OMNI-gx2dualdrr2x-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gx2DualDrr2x FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. -- ******************************************************************************** -- * * -- * REVISION history: * -- * MIB at Rev 0 to support Firmware at Rev A3 and below, May 31, 2012 * -- * MIB at Rev 1 to support Firmware at Rev B, June 9 2012 * -- * * -- ******************************************************************************** -- OMNISTAR Digital Receiver Return 2X Module MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2dualdrr2x Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2dualdrr2x device type. -- These parameters are common across all network elements -- from gx2dualdrr2x device type. -- -- The gx2dualdrr2x Network Elements subgroup is -- a list of gx2dualdrr2x type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies the hfcCommonTableIndex and -- gx2dualdrr2xTableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2dualdrr2x type. -- -- Both groups are mandatory for management of gx2dualdrr2x devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2dualdrr2x Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2dualdrr2x device type. -- These parameters are common across all network elements -- from gx2dualdrr2x device type. gx2dualdrr2xDescriptor OBJECT IDENTIFIER ::= {gx2DualDrr2x 1} --***************************************************************************** -- gx2dualdrr2x Table -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2dualdrr2xTableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2dualdrr2x type. -- ANALOG TABLE: -- Analog table hold analog parameters. -- For each analog parameter, there are following alarm limits: -- major high, major low, minor high and minor low. -- Firmware use these limits to determine alarm related to this parameter. Based on -- individual parameter, certain alarm limit may not be populated. -- For the unused entry, this MIB provides the following comment: -- "This object is not used by this module and always returns invalid float value -- of 0xFFFFFFFF . This object is kept here for persistence." gx2dualdrr2xAnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2dualdrr2xAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2dualdrr2x specific analog parameters with nominal,limits and current values." ::= { gx2DualDrr2x 2 } gx2dualdrr2xAnalogEntry OBJECT-TYPE SYNTAX Gx2dualdrr2xAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains the analog parameters and descriptions." INDEX { gx2dualdrr2xAnalogTableIndex } ::= { gx2dualdrr2xAnalogTable 1} --***************************************************************************** gx2dualdrr2xDigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2dualdrr2xDigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2dualdrr2x specific digital parameters with nominal and current values." ::= { gx2DualDrr2x 3 } gx2dualdrr2xDigitalEntry OBJECT-TYPE SYNTAX Gx2dualdrr2xDigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains individual digital parameters and descriptions." INDEX { gx2dualdrr2xDigitalTableIndex } ::= { gx2dualdrr2xDigitalTable 2} --***************************************************************************** gx2dualdrr2xStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2dualdrr2xStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2dualdrr2x specific status parameters with nominal and current values." ::= { gx2DualDrr2x 4 } gx2dualdrr2xStatusEntry OBJECT-TYPE SYNTAX Gx2dualdrr2xStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Status parameters and descriptions." INDEX { gx2dualdrr2xStatusTableIndex } ::= { gx2dualdrr2xStatusTable 3} --***************************************************************************** gx2dualdrr2xFactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2dualdrr2xFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2dualdrr2x specific factory setting parameters with nominal and current values." ::= { gx2DualDrr2x 5 } gx2dualdrr2xFactoryEntry OBJECT-TYPE SYNTAX Gx2dualdrr2xFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Factory setting parameters and descriptions." INDEX { gx2dualdrr2xFactoryTableIndex } ::= { gx2dualdrr2xFactoryTable 4} --************************* ANALOG PARAMETERS **************************************************** Gx2dualdrr2xAnalogEntry ::= SEQUENCE { gx2dualdrr2xAnalogTableIndex INTEGER, dualdrr2xlabelRecdOptPwr1 DisplayString (SIZE (0..80)), dualdrr2xuomRecdOptPwr1 DisplayString (SIZE (0..80)), dualdrr2xmajorHighRecdOptPwr1 Float, dualdrr2xmajorLowRecdOptPwr1 Float, dualdrr2xminorHighRecdOptPwr1 Float, dualdrr2xminorLowRecdOptPwr1 Float, dualdrr2xcurrentValueRecdOptPwr1 Float, dualdrr2xstateFlagRecdOptPwr1 INTEGER, dualdrr2xminValueRecdOptPwr1 Float, dualdrr2xmaxValueRecdOptPwr1 Float, dualdrr2xalarmStateRecdOptPwr1 INTEGER, dualdrr2xlabelRecdOptPwr2 DisplayString (SIZE (0..80)), dualdrr2xuomRecdOptPwr2 DisplayString (SIZE (0..80)), dualdrr2xmajorHighRecdOptPwr2 Float, dualdrr2xmajorLowRecdOptPwr2 Float, dualdrr2xminorHighRecdOptPwr2 Float, dualdrr2xminorLowRecdOptPwr2 Float, dualdrr2xcurrentValueRecdOptPwr2 Float, dualdrr2xstateFlagRecdOptPwr2 INTEGER, dualdrr2xminValueRecdOptPwr2 Float, dualdrr2xmaxValueRecdOptPwr2 Float, dualdrr2xalarmStateRecdOptPwr2 INTEGER, dualdrr2xlabelModTemp DisplayString (SIZE (0..80)), dualdrr2xuomModTemp DisplayString (SIZE (0..80)), dualdrr2xmajorHighModTemp Float, dualdrr2xmajorLowModTemp Float, dualdrr2xminorHighModTemp Float, dualdrr2xminorLowModTemp Float, dualdrr2xcurrentValueModTemp Float, dualdrr2xstateFlagModTemp INTEGER, dualdrr2xminValueModTemp Float, dualdrr2xmaxValueModTemp Float, dualdrr2xalarmStateModTemp INTEGER, dualdrr2xlabel12VCurrent DisplayString (SIZE (0..80)), dualdrr2xuom12VCurrent DisplayString (SIZE (0..80)), dualdrr2xmajorHigh12VCurrent Float, dualdrr2xmajorLow12VCurrent Float, dualdrr2xminorHigh12VCurrent Float, dualdrr2xminorLow12VCurrent Float, dualdrr2xcurrentValue12VCurrent Float, dualdrr2xstateFlag12VCurrent INTEGER, dualdrr2xminValue12VCurrent Float, dualdrr2xmaxValue12VCurrent Float, dualdrr2xalarmState12VCurrent INTEGER, dualdrr2xlabelFanSpeed DisplayString (SIZE (0..80)), dualdrr2xuomFanSpeed DisplayString (SIZE (0..80)), dualdrr2xmajorHighFanSpeed Float, dualdrr2xmajorLowFanSpeed Float, dualdrr2xminorHighFanSpeed Float, dualdrr2xminorLowFanSpeed Float, dualdrr2xcurrentValueFanSpeed Float, dualdrr2xstateFlagFanSpeed INTEGER, dualdrr2xminValueFanSpeed Float, dualdrr2xmaxValueFanSpeed Float, dualdrr2xalarmStateFanSpeed INTEGER, dualdrr2xlabelTx0SFPWave DisplayString (SIZE (0..80)), dualdrr2xuomTx0SFPWave DisplayString (SIZE (0..80)), dualdrr2xmajorHighTx0SFPWave Float, dualdrr2xmajorLowTx0SFPWave Float, dualdrr2xminorHighTx0SFPWave Float, dualdrr2xminorLowTx0SFPWave Float, dualdrr2xcurrentValueTx0SFPWave Float, dualdrr2xstateFlagTx0SFPWave INTEGER, dualdrr2xminValueTx0SFPWave Float, dualdrr2xmaxValueTx0SFPWave Float, dualdrr2xalarmStateTx0SFPWave INTEGER, dualdrr2xlabelTx0OptPwr DisplayString (SIZE (0..80)), dualdrr2xuomTx0OptPwr DisplayString (SIZE (0..80)), dualdrr2xmajorHighTx0OptPwr Float, dualdrr2xmajorLowTx0OptPwr Float, dualdrr2xminorHighTx0OptPwr Float, dualdrr2xminorLowTx0OptPwr Float, dualdrr2xcurrentValueTx0OptPwr Float, dualdrr2xstateFlagTx0OptPwr INTEGER, dualdrr2xminValueTx0OptPwr