OMNI-gx2dualdrr2x-MIB :: trapdualdrr12VCurrentAlarm

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2dualdrr2x-MIB › trapdualdrr12VCurrentAlarm

trapdualdrr12VCurrentAlarm

Module: OMNI-gx2dualdrr2x-MIB

OID (symbolic): OMNI-gx2dualdrr2x-MIB::trapdualdrr12VCurrentAlarm

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.35.0.3

Node type: NOTIFICATION-TYPE

Description: This trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' OMNI-gx2dualdrr2x-MIB::trapdualdrr12VCurrentAlarm
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.1166.6.1.2.35.0.3

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:50006->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (279744854) 32 days, 9:04:08.54
  SNMPv2-MIB::snmpTrapOID.0 = OID: OMNI-gx2dualdrr2x-MIB::trapdualdrr12VCurrentAlarm

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (gx2dualdrr2x dual optical receiver module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2dualdrr2x-MIB::trapdualdrr12VCurrentAlarm OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (gx2dualdrr2x dual optical receiver module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.35gx2DualDrr2xGX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.35.0.3trapdualdrr12VCurrentAlarmOMNI-gx2dualdrr2x-MIB