OMNI-gx2Rx200BX4-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2Rx200BX4 FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "1" Oct 3, 2007 Initial Release --REVISION "2" May 5, 2009 Adds Burst mode to Module configuration OID --REVISION "3" Sept 10, 2009 Adds Optical power bad traps --DESCRIPTION -- Initial revision derived from RX200BX2 -- OMNISTAR Quad (High Density) Return Path Receiver Module MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2Rx200BX4 Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Rx200BX4 device type. -- These parameters are common across all network elements -- from gx2Rx200BX4 device type. -- -- The gx2Rx200BX4 Network Elements subgroup is -- a list of gx2Rx200BX4 type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Rx200BX4TableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2Rx200BX4 type. -- -- Both groups are mandatory for management of gx2Rx200BX4 devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) U32Data ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2Rx200BX4 Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Rx200BX4 device type. -- These parameters are common across all network elements -- from gx2Rx200BX4 device type. gx2Rx200BX4Descriptor OBJECT IDENTIFIER ::= {gx2Rx200BX4 1} --***************************************************************************** -- gx2Rx200BX4 Table -- Contains a list of all gx2Rx200BX4 type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Rx200BX4TableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2Rx200BX4 type. gx2Rx200BX4AnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx200BX4AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx200BX4 specific parameters with nominal and current values." ::= { gx2Rx200BX4 2 } gx2Rx200BX4AnalogEntry OBJECT-TYPE SYNTAX Gx2Rx200BX4AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2Rx200BX4AnalogTableIndex } ::= { gx2Rx200BX4AnalogTable 1} --*********************************************************************** gx2Rx200BX4DigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx200BX4DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx200BX4 specific parameters with nominal and current values." ::= { gx2Rx200BX4 3 } gx2Rx200BX4DigitalEntry OBJECT-TYPE SYNTAX Gx2Rx200BX4DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2Rx200BX4DigitalTableIndex } ::= { gx2Rx200BX4DigitalTable 2} --*********************************************************************** gx2Rx200BX4StatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx200BX4StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx200BX4 specific parameters with nominal and current values." ::= { gx2Rx200BX4 4 } gx2Rx200BX4StatusEntry OBJECT-TYPE SYNTAX Gx2Rx200BX4StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2Rx200BX4StatusTableIndex } ::= { gx2Rx200BX4StatusTable 3} --*********************************************************************** gx2Rx200BX4FactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx200BX4FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx200BX4 specific parameters with nominal and current values." ::= { gx2Rx200BX4 5 } gx2Rx200BX4FactoryEntry OBJECT-TYPE SYNTAX Gx2Rx200BX4FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2Rx200BX4FactoryTableIndex } ::= { gx2Rx200BX4FactoryTable 4} --*********************************************************************** --MM Rx200BX4AnalogTableIndex Gx2Rx200BX4AnalogEntry ::= SEQUENCE { gx2Rx200BX4AnalogTableIndex INTEGER, -- Analog Parameters rx4labelOptPowerOne DisplayString (SIZE (0..80)), rx4uomOptPowerOne DisplayString (SIZE (0..80)), rx4majorHighOptPowerOne Float, rx4majorLowOptPowerOne Float, rx4minorHighOptPowerOne Float, rx4minorLowOptPowerOne Float, rx4currentValueOptPowerOne Float, rx4stateFlagOptPowerOne INTEGER, rx4minValueOptPowerOne Float, rx4maxValueOptPowerOne Float, rx4alarmStateOptPowerOne INTEGER, rx4labelOptPowerTwo DisplayString (SIZE (0..80)), rx4uomOptPowerTwo DisplayString (SIZE (0..80)), rx4majorHighOptPowerTwo Float, rx4majorLowOptPowerTwo Float, rx4minorHighOptPowerTwo Float, rx4minorLowOptPowerTwo Float, rx4currentValueOptPowerTwo Float, rx4stateFlagOptPowerTwo INTEGER, rx4minValueOptPowerTwo Float, rx4maxValueOptPowerTwo Float, rx4alarmStateOptPowerTwo INTEGER, rx4labelOptPowerThree DisplayString (SIZE (0..80)), rx4uomOptPowerThree DisplayString (SIZE (0..80)), rx4majorHighOptPowerThree Float, rx4majorLowOptPowerThree Float, rx4minorHighOptPowerThree Float, rx4minorLowOptPowerThree Float, rx4currentValueOptPowerThree Float, rx4stateFlagOptPowerThree INTEGER, rx4minValueOptPowerThree Float, rx4maxValueOptPowerThree Float, rx4alarmStateOptPowerThree INTEGER, rx4labelOptPowerFour DisplayString (SIZE (0..80)), rx4uomOptPowerFour DisplayString (SIZE (0..80)), rx4majorHighOptPowerFour Float, rx4majorLowOptPowerFour Float, rx4minorHighOptPowerFour Float, rx4minorLowOptPowerFour Float, rx4currentValueOptPowerFour