All MIBs › OMNI-gx2Lm1000s-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 LM1000S 1000 MHz laser module in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2Lm1000s-MIB?
OMNI-gx2Lm1000s-MIB is a Blonder Tongue (BBN/GX2 HFC headend heritage) proprietary MIB reporting gx2Lm1000s (a 1000-series laser-transmitter module) analog telemetry against nominal ranges. Its analog table, keyed by index, records per-parameter (offset-from-nominal monitor, laser power, and others) label, unit of measure, major/minor high/low threshold, current value, state flag, min/max recorded value, and alarm state, while companion digital/status/factory tables cover discrete status and factory-set data. As a hardware-performance MIB it lets an administrator watch a gx2Lm1000s laser transmitter's power output against alarm thresholds in an HFC headend. It is deployed on Blonder Tongue (GX2) HFC headend equipment. Engineers can download the OMNI-gx2Lm1000s-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2Lm1000s-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (gx2Lm1000s 1000-series laser transmitter module)
Monitoring Examples
An administrator monitors lm1000scurrentValueOffsetNomMonitor against lm1000smajorHighOffsetNomMonitor to catch a laser transmitter drifting out of tolerance in an HFC headend.
What Can Be Monitored
- gx2Lm1000s laser transmitter telemetry vs. alarm thresholds
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Lm1000s | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapLM1000SConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.31.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapLM1000SConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.31.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapLM1000SfanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.3 | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLM1000SModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.4 | This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLM1000SomiOffsetAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.5 | This trap is issued when the OMI Offset goes out of range. | ||
| NTF trapLM1000StecCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.6 | This trap is issued when the TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLM1000SLaserCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.7 | This trap is issued when the Laser Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLM1000SLaserTempAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.8 | This trap is issued when the Laser Temp parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLM1000SLaserPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.9 | This trap is issued when the Laser Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLM1000SFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.10 | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| NTF trapLM1000SBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.11 | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| NTF trapLM1000SAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.12 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapLM1000SFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.13 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapLM1000SCalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.14 | This trap is issued when the Cal Data CRC is incorrect. | ||
| NTF trapLM1000SResetFacDefault | 1.3.6.1.4.1.1166.6.1.2.31.0.15 | This trap is issued when the LM1000S resets to factory defaults | ||
| NTF trapLM1000SUserRFOffAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.16 | This trap is issued when the the User RF is turned off. | ||
| NTF trapLM1000SUserOpticalOffAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.17 | This trap is issued when the User Optical Power is turned off. | ||
| NTF trapLM1000SUserSBSOffAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.18 | This trap is issued when the User SBS is turned off. | ||
| NTF trapLM1000SRFInputAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.19 | This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLM1000SRFOverloadAlarm | 1.3.6.1.4.1.1166.6.1.2.31.0.20 | This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| gx2Lm1000sDescriptor | 1.3.6.1.4.1.1166.6.1.2.31.1 | |||
| gx2Lm1000sAnalogTable | 1.3.6.1.4.1.1166.6.1.2.31.2 | not-accessible | This table contains gx2Lm1000s specific parameters with nominal and current values. | |
| gx2Lm1000sAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.31.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2Lm1000sAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.31.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR lm1000slabelOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.31.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Offset Monitor Analog parameter. |
| STR lm1000suomOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.31.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. The unit of measure for this parameter is dB |
| FLO lm1000smajorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.31.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO lm1000smajorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.31.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO lm1000sminorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.31.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO lm1000sminorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.31.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO lm1000scurrentValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.31.2.1.8 | Float | read-only | The value of this object provides the Current value of the Offset Monitor Power Analog parameter. |
| INT lm1000sstateFlagOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.31.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Offset Monitor Power Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO lm1000sminValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.31.2.1.10 | Float | read-only | The value of this object provides the minimum value the Offset Monitor Power Analog parameter can achive. |
| FLO lm1000smaxValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.31.2.1.11 | Float | read-only | The value of this object provides the maximum value the Offset Monitor Power Analog parameter can achive. |
| INT lm1000salarmStateOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.31.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Offset Monitor Power Analog parameter. |
| STR lm1000slabelLaserPower | 1.3.6.1.4.1.1166.6.1.2.31.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Laser Optical Power Analog parameter. |
| STR lm1000suomLaserPower | 1.3.6.1.4.1.1166.6.1.2.31.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Optical Power Analog parameter. The unit of measure for this parameter is dBm |
| FLO lm1000smajorHighLaserPower | 1.3.6.1.4.1.1166.6.1.2.31.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Optical Power Analog parameter. |
| FLO lm1000smajorLowLaserPower | 1.3.6.1.4.1.1166.6.1.2.31.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Optical Power Analog parameter. |
