All MIBs › OMNI-gx2Rx200BX4-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 RX200BX4 200 MHz quad-port optical receiver card in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2Rx200BX4-MIB?
OMNI-gx2Rx200BX4-MIB is a vendor-specific SNMP module from Cisco/Scientific-Atlanta covering the GX2 RX200BX4, a 200 MHz quad-port optical receiver card used in HFC optical node deployments. It provides hardware inventory and per-port status information for the receiver card, focused on optical/RF signal quality rather than software configuration. Its main monitoring role is hardware fault detection: identifying card presence, receive signal loss, and out-of-spec optical levels that signal a degrading or failed optical receiver port. Like related GX2 card MIBs, it presumably relies on a shared GX2 platform/chassis MIB for common slot, card, and port indexing structures. It is used by cable operators managing HFC optical nodes in field cabinets through centralized SNMP network management systems. Engineers can download the OMNI-gx2Rx200BX4-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2Rx200BX4-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 RX200BX4 200 MHz quad-port optical receiver card)
Monitoring Examples
No sample objects were supplied for this module, so no specific table or object names can be cited. Consistent with sibling GX2 receiver card MIBs, monitoring would plausibly involve a per-port table of optical receive levels and card/port status flags indexed by slot number. An operator would poll such objects to catch a port reporting abnormally low optical input, which typically points to a damaged fiber run or a failing upstream transmitter. This description stays general because the source data did not include concrete identifiers.
What Can Be Monitored
- card presence/insertion status
- optical receive signal level
- port operational status
- RF output level
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Rx200BX4 | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapRx200BX4ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.29.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapRx200BX4ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.29.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapRx200BX4OpticalPower1Alarm | 1.3.6.1.4.1.1166.6.1.2.29.0.3 | This trap is issued when the Receiver's channel 1 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4OpticalPower2Alarm | 1.3.6.1.4.1.1166.6.1.2.29.0.4 | This trap is issued when the Receiver's channel 2 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4OpticalPower3Alarm | 1.3.6.1.4.1.1166.6.1.2.29.0.5 | This trap is issued when the Receiver's channel 3 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4OpticalPower4Alarm | 1.3.6.1.4.1.1166.6.1.2.29.0.6 | This trap is issued when the Receiver's channel 4 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4ModuleTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.7 | This trap is issued when the Rx200BX4 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4FanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.8 | This trap is issued when the Rx200BX4 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4Plus12CurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.9 | This trap is issued when the Rx200BX4 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4Boot0Alarm | 1.3.6.1.4.1.1166.6.1.2.29.0.10 | This trap is issued when the Rx200BX4 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4Boot1Alarm | 1.3.6.1.4.1.1166.6.1.2.29.0.11 | This trap is issued when the Rx200BX4 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.12 | This trap is issued when the Rx200BX4 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.13 | This trap is issued when the Rx200BX4 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.14 | This trap is issued when the Rx200BX4 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4CalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.15 | This trap is issued when the Rx200BX4 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4DefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.16 | This trap is issued when the Rx200BX4 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4Mode1Alarm | 1.3.6.1.4.1.1166.6.1.2.29.0.17 | This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4Mode2Alarm | 1.3.6.1.4.1.1166.6.1.2.29.0.18 | This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4Mode3Alarm | 1.3.6.1.4.1.1166.6.1.2.29.0.19 | This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4Mode4Alarm | 1.3.6.1.4.1.1166.6.1.2.29.0.20 | This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4Output1SwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.21 | This trap is issued when the Rx200BX4 Module's receiver 1 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4Output2SwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.22 | This trap is issued when the Rx200BX4 Module's receiver 2 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4Output3SwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.23 | This trap is issued when the Rx200BX4 Module's receiver 3 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4Output4SwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.24 | This trap is issued when the Rx200BX4 Module's receiver 4 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx200BX4RX1StatusAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.25 | This trap is issued when receiver 1 of the Rx200BX4 Module output is turned on or off. | ||
| NTF trapRx200BX4RX2StatusAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.26 | This trap is issued when receiver 2 of the Rx200BX4 Module output is turned on or off. | ||
| NTF trapRx200BX4RX3StatusAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.27 | This trap is issued when receiver 3 of the Rx200BX4 Module output is turned on or off. | ||
| NTF trapRx200BX4RX4StatusAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.28 | This trap is issued when receiver 4 of the Rx200BX4 Module output is turned on or off. | ||
| NTF trapRx200BX4BackupCableAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.29 | This trap is issued when the slave receiver loses connection to the master receiver. | ||
| NTF trapRx200BX4OptPwr1BadAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.30 | This trap is issued when the receiver 1 optical power level falls below the user set switching threshold. | ||
| NTF trapRx200BX4OptPwr2BadAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.31 | This trap is issued when the receiver 2 optical power level falls below the user set switching threshold. | ||
| NTF trapRx200BX4OptPwr3BadAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.32 | This trap is issued when the receiver 3 optical power level falls below the user set switching threshold. | ||
| NTF trapRx200BX4OptPwr4BadAlarm | 1.3.6.1.4.1.1166.6.1.2.29.0.33 | This trap is issued when the receiver 4 optical power level falls below the user set switching threshold. | ||
| gx2Rx200BX4Descriptor | 1.3.6.1.4.1.1166.6.1.2.29.1 | |||
| gx2Rx200BX4AnalogTable | 1.3.6.1.4.1.1166.6.1.2.29.2 | not-accessible | This table contains gx2Rx200BX4 specific parameters with nominal and current values. | |
| gx2Rx200BX4AnalogEntry | 1.3.6.1.4.1.1166.6.1.2.29.2.1 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Rx200BX4AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.29.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR rx4labelOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.29.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR rx4uomOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.29.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO rx4majorHighOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.29.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4majorLowOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.29.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorHighOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.29.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorLowOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.29.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4currentValueOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.29.2.1.8 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4stateFlagOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.29.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx4minValueOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.29.2.1.10 | Float | read-only | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4maxValueOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.29.2.1.11 | Float | read-only | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4alarmStateOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.29.