Float, rx4stateFlagOptPowerFour INTEGER, rx4minValueOptPowerFour Float, rx4maxValueOptPowerFour Float, rx4alarmStateOptPowerFour INTEGER, rx4labelModTemp DisplayString (SIZE (0..80)), rx4uomModTemp DisplayString (SIZE (0..80)), rx4majorHighModTemp Float, rx4majorLowModTemp Float, rx4minorHighModTemp Float, rx4minorLowModTemp Float, rx4currentValueModTemp Float, rx4stateFlagModTemp INTEGER, rx4minValueModTemp Float, rx4maxValueModTemp Float, rx4alarmStateModTemp INTEGER, rx4labelFanCurrent DisplayString (SIZE (0..80)), rx4uomFanCurrent DisplayString (SIZE (0..80)), rx4majorHighFanCurrent Float, rx4majorLowFanCurrent Float, rx4minorHighFanCurrent Float, rx4minorLowFanCurrent Float, rx4currentValueFanCurrent Float, rx4stateFlagFanCurrent INTEGER, rx4minValueFanCurrent Float, rx4maxValueFanCurrent Float, rx4alarmStateFanCurrent INTEGER, rx4label12Volt DisplayString (SIZE (0..80)), rx4uom12Volt DisplayString (SIZE (0..80)), rx4majorHigh12Volt Float, rx4majorLow12Volt Float, rx4minorHigh12Volt Float, rx4minorLow12Volt Float, rx4currentValue12Volt Float, rx4stateFlag12Volt INTEGER, rx4minValue12Volt Float, rx4maxValue12Volt Float, rx4alarmState12Volt INTEGER } -- **************** Digital Parameters *********************** Gx2Rx200BX4DigitalEntry ::= SEQUENCE { gx2Rx200BX4DigitalTableIndex INTEGER, rx4labelModeOne DisplayString (SIZE (0..80)), rx4valueModeOne INTEGER, rx4enumModeOne DisplayString (SIZE (0..80)), rx4stateFlagModeOne INTEGER, rx4labelWavelengthOne DisplayString (SIZE (0..80)), rx4valueWavelengthOne INTEGER, rx4enumWavelengthOne DisplayString (SIZE (0..80)), rx4stateFlagWavelengthOne INTEGER, rx4labelAttnSettingOne DisplayString (SIZE (0..80)), rx4valueAttnSettingOne INTEGER, rx4enumAttnSettingOne DisplayString (SIZE (0..80)), rx4stateFlagAttnSettingOne INTEGER, rx4labelSwModeSettingOne DisplayString (SIZE (0..80)), rx4valueSwModeSettingOne INTEGER, rx4enumSwModeSettingOne DisplayString (SIZE (0..80)), rx4stateFlagSwModeSettingOne INTEGER, rx4labelSwModeThresholdOne DisplayString (SIZE (0..80)), rx4valueSwModeThresholdOne INTEGER, rx4enumSwModeThresholdOne DisplayString (SIZE (0..80)), rx4stateFlagSwModeThresholdOne INTEGER, rx4labelModeTwo DisplayString (SIZE (0..80)), rx4valueModeTwo INTEGER, rx4enumModeTwo DisplayString (SIZE (0..80)), rx4stateFlagModeTwo INTEGER, rx4labelWavelengthTwo DisplayString (SIZE (0..80)), rx4valueWavelengthTwo INTEGER, rx4enumWavelengthTwo DisplayString (SIZE (0..80)), rx4stateFlagWavelengthTwo INTEGER, rx4labelAttnSettingTwo DisplayString (SIZE (0..80)), rx4valueAttnSettingTwo INTEGER, rx4enumAttnSettingTwo DisplayString (SIZE (0..80)), rx4stateFlagAttnSettingTwo INTEGER, rx4labelSwModeSettingTwo DisplayString (SIZE (0..80)), rx4valueSwModeSettingTwo INTEGER, rx4enumSwModeSettingTwo DisplayString (SIZE (0..80)), rx4stateFlagSwModeSettingTwo INTEGER, rx4labelSwModeThresholdTwo DisplayString (SIZE (0..80)), rx4valueSwModeThresholdTwo INTEGER, rx4enumSwModeThresholdTwo DisplayString (SIZE (0..80)), rx4stateFlagSwModeThresholdTwo INTEGER, rx4labelModeThree DisplayString (SIZE (0..80)), rx4valueModeThree INTEGER, rx4enumModeThree DisplayString (SIZE (0..80)), rx4stateFlagModeThree INTEGER, rx4labelWavelengthThree DisplayString (SIZE (0..80)), rx4valueWavelengthThree INTEGER, rx4enumWavelengthThree DisplayString (SIZE (0..80)), rx4stateFlagWavelengthThree INTEGER, rx4labelAttnSettingThree DisplayString (SIZE (0..80)), rx4valueAttnSettingThree INTEGER, rx4enumAttnSettingThree DisplayString (SIZE (0..80)), rx4stateFlagAttnSettingThree INTEGER, rx4labelSwModeSettingThree DisplayString (SIZE (0..80)), rx4valueSwModeSettingThree INTEGER, rx4enumSwModeSettingThree DisplayString (SIZE (0..80)), rx4stateFlagSwModeSettingThree INTEGER, rx4labelSwModeThresholdThree DisplayString (SIZE (0..80)), rx4valueSwModeThresholdThree INTEGER, rx4enumSwModeThresholdThree DisplayString (SIZE (0..80)), rx4stateFlagSwModeThresholdThree INTEGER, rx4labelModeFour DisplayString (SIZE (0..80)), rx4valueModeFour INTEGER, rx4enumModeFour DisplayString (SIZE (0..80)), rx4stateFlagModeFour INTEGER, rx4labelWavelengthFour DisplayString (SIZE (0..80)), rx4valueWavelengthFour INTEGER, rx4enumWavelengthFour DisplayString (SIZE (0..80)), rx4stateFlagWavelengthFour INTEGER, rx4labelAttnSettingFour DisplayString (SIZE (0..80)), rx4valueAttnSettingFour INTEGER, rx4enumAttnSettingFour DisplayString (SIZE (0..80)), rx4stateFlagAttnSettingFour INTEGER, rx4labelSwModeSettingFour DisplayString (SIZE (0..80)), rx4valueSwModeSettingFour INTEGER, rx4enumSwModeSettingFour DisplayString (SIZE (0..80)), rx4stateFlagSwModeSettingFour INTEGER, rx4labelSwModeThresholdFour DisplayString (SIZE (0..80)), rx4valueSwModeThresholdFour INTEGER, rx4enumSwModeThresholdFour DisplayString (SIZE (0..80)), rx4stateFlagSwModeThresholdFour INTEGER, rx4labelModuleConfig DisplayString (SIZE (0..80)), rx4valueModuleConfig INTEGER, rx4enumModuleConfig