdstateflagHardwareErrorStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 52} -- // New Parameter - Standby status oa100bdlabelStandbyStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Standby Status parameter." ::= { gx2OA100BDStatusEntry 53} oa100bdvalueStandbyStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2OA100BDStatusEntry 54} oa100bdstateflagStandbyStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2OA100BDStatusEntry 55} -- // Section: Factory Data parameter detail gx2OA100BDFactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2OA100BDFactoryEntry 1} -- // New Parameter - boot control byte oa100bdbootControlByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from. Boot Control Byte bit definition as follows : bit 0 : boot bit (0=boot from bank 0, 1=boot from bank 1) bit 1 : bank 0 status (0=bank is blank/bad, 1=bank is OK) bit 2 : bank 1 status (0=bank is blank/bad, 1=bank is OK) bits 3-7 : not used" ::= { gx2OA100BDFactoryEntry 2} -- // New Parameter - boot status byte oa100bdbootStatusByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot Boot Status Byte bit definitions as follows: bit 0 : bank 0 status (0=bank is OK or not used, 1=bank failed boot) bit 1 : bank 1 status (0=bank is OK or not used, 1=bank failed boot) bit 2 : active bank (0=bank 0 active, 1=bank 1 active) bits 3-7: not used" ::= { gx2OA100BDFactoryEntry 3} -- // New Parameter - bank 0 CRC oa100bdbank0CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0. The value is best displayed in Hex format" ::= { gx2OA100BDFactoryEntry 4} -- // New Parameter - bank 1 CRC oa100bdbank1CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1. The value is best displayed in Hex format" ::= { gx2OA100BDFactoryEntry 5} -- // New Parameter - programmed EEPROM byte oa100bdprgEEPROMByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed programmed EEPROM byte definitions as follows: 0xBB = EEPROM is programmed 0xDB = EEPROM is being restored to factory defaults 0xFF = EEPROM is blank any other values are assumed to be blank EEPROM" ::= { gx2OA100BDFactoryEntry 6} -- // New Parameter - factory CRC oa100bdfactoryCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data. The value is best displayed in Hex format" ::= { gx2OA100BDFactoryEntry 7} -- // New Parameter - calculate CRC command oa100bdcalculateCRC OBJECT-TYPE SYNTAX INTEGER { factory(1), calibration(2), alarmdata(3) } ACCESS read-only STATUS obsolete DESCRIPTION "This object indicates which of the Emnums will have the CRC calculated. Calculate CRC command defintions as follows : 0x00 : recalculate factory data CRC 0x01 : recalcualte calibration table CRC 0x02 : recalculate alarm data CRC other values not defined" ::= { gx2OA100BDFactoryEntry 8} -- // New Parameter - hour meter oa100bdhourMeter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2OA100BDFactoryEntry 9} -- // New Parameter - flash program counter A oa100bdflashPrgCntA OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times the flash has been programmed on side A." ::= { gx2OA100BDFactoryEntry 10} -- // New Parameter - flash program counter B oa100bdflashPrgCntB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times the flash has been programmed on side B." ::= { gx2OA100BDFactoryEntry 11} -- // New Parameter - Firmware Rev Bank 0 oa100bdfwRev0 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Revision of the firmware stores in bank 0. This value should be displayed as two ascii characters." ::= { gx2OA100BDFactoryEntry 12} -- // New Parameter - Firmware Rev Bank 1 oa100bdfwRev1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Revision of the firmware stores in bank 1. This value should be displayed as two ascii characters." ::= { gx2OA100BDFactoryEntry 13} -- // Section: Factory Data parameter detail -- **************** Hold Time Parameters ************************************* Gx2OA100BDHoldTimeEntry ::= SEQUENCE { gx2OA100BDHoldTimeTableIndex INTEGER, gx2OA100BDHoldTimeSpecIndex INTEGER, gx2OA100BDHoldTimeData INTEGER } gx2OA100BDHoldTimeTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the index of the data object." ::= { gx2OA100BDHoldTimeEntry 1} gx2OA100BDHoldTimeSpecIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the index of the alarm object to be modified." ::= { gx2OA100BDHoldTimeEntry 2} gx2OA100BDHoldTimeData OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds." ::= { gx2OA100BDHoldTimeEntry 3} -- // Section: Trap Definitions -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** -- ************************************************************************** -- OA100BD Module traps -- ************************************************************************** -- // Trap 1 : integer congif change trapOA100BDConfigChangeInteger TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 -- // Trap 2 : string config change trapOA100BDConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 -- // Trap 3 : Module temperature alarm trapOA100BDModuleTemperatureAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Module's