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR rx4labelOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.29.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR rx4uomOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.29.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO rx4majorHighOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.29.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4majorLowOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.29.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorHighOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.29.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorLowOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.29.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4currentValueOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.29.2.1.19 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4stateFlagOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.29.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx4minValueOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.29.2.1.21 | Float | read-only | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4maxValueOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.29.2.1.22 | Float | read-only | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4alarmStateOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.29.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR rx4labelOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.29.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR rx4uomOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.29.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO rx4majorHighOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.29.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4majorLowOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.29.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorHighOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.29.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorLowOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.29.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4currentValueOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.29.2.1.30 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4stateFlagOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.29.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx4minValueOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.29.2.1.32 | Float | read-only | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4maxValueOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.29.2.1.33 | Float | read-only | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4alarmStateOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.29.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR rx4labelOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.29.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR rx4uomOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.29.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO rx4majorHighOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.29.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4majorLowOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.29.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorHighOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.29.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorLowOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.29.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4currentValueOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.29.2.1.41 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4stateFlagOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.29.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx4minValueOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.29.2.1.43 | Float | read-only | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4maxValueOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.29.2.1.44 | Float | read-only | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4alarmStateOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.29.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR rx4labelModTemp | 1.3.6.1.4.1.1166.6.1.2.29.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR rx4uomModTemp | 1.3.6.1.4.1.1166.6.1.2.29.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO rx4majorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.29.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4majorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.29.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.29.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.29.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4currentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.29.2.1.52 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4stateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.29.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx4minValueModTemp | 1.3.6.1.4.1.1166.6.1.2.29.2.1.54 | Float | read-only | The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4maxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.29.2.1.55 | Float | read-only | The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4alarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.29.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR rx4labelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.29.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR rx4uomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.29.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO rx4majorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.29.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4majorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.29.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.29.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.29.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4currentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.29.2.1.63 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4stateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.29.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx4minValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.29.2.1.65 | Float | read-only | The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4maxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.29.2.1.66 | Float | read-only | The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4alarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.29.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR rx4label12Volt | 1.3.6.1.4.1.1166.6.1.2.29.2.1.68 | DisplayString | read-only | The value of this object provides the label of the 12v Current Analog parameter. |
| STR rx4uom12Volt | 1.3.6.1.4.1.1166.6.1.2.29.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO rx4majorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.29.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4majorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.29.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.29.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4minorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.29.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4currentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.29.2.1.74 | Float | read-only | The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4stateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.29.2.1.75 | INTEGER | read-only | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx4minValue12Volt | 1.3.6.1.4.1.1166.6.1.2.29.2.1.76 | Float | read-only | The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx4maxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.29.2.1.77 | Float | read-only | The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx4alarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.29.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| gx2Rx200BX4DigitalTable | 1.3.6.1.4.1.1166.6.1.2.29.3 | not-accessible | This table contains gx2Rx200BX4 specific parameters with nominal and current values. | |
| gx2Rx200BX4DigitalEntry | 1.3.6.1.4.1.1166.6.1.2.29.3.2 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Rx200BX4DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.29.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR rx4labelModeOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.2 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Mode Digital parameter. |