DisplayString (SIZE (0..80)), rx4stateFlagModuleConfig INTEGER, rx4labelRevertTime DisplayString (SIZE (0..80)), rx4valueRevertTime INTEGER, rx4enumRevertTime DisplayString (SIZE (0..80)), rx4stateFlagRevertTime INTEGER, rx4labelTestPointSelect DisplayString (SIZE (0..80)), rx4valueTestPointSelect INTEGER, rx4enumTestPointSelect DisplayString (SIZE (0..80)), rx4stateFlagTestPointSelect INTEGER, rx4labelFactoryDefault DisplayString (SIZE (0..80)), rx4valueFactoryDefault INTEGER, rx4enumFactoryDefault DisplayString (SIZE (0..80)), rx4stateFlagFactoryDefault INTEGER } -- **************** Status Parameters ************************************ Gx2Rx200BX4StatusEntry ::= SEQUENCE { gx2Rx200BX4StatusTableIndex INTEGER, rx4labelBoot DisplayString (SIZE (0..80)), rx4valueBoot INTEGER, rx4stateflagBoot INTEGER, rx4labelFlash DisplayString (SIZE (0..80)), rx4valueFlash INTEGER, rx4stateflagFlash INTEGER, rx4labelFactoryDataCRC DisplayString (SIZE (0..80)), rx4valueFactoryDataCRC INTEGER, rx4stateflagFactoryDataCRC INTEGER, rx4labelAlarmDataCRC DisplayString (SIZE (0..80)), rx4valueAlarmDataCRC INTEGER, rx4stateflagAlarmDataCRC INTEGER, rx4labelCalibrationDataCRC DisplayString (SIZE (0..80)), rx4valueCalibrationDataCRC INTEGER, rx4stateflagCalibrationDataCRC INTEGER, rx4labelHW DisplayString (SIZE (0..80)), rx4valueHW INTEGER, rx4stateflagHW INTEGER, rx4labelOptSigOne DisplayString (SIZE (0..80)), rx4valueOptSigOne INTEGER, rx4stateflagOptSigOne INTEGER, rx4labelOptSigTwo DisplayString (SIZE (0..80)), rx4valueOptSigTwo INTEGER, rx4stateflagOptSigTwo INTEGER, rx4labelOptSigThree DisplayString (SIZE (0..80)), rx4valueOptSigThree INTEGER, rx4stateflagOptSigThree INTEGER, rx4labelOptSigFour DisplayString (SIZE (0..80)), rx4valueOptSigFour INTEGER, rx4stateflagOptSigFour INTEGER, rx4labelBackupCable DisplayString (SIZE (0..80)), rx4valueBackupCable INTEGER, rx4stateflagBackupCable INTEGER } -- **************** Factory Parameters ************************************* Gx2Rx200BX4FactoryEntry ::= SEQUENCE { gx2Rx200BX4FactoryTableIndex INTEGER, rx4bootControlByte INTEGER, rx4bootStatusByte INTEGER, rx4bank0CRC INTEGER, rx4bank1CRC INTEGER, rx4prgEEPROMByte INTEGER, rx4factoryCRC INTEGER, rx4calculateCRC INTEGER, rx4hourMeter INTEGER, rx4flashPrgCntA INTEGER, rx4flashPrgCntB INTEGER, rx4fwRev0 DisplayString (SIZE (0..80)), rx4fwRev1 DisplayString (SIZE (0..80)) } -- **************** Hold Time Parameters ************************************* -- Gx2Rx200BX4HoldTimeEntry ::= SEQUENCE -- { -- gx2Rx200BX4HoldTimeTableIndex INTEGER, -- gx2Rx200BX4HoldTimeSpecIndex INTEGER, -- gx2Rx200BX4HoldTimeData INTEGER -- } -- -- ************** Analog Parameters **************************** gx2Rx200BX4AnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rx200BX4AnalogEntry 1} -- New Parameter rx4labelOptPowerOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2Rx200BX4AnalogEntry 2} rx4uomOptPowerOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2Rx200BX4AnalogEntry 3} rx4majorHighOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 4} rx4majorLowOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 5} rx4minorHighOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 6} rx4minorLowOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 7} rx4currentValueOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 8} rx4stateFlagOptPowerOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4AnalogEntry 9} rx4minValueOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 10} rx4maxValueOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 11} rx4alarmStateOptPowerOne OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2Rx200BX4AnalogEntry 12} -- New Parameter rx4labelOptPowerTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2Rx200BX4AnalogEntry 13} rx4uomOptPowerTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2Rx200BX4AnalogEntry 14} rx4majorHighOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 15} rx4majorLowOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 16} rx4minorHighOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 17} rx4minorLowOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 18} rx4currentValueOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 19} rx4stateFlagOptPowerTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4AnalogEntry 20} rx4minValueOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 21} rx4maxValueOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 22} rx4alarmStateOptPowerTwo OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2Rx200BX4AnalogEntry 23} -- New Parameter rx4labelOptPowerThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2Rx200BX4AnalogEntry 24} rx4uomOptPowerThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2Rx200BX4AnalogEntry 25} rx4majorHighOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 26} rx4majorLowOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 