| FLO lm1000sminorHighLaserPower | 1.3.6.1.4.1.1166.6.1.2.31.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO lm1000sminorLowLaserPower | 1.3.6.1.4.1.1166.6.1.2.31.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO lm1000scurrentValueLaserPower | 1.3.6.1.4.1.1166.6.1.2.31.2.1.19 | Float | read-only | The value of this object provides the Current value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm1000sstateFlagLaserPower | 1.3.6.1.4.1.1166.6.1.2.31.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Laser Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO lm1000sminValueLaserPower | 1.3.6.1.4.1.1166.6.1.2.31.2.1.21 | Float | read-only | The value of this object provides the minimum value the Laser Optical Power Analog parameter can achive. |
| FLO lm1000smaxValueLaserPower | 1.3.6.1.4.1.1166.6.1.2.31.2.1.22 | Float | read-only | The value of this object provides the maximum value the Laser Optical Power Analog parameter can achive. |
| INT lm1000salarmStateLaserPower | 1.3.6.1.4.1.1166.6.1.2.31.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Optical Power Analog parameter. |
| STR lm1000slabelLaserTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Laser Temperature Analog parameter. |
| STR lm1000suomLaserTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. The unit of measure for this parameter is degrees C |
| FLO lm1000smajorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. |
| FLO lm1000smajorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. |
| FLO lm1000sminorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. |
| FLO lm1000sminorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. |
| FLO lm1000scurrentValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.30 | Float | read-only | The value of this object provides the Current value of the Laser Temperature Analog parameter. |
| INT lm1000sstateFlagLaserTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Laser Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO lm1000sminValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.32 | Float | read-only | The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. |
| FLO lm1000smaxValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.33 | Float | read-only | The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. |
| INT lm1000salarmStateLaserTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. |
| STR lm1000slabelLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| STR lm1000suomLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Bias Current Analog parameter. The unit of measure for this parameter is mA |
| FLO lm1000smajorHighLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Bias Current Analog parameter. |
| FLO lm1000smajorLowLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Bias Current Analog parameter. |
| FLO lm1000sminorHighLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO lm1000sminorLowLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO lm1000scurrentValueLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.41 | Float | read-only | The value of this object provides the Current value of the Laser Bias Current Analog parameter. |
| INT lm1000sstateFlagLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Laser Bias Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO lm1000sminValueLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.43 | Float | read-only | The value of this object provides the minimum value the Laser Bias Current Analog parameter can achive. |
| FLO lm1000smaxValueLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.44 | Float | read-only | The value of this object provides the maximum value the Laser Bias Current Analog parameter can achive. |
| INT lm1000salarmStateLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Bias Current Analog parameter. |
| STR lm1000slabelTecCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.46 | DisplayString | read-only | The value of this object provides the label of the TEC Current Analog parameter. |
| STR lm1000suomTecCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the TEC Current Analog parameter. The unit of measure for this parameter is mA |
| FLO lm1000smajorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. |
| FLO lm1000smajorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. |
| FLO lm1000sminorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO lm1000sminorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO lm1000scurrentValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.52 | Float | read-only | The value of this object provides the Current value of the TEC Current Analog parameter. |
| INT lm1000sstateFlagTecCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.53 | INTEGER | read-only | The value of this object provides the state of the TEC Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO lm1000sminValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.54 | Float | read-only | The value of this object provides the minimum value the TEC Current Analog parameter can achive. |
| FLO lm1000smaxValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.55 | Float | read-only | The value of this object provides the maximum value the TEC Current Analog parameter can achive. |
| INT lm1000salarmStateTecCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| STR lm1000slabelModTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR lm1000suomModTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. The unit of measure for this parameter is degrees C |
| FLO lm1000smajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. |
| FLO lm1000smajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. |
| FLO lm1000sminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. |
| FLO lm1000sminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. |
| FLO lm1000scurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.63 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. |
| INT lm1000sstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO lm1000sminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.65 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. |
| FLO lm1000smaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.66 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. |
| INT lm1000salarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.31.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR lm1000slabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR lm1000suomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. The unit of measure for this parameter is mA |
| FLO lm1000smajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. |
| FLO lm1000smajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. |
| FLO lm1000sminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO lm1000sminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO lm1000scurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.74 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. |
| INT lm1000sstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO lm1000sminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.76 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achive. |
| FLO lm1000smaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.77 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achive. |
| INT lm1000salarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.31.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| gx2Lm1000sDigitalTable | 1.3.6.1.4.1.1166.6.1.2.31.3 | not-accessible | This table contains gx2Lm1000sm specific parameters with nominal and current values. | |