| STR rx4enumModeOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueModeOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagModeOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelWavelengthOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter. |
| STR rx4enumWavelengthOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueWavelengthOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagWavelengthOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelAttnSettingOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter. |
| STR rx4enumAttnSettingOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueAttnSettingOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db |
| INT rx4stateFlagAttnSettingOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelSwModeSettingOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter. |
| STR rx4enumSwModeSettingOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueSwModeSettingOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagSwModeSettingOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelSwModeThresholdOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.18 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter. |
| STR rx4enumSwModeThresholdOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueSwModeThresholdOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.20 | INTEGER | read-write | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
| INT rx4stateFlagSwModeThresholdOne | 1.3.6.1.4.1.1166.6.1.2.29.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelModeTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.22 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Mode Digital parameter. |
| STR rx4enumModeTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueModeTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.24 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagModeTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelWavelengthTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.26 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter. |
| STR rx4enumWavelengthTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.27 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueWavelengthTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.28 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagWavelengthTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.29 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelAttnSettingTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.30 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter. |
| STR rx4enumAttnSettingTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.31 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueAttnSettingTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.32 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db |
| INT rx4stateFlagAttnSettingTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.33 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelSwModeSettingTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.34 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter. |
| STR rx4enumSwModeSettingTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.35 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueSwModeSettingTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.36 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagSwModeSettingTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.37 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelSwModeThresholdTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.38 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter. |
| STR rx4enumSwModeThresholdTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.39 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueSwModeThresholdTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.40 | INTEGER | read-write | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
| INT rx4stateFlagSwModeThresholdTwo | 1.3.6.1.4.1.1166.6.1.2.29.3.2.41 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelModeThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.42 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Mode Digital parameter. |
| STR rx4enumModeThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.43 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueModeThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.44 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagModeThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.45 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelWavelengthThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.46 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter. |
| STR rx4enumWavelengthThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.47 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueWavelengthThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.48 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagWavelengthThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.49 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelAttnSettingThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.50 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter. |
| STR rx4enumAttnSettingThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.51 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueAttnSettingThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.52 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db |
| INT rx4stateFlagAttnSettingThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.53 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelSwModeSettingThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.54 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter. |
| STR rx4enumSwModeSettingThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.55 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueSwModeSettingThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.56 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagSwModeSettingThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.57 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelSwModeThresholdThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.58 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter. |
| STR rx4enumSwModeThresholdThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.59 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueSwModeThresholdThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.60 | INTEGER | read-write | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
| INT rx4stateFlagSwModeThresholdThree | 1.3.6.1.4.1.1166.6.1.2.29.3.2.61 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelModeFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.62 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Mode Digital parameter. |
| STR rx4enumModeFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.63 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueModeFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.64 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagModeFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.65 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelWavelengthFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.66 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter. |
| STR rx4enumWavelengthFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.67 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueWavelengthFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.68 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagWavelengthFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.69 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelAttnSettingFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.70 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter. |
| STR rx4enumAttnSettingFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.71 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueAttnSettingFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.72 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db |
| INT rx4stateFlagAttnSettingFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.73 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelSwModeSettingFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.74 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter. |