27} rx4minorHighOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 28} rx4minorLowOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 29} rx4currentValueOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 30} rx4stateFlagOptPowerThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4AnalogEntry 31} rx4minValueOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 32} rx4maxValueOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 33} rx4alarmStateOptPowerThree OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2Rx200BX4AnalogEntry 34} -- New Parameter rx4labelOptPowerFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2Rx200BX4AnalogEntry 35} rx4uomOptPowerFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2Rx200BX4AnalogEntry 36} rx4majorHighOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 37} rx4majorLowOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 38} rx4minorHighOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 39} rx4minorLowOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 40} rx4currentValueOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 41} rx4stateFlagOptPowerFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4AnalogEntry 42} rx4minValueOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 43} rx4maxValueOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 44} rx4alarmStateOptPowerFour OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2Rx200BX4AnalogEntry 45} -- New Parameter rx4labelModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2Rx200BX4AnalogEntry 46} rx4uomModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2Rx200BX4AnalogEntry 47} rx4majorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 48} rx4majorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 49} rx4minorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 50} rx4minorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 51} rx4currentValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 52} rx4stateFlagModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4AnalogEntry 53} rx4minValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 54} rx4maxValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 55} rx4alarmStateModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2Rx200BX4AnalogEntry 56} -- New Parameter rx4labelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2Rx200BX4AnalogEntry 57} rx4uomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter." ::= { gx2Rx200BX4AnalogEntry 58} rx4majorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 59} rx4majorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 60} rx4minorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 61} rx4minorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 62} rx4currentValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 63} rx4stateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4AnalogEntry 64} rx4minValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 65} rx4maxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 66} rx4alarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2Rx200BX4AnalogEntry 67} -- New Parameter rx4label12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the 12v Current Analog parameter." ::= { gx2Rx200BX4AnalogEntry 68} rx4uom12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v Current Analog parameter." ::= { gx2Rx200BX4AnalogEntry 69} rx4majorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 70} rx4majorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 71} rx4minorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 72} rx4minorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 73} rx4currentValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 74} rx4stateFlag12Volt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4AnalogEntry 75} rx4minValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 76} rx4maxValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx200BX4AnalogEntry 77} rx4alarmState12Volt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the 12v Current Analog parameter." ::= { gx2Rx200BX4AnalogEntry 78} -- ************************ Digital parameters ********************************** gx2Rx200BX4DigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rx200BX4DigitalEntry 1} -- New parameter rx4labelModeOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Mode Digital parameter." ::= { gx2Rx200BX4DigitalEntry 2} rx4enumModeOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 3} rx4valueModeOne OBJECT-TYPE SYNTAX INTEGER { off(1), manual(2), agc(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 4} rx4stateFlagModeOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 5} -- New parameter rx4labelWavelengthOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter." ::= { gx2Rx200BX4DigitalEntry 6} rx4enumWavelengthOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 