Float, dualdrr2xmaxValueTx0OptPwr Float, dualdrr2xalarmStateTx0OptPwr INTEGER, dualdrr2xlabelTx024vCurr DisplayString (SIZE (0..80)), dualdrr2xuomTx024vCurr DisplayString (SIZE (0..80)), dualdrr2xmajorHighTx024vCurr Float, dualdrr2xmajorLowTx024vCurr Float, dualdrr2xminorHighTx024vCurr Float, dualdrr2xminorLowTx024vCurr Float, dualdrr2xcurrentValueTx024vCurr Float, dualdrr2xstateFlagTx024vCurr INTEGER, dualdrr2xminValueTx024vCurr Float, dualdrr2xmaxValueTx024vCurr Float, dualdrr2xalarmStateTx024vCurr INTEGER, dualdrr2xlabelTx024Volt DisplayString (SIZE (0..80)), dualdrr2xuomTx024Volt DisplayString (SIZE (0..80)), dualdrr2xmajorHighTx024Volt Float, dualdrr2xmajorLowTx024Volt Float, dualdrr2xminorHighTx024Volt Float, dualdrr2xminorLowTx024Volt Float, dualdrr2xcurrentValueTx024Volt Float, dualdrr2xstateFlagTx024Volt INTEGER, dualdrr2xminValueTx024Volt Float, dualdrr2xmaxValueTx024Volt Float, dualdrr2xalarmStateTx024Volt INTEGER, dualdrr2xlabelTx0ModTemp DisplayString (SIZE (0..80)), dualdrr2xuomTx0ModTemp DisplayString (SIZE (0..80)), dualdrr2xmajorHighTx0ModTemp Float, dualdrr2xmajorLowTx0ModTemp Float, dualdrr2xminorHighTx0ModTemp Float, dualdrr2xminorLowTx0ModTemp Float, dualdrr2xcurrentValueTx0ModTemp Float, dualdrr2xstateFlagTx0ModTemp INTEGER, dualdrr2xminValueTx0ModTemp Float, dualdrr2xmaxValueTx0ModTemp Float, dualdrr2xalarmStateTx0ModTemp INTEGER, dualdrr2xlabelTx1SFPWave DisplayString (SIZE (0..80)), dualdrr2xuomTx1SFPWave DisplayString (SIZE (0..80)), dualdrr2xmajorHighTx1SFPWave Float, dualdrr2xmajorLowTx1SFPWave Float, dualdrr2xminorHighTx1SFPWave Float, dualdrr2xminorLowTx1SFPWave Float, dualdrr2xcurrentValueTx1SFPWave Float, dualdrr2xstateFlagTx1SFPWave INTEGER, dualdrr2xminValueTx1SFPWave Float, dualdrr2xmaxValueTx1SFPWave Float, dualdrr2xalarmStateTx1SFPWave INTEGER, dualdrr2xlabelTx1OptPwr DisplayString (SIZE (0..80)), dualdrr2xuomTx1OptPwr DisplayString (SIZE (0..80)), dualdrr2xmajorHighTx1OptPwr Float, dualdrr2xmajorLowTx1OptPwr Float, dualdrr2xminorHighTx1OptPwr Float, dualdrr2xminorLowTx1OptPwr Float, dualdrr2xcurrentValueTx1OptPwr Float, dualdrr2xstateFlagTx1OptPwr INTEGER, dualdrr2xminValueTx1OptPwr Float, dualdrr2xmaxValueTx1OptPwr Float, dualdrr2xalarmStateTx1OptPwr INTEGER, dualdrr2xlabelTx124vCurr DisplayString (SIZE (0..80)), dualdrr2xuomTx124vCurr DisplayString (SIZE (0..80)), dualdrr2xmajorHighTx124vCurr Float, dualdrr2xmajorLowTx124vCurr Float, dualdrr2xminorHighTx124vCurr Float, dualdrr2xminorLowTx124vCurr Float, dualdrr2xcurrentValueTx124vCurr Float, dualdrr2xstateFlagTx124vCurr INTEGER, dualdrr2xminValueTx124vCurr Float, dualdrr2xmaxValueTx124vCurr Float, dualdrr2xalarmStateTx124vCurr INTEGER, dualdrr2xlabelTx124Volt DisplayString (SIZE (0..80)), dualdrr2xuomTx124Volt DisplayString (SIZE (0..80)), dualdrr2xmajorHighTx124Volt Float, dualdrr2xmajorLowTx124Volt Float, dualdrr2xminorHighTx124Volt Float, dualdrr2xminorLowTx124Volt Float, dualdrr2xcurrentValueTx124Volt Float, dualdrr2xstateFlagTx124Volt INTEGER, dualdrr2xminValueTx124Volt Float, dualdrr2xmaxValueTx124Volt Float, dualdrr2xalarmStateTx124Volt INTEGER, dualdrr2xlabelTx1ModTemp DisplayString (SIZE (0..80)), dualdrr2xuomTx1ModTemp DisplayString (SIZE (0..80)), dualdrr2xmajorHighTx1ModTemp Float, dualdrr2xmajorLowTx1ModTemp Float, dualdrr2xminorHighTx1ModTemp Float, dualdrr2xminorLowTx1ModTemp Float, dualdrr2xcurrentValueTx1ModTemp Float, dualdrr2xstateFlagTx1ModTemp INTEGER, dualdrr2xminValueTx1ModTemp Float, dualdrr2xmaxValueTx1ModTemp Float, dualdrr2xalarmStateTx1ModTemp INTEGER } -- **************** Digital Parameters *********************** Gx2dualdrr2xDigitalEntry ::= SEQUENCE { gx2dualdrr2xDigitalTableIndex INTEGER, dualdrr2xlabelTrippoint1Value DisplayString (SIZE (0..80)), dualdrr2xenumTrippoint1Value DisplayString (SIZE (0..80)), dualdrr2xvalueTrippoint1Value INTEGER, dualdrr2xstateflagTrippoint1Value INTEGER, dualdrr2xlabelTrippoint1Mode DisplayString (SIZE (0..80)), dualdrr2xenumTrippoint1Mode DisplayString (SIZE (0..80)), dualdrr2xvalueTrippoint1Mode INTEGER, dualdrr2xstateflagTrippoint1Mode INTEGER, dualdrr2xlabelTrippoint2Value DisplayString (SIZE (0..80)), dualdrr2xenumTrippoint2Value DisplayString (SIZE (0..80)), dualdrr2xvalueTrippoint2Value INTEGER, dualdrr2xstateflagTrippoint2Value INTEGER, dualdrr2xlabelTrippoint2Mode DisplayString (SIZE (0..80)), dualdrr2xenumTrippoint2Mode DisplayString (SIZE (0..80)), dualdrr2xvalueTrippoint2Mode INTEGER, dualdrr2xstateflagTrippoint2Mode INTEGER, dualdrr2xlabelGainChannel1A DisplayString (SIZE (0..80)), dualdrr2xenumGainChannel1A DisplayString (SIZE (0..80)), dualdrr2xvalueGainChannel1A INTEGER, dualdrr2xstateflagGainChannel1A INTEGER, dualdrr2xlabelGainChannel1B DisplayString (SIZE (0..80)), dualdrr2xenumGainChannel1B DisplayString (SIZE (0..80)), dualdrr2xvalueGainChannel1B INTEGER, dualdrr2xstateflagGainChannel1B INTEGER, dualdrr2xlabelGainChannel2A DisplayString (SIZE (0..80)), dualdrr2xenumGainChannel2A DisplayString (SIZE (0..80)), dualdrr2xvalueGainChannel2A INTEGER, dualdrr2xstateflagGainChannel2A INTEGER, dualdrr2xlabelGainChannel2B DisplayString (SIZE (0..80)), dualdrr2xenumGainChannel2B DisplayString (SIZE (0..80)), dualdrr2xvalueGainChannel2B INTEGER, dualdrr2xstateflagGainChannel2B INTEGER, dualdrr2xlabelTestpointSelect DisplayString (SIZE (0..80)), dualdrr2xenumTestpointSelect DisplayString (SIZE (0..80)), dualdrr2xvalueTestpointSelect INTEGER, dualdrr2xstateflagTestpointSelect INTEGER, dualdrr2xlabelOpFrequency DisplayString (SIZE (0..80)), dualdrr2xenumOpFrequency DisplayString (SIZE (0..80)), dualdrr2xvalueOpFrequency INTEGER, dualdrr2xstateflagOpFrequency INTEGER, dualdrr2xlabelActChanSelect DisplayString (SIZE (0..80)), dualdrr2xenumActChanSelect DisplayString (SIZE (0..80)), dualdrr2xvalueActChanSelect INTEGER, dualdrr2xstateflagActChanSelect INTEGER, dualdrr2xlabelFactoryDefaultReset DisplayString (SIZE (0..80)), dualdrr2xenumFactoryDefaultReset DisplayString (SIZE (0..80)), dualdrr2xvalueFactoryDefaultReset INTEGER, dualdrr2xstateflagFactoryDefaultReset INTEGER } -- **************** Status Parameters ************************************ Gx2dualdrr2xStatusEntry ::= SEQUENCE { gx2dualdrr2xStatusTableIndex INTEGER, dualdrr2xlabelBoot DisplayString (SIZE (0..80)), dualdrr2xvalueBoot INTEGER, dualdrr2xstateflagBoot INTEGER, dualdrr2xlabelFlash DisplayString (SIZE (0..80)), dualdrr2xvalueFlash INTEGER, dualdrr2xstateflagFlash INTEGER, dualdrr2xlabelFactoryDataCRC DisplayString (SIZE (0..80)), dualdrr2xvalueFactoryDataCRC INTEGER, dualdrr2xstateflagFactoryDataCRC INTEGER, dualdrr2xlabelAlarmDataCrc DisplayString (SIZE (0..80)), dualdrr2xvalueAlarmDataCrc INTEGER, dualdrr2xstateflagAlarmDataCrc INTEGER, dualdrr2xlabelCalibrationDataCrc DisplayString (SIZE (0..80)), dualdrr2xvalueCalibrationDataCrc INTEGER, dualdrr2xstateflagCalibrationDataCrc INTEGER, dualdrr2xlabelHardwareStatus DisplayString (SIZE (0..80)), dualdrr2xvalueHardwareStatus INTEGER, dualdrr2xstateflagHardwareStatus INTEGER, dualdrr2xlabelCh1TripPointStatus DisplayString (SIZE (0..80)), dualdrr2xvalueCh1TripPointStatus INTEGER, dualdrr2xstateflagCh1TripPointStatus INTEGER, dualdrr2xlabelLink1Status DisplayString (SIZE (0..80)), dualdrr2xvalueLink1Status INTEGER, dualdrr2xstateflagLink1Status INTEGER, dualdrr2xlabelCh2TripPointStatus DisplayString (SIZE (0..80)), dualdrr2xvalueCh2TripPointStatus