| gx2Lm1000sDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.31.3.2 | not-accessible | This list contains digital parameters and descriptions. | |
| INT gx2Lm1000sDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.31.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR lm1000slabelRfInput | 1.3.6.1.4.1.1166.6.1.2.31.3.2.2 | DisplayString | read-only | The value of this object provides the label of the RF Input Control Digital parameter. |
| STR lm1000senumRfInput | 1.3.6.1.4.1.1166.6.1.2.31.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT lm1000svalueRfInput | 1.3.6.1.4.1.1166.6.1.2.31.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT lm1000sstateflagRfInput | 1.3.6.1.4.1.1166.6.1.2.31.3.2.5 | INTEGER | read-only | The value of this object provides the state of the RF Input Control Digital parameter. (1-hidden 2-read-only, 3-updateable). |
| STR lm1000slabelOptOutput | 1.3.6.1.4.1.1166.6.1.2.31.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Optical Output Control Digital parameter. |
| STR lm1000senumOptOutput | 1.3.6.1.4.1.1166.6.1.2.31.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT lm1000svalueOptOutput | 1.3.6.1.4.1.1166.6.1.2.31.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT lm1000sstateflagOptOutput | 1.3.6.1.4.1.1166.6.1.2.31.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR lm1000slabelAttnSetting | 1.3.6.1.4.1.1166.6.1.2.31.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Attenuation Setting Digital parameter. |
| STR lm1000senumAttnSetting | 1.3.6.1.4.1.1166.6.1.2.31.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT lm1000svalueAttnSetting | 1.3.6.1.4.1.1166.6.1.2.31.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. Each step indicates a .5dB change in attenuation Its range is 0 to 15 dB |
| INT lm1000sstateflagAttnSetting | 1.3.6.1.4.1.1166.6.1.2.31.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR lm1000slabelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.31.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Factory Default Digital parameter. |
| STR lm1000senumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.31.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.. |
| INT lm1000svalueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.31.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. Return value is meaningless |
| INT lm1000sstateflagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.31.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| gx2Lm1000sStatusTable | 1.3.6.1.4.1.1166.6.1.2.31.4 | not-accessible | This table contains gx2Lm1000s specific parameters with nominal and current values. | |
| gx2Lm1000sStatusEntry | 1.3.6.1.4.1.1166.6.1.2.31.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2Lm1000sStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.31.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR lm1000slabelBoot | 1.3.6.1.4.1.1166.6.1.2.31.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT lm1000svalueBoot | 1.3.6.1.4.1.1166.6.1.2.31.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT lm1000sstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.31.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR lm1000slabelFlash | 1.3.6.1.4.1.1166.6.1.2.31.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT lm1000svalueFlash | 1.3.6.1.4.1.1166.6.1.2.31.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT lm1000sstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.31.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR lm1000slabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.31.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT lm1000svalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.31.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT lm1000sstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.31.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR lm1000slabelLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.31.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Laser Data CRC Status parameter. |
| INT lm1000svalueLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.31.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT lm1000sstateflagLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.31.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR lm1000slabelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.31.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT lm1000svalueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.31.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT lm1000sstateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.31.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR lm1000slabelRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.31.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT lm1000svalueRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.31.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT lm1000sstateflagRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.31.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| gx2Lm1000sFactoryTable | 1.3.6.1.4.1.1166.6.1.2.31.5 | not-accessible | This table contains gx2Lm1000s specific parameters with nominal and current values. | |
| gx2Lm1000sFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.31.5.4 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2Lm1000sFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.31.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT lm1000sbootControlByte | 1.3.6.1.4.1.1166.6.1.2.31.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT lm1000sbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.31.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail) |
| INT lm1000sbank1CRC | 1.3.6.1.4.1.1166.6.1.2.31.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. The display formate for the data is Hex. |
| INT lm1000sbank2CRC | 1.3.6.1.4.1.1166.6.1.2.31.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1.The display formate for the data is Hex. |
| INT lm1000sprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.31.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT lm1000sfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.31.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT lm1000scalculateCRC | 1.3.6.1.4.1.1166.6.1.2.31.5.4.8 | INTEGER | read-only | This object indicates which of the Enums will have the CRC calculated. |
| INT lm1000shourMeter | 1.3.6.1.4.1.1166.6.1.2.31.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT lm1000sflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.31.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT lm1000sflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.31.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR lm1000sflashBankARev | 1.3.6.1.4.1.1166.6.1.2.31.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. The rev is 2 characters. |
| STR lm1000sflashBankBRev | 1.3.6.1.4.1.1166.6.1.2.31.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. The rev is 2 characters. |
RFC description
Vendor-private MIB for OMNI GX2 LM1000s system management.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (gx2Lm1000s 1000-series laser transmitter module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.