7} rx4valueWavelengthOne OBJECT-TYPE SYNTAX INTEGER { nM1270(1), nM1290(2), nM1310(3), nM1330(4), nM1350(5), nM1370(6), nM1390(7), nM1410(8), nM1430(9), nM1450(10), nM1470(11), nM1490(12), nM1510(13), nM1530(14), nM1550(15), nM1570(16), nM1590(17), nM1610(18) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 8} rx4stateFlagWavelengthOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 9} -- New parameter rx4labelAttnSettingOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter." ::= { gx2Rx200BX4DigitalEntry 10} rx4enumAttnSettingOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 11} rx4valueAttnSettingOne OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db" ::= { gx2Rx200BX4DigitalEntry 12} rx4stateFlagAttnSettingOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 13} -- New parameter rx4labelSwModeSettingOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter." ::= { gx2Rx200BX4DigitalEntry 14} rx4enumSwModeSettingOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 15} rx4valueSwModeSettingOne OBJECT-TYPE SYNTAX INTEGER { off(1), alarm-only(2), alarm-and-switch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 16} rx4stateFlagSwModeSettingOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 17} -- New parameter rx4labelSwModeThresholdOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter." ::= { gx2Rx200BX4DigitalEntry 18} rx4enumSwModeThresholdOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 19} rx4valueSwModeThresholdOne OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db" ::= { gx2Rx200BX4DigitalEntry 20} rx4stateFlagSwModeThresholdOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 21} -- New parameter rx4labelModeTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Mode Digital parameter." ::= { gx2Rx200BX4DigitalEntry 22} rx4enumModeTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 23} rx4valueModeTwo OBJECT-TYPE SYNTAX INTEGER { off(1), manual(2), agc(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 24} rx4stateFlagModeTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 25} -- New parameter rx4labelWavelengthTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter." ::= { gx2Rx200BX4DigitalEntry 26} rx4enumWavelengthTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 27} rx4valueWavelengthTwo OBJECT-TYPE SYNTAX INTEGER { nM1270(1), nM1290(2), nM1310(3), nM1330(4), nM1350(5), nM1370(6), nM1390(7), nM1410(8), nM1430(9), nM1450(10), nM1470(11), nM1490(12), nM1510(13), nM1530(14), nM1550(15), nM1570(16), nM1590(17), nM1610(18) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 28} rx4stateFlagWavelengthTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 29} -- New parameter rx4labelAttnSettingTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter." ::= { gx2Rx200BX4DigitalEntry 30} rx4enumAttnSettingTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 31} rx4valueAttnSettingTwo OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db" ::= { gx2Rx200BX4DigitalEntry 32} rx4stateFlagAttnSettingTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 33} -- New parameter rx4labelSwModeSettingTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter." ::= { gx2Rx200BX4DigitalEntry 34} rx4enumSwModeSettingTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 35} rx4valueSwModeSettingTwo OBJECT-TYPE SYNTAX INTEGER { off(1), alarm-only(2), alarm-and-switch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 36} rx4stateFlagSwModeSettingTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 37} -- New parameter rx4labelSwModeThresholdTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter." ::= { gx2Rx200BX4DigitalEntry 38} rx4enumSwModeThresholdTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 39} rx4valueSwModeThresholdTwo OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db" ::= { gx2Rx200BX4DigitalEntry 40} rx4stateFlagSwModeThresholdTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 41} -- New parameter rx4labelModeThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Mode Digital parameter." ::= { gx2Rx200BX4DigitalEntry 42} rx4enumModeThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 43} rx4valueModeThree OBJECT-TYPE SYNTAX INTEGER { off(1), manual(2), agc(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 44} rx4stateFlagModeThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 45} -- New parameter rx4labelWavelengthThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter." ::= { gx2Rx200BX4DigitalEntry 46} rx4enumWavelengthThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 47} rx4valueWavelengthThree OBJECT-TYPE SYNTAX INTEGER { nM1270(1), nM1290(2), nM1310(3), nM1330(4), nM1350(5), nM1370(6), nM1390(7), nM1410(8), nM1430(9), nM1450(10), nM1470(11), nM1490(12), nM1510(13), nM1530(14), nM1550(15), nM1570(16), nM1590(17), nM1610(18) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 