INTEGER, dualdrr2xstateflagCh2TripPointStatus INTEGER, dualdrr2xlabelLink2Status DisplayString (SIZE (0..80)), dualdrr2xvalueLink2Status INTEGER, dualdrr2xstateflagLink2Status INTEGER, dualdrr2xlabelDRT1Status DisplayString (SIZE (0..80)), dualdrr2xvalueDRT1Status INTEGER, dualdrr2xstateflagDRT1Status INTEGER, dualdrr2xlabelSFP0Status DisplayString (SIZE (0..80)), dualdrr2xvalueSFP0Status INTEGER, dualdrr2xstateflagSFP0Status INTEGER, dualdrr2xlabelDRT2Status DisplayString (SIZE (0..80)), dualdrr2xvalueDRT2Status INTEGER, dualdrr2xstateflagDRT2Status INTEGER, dualdrr2xlabelSFP1Status DisplayString (SIZE (0..80)), dualdrr2xvalueSFP1Status INTEGER, dualdrr2xstateflagSFP1Status INTEGER } -- **************** Factory Parameters ************************************* Gx2dualdrr2xFactoryEntry ::= SEQUENCE { gx2dualdrr2xFactoryTableIndex INTEGER, dualdrr2xbootControlByte INTEGER, dualdrr2xbootStatusByte INTEGER, dualdrr2xbank1CRC INTEGER, dualdrr2xbank2CRC INTEGER, dualdrr2xprgEEPROMByte INTEGER, dualdrr2xfactoryCRC INTEGER, dualdrr2xcalculateCRC INTEGER, dualdrr2xhourMeter INTEGER, dualdrr2xflashPrgCntA INTEGER, dualdrr2xflashPrgCntB INTEGER, dualdrr2xflashBankARev DisplayString (SIZE (0..80)), dualdrr2xflashBankBRev DisplayString (SIZE (0..80)), dualdrr2xSubAgentRev DisplayString (SIZE (0..80)), dualdrr2xFPGA0FwRev DisplayString (SIZE (0..80)), dualdrr2xFPGA1FwRev DisplayString (SIZE (0..80)), dualdrr2xDRT1SerialNo DisplayString (SIZE (0..80)), dualdrr2xDRT1FwRev DisplayString (SIZE (0..80)), dualdrr2xDRT1FpgaFwRev DisplayString (SIZE (0..80)), dualdrr2xDRT1SFPSerialNo DisplayString (SIZE (0..80)), dualdrr2xDRT1SFPPartNo DisplayString (SIZE (0..80)), dualdrr2xDRT2SerialNo DisplayString (SIZE (0..80)), dualdrr2xDRT2FwRev DisplayString (SIZE (0..80)), dualdrr2xDRT2FpgaFwRev DisplayString (SIZE (0..80)), dualdrr2xDRT2SFPSerialNo DisplayString (SIZE (0..80)), dualdrr2xDRT2SFPPartNo DisplayString (SIZE (0..80)) } -- ************** Analog Parameters **************************** gx2dualdrr2xAnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2dualdrr2xAnalogEntry 1} -- RecdOptPwr1 dualdrr2xlabelRecdOptPwr1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Channel 1 Received Opt power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 2} dualdrr2xuomRecdOptPwr1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Channel 1 Received Opt power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 3} dualdrr2xmajorHighRecdOptPwr1 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns the value of the Channel 1 Received Opt power Major High Alarm Limit Analog parameter." ::= { gx2dualdrr2xAnalogEntry 4} dualdrr2xmajorLowRecdOptPwr1 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns the value of the Channel 1 Received Opt power Major High Alarm Limit Analog parameter." ::= { gx2dualdrr2xAnalogEntry 5} dualdrr2xminorHighRecdOptPwr1 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 6} dualdrr2xminorLowRecdOptPwr1 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 7} dualdrr2xcurrentValueRecdOptPwr1 OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Channel 1 Received Opt power." ::= { gx2dualdrr2xAnalogEntry 8} dualdrr2xstateFlagRecdOptPwr1 OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Channel 1 Received Opt power Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 9} dualdrr2xminValueRecdOptPwr1 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Channel 1 Received Opt power." ::= { gx2dualdrr2xAnalogEntry 10} dualdrr2xmaxValueRecdOptPwr1 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Channel 1 Received Opt power." ::= { gx2dualdrr2xAnalogEntry 11} dualdrr2xalarmStateRecdOptPwr1 OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Channel 1 Received Opt power." ::= { gx2dualdrr2xAnalogEntry 12} -- RecdOptPwr2 dualdrr2xlabelRecdOptPwr2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Channel 2 Received Opt power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 13} dualdrr2xuomRecdOptPwr2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Channel 2 Received Opt power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 14} dualdrr2xmajorHighRecdOptPwr2 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter." ::= { gx2dualdrr2xAnalogEntry 15} dualdrr2xmajorLowRecdOptPwr2 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter." ::= { gx2dualdrr2xAnalogEntry 16} dualdrr2xminorHighRecdOptPwr2 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 17} dualdrr2xminorLowRecdOptPwr2 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 18} dualdrr2xcurrentValueRecdOptPwr2 OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Channel 2 Received Opt power." ::= { gx2dualdrr2xAnalogEntry 19} dualdrr2xstateFlagRecdOptPwr2 OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Channel 2 Received Opt power Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 20} dualdrr2xminValueRecdOptPwr2 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Channel 2 Received Opt power." ::= { gx2dualdrr2xAnalogEntry 21} dualdrr2xmaxValueRecdOptPwr2 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Channel 2 Received Opt power." ::= { gx2dualdrr2xAnalogEntry 22} dualdrr2xalarmStateRecdOptPwr2 OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Channel 2 Received optical power." ::= { gx2dualdrr2xAnalogEntry 23} -- Module Temperature dualdrr2xlabelModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 24} dualdrr2xuomModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 25} dualdrr2xmajorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 26} dualdrr2xmajorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 27} dualdrr2xminorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 28} dualdrr2xminorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 29} dualdrr2xcurrentValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 30} dualdrr2xstateFlagModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 31} dualdrr2xminValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Module Temperature Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 32} dualdrr2xmaxValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Module Temperature Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 33} dualdrr2xalarmStateModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 34} -- 12V current dualdrr2xlabel12VCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the 12v power supply Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 35} dualdrr2xuom12VCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 36} dualdrr2xmajorHigh12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 37} dualdrr2xmajorLow12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 38} dualdrr2xminorHigh12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 39} dualdrr2xminorLow12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 40} dualdrr2xcurrentValue12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the 12v power supply Current parameter." ::= { gx2dualdrr2xAnalogEntry 41} dualdrr2xstateFlag12VCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the 12v power supply Current Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 42} dualdrr2xminValue12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 43} dualdrr2xmaxValue12VCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 44} dualdrr2xalarmState12VCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 