Temperature goes out of range." ::= 3 -- // Trap 4 : optical input power alarm trapOA100BDOpticalInPowerAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the input Optical Input Power parameter goes out of range." ::= 4 -- // Trap 5 : optical output power alarm trapOA100BDOpticalOutPowerAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the input Optical Output Power parameter goes out of range." ::= 5 -- // Trap 6 : Main TEC temperature alarm trapOA100BDMainTECTemperatureAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Main TEC Temperature goes out of range." ::= 6 -- // Trap 7 : Main Laser Power alarm trapOA100BDMainLaserPowerAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Main Laser Power goes out of range." ::= 7 -- // Trap 8 : Aux TEC temperature alarm trapOA100BDAuxTECTemperatureAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Aux TEC Temperature goes out of range." ::= 8 -- // Trap 9 : Aux Laser Power alarm trapOA100BDAuxLaserPowerAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Aux Laser Power goes out of range." ::= 9 -- // Trap 10 : Fan Current alarm trapOA100BDFanCurrentAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Module's Fan Currrent parameter goes out of range." ::= 10 -- // Trap 11 : Reset to factory default trapOA100BDResetFacDefault TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B resets to factory defaults" ::= 11 -- // Trap 12 : Standby mode trapOA100BDStandbyMode TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B is in Standby Mode." ::= 12 -- // Trap 13 : Optical input shutdown trapOA100BDOptInShutdown TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B is in Optical Input Shutdown." ::= 13 -- // Trap 14 : Main TEC temperature shutdown trapOA100BDMainTECTempShutdown TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B is in Main TEC Temperature Shutdown." ::= 14 -- // Trap 15 : Aux TEC temperature shutdown trapOA100BDAuxTECTempShutdown TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B is in Aux TEC Temperature Shutdown." ::= 15 -- // Trap 16 : Key switch trapOA100BDKeySwitch TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Key Switch disables the OA100B." ::= 16 -- // Trap 17 : Power Fail trapOA100BDPowerFail TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when there is an OA100B Power Supply Failure." ::= 17 -- // Trap 18 : Main Laser Current shutdown trapOA100BDMainLasCurrShutdown TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B is in Main Laser Current Shutdown." ::= 18 -- // Trap 19 : Aux Laser Current shutdown trapOA100BDAuxLasCurrShutdown TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B is in Aux Laser Current Shutdown." ::= 19 -- // Trap 20 : Main Laser Power shutdown trapOA100BDMainLasPowerShutdown TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B is in Main Laser Power Shutdown." ::= 20 -- // Trap 21 : Aux Laser Power shutdown trapOA100BDAuxLasPowerShutdown TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B is in Aux Laser Power Shutdown." ::= 21 -- // Trap 22 : Invalid mode trapOA100BDInvalidMode TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B is in an invalid mode." ::= 22 -- // Trap 23 : Flash alarm trapOA100BDFlashAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Module's boot or flash programming sequence has detected a Flash error." ::= 23 -- // Trap 24 : Boot 0 alarm trapOA100BDBoot0Alarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Module's Bank 0 Boot sequence has detected an error." ::= 24 -- // Trap 25 : Boot 1 alarm trapOA100BDBoot1Alarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Module's Bank 1 Boot sequence has detected an error." ::= 25 -- // Trap 26 : Alarm data CRC alarm trapOA100BDAlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Module detects an error calculating the alarm limit CRC." ::= 26 -- // Trap 27 : Factory Data CRC alarm trapOA100BDFactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Module detects an error calculating the Factory data CRC." ::= 27 -- // Trap 28 : Calibration Data CRC alarm trapOA100BDCalDataCRCAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Module detects an error calculating the Calibration data CRC." ::= 28 -- // Trap 29 : Calibration Floating Point Number alarm trapOA100BDFacCalFloatAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Module detects factory calibration float data alarm." ::= 29 -- // Trap 30 : Optical Input Threshold alarm trapOA100BDOptInThreshAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Module Optical Input drops below the user set threshold." ::= 30 -- // Trap 31 : Gain Error alarm trapOA100BDGainErrorAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OA100B Module can not produce the desired user set gain in Constant Gain Set Mode." ::= 31 -- // Trap 32 : Hardware Error alarm trapOA100BDHardwareErrorAlarm TRAP-TYPE ENTERPRISE gx2OA100BD VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when any of the OA100BD Module's TEC,Laser, +12V, or +3.7V current parameters go out of range." ::= 32 END -- // Section: End of file