48} rx4stateFlagWavelengthThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 49} -- New parameter rx4labelAttnSettingThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter." ::= { gx2Rx200BX4DigitalEntry 50} rx4enumAttnSettingThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 51} rx4valueAttnSettingThree OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db" ::= { gx2Rx200BX4DigitalEntry 52} rx4stateFlagAttnSettingThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 53} -- New parameter rx4labelSwModeSettingThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter." ::= { gx2Rx200BX4DigitalEntry 54} rx4enumSwModeSettingThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 55} rx4valueSwModeSettingThree OBJECT-TYPE SYNTAX INTEGER { off(1), alarm-only(2), alarm-and-switch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 56} rx4stateFlagSwModeSettingThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 57} -- New parameter rx4labelSwModeThresholdThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter." ::= { gx2Rx200BX4DigitalEntry 58} rx4enumSwModeThresholdThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 59} rx4valueSwModeThresholdThree OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db" ::= { gx2Rx200BX4DigitalEntry 60} rx4stateFlagSwModeThresholdThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 61} -- New parameter rx4labelModeFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Mode Digital parameter." ::= { gx2Rx200BX4DigitalEntry 62} rx4enumModeFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 63} rx4valueModeFour OBJECT-TYPE SYNTAX INTEGER { off(1), manual(2), agc(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 64} rx4stateFlagModeFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 65} -- New parameter rx4labelWavelengthFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter." ::= { gx2Rx200BX4DigitalEntry 66} rx4enumWavelengthFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 67} rx4valueWavelengthFour OBJECT-TYPE SYNTAX INTEGER { nM1270(1), nM1290(2), nM1310(3), nM1330(4), nM1350(5), nM1370(6), nM1390(7), nM1410(8), nM1430(9), nM1450(10), nM1470(11), nM1490(12), nM1510(13), nM1530(14), nM1550(15), nM1570(16), nM1590(17), nM1610(18) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 68} rx4stateFlagWavelengthFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 69} -- New parameter rx4labelAttnSettingFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter." ::= { gx2Rx200BX4DigitalEntry 70} rx4enumAttnSettingFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 71} rx4valueAttnSettingFour OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db" ::= { gx2Rx200BX4DigitalEntry 72} rx4stateFlagAttnSettingFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 73} -- New parameter rx4labelSwModeSettingFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter." ::= { gx2Rx200BX4DigitalEntry 74} rx4enumSwModeSettingFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 75} rx4valueSwModeSettingFour OBJECT-TYPE SYNTAX INTEGER { off(1), alarm-only(2), alarm-and-switch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 76} rx4stateFlagSwModeSettingFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 77} -- New parameter rx4labelSwModeThresholdFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter." ::= { gx2Rx200BX4DigitalEntry 78} rx4enumSwModeThresholdFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 79} rx4valueSwModeThresholdFour OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db" ::= { gx2Rx200BX4DigitalEntry 80} rx4stateFlagSwModeThresholdFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 81} -- New parameter rx4labelModuleConfig OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2Rx200BX4DigitalEntry 82} rx4enumModuleConfig OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 83} rx4valueModuleConfig OBJECT-TYPE SYNTAX INTEGER { slave(1), master(2), burst(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 84} rx4stateFlagModuleConfig OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 85} -- New parameter rx4labelRevertTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2Rx200BX4DigitalEntry 86} rx4enumRevertTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 87} rx4valueRevertTime OBJECT-TYPE SYNTAX INTEGER { one-sec(1), ten-sec(2), sixty-sec(3), six-hundred-sec(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 88} rx4stateFlagRevertTime OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 89} -- New parameter rx4labelTestPointSelect OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Test point Select Digital parameter." ::= { gx2Rx200BX4DigitalEntry 90} rx4enumTestPointSelect OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 91} rx4valueTestPointSelect OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), three(3), four(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 