45} -- Fan Speed dualdrr2xlabelFanSpeed OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Speed Analog parameter." ::= { gx2dualdrr2xAnalogEntry 46} dualdrr2xuomFanSpeed OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Speed Analog parameter." ::= { gx2dualdrr2xAnalogEntry 47} dualdrr2xmajorHighFanSpeed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Speed Analog parameter." ::= { gx2dualdrr2xAnalogEntry 48} dualdrr2xmajorLowFanSpeed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Speed Analog parameter." ::= { gx2dualdrr2xAnalogEntry 49} dualdrr2xminorHighFanSpeed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 50} dualdrr2xminorLowFanSpeed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 51} dualdrr2xcurrentValueFanSpeed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Fan Speed Analog parameter." ::= { gx2dualdrr2xAnalogEntry 52} dualdrr2xstateFlagFanSpeed OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Speed Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 53} dualdrr2xminValueFanSpeed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Fan Speed Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 54} dualdrr2xmaxValueFanSpeed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Fan Speed Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 55} dualdrr2xalarmStateFanSpeed OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Speed Analog parameter." ::= { gx2dualdrr2xAnalogEntry 56} -- Transmitter 0 SFP Wavelength dualdrr2xlabelTx0SFPWave OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Tx 0 SFP Wavelength Analog parameter." ::= { gx2dualdrr2xAnalogEntry 57} dualdrr2xuomTx0SFPWave OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Tx 0 SFP Wavelength Analog parameter." ::= { gx2dualdrr2xAnalogEntry 58} dualdrr2xmajorHighTx0SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Tx 0 SFP Wavelength Analog parameter." ::= { gx2dualdrr2xAnalogEntry 59} dualdrr2xmajorLowTx0SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Tx 0 SFP Wavelength Analog parameter." ::= { gx2dualdrr2xAnalogEntry 60} dualdrr2xminorHighTx0SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 61} dualdrr2xminorLowTx0SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 62} dualdrr2xcurrentValueTx0SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Tx 0 SFP Wavelength Analog parameter." ::= { gx2dualdrr2xAnalogEntry 63} dualdrr2xstateFlagTx0SFPWave OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Tx 0 SFP Wavelength Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 64} dualdrr2xminValueTx0SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Tx 0 SFP Wavelength Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 65} dualdrr2xmaxValueTx0SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Tx 0 SFP Wavelength Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 66} dualdrr2xalarmStateTx0SFPWave OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Tx 0 SFP Wavelength Analog parameter." ::= { gx2dualdrr2xAnalogEntry 67} -- Transmitter 0 Optical power dualdrr2xlabelTx0OptPwr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Tx 0 Optical Power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 68} dualdrr2xuomTx0OptPwr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Tx 0 Optical Power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 69} dualdrr2xmajorHighTx0OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Tx 0 Optical Power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 70} dualdrr2xmajorLowTx0OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Tx 0 Optical Power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 71} dualdrr2xminorHighTx0OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 72} dualdrr2xminorLowTx0OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 73} dualdrr2xcurrentValueTx0OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Tx 0 Optical Power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 74} dualdrr2xstateFlagTx0OptPwr OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Tx 0 Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 75} dualdrr2xminValueTx0OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Tx 0 Optical Power Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 76} dualdrr2xmaxValueTx0OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Tx 0 Optical Power Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 77} dualdrr2xalarmStateTx0OptPwr OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Tx 0 Optical Power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 78} -- Transmitter 0 24 Volt Current OBJECT-TYPE dualdrr2xlabelTx024vCurr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Tx 0 24 Volt Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 79} dualdrr2xuomTx024vCurr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Tx 0 24 Volt Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 80} dualdrr2xmajorHighTx024vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Tx 0 24 Volt Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 81} dualdrr2xmajorLowTx024vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Tx 0 24 Volt Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 82} dualdrr2xminorHighTx024vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 83} dualdrr2xminorLowTx024vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 84} dualdrr2xcurrentValueTx024vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Tx 0 24 Volt Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 85} dualdrr2xstateFlagTx024vCurr OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Tx 0 24 Volt Current Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 86} dualdrr2xminValueTx024vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Tx 0 24 Volt Current Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 87} dualdrr2xmaxValueTx024vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Tx 0 24 Volt Current Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 88} dualdrr2xalarmStateTx024vCurr OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Tx 0 24 Volt Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 89} -- Transmitter 0 24 Volt supply Voltage OBJECT-TYPE dualdrr2xlabelTx024Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Tx 0 24 Volt supply voltage Analog parameter." ::= { gx2dualdrr2xAnalogEntry 90} dualdrr2xuomTx024Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Tx 0 24 Volt supply voltage Analog parameter." ::= { gx2dualdrr2xAnalogEntry 91} dualdrr2xmajorHighTx024Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Tx 0 24 Volt supply voltage Analog parameter." ::= { gx2dualdrr2xAnalogEntry 92} dualdrr2xmajorLowTx024Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Tx 0 24 Volt supply voltage Analog parameter." ::= { gx2dualdrr2xAnalogEntry 93} dualdrr2xminorHighTx024Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 94} dualdrr2xminorLowTx024Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 95} dualdrr2xcurrentValueTx024Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Tx 0 24 Volt supply voltage Analog parameter." ::= { gx2dualdrr2xAnalogEntry 96} dualdrr2xstateFlagTx024Volt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Tx 0 24 Volt supply voltage Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 97} dualdrr2xminValueTx024Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Tx 