| STR rx4enumSwModeSettingFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.75 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueSwModeSettingFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.76 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagSwModeSettingFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.77 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelSwModeThresholdFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.78 | DisplayString | read-only | The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter. |
| STR rx4enumSwModeThresholdFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.79 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueSwModeThresholdFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.80 | INTEGER | read-write | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
| INT rx4stateFlagSwModeThresholdFour | 1.3.6.1.4.1.1166.6.1.2.29.3.2.81 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelModuleConfig | 1.3.6.1.4.1.1166.6.1.2.29.3.2.82 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR rx4enumModuleConfig | 1.3.6.1.4.1.1166.6.1.2.29.3.2.83 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueModuleConfig | 1.3.6.1.4.1.1166.6.1.2.29.3.2.84 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagModuleConfig | 1.3.6.1.4.1.1166.6.1.2.29.3.2.85 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelRevertTime | 1.3.6.1.4.1.1166.6.1.2.29.3.2.86 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR rx4enumRevertTime | 1.3.6.1.4.1.1166.6.1.2.29.3.2.87 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueRevertTime | 1.3.6.1.4.1.1166.6.1.2.29.3.2.88 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagRevertTime | 1.3.6.1.4.1.1166.6.1.2.29.3.2.89 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelTestPointSelect | 1.3.6.1.4.1.1166.6.1.2.29.3.2.90 | DisplayString | read-only | The value of this object provides the label of the Test point Select Digital parameter. |
| STR rx4enumTestPointSelect | 1.3.6.1.4.1.1166.6.1.2.29.3.2.91 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueTestPointSelect | 1.3.6.1.4.1.1166.6.1.2.29.3.2.92 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagTestPointSelect | 1.3.6.1.4.1.1166.6.1.2.29.3.2.93 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.29.3.2.94 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR rx4enumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.29.3.2.95 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx4valueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.29.3.2.96 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx4stateFlagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.29.3.2.97 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Rx200BX4StatusTable | 1.3.6.1.4.1.1166.6.1.2.29.4 | not-accessible | This table contains gx2Rx200BX4 specific parameters with nominal and current values. | |
| gx2Rx200BX4StatusEntry | 1.3.6.1.4.1.1166.6.1.2.29.4.3 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Rx200BX4StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.29.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR rx4labelBoot | 1.3.6.1.4.1.1166.6.1.2.29.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT rx4valueBoot | 1.3.6.1.4.1.1166.6.1.2.29.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx4stateflagBoot | 1.3.6.1.4.1.1166.6.1.2.29.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelFlash | 1.3.6.1.4.1.1166.6.1.2.29.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT rx4valueFlash | 1.3.6.1.4.1.1166.6.1.2.29.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx4stateflagFlash | 1.3.6.1.4.1.1166.6.1.2.29.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.29.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT rx4valueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.29.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx4stateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.29.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.29.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Alarm Data CRC Status parameter. |
| INT rx4valueAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.29.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx4stateflagAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.29.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.29.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| INT rx4valueCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.29.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx4stateflagCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.29.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelHW | 1.3.6.1.4.1.1166.6.1.2.29.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Hardware Status parameter. |
| INT rx4valueHW | 1.3.6.1.4.1.1166.6.1.2.29.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx4stateflagHW | 1.3.6.1.4.1.1166.6.1.2.29.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelOptSigOne | 1.3.6.1.4.1.1166.6.1.2.29.4.3.20 | DisplayString | read-only | The value of this object provides the label of the Optical Signal Status parameter. |
| INT rx4valueOptSigOne | 1.3.6.1.4.1.1166.6.1.2.29.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx4stateflagOptSigOne | 1.3.6.1.4.1.1166.6.1.2.29.4.3.22 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelOptSigTwo | 1.3.6.1.4.1.1166.6.1.2.29.4.3.23 | DisplayString | read-only | The value of this object provides the label of the Optical Signal Status parameter. |
| INT rx4valueOptSigTwo | 1.3.6.1.4.1.1166.6.1.2.29.4.3.24 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx4stateflagOptSigTwo | 1.3.6.1.4.1.1166.6.1.2.29.4.3.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelOptSigThree | 1.3.6.1.4.1.1166.6.1.2.29.4.3.26 | DisplayString | read-only | The value of this object provides the label of the Optical Signal Status parameter. |
| INT rx4valueOptSigThree | 1.3.6.1.4.1.1166.6.1.2.29.4.3.27 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx4stateflagOptSigThree | 1.3.6.1.4.1.1166.6.1.2.29.4.3.28 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelOptSigFour | 1.3.6.1.4.1.1166.6.1.2.29.4.3.29 | DisplayString | read-only | The value of this object provides the label of the Optical Signal Status parameter. |
| INT rx4valueOptSigFour | 1.3.6.1.4.1.1166.6.1.2.29.4.3.30 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx4stateflagOptSigFour | 1.3.6.1.4.1.1166.6.1.2.29.4.3.31 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx4labelBackupCable | 1.3.6.1.4.1.1166.6.1.2.29.4.3.32 | DisplayString | read-only | The value of this object provides the label of the Backup Cable Status parameter. |
| INT rx4valueBackupCable | 1.3.6.1.4.1.1166.6.1.2.29.4.3.33 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx4stateflagBackupCable | 1.3.6.1.4.1.1166.6.1.2.29.4.3.34 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Rx200BX4FactoryTable | 1.3.6.1.4.1.1166.6.1.2.29.5 | not-accessible | This table contains gx2Rx200BX4 specific parameters with nominal and current values. | |
| gx2Rx200BX4FactoryEntry | 1.3.6.1.4.1.1166.6.1.2.29.5.4 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Rx200BX4FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.29.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT rx4bootControlByte | 1.3.6.1.4.1.1166.6.1.2.29.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT rx4bootStatusByte | 1.3.6.1.4.1.1166.6.1.2.29.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT rx4bank0CRC | 1.3.6.1.4.1.1166.6.1.2.29.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT rx4bank1CRC | 1.3.6.1.4.1.1166.6.1.2.29.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT rx4prgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.29.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT rx4factoryCRC | 1.3.6.1.4.1.1166.6.1.2.29.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT rx4calculateCRC | 1.3.6.1.4.1.1166.6.1.2.29.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT rx4hourMeter | 1.3.6.1.4.1.1166.6.1.2.29.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT rx4flashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.29.5.4.10 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side A. |
| INT rx4flashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.29.5.4.11 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side B. |
| STR rx4fwRev0 | 1.3.6.1.4.1.1166.6.1.2.29.5.4.12 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 0. |
| STR rx4fwRev1 | 1.3.6.1.4.1.1166.6.1.2.29.5.4.13 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 1. |
RFC description
Management for OMNISTAR Quad high-density return path receiver modules in HFC networks.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 RX200BX4 200 MHz quad-port optical receiver card) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.