92} rx4stateFlagTestPointSelect OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 93} -- New parameter rx4labelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2Rx200BX4DigitalEntry 94} rx4enumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx200BX4DigitalEntry 95} rx4valueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx200BX4DigitalEntry 96} rx4stateFlagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4DigitalEntry 97} --*********** STATUS ***************** gx2Rx200BX4StatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rx200BX4StatusEntry 1} --New Parameter rx4labelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2Rx200BX4StatusEntry 2} rx4valueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx200BX4StatusEntry 3} rx4stateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4StatusEntry 4} --New Parameter rx4labelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2Rx200BX4StatusEntry 5} rx4valueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx200BX4StatusEntry 6} rx4stateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4StatusEntry 7} --New Parameter rx4labelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2Rx200BX4StatusEntry 8} rx4valueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx200BX4StatusEntry 9} rx4stateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4StatusEntry 10} --New Parameter rx4labelAlarmDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data CRC Status parameter." ::= { gx2Rx200BX4StatusEntry 11} rx4valueAlarmDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx200BX4StatusEntry 12} rx4stateflagAlarmDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4StatusEntry 13} --New Parameter rx4labelCalibrationDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Calibration Data CRC Status parameter." ::= { gx2Rx200BX4StatusEntry 14} rx4valueCalibrationDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx200BX4StatusEntry 15} rx4stateflagCalibrationDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4StatusEntry 16} --New Parameter rx4labelHW OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Hardware Status parameter." ::= { gx2Rx200BX4StatusEntry 17} rx4valueHW OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx200BX4StatusEntry 18} rx4stateflagHW OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4StatusEntry 19} --New Parameter rx4labelOptSigOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Signal Status parameter." ::= { gx2Rx200BX4StatusEntry 20} rx4valueOptSigOne OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx200BX4StatusEntry 21} rx4stateflagOptSigOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4StatusEntry 22} --New Parameter rx4labelOptSigTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Signal Status parameter." ::= { gx2Rx200BX4StatusEntry 23} rx4valueOptSigTwo OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx200BX4StatusEntry 24} rx4stateflagOptSigTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4StatusEntry 25} --New Parameter rx4labelOptSigThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Signal Status parameter." ::= { gx2Rx200BX4StatusEntry 26} rx4valueOptSigThree OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx200BX4StatusEntry 27} rx4stateflagOptSigThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4StatusEntry 28} --New Parameter rx4labelOptSigFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Signal Status parameter." ::= { gx2Rx200BX4StatusEntry 29} rx4valueOptSigFour OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx200BX4StatusEntry 30} rx4stateflagOptSigFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4StatusEntry 31} --New Parameter rx4labelBackupCable OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Backup Cable Status parameter." ::= { gx2Rx200BX4StatusEntry 32} rx4valueBackupCable OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx200BX4StatusEntry 33} rx4stateflagBackupCable OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx200BX4StatusEntry 34} -- ************ FACTORY DATA **************** gx2Rx200BX4FactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rx200BX4FactoryEntry 1} rx4bootControlByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2Rx200BX4FactoryEntry 2} rx4bootStatusByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot" ::= { gx2Rx200BX4FactoryEntry 3} rx4bank0CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0." ::= { gx2Rx200BX4FactoryEntry 4} rx4bank1CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1." ::= { gx2Rx200BX4FactoryEntry 5} rx4prgEEPROMByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2Rx200BX4FactoryEntry 6} rx4factoryCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2Rx200BX4FactoryEntry 7} rx4calculateCRC OBJECT-TYPE SYNTAX INTEGER { factory(1), calibration(2), alarm(3), tempComp(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which of the Emnums will have the