0 24 Volt supply voltage Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 98} dualdrr2xmaxValueTx024Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Tx 0 24 Volt supply voltage Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 99} dualdrr2xalarmStateTx024Volt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Tx 0 24 Volt supply voltage Analog parameter." ::= { gx2dualdrr2xAnalogEntry 100} -- Transmitter 0 Module Temperature OBJECT-TYPE dualdrr2xlabelTx0ModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Tx 0 24 Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 101} dualdrr2xuomTx0ModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Tx 0 Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 102} dualdrr2xmajorHighTx0ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Tx 0 Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 103} dualdrr2xmajorLowTx0ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Tx 0 Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 104} dualdrr2xminorHighTx0ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 105} dualdrr2xminorLowTx0ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 106} dualdrr2xcurrentValueTx0ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Tx 0 Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 107} dualdrr2xstateFlagTx0ModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Tx 0 Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 108} dualdrr2xminValueTx0ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Tx 0 Module Temperature Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 109} dualdrr2xmaxValueTx0ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Tx 0 Module Temperature Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 110} dualdrr2xalarmStateTx0ModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Tx 0 Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 111} -- Transmitter 1 SFP Wavelength dualdrr2xlabelTx1SFPWave OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Tx 1 SFP Wavelength Analog parameter." ::= { gx2dualdrr2xAnalogEntry 112} dualdrr2xuomTx1SFPWave OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Tx 1 SFP Wavelength Analog parameter." ::= { gx2dualdrr2xAnalogEntry 113} dualdrr2xmajorHighTx1SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Tx 1 SFP Wavelength Analog parameter." ::= { gx2dualdrr2xAnalogEntry 114} dualdrr2xmajorLowTx1SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Tx 1 SFP Wavelength Analog parameter." ::= { gx2dualdrr2xAnalogEntry 115} dualdrr2xminorHighTx1SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 116} dualdrr2xminorLowTx1SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 117} dualdrr2xcurrentValueTx1SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Tx 1 SFP Wavelength Analog parameter." ::= { gx2dualdrr2xAnalogEntry 118} dualdrr2xstateFlagTx1SFPWave OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Tx 1 SFP Wavelength Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 119} dualdrr2xminValueTx1SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Tx 1 SFP Wavelength Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 120} dualdrr2xmaxValueTx1SFPWave OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Tx 1 SFP Wavelength Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 121} dualdrr2xalarmStateTx1SFPWave OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Tx 1 SFP Wavelength Analog parameter." ::= { gx2dualdrr2xAnalogEntry 122} -- Transmitter 1 Optical power dualdrr2xlabelTx1OptPwr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Tx 1 Optical Power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 123} dualdrr2xuomTx1OptPwr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Tx 1 Optical Power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 124} dualdrr2xmajorHighTx1OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Tx 1 Optical Power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 125} dualdrr2xmajorLowTx1OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Tx 1 Optical Power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 126} dualdrr2xminorHighTx1OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 127} dualdrr2xminorLowTx1OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 128} dualdrr2xcurrentValueTx1OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Tx 1 Optical Power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 129} dualdrr2xstateFlagTx1OptPwr OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Tx 1 Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 130} dualdrr2xminValueTx1OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Tx 1 Optical Power Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 131} dualdrr2xmaxValueTx1OptPwr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Tx 1 Optical Power Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 132} dualdrr2xalarmStateTx1OptPwr OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Tx 1 Optical Power Analog parameter." ::= { gx2dualdrr2xAnalogEntry 133} -- Transmitter 1 24 Volt Current OBJECT-TYPE dualdrr2xlabelTx124vCurr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Tx 1 24 VoltCurrent Analog parameter." ::= { gx2dualdrr2xAnalogEntry 134} dualdrr2xuomTx124vCurr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Tx 1 24 Volt Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 135} dualdrr2xmajorHighTx124vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Tx 1 24 Volt Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 136} dualdrr2xmajorLowTx124vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Tx 1 24 Volt Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 137} dualdrr2xminorHighTx124vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 138} dualdrr2xminorLowTx124vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 139} dualdrr2xcurrentValueTx124vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Tx 1 24 Volt Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 140} dualdrr2xstateFlagTx124vCurr OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Tx 1 24 Volt Current Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 141} dualdrr2xminValueTx124vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Tx 1 24 Volt Current Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 142} dualdrr2xmaxValueTx124vCurr OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Tx 1 24 Volt Current Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 143} dualdrr2xalarmStateTx124vCurr OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Tx 1 24 Volt Current Analog parameter." ::= { gx2dualdrr2xAnalogEntry 144} -- Transmitter 1 24 Volt supply Voltage OBJECT-TYPE dualdrr2xlabelTx124Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Tx 1 24 Volt supply voltage Analog parameter." ::= { gx2dualdrr2xAnalogEntry 145} dualdrr2xuomTx124Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Tx 1 24 Volt supply voltage Analog parameter." ::= { gx2dualdrr2xAnalogEntry 146} dualdrr2xmajorHighTx124Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Tx 1 24 Volt supply voltage Analog parameter." ::= { gx2dualdrr2xAnalogEntry 147} dualdrr2xmajorLowTx124Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Tx 1 24 Volt supply voltage Analog parameter." ::= { gx2dualdrr2xAnalogEntry 148} dualdrr2xminorHighTx124Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 149} dualdrr2xminorLowTx124Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 150} dualdrr2xcurrentValueTx124Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Tx 1 24 Volt supply voltage Analog parameter." ::= { gx2dualdrr2xAnalogEntry 151} dualdrr2xstateFlagTx124Volt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Tx 1 24 Volt supply voltage Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 152} dualdrr2xminValueTx124Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Tx 1 24 Volt supply voltage Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 153} dualdrr2xmaxValueTx124Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Tx 1 24 Volt supply voltage Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 154} dualdrr2xalarmStateTx124Volt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Tx 1 24 Volt supply voltage Analog parameter." ::= { gx2dualdrr2xAnalogEntry 155} -- Transmitter 1 Module Temperature OBJECT-TYPE dualdrr2xlabelTx1ModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Tx 1 24 Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 156} dualdrr2xuomTx1ModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Tx 1 Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 157} dualdrr2xmajorHighTx1ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Tx 1 Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 158} dualdrr2xmajorLowTx1ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Tx 1 Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 159} dualdrr2xminorHighTx1ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 160} dualdrr2xminorLowTx1ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence." ::= { gx2dualdrr2xAnalogEntry 161} dualdrr2xcurrentValueTx1ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Tx 1 Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 162} dualdrr2xstateFlagTx1ModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Tx 1 Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2dualdrr2xAnalogEntry 163} dualdrr2xminValueTx1ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Tx 1 Module Temperature Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 164} dualdrr2xmaxValueTx1ModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Tx 1 Module Temperature Analog parameter can achive." ::= { gx2dualdrr2xAnalogEntry 165} dualdrr2xalarmStateTx1ModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Tx 1 Module Temperature Analog parameter." ::= { gx2dualdrr2xAnalogEntry 166} -- ************************ Digital parameters ********************************** gx2dualdrr2xDigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2dualdrr2xDigitalEntry 1} -- Trip point Value 1 dualdrr2xlabelTrippoint1Value OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Trip point Value Digital parameter. The trip point Value defines the RF switch point based on the optical power input to the DRR" ::= { gx2dualdrr2xDigitalEntry 2} dualdrr2xenumTrippoint1Value OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. " ::= { gx2dualdrr2xDigitalEntry 3} dualdrr2xvalueTrippoint1Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the threshold at which the Trip point activates. It is in 1 dB increments ranging from -25 to -5 dB. The user can enter a number from 0 to 20, where 0 = -5db and 19 = -25db" ::= { gx2dualdrr2xDigitalEntry 4} dualdrr2xstateflagTrippoint1Value OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xDigitalEntry 5} -- Trip point mode 1 dualdrr2xlabelTrippoint1Mode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical power input to the DRR" ::= { gx2dualdrr2xDigitalEntry 6} dualdrr2xenumTrippoint1Mode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. " ::= { gx2dualdrr2xDigitalEntry 7} dualdrr2xvalueTrippoint1Mode OBJECT-TYPE SYNTAX INTEGER{ off(1), alarmOnly(2), alarm-and-Switch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical power is higher than the preset trippoint value, no operational difference for these three modes. If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml" ::= { gx2dualdrr2xDigitalEntry 8} dualdrr2xstateflagTrippoint1Mode OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xDigitalEntry 9} -- Trip point Value 2 dualdrr2xlabelTrippoint2Value OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Trip point Value Digital parameter. The trip point Value defines the RF switch point based on the optical power input to the DRR" ::= { gx2dualdrr2xDigitalEntry 10} dualdrr2xenumTrippoint2Value OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. " ::= { gx2dualdrr2xDigitalEntry 11} dualdrr2xvalueTrippoint2Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the threshold at which the Trip point activates. It is in 1 dB increments ranging from -25 to -5 dB. The user can enter a number from 0 to 20, where 0 = -5db and 19 = -25db" ::= { gx2dualdrr2xDigitalEntry 12} dualdrr2xstateflagTrippoint2Value OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xDigitalEntry 13} -- Trip point mode 2 dualdrr2xlabelTrippoint2Mode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical power input to the DRR" ::= { gx2dualdrr2xDigitalEntry 14} dualdrr2xenumTrippoint2Mode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. " ::= { gx2dualdrr2xDigitalEntry 15} dualdrr2xvalueTrippoint2Mode OBJECT-TYPE SYNTAX INTEGER{ off(1), alarmOnly(2), alarm-and-Switch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical power is higher than the preset trippoint value, no operational difference for these three modes. If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml" ::= { gx2dualdrr2xDigitalEntry 16} dualdrr2xstateflagTrippoint2Mode OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xDigitalEntry 17} -- RF Channel 1A Gain dualdrr2xlabelGainChannel1A OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Channel 1A Gain Digital parameter. " ::= { gx2dualdrr2xDigitalEntry 18} dualdrr2xenumGainChannel1A OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. " ::= { gx2dualdrr2xDigitalEntry 19} dualdrr2xvalueGainChannel1A OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the gain for RF Channel 1A. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from 0 to 20" ::= { gx2dualdrr2xDigitalEntry 20} dualdrr2xstateflagGainChannel1A OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xDigitalEntry 21} -- RF Channel 1B Gain dualdrr2xlabelGainChannel1B OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Channel 1B Gain Digital parameter. " ::= { gx2dualdrr2xDigitalEntry 22} dualdrr2xenumGainChannel1B OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. " ::= { gx2dualdrr2xDigitalEntry 23} dualdrr2xvalueGainChannel1B OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the gain for RF Channel 1B. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from 0 to 20" ::= { gx2dualdrr2xDigitalEntry 24} dualdrr2xstateflagGainChannel1B OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xDigitalEntry 25} -- RF Channel 2A Gain dualdrr2xlabelGainChannel2A OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Channel 2A Gain Digital parameter. " ::= { gx2dualdrr2xDigitalEntry 26} dualdrr2xenumGainChannel2A OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. " ::= { gx2dualdrr2xDigitalEntry 27} dualdrr2xvalueGainChannel2A OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the gain for RF Channel 2A. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from 0 to 20" ::= { gx2dualdrr2xDigitalEntry 28} dualdrr2xstateflagGainChannel2A OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xDigitalEntry 29} -- RF Channel 2B Gain dualdrr2xlabelGainChannel2B OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Channel 2B Gain Digital parameter. " ::= { gx2dualdrr2xDigitalEntry 30} dualdrr2xenumGainChannel2B OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. " ::= { gx2dualdrr2xDigitalEntry 31} dualdrr2xvalueGainChannel2B OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the gain for RF Channel 2B. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from 0 to 20" ::= { gx2dualdrr2xDigitalEntry 32} dualdrr2xstateflagGainChannel2B OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xDigitalEntry 33} -- Testpoint Select dualdrr2xlabelTestpointSelect OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module's test point select Digital parameter. " ::= { gx2dualdrr2xDigitalEntry 34} dualdrr2xenumTestpointSelect OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. " ::= { gx2dualdrr2xDigitalEntry 35} dualdrr2xvalueTestpointSelect OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), three(3), four(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the test point selector for The Module. The user can enter a number from 1 to 4" ::= { gx2dualdrr2xDigitalEntry 36} dualdrr2xstateflagTestpointSelect OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xDigitalEntry 37} -- Active Channel Select dualdrr2xlabelOpFrequency OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module's active channels Digital parameter. " ::= { gx2dualdrr2xDigitalEntry 38} dualdrr2xenumOpFrequency OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. " ::= { gx2dualdrr2xDigitalEntry 39} dualdrr2xvalueOpFrequency OBJECT-TYPE SYNTAX INTEGER { eightyfive(1), sixtyfive(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects which channels are active for The Module. The user can enter a number from 1 to 4" ::= { gx2dualdrr2xDigitalEntry 40} dualdrr2xstateflagOpFrequency OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xDigitalEntry 41} -- Active Channel Select dualdrr2xlabelActChanSelect OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module's active channels Digital parameter. " ::= { gx2dualdrr2xDigitalEntry 42} dualdrr2xenumActChanSelect OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. " ::= { gx2dualdrr2xDigitalEntry 43} dualdrr2xvalueActChanSelect OBJECT-TYPE SYNTAX INTEGER { none(1), channel1(2), channel2(3), both(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects which channels are active for The Module. The user can enter a number from 1 to 4" ::= { gx2dualdrr2xDigitalEntry 44} dualdrr2xstateflagActChanSelect OBJECT-TYPE SYNTAX INTEGER { hidden(1), readOnly(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xDigitalEntry 45} -- Factory default reset dualdrr2xlabelFactoryDefaultReset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2dualdrr2xDigitalEntry 46} dualdrr2xenumFactoryDefaultReset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2dualdrr2xDigitalEntry 47} dualdrr2xvalueFactoryDefaultReset OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter " ::= { gx2dualdrr2xDigitalEntry 48} dualdrr2xstateflagFactoryDefaultReset OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xDigitalEntry 49} --*********** STATUS ***************** gx2dualdrr2xStatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2dualdrr2xStatusEntry 1} --Boot status dualdrr2xlabelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status parameter." ::= { gx2dualdrr2xStatusEntry 2} dualdrr2xvalueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 3} dualdrr2xstateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 4} --Flash program status dualdrr2xlabelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status parameter." ::= { gx2dualdrr2xStatusEntry 5} dualdrr2xvalueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 6} dualdrr2xstateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 7} --Factory data crc dualdrr2xlabelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2dualdrr2xStatusEntry 8} dualdrr2xvalueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 9} dualdrr2xstateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 10} --Alarm data status CRC dualdrr2xlabelAlarmDataCrc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2dualdrr2xStatusEntry 11} dualdrr2xvalueAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 12} dualdrr2xstateflagAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 13} --Calibration data status CRC dualdrr2xlabelCalibrationDataCrc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Calibration Data Crc parameter." ::= { gx2dualdrr2xStatusEntry 14} dualdrr2xvalueCalibrationDataCrc OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 15} dualdrr2xstateflagCalibrationDataCrc OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 16} --Module hardware status dualdrr2xlabelHardwareStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Hardware Status parameter." ::= { gx2dualdrr2xStatusEntry 17} dualdrr2xvalueHardwareStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 18} dualdrr2xstateflagHardwareStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 19} --Channel 1 trip point status dualdrr2xlabelCh1TripPointStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip point value" ::= { gx2dualdrr2xStatusEntry 20} dualdrr2xvalueCh1TripPointStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 21} dualdrr2xstateflagCh1TripPointStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 22} --Link 1 Status dualdrr2xlabelLink1Status OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal." ::= { gx2dualdrr2xStatusEntry 23} dualdrr2xvalueLink1Status OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 24} dualdrr2xstateflagLink1Status OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 25} --Channel 2 trip point status dualdrr2xlabelCh2TripPointStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip point value" ::= { gx2dualdrr2xStatusEntry 26} dualdrr2xvalueCh2TripPointStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 27} dualdrr2xstateflagCh2TripPointStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 28} --Link 2 Status dualdrr2xlabelLink2Status OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal." ::= { gx2dualdrr2xStatusEntry 29} dualdrr2xvalueLink2Status OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 30} dualdrr2xstateflagLink2Status OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 31} --DRT 0 Status dualdrr2xlabelDRT1Status OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal." ::= { gx2dualdrr2xStatusEntry 32} dualdrr2xvalueDRT1Status OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 33} dualdrr2xstateflagDRT1Status OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 34} --SFP 0 Status dualdrr2xlabelSFP0Status OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal." ::= { gx2dualdrr2xStatusEntry 35} dualdrr2xvalueSFP0Status OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 36} dualdrr2xstateflagSFP0Status OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 37} --DRT 1 Status dualdrr2xlabelDRT2Status OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal." ::= { gx2dualdrr2xStatusEntry 38} dualdrr2xvalueDRT2Status OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 39} dualdrr2xstateflagDRT2Status OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 40} --SFP 1 Status dualdrr2xlabelSFP1Status OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal." ::= { gx2dualdrr2xStatusEntry 41} dualdrr2xvalueSFP1Status OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical)." ::= { gx2dualdrr2xStatusEntry 42} dualdrr2xstateflagSFP1Status OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable)." ::= { gx2dualdrr2xStatusEntry 43} -- ************ FACTORY DATA **************** gx2dualdrr2xFactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2dualdrr2xFactoryEntry 1} dualdrr2xbootControlByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2dualdrr2xFactoryEntry 2} dualdrr2xbootStatusByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot" ::= { gx2dualdrr2xFactoryEntry 3} dualdrr2xbank1CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0." ::= { gx2dualdrr2xFactoryEntry 4} dualdrr2xbank2CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1." ::= { gx2dualdrr2xFactoryEntry 5} dualdrr2xprgEEPROMByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2dualdrr2xFactoryEntry 6} dualdrr2xfactoryCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2dualdrr2xFactoryEntry 7} dualdrr2xcalculateCRC OBJECT-TYPE SYNTAX INTEGER { factory(1), alarm(2), calibration(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which of the Emnums will have the CRC calculated (1-factory, 2-alarm, 3-calibration)." ::= { gx2dualdrr2xFactoryEntry 8} dualdrr2xhourMeter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2dualdrr2xFactoryEntry 9} dualdrr2xflashPrgCntA OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 0 flash has been programmed." ::= { gx2dualdrr2xFactoryEntry 10} dualdrr2xflashPrgCntB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2dualdrr2xFactoryEntry 11} dualdrr2xflashBankARev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 0." ::= { gx2dualdrr2xFactoryEntry 12} dualdrr2xflashBankBRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 1." ::= { gx2dualdrr2xFactoryEntry 13} dualdrr2xSubAgentRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the subagent revision of receiver module." ::= { gx2dualdrr2xFactoryEntry 14} dualdrr2xFPGA0FwRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Firmware revision of the first DRR FPGA." ::= { gx2dualdrr2xFactoryEntry 15} dualdrr2xFPGA1FwRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Firmware revision of the second DRR FPGA." ::= { gx2dualdrr2xFactoryEntry 16} dualdrr2xDRT1SerialNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Serial Number of the DRT attached to channel 1." ::= { gx2dualdrr2xFactoryEntry 17} dualdrr2xDRT1SFPSerialNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Serial Number of the SFP in the DRT attached to channel 1." ::= { gx2dualdrr2xFactoryEntry 18} dualdrr2xDRT1SFPPartNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Part number of the SFP in the DRT attached to channel 1." ::= { gx2dualdrr2xFactoryEntry 19} dualdrr2xDRT1FwRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Firmware revision of the DRT attached to channel 1." ::= { gx2dualdrr2xFactoryEntry 20} dualdrr2xDRT1FpgaFwRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Firmware revision of the FPGA in the DRT attached to channel 1." ::= { gx2dualdrr2xFactoryEntry 21} dualdrr2xDRT2SerialNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Serial Number of the DRT attached to channel 2" ::= { gx2dualdrr2xFactoryEntry 22} dualdrr2xDRT2SFPSerialNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Serial Number of the SFP in the DRT attached to channel 2" ::= { gx2dualdrr2xFactoryEntry 23} dualdrr2xDRT2SFPPartNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Part number of the SFP in the DRT attached to channel 2." ::= { gx2dualdrr2xFactoryEntry 24} dualdrr2xDRT2FwRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Firmware revision of the DRT attached to channel 2." ::= { gx2dualdrr2xFactoryEntry 25} dualdrr2xDRT2FpgaFwRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Firmware revision of the FPGA in the DRT attached to channel 2." ::= { gx2dualdrr2xFactoryEntry 26} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** -- ************************************************************************** -- Digital Receiver Return Module traps -- ************************************************************************** trapdualdrrConfigChangeInteger TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapdualdrrConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapdualdrr12VCurrentAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapdualdrrModuleTempAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapdualdrrFanSpeedAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Fan Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 5 trapdualdrrFlashAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the detects an error during Flash memory operations." ::= 6 trapdualdrrBankBootAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the module detects an error while booting from bank 0 or bank 1." ::= 7 trapdualdrrAlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Alarm Data CRC is incorrect." ::= 8 trapdualdrrHardwareErrAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when hardware is abnormal." ::= 9 trapdualdrrOpticalSignal1Alarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the optical signal 1 is beyond the preset range." ::= 10 trapdualdrrOpticalSignal2Alarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the optical signal 2 is beyond the preset range." ::= 11 trapdualdrrFactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Data CRC is incorrect." ::= 12 trapdualdrrResetFactoryDefaultAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Default Reset occurs." ::= 13 trapdualdrrTripPoint1Alarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Input 1 optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM." ::= 14 trapdualdrrTripPoint2Alarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Input 2 optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM." ::= 15 trapdualdrrLink1Alarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when receiver 1 is out of SYN with transmitter" ::= 16 trapdualdrrLink2Alarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when receiver 2 is out of SYN with transmitter" ::= 17 trapdualdrrCalibrationDataCRCAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Calibration Data CRC is incorrect" ::= 18 trapdualdrrSFP1OptPWRAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when SFP 1's optical power is incorrect" ::= 19 trapdualdrrDRT1Cur24VAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when DRT 1's 24 volt current is incorrect" ::= 20 trapdualdrrDRT1ModTempAarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when DRT 1's Module telperature is incorrect" ::= 21 trapdualdrrSFP2OptPWRAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when SFP 2's optical power is incorrect" ::= 22 trapdualdrrDRT2Cur24VAlarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when DRT 2's 24 volt current is incorrect" ::= 23 trapdualdrrDRT2ModTempAarm TRAP-TYPE ENTERPRISE gx2DualDrr2x VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when DRT 2's Module telperature is incorrect" ::= 24 END