CRC calculated." ::= { gx2Rx200BX4FactoryEntry 8} rx4hourMeter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2Rx200BX4FactoryEntry 9} rx4flashPrgCntA OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times the flash has been programmed on side A." ::= { gx2Rx200BX4FactoryEntry 10} rx4flashPrgCntB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times the flash has been programmed on side B." ::= { gx2Rx200BX4FactoryEntry 11} rx4fwRev0 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Revision of the firmware stores in bank 0." ::= { gx2Rx200BX4FactoryEntry 12} rx4fwRev1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Revision of the firmware stores in bank 1." ::= { gx2Rx200BX4FactoryEntry 13} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** -- ************************************************************************** -- Rx200BX4 Module traps -- ************************************************************************** trapRx200BX4ConfigChangeInteger TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapRx200BX4ConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapRx200BX4OpticalPower1Alarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Receiver's channel 1 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapRx200BX4OpticalPower2Alarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Receiver's channel 2 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapRx200BX4OpticalPower3Alarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Receiver's channel 3 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 5 trapRx200BX4OpticalPower4Alarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Receiver's channel 4 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 6 trapRx200BX4ModuleTemperatureAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 7 trapRx200BX4FanCurrentAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 8 trapRx200BX4Plus12CurrentAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 9 trapRx200BX4Boot0Alarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 10 trapRx200BX4Boot1Alarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 11 trapRx200BX4FlashAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 12 trapRx200BX4AlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 13 trapRx200BX4FactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 14 trapRx200BX4CalDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 15 trapRx200BX4DefaultAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 16 trapRx200BX4Mode1Alarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 17 trapRx200BX4Mode2Alarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 18 trapRx200BX4Mode3Alarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 19 trapRx200BX4Mode4Alarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 20 trapRx200BX4Output1SwitchedAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Module's receiver 1 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 21 trapRx200BX4Output2SwitchedAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Module's receiver 2 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 22 trapRx200BX4Output3SwitchedAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Module's receiver 3 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 23 trapRx200BX4Output4SwitchedAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx200BX4 Module's receiver 4 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 24 trapRx200BX4RX1StatusAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when receiver 1 of the Rx200BX4 Module output is turned on or off." ::= 25 trapRx200BX4RX2StatusAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when receiver 2 of the Rx200BX4 Module output is turned on or off." ::= 26 trapRx200BX4RX3StatusAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when receiver 3 of the Rx200BX4 Module output is turned on or off." ::= 27 trapRx200BX4RX4StatusAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when receiver 4 of the Rx200BX4 Module output is turned on or off." ::= 28 trapRx200BX4BackupCableAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the slave receiver loses connection to the master receiver." ::= 29 trapRx200BX4OptPwr1BadAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the receiver 1 optical power level falls below the user set switching threshold." ::= 30 trapRx200BX4OptPwr2BadAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the receiver 2 optical power level falls below the user set switching threshold." ::= 31 trapRx200BX4OptPwr3BadAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the receiver 3 optical power level falls below the user set switching threshold." ::= 32 trapRx200BX4OptPwr4BadAlarm TRAP-TYPE ENTERPRISE gx2Rx200BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the receiver 4 optical power level falls below the user